SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna...

7
PRELIMINARY P.U.D. AMENDMENT 347 LUNA DRIVE NASHVILLE , DAVIDSON COUNTY, TN JOB NO.: 18-109-01 SOUTH PERIMETER PARK DRIVE SHEET INDEX COVER P.U.D. BOUNDARY PLAN EXISTING CONDITIONS PLAN SITE LAYOUT AND UTILITY PLAN GRADING AND DRAINAGE PLAN LANDSCAPE ORDINANCE PLAN LANDSCAPE NOTES AND DETAILS PUD CASE NO. 8-68P-001 H T R O N VICINITY MAP DEVELOPMENT SUMMARY Council District Number: 28 Council Member Name: Tanaka Vercher Owner of Record: Bill Tillery 301 S. Perimeter Park Drive, Suite 200 Nashville, TN 37211 PUD Name: South Perimeter Park Drive Case Number: 8-68P-001 Designer: Civil Site Design Group, PLLC 2305 Kline Avenue, Suite 300 Nashville, TN 37211 Phone: (615) 248-9999 Contact: Joe Haddix [email protected] U.S. FEMA FIRM: 47037C0379H (dated April 05, 2017) C0.01 C1.00 C2.00 C3.00 L1.0 L2.0 Purpose Note: The purpose of this plan is to revise the current Planned Unit Development (P.U.D.) to include Parcel 13414000700, ±0.91 acres to allow for an expansion to the existing parking lot. DATE COMMENTS REV. CHKD BY: DRWN BY: JMH JRP 11/28/2018 INITIAL SUBMITTAL JMH JRP 02/20/2019 RESUBMITTAL SITE PARCEL ID: 13414000700 LARGO DR HARDING PLACE HARDING PLACE LINBAR DR WALLACE RD LUNA DR JOHNAKIN DR S. PERIMETER PARK DR PERIMETER HILL DR METROPLEX DR INTERSTATE 24 INTERSTATE 24 OWNER/DEVELOPER 3LS PROPERTIES, LLC 301 S. PERIMETER PARK DRIVE STE. 200 NASHVILLE, TN 37211 PHONE NUMBER: (615) 823-5860 CONTACT: BILL TILLERY E-MAIL: [email protected] ENGINEER CIVIL SITE DESIGN GROUP, P.L.L.C. 2305 KLINE AVENUE, STE. 300 NASHVILLE, TN 37211 PHONE NUMBER: (615) 248-9999 CONTACT: JOE HADDIX, P.E. E-MAIL: [email protected] COUNCIL DISTRICT 28 - TANAKA VERCHER FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

Transcript of SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna...

Page 1: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

PRELIMINARY P.U.D. AMENDMENT

347 LUNA DRIVE

NASHVILLE , DAVIDSON COUNTY, TN

JOB NO.: 18-109-01

SOUTH PERIMETER PARK DRIVE

SHEET INDEX

COVER

P.U.D. BOUNDARY PLAN

EXISTING CONDITIONS PLAN

SITE LAYOUT AND UTILITY PLAN

GRADING AND DRAINAGE PLAN

LANDSCAPE ORDINANCE PLAN

LANDSCAPE NOTES AND DETAILS

PUD CASE NO. 8-68P-001

H

T

R

O

N

VICINITY MAP

DEVELOPMENT SUMMARY

Council District Number: 28

Council Member Name: Tanaka Vercher

Owner of Record: Bill Tillery301 S. Perimeter Park Drive, Suite 200

Nashville, TN 37211

PUD Name: South Perimeter Park Drive

Case Number: 8-68P-001

Designer: Civil Site Design Group, PLLC2305 Kline Avenue, Suite 300Nashville, TN 37211Phone: (615) 248-9999Contact: Joe Haddix

[email protected]

U.S. FEMA FIRM: 47037C0379H (dated April 05, 2017)

C0.01

C1.00

C2.00

C3.00

L1.0

L2.0

Purpose Note:

The purpose of this plan is to revise thecurrent Planned Unit Development(P.U.D.) to include Parcel 13414000700,±0.91 acres to allow for an expansion tothe existing parking lot.

DATE

COMMENTS

REV.

CHKD

BY:

DRWN

BY:

JMHJRP11/28/2018

INITIAL SUBMITTAL

JMHJRP02/20/2019

RESUBMITTAL

SITE

PARCEL ID: 13414000700

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 24

OWNER/DEVELOPER

3LS PROPERTIES, LLC

301 S. PERIMETER PARK DRIVE STE. 200

NASHVILLE, TN 37211

PHONE NUMBER: (615) 823-5860

CONTACT: BILL TILLERY

E-MAIL: [email protected]

ENGINEER

CIVIL SITE DESIGN GROUP, P.L.L.C.

2305 KLINE AVENUE, STE. 300

NASHVILLE, TN 37211

PHONE NUMBER: (615) 248-9999

CONTACT: JOE HADDIX, P.E.

E-MAIL: [email protected]

COUNCIL DISTRICT 28 - TANAKA VERCHER

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

Page 2: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

FFE:513.2'

FFE:513.4'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

SA

DUMPSTER PAD

TEL

20.0

'

20' SANITARY SEWER EASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10.0'

2 STORYBUILDING

SA

STAIRS 113.9'

94.0'

30.0'

99.9'

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

119.9'

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

(13414000700)

68

13

(13400022600)

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

N01

°23'

24"W

23.7

2'

S89°11'35"E 380.57'

S25°57'03"E

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEW

ALK

I24 RAMPS

PERI

MET

ER P

ARK

DR

JOHNAKIN DR

PERIMETER HILL DR

PARAGON MILLS RD

METROPLEX DR

ANTIOCH PIKE

HARDING PL

HARDING PL

LUNA DR

METROPLEX DR

EISENHOWER DR

Comm. PUD

PUD

OR20

CS

R10

23

4

5

6

78

9

1

20

19

18

17

16

15

14

13

1211

10

21

INTERSTATE 24

FFE:513.2'

FFE:513.4'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

SA

DUMPSTER PAD

TEL

20.0

'

20' SANITARY SEWER EASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10.0'

2 STORYBUILDING

SA

STAIRS 113.9'

94.0'

30.0'

99.9'

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

119.9'

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

(13414000700)

68

13

(13400022600)

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

N01

°23'

24"W

23.7

2'

S89°11'35"E 380.57'

S25°57'03"E

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEW

ALK

ANTIOCH PIKE

ANTIOCH PIKE

I24 RAMP I24 RAMP

S PE

RIM

ETER

PAR

K DR

JOHNAKIN DR

WALLACE RD

JOSAM DR

PERIMETER HILL DR

CANDY LN

PARAGON MILLS RD

METROPLEX DR

ANTIOCH PIKE

HARDING PL

HARDING PL

HARDING PLLUNA DR

METROPLEX DR

EISENHOWER DR

Comm. PUD

PUD

OR20

CS

R10

23

4

5

6

78

9

1

20

19

18

17

16

15

14

13

1211

10

21

INTERSTATE 24

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

20,

201

9 - 8

:22a

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\C

ivil\

PUD

Pla

n\18

-109

-01_

C0.

01_P

UD

Bou

ndar

y Pl

an.d

wg

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

VICINITY MAP

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

SITE

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 2402/20/2019

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

H

T

R

O

N

P.U

.D

. BO

UN

DARY PLAN

C0.01

0 150120906030 300 450

GRAPHIC SCALE 1"=150'

EXISTING PUD BOUNDARY PROPOSED PUD BOUNDARY

PROPOSED ADDITION

TO P.U.D.

PARCEL 13414000700

Page 3: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

WM

20' MBSL

FFE:513.2'

FFE:513.4'

FFE:535.9'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUDE

20' MBSL

20.0'

10' P

UD

E

10' PUDE

20' MINIMUM BUILDINGSETBACK LINEPB.5200, PG.278, R.O.D.C,TN

550

550

548

548

546546

544

542

540

538

538

536

536

534

532

530

530

528

528

526

526

526

524

524

524

524

522

522

522

520

520

520

518

518

516

516

514

514

514

512

510

510

508

508

506

506

504

50450

2

502

SA

SA

SA

SA

SA

SA

SA SA SA

IN:515.9'IN:515.4'IN:515.3'OUT:515.2'

IN:502.4'OUT:502.3'OUT:497.9'

TC:511.4'IN:503.3'OUT:503.1'

TC:519.4'IN:513.1'OUT:511.5'

TC:513.0'IN:507.3'OUT:507.2'

IN:506.3'OUT:506.1'

TC:511.9'WIRED SHUT

BENCHMARKTAG BOLT ONFIRE HYDRANTELEV:527.80'

CANOPY OVER3 MAILBOXES

WM

DUMPSTER PAD

24"RCP

EI:506.6'

WEIR BOXIN:521.0'OUT:521.3'

24"RCPEI:502.3'

TC:516.3'IN:509.2'OUT:509.3'

TC:511.4'WIRED SHUT

TC:512.9'OUT:509.2'

TC:511.8'WIRED SHUT

TC:514.1'IN:508.6'OUT:508.4'

TC:511.5'WIRED SHUT

TC:515.1'IN:508.1'OUT:508.0'

TC:511.7'IN:508.0'OUT:507.9'

TC:511.3'WIRED SHUT

TEL

AT&T BOX

24" RCP

9 SPACES

27 SPACES

11 SPACES11 SPACES24" RCP20

.0'

PB.5200, PG.278, R.O.D.C, TN

38 SPACES

39 SPACES

7 SPACES

10' PUDE

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

8 SPACES

10.0'

10 SPACES

EI:513.4'

EI:513.0'

15 SPACES

13 SPACES

TRANSFORMER

EI:530.1'

EI:518.4'

24" R

CP

7 SPACES 2SPACES

18 SPACES

12" RCP

12" RCP

2 STORYBUILDING

FIRE PIT

EI:515.8'EI:516.3'

12" RC

P

12" R

CP

12" RCP

CONCRETEPLANTERS

SA

SA

SA

SA

SA

SA SA SA

STAIRS 113.9'

94.0'

30.0'

99.9'

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

119.9'

IR(S)

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

BUILDING AREA:1,010 SQ.FT. OR 0.02

ACRES ±

I STORYHOUSE

(13414000700)

68

13

(13400022600)

GRAVEL

IR(S)

SPOT ELEV:524.9'

SPOT ELEV:513.3'

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

N01

°23'

24"W

23.7

2'

S89°11'35"E 380.57'

S25°57'03"E

SPOT ELEV:525.6'513.3'519.8'

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEW

ALK

GRASS

ASPHALT

ASPHALT512

MON.(O)

IR(O)

IR(O)MON.(O)

IR(O)

IR(O)

7 SPACES

LUNA DR

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

20,

201

9 - 8

:22a

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\C

ivil\

PUD

Pla

n\18

-109

-01_

C1.

00 -

Exis

ting

Con

ditio

ns.d

wg

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

VICINITY MAP

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

SITE

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 2402/20/2019

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

0 302010 60 90

GRAPHIC SCALE 1"=30'

H

T

R

O

N

C1.00

EXISTIN

G CO

ND

ITIO

NS

Davidson County, Tennessee (TN037)Map Unit Symbol

TuC

Totals for Area of Interest

Map Unit NameTalbott-Urban Land complex,3 to 12 percent slopes

Acres in AOI

0.91

Percent of AOI

0.91

100%

100%

Page 4: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

WM

20' MBSL

FFE:513.2'

FFE:513.4'

FFE:535.9'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUDE

20' MBSL

20.0'

10' P

UD

E

10' PUDE

20' MINIMUM BUILDINGSETBACK LINEPB.5200, PG.278, R.O.D.C,TN

SA

SA

SA

SA

SA

SA

SA SA SA

IN:515.9'IN:515.4'IN:515.3'OUT:515.2'

IN:502.4'OUT:502.3'

IN:498.1'OUT:497.9'

TC:511.4'IN:503.3'OUT:503.1'

TC:519.4'IN:513.1'OUT:511.5'

TC:513.0'IN:507.3'OUT:507.2'

IN:506.3'OUT:506.1'

TC:511.9'WIRED SHUT

BENCHMARKTAG BOLT ONFIRE HYDRANTELEV:527.80'

CANOPY OVER3 MAILBOXES

WM

DUMPSTER PAD

24"RCP

EI:506.6'

WEIR BOXIN:521.0'OUT:521.3'

24"RCPEI:502.3'

TC:516.3'IN:509.2'OUT:509.3'

TC:511.4'WIRED SHUT

TC:512.9'OUT:509.2'

TC:511.8'WIRED SHUT

TC:514.1'IN:508.6'OUT:508.4'

TC:511.5'WIRED SHUT

TC:515.1'IN:508.1'OUT:508.0'

TC:511.7'IN:508.0'OUT:507.9'

TC:511.3'WIRED SHUT

TEL

AT&T BOX

24" RCP

9 SPACES

27 SPACES

11 SPACES11 SPACES24" RCP20

.0'

PB.5200, PG.278, R.O.D.C, TN

38 SPACES

39 SPACES

7 SPACES

10' PUDE

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

8 SPACES

10.0'

10 SPACES

EI:513.4'

EI:513.0'

15 SPACES

13 SPACES

TRANSFORMER

EI:530.1'

EI:518.4'

24" R

CP

7 SPACES 2SPACES

18 SPACES

12" RCP

12" RCP

2 STORYBUILDING

FIRE PIT

EI:515.8'EI:516.3'

12" RC

P

12" R

CP

12" RCP

CONCRETEPLANTERS

SA

SA

SA

SA

SA

SA SA SA

STAIRS 113.9'

94.0'

30.0'

99.9'

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

119.9'

IR(S)

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

BUILDING AREA:1,010 SQ.FT. OR 0.02

ACRES ±

I STORYHOUSE

(13414000700)

68

13

(13400022600)

GRAVEL

IR(S)

SPOT ELEV:524.9'

SPOT ELEV:513.3'

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

N01

°23'

24"W

23.7

2'

S89°11'35"E 380.57'

S25°57'03"E

SPOT ELEV:525.6'513.3'519.8'

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEW

ALK

GRASS

ASPHALT

ASPHALT

MON.(O)

IR(O)

IR(O)MON.(O)

IR(O)

IR(O)

7 SPACES

LUNA DR

29.2

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

20,

201

9 - 8

:23a

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\C

ivil\

PUD

Pla

n\18

-109

-01_

C2.

00 -

Site

Lay

out a

nd U

tility

Pla

n.dw

g

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

VICINITY MAP

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

SITE

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 2402/20/2019

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

0 302010 60 90

GRAPHIC SCALE 1"=30'

H

T

R

O

N

C2.00

SITE LAYO

UT AN

D U

TILITY PLAN

General Notes:1. All dumpsters, if utilized for this development, shall be located within designated

dumpster enclosures, constructed of wood, masonry or other permanent materialwith walls a minimum of 6 feet in height and opaque gates.

2. Any required handicap parking to be constructed in accordance with ADAstandards and Metro Public Works Department design criteria.

3. Building setbacks shall be per Metro Zoning Code.

4. The final site plan/ building permit site plan shall depict the required publicsidewalks, any required grass strip or frontage zone and the location of allexisting and proposed vertical obstructions within the required sidewalk andgrass strip or frontage zone. Prior to the issuance of use and occupancy permits,existing vertical obstructions shall be relocated outside of the required sidewalk.Vertical obstructions are only permitted within the required grass strip or frontagezone.

Preliminary P.U.D. Plan Notes:Purpose and Intent:The purpose of this plan is to revise the current Planned Unit Development (P.U.D.) toinclude Parcel 13414000700, ±0.91 acres to allow for an expansion to the existingparking lot.

Existing Conditions:The property is currently occupied with 1 single family home.

Development Standards:1. The required fire flow shall be determined by the Metro/Nashville fire marshal's

office prior to the issuance of a building permit.

2. Approval of any PUD plan does not exempt any parcel shown on the plan or anydevelopment within the PUD from compliance with all provisions of the MetroZoning Code with respect to floodplain, steep slopes, unstable soils, sinkholes,rock outcroppings, streams, springs and critical lots.

3. Any excavation, fill or disturbance of the existing ground must be done inaccordance with stormwater management ordinance 78-840 and approved by theMetro Department of Water Services.

4. Individual water and sewer service lines are required for each lot (whereapplicable).

5. The developer of this project shall comply with the requirements of the adoptedtree ordinance 2008-328 (Metro Code Chapter 17.24)

6. If required, a subdivision plat will be submitted with the Final PUD documents.

7. All surface parking areas must meet the "parking area screening andlandscaping" requirements specified in the Metro Zoning Code.

8. According to FEMA's current flood maps, as well as Metro's GIS information,there is no 100-year floodplain within the PUD Amendment Area.

9. According to the NRCS Soils Map, the soils on the property areTuC (Talbott-Urban Land complex, 3 to 12 percent slopes). These soils arenot “problem soils” as noted in section 17.28.050 of the Metro Zoning Code.

10. All access drives and driveways within the community shall be private.

11. There are no known existing wetlands within the PUD Amendment Area.

12. Signage shall meet Metro design standards for the OG zoning district.

13. All development within the boundaries of this plan will be designed based on therequirements of the Americans with Disabilities Act and the Fair Housing Act.

14. The requirements of the Metro Fire Marshal's Office for emergency vehicleaccess and adequate water supply for fire protection must be met prior to theissuance of any building permits.

15. All proposed public utilities and services shall be installed underground.

16. Metro Water Services shall be provided sufficient and unencumbered access inorder to maintain and repair utilities in this site.

17. Size driveway culverts per the design criteria set forth by the Metro StormwaterManagement Manual (minimum driveway culvert in Metro ROW is 15" CMP).

18. Trash and recycling service is to be contracted between the developer / ownerand a private hauler.

19. Landscape:The development of this project shall comply with the requirements of metrozoning code 17.24 tree protection and replacement and with chapter 17.40,article X. Tree protection and replacement procedures. Landscape ordinanceplan to be submitted with the final PUD submittal.

EXTRUDEDCURB(TYP.)

(TYP)

NOTE: Existing utilities toremain. No new utilities arebeing proposed with this plan.

R15

'R

5'

R25'

R15'

R5'

R5'

R5'

R30'

24'

18'

18'

24'

18' 9'

(TYP)

20

19

6

9

8

14

RETAINING WALLw/ PEDESTRIANGUARDRAIL(TYP.)

PROVIDE SMOOTHTRANSITION TOEXISTING

PROVIDE SMOOTHTRANSITION TOEXISTING

LIGHT DUTYPAVEMENT(TYP.)

4" WHITE PAINTEDPARKING STRIPE(TYP.)

PAVEMENTOVERLAY(TYP.)

10

10

Page 5: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

WM

20' MBSL

FFE:513.2'

FFE:513.4'

FFE:535.9'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUDE

20' MBSL

20.0'

10' P

UD

E

10' PUDE

20' MINIMUM BUILDINGSETBACK LINEPB.5200, PG.278, R.O.D.C,TN

550

550

548

548

546546

544

542

540

538

538

536

536

534

532

530

530

528

528

526

526

526

524

524

524

524

522

522

522

520

520

520

518

518

516

516

514

514

514

512

510

510

508

508

506

506

504

50450

2

502

SA

SA

SA

SA

SA

SA

SA SA SA

IN:515.9'IN:515.4'IN:515.3'OUT:515.2'

IN:502.4'OUT:502.3'OUT:497.9'

TC:511.4'IN:503.3'OUT:503.1'

TC:519.4'IN:513.1'OUT:511.5'

TC:513.0'IN:507.3'OUT:507.2'

IN:506.3'OUT:506.1'

TC:511.9'WIRED SHUT

BENCHMARKTAG BOLT ONFIRE HYDRANTELEV:527.80'

CANOPY OVER3 MAILBOXES

WM

DUMPSTER PAD

24"RCP

EI:506.6'

WEIR BOXIN:521.0'OUT:521.3'

24"RCPEI:502.3'

TC:516.3'IN:509.2'OUT:509.3'

TC:511.4'WIRED SHUT

TC:512.9'OUT:509.2'

TC:511.8'WIRED SHUT

TC:514.1'IN:508.6'OUT:508.4'

TC:511.5'WIRED SHUT

TC:515.1'IN:508.1'OUT:508.0'

TC:511.7'IN:508.0'OUT:507.9'

TC:511.3'WIRED SHUT

TEL

AT&T BOX

24" RCP

9 SPACES

27 SPACES

11 SPACES11 SPACES24" RCP20

.0'

PB.5200, PG.278, R.O.D.C, TN

38 SPACES

39 SPACES

7 SPACES

10' PUDE

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

8 SPACES

10.0'

10 SPACES

EI:513.4'

EI:513.0'

15 SPACES

13 SPACES

TRANSFORMER

EI:530.1'

EI:518.4'

24" R

CP

7 SPACES 2SPACES

18 SPACES

12" RCP

12" RCP

2 STORYBUILDING

FIRE PIT

EI:515.8'EI:516.3'

12" RC

P

12" R

CP

12" RCP

CONCRETEPLANTERS

SA

SA

SA

SA

SA

SA SA SA

STAIRS 113.9'

94.0'

30.0'

99.9'

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

119.9'

IR(S)

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

BUILDING AREA:1,010 SQ.FT. OR 0.02

ACRES ±

I STORYHOUSE

(13414000700)

68

13

(13400022600)

GRAVEL

IR(S)

SPOT ELEV:524.9'

SPOT ELEV:513.3'

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

N01

°23'

24"W

23.7

2'

S89°11'35"E 380.57'

S25°57'03"E

SPOT ELEV:525.6'513.3'519.8'

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEWALK

SIDEW

ALK

GRASS

ASPHALT

ASPHALT512

MON.(O)

IR(O)

IR(O)MON.(O)

IR(O)

IR(O)

7 SPACES

LUNA DR

29.2

518

520

522

524

526

528

528

526

524

524

522

520518

518

516

516

518

520

520

522

524

526

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

20,

201

9 - 8

:23a

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\C

ivil\

PUD

Pla

n\18

-109

-01_

C3.

00 -

Gra

ding

& D

rain

age.

dwg

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

VICINITY MAP

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

SITE

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 2402/20/2019

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

0 302010 60 90

GRAPHIC SCALE 1"=30'

H

T

R

O

N

C3.00

GRAD

IN

G AN

D D

RAIN

AG

E PLAN

RETAINING WALLw/ PEDESTRIANGUARDRAIL (TYP)

BIORETENTION AREA (TYP)

NOTE: Water Quality toAchieve 80% TSS Removal

Page 6: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

FFE:513.2'

FFE:513.4'

FFE:535.9'

10' PUBLIC UTILITY & DRAINAGEEASEMENTPB.5200, PG.278, R.O.D.C, TN

10' PUDE

20' MBSL

10' P

UD

E

10' PUDE

550

550

548

548

546546

544

542

540

538

538

536

536

534

530

52852

6524

524

524

522

522

522

520518

516

514

514

SA

SA

TC:511.4'IN:503.3'OUT:503.1'

TC:519.4'IN:513.1'OUT:511.5'

TC:513.0'IN:507.3'OUT:507.2'

WM

DUMPSTER PAD

24"RCP

WEIR BOXIN:521.0'OUT:521.3'

TC:514.1'IN:508.6'OUT:508.4'

TC:511.5'WIRED SHUT

TC:515.1'IN:508.1'OUT:508.0'

TC:511.7'IN:508.0'OUT:507.9'

TC:511.3'WIRED SHUT

39 SPACES10 SPACES

EI:513.4'

EI:513.0'

15 SPACES

13 SPACES

EI:530.1'

FIRE PIT

12" R

CP

12" RCP

CONCRETEPLANTERS

SA

SA

SA

SA

SA

SA

SA

30.1'

99.9'

114.0'

73.9'

30.0'

99.9'

30.1'

IR(S)

LUNA DRIVE

BUILDING AREA:32,884 SQ.FT. OR

0.75 ACRES ±

BUILDING AREA:1,010 SQ.FT. OR 0.02

ACRES ±

I STORYHOUSE

(13414000700)

68GRAVEL

IR(S)

S26°04'10"E 152.19'

S65°04'32"W 295.23'

N26°07'12"W

34.80'

N05

°21'

00"E

136

.01'

N65°05'55"E 224.35'

N26°07'12"W 701.09'

S25°57'03"E

SPOT ELEV:525.6'513.3'519.8'

LOT AREA:40,951 SQ.FT. OR

0.94 ACRES ±

S06°

00'2

9"W

47.2

4'

SIDEWALK

SIDEWALK

SIDEW

ALK

ASPHALT512

MON.(O)

IR(O)MON.(O)

IR(O)

IR(O)

LUNA DR29.2

518

520

522

524

526

528

528

526

524

524

522

520518

518

516

516

518

520

520

522

524

526

TPTP

TP

TP

TP

TP

TP

TPTP

TREES CODE QTY BOTANICAL NAME / COMMON NAME CONT CAL SIZE

ACE GLO 9 ACER RUBRUM `OCTOBER GLORY` TM / OCTOBER GLORY MAPLE B & B 2"CAL 10` - 12` H

ULM BOS 4 ULMUS PARVIFOLIA `BOSQUE` / BOSQUE ELM B & B 2"CAL 10` - 12` H

EVERGREEN TREES CODE QTY BOTANICAL NAME / COMMON NAME CONT CAL SIZE

ILE AME 9 ILEX OPACA / AMERICAN HOLLY B & B 2"CAL 6` - 8` H

MAG ALT 9 MAGNOLIA GRANDIFLORA `ALTA` / ALTA MAGNOLIA B & B 2"CAL 6` - 8` H

PIN SYL 9 PINUS SYLVESTRIS / SCOTCH PINE B & B 2"CAL 6` - 8` H

UNDERSTORY TREES CODE QTY BOTANICAL NAME / COMMON NAME CONT CAL SIZE

CHI VIR 6 CHIONANTHUS VIRGINICUS / WHITE FRINGETREE B & B 2"CAL 6` - 8` H

DECIDUOUS SHRUBS CODE QTY BOTANICAL NAME / COMMON NAME CONT SIZE SPACING

HYD WEE 28 HYDRANGEA QUERCIFOLIA `PEE WEE` / OAKLEAF HYDRANGEA 3 GAL 18" H 42" o.c.

VIB DEN 3 VIBURNUM DENTATUM `ARROWWOOD` / ARROWWOOD VIBURNUM 3 GAL 18" - 24" H 72" o.c.

EVERGREEN SHRUBS CODE QTY BOTANICAL NAME / COMMON NAME CONT SIZE SPACING

PRU SCH 16 PRUNUS LAUROCERASUS `SCHIPKAENSIS` / SCHIPKA LAUREL 3 GAL 24" - 30"H 60" o.c.

TAX DEN 4 TAXUS X MEDIA `DENSIFORMIS` / DENSE YEW 3 GAL 18" H 48" o.c.

TAX HIC 36 TAXUS X MEDIA `HICKSII` / HICKS YEW 3 GAL 18" - 24" H 36" o.c.

PLANT SCHEDULE

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

18,

201

9 - 2

:21p

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\L

ands

cape

Arc

hite

ct\P

UD

Pla

n\18

-109

-01_

Land

scap

e O

rdin

ance

Pla

ns.d

wg

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

VICINITY MAP

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

SITE

LARGO DR

HARDING PLACE

HARDING PLACE

LINBAR DR

WALL

ACE RD

LUNA DR

JOH

NAK

IN D

R

S. P

ERIM

ETER

PAR

K DR

PERIMETER HILL DR

METRO

PLEX DR

INTERSTATE 24

INTERSTATE 24

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

H

T

R

O

N

L1.0

LAN

DSCAPE O

RD

IN

AN

CE PLAN

0 2015105 40 60

GRAPHIC SCALE 1"=20'

EXISTING TREE TO REMAIN (TYP),SEE TREE PROTECTION DETAIL 3/L2.0

LANDSCAPE REQUIREMENTS

PARKING AREA SCREENING - 183 LF

1 tree / 50 LF of parking + continuous row of evergreen shrubs @ 2.5' HT. MAX= 1 required trees | 1 proposed trees

1 tree / 25 LF of parking (section 17.24.150)= 5 required trees | 5 proposed trees

LANDSCAPE BUFFERS (MINIMUM 50% EVERGREEN)

TYPE C - 20' WIDE - 296 LF (6 canopy, 3 understory, 24 shrubs/100 LF)=18 required canopy trees | 18 proposed canopy trees (100% evergreen)=9 required understory trees | 9 proposed understory trees (100% evergreen)=71 required shrubs | 71 proposed shrubs (61% evergreen)

EXISTING TREE TO REMAIN (TYP),SEE TREE PROTECTION DETAIL 3/L2.0

20' WIDE TYPE C - 296 LFLANDSCAPE BUFFER

PARKING AREA SCREENING1 TREE / 50 LF OF PARKING = 1 TREES REQUIRED, 1 PROVIDEDCONTINUOUS ROW OF EVERGREEN SHRUBS @ 2.5' HT MAX., PROVIDED

PARKING AREA SCREENING PER SECTION 17.24.1501 TREE / 25 LF OF PARKING = 5 TREES REQUIRED, 5 PROVIDED

NOTE: 1. TREE SIZES SHOWN ARE REQUIRED MINIMUMS.CONTRACTOR TO REFER TO ENHANCED LANDSCAPE PLANS FOR PRICING. 2. PLEASE NOTE THAT OVERALL SCHEDULE INCLUDES ALLPLANTS FROM BIORETENTION PONDS AND BUFFER PLANTINGS. 3. ALL PLANTS TO BE IRRIGATED BY AN AUTOMATIC SYSTEM OR BE WITHIN100 FEET OF A HOSE BIB.

Page 7: SOUTH PERIMETER PARK DRIVE - Nashville · 2019. 5. 24. · preliminary p.u.d. amendment 347 luna drive nashville , davidson county, tn job no.: 18-109-01 south perimeter park drive

DATE

CO

MM

EN

TS

REV.

JOB NO.: 18-109-01

CH

KD

BY:

DRW

N

BY:

Feb

18,

201

9 - 2

:21p

m T

:\CAD

D\2

018\

18-1

09-0

1\C

AD\L

ands

cape

Arc

hite

ct\P

UD

Pla

n\18

-109

-01_

Land

scap

e O

rdin

ance

Pla

ns.d

wg

PRELIM

IN

ARY PU

D AM

EN

DM

EN

T

SO

UTH

PERIM

ETER PARK D

RIVE

347 LU

NA D

RIVE

NASH

VILLE, D

AVID

SO

N CO

UN

TY, TEN

NESSEE

CASE N

O. 8-68-P

PROJECT BENCHMARK:

DESCRIPTION: TAG BOLT ON

FIRE HYDRANT (NAVD88)

NORTHING: 638,071.757

EASTING: 1,762,527.506

ELEVATION: 527.80'

PARCEL ID: 13414000700

JM

HJRP

11/28/2018

IN

ITIAL SU

BM

ITTAL

FOR PLANNING COMMISSION CONSIDERATION - NOT FOR CONSTRUCTION

PUD CASE #8-68P-001

JM

HJRP

02/20/2019

RESU

BM

ITTAL

L2.0

LAN

DSCAPE N

OTES AN

D D

ETAILS

Planting Notes:1. Any series of trees to be placed in a particular arrangement will be field checked for accuracy by the

Landscape Architect. Any plants misarranged will be relocated by the Contractor at no expense to theOwner. Trees shall be placed on-center when possible unless noted otherwise on plans.

2. Soil used in backfilling planting pits shall be topsoil and mixed with 25% peat by volume, except forericaceous plants, very acid or sour soil (soil having a pH less than 6) shall be mixed with sufficient limeto produce a slightly acid reaction (a pH of 6.0 to 6.5). 10-10-10 commercial fertilizer at the rate of 2pound per cubic yard shall be added. Both fertilizer and peat shall be thoroughly mixed by hand orrotary tiller.

3. Soil used in backfilling ericaceous plants shall be topsoil mixed with 50% peat by volume, 5-10-5commercial fertilizer at the rate of 5 pounds per cubic yard shall be added. Both fertilizer and peat shallbe thoroughly mixed by hand or rotary tiller.

4. Upon securing plant material, and before installation, the Contractor shall notify the LandscapeArchitect for a pre-installation inspection in order to verify all plant material meets specifications. Treesof same species shall be matched in growth character and uniformity.

5. Herbicide (Treflan or equivalent) shall be applied to all planting beds prior to planting for noxious weedcontrol at a rate of 2 pounds per 1,000 square feet.

6. Contractor shall submit a 10 ounce sample of the topsoil proposed to a testing laboratory for analysis.Test results, with recommendations for suitability, shall be submitted to the Owner's Representative forapproval.

7. Plants shall be oriented vertically and oriented for best appearance. All non-biodegradable rootcontainers shall be removed and disposed of off site.

8. Tree branches shall be selectively trimmed by 25%, maintaining natural shape. All dead and brokenbranches in trees and shrubs shall also be pruned. Remove tags, twine or other non-biodegradablematerial, and remove from project site.

9. Scarify subsoil in planting beds to a depth of 3 inches. All planting beds shall receive a minimum of 6inches of topsoil.

10. Contractor shall provide smooth, neatly trenched (3 inch deep) bed edges.11. All planting beds to have a minimum of 3 inch deep shredded hardwood bark mulch.12. Dimensions for trunk caliper, heights, and spread specified on the material schedule are a general

guide for the minimum required size of each plant. Quality & size of plants, spread of roots, and size ofballs shall be in accordance with A.N.S.I. Z60 "American Standard for Nursery Stock" (current edition)as published by the American Association of Nurserymen, Inc.

13. The quantities indicated on the material schedule are provided for the benefit of the Contractor, butshould not be assumed to always be correct. In the event of a discrepancy, the planting plan will takeprecedence over the material schedule. The Contractor shall be responsible for his/her own quantitycalculations and the liability pertaining to those quantities and any related contract documents and/orprice quotations.

14. Contractor shall warranty all material for one year after date of final acceptance.

Sodding Notes:1. Areas indicated for sod shall be Kentucky 31 Fescue, minimum age shall be 18 months, with root

development that will support its own weight without tearing when suspended vertically by holding theupper two corners.

2. Contractor shall submit sod certification for grass species and location of sod source. Contractor shallinclude certification that sod is free of disease, nematodes, undesirable insects, and quarantinerestrictions.

3. Sod shall be delivered on pallets. Prior to installation, sod shall be stored at a location that is protectedfrom damaging effects of sun and wind.

4. 6-12-12 commercial type fertilizer, with 50% of the element derived from organic sources, shall beapplied at a rate recommended by the manufacturer. Apply after smooth raking of topsoil and no morethan 48 hours before laying sod. Mix thoroughly in the upper 2 inches of topsoil and lightly water to aidbreakdown.

5. Areas to receive sod shall be lightly moistened immediately prior to laying sod.6. Lay sod tightly with no open joints visible and not overlapping. Stagger end joints a minimum of 12

inches and do not stretch sod pieces.7. On slopes 6 inches per foot and steeper, lay sod perpendicular to slope and secure every row with

wooden pegs at a maximum 2 feet on-center. Drive pegs flush with sod portion of sod.8. Prior to placing sod on slopes of 8 inches per foot and steeper, place jute erosion control mesh over

topsoil. Securely anchor sod in place with pegs sunk firmly into the ground. Contractor shall submit 12"x 12" samples of jute mesh for review to Landscape Architect or Owner's Representative prior toinstallation.

9. Immediately after installation, water sodded areas to a depth of 4 inches.10. After sod and soil have dried, roll sodded areas to ensure a good bond between soil and sod. Roller

shall not exceed 150 pounds.11. Contractor shall be responsible for maintaining (mowing, trimming, watering) the sod until the

installation is inspected and accepted by the Landscape Architect or Owner's Representative.12. The Contractor shall replace sod areas that show deterioration for a period of one year after acceptance

of the installation. Deteriorated material shall be replaced with sod of equal quality originally specifiedat no expense to the Owner.

Seeding Notes:1. All disturbed areas to be seeded with Kentucky 31 Fescue at the rate of 5 pounds per 1,000 square

feet. All seed to be 98% pure with 85% germination and conform to all state requirements for grassseed. The fertilizer shall be 6-12-12 commercial type with 50% of its elements derived from organicsources.

2. Straw mulch shall be placed upon seeded areas. Straw shall be oats or wheat straw, free from weeds,foreign matter detrimental to plant life, and dry. Hay or chopped cornstalks an not acceptable.

3. Contractor shall verify that the prepared soil base is ready to receive work. The topsoil shall becultivated to a depth of 4 inches with a mechanical tiller and subsequently raked until smooth. Foreignmaterials collected during cultivation and raking operations shall be removed from the project site.

4. Fertilizer shall be applied per the manufacturer's recommendations. Limestone may be applied with thefertilizer. Fertilizer shall be applied after smooth raking and prior to roller compaction and it shall bemixed thoroughly in the upper 2 inches of topsoil.

5. Seed shall be applied evenly in two intersecting directions and raked in lightly. The topsoil shall belightly watered prior to applying seed. Do not seed area in excess of that which can be mulched on thesame day.

6. Roll seeded area with roller not exceeding one and one half pounds.7. Immediately following seeding and compacting, apply straw mulch at the rate of one and one half bale

per 1,000 square feet. Immediately after mulching, apply water with a fine spray and saturate theground to a depth of 4 inches.

8. Contractor shall be responsible for watering seeded areas to prevent grass and soil from drying out untilthe installation is inspected and accepted by the Landscape Architect or Owner's Representative.

9. Contractor shall be responsible for reseeding bare spots for a period or one year after acceptance ofinstallation at no expense to the Owner.

General Notes:1. This property is located within Metro Nashville, Davidson County. Contractor shall conform to all

necessary requirements outlined by the standards of the City of Metro - Nashville.2. All work shall be performed by fully qualified Plantsmen. Use good Horticultural practices to keep all

plants and plant material installed in a living, healthy condition up to the date of termination of theContractor's responsibility for care.

3. The Contractor shall be responsible for examining fully both the site and the bid documents.Discrepancies in the documents or the actual site conditions shall be reported to the LandscapeArchitect in writing at the time of bidding or discovery. No account shall be made after contractcompletion for failure to report such condition, or for errors on the part of the Contractor at the time ofbidding.

4. The Contractor is responsible for locating all underground utilities and shall avoid damage to existingutilities during the course of the work.

5. The Contractor is responsible for repairing any damage to utilities, site structures, etc., resulting fromlandscape construction.

6. The Contractor shall be responsible for securing all necessary applicable permits and licenses toperform the work set forth on this plan set and the specifications.

7. The Contractor shall verify all material quantities. In the event of a discrepancy, the quantities shown onthe plan will take precedence.

8. No material shall be planted before finish grading has been completed.9. The plants delivered to the project site shall be planted as soon as site conditions permit. Contractor

shall take care in scheduling plant deliveries and the size of the deliveries so that long periods ofstorage are avoided. Adequately protect plants placed in temporary storage from the sun and wind;water plants so as to maintain their appearance and health. Plants that have not been properlymaintained during temporary storage may be rejected by the Landscape Architect.

10. Should the Contractor encounter unsatisfactory surface or other subsurface drainage conditions, soildepth, latent soils, hard pan, stem of utility lines or other conditions that will jeopardize the health andvigor of the plants, he/she must advise the Owner's Representative in writing of the conditions prior toinstalling the plants. Otherwise, the Contractor warrants that the planting areas are suitable for propergrowth and development of the plant material to be installed and Contractor shall take responsibility forthe cost of any revision.

11. It is the responsibility of the Contractor to verify that each excavated tree or shrub pit will percolate(drain) prior to adding topsoil of planting mix and installing trees or shrubs. The Contractor shall fill thebottom of selected holes with six inches of water. This water should percolate out within a 24-hourperiod. If the soil at a given area does not drain properly, a PVC drain or gravel sump shall be installed,or the planting relocated to an area approved by the Owner's Representative.

12. Prior to installation of plant materials, the width and length of all parking lot landscape island andmedian areas are to be excavated to a depth of 24 inches below the proposed top of pavementelevation. Excavated material is to be removed from the landscape areas and disposed of off site or inan area approved by the Project Engineer. No asphaltic construction trash and/or materials are to beleft in the topsoil and planting mix backfill and/or subgrade of any proposed parking area islands and/orplanting medians and strips. Parking lot islands and medians are to be backfilled with sifted topsoil asper project specifications and to the elevations indicated on the grading plans.

13. All shrub and ground cover beds not in parking lot islands or median strips are to be excavated to adepth of 12 Inches and disposed of off site or in an area approved by the Project Engineer. Trees inthese bed areas shall be installed per the tree planting detail. The bed area is to be backfilled with siftedtopsoil to the elevations indicated on the grading plans as per the specifications.

14. The optimum time for planting is from October 1 to April 1. Scheduling for planting at other times mustbe approved in writing by the Landscape Architect.

15. Existing trees to remain shall be protected from construction damage. Selectively prune dead wood.16. New tree plantings are to not be staked per planting details. Trees that are planted in special

circumstances of windy conditions may be staked once approved by the Landscape Architect.17. All deciduous trees, existing and proposed shall be pruned to provide 4' minimum clear trunk unless

otherwise noted.18. The Contractor shall stake or mark all plant material locations prior to installation. The Contractor shall

have the Landscape Architect or Owner's Representative approve all staking prior to installation.19. All plant material which dies, turns brown, or defoliates (prior to total acceptance of the work) shall be

promptly removed from the site and replaced with material of the same species quantity and size andmeeting all plant list specifications at no expense to the Owner.

20. The Contractor shall grade planting beds, as required, to provide positive drainage and promoteoptimum plant growth.

21. Chemical Weed Control (pre-emergent, i.e. Treflan) shall be applied to all landscape areas prior to anyplant installation.

22. All planting areas shall receive a 3 inch layer of shredded hardwood bark mulch, which is to bewatered-in after installation.

23. All plants shall be vigorous, healthy material, free of pests and disease.24. All plants and trees must meet all requirements specified in the plant list, details, and notes.25. The standards set forth in "American Standard for Nursery Stock" represent general guideline

specifications only and will constitute minimum quality requirements for plant material. All plants mustmeet minimum size noted on the material schedule. Trees shall be No. 1 grade specimen and shrubsshall be heavy well shaped specimens as well.

26. Dimensions for trunk caliper, heights, and spread specified on the material schedule are a generalguide for the minimum required size of each plant. Quality and size of plants, spread of roots and sizeof balls shall be in accordance with A.N.S.I. Z60 "American Standard for Nursery Stock " (currentedition) as published by the American Association of Nurserymen, Inc.

27. All disturbed areas shall be planted with turf as indicated on the material schedule.28. Existing sod shall be removed as necessary to accommodate new plantings.29. Any existing sod areas that are unnecessarily disturbed during the landscape installation shall be

resodded to match existing at no expense to the Owner.30. The Contractor is responsible for completely maintaining the work (including but not limited to: watering,

mulching, spraying, fertilizing, of all planting areas and lawns per project specifications until totalacceptance of the work by the Owner.

31. The Contractor shall completely guarantee all work for a period of one year beginning at the date oftotal acceptance.

32. The Contractor shall provide the Owner with written instructions on the proper care of all specified plantmaterials prior to final payment.

33. The Contractor shall be responsible for the collection, removal, and proper disposal of any and alldebris generated during the installation of this project.

34. ATTENTION OWNER/ INSTALLER: This landscape plan has been designed to meet the minimumrequirements of the City of Nashville zoning ordinance, the approval of the planning commission, andplanning department policy. Relocating, substituting, resizing, reducing or deleting material may causethe site to no longer conform to the requirements; thus problems may arise with releasing theperformance / maintenance bond for landscaping. Deviation from the approved landscape plan shall notbe made without first consulting Civil-Site Design Group and then obtaining approval from either theCity of Nashville planning commission or the planning department.

35. Prior to installing any plant material in the R.O.W., the Contractor shall contact the City of NashvilleUrban Environmental Department (UED) at (615) 862-6488 for a permit to plant in the R.O.W. Anytrees installed in the City of Nashville's R.O.W. must be inspected by the UED and Landscape Architectprior to installation. Any materials not inspected prior to installation are subject to removal at theContractor's expense.

36. Trees of the same species shall have the following characteristics: matched branching height, caliper,height of tree, spread of branches and branching structure, and overall shape.

37. All on-site utility providers shall be contacted to locate all above ground structures. Once located, theseutility structures shall be screened from the public R.O.W. on three sides.

1L2.0 NTS

6"6"

2L2.0

TREE PIT 2X ROOTBALL DIA.

TREE PLANTING DETAILSECTION NTS

NOTES:

1. DO NOT STAKE TREES UNLESS APPROVED BY THE LANDSCAPEARCHITECT. IF STAKED, REMOVE STAKE AFTER ONE GROWING SEASON.

2. DO NOT WRAP TREE TRUNKS UNLESS APPROVED BY THE LANDSCAPEARCHITECT. IF WRAPPED, REMOVE WRAP AFTER PLANTING.

3. NON-BIODEGRADABLE BURLAP TO BE REMOVED OR ROLLED UNDERROOT BALL AFTER PLANT IS PLACED IN HOLE.

4. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITSPRIOR TO INSTALLATION.

EXISTING TREE LINE

ORANGE PLASTICCONSTRUCTIONFENCING CONNECTINGSTAKES

STAKES JUSTOUTSIDE OFDRIP LINE 10'APART

TREE PROTECTION DETAILPLAN

3L2.0

SHRUB PLANTING DETAILSECTION NTS

NTS

SHREDDED HARDWOOD MULCH, 3" MIN. (TYP.)

SOIL BERM TO HOLD WATER, 6" (TYP.)

FINISHED GRADE, SEE GRADING PLAN

NOTES:

1. NON-BIODEGRADABLE BURLAP TO BE REMOVED OR ROLLED UNDERROOT BALL AFTER PLANT IS PLACED IN HOLE.

2. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITSPRIOR TO INSTALLATION.

12" MIN. DEPTH OF PLANTING SOILFOR GROUNDCOVER BED

PREPARE PLANTING SOIL AS SPEC'D.WHEN GROUND & SHRUBS ARE USED INMASS, ENTIRE BED TO BE EXCAVATEDTO RECEIVE PLANTING SOIL & PLANTMATERIAL, AS SPEC'D.

SET TOP OF ROOT BALL 2" ABOVEFINISHED GRADE

SHREDDED HARDWOOD BARKMULCH, 3" MIN. (TYP.)

SOIL BERM TO HOLD WATER, 6" (TYP.)

UNDISTURBED SOIL

PREPARE PLANTING SOILAS SPECIFIED