Source Changeover

116
2007 Catalogue Source changeover system Compact, Interpact and Masterpact

description

Schneider Electric Source changeover

Transcript of Source Changeover

Page 1: Source Changeover

2007Catalogue

Source changeover system

Compact, Interpact and Masterpact

Page 2: Source Changeover

PB

1008

39

To ensure a continuous supply of electrical power, certain installations are connected to two sources:b a normal source Nb a replacement source R used to supply the installation when the normal source is unavailable.

A source-changeover system switches the load between these two sources. It can be automated to manage transfers according to external conditions. A source-changeover system includes two or three circuit breakers or switch-disconnectors.

With Interpact INS, Compact NS and Masterpact NT and NW, new installation solutions are available to optimise the size of the switchboard and simplify installation.

Interlocking of two Interpact switch-disconnectors via rotary handles.

PB

1008

40

Complete source-changeover assembly with two Interpact switch-disconnectors.

PB

1009

30-6

8

Interlocking of two Compact NS circuit breakers on a base plate.

PB

1008

42

Interlocking of two Masterpact NT and NW circuit breakers using cables.

Page 3: Source Changeover

1

Source-changeover systems General content 0

Presentation 2

Functionsand characteristics 7

Dimensions 37

Electrical diagrams 59

Catalogue numbersand order forms 95

Page 4: Source Changeover

2

Presentation For maximum continuity of service ... 0

PB

1008

43

Manual source-changeover systemThis is the most simple type. It is controlled manually by an operator and consequently the time required to switch from the normal to the replacement source can vary.A manual source-changeover system is made up of two or three mechanically interlocked manually-operated circuit breakers or switch-disconnectors.

Remote-operated source-changeover systemThis is the most commonly employed system for devices with high ratings (above 400 A). No human intervention is required. Transfer from the normal to the replacement source is controlled electrically.A remote-controlled source-changeover system is made up of two or three circuit breakers or switch-disconnectors linked by an electrical interlocking system that may have different configurations. In addition, a mechanical interlocking system protects against electrical malfunctions or incorrect manual operations.

Automatic source-changeover systemsAn automatic controller may be added to a remote-operated source-changeover system for automatic source control according to programmable operating modes.This solution ensures optimum energy management:b transfer to a replacement source according to external requirementsb management of power sourcesb regulationb emergency source replacement, etc.The automatic controller may be fitted with an option for communication with a supervisor.

PB

1008

44

Commercial and service sector:b operating rooms in hospitalsb safety systems for tall buildingsb computer rooms (banks, insurance companies, etc.)b lighting systems in shopping centres…

PB

1008

45

Industry:b assembly linesb engine rooms on shipsb critical auxiliaries in thermal power stations…

PB

1008

46P

B10

0847

Infrastructures:b port and railway installationsb runway lighting systemsb control systems on military sites…

Page 5: Source Changeover

3

Presentation ... in a wide range of applications 0

PB

1008

39

PB

1008

42Interlocking of two Interpact switch-disconnectors via rotary handles.

PB

1008

40

Interlocking of two Masterpact NT and NW circuit breakers using cables.

PB

1008

49

PB

1008

50

Complete source-changeover assembly with two Interpact switch-disconnectors.

PB

1009

57-6

2

Interlocking of two Compact NS circuit breakers on a base plate.

Interlocking of two Masterpact NT or NW circuit breakers using connecting rods.

Interlocking of three Masterpact NW circuit breakers using cables.

Other source-changeover systems: Telemecanique products

PB

1008

48

PB

1008

51

See LC2-D series.

See LC2-F series.

Page 6: Source Changeover

4

Presentation For maximum continuity of service... 0

Incoming feeders and main LV switchboards

PB

1008

53

DB

1015

43

CurrentsFrom 630 to 6300 A.

Power distribution

PB

1008

52

CurrentsFrom 250 to 3200 A.

Loads

PB

1008

54

CurrentsFrom 40 to 400 A.

Page 7: Source Changeover

5

Presentation ... in a wide range of applications 0

1 normal source 1 replacement source

2 sources with coupler on busbars

2 normal sources1 replacement source

DB

1015

38

DB

1015

39

DB

1015

40

QN QR QS1 QC QS2 QN1 QN2 QR0 0 0 0 0 0 0 0

1 0 1 0 1 1 1 00 1 1 1 0 0 0 1

0 1 1 1 0 0

1 0 0 (1) 0 1 00 0 1 (1)

(1) possible by forcing operation.

Generator or permanent source

DB

1015

41

QN QR Typical applications:b continuous production processesb operating roomsb computer rooms...

0 01 00 1

Generator or permanent source

Generator or permanent source

DB

1015

41

DB

1015

44

QN QR Typical applicationsb large electrical installations (e.g. airports)b refrigeration unitsb special electricity tariffsb pumping stations...

0 0

1 00 1

Page 8: Source Changeover

6

Page 9: Source Changeover

7

Source-changeover systems

Functions and characteristics

Presentation 2

Overview of solutionsManual source-changeover systems Interpact INS and Compact NS 40 A to 630 A 8

Overview of solutionsManual source-changeover systems Compact NS andMasterpact NT/NW 630 A to 6300 A 9

Overview of solutionsRemote-operated source-changeover systems Compact NS100/1600 100 A to 1600 A 10

Overview of solutionsRemote-operated source-changeover systemsMasterpact NT/NW 630 A to 6300 A 11

Manual source-changeover systems 12Possible combinations 12

Remote-operated source-changeover systems 16Mechanical interlocking 16General characteristics 18Mechanical and electrical durability 20

Connection and insulation accessories for Compact NS and INS y 630 A 21Electrical interlocking 22Standard configurations 23

Associated controllers 24Controller selection 24Controller installation 25BA controller 26BA controller - Operating sequences 27

Associated controllers 28UA controller 28UA controller - Operating sequences 29

Operating sequences 32

COM communications option 34

Dimensions 37Electrical diagrams 59Catalogue numbers and order forms 95

Page 10: Source Changeover

8

Functions and characteristics

Overview of solutionsManual source-changeover systems Interpact INS and Compact NS 40 A to 630 A 0

Range Interpact CompactModels INS40 to INS80

NS100 to INS160INS250 to INS630INV250 to INV630

NS100 to NS250NS400 to NS630

Rating (A) 40 to 160 100 to 630 100 to 630Type of device Switch-disconnectors with

extended handlesSwitch-disconnectors N/H/L circuit breakers

NA switch-disconnectors

Manual source-changeover systemsInterlocking via toggles

DB

1017

68

DB

1015

45

2 devices side-by-side 3 devices side-by-side

Interlocking via rotary handles

DB

1017

69

DB

1015

46

DB

1015

47

DB

1015

48

2 devices side-by-side

Interlocking via keylocks with captive keys

DB

1017

70

DB

1015

49

DB

1015

50

A number of different devices

Interlocking on a base plate

DB

1017

71

DB

1015

51

2 devices side-by-side

Complete source-changeover assemblies

DB

1017

72

DB

1015

52

2 devices side-by-side

N

2.4

ONI

OOFF

ONI

OOFF

Page 11: Source Changeover

9

Functions and characteristics

Overview of solutionsManual source-changeover systems Compact NS andMasterpact NT/NW 630 A to 6300 A 0

Range Compact MasterpactModels NS630b to NS1600 NT06 to NT16 NW08 to NW63Rating (A) 630 to 1600 630 to 1600 800 to 6300

Type of device N/H/L circuit breakersNA switch-disconnectors

H1/L1 circuit breakersHA switch-disconnectors

N1/H1/H2/H3/L1 circuit breakersNA/HA/HF switch-disconnectors

Manual source-changeover systemsInterlocking via extended rotary handles

DB

1017

69

DB

1015

53

2 devices side-by-side

Interlocking via keylocks with captive keys

DB

1017

70

DB

1015

54

DB

1015

55

DB

1015

56

A number of different devices

Mechanical interlocking using connecting rods

DB

1017

73

DB

1015

57

DB

1015

58

DB

1015

59

2 devices one above the other

(1)

Mechanical interlocking using cables

DB

1017

74

DB

1015

60

DB

1015

61

DB

1015

62

2 or 3 devices one above the other

DB

1017

75

(1)

(2)2 or 3 devices side-by-side

For this case and other cases, please consult us

DB

1019

16

(1) Implemented with NS630b to NS1600 electrically-operated devices only.(2) For source-changeover systems using cables, always respect the installation conditions specified on page 19.

Opush OFF

Ipush ON

O OFF

discharged

Opush OFF

Ipush ON

O OFF

discharged

OpushOFF

IpushON

OOFF

discharged

OpushOFF

IpushON

OOFF

discharged

Page 12: Source Changeover

10

Functions and characteristics

Overview of solutionsRemote-operated source-changeover systems Compact NS100/1600 100 A to 1600 A 0

Range CompactModels NS100 to NS630 NS630b to NS1600Rating (A) 100 to 630 630 to 1600

Type of device N/H/L circuit breakersNA switch-disconnectors

N/H/L circuit breakersNA switch-disconnectors

Remote-operated source-changeover systemMechanical interlocking on base plate + electrical interlocking

DB

1017

71

DB

1015

63

2 electrically-operated devices side-by-side combined with an electrical interlocking system

Mechanical interlocking using connecting rods + electrical interlocking

DB

1017

73

DB

1015

57

2 electrically-operated devices one above the other combined with an electrical interlocking system

Mechanical interlocking using cables + electrical interlocking

DB

1017

77

DB

1015

60

2 electrically-operated devices one above the other combined with an electrical interlocking system

DB

1017

76

2 electrically-operated devices side-by-side combined with an electrical interlocking system

(2)

Automatic source-changeover systemsRemote-operated source-changeover system combined with an automatic-control system

DB

1017

77

The automatic controller operates the devices depending on external parameters.

BA: Simple controller that manages the changeover function.

UA: Controller that also manages engine generator sets.

UA150: UA controller with a communication option.

DB

1015

64

BA controller

DB

1017

76

DB

1015

65

UA and UA150 controller

(2) For source-changeover systems using cables, always respect the installation conditions specified on page 19.

OpushOFF

IpushON

OOFF

discharged

OpushOFF

IpushON

OOFF

discharged

Page 13: Source Changeover

11

Functions and characteristics

Overview of solutionsRemote-operated source-changeover systemsMasterpact NT/NW 630 A to 6300 A 0

Range MasterpactModels NT06 to NT16 NW08 to NW63Rating (A) 630 to 1600 800 to 6300

Type of device H1/L1 circuit breakersHA switch-disconnectors

N1/H1/H2/H3/L1 circuit breakersNA/HA/HF switch-disconnectors

Remote-operated source-changeover systemMechanical interlocking using connecting rods + electrical interlocking

DB

1017

73

DB

1015

58

DB

1015

59

2 electrically-operated devices side-by-side combined with an electrical interlocking system

Mechanical interlocking using cables + electrical interlocking

DB

1017

74

DB

1015

61

DB

1015

62

2 or 3 electrically-operated devices one above the other combined with an electrical interlocking system (1)

DB

1017

75

2 or 3 electrically-operated devices side-by-side combined with an electrical interlocking system (1)

(2)

Automatic source-changeover systemsRemote-operated source-changeover system combined with an automatic-control system

DB

1017

77

The automatic controller operates the devices depending on external parameters.

BA: Simple controller that manages the changeover function.

UA: Controller that also manages engine generator sets.

UA150: UA controller with a communication option.

DB

1015

64

BA controller

DB

1017

76

DB

1015

65

UA and UA150 controller

(1) Three devices with Masterpact NW only.(2) For source-changeover systems using cables, always respect the installation conditions specified on page 19.For other cases, please consult us.

Page 14: Source Changeover

12

Functions and characteristics

Manual source-changeover systems 0

Possible combinations

A manual source-changeover system can be installed on two or three manually-operated and mechanically interlocked circuit breakers or switch-disconnectors.Interlocks prevent connection to both sources at the same time, even momentarily.

All possibilities for manual source-changeover systems

Type of device Type of interlocking for two devicesComplete assembly

Keylock Direct rotary handle

Extended rotary handle

Interpact switch-disconnectors

INS40 to INS160 b

INS250-100 to INS630 b b b r b r

INV100 to 630 b b r b r r

INS/INV630b to 2500 bLegend:r Possible but visible break function disabled.r 250 A and 630 A ratings can be mixed by using INS320/630 rotary handle interlocking system.

Type of device Type of interlocking for two devicesToggle Keylock Direct rotary

handleExtended rotary handle

On base plate (toggle or direct extended rotary control)

On base plate(motor mechanism)

Compact fixed or withdrawable circuit breakers

NS100 to 250 b b b b p b b b b b b b b b b

NS400 to NS630 b b b b p b b b b b b b b b b

NS100 to 630 b b p b b p b b p b b b p b b b p

NS630b to 1600 with rotary handle

b b p b b b b

Legend:b Fixed devices only.b Fixed or withdrawable devices.b Devices must be either both fixed or both withdrawable.p With NS400/630 rotary handle interlocking system.p Possible with NS400/630 base plate + NS100-250 adaptation kit.p Devices equipped with rotary handles.

Type of device Type of interlocking for either all fixed or all withdrawable devicesKeylock Cable-type,

2 devices side-by-side

Cable-type,3 devices side-by-side

Cable-type,2 devices one above the other

Cable-type,3 devices one above another

Rod-type,3 devices one above another

Compact fixed or withdrawable circuit breakers or swith-disconnectors, with motor mechanism NS630b to 1600 b b b bMasterpact fixed or withdrawable circuit breakers or swith-disconnectors, manual operation or with motor mechanism

NT06 to 16 b b b b

NW08 to 63 b b b b b b

NT06 to NW63 b b b

Page 15: Source Changeover

13

Functions and characteristics

Manual source-changeover systems 0

Possible combinations

All possibilities for manual source-changeover systems

DB

1015

71

Complete source-changeover assembly for two switch-disconnectorsThese assemblies provide an easy way to implement source changeover functions with:b a single 3-position rotary handle that controls the two switch-disconnectors (Normal source ON, OFF, Replacement source ON)b a smaller size, taking up less room in the switchboard.A complete source changeover assembly can be ordered with a single catalogue number.

Complete source-changeover assembly for two Interpact INS switch-disconnectors.

"Normal N" "Replacement" RINS250-100 INS250-160 INS200-200 INS250-250 INS320 INS400 INS500 INS630

INS250-100Ratings 100 A bINS250-160Ratings 160 A bINS200-200Ratings 200 A bINS250-250Ratings 250 A bINS320Ratings 320 A bINS400Ratings 400 A bINS500Ratings 500 A bINS630Ratings 630 A b

Possible combinations of “Normal” and “Replacement” source circuit breakers

DB

1015

66

Interlocking of two or three toggle-controlled devicesTwo devices can be interlocked using this system. Two identical interlocking systems can be used to interlock three devices installed side by side, in which case one device is in the ON position and the two others are in the OFF position. Devices must all have the same configuration, i.e. fixed, plug-in, withdrawable or drawout.The system is locked using one or two padlocks (shackle diameter 5 to 8 mm).Two interlocking system models are available for:b Compact NS100 to 250b Compact NS400 to 630.

"Normal N" "Replacement" RInterlocking of two toggle-controlled devices. NS100 NS160 NS250 NS400 NS630

NS100Ratings 16... 100 A b b b b bNS160Ratings 80...160 A b b b b bNS250Ratings 125...250 A b b b b bNS400Ratings 150... 400 A b b b b bNS630Ratings 630 A b b b b b

Page 16: Source Changeover

14

Functions and characteristics

Manual source-changeover systems 0

Possible combinations

Combination of “Normal” and “Replacement” devices

All Interpact, Compact and Masterpact circuit breakers and switch-disconnectors from 100 to 6300 A with rotary handles or motor mechanisms can be interlocked.

DB

1015

69

Interlocking of a number of devices using keylocks (captive keys)Interlocking is based on two identical keylocks with a single key and a keylock adapter (different for each device). This solution enables interlocking between two devices that are physically distant or that have very different characteristics, for example between a low and a medium-voltage device, or between Compact NS circuit breakers and switch-disconnectors.A system of wall-mounted captive key boxes makes possible a large number of combinations between many devices.

Keylock-type interlocking of two circuit breakers with rotary handles or motor mechanisms.

Possible combinations of “Normal” and “Replacement” source circuit breakers

DB

1015

68

Interlocking of two devices with rotary handlesThe direct or extended rotary handles are padlocked with the devices in the OFF position. The mechanism prevents simultaneous closing of the devices, but allows them to be opened.(1) When mixing NS100/250 and NS400/630 circuit breakers, use the NS400/630 interlocking system.

"Normal N" "Replacement" RCompact NS100/630 (1) NS100 NS160 NS250 NS400 NS630

NS100Ratings 16... 100 A b b b v v

Interlocking of two Compact NS circuit breakers with rotary handles.

NS160Ratings 80...160 A b b b v vNS250Ratings 125...250 A b b b v vNS400Ratings 160... 400 A v v v b bNS630Ratings 630 A v v v b bv 250 A and 630 A ratings can be mixed by using NS400/630 rotary handle interlocking system.

"Normal N" "Replacement" RCompact NS630/1600(1) NS630b NS800 NS1000 NS1200 NS1600

NS630bRatings 250... 630 A b b b b bNS800Ratings 320... 800 A b b b b bNS1000Ratings 400... 1000 A b b b b bNS1200Ratings 480... 1200 A b b b b bNS1600Ratings 640... 1600 A b b b b b

(1) When mixing NS100/250 and NS400/630 circuit breakers, use the NS400/630 interlocking system.

ONI

OOFF

ONI

OOFF

Page 17: Source Changeover

15

Functions and characteristics

Manual source-changeover systems 0

Possible combinations

Possible combinations of “Normal” and “Replacement” source switch-disconnectors

DB

1077

42

Interlocking of two Interpact switch-disconnectors with direct rotary handles.

Interlocking of two devices with rotary handlesThe direct or extended rotary handles are padlocked with the devices in the OFF position. The mechanism prevents simultaneous closing of the devices, but allows them to be opened.

"Normal N" "Replacement" RInterpact INS (1) INS40 INS63 INS80 INS100 INS125 INS160INS40Ratings 40 A b b b b b bINS63Ratings 63 A b b b b b bINS80Ratings 80 A b b b b b bINS100Ratings 100 A b b b b b bINS125Ratings 125 A b b b b b bINS160Ratings 160 A b b b b b b

(1) With extended rotary handles only.(2) Possible with INV, but visible-break function is significantly impaired.

"Normal N" "Replacement" RInterpact INS /INV (2) INS250-100/

INV100INS250-160/INV160

INS250-200/INV200

INS250-250/INV250

INS320/INV320

INS400/INV400

INS500/INV500

INS630/INV630

INS250-100/INV100Ratings 100 A b b b b v v vINS250-160/INV160Ratings 160 A b b b bINS250-200/INV200Ratings 200 A b b b bINS250-250/INV250Ratings 250 A b b b b v vINS320/INV320Ratings 320 A v v b b b bINS400/INV400Ratings 400 A b b b bINS500/INV500Ratings 500 A b b b bINS630/INV630Ratings 630 A v v b b b bv 250 A and 630 A ratings can be mixed by using INS320/630 rotary handle interlocking system.

Possible combinations of Compact “Normal” and “Replacement” source circuit breakers

DB

1015

70

Interlocking of two devices on a base plateA base plate is available for mechanical interlocking of two manually-operated Compact circuit breakers or switch-disconnectors."Normal N" "Replacement" R

NS100 NS160 NS250 NS400 NS630NS100Ratings 16... 100 A b b b b bNS160Ratings 80... 160 A b b b b bNS250Ratings 125... 250 A b b b b bNS400Ratings 150... 400 A b b b b b

Interlocking of two manually-operated Compact NS devices on a base plate.

NS630Ratings 630 A b b b b b

Combination of Masterpact devices

DB

1019

03

Interlocking of a number of devices using keylocks (captive keys)Interlocking uses two identical keylocks with a single key. This solution enables interlocking between two devices that are physically distant or that have significantly different characteristics.

pushto

trip

pushto

trip

Page 18: Source Changeover

16

Functionsand characteristics

Remote-operated source-changeover systems 0

Mechanical interlocking

Electrical interlocking of two or three devices is used to create a remote-operated source-changeover system. A basic mechanical interlocking system enhances the reliability of system operation.

Interlocking of two Compact NS100 to 630 devices using a base plateA base plate designed for two Compact circuit breakers can be installed horizontally or vertically on a mounting rail. Interlocking is carried out on the base plate by a mechanism located behind the breakers. Access to the circuit breaker controls and trip units is conserved. Circuit breakers must be fixed or plug-in versions, with or without earth-leakage protection or measurement modules. The base plate and the circuit breakers are supplied separately.b base plate for Compact NS100 to 250 devicesThis base plate is intended for two Compact NS100 to 250 devices.b base plate for Compact NS400 to 630 devicesThis base plate is intended for two Compact NS400 to 630 devices. It may also be used, without any modifications, to interlock a fixed Compact NS100 to 250 with a Compact NS400 or 630 device.An adapter kit is required for plug-in versions of the Compact NS100 to 250 devices.Compact NS100 to 250 devices, in both fixed and plug-in versions, may be equipped with spreaders.

PB

1009

30-6

7

Possible combinations of “Normal” and “Replacement” Compact source circuit breakers

"Normal N" "Replacement" RNS100 NS160 NS250 NS400 NS630

NS100Interlocking of two electrically-operated Compact NS circuit breakers using a base plate.

Ratings 12,5... 100 A b b b b bNS160Ratings 12,5...160 A b b b b bNS250Ratings 12,5...250 A b b b b bNS400Ratings 160... 400 A b b b b bNS630Ratings 250... 630 A b b b b b

DB

1015

72

Interlocking of two Compact NS630b to 1600 or two Masterpact NT and NW devices using connecting rodsThe two devices must be mounted one above the other (either 2 fixed or 2 withdrawable/drawout devices).Combinations are possible between Compact NS630b to NS1600 devices and between Masterpact NT and Masterpact NW devices.

InstallationThis function requires:b an adaptation fixture on the right side of each circuit breaker or switch-disconnectorb a set of connecting rods with no-slip adjustments.The adaptation fixtures, connecting rods and circuit breakers or switch-disconnectors are supplied separately, ready for assembly by the customer.The maximum vertical distance between the fixing planes is 900 mm.

Possible combinations of “Normal” and “Replacement” source circuit breakers

"Normal N" "Replacement" RNS630b to NS1600

NT06 to NT16 NW08 to NW40

NW40b to NW63

NS630b to NS1600Ratings 250... 1600 A b

Interlocking of two Masterpact NT or NW circuit breakers using connecting rods.

NT06 to NT16Ratings 250... 1600 A b b bNW08 to NW40Ratings 320... 4000 A b b bNW40b to NW63Ratings 4000... 6300 A b b b

Page 19: Source Changeover

17

Functions and characteristics

Remote-operated source-changeover systems 0

Mechanical interlocking

PB

1008

42-a

Interlocking of two Compact NS630b to 1600 or two Masterpact NT/NW or up to three Masterpact NW devices using cablesFor cable interlocking, the circuit breakers may be mounted one above the other or side-by-side.The interlocked devices may be fixed or drawout, three-pole or four-pole, and have different ratings and sizes.Interlocking between two devices (Compact NS630b to 1600 or Masterpact NT and NW)This function requires:b an adaptation fixture on the right side of each deviceb a set of cables with no-slip adjustments.The maximum distance between the fixing planes (vertical or horizontal) is 2000 mm.

Interlocking between three devices (Masterpact NW only)This function requires:b a specific adaptation fixture for each type of interlocking, installed on the right side of each deviceb two or three sets of cables with no-slip adjustments.The maximum distance between the fixing planes (vertical or horizontal) is 1000 mm.

InstallationThe adaptation fixtures, sets of cables and circuit breakers or switch-disconnectors are supplied separately, ready for assembly by the customer.

Installation conditions for cable interlocking systems:b cable length: 2.5 mb radius of curvature: 100 mmb maximum number of curves: 3.

Interlocking of two Masterpact circuit breakers using cables.

Possible combinations of “Normal” and “Replacement” source circuit breakers

"Normal N" "Replacement" RNS630b to NS1600

NT06 to NT16 NW08 to NW40

NW40b to NW63

NS630b to NS1600Ratings 250... 1600 A bNT06 to NT16Ratings 250... 1600 A b b bNW08 to NW40Ratings 320... 4000 A b b bNW40b to NW63Ratings 4000... 6300 A b b b

It is not possible to combine Compact NS630b to 1600 and Masterpact NT (or Masterpact NW) devices.All combinations of two Masterpact NT and Masterpact NW devices are possible, whatever the rating or size of the devices.

Possible combinations of three device

NS630b to NS1600

NT06 to NT16 NW08 to NW40

NW40b to NW63

NS630b to NS1600Ratings 250... 1600 ANT06 to NT16Ratings 250... 1600 A

NW08 to NW40Ratings 320... 4000 A b bNW40b to NW63Ratings 4000... 6300 A b b

Only Masterpact NW may be used for three-device combinations.

Types of mechanical interlocking and combinationsSee page 10 to page 15.

Page 20: Source Changeover

18

Functions and characteristics

Remote-operated source-changeover systems 0

General characteristics

Range Compact Types of devices NS100 to NS250 NS400 to NS630Types of circuit breakers N / H / L N / H / LSwitch-disconnector version NA NAMixing possibilities all devices all devices

NS100 to NS250 NS100 to NS630N/H/L/NA N/H/L/NA fixed or plug-in fixed or plug-in

Electrical characteristicsRating 15 to 250 A 15 to 630 AInsulating voltage Ui (V AC) 750 750 Positive break indication b bNumber of poles(N and R devices must have the same number of poles)

3, 4

Electrical durability See page 20Operating temperature –25 °C to +70 °C (50 °C for 440 V - 60 Hz)Control characteristics

Control voltage AC 48 to 415 V - 50/60 Hz 440 V - 60 Hz

DC 24-250 VMaximum consumption AC 500 VA 500 VA

DC 500 W 500 WMinimum switching time 800 ms 800 msInterlocking

Mechanical (see page ...)Electrical by diagram (without IVE) b b

with IVE unit b bauxiliary contacts used by circuit breaker 1 OF + 1 SDE 1 OF + 1 SDE

Protection and measurementOverload protection long time b bShort-circuit protection short time b b

instantaneous b bEarth-fault protection bZone selective interlocking (ZSI) bEarth-leakage protection by Vigi module b b

by control unitby add-on Vigirex relay b b

Current measurementsVoltage, frequency, power measurements, etc.Indication and control auxiliaries

Available auxiliary indication contacts OF + SD (+ SDV) 2 OF + SD (+ SDV)Voltage releases MX shunt b b

MN undervoltage b bVoltage presence indicator b bVoltage transformer b bAmmeter module b bInsulation monitoring module b bSource-changeover controller

With permanent replacement source b BA controllerWith standby generator set b UA controllerRemote communication via bus

Device status indications b bDevice remote controlTransmission of settingsIndication and identification of protection status and alarmsTransmission of measurementsInstallation and connection

Fixed front connectedFixed rear connected b (long rear connections) b (long rear connections)Withdrawable, plug-in or drawout b (plug-in on base) b (plug-in on base)Installation and connection accessories

Downstream coupling accessory b bBare-cable connectors b bTerminal extensions b bTerminal shields and inter-phase barriers bLocking by padlock b b

by keylock b bFront panel escutcheons b b

Page 21: Source Changeover

19

Functions and characteristics

Remote-operated source-changeover systems 0

General characteristics

MasterpactNS630b to NS1600 NT06 to 16 NW08 to 63N / H / L N1 / H1 / H2 / H3 / L1 N1 / H1 / H2 / H3 / L1NA NA / HA / HF NA / HA / HFall devices all mixing possibilities all mixing possibilitiesNS630b to 1600 (fixed, drawout or fixed + drawout) (fixed, drawout or fixed + drawout) N/H/L/NA N1/H1/H2/H3/L1/NA/HA/HF N1/H1/H2/H3/L1/NA/HA/HFfixed or plug-in

250 to 1600 A 600 to 1600 A 800 to 6300 A750 1000 1000b b b

3, 4

See page 20–25 °C to +70 °C (50 °C for 440 V - 60 Hz)

48 to 415 V - 50/60 Hz 440 V - 60 Hz24-250 V

180 VA 180 VA 180 VA180 W 180 W 180 W800 ms 800 ms 800 ms

b b bb only with UA or BA only with UA or BA1 OF + 1 CE (+ SDE) 1 OF + 1 CE + 1 PF 1 OF + 1 CE + 1 PF

b b bb b bb b bb b bb b b

b b bb b bb b b

b b

2 OF + SD 2 OF + SD 2 OF + SDb b bb b b

b bb bb bb b

b BA controllerb UA controller

b b b

b b bb b bb b b

b (vertical or horizontal) b (vertical or horizontal) b (vertical or horizontal)b (drawout) b (drawout) b (drawout)

b

bb b bb b bb b b

Page 22: Source Changeover

20

Functions and characteristics

Remote-operated source-changeover systems 0

Mechanical and electrical durability

Interpact INS switch-disconnectorsINS250-100 INS250-160 INS250-200 INS250

Number of poles 3, 4 3, 4 3, 4 3, 4

Conventional thermal current (A) lth At 60 °C 100 160 200 250Rated operational current (A) Ie Electrical AC, 50/60 Hz AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A

440-480 V 100 100 160 160 200 200 250 250

660-690 V 100 100 160 160 200 200 250 250Durability (category A) (ON-CR-OR-CN cycles)

Mechanical 15000 15000 15000 15000Electrical AC, 50/60 Hz AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A440-480 V 1500 1500 1500 1500 1500 1500 1500 1500660-690 V 1500 1500 1500 1500 1500 1500 1500 1500

INS320 INS400 INS500 INS630Number of poles 3, 4 3, 4 3, 4 3, 4Conventional thermal current (A) lth at 60 °C 320 400 500 630

Rated operational current (A) Ie Electrical AC, 50/60 Hz AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A440-480 V 320 320 400 400 500 500 630 630660-690 V 320 320 400 400 500 500 630 630

Durability (category A) (ON-CR-OR-CN cycles)

Mechanical 10000 10000 10000 10000Electrical AC, 50/60 Hz AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A440-480 V 1500 1500 1500 1500 1500 1500 1500 1500

660-690 V 1500 1500 1500 1500 1500 1500 1500 1500

Compact NS100-NS1600NS100-250 NS400-630 NS630b-

NS1600Number of poles 3, 4 3, 4 3, 4Rated current In (A) 100 to 250 400 to 630 630 to 1600Mechanical durability(ON-CR-OR-CN cycles)

10000 8000 8000

Electrical durability at In (ON-CR-OR-CN cycles) for y 440 V and 480 V NEMA (2)

10000 3000 2000

Electrical durability at In (ON-CR-OR-CN cycles) for U = 500 V to 690 V (2)

1500 1500 1500

Masterpact NT06-NT16/NW08-NW63 (1)

NT06-NT10

NT12-NT16

NW08-NW16

NW20 NW25-NW40

NW50-NW63

Number of poles 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4

Rated current In (A) 630 to 1600

1250 to 1600

800 to 1600

2000 2500 to 4000

5000 to 6300

Mechanical durability(ON-CR-OR-CN cycles)

8000 8000 10000 10000 10000 5000

Electrical durability at In (ON-CR-OR-CN cycles) for y 440 V and 480 V NEMA (2)

6000 6000NT16: 3000

10000 8000 5000 1500

Electrical durability at In (ON-CR-OR-CN cycles) for U = 500 V to 690 V (2)

3000 2000NT16: 1000

10000 6000 2500 1500

(1) Mechanical and electrical durability not applicable to Masterpact H3 and L versions.(2) Electrical durability tests carried out with a power factor of 0.8 as per IEC 947-2.

Note: ON: opening of Normal sourceCR: closing of Replacement sourceOR: opening of Replacement sourceCN: closing of Normal source

Page 23: Source Changeover

21

Functions and characteristics

Connection and insulation accessories for Compact NS and INS y 630 A 0

DB

1016

05

Downstream coupling accessoryThis accessory simplifies connection to bars and cables with lugs.It may be used to couple two circuit breakers (Compact NS100 to 630) or switch-disconnectors (Interpact INS/INV100 to 630) of the same size.Pitch between outgoing terminals:b Interpact INS250 and INV100 to 250: 35 mmb Interpact INS/INV320 to 630: 52.5 mmb Compact NS100 to 250: 35 mmb Compact NS400 to 630: 52.5 mm.For Compact NS circuit-breakers, the downstream coupling accessory can be used only with fixed versions.

Connection and insulation accessoriesThe coupling accessory can be fitted with the same connection and insulation accessories as the circuit breakers and switch-disconnectors.

Possible uses Downstream couplingPossible Outgoing pitch

(mm)

Manual source-changeover systemsINS250 (100 to 250 A) with rotary handle b 35NS100/250 with rotary handle b 35NS100/250 on base plate with toggle control b 35

INS400/630 (320 to 630 A) with rotary handle b 52.5NS400/630 with rotary handle b 52.5NS400/630 on base plate with toggle control b 52.5

Complete source-changeover assemblyINS250 (100 to 250 A) b 35

INS400/630 (320 to 630 A) b 52.5

Remote-operated source-changeover systemsNS100/250 b 35NS400/630 b 52.5

Page 24: Source Changeover

22

Functions and characteristics

Remote-operated source-changeover systems 0

Electrical interlocking

Electrical interlocking is used with the mechanical interlocking system. It electrically interlocks the two circuit breakers and implements the time delays required for proper operation of the system.An automatic controller may be added to take into account information from the distribution system.

Electrical interlocking is carried out by an electrical control device.For Compact NS up to 630 A, electrical interlocking is implemented by the IVE unit integrating control circuits and an external terminal block. The integrated control circuits implement the time delays required for correct source transfer.For Compact NS630b to 1600 and Masterpact, this function can be implemented in one of two ways:b using the IVE unitb by an electrician based on the diagrams presented in the “Electrical diagrams” part of this catalogue.

Characteristics of the IVE unitb external connection terminal block:v inputs: circuit breaker control signalsv outputs: status of the SDE contacts on the “Normal” and “Replacement” source circuit breakersb 2 connectors for the two “Normal” and “Replacement” source circuit breakers:v inputs:- status of the OF contacts on each circuit breaker (ON or OFF)- status of the SDE contacts on the “Normal” and “Replacement” source circuit breakersv outputs: power supply for operating mechanismsb control voltage:v 24 to 250 V DCv 48 to 415 V 50/60 Hz - 440 V 60 Hz.The IVE unit control voltage must be same as that of the circuit breaker operating mechanisms.

DB

1015

73

IVE unit.

Necessary equipmentFor Compact NS100 to 630, each circuit breaker must be equipped with:b a motor mechanismb an OF contactb an SDE contact.The components are supplied ready for assembly and the circuit breakers prewired. The prewiring must not be modified.

For Compact NS630b to 1600, each circuit breaker must be equipped with:b a motor mechanismb an available OF contactb a CE connected-position contact (carriage switch) on withdrawable circuit breakersb an SDE contact.

For Masterpact NT and NW, each circuit breaker must be equipped with:b a remote-operation system made up of:v MCH gear motorv MX or MN opening releasev XF closing releasev PF “ready to close” contactb an available OF contactb one to three CE connected-position contacts (carriage switches) on drawout circuit breakers (depending on the installation).

Page 25: Source Changeover

23

Functions and characteristics

Remote-operated source-changeover systems 0

Standard configurations

Compact NS, Masterpact NT and NW Types of mechanical interlocking Possible combinations Typical electrical diagrams Diagram no.2 devices

DB

1015

74

QN QR Compact NS100 to 630:0 0 b electrical interlocking without emergency

power off (EPO) auxiliaries: 512011771 0v with EPO by MN 512011780 1v with EPO by MX 51201179Compact NS630b to 1600:b electrical interlocking with lockout after fault:v permanent replacement source (without IVE) 51201180v with EPO by MX (without IVE) 51201181v with EPO by MN (without IVE) 51201182v permanent replacement source (with IVE) 51201183v with EPO by MX (with IVE) 51201184v with EPO by MN (with IVE) 51201185b automatic control without lockout after fault:

v permanent replacement source (without IVE) 51201186v engine generator set (without IVE) 51201187Masterpact NT and NW:b electrical interlocking with lockout after fault:v permanent replacement source (without IVE) 51201139v with EPO by MX (without IVE) 51201140v with EPO by MN (without IVE) 51201141v permanent replacement source (with IVE) 51201142v with EPO by MX (with IVE) 51201143v with EPO by MN (with IVE) 51201144b automatic control without lockout after fault:

v permanent replacement source (without IVE) 51156226v engine generator set (without IVE) 51156227b automatic control with lockout after fault:

v permanent replacement source (with IVE) 51156904v engine generator set (with IVE) 51156905b BA/UA controller (with IVE) 51156903

Masterpact NW onlyTypes of mechanical interlocking Possible combinations Typical electrical diagrams Diagram no.3 devices: 2 “Normal” sources and 1 “Replacement” source

DB

1015

75

QN1 QN2 QR b electrical interlocking:0 0 0 v without lockout after fault 511569061 1 0 v with lockout after fault 511569070 0 1

3 devices: 2 “Normal” sources and 1 “Replacement” source with source selection

DB

1015

76

QN1 QN2 QR b automatic control with engine generator set:

0 0 0 v without lockout after fault (with MN) 511569081 0 0 v with lockout after fault (with MN) 511569090 0 1

1 1 00 1 0

3 devices: 3 sources, only one device

DB

1015

77

QS1 QS2 QS3 b electrical interlocking:0 0 0 v without lockout after fault 511569101 0 0 v with lockout after fault 511569110 1 00 0 1

3 devices: 2 sources + 1 coupling

DB

1015

78

QS1 QC QS2 b electrical interlocking:

0 0 0 v without lockout after fault 511569121 0 1 v with lockout after fault 511569131 1 0 b automatic control with lockout after fault 511569140 1 11 0 0 (1)

0 0 1 (1)

(1) possible by forcing operation

“Lockout after fault” option. This option makes it necessary to manually reset the device following fault tripping.

Page 26: Source Changeover

24

Functions and characteristics

Associated controllers 0

Controller selection

By combining a remote-operated source-changeover system with an integrated BA or UA automatic controller, it is possible to automatically control source transfer according to user-selected sequences.These controllers can be used on source-changeover systems comprising 2 circuit breakers.For source-changeover systems comprising 3 circuit breakers, the automatic control diagram must be prepared by the installer as a complement to to diagrams provided in the “electrical diagrams” section of this catalogue.

Controller BA UACompatible circuit breakers All Compact NS and

Masterpact circuit breakers

4-position switchAutomatic operation b bForced operation on “Normal” source b bForced operation on “Replacement” source b bStop (both “Normal” and “Replacement” sources off) b bAutomatic operation

Monitoring of the “Normal” source and automatic transfer b bGenerator set startup control bDelayed shutdown (adjustable) of generator set bLoad shedding and reconnection of non-priority circuits bTransfer to the “Replacement” source if one of the phases of the “Normal” phase is absent

b

TestBy opening the P25M circuit breaker supplying the controller b

PB

1008

55

By pressing the test button on the front of the controller bIndications

Circuit breaker status indication on the front of the controller: on, off, fault trip

b b

Automatic mode indicating contact b bOther functions

Selection of type of “Normal” source (single-phase or three-phase) (1)

b

Voluntary transfer to “Replacement” source (e.g. energy management commands)

b b

During peak-tariff periods (energy management commands) forced operation on “Normal” sourceif “Replacement” source not operational

b

Additional contact (not part of controller). Transfer to “Replacement” source only if contact is closed. (e.g. used to test the frequency of UR).

b b

BA controller. Setting of maximum startup time for the replacement source bOptions

PB

1008

56

Communication option

Power supplyControl voltages (2) 110 V b b

220 to 240 V 50/60 Hz b b380 to 415 V 50/60 Hz and 440 V 60 Hz

b b

Operating thresholdsUndervoltage 0.35 Un y voltage y 0.7 Un b bPhase failure 0.5 Un y voltage y 0.7 Un bVoltage presence voltage u 0.85 Un b bIP degree of protection (EN 60529) and IK degree of protection against external mechanical impacts (EN 50102)

Front IP40 b bSide IP30 b bConnectors IP20 b b

UA controller. Front IK07 b bCharacteristics of output contacts (dry, volt-free contacts)

Rated thermal current (A) 8Minimum load 10 mA at 12 VOutput contacts:Position of the Auto/Stop switch b bLoad shedding and reconnection order bGenerator set start order. b

AC DCUtilisation category (IEC 947-5-1) AC12 AC13 AC14 AC15 DC12 DC13Operational current (A) 24 V 8 7 5 5 8 2

48 V 8 7 5 5 2 -110 V 8 6 4 4 0.6 -220/240 V 8 6 4 3 - -250 V - - - - 0.4 -380/415 V 5 - - - - -440 V 4 - - - - -660/690 V - - - - - -

(1) For example, 220 V single-phase or 220 V three-phase.(2) The controller is powered by the ACP auxiliaries control plate. The same voltage must be used for the ACP plate, the IVE unit and the circuit-breaker operating mechanisms. If this voltage is the same as the source voltage, then the “Normal” and “Replacement” sources can be used directly for the power supply. If not, an isolation transformer must be used.

Page 27: Source Changeover

25

Functions and characteristics

Associated controllers 0

Controller installation

PB

1008

57

ACP auxiliaries control plateThe auxiliaries control plate provides in a single unit:b protection for the BA or UA controller with two highly limiting P25M circuit breakers (infinite breaking capacity) for power drawn from the AC sourceb control of circuit-breaker ON and OFF functions via two relay contactorsb connection of the circuit breakers to the BA or UA controller via a built-in terminal block.

Control voltagesb 110 V 50/60 Hzb 220 to 240 V 50/60 Hzb 380 to 415 V 50/60 Hz and 440 V 60 Hz.The same voltage must be used for the ACP plate, the controller and the circuit-breaker operating mechanisms.

InstallationConnection between the ACP auxiliaries control plate and the IVE electrical-interlocking unit may use:b wiring done by the installerb prefabricated wiring (optional).

Installation of the BA and UA controllersThe BA and UA controllers may be installed in one of two manners:b directly mounted on the ACP auxiliaries control plateb mounted on the front panel of the switchboard.The length of the connection between the ACP plate and the controller must not exceed two metres. Wiring is done by the installer.ACP auxiliaries control plate.

DB

1015

79

Mounting on the ACP plate.

DB

1015

80

Mounting on the front panel of the switchboard.

Page 28: Source Changeover

26

Functions and characteristics

Associated controllers 0

BA controller

The BA controller is used to create simple source-changeover systems that switch from one source to another depending on the presence of voltage UN on the “Normal” source.It is generally used to manage two permanent sources and can control Compact NS and Masterpact NT/NW circuit breakers and switch-disconnectors.

Operating modesA four-position switch may be used to select:b automatic operationb forced operation on the “Normal” sourceb forced operation on the “Replacement” sourceb stop (both “Normal” and “Replacement” sources off).

Setting the time delaysTime delays are set on the front of the controller.t1. delay between detection that the “Normal” source has failed and the transmission of the order to open the “Normal” source circuit breaker (adjustable from 0.1 to 30 seconds).t2. delay between detection that the “Normal” source has returned and the transmission of the order to open the “Replacement” source circuit breaker (adjustable from 0.1 to 240 seconds).

Circuit breaker commands and status indicationsThe status of the circuit breakers is indicated on the front of the controller.b ON, OFF, fault.A built-in terminal block may be used to connect the following input/output signals:b inputs:v voluntary order to transfer to source R (e.g. for special tariffs, etc.)v additional control contact (not part of the controller). Transfer to the “Replacement” source takes place only if the contact is closed (e.g. used to test the frequency of UR, etc.)b outputs:indication of operation in automatic or stop mode via changeover contacts.

TestIt is possible to test the operation of the BA controller by turning OFF (opening) the P25M circuit breaker for the “Normal” source and thus simulating a failure of voltage UN.

PB

1008

58D

B10

1779

Front of the BA controller.

Page 29: Source Changeover

27

Functions and characteristics

Associated controllers 0

BA controllerOperating sequences

Switch set to Auto (automatic operation and special-tariff mode) Switch set to the “N” position (forced operation on the “Normal” source)

DB

1015

82

DB

1015

84

Switch set to the “R” position (forced operation on the “Replacement” source)

Switch set to the “Stop” position

DB

1015

86

DB

1015

88

KeyUN : “Normal” source voltageUR : “Replacement” source voltageN : “Normal” source circuit breakerR : “Replacement” source circuit breaker

WAITING The system exits this mode when the operating mode is modified or when an external event occurs (e.g. failure or return of UN).

The number sends to the indicated step when the condition is true.

1

Page 30: Source Changeover

28

Functions and characteristics

Associated controllers 0

UA controller

The UA controller is used to create a source-changeover system integrating the following automatic functions:b transfer from one source to another depending on the presence of voltage UN on the “Normal” sourceb startup of an engine generator setb shedding and reconnection of non-priority circuitsb transfer to the “Replacement” source if one of the phases on the “Normal” source fails.The UA controller can control Compact NS and Masterpact NT/NW devices.

Operating modesA four-position switch may be used to select:b automatic operationb forced operation on the “Normal” sourceb forced operation on the “Replacement” sourceb stop (both “Normal” and “Replacement” sources off, then manual operation).

Setting the time delaysTime delays are set on the front of the controller.t1. delay between detection that the “Normal” source has failed and the transmission of the order to open the “Normal” source circuit breaker (adjustable from 0.1 to 30 seconds).t2. delay between detection that the “Normal” source has returned and the transmission of the order to open the “Replacement” source circuit breaker (adjustable from 0.1 to 240 seconds).t3. delay following opening of QN with load shedding and before closing of QR (adjustable from 0.5 to 30 seconds).t4. delay following opening of QR with load reconnection and before closing of QN (adjustable from 0.5 to 30 seconds).t5. delay for confirmation that UN is present before shutting down the engine generator set (adjustable from 60 to 600 seconds).t6. delay before startup of the engine generator set (120 or 180 seconds).

Commands and indicationsCircuit breaker status indications on the front of the controller:b ON, OFF, fault.A built-in terminal block may be used to connect the following input/output signals:b inputs:v voluntary order to transfer to source R (e.g. for special tariffs, etc.)v additional control contact (not part of the controller). Transfer to the “Replacement” source takes place only if the contact is closed (e.g. used to test the frequency of UR, etc.)b outputs:v control of an engine generator set (ON / OFF)v shedding of non-priority circuitsv indication of operation in automatic mode via changeover contacts.

Distribution-system settingsThree switches are used to:b select the type of “Normal” source, whether single-phase or three-phase (e.g. 240 V single-phase or 240 V three-phase)b select whether to remain (or not) on the “Normal” source if the “Replacement” source is not operational during operation on special tariffsb select the maximum permissible startup time for the engine generator set during operation on special tariffs (120 or 180 seconds).

TestA pushbutton on the front of the controller may be used to test transfer from the “Normal” source to the “Replacement” source, then the return to the “Normal” source. The test lasts approximately three minutes.

COM communications optionUsing the internal bus protocol, this option may be used to remote the following information:b circuit breaker status (ON, OFF, fault trip)b presence of the “Normal” and “Replacement” voltagesb presence of an order for forced operation (e.g. special tariffs)b settings and configuration informationb status of non-priority circuits (loads shed or not)b position of the switch (stop, auto, forced operation on the “Normal” source, forced operation on the “Replacement” source).

PB

1008

58D

B10

1778

Front of the UA controller.

Page 31: Source Changeover

29

Functions and characteristics

Associated controllers 0

UA controllerOperating sequences

Switch set to the “R” position (forced operation on the “Replacement” source) Switch set to the “N” position (forced operation on the “Normal” source)

DB

1015

90

DB

1015

92

Switch set to the “Stop” position

DB

1015

94

WAITING The system exits this mode when the operating mode is modified or when an external event occurs (e.g. failure or return of UN).

When the UA controller is not energised, the output for generator set startup is activated).

KeyUN : “Normal” source voltageUR : “Replacement” source voltageN : “Normal” source circuit breakerR : “Replacement” source circuit breaker

Page 32: Source Changeover

30

Functions and characteristics

Associated controllers 0

UA controllerOperating sequences

Switch set to the “Auto” position (special-tariff mode)

DB

1015

96 WAITING The system exits this mode when the operating mode is modified or when an external event occurs (e.g. failure or return of UN).

When the UA controller is not energised, the output for generator set startup is activated).

KeyUN : “Normal” source voltageUR : “Replacement” source voltageN : “Normal” source circuit breakerR : “Replacement” source circuit breakerB : Penalties accepted (N ON), i.e. B = 1

The number sends to the indicated step when the condition is true.

1

Page 33: Source Changeover

31

Functions and characteristics

Associated controllers 0

UA controllerOperating sequences

Switch set to the “Auto” position (automatic operation and test mode).

DB

1015

98

WAITING The system exits this mode when the operating mode is modified or when an external event occurs (e.g. failure or return of UN).

When the UA controller is not energised, the output for generator set startup is activated).

KeyUN : “Normal” source voltageUR : "Replacement” source voltageN : “Normal” source circuit breakerR : “Replacement” source circuit breaker B : Penalties accepted (N ON), i.e. B = 1(*) The test lasts 180 seconds.

The number sends to the indicated step when the condition is true.

1

Page 34: Source Changeover

32

Functions and characteristics

Operating sequences 0

IVE unit

DB

1016

00

SymbolsQN : “Normal” Compact C circuit breaker equipped

for remote operation (motor mechanism)QR : “Replacement” Compact C circuit breaker

equipped for remote operation (motormechanism)

ON : Circuit breaker QN opening orderOR : Circuit breaker QR opening orderIN : Circuit breaker QN closing orderIR : Circuit breaker QR closing orderL1 : Faulty “Normal” indication LEDL2 : Faulty “Replacement” indication LED

KeyO: OFF (circuit open)I: ON (circuit closed

: either ON or OFF.

Note: Following all trips (overload, short-circuit, earth-leakage fault, voluntary trip), a manual reset on the front of the motor mechanism is required.

Page 35: Source Changeover

33

Functions and characteristics

Operating sequences 0

BA controller

DB

1016

02

InputsUN : “Normal” source voltageUR : “Replacement” source voltageKT : order for forced-operation on RKR : additional check before transfer

OutputsQN : “Normal” source circuit breakerQR : “Replacement” source circuit breaker

UA controller

DB

1016

04

InputsUN : “Normal” source voltageUR : “Replacement” source voltageKT : order for forced-operation on RKR : additional check before transfer

OutputsKG : order to the gensetSH : load-shedding orderQN : “Normal” source circuit breakerQR : “Replacement” source circuit breaker

KeyO: OFF (circuit open)I: ON (circuit closed

: either ON or OFF.

ImportantIf UR is not ON when the transfer order is issued (KT or UN), the sequence is not carried out.If KR status is not ON when the transfer order is issued (KT or UN), the transfer sequence is carried out later when KR status becomes I.

Page 36: Source Changeover

34

Functions and characteristics

COM communications option 0

DB

1019

28

Communications option for Compact NS and Masterpact NT/NWThe COM communications option is compatible with all the source-changeover systems for Compact NS100 to 1600 and Masterpact NT/NW circuit breakers and switch-disconnectors.It can be used to remote status information. It may not be used to operate the circuit breakers (only possible locally on the front of the UA150 controller).Masterpact and Compact NS630b to 1600 circuit breakers and switch-disconnectors are compatible with the Modbus ECO COM option.Depending on the trip units or control units used, the COM option may also be used to analyse distribution-system parameters required for the operating and maintenance assistance.

Circuit breaker communicationSwitch-disconnector

Circuit breaker

Compact NS100/1600 status indicationsON / OFF b bFault trip bConnected / disconnected position b b

Masterpact NT/NW status indicationsON / OFF b bFault trip bConnected / disconnected position b b

Operating and maintenance assistanceSTR53UE trip unit for Compact NS400/630

Current readingsPhase and neutral rms currents bCurrent on the most heavily loaded phase bAlarm readingsOverload bTripping cause (overload, short-circuit, etc.) bPositions of setting dials b

Operating and maintenance aids Digipact ModbusMeasurementCurrent A P H A P HVoltages, frequency, power, etc. P H P H

Power quality: fundamental, harmonics HProgramming of demand metering P HFault readingsType of fault A P HInterrupted current P HWaveform captureOn faults HOn demand or programmed HHistories and logsTrip history P HAlarm history P HEvent logs P H

IndicatorsCounter operation A P H A P HContact wear P H

Maintenance register P HNote: see the description of the Micrologic control units for further details on protection and alarms, measurements, waveform capture, histories, logs and maintenance indicators.

Page 37: Source Changeover

35

Functions and characteristics

COM communications option 0

Automatic source-changeover controllerUA150

Status indications“Normal” sourceON / OFF bCircuit breaker ON bFault trip (SDE) bVoltage presence b“Replacement” sourceCircuit breaker ON bFault trip (SDE) bVoltage presence bStatus of R voltage contact bControllerAutomatic mode b“Normal” mode b“Replacement” mode bStop mode bTesting b“Replacement” engine generator setGenset failure bGenset OFF bGenset ON bShedding of non-priority circuits bReconnection of non-priority circuits b

Settings

Time delay t1 for validation of UN absence b

Time delay t2 for validation of UN return bTime delay t3 for wait between opening of N and closing of R bTime delay t4 for wait between opening of R and closing of N bTime delay t5 for wait between return of UN and order for genset shutdown bTime delay t6 for wait before declaring genset failure bPenalties accepted to avoid special tariff transfer b

Page 38: Source Changeover

36

Page 39: Source Changeover

37

Source-changeover systems

Dimensions

Presentation 2Functions and characteristics 7

Manual source-changeover systems 39Interlocking of direct rotary handles 39Interlocking of extended rotary handles 40Interlocking of toggles 42Complete source-changeover assembly 43Downstream coupling accessory 44

Remote-operated source-changeover systems 46Interlocking on a base plate 46Interlocking using connecting rods 50Interlocking using cables 52IVE electrical-interlocking unitBA and UA automatic controllers 57

Electrical diagrams 59Catalogue numbers and order forms 95

Page 40: Source Changeover

38

Page 41: Source Changeover

39

Dimensions Manual source-changeover systems 0

Interlocking of direct rotary handles

Compact NS100 to 1600Dimensions Front-panel cut-out

DB

1016

06

DB

1016

07

DB

1016

08

Dimensions (mm) Type A B C D F G H J K L M N P

NS100/160/250N/H/L 325 90 87.5 175 156 133 9.25 9 295 75.5 150 75 155NS400/630N/H/L 416 115 100 200 210 157 5 24.6 386 100 175 74.5 179

Interpact INS/INV250 100 to 250 A / Interpact INS/INV320/400/500/630Dimensions Front-panel cut-out

DB

1016

09

DB

1016

10

DB

1016

11

Dimensions (mm) Type A B C D F G H K L M N P

INS/INV250 100/160/250 A 325 90 87.5 175 156 106 17.5 295 75.5 150 75 131INS/INV320/400/500/630 416 115 100 200 210 130 22.5 386 100 175 74.5 160.4Note: X et Y are the symmetry planes for a 3-pole device.

Page 42: Source Changeover

40

Dimensions Manual source-changeover systems 0

Interlocking of extended rotary handles

Compact NS100 to 630Dimensions Front-panel cut-out

DB

1016

12

DB

1016

07

DB

1077

57

Dimensions (mm) Type A B C D F G min G max H J P Q

NS100/160/250N/H/L 325 90 87.5 175 156 185 600 9.25 9 25.5 25.5NS400/630N/H/L 416 115 100 200 210 204 600 5 24.6 30.8 30.8

Interpact INS40/63/80/100/125/160 / Interpact INS/INV250 100 to 250 A / Interpact INS/INV320/400/500/630Dimensions Front-panel cut-out

DB

1016

14

DB

1016

15

DB

1077

56

Dimensions (mm) Type A B C D F G min G max H P Q

INS40/63/80 325 90 87.5 175 156 155 396 0 25.5 25.5INS100/125/160 325 90 87.5 175 156 200 441 0 25.5 25.5INS/INV250 100/160/250 A 325 90 87.5 175 156 185 600 17.5 25.5 25.5

INS320/400/500/630 416 115 100 200 210 204 600 22.5 30.8 30.8

Page 43: Source Changeover

41

Dimensions Manual source-changeover systems 0

Interlocking of extended rotary handles

Compact NS630b to 1600Dimensions

DB

1016

17

DB

1016

18

Front-panel cut-out

DB

1016

19

Dimensions (mm) Type A B C D F G min G max H J P Q R

NS630b/800/1000/1200/1600 411 63.5 98 175 280 218 605 25 24 25.5 25.5 64

Page 44: Source Changeover

42

Dimensions Manual source-changeover systems 0

Interlocking of toggles

Compact NS100 to 630Dimensions 3 poles 4 poles

DB

1016

20

DB

1016

21

DB

1016

22

Front-panel cut-out 3 poles on left 4 poles on left

DB

1016

23

DB

1016

24

Dimensions (mm) Type C2 C3 L L16 L17 L18 R2 R18 R19 P5 P

NS100/160/250N/H/L 54 108 52.5 140 245 280 54 89 140 83 115NS400/630N/H/L 92.5 184 70 185 325 370 71.5 116.5 185 107 144

Page 45: Source Changeover

43

Dimensions Manual source-changeover systems 0

Complete source-changeover assembly

Assembly for INS250 100 to 250 A / Assembly for INS320/400/500/630Dimensions

DB

1016

25

DB

1016

26

Front-panel cut-out

DB

1016

27

Dimensions (mm) Type A B C D E F G H I J K L M N

INS250 60.4 130.4 296 68 136 131 61.8 279.3 42 84 156 186.5 5.5 50INS320/630 82.5 175 395 102.5 205 155 87 383.7 64 128 210 213 8 50

Dimensions of the complete source-changeover assembly with an extended handle

DB

1016

50

DB

1016

51

DB

1077

43

Dimensions (mm) Type A B C E K L M N

INS250INV100/250

60.4 130.4 295 136 156 138.5 631 50

INS320/630INV320/630

82.5 175 395 205 210 162.5 658 75

Dimensions (mm) Type P Mmax Mmin Q

INS250INV100/250

100 567.5 195 64

INS320/630INV320/630

150 593 220.5 64

Note: Lines X and Y indicate the axes of symmetry of the switch-disconnector.Reference plane Z corresponds to the back of the switch-disconnector.

Page 46: Source Changeover

44

Dimensions Manual source-changeover systems 0

Downstream coupling accessory

Compact NS100 to NS630 (only for Compact NS fixed devices)Dimensions

DB

1016

28

DB

1016

29

Dimensions Connection

DB

1016

30

DB

1016

31

Dimensions (mm) Type G2 G3 G28 G29 G30 G52 K1 K2 K3 K4 K8 K9 K16

NS100/160/250 118 181.5 238 96 140 156 35 35 51 156 70 170 8

NS400/630 165.9 265.7 339.5 143.5 188.5 227.5 45 52.5 75 210 113.5 250.7 3.75

Dimensions (mm) Type L28 L29 L30 L31 L32 L33 L34 L35 L36 L37 L39 L40 ØT

NS100/160/250 320 99.5 300 89.5 1 123 139.5 74.5 19.5 87.5 9.5 140 6NS400/630 420 127.5 400 117.5 11.2 187.5 - 96.5 26 115 22.5 210 6

Note: coupling accessory: only for changeover systems using fixed versions of Compact NS circuit breakers.

Page 47: Source Changeover

45

Dimensions Manual source-changeover systems 0

Downstream coupling accessory

Interpact INS250 100 to 250 A / Interpact INS320/400/500/630Dimensions

DB

1016

32

DB

1016

33

Dimensions Connection

DB

1019

01

DB

1019

02

Dimensions (mm) Type G2 G3 G28 G29 G30 G52 K1 K2 K3 K4 K8 K9 K16

INS250-100/160/200/250 105.5 169 225.5 83.5 127.5 143.5 35 35 51 156 57.5 157.5 25.5NS320/400/500/630 141 240.7 315 119 163.5 202.5 45 52.5 75 210 88.5 225.7 26.25

Dimensions (mm) Type L28 L29 L30 L31 L32 L33 L34 L35 L36 L37 L39 L40 ØT

INS250-100/160/200/250 320 82 300 72 16.5 123 139.5 74.5 21.5 70 8.5 140 6NS320/400/500/630 420 105 400 95 11.2 187.5 - 98.5 26 92.5 0 210 6

Page 48: Source Changeover

46

Dimensions Remote-operated source-changeover systems 0

Interlocking on a base plate

Compact NS100 to 250Dimensions, 3 or 4 poles Fixed device Withdrawable device

DB

1016

34

DB

1016

35

DB

1016

36

(*) Short terminal shields are mandatory.

Vertical mounting Horizontal mounting

DB

1016

37

DB

1016

38

Dimensions (mm) Type G50 G51 H20 H21 H22 H23 H42 H43 H44 H45 H46 K25 K35 K36

NS100/160/250N/H/L 137.5 285 62.5 97 45.5 73 60 120 144.5 300 37 156 210.5 300NS400/630N/H/L 180 360 100 152 83 123 60 120 189 378 77 210 282.5 400

Dimensions (mm) Type L31 L32 P7 P8 P9 P32 P33 P50 P52 P54 ØT9 ØT10 U

NS100/160/250N/H/L 110.5 354 25 45 75 178 143 25 99.5 21 9 6 y 32NS400/630N/H/L 150.5 466 25 45 100 250 215 25 123 21 9 6 y 32

Note: coupling accessory: only for changeover systems using fixed versions of Compact NS circuit breakers.

Page 49: Source Changeover

47

Dimensions Remote-operated source-changeover systems 0

Interlocking on a base plate

Compact NS400 to 630Dimensions, 3 or 4 poles Fixed device

DB

1016

39

DB

1016

40

Withdrawable device

Note: coupling accessory: only for changeover systems using fixed versions of Compact NS circuit breakers.

DB

1016

41

(*) Short terminal shields are mandatory.

DimensionsVertical mounting Horizontal mounting

DB

1016

37

DB

1016

38

Note: dimensions see page 46.

Page 50: Source Changeover

48

Dimensions Remote-operated source-changeover systems 0

Interlocking on a base plate

"Normal" and "Replacement" source devices: NS100 to NS250Dimensions Front-panel cut-out

DB

1016

42

DB

1077

44

"Normal" and "Replacement" source devices: NS400 to NS630 Dimensions Front-panel cut-out

DB

1016

44

DB

1077

45

Note for Compact NS:For dimensions with the accessories (IP40 escutcheons and Vigi escutcheon protection collars), see Catalogue Compact.

Page 51: Source Changeover

49

Dimensions Remote-operated source-changeover systems 0

Interlocking on a base plate

NS400 to NS630 as the "Normal" device, NS100 to NS250 as the "Replacement" deviceDimensions Front-panel cut-out

DB

1016

46

DB

1077

46

Page 52: Source Changeover

50

Dimensions Remote-operated source-changeover systems 0

Interlocking using connecting rods

Two Compact NS630b to NS1600 devices one above the otherFixed devices Withdrawable devices

DB

1077

47

DB

1016

55

Two Masterpact NT devices one above the other Fixed devices Withdrawable devices

DB

1016

56

DB

1016

55

Page 53: Source Changeover

51

Dimensions Remote-operated source-changeover systems 0

Interlocking using connecting rods

Two Masterpact NW devices one above the otherFixed devices Withdrawable devices

DB

1077

48

DB

1077

49

Page 54: Source Changeover

52

Dimensions Remote-operated source-changeover systems 0

Interlocking using cables

Two Compact NS630b to NS1600 devices side-by-sideFixed devices Withdrawable devices

DB

1016

61

DB

1016

62

Two Masterpact NT devices side-by-side Fixed devices Drawout devices

DB

1016

63

DB

1016

62

Two Masterpact NT and NW devices side-by-side Fixed devices Drawout devices

DB

1016

64

DB

1016

65

Page 55: Source Changeover

53

Dimensions Remote-operated source-changeover systems 0

Interlocking using cables

Two Masterpact NW devices side-by-sideFixed devices Drawout devices

DB

1016

66

DB

1016

67

Three Masterpact NW devices side-by-side Fixed devices

DB

1016

68

Drawout devices

DB

1016

69

Page 56: Source Changeover

54

Dimensions Remote-operated source-changeover systems 0

Interlocking using cables

Two Compact NS630b to NS1600 devices one above the otherFixed devices Withdrawable devices

DB

1077

50

DB

1016

71

Two Masterpact NT devices one above the other Fixed devices Drawout devices

DB

1016

72

DB

1016

71

Page 57: Source Changeover

55

Dimensions Remote-operated source-changeover systems 0

Interlocking using cables

Two Masterpact NW devices one above the otherFixed devices Drawout devices

DB

1077

51

DB

1077

52

Two Masterpact NT and NW devices one above the otherFixed devices Drawout devices

DB

1077

53

DB

1077

52

Page 58: Source Changeover

56

Dimensions Remote-operated source-changeover systems 0

Interlocking using cables

Three Masterpact NW devices one above the otherFixed devices Drawout devices

DB

1077

54

DB

1077

55

Page 59: Source Changeover

57

Dimensions Remote-operated source-changeover systems 0

IVE electrical-interlocking unitBA and UA automatic controllers

IVE electrical-interlocking unit

DB

1016

79

DB

1016

78

ACP auxiliaries control plate and BA/UA controller Door cut-out for BA/UA controllers

DB

1016

80

DB

1016

81

DB

1016

82

DB

1016

83

(1) Cut-out according DIN 43700 standard.

Page 60: Source Changeover

58

Page 61: Source Changeover

59

Source-changeover systems

Electrical diagrams

Presentation 2Functions and characteristics 7Dimensions 37

Remote-operated source-changeover systems 602 Compact NS100/1600 or Masterpact NT/NW devices 602 Compact NS100/630 devices 612 Compact NS630b/1600 devices 642 Masterpact NT or NW devices 723 Masterpact NW devices 82

Source-changeover systems with automatic controllers 912 Compact NS100/1600 or Masterpact NT/NW devices 912 Masterpact NT or NW devices 94

Catalogue numbers and order forms 95

Page 62: Source Changeover

60

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS100/1600 or Masterpact NT/NW devices

Electrical interlocking by the IVE unitRecommended electrical control system

DB

1016

89

(1) The “normal” and “replacement” source transfer orders must be interlocked electrically.(2) Operating diagram: the SDE “fault-trip” signals are transmitted to the IVE unit. The SDE auxiliary contacts are mounted in the circuit breakers.

LegendsON "Normal” source opening orderOR "Replacement” source opening orderFN "Normal” source closing orderFR “Replacement” source closing orderL1 “Normal” source “fault-trip” signalL2 “Replacement” source “fault-trip” signalN “Normal” source auxiliary wiring connectorR “Replacement” source auxiliary wiring connector

Note: diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 63: Source Changeover

61

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS100/630 devicesDiagram no. 51201177

Source-changeover system without automatic-control systemWithout auxiliaries for emergency off Local reset

DB

1016

86

DB

1016

59

Voluntary remote reset

DB

1016

60

Automatic reset

ATTENTION (1) Prefabricated wiring: cannot be modified.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, reverse the wires connected to terminals 82 and 84.

LegendsQN Normal” source Compact NS equipped with motor mechanismQR “Replacement” source Compact NS equipped with motor

mechanismSDE “fault-trip” indication contactIVE electrical interlocking and terminal block unitMT motor mechanismOF2 breaker ON/OFF indication contactRN reset order for breaker QNRR reset order for breaker QR

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 64: Source Changeover

62

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS100/630 devicesDiagram no. 51201178

Source-changeover system without automatic-control systemWith emergency off by MN release and automatic reset

DB

1125

53

Automatic reset

ATTENTION (1) Prefabricated wiring supplied.(2) Independent auxiliary source.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, reverse the wires connected to terminals 82 and 84.

LegendsQN Normal” source Compact NS equipped with motor

mechanismQR "Replacement” source Compact NS equipped with motor

mechanismMN undervoltage releaseOF2 breaker ON/OFF indication contactSDE “fault-trip” indication contactMT motor mechanismIVE electrical interlocking and terminal block unitBP emergency off button with latchingKA3 auxiliary relayF1 auxiliary power supply circuit breaker

States permitted by mechanical interlocking systemNormal Replacement0 01 0

0 1Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 65: Source Changeover

63

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS100/630 devicesDiagram no. 51201179

Source-changeover system without automatic-control systemWith emergency off by MX release and automatic reset

DB

1016

91

Automatic reset

ATTENTION (1) Prefabricated wiring supplied(2) This source can be:

b the source present in the case of voltage monitoringb an independent source.

In this case, the MX release must be protected.(3) The reset orders must be delayed by 0.3 seconds.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, reverse the wires connected to terminals 82 and 84.

LegendsQN “Normal” source Compact NS equipped with motor

mechanismQR “Replacement” source Compact NS equipped with motor

mechanismSDE “fault-trip” indication contactOF2 breaker ON/OFF indication contactMX shunt releaseMT motor mechanismIVE electrical interlocking and terminal block unitKA1 time-delayed auxiliary relaysKA2 time-delayed auxiliary relaysF1 auxiliary power supply circuit breakerF2 auxiliary power supply circuit breaker

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 66: Source Changeover

64

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201180

Electrical interlocking

DB

1016

93

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 67: Source Changeover

65

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201181

Electrical interlocking with emergency off by shunt release

DB

1016

95

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerMX shunt releaseBP emergency off button with latchingKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 68: Source Changeover

66

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201182

Electrical interlocking with emergency off by undervoltage

DB

1016

97

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerMN undervoltage releaseBP emergency off button with latchingKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR "Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 69: Source Changeover

67

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201183

Electrical interlocking by IVE

DB

1125

54

ATTENTION (1) Not to be wired on fixed version.(2) Prefabricated wiring supplied.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerIVE electrical interlocking and terminal block unitON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1

Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 70: Source Changeover

68

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201184

Electrical interlocking by IVE with emergency off by shunt release

DB

1125

55

ATTENTION (1) Not to be wired on fixed version.(2) Prefabricated wiring supplied.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerIVE electrical interlocking and terminal block unitMX shunt releaseBP emergency off button with latchingKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 71: Source Changeover

69

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201185

Electrical interlocking by IVE with emergency off by undervoltage release

DB

1125

56

ATTENTION (1) Not to be wired on fixed version.(2) Prefabricated wiring supplied.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600MCH spring-charging motorMX standard opening releaseXF standard closing releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerIVE electrical interlocking and terminal block unitMN undervoltage releaseBP emergency off button with latchingKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 72: Source Changeover

70

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201186

Automatic-control system without IVE for permanent replacement source

DB

1017

05

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relays - UN presence detectionKA2 auxiliary relays - UR presence detectionKM1 contactors with 0.25 second delay (for transfer

to “Replacement” source)KM2 contactors with 0.25 second delay (for transfer to “Normal”

source) MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 73: Source Changeover

71

Electrical diagrams Remote-operated source-changeover systems 0

2 Compact NS630b/1600 devicesDiagram no. 51201187

Automatic-control system for replacement source generator set

DB

1017

07

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Compact NS630b to 1600QR “Replacement” source Compact NS NS630b to 1600OF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactCE1 “connected-position” indication contact (carriage switch)F1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relays - UN presence detectionKA2 auxiliary relays - UR presence detectionKA3 auxiliary relays - generator set startup if UN absentKM1 contactors with 0.25 second delay (for transfer

to “Replacement” source)KM2 contactors with 0.25 second delay (for transfer to “Normal”

source)MT Motor Mechanism

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: after a fault trip, the breaker must be reset manually by pressing its reset button.Diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 74: Source Changeover

72

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201139

Electrical interlocking with lockout after a fault

DB

1017

09

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)

States permitted by mechanical interlocking systemNormal Replacement0 01 0

0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 75: Source Changeover

73

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201140

Electrical interlocking with lockout after a fault and emergency off by shunt release

DB

1017

11

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsKA3 time delay for genset startup order to avoid starting

the genset for transient UN disturbancesQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerMX2 shunt releaseBP emergency off button with latchingON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)BP emergency off button with latching

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 76: Source Changeover

74

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201141

Electrical interlocking with lockout after a fault and emergency off by undervoltage release

DB

1017

13

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerBP emergency off button with latchingS1 control switchesKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 77: Source Changeover

75

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201142

Electrical interlocking by IVE with lockout after a fault

DB

1017

15

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN "Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unitF1 auxiliary power supply circuit breakerON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)

States permitted by mechanical interlocking systemNormal Replacement0 01 0

0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 78: Source Changeover

76

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201143

Electrical interlocking by IVE with lockout after a fault and emergency off by shunt release

DB

1017

17

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unitF1 auxiliary power supply circuit breakerBP emergency off button with latchingKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 79: Source Changeover

77

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51201144

Electrical interlocking by IVE with lockout after a fault and emergency off by undervoltage release

DB

1017

19

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unitF1 auxiliary power supply circuit breakerBP emergency off button with latchingS1 control switchesKA3 auxiliary relayON “Normal” source opening orderOR “Replacement” source opening orderFN “Normal” source closing order (0.25 second delay)FR “Replacement” source closing order (0.25 second delay)

States permitted by mechanical interlocking systemNormal Replacement0 01 0

0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 80: Source Changeover

78

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51156226

Automatic-control system without IVE for permanent replacement source with lockout after a fault

DB

1017

21

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relays - UN presence detectionKA2 auxiliary relays - UR presence detectionKM1 contactors with 0.25 second delay (for transfer to

“Replacement” source)KM2 contactors with 0.25 second delay (for transfer to “Normal”

source)

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 81: Source Changeover

79

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51156227

Automatic-control system for replacement source generator set with lockout after a fault

DB

1017

23

ATTENTION (1) Not to be wired on fixed version.

The diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relays - UN presence detectionKA2 auxiliary relays - UR presence detectionKA3 auxiliary relays - generator set startup if UN absentKM1 contactors with 0.25 second delay (for transfer to

“Replacement” source)KM2 contactors with 0.25 second delay (for transfer to “Normal”

source)

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 82: Source Changeover

80

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51156904

Automatic-control system for permanent replacement source with lockout after a fault (with MN)

DB

1125

57

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unitF1 auxiliary power supply circuit breakerF2 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relaysKA2 auxiliary relaysKA3 auxiliary relays

States permitted by mechanical interlocking systemNormal Replacement0 01 0

0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 83: Source Changeover

81

Electrical diagrams Remote-operated source-changeover systems 0

2 Masterpact NT or NW devicesDiagram no. 51156905

Automatic-control system for replacement source generator set with lockout after a fault (with MN)

DB

1125

58

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unitF1 auxiliary power supply circuit breakerF2 circuit breaker (high breaking capacity)S1 control switchesKA1 auxiliary relayKA2 time delay for genset startup order to avoid starting

the genset for transient UN disturbancesKA3 auxiliary relay

States permitted by mechanical interlocking systemNormal Replacement0 01 00 1

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Wiring colour codesRD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 84: Source Changeover

82

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156906

2 Normal sources and 1 Replacement source: electrical interlocking without lockout after a fault

DB

1017

34

LegendsQN... “Normal” source Masterpact NWQR “Replacement” source Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactPF “ready-to-close” contactCE “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakert1 order for transfer from “R” to “N1 + N2”

(QN1 and QN2 closing time delay = 0.25 sec. minimum)t2 order for transfer from “N1 + N2”to “R”

(QR closing time delay = 0.25 sec. minimum)

States permitted by mechanical interlocking systemNormal 1 Normal 2 Replacement0 0 01 1 0

0 0 11 0 00 1 0

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 85: Source Changeover

83

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156907

2 Normal sources and 1 Replacement source: electrical interlocking with lockout after a fault

DB

1017

66

ATTENTIONThe diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN... “Normal” source Masterpact NWQR “Replacement” source Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerS1 control switchesS2 source selection switchest1 order for transfer from “R” to “N1 + N2”

(QN1 and QN2 closing time delay = 0.25 sec. minimum)t2 order for transfer from “N1 + N2”to “R”

(QR closing time delay = 0.25 sec. minimumm)

States permitted by mechanical interlocking systemNormal 1 Normal 2 Replacement0 0 01 1 00 0 1

1 0 00 1 0Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 86: Source Changeover

84

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156908

2 Normal sources and 1 Replacement source: automatic-control system for generator set without lockout after a fault (with MN)

DB

1017

37

LegendsQN... “Normal” source Masterpact NWQR “Replacement” source Masterpact NWMCH spring-charging motorXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesS2 source selection switchesKA1 auxiliary relayKA2 auxiliary relays with 10 to 180 sec. time delayKA3 auxiliary relays with 0.1 to 30 sec. time delayKA4 auxiliary relayKA5 auxiliary relays with 0.25 sec. time delayKA6 auxiliary relays with 0.25 sec. time delay

States permitted by mechanical interlocking system and with associated automatism

Normal 1 Normal 2 Replacement0 0 01 1 0

0 0 11 0 00 1 0

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 87: Source Changeover

85

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156909

2 Normal sources and 1 Replacement source: automatic-control system for generator set with lockout after a fault (with MN)

DB

1017

39

ATTENTIONThe diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQN... “Normal” source Masterpact NWQR “Replacement” source Masterpact NWMCH spring-charging motorXF standard closing voltage releaseMN undervoltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesS2 source selection switchesKA1 auxiliary relayKA2 auxiliary relays with 10 to 180 sec. time delayKA3 auxiliary relays with 0.1 to 30 sec. time delayKA4 auxiliary relayKA5 auxiliary relays with 0.25 sec. time delayKA6 auxiliary relays with 0.25 sec. time delayKA7 auxiliary relayKA8 auxiliary relay

States permitted by mechanical interlocking system and with associated automatism

Normal 1 Normal 2 Replacement0 0 01 1 0

0 0 11 0 00 1 0

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 88: Source Changeover

86

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156910

3 sources with only 1 device closed: electrical interlocking without lockout after a fault

DB

1017

41

LegendsQS... “Source” Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakert1 order for transfer to “Source 1”

(QS1 closing time delay = 0.25 sec. minimum)t2 order for transfer to “Source 2”

(QS2 closing time delay = 0.25 sec. minimum)t3 order for transfer to “Source 3”

(QS3 closing time delay = 0.25 sec. minimum)

States permitted by mechanical interlocking systemSource 1 Source 2 Source 30 0 0

1 0 00 1 00 0 1

Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 89: Source Changeover

87

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156911

3 sources with only 1 device closed: electrical interlocking with lockout after a fault

DB

1017

43

ATTENTIONThe diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQS... “Source” Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakert1 order for transfer to “Source 1”

(QS1 closing time delay = 0.25 sec. minimum)t2 order for transfer to “Source 2”

(QS2 closing time delay = 0.25 sec. minimum)t3 order for transfer to “Source 3”

(QS3 closing time delay = 0.25 sec. minimum)KA1 auxiliary relaysKA2 auxiliary relaysKA3 auxiliary relays

States permitted by mechanical interlocking systemSource 1 Source 2 Source 30 0 01 0 0

0 1 00 0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 90: Source Changeover

88

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156912

2 sources and 1 coupling: electrical interlocking without lockout after a fault

DB

1017

45

LegendsQS... “Source” Masterpact NWQC “Coupling” Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakert1 coupling order for “Source 1 failure”

(QC closing time delay = 0.25 sec. minimum)t2 coupling order for “Source 2 failure”

(QC closing time delay = 0.25 sec. minimum)t3 coupling order for “Source 1 restored”

(QS1 closing time delay = 0.25 sec. minimum)t4 coupling order for “Source 2 restored “

(QS2 closing time delay = 0.25 sec. minimum)

States permitted by mechanical interlocking systemSource 1 Source 2 Coupling0 0 01 1 01 0 1

0 1 11 0 0

0 1 00 0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 91: Source Changeover

89

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156913

2 sources and 1 coupling: electrical interlocking with lockout after a fault

DB

1017

47

ATTENTIONThe diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQS... “Source” Masterpact NWQC “Coupling” Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakert1 coupling order for “Source 1 failure”

(QC closing time delay = 0.25 sec. minimum)t2 coupling order for “Source 2 failure”

(QC closing time delay = 0.25 sec. minimum)t3 coupling order for “Source 1 restored”

(QS1 closing time delay = 0.25 sec. minimum)t4 coupling order for “Source 2 restored “

(QS2 closing time delay = 0.25 sec. minimum)KA1 auxiliary relaysKA2 auxiliary relaysKA3 auxiliary relays

States permitted by mechanical interlocking systemSource 1 Source 2 Coupling0 0 01 1 0

1 0 10 1 11 0 0

0 1 00 0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 92: Source Changeover

90

Electrical diagrams Remote-operated source-changeover systems 0

3 Masterpact NW devicesDiagram no. 51156914

2 sources and 1 coupling: automatic-control system with lockout after a fault

DB

1017

49

ATTENTIONThe diagram shows the electrical wiring for circuit breakers. When wiring the SDE with switch-disconnectors, connect the SDE to terminals 81 and 84.

LegendsQS... “Source” Masterpact NWQC “Coupling” Masterpact NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault trip” indication contactPF “ready-to-close” contactCE... “connected-position” indication contact (carriage switch)CH “springs charged” indication contactF1 auxiliary power supply circuit breakerF2/F3 circuit breaker (high breaking capacity)S1 control switchesS2 source selection switchesKA1 auxiliary relays with 10 to 180 sec. time delayKA2 auxiliary relays with 0.1 to 30 sec. time delayKA3 auxiliary relays with 10 to 180 sec. time delayKA4 auxiliary relays with 0.1 to 30 sec. time delayKA5 auxiliary relays with 0.25 sec. time delayKA6 auxiliary relays with 0.25 sec. time delayKA7 auxiliary relays with 0.25 sec. time delay

States permitted by mechanical interlocking system and with associated automatism

Source 1 Source 2 Coupling0 0 01 1 01 0 1

0 1 11 0 00 1 0

0 0 1Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.Auxiliary power supply = supply voltage of auxiliary relays (KA...) = supply voltage of electrical auxiliaries (electrical operation, MCH, MX, MN...).

Page 93: Source Changeover

91

Electrical diagrams Source-changeover systems with automatic controllers 0

2 Compact NS100/1600 or Masterpact NT/NW devices

Source-changeover system with BA controllerCoupling

DB

1017

51

DB

1017

53

Transfer conditions

DB

1017

55

Terminals 20 and 21: additional control contact (not part of controller).

Tests on “Normal” and “Replacement” source voltagesThe single-phase check for UN and UR is implemented across terminals 1 and 5 of circuit breakers Q1 and Q2.

LegendsQ1 circuit breaker supplying and protecting the automatic-

control circuits for the “Normal” sourceQ2 circuit breaker supplying and protecting the automatic-

control circuits for the “Replacement” sourceACP auxiliaries control plateBA automatic controllerIVE electrical interlocking and terminal block unit

Note: diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 94: Source Changeover

92

Electrical diagrams Source-changeover systems with automatic controllers 0

2 Compact NS100/1600 or Masterpact NT/NW devices

Source-changeover system with UA controllerLoad shedding and genset management

DB

1017

57

DB

1017

58

Transfer conditions

DB

1017

59

Terminals 20 and 21: additional control contact (not part of controller).

Tests on “Normal” and “Replacement” source voltages“Normal” source voltage UN test

DB

1017

61

“Replacement” source voltage UR testThe single-phase check for UR is implemented across terminals 1 and 5 of circuit breaker Q2.

LegendsQ1 circuit breaker supplying and protecting the automatic-

control circuits for the “Normal” sourceQ2 circuit breaker supplying and protecting the automatic-

control circuits for the “Replacement” sourceACP auxiliaries control plateUA automatic controllerIVE electrical interlocking and terminal block unit

Note: diagram shown with circuits de-energised, circuit breakers open and relays in normal position.

Page 95: Source Changeover

93

Electrical diagrams Source-changeover systems with automatic controllers 0

2 Compact NS100/1600 or Masterpact NT/NW devices

Controller settings Using communication functions

DB

1017

62

DB

1017

63Tests on “Normal” source voltageA = 0 single-phase test,A = 1 three-phase test.

Voluntary transfert (e.g. for energy management)b action in the event of genset failureB = 0 circuit breaker N opens,B = 1 circuit breaker N remains closed.b maximum permissible genset startup time (T6)C = 0 T = 120 s,C = 1 T = 180 s.After this time has elapsed, the genset is considered to have failed.

The address of the UA controller is set using the two BBus dials.

Page 96: Source Changeover

94

Electrical diagrams Source-changeover systems with automatic controllers 0

2 Masterpact NT or NW devicesDiagram no. 51156903

Electrical interlocking with lockout after a fault

DB

1017

65

ATTENTION (1) Not to be wired for the “without lockout after a fault” solution.(2) Not to be wired on fixed version.(3) Prefabricated wiring supplied.The diagram shows the electrical wiring for circuit breakers.

When wiring the SDE with switch-disconnectors, connect wire BK to terminal 82.

LegendsQN “Normal” source Masterpact NT or NWQR “Replacement” source Masterpact NT or NWMCH spring-charging motorMX standard opening voltage releaseXF standard closing voltage releaseOF... breaker ON/OFF indication contactSDE1 “fault-trip” indication contactPF “ready-to-close” contactCE1 “connected-position” indication contact (carriage switch)CH “springs charged” indication contactIVE electrical interlocking and terminal block unit

States permitted by mechanical interlocking systemNormal Replacement0 0

1 00 1

Wiring colour codes Note: diagram shown with circuit breakers in connected position, open, charged, and ready to close.

RD GN BK VT YE GY WH BNred green black violet yellow grey white brown

Page 97: Source Changeover

95

Source-changeover systems

Catalogue numbers and order forms

Presentation 2Functions and characteristics 7Dimensions 37Electrical diagrams 59

Source-changeover systems for 2 devices 96Interpact INS40 to INS2500 96Compact NS100 to NS630 97Compact NS630b to NS1600 circuit breakers and switch-disconnectors 99Masterpact NT circuit breakers and switch-disconnectors 101

Source-changeover systems for 2 or 3 devices 102Masterpact NW circuit breakers and switch-disconnectors 102

Source-changeover systems for 2 devices 104Interpact INS40 to INS630 Switch-disconnectors 104Compact NS100 to NS630 / Circuit-breakers and switch-disconnectors 106Compact NS630b to NS1600 / Circuit-breakers and switch-disconnectors 108Masterpact NT or NW / Circuit-breakers and switch-disconnectors 110

Source-changeover systems for 3 devices 112Masterpact NW / Circuit-breakers and switch-disconnectors 112

Page 98: Source Changeover

96

Catalogue numbersand order forms

Source-changeover systems for 2 devices Interpact INS40 to INS2500 and INV100 to INV2500

Manual source-changeover systems Interpact INS40 to INS630 and INV100 to INV630Interlocking for rotary handle

3/4P

DB

1077

10

Mechanical device for INS40 to INS160equipped with an extended rotary handle

28953

E89

624

Mechanical device for INS250-100 to INS250/INV100 to INV250equipped with a direct or extended rotary handle

31073

Mechanical device for INS/INV320 to INS/INV630equipped with a direct or extended rotary handle

31074

Complete assembly source-changeover systems Interpact INS250 to INS6303P 4P

E89

638

With Interpact INS250-100A 31140 31141With Interpact INS250-160A 31144 31145With Interpact INS250-200A 31142 31143With Interpact INS250 31146 31147With Interpact INS320 31148 31149With Interpact INS400 31150 31151With Interpact INS500 31152 31153With Interpact INS630 31154 31155

DB

1077

11

Locking for INS complete source changeover assemblyHandle locking by 1 to 3 padlocks (in OFF position) Built inBy keylock Keylocking device 31097

+ Ronis 1351B.500 keylock 41940or + Profalux KS5 B24 D4Z keylock 42888

E89

617

Rotary handleExtended front control for complete source changeover assembly 31055

Manual source-changeover systems Interpact INS250 to INS2500 and INV250 to INV2500 by keylockInterlocking

3/4P

DB

1015

49

Locking device for Ronis/Profalux keylocks on INS250-100 to INS250/INV100 to INV250

2x 31087

Locking device for Ronis/Profalux keylockson INS/INV320 to INS/INV630

2x 31088

E89

626

Locking device for Ronis/Profalux keylockson INS/INV630b to INS/INV2500

2x 31291

+ Ronis 1351B.500 keylock (2 keylocks / 1 key) 41950or + Profalux KS5 B24 D4Z keylock (2 keylocks / 1 key) 42878

Connection accessoriesDownstream coupling accessories

3P 4P

DB

1010

62

Short terminal shields INS250 (1 pair) 29322 29322INS320 to INS630 (1 pair) 32563 32563

E50

998

"Normal" source /"replacement" source

INS250 29358 29359INS320 to INS630 32619 32620

DB

1010

63

Long terminal shields INS250 (1 pair) 29324 29324INS320 to INS630 (1 pair) 32583 32583

¿5...8

Page 99: Source Changeover

97

Catalogue numbersand order forms

Source-changeover systems for 2 devices (cont.)

Compact NS100 to NS630

Manual source changeoverMechanical interlocking

E21

288

For toggle controlled circuit-breakers NS100...250 29354NS400...630 32614

E18

780

For rotary handled circuit-breakers NS100...250 29369NS400...630 32621

Key lock interlocking

E23

851

For rotary handled or remote controlled circuit breakers2 locks, 1 key Ronis 1351B.500 41950

Profalux KS5 B24 D4Z 42878

Remote controlled source changeoverPlate + IVE

E33

419

Source "normal"/source "replacement" (identical voltages) 24 to 250 V DC 48 to 415 V AC 50/60 Hz440 V 60 Hz

NS100...250/NS100...250Plate + IVE (1) 29351 29350

Plate 29349 29349IVE 29356 29352

Auxiliary switches 2 OF + 2 SDE 4 x 29450 4 x 29450Spare wiring system (device/IVE) 29365 29365Back sockets option add: Only long RC (2) (2)

Plug in base option add: Plug in kit (2) (2)

NS400...630/NS100...630Plate + IVE (1) 32611 32610

Plate 32609 32609IVE 29356 29352

Auxiliary switches 2 OF + 2 SDE 4 x 29450 4 x 29450Spare wiring system (device/IVE) 29365 29365Back sockets option add: Only long RC (2) (2)

Plug in base option add: Plug in kit (2) (2)

Adaptator kit for NS100...250 1 x 32618 1 x 32618Control unit option

E33

420

110/127 V AC 50/60 Hz 220/240 V AC 50/60 Hz 380/415 V AC 50/60 Hz440 V 60 Hz

ACP + control unit BA (1) 29470 29471Plate ACP 29363 29364Control unit BA 29376 29377

ACP + control unit UA (1) 29448 661.42 29472 29473Plate ACP 29447 227.30 29363 29364Control unit UA 29446 434.11 29378 29380

ACP + control unit UA150 (1) (communication option) 29474 29475Plate ACP 29363 29364Control unit UA150 29379 29381

Wiring cable between BA/UA and ACP/IVE29368 29368

(1) The supply voltages BA/UA control unit, ACP plate, IVE and the remote control must be identical whatever the source changeover type.(2) See products pages.

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Page 100: Source Changeover

98

Catalogue numbersand order forms

Source-changeover systems for 2 devices (cont.)

Compact NS100 to NS630 (cont.)

Connection accessoriesDownstream coupling accessories

3P 4P

DB

1010

62

Short terminal shields (1 pair) NS100...250/NS100...250 29321 29322NS400...630/NS400...630 32562 32563

E50

998

Source "normal"/source "replacement"

NS100...250/NS100...250

250 A 29358 29359

NS400...630/NS400...630

630 A 32619 32620

DB

1010

63

Long terminal shields (1 pair) NS100...250/NS100...250 29324NS400...630/NS400...630 32565

Typical composition of remote controlled source changeoverRemote controlled source changeover

E33

422

1 normal device N (1)+ 1 replacement device R (2)+ 2 remote controls (3)

+ 1 plate with interlocking (4) with IVE (5) and its wiring (8)+ 2 plug-in kits (if plug-in version)+ 1 adaptor kit for NS100...250 plug-in (if NS400...630 with NS100...250)

+ auxilary switches (6)2 x (1 OF + 1 SDE) for Compact NS100...630+ 1 downstream coupling accessory (7) for Compact NS100...630 (option)

+ long RC (if back connection)

IVE voltages and remote controls are identical.

Associated control unit

E33

423

1 source changeover without associated control unit

+ 1 ACP (9) with BA control unit (10)Or + 1 ACP (9) with UA control unit (11)Or + 1 ACP (9) with UA150 control unit (11)+ extension (12) for remote UA/BA connection on front of switchboard

IVE voltages + remote control + ACP + BA or UA are identical.

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Page 101: Source Changeover

99

Catalogue numbersand order forms

Source-changeover systems for 2 devices (cont.) Compact NS630b to NS1600 circuit breakers and switch-disconnectors

interlocking for source-changeover systemsMechanical interlocking

E70

744

For 2 devices with extended rotary handles 33890

Interlocking using connecting rods for Compact electrically-operated devices

E72

941

Complete assembly with 2 adaptation fixtures + rods2 Compact fixed devices 339102 Compact withdrawable devices 33913

Interlocking using cables for Compact electrically-operated devices

E72

942

Complete assembly with 2 adaptation fixtures + cables

2 Compact fixed devices 339112 Compact withdrawable devices 339141 Compact fixed + 1 Compact withdrawable device 33915

Opush OFF

Ipush ON

O OFF

discharged

Opush OFF

Ipush ON

O OFF

discharged

Opush OFF

Ipush ON

O OFF

discharged

Opush OFF

Ipush ON

O OFF

discharged

Page 102: Source Changeover

100

Catalogue numbersand order forms

Source-changeover systems for 2 devices (cont.) Compact NS630b to NS1600 circuit breakers and switch-disconnectors (cont.)

Associated controllerThe automatic-control option includes:b an IVE electrical-interlocking unitb an ACP auxiliaries control plateb a BA or UA controller, depending on the required functionsb a UA/BA adapter kit.

Note: the circuit breaker auxiliaries (MCH, MX, XF) and the automatic-control components (IVE, ACP, UA or BA) must have the same voltages.

IVE electrical-interlocking unit 48/415 V AC 50/60 Hz440 V 60 Hz

E88

714

For 2 devices 29352Wiring kit for connection of 2 fixed/withdrawable devices to the IVE unit 54655

Control unit option 110/127 V AC 50/60 Hz 220/240 V AC 50/60 Hz 380/415 V AC 50/60 Hz440 V 60 Hz

E33

420

ACP + control unit BA (1) 29470 29471Plate ACP 29363 29364Control unit BA 29376 29377

ACP + control unit UA (1) 29448 29472 29473Plate ACP 29447 29363 29364Control unit UA 29446 29378 29380

ACP + control unit UA150 (1) (communication option) 29474 29475Plate ACP 29363 29364Control unit UA150 29379 29381

(1) The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system.

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Page 103: Source Changeover

101

Catalogue numbersand order forms

Source-changeover systems for 2 devices (cont.)

Masterpact NT circuit breakers and switch-disconnectors

interlocking for source-changeover systemsInterlocking using connecting rods

E47

760

Complete assembly with 2 adaptation fixtures + rods2 Masterpact NT fixed devices 339122 Masterpact NT drawout devices 33913

Interlocking using cables (*)

Choose 2 adaptation fixtures (1 for each breaker + 1 set of cables)1 adaptation fixture for Masterpact NT fixed devices 332001 adaptation fixture for Masterpact NT drawout devices 332011 set of 2 cables 33209

(*) Can be used with any combination of NT or NW, fixed or drawout devices.

Associated controllerThe automatic-control option includes:b an IVE electrical-interlocking unitb an ACP auxiliaries control plateb a BA or UA controller, depending on the required functionsb a UA/BA adapter kit.

Note: the circuit breaker auxiliaries (MCH, MX, XF) and the automatic-control components (IVE, ACP, UA or BA) must have the same voltages.

IVE electrical-interlocking unit 48/415 V AC 50/60 Hz440 V 60 Hz

E88

714

for 2 devices 29352wiring kit for connection of 2 fixed/drawout devices to the IVE unit 54655

Control unit option 110/127 V AC 50/60 Hz 220/240 V AC 50/60 Hz 380/415 V AC 50/60 Hz440 V 60 Hz

E33

420

ACP + control unit BA (1) 29470 29471Plate ACP 29363 29364Control unit BA 29376 29377

ACP + control unit UA (1) 29448 29472 29473Plate ACP 29447 29363 29364Control unit UA 29446 29378 29380

ACP + control unit UA150 (1) (communication option) 29474 29475Plate ACP 29363 29364Control unit UA150 29379 29381

(1) The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system.

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Page 104: Source Changeover

102

Catalogue numbersand order forms

Source-changeover systems for 2 or 3 devicesMasterpact NW circuit breakers and switch-disconnectors

interlocking for source-changeover systems for 2 devicesInterlocking of 2 devices using connecting rods

E47

762

Complete assembly with 2 adaptation fixtures + rods2 Masterpact NW fixed devices 486122 Masterpact NW drawout devices 48612Can be used with 1 NW fixed + 1 NW drawout.

Interlocking of 2 devices using cables (*)

Choose 2 adaptation fixtures (1 for each breaker + 1 set of cables)

1 adaptation fixture for Masterpact NW fixed devices 479261 adaptation fixture for Masterpact NW drawout devices 479261 set of 2 cables 33209

(*) Can be used with any combination of NT or NW, fixed or drawout devices.

Associated controller for 2 devicesThe automatic-control option includes:b an IVE electrical-interlocking unitb an ACP auxiliaries control plateb a BA or UA controller, depending on the required functionsb a UA/BA adapter kit.

Note: the circuit breaker auxiliaries (MCH, MX, XF) and the automatic-control components (IVE, ACP, UA or BA) must have the same voltages.

IVE electrical-interlocking unit 48/415 V AC 50/60 Hz440 V 60 Hz

E88

714

for 2 devices 29352wiring kit for connection of 2 fixed/drawout devices to the IVE unit 54655

Control unit option 110/127 V AC 50/60 Hz 220/240 V AC 50/60 Hz 380/415 V AC 50/60 Hz440 V 60 Hz

E33

420

ACP + control unit BA (1) 29470 29471Plate ACP 29363 29364Control unit BA 29376 29377

ACP + control unit UA (1) 29448 29472 29473Plate ACP 29447 29363 29364Control unit UA 29446 29378 29380

ACP + control unit UA150 (1) (communication option) 29474 29475Plate ACP 29363 29364Control unit UA150 29379 29381

(1) The supply voltages of the BA/UA controller, ACP plate, IVE unit and circuit breaker operating mechanism must be identical whatever the type of source-changeover system.

interlocking for source-changeover systems for 3 devicesInterlocking of 3 devices using cables

Choose 3 adaptation fixtures (1 complete set with 3 adaptation fixtures + cables) 3 sources, only 1 device closed, fixed or drawout devices 486102 sources, 1 coupling, fixed or drawout devices 486092 normal, 1 replacement source, fixed or drawout devices 48608

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Test

MERLIN GERIN

multi 9

P25M

660V

AC3-IEC292-1

0 . OFF

Page 105: Source Changeover

103

Page 106: Source Changeover

104

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Interpact INS40 to INS630 Switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .

Mechanical interlocking of two INS40 to INS630 devicesDevices with front rotary handles, mounted side by side

Two devices with direct rotary handlesINS250 INS320/400/500/630Two devices with extended rotary handles

INS40/63/80 INS100/125/160INS250 INS320/400/500/630

Downstream coupling accessory

INS250 INS320/400/500/630

Long terminal shields INS250 INS320/400/500/630

Complete source-changeover assemblyINS250-100 A INS250-160 A

INS250-200 A INS250-250 A

INS320 INS400

INS500 INS630

Page 107: Source Changeover

105

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Interpact INS40 to INS630 Switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .(one sheet per device, make copies if necessary)

Indication and measurements4P ammeter module For INS250 Rating 100 A

150 A250 A

Device identification: Adaptation kit required for direct handles

Q 1 - NORMAL SOURCE For INS320/630 Rating 400 A

Q 2 - REPLACEMENT SOURCE 600 A

Switch-disconnector 4P current-transformermodule

For INS250 Rating 100 A

Interpact type INS40/63/80 150 AINS100/125/160 250 A

INS250 For INS320/630 Rating 400 AINS320/400/500/630 600 A

Rating A Auxiliary contact For INS40/160 1OF/CAF/CAO Standard

Number of poles 3 or 4 Low level

Connections For INS250/630 1 OF/CAM Standard

Front connection Standard Low level

Rotary handlesRear connection 2 short 2 long Extended front handles INS40 to INS160 Black Red on yellow frontINS40/80 Distribution 3x16v rigid/10v flexible INS250 Black Red on yellow frontconnectors INS320 to INS630 Black Red on yellow front

INS100/160 Snap-on y 95v For complete changeover assembly INS250connectors Distribution 4x25v rigid/16v flexible INS320/630INS250 Snap-on 1.5v to 95v (< 160 A) Locking of rotary handlesconnectors Snap-on 10v to 185v (< 250 A) Padlocking 1 to 3 padlocks (in OFF position)

Voltage tap connector for 185v connector

Keylocking Keylock adapter (keylock not included)

Keylocks Ronis 1351B.500 Profalux KS5 B24 D4ZClips for connectors Set of 10 Installation accessoriesDistribution 6x1.5v to 35v rigidwith interphase barriers

Front-panel escutcheon For switch-disconnectorsFor ammeter module, IP40

INS320/630 1 cable 35v to 300v

connectors 2 cables 35v to 240v

Voltage tap connector for 185v connector

Distribution "Distribloc" 125 A 160 Ablocks Multi-stage 125 A 160 A

"Polybloc" 160 A 250 ARt-angle extension Set of 3 or 4 250 A 630 AStraight extension INS250

Edgewise ext. INS630Spreader INS250 (45 mm)

Front alignment base

INS320/630 52.5 mm 70 mmOne-piece INS250 INS630

CU cable lugs INS100/160 For 95v cable

supplied with INS250 For 120v cable2 or 3 inter-phase For 150v cablebarriers For 185v cable

INS320/630 For 240v cableFor 300v cable

AL cable lugs INS250 For 150v cable

supplied with For 185v cable2 or 3 inter-phase INS320/630 For 240v cablebarriers For 300v cable

Terminal shrouds INS40/63/80 INS100/125/160Terminal shields INS40/63/80 INS100/125/160

INS250 Short Long

INS320/630 Short LongLong for 52.5 mm spreaders

Interphase INS100/160 Set of 6

barriers INS250 Set of 6INS320/630 Set of 6

Page 108: Source Changeover

106

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Compact NS100 to NS630 / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .

Diagram for two Compact NS devicesWithout automatic control, without emergency off auxiliaries (no. 51201177)

Without automatic control, with emergency off by MN (no. 51201178)Without automatic control, with emergency off by MX (no. 51201179)

Mechanical interlocking of two NS100 to NS630 devices (fixed, plug-in or withdrawable)Manually operated devices, mounted side by side:

Two devices with togglesTwo devices with rotary handles

Mechanical and electrical interlocking of two NS100 to NS630 devices(fixed or plug-in)Electrically operated devices, mounted side by side:Select 1 base plate + IVE, the 4 auxiliary contacts and the options / accessoriesBase plate + IVE Identical voltages: 48 to 415 V AC 50/60 Hz

24 to 250 V DC 440/480 V AC 60 Hz

"Normal" NS100/250 "Replacement" NS100/250"Normal" NS400/630 "Replacement" NS400/630"Normal" NS400/630 "Replacement" NS100/250

Adapter kit for NS400/630 with NS100/250 (plug-in)Auxiliary contacts 2 OF + 2 SDE (mandatory) Quantity Options Long rear connections Plug-in base

Downstream coupling accessory 3P NS100/2504P NS400/630

Prefabricated wiring Between device and IVE Quantity

Automatic-control optionPower supply 220/240 V - 50/60 Hz: ACP + BA controller

ACP + UA controllerACP + UA150 controller

Power supply 380/415 V - 50/60 Hz and 440 V - 60 Hz: ACP + BA controllerACP + UA controllerACP + UA150 controller

4

Page 109: Source Changeover

107

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Compact NS100 to NS630 / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .(one sheet per device, make copies if necessary)

CommunicationCommunicating OF, SD, SDE or SDV auxiliary contactsConnected/disconnected position indication contactsMotor mechanism + communicating OF, SD, SDE contacts 220-240 V 50/60 Hz

Device identification: Indication and measurementsQ 1 - NORMAL SOURCE Ammeter module standard 3P 4P

Q 2 - REPLACEMENT SOURCE I max 3P

Circuit breaker or switch-disconnector Current-transformer module 3P 4P

Compact type NS100/160/250 Insulation-monitoring module 3P 4PNS400/630 Voltage-presence indicator

Rating A Auxiliary contact OF, SD, SDE or SDV Standard Low levelCircuit breaker N, H, L SDE adapter (TM or MA trip units)Switch-disconnector NA Remote operationNumber of poles 2, 3 or 4 Electrical operation Motor mechanism AC DC V Number of poles tripped 2d, 3d, 3dN/2 or 4d Voltage releases Instantaneous MX AC DC V Fixed device Front

connectionsLong rear conn. MN AC DC V

Delayed MN AC DC V Short rear conn. Mixed rear conn. Rotary handles

Plug-in/withdr. Plug-in Withdrawable Direct Black Red on yellow frontEarth-leakage protection ME, MH, MB, MHM MCC conversion access. CNOMO conversion access.

Voltage V Extended Black Red on yellow front4p MB option on 3p NS Telescopic handle for withdrawable device

Thermal-magnetic or electronic trip unit Indication auxiliary 1 early-break switch 2 early-break switches

Thermal-mag.

TMD rating (16 … 250 A) Wiring accessory for early-make switchesTMG rating (16 … 63 A) LockingMA rating (2.5 … 220 A) Toggle (1 to 3 padlocks) Removable Fixed

Electronic STR22 SE GE ME Rotary handle Keylock adapter (keylock not included)STR23 SE SV Keylocks Ronis 1351B.500 Profalux KS5 B24 D4ZSTR53 (basic) UE F SV F Motor mechanism Keylock adapter + Keylocks Ronis (special) NS100/250STR53UE FT FI FTI Keylock adapter (keylock not included) NS400/630ZSI wiring Keylocks Ronis 1351B.500 Profalux KS5 B24 D4ZOption T (rating 150…630 A) A Installation accessoriesSTR43ME F FI Front-panel escutcheon ToggleOption STDAM 110/240 V AC/DC Rotary handle, motor mechanism, escutcheon collar; IP40

24/48 V AC/24/72 V DC Vigi module or ammeter IP40 Vigi moduleCOM wiring Toggle coverSpare battery for STR43 and STR53 Sealing accessories

Connections DIN rail adapter NS100/250

Rear-connect. kit

Short Mixed Plug-in / withdrawable configuration accessoriesAuxiliary connections 1 automatic connector fixed part with 9 wires (for base)

Plug-in kit Compact Vigicompact 1 auto. conn. moving part with 9 wires (for circuit breaker)Withdrawable kit

Compact Vigicompact 1 support for 3 automatic connector moving parts9-wire manual auxiliary connector (fixed + moving)

Long terminal-shield kit for plug-in or withdr. NS400/630 Plug-in base accessories

Long insulated terminals Set of 3 Set of 4Interphase-barrier kit for plug-in or withdr. NS400/630 2 IP4 shutters for baseNS100/250 connectors Snap-on 1.5v to 95v (< 160 A) Chassis accessories Escutcheon collar Toggle Vigi

Snap-on 10v to 185v (< 250 A) Locking kit (keylock not included)Distribution 6 x 1.5v to 35v 2 carriage switches (conn./disconnected position indication)

NS1400/630 connectors 1 cable 35v to 300v Parts of plug-in Plug-in base FC/RC 2P 3P 4P2 cables 35v to 240v Set of two power connections Standard Vigi

Right-angle terminal extensions Safety trip for advanced openingStraight extensions NS100/250 For 3P/4P chassis Moving partEdgewise extensions NS400/630 Fixed partSpreader NS100/250 (one piece) (45 mm)

NS400/630 (52.5 mm) (70 mm)CU cable lugs NS100/250 120v 150v 185v

NS400/630 240v 300v

AL cable lugs NS100/250 150v 185v

NS400/630 240v 300v

Voltage measurement input for connector

for lugs NS100/250 y 185v

for lugs NS400/630Terminal shields

NS100/250 Short LongNS400/630 Short LongLong for 52.5 mm spreaders

Interphase barriers Set of 6Insulation kit > 600 V Without spreadersNS400/630 With 52.5 mm spreaders2 insulatingscreens:

NS100/250NS400/630 52.5 pitch 70 pitch

Page 110: Source Changeover

108

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Compact NS630b to NS1600 / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .

Diagram for two Compact NS devicesElectrical interlocking with lockout after fault:Permanent replacement source (without IVE) (no. 51201180)With emergency off by MX (without IVE) (no. 51201181)With emergency off by MN (without IVE) (no. 51201182)

Permanent replacement source (with IVE) (no. 51201183)With emergency off by MX (with IVE) (no. 51201184)With emergency off by MN (with IVE) (no. 51201185)

Automatic control without lockout after fault:Permanent replacement source (without IVE) (no. 51201186)Engine generator set (without IVE) (no. 51201187)

Interlocking using connecting rods between two NS630b to NS1600 devicesManually operated devices installed side-by-side:

For two fixed NS devices with extended rotary handlesElectrically operated devices installed one above the other:Select a complete set including two adaptation fixtures and the connecting rods

Complete set for: 2 fixed NS devices2 withdrawable NS devices

Interlocking using cables between two NS630b to NS1600 devicesElectrically operated devices installed one above the other or side-by-side:Select a complete set including two adaptation fixtures and the cables

Complete set for: 2 fixed NS devices2 withdrawable NS devices1 fixed NS device + 1 withdrawable NS device

Electrical interlocking between two NS630b to NS1600 devices1 IVE unit 48/415 V - 50/60 Hz and 440 V - 60 Hz1 wiring kit for connection between 2 fixed / withdrawable devices to the IVE unit

Automatic-control optionPower supply 110 V - 50/60 Hz: ACP + BA controller

ACP + UA controller

ACP + UA150 controllerPower supply 220/240 V - 50/60 Hz: ACP + BA controller

ACP + UA controller

ACP + UA150 controllerPower supply 380/415 V - 50/60 Hz and 440 V - 60 Hz: ACP + BA controller

ACP + UA controller

ACP + UA150 controller

Page 111: Source Changeover

109

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Compact NS630b to NS1600 / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .(one sheet per device, make copies if necessary)

Indication contactsSD trip indication (maximum 1)

6 A-240 V AC Low levelSDE fault-trip indication (maximum 1) (SDE integrated in electrically operated devices)

Device identification: 6 A-240 V AC Low level

Q 1 - NORMAL SOURCE OF ON/OFF indication contacts (maximum 3)

Q 2 - REPLACEMENT SOURCE 6 A-240 V AC qty Low level qty

Circuit breaker or switch-disconnector Carriage switches (possible combinations: 3 CE, 2 CD, 1 CT)

Compact type NS630b to NS1600 CE - "connected" position 6 A-240 V AC qty Low level qty Rating A CD - "disconnected" position 6 A-240 V AC qty Low level qty Circuit breaker N, H, L CT - "test" position 6 A-240 V AC qty Low level qty Switch-disconnector NA Auxiliary terminals for chassis alone Jumpers (set of 10)Number of poles 3 or 4 3-wire terminal (30 parts) 6-wire terminal (10 parts)Device Fixed Remote operation

Withdr. chassis Electrical operation Standard CommunicatingWithdr. without chassis(moving part only)

Power supply AC DC V Voltage releases MX AC DC V

Chassis alone without connections MN AC DC V

Micrologic control unit MN delay unit Adjustable Non-adjustableBasic protection 2.0 5.0

A - ammeter Rotary handles for fixed and withdrawable device 2.0 5.0 6.0 7.0 Direct Black Red on yellow front

AD - external power-supply module V CNOMO conversion access.TCE - external sensor (CT) for neutral protection Extended Black Red on yellow frontRectangular sensor 280 x 115 mm Telescopic handle for withdrawable deviceTCW - external sensor for SGR protection Indication auxiliary 6 A-240 V AC 2 early-make switchesLR - long-time rating plug Standard 0.4 to 1 Ir 2 early-break switches

Low setting 0.4 to 0.8 Ir LockingHigh setting 0.8 to 1 Ir Toggle (1 to 3 padlocks) Removable system Fixed systemLT OFF Rotary handle using

a keylockOFF position ON and OFF positions

Communication Ronis 1351B.500 Profalux KS5 B24 D4Z

COM module Jbus/Modbus

Manual operation Keylock kit (without keylock)Electrical operation For electrically operated

devicesVBP - ON/OFF pushbutton locking

Digipact Manual operation OFF position locking:Electrical operation VCPO - by padlocks

Modbus Eco COM module(for switchboard display units)

VSPO - by keylocksKeylock kit (w/o keylock) Profalux Ronis

Connections 1 keylock Profalux Ronis

Horizontal rear connections

Top Bottom 2 identical keylocks, 1 key Profalux RonisChassis locking in "disconnected" position:

Vertical rear connections Top Bottom VSPD - by keylocks Keylock kit (w/o keylock) Profalux RonisFront connections Top Bottom Kirk Castell4x240v bare cable connectors + shields

NS - FC fixed 1 keylock Profalux Ronis2 identical keylocks, 1 key Profalux Ronis

Long connection shields NS - FC fixed 2 keylocks, different keys Profalux RonisVertical-connection adapters

NS - FC fixed, withdr. Optional connected/disconnected/test position lockingVPEC - door interlock On right-hand side of chassis

Cable-lug adapters NS - FC fixed, withdr. On left-hand side of chassisArc chute screen NS - FC fixed VPOC - racking interlockInterphase barriers NS - FC fixed, withdr. VDC - mismatch protection Spreaders NS - FC fixed, withdr. AccessoriesVO - safety shutters on chassis

NS - FC fixed CDM - mechanical operation counterCDP - escutcheonCP - transparent cover for escutcheonOP - blanking plate for escutcheonMounting brackets for fixed NS for mounting on horizontal

plane

Test kits Mini test kit Portable test kit

Page 112: Source Changeover

110

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Masterpact NT or NW / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .

Diagram for 2 Masterpact NT/NW devicesElectrical interlocking with lockout after fault:Permanent replacement source (without IVE) (no. 51201139)With emergency off by MX (without IVE) (no. 51201140)With emergency off by MN (without IVE) (no. 51201141)

Permanent replacement source (with IVE) (no. 51201142)With emergency off by MX (with IVE) (no. 51201143)With emergency off by MN (with IVE) (no. 51201144)

Automatic control without lockout after fault:Permanent replacement source (without IVE) (no. 51156226)Engine generator set (without IVE) (no. 51156227)

Automatic control with lockout after fault:Permanent replacement source (with IVE) (no. 51156904)Engine generator set (with IVE) (no. 51156905)

BA/UA controller (with IVE) (no. 51156903)

Interlocking using connecting rods (NT/NW devices one above the other)Select a complete set including two adaptation fixtures and the connecting rodsComplete set for: 2 drawout NT devices 2 fixed NT devices

2 drawout NW devices 2 fixed NW devices

1 fixed NT device + 1 fixed NW devices1 drawout NT device + 1 drawout NW device

Interlocking using cables (NT/NW devices one above the other or side-by-side)Select two adaptation fixtures (one for each device) and a set of two cablesAdaptation fixture for:(NT/NW fixed and drawout devices may be mixed)

1 fixed NT device qty

1 drawout NT device qty 1 fixed NW device qty

1 drawout NW device qty 1 set of 2 cables (for two devices)

Electrical interlocking 2 appareils NT/NW1 IVE unit 48/415 V - 50/60 Hz and 440 V - 60 Hz1 wiring kit for connection between 2 fixed / withdrawable devices to the IVE unit

Automatic-control optionPower supply 220/240 V - 50/60 Hz: ACP + BA controller

ACP + UA controllerACP + UA150 controller

Power supply 380/415 V - 50/60 Hz and 440 V - 60 Hz: ACP + BA controller

ACP + UA controllerACP + UA150 controller

Page 113: Source Changeover

111

Catalogue numbers and order forms

Source-changeover systems for 2 devices 0

Masterpact NT or NW / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .(one sheet per device, make copies if necessary)

Indication contactsOF - ON/OFF indication contactsStandard 4 OF 6 A-240 V AC (10 A-240 V AC and low-level for NW)Additional 1 block of 4 OF for NW max. 2 qty

Device identification: EF - combined "connected/closed" contacts

Q 1 - NORMAL SOURCE 1 EF 6 A-240 V AC for NW max. 8 qty

Q 2 - REPLACEMENT SOURCE 1 EF low-level for NW max. 8 qty

Circuit breaker or switch-disconnector SDE - "fault-trip" indication contact

Masterpact type NT NW Standard 1 SDE 6 A-240 V ACRating A Additional 1 SDE 6 A-240 V AC 1 SDE Low levelSensor rating A Programmable contacts 2 M2C contacts 6 M6C contactsCircuit breaker N1, H1, H2, H3, L1 Carriage switches 6 A-240 V AC Low levelSwitch-disconnector NA, HA, HF, ES,

HA10 (NW)CE - "connected" position max. 3 for NW / NT qty CD - "disconnected" position max. 3 for NW, 2 for NT qty

Number of poles 3 or 4 CT - "test" position max. 3 for NW, 1 for NT qty Option: neutral on right side AC - NW actuator for 6 CE - 3 CD - 0 CT additionnal carriage switches qty Device Fixed Remote operation

Withdr. chassis Remote ON/OFF MCH - gear motor V Withdr. without chassis(moving part only)

XF - closing voltage release V MX - opening voltage release V

Chassis alone without connections PF - "ready to close" contact Low level

Micrologic control unit 6 A-240 V AC

A - ammeter BPFE - electrical closing pushbutton 2.0 5.0 6.0 7.0 Res - electrical reset option V

P - power meter 5.0 6.0 7.0 RAR - automatic reset optionH - harmonic meter 5.0 6.0 7.0 Remote tripping MN - undervoltage release V AD - external power-supply module V R - delay unit (non-adjustable)TCE - external sensor (CT) for neutral protection Rr - adjustable delay unitRectangular sensor for earth-leakage protection

NT (280 x 115 mm) 2nd MX - shunt release V NW (470 x 160 mm) Locking

LR - long-time rating plug Standard 0.4 to 1 Ir VBP - ON/OFF pushbutton locking (by transparent cover + padlocks)Low setting 0.4 to 0.8 Ir OFF position locking:High setting 0.8 to 1 Ir VCPO - by padlocks LT OFF VSPO - by keylocks Keylock kit (w/o keylock) Profalux Ronis

PTE - external voltage measurement input (required for reverse supply)

Kirk Castell1 keylock Profalux Ronis

BAT - battery module 2 identical keylocks, 1 key Profalux Ronis

Communication 2 keylocks, different keys (NW) Profalux Ronis

Eco COM module Modbus Chassis locking in "disconnected" position:(for switchboard display units) VSPD - by keylocks Keylock kit (w/o keylock) Profalux Ronis

Connections Kirk Castell

Horizontal Top Bottom 1 keylock Profalux RonisVertical Top Bottom 2 identical keylocks, 1 key Profalux RonisFront Top Bottom 2 keylocks, different keys Profalux RonisVertical-connection adapters NT - FC fixed, draw. Optional connected/disconnected/test position lockingCable-lug adapters NT - FC fixed, draw. VPEC - door interlock On right-hand side of chassisArc chute screen NT - FC fixed On left-hand side of chassisInterphase barriers NT, NW fixed, draw. VPOC - racking interlockSpreaders NT fixed, drawout IPA - cable-type door interlock Disconnectable front connection adapter

NW fixed IBPO - racking interlock between crank and OFF pushbutton for NWDAE - automatic spring discharge before breaker removal for NW

Lugs for 240v or 300v cables NT fixed, draw. VDC - mismatch protection VO - safety shutters on chassis

NT, NW AccessoriesCDM - mechanical operation counter

VIVC - shutter position indication and locking

NW CB - auxiliary terminal shield for chassisCDP - escutcheonCP - transparent cover for escutcheonOP - blanking plate for escutcheonBrackets for mounting NW fixed on backplatesTest kits Mini test kit Portable test kit

X

Page 114: Source Changeover

112

Catalogue numbers and order forms

Source-changeover systems for 3 devices 0

Masterpact NW / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .

Diagram for 3 Masterpact NW devices2 "Normal" sources + 1 "Replacement" source:Electrical interlocking without lockout after fault (no. 51156906)Electrical interlocking with lockout after fault (no. 51156907)2 "Normal" sources + 1 "Replacement" source with source selection:Automatic control w/ engine generator set w/o lockout after fault (no. 51156908)Automatic control w/ engine generator set w/ lockout after fault (no. 51156909)3 sources, only 1 device ON:Electrical interlocking without lockout after fault (no. 51156910)Electrical interlocking with lockout after fault (no. 51156911)2 "Normal" sources + 1 coupling:Electrical interlocking without lockout after fault (no. 51156912)Electrical interlocking with lockout after fault (no. 51156913)Automatic control with lockout after fault: (no. 51156914)

Interlocking using cables (NW devices one above the other or side-by-side)Select a complete set including three adaptation fixtures and the cables1 complete set for: 3 sources / 1 device ON, fixed or drawout

2 sources + 1 coupling, fixed or drawout2 sources + 1 replacement source, fixed or drawout

Page 115: Source Changeover

Catalogue numbers and order forms

Source-changeover systems for 3 devices 0

Masterpact NW / Circuit-breakers and switch-disconnectors

To indicate your choices, check the applicable square boxes and enter the appropriate information in the rectangles .(one sheet per device, make copies if necessary)

Indication contactsOF - ON/OFF indication contactsStandard 4 OF 6 A-240 V AC (10 A-240 V AC and low-level)Additional 1 block of 4 OF max. 2 qty

Device identification: EF - combined "connected/closed" contacts

Q 1 - NORMAL SOURCE 1 EF 6 A-240 V AC max. 8 qty

Q 2 - REPLACEMENT SOURCE 1 EF low-level max. 8 qty

Circuit breaker or switch-disconnector SDE - "fault-trip" indication contact

Masterpact type NW Standard 1 SDE 6 A-240 V ACRating A Additional 1 SDE 6 A-240 V AC 1 SDE Low levelSensor rating A Programmable contacts 2 M2C contacts 6 M6C contactsCircuit breaker N1, H1, H2, H3, L1 Carriage switches 6 A-240 V AC Low levelSwitch-disconnector NA, HA, HF CE - "connected" position max. 3 qty Number of poles 3 or 4 CD - "disconnected" position max. 3 qty Option: neutral on right side CT - "test" position max. 3 qty Device Fixed AC - NW actuator for 6 CE - 3 CD - 0 CT additionnal carriage switches qty

Drawout with chassis Remote operationDrawout without chassis(moving part only)

Remote ON/OFF MCH - gear motor V XF - closing voltage release V

Chassis alone without connections MX - opening voltage release V

Micrologic control unit PF - "ready to close" contact Low level

A - ammeter 6 A-240 V AC 2.0 5.0 6.0 7.0 BPFE - electrical closing pushbutton

P - power meter 5.0 6.0 7.0 Res - electrical reset option V H - harmonic meter 5.0 6.0 7.0 RAR - automatic reset optionAD - external power-supply module V Remote tripping MN - undervoltage release V TCE - external sensor (CT) for neutral protection R - delay unit (non-adjustable)Rectangular sensor for earth-leakage protection

470 x 160 mm Rr - adjustable delay unit2eme MX - shunt release V

TCW - external sensor for SGR protection LockingLR - long-time rating plug Standard 0.4 to 1 Ir VBP - ON/OFF pushbutton locking (by transparent cover + padlocks)

Low setting 0.4 to 0.8 Ir OFF position locking:High setting 0.8 to 1 Ir VCPO - by padlocks LT OFF VSPO - by keylocks Keylock kit (w/o keylock) Profalux Ronis

PTE - external voltage measurement input (required for reverse supply)

Kirk Castell1 keylock Profalux Ronis

BAT - battery module 2 identical keylocks, 1 key Profalux Ronis

Communication 2 keylocks, different keys (NW) Profalux Ronis

Eco COM module Modbus Chassis locking in "disconnected" position:(for switchboard display units) VSPD - by keylocks Keylock kit (w/o keylock) Profalux Ronis

Connections Kirk Castell

Horizontal Top Bottom 1 keylock Profalux RonisVertical Top Bottom 2 identical keylocks, 1 key Profalux RonisFront Top Bottom 2 keylocks, different keys Profalux RonisInterphase barriers Fixed, drawout Optional connected/disconnected/test position lockingDisconnectable front connection adapter

Fixed VPEC - door interlock On right-hand side of chassisOn left-hand side of chassis

VO - safety shutters on chassis VPOC - racking interlockVIVC - shutter position indication and locking IPA - cable-type door interlock

IBPO - racking interlock between crank and OFF pushbutton for NWDAE - automatic spring discharge before breaker removal for NWVDC - mismatch protection

AccessoriesCDM - mechanical operation counterCB - auxiliary terminal shield for chassisCDP - escutcheonCP - transparent cover for escutcheonOP - blanking plate for escutcheonBrackets for mounting NW fixed on backplatesTest kits Mini test kit Portable test kit

X

Page 116: Source Changeover

Schneider Electric Industries SAS89, boulevard Franklin RooseveltF - 92500 Rueil-Malmaison (France)Tel : +33 (0)1 41 29 85 00

http://www.schneider-electric.comhttp://www.merlin-gerin.comhttp://www.schneider-electric.co

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

Printed on recycled paper.

Design: Schneider ElectricPhotos: Schneider ElectricPrinted: JPF - Imprimerie du Pont de Claix - Made in France

09-2007ABTED201149EN

AR

T29

770

© 2

007

- S

chne

ider

Ele

ctric

- A

ll rig

hts

rese

rved

0