SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer...

28
1 Replacement of 11 kV post / disc insulator. No. Yes 1 2 Attending fault on 11 kV post / disc insulator. No. Yes 1 3 Replacement of 11 kV Lightning arrestors No. Yes 1 4 Replacement of 11 kV fuses indoor / outdoor type. No. Yes 1 5 Replacement of Jumpers of all aluminium conductor incl. proper binding etc No. Yes 1 6 Attending fault on Jumpers of all aluminium conductor incl. proper binding etc No. Yes 1 7 Replacement of ACSR Ferret(HT) conductor and guard wire. span Yes 1 8 Repair / Jointing of broken ACSR Ferret(HT) conductor and guard wire. span Yes 1 9 Replacement of guard cross wire on HT line. No. Yes 1 10 Repair or rectification of guard cross wire on HT line No. Yes 1 11 Replacement of 11 KV gang operated switch/11kV load break switch. set Yes 1 12 Complete maintenance and adjustment of 11 KV gang operated switch/11kV load break switch panel and jumper insulators & all accessories, repair,rectification or replacement of an part of above, cleaning of all these insulators and contacts. set Yes 1 13 Removal of sag of conductors of HT line. span NA 1 14 Tightening of terminal connections and clamps etc. No. NA 1 15 Dismantling of HT over head lines. span NA 1 16 Checking, cleaning and tightening of overhead line insulators including rectification and binding of the conductor with the insulator. No. NA 1 17 Digging out of HT (11/ 3.3 kV) cable of all sizes from ground and re-filling the earth. Mtr NA 20 18 Removal of HT (11/ 3.3 kV)cables from Trench/Trays/ pipes structure etc. Mtr NA 47 19 Digging and removal of old damaged cable in ground & laying of new cable. Mtr Yes 22 20 Removal /Re-laying of HT cable (11/ 3.3 kV) from / in ground as desired by the Engr. in charge. Mtr NA 20 21 Removal / Re-laying of HT cable (11/ 3.3 kV) from / in trench/ trays/ pipe structure etc. Mtr NA 20 22a Straight through / end jointing with heat shrinkable kit. 11KV (UE) / 3.3 KV (UE) grade. No. Yes 2 22b Straight through / end jointing with epoxy kit. 11KV (UE) / 3.3 KV (UE) grade. No. Yes 1 23 Laying of HT cable (11 kV) as per specifications. Mtr NA a Alongwith wall, in trench or on trays. NA 20 b Underground with supply of brick lining. NA 20 * Mat'l to be supplied by NFL SOR Item No. DESCRIPTION OF ITEMS Unit Estimated Qty. Rate (In Fig.)

Transcript of SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer...

Page 1: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

1 Replacement of 11 kV post / disc insulator. No. Yes 1

2 Attending fault on 11 kV post / disc insulator. No. Yes 1

3 Replacement of 11 kV Lightning arrestors No. Yes 1

4 Replacement of 11 kV fuses indoor / outdoor type. No. Yes 1

5Replacement of Jumpers of all aluminium conductor

incl. proper binding etcNo. Yes 1

6Attending fault on Jumpers of all aluminium conductor

incl. proper binding etcNo. Yes 1

7Replacement of ACSR Ferret(HT) conductor and guard

wire. span Yes 1

8Repair / Jointing of broken ACSR Ferret(HT) conductor

and guard wire. span Yes 1

9 Replacement of guard cross wire on HT line. No. Yes 1

10 Repair or rectification of guard cross wire on HT line No. Yes 1

11Replacement of 11 KV gang operated switch/11kV load

break switch.set Yes 1

12

Complete maintenance and adjustment of 11 KV gang

operated switch/11kV load break switch panel and jumper

insulators & all accessories, repair,rectification or

replacement of an part of above, cleaning of all these

insulators and contacts.

set Yes 1

13 Removal of sag of conductors of HT line. span NA 1

14 Tightening of terminal connections and clamps etc. No. NA 1

15 Dismantling of HT over head lines. span NA 1

16Checking, cleaning and tightening of overhead line

insulators including rectification and binding of the

conductor with the insulator.

No. NA 1

17Digging out of HT (11/ 3.3 kV) cable of all sizes from ground

and re-filling the earth.Mtr NA 20

18Removal of HT (11/ 3.3 kV)cables from Trench/Trays/ pipes

structure etc.Mtr NA 47

19Digging and removal of old damaged cable in ground &

laying of new cable.Mtr Yes 22

20Removal /Re-laying of HT cable (11/ 3.3 kV) from / in ground

as desired by the Engr. in charge. Mtr NA 20

21Removal / Re-laying of HT cable (11/ 3.3 kV) from / in trench/

trays/ pipe structure etc.Mtr NA 20

22aStraight through / end jointing with heat shrinkable kit. 11KV

(UE) / 3.3 KV (UE) grade. No. Yes 2

22bStraight through / end jointing with epoxy kit. 11KV (UE) /

3.3 KV (UE) grade. No. Yes 1

23 Laying of HT cable (11 kV) as per specifications. Mtr NA

a Alongwith wall, in trench or on trays. NA 20

b Underground with supply of brick lining. NA 20

* Mat'l to

be

supplied

by NFL

SOR

Item No. DESCRIPTION OF ITEMS UnitEstimated

Qty.Rate (In Fig.)

Page 2: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

24 Painting of poles (HT) .(Paint in contractor's scope) No. NO 86

25Digging out/removal of poles from concrete foundation

alongwith stay set wherever applicable.No. NA 200

26 Erection of pole (supply NFL's scope) No. NA 200

27 Erection of stay sets as per specifications. No. NO 1

28 Rectification of stay sets as per specifications. No. NO 1

29 Erection/replacement of cross arms on the pole. No. NO 1

30 Rectification ofcross arms on the pole. No. NO 1

31 Replacement of 132 kV LA, CT or PT. No. Yes 2

32 Replacement of 132 KV jumpers. No. Yes 2

33Cleaning/ checking of one stack of insulator of MOCB, CT,

PT, LA, Transformer bushing, isolator in 132 kV switch yard.No. NO 1288

34

Cleaning of radiator tubes of HT motors in plant.

Contractor's technician shall strictly follow all safety

precautions as per instructions of NFL's supervisor. All

materials like round brushes etc in the scope of the

contractor.

No. Man day 143

35 Replacement of 132 kV insulator stack. No. Yes 1

36Attending fault / tightening / checking of 132 kV LA, CT,PT,

jumpers or insulator stack.No. Yes 75

37Cleaning/ checking for any abnormality of one stack of string

/ suspension / strain type insulators on 132 kV towers. No. NA 1034

38Attending fault in 5A/15A socket, switch, plug top etc point

incl. tightening of connections, replacement of socket or No. yes 25819

39 Attending fault in 10/20 A plug socket, metal clad socket. No. NO 747

40 Replacement of 10/20 A plug socket, metal clad socket. No. yes 404

41Fuses (re-wirable) of all rating incl. tightening of connections

wherever reqd. incl. removal of burnt /damaged fuses

cleaning etc

No. NO 2220

42Replacement of Kit kat, HRC fuse base & carrier incl.

tightening of connections.No. yes 739

43Attending fault in Kit kat, HRC fuse base & carrier incl.

tightening of connections and replacement of rewireable

fuses.

No. NO 811

44Repalement of M.C.B.(Miniature circuit Breaker) all rating

incl. removal of burnt and replacement with new incl.

connections, tightening wherever reqd.

a MCB single pole of any rating. No. yes 446

b MCB, 3/4 pole any rating No. yes 213

45Replacement of DB/ SPN/ TPN/ TPDB of all rating including

replacement of components and tigtening of connections.No. yes 96

46Attending fault in DB/ SPN/ TPN/ TPDB of all rating

including tigtening of connections.No. yes 4228

47

Attending fault in fan point wiring incl. tightening of

connections, replacement of any or all the components like

switch, regulator selector switch or resistance for speed

variation etc.wherever reqd

No. yes 9643

48Attending fault in light point incl. replacement of any or all

the components like holder, bracket, switch, shade or their

rectification etc. wherever reqd.

No. yes 30615

Page 3: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

49Rectification of fault of bell/buzzer incl. replacement or

repair of replacement of any or all the components likeBell,

Buzzer, switch, wire lead tightening etc. wherever required.

No. yes 2639

50

Rectification of fault in Heater/Hot plate incl. repair or

replacement of any or all the components like element, plug

top, wirelead and tightening of connections, taping etc. as

per requirement.

No. yes 1541

51

Replacement of wire mesh of size 480 x 400 mm inexisting

M.S.frame provided in the hole of kitchen exhaust fan. Wire

mesh should be of 140G with wire dia of 0.71 Sq.mm. The

M.S.frame is to be fixed back after grouting 75x6mm size

M.S. bolt. Wire mesh, nuts and bolts to be supplied by the

contractor.

No. NO 207

52Cleaning of wire mesh of Exhaust fan provided in the

kitchen / plants and public building. No. NA 1342

53Attending fault in lighting, power or telephone circuits as

required including replacement of telephone sets, rossets

and rectification in field junction boxes.

No. NA 9290

54Cleaning of light fixtures of all types, lamp shades/ Hylem

sheets of any size, incl.removal & refixing of cover/louvres

etc.

No. NA 3969

55

Rectification of fault in Heat Convector/ Geyser incl.

replacement of element (supply in NFL's scope),

thermostat, wireleads, bushes, washers, gaskets etc (supply

in contractor's scope) repair or replacement exculding

rewinding of motor for heat convector and excluding

plumbing work in case of Geyser.

No. yes 298

56 Replacement in public buildings/ offices of :-

a Lamps of all sizes No. yes 1937

b Tubes rods 20/40/65 Watts No. yes 2751

57

Renovation of ceiling/wall mounted tube light fitting,

replacement of tube rods,starter chokes, Holders,

condensor, incl.tightening of connections, etc. wherever

necessary,in public building / plant offices.

No. yes 5142

58Replacement of board and Bakelite/ Hylem/ Sunmica sheet

of switch board.No. NO

a Board Sizes upto 5"x8". 236

b Board Sizes above 5"x8". 94

59Rectification of fault of switch board and Bakelite/ Hylem/

Sunmica sheet.No. NO

a Board Sizes upto 5"x8". 4279

b Board Sizes above 5"x8". 1292

60Replacement of Bakelite/ Sunbmica/ Hylem Sheet

incl.cutting and fixing etc.No. NO 127

61Replacement of Round Block / ceiling rose.(supply in party"s

scope)No. NO 74

62Attending fault in Round Block / ceiling rose.(supply in

party"s scope)No. NO 580

63Removal /re-fixing and to and fro safe transportation to

factory complex and back of Energy Meter including taping

of all wires.

No. NA 232

64

Removal, to and fro transportation (factory to township or

within township), refixing , cleaning and trial run of ceiling fan/

kitchen fan/ Air circulators/ Exhaust fans or any other single

phase induction motor.

No. NO 110

Page 4: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

65Removal, refixing, painting and to and fro transportation of

ceiling fan (paint in contractr's scope) as per specs. No. NA 69

66Overhauling of ceiling fans incl.greasing and replacement of

bearing, capacitor, removal, refixing, cleaning & giving its

satisfactory trial run.

No. yes 370

67Attending fault in ceiling fan, checking and Replacement of

split pins, rubber bush, etc as per requirement and cleaning

of ceiling fans.

No. NO 580

68

cleaning and checking for abnormality of ceiling fans incl

removal, complete dismantling, checking of all parts for their

integrity incl bush / bearing, assembly, refixing and taking

trial run.

No. NA 1187

69

Painting of numbers & letters on ceiling fans/ pannels/

DBs/ Poles/light fittings etc. as required. Paint brush &

stencil etc.to be supplied by contractor. Paint will be

approved by Engineer -in-Charge.

a Size :up tp 50 mm letter/number No. NA 2910

b Size up to 200 mm letter/number No. NA 1

70a Replacement of L.T. Line insulators. No. yes 1

70bReplacement of Jumpers of all aluminium conductor

including proper binding etc.No. yes 58

71aAttending fault in L.T. Line insulators, cleaning and binding

etc..No. NA 356

71bAttending faul in Jumpers of all aluminium conductor

including proper binding etc.No. NA 238

72aReplacement of all Aluminium conductor COCKROACH

(19/4.22mm).span yes 7

72b do WASP (7/4.39mm), ANT (7/3.10) and earth wire. span yes 1

73aJointing /repair of broken all Aluminium conductor

COCKROACH (19/4.22mm).span NA 5

73b do WASP (7/4.39mm), ANT (7/3.10) and earth wire. span NA 1

74 Dismantling of LT O/H Lines. Span NA 2

75 Replacement of cage guard on LT Lines. No. yes 2

76 Repair, rectification of cage guard on LT Lines. No. yes 181

77Digging out/removal of pole including stay wire, cross arms,

insulators etc from concrete foundations.No. NA 6

78Erection of Stay Sets as per specifications and tightning of

connections. sets yes 3

79Rectification of Stay Sets as per specifications and tightning

of connections. sets yes 2

80aErection of poles (Supply NFL's scope) as per

specifications. incl. Foundation, digging, and concreting etc.

(Contractor's scope).

No. NA 7

80bRepair of Poles includig necessary welding, civil jobs

digging,muffing etc and supply of material.No. NA 120

81 Erection/replacement of cross arms etc on the poles. No. yes 1

Page 5: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

82

Painting of poles with Redoxide primer one coat & two coat

of Al. paint incl numbering of poles with stencil and paint.

Paint must confirm to Indian Standard specifications. Paint

and other materials to be supplied by the contractor.

No. NA 329

83

Replacement / installation of pole mounting junction boxes

on service lines /street light poles or tele Junction box with

frame, incl. removal of old box if any, connections of all

incoming & outgoing cables/replacement of damaged burnt

kit-kat or neutral link. Complete rectification, wrapping of

plastic polyethylene sheet covers in order to protect from

ingress of rain water as required by Engr.-in-charge. Petty

materials to be provided by the contractor.

No. yes 80

84

Attending fault in pole mounting junction boxes on service

lines /street light poles incl. connections of all incoming &

outgoing cables/replacement of damaged burnt kit-kat or

neutral link. Complete rectification, wrapping of plastic

polyethylene sheet covers in order to protect from ingress

of rain water as required by Engr.-in-charge. Petty

materials to be provided by the contractor.

No. yes 1058

85Cable connection or disconnction of armoured cable.

Reglanding (same gland), if required, is in the scope of the

contractor.

a cable sizes: up to 120 sq mm No. NO 1794

b Cable sizes: above 120 sq mm to 400 sq mm. No. NO 128

86

Glanding of cables including removal of old gland and

termination. Supply of double compression gland and lugs of

reputed make as approved by engr-in-charge will be in the

scope of the contractor.

No. NO

a cable sizes below 120 sq mm(3/4 core) No. 122

b cable sizes from 120 sq mm(3/4 core) up to 400 sq mm No. 68

87 Removal of sag of all conductors of LT line all sizes . span NA 2

88 Tightening of clamps. No. NA 1

89

Straight through/end cable jointing with heat shrinkable kits

suitable for 1.1KVgrade LT Cables of Raychem/M-

Seal/Denson/3-M make. Jointer shall be trained and hold

valid certifcate . Supply of joint as well as all other materials

in the scope of the contractor.

No. NO

a cable size upto 95 mm2 (3/4 core) No. 3

b cable size above 95 mm2 below 240 mm2 (3/4 core) No. 3

c cable size above 240 mm2 (3/4 core) No. 1

d Tele cable 101 pair No. 1

e Tele cable 51 pair No. 1

f Tele cable 21 pair No. 1

90

Straight through/end cable jointing with Epoxy jointing kits

Suitable for 1.1 Kv grade LT Cables of reputed make as

approved by engr-in-charge. Supply of joint as well as all

other materials in the scope of the contractor.

No. NO

a cable size upto 95 mm2 (3/4 core) No. 20

b cable size upto 240 mm2 (3/4 core) No. 5

Page 6: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

c cable size above 240 mm2 (3/4 core) No. 1

91Replacement of PVC wire(NFL's scope) in wooden batton/

conduit/ PVC pipe/ PVC casing capping(contractor's scope)

including connections.

Mtr NA 4801

92aTemporary supply connections and dismantling of 24 volt

hand lamp & extension board as desired by the Engr. in

charge

No. yes 2209

92bTemporary provision of Flood Light / halogen fitting &

extension boardNo. yes 2114

92c Temporary laying of Flexible cables of any size Mtr. yes 31403

92d Laying of unarmoured telephone cables of 1/2/6 pair. Mtr. yes 7511

93aDigging out of LT cable of all sizes and re-filling the earth.

Cable (to be rolled on to drum) and bricks lining to be

transported as desired by Engr.-in-charge

Mtr NA 20

93bDigging out of LT cable and of all sizes and re-laying of the

same cable, underground with supply of brick lining as per

specifications.

Mtr. yes 527

94Laying of LT /HT cable (Cable to be supplied by NFL. All

other materials like clamping materials, bricks, sand,

cement etc. in contractor's scope.)

Mtr.

a1

Alongwith wall, pole or in trench including proper

clamping etc. (In case of laying in trench, removal and

replacement of slabs before and after the job is to be done

by the contractor.) Cable size up to 95mm2

Mtr. NA 5000

a2

Alongwith wall, pole or in trench including proper

clamping etc. (In case of laying in trench, removal and

replacement of slabs before and after the job is to be done

by the contractor.) Cable size above 95 to 240mm2

Mtr. NA 5500

a3

Alongwith wall, pole or in trench including proper

clamping etc. (In case of laying in trench, removal and

replacement of slabs before and after the job is to be done

by the contractor.) Cable size above 240 to 400mm2

Mtr NA 500

b1Underground with supply of brick lining Cable size up to

95mm2Mtr NA 2000

b2Underground with supply of brick lining Cable size above

95 to 240mm2Mtr NA 1000

b3Underground with supply of brick lining Cable size above

240 to 400mm2Mtr yes 250

c

Digging and removal of old damaged cable and laying of

new cable, incl. additional supply of sand and bricks as

desired by Engr.-in-Charge. Old Cable to be rolled on to

drum and transported as desired by the Engr-in-charge

Mtr NA 80

d1Laying under ground in RCC/PCC covered area (6-8 Inch

thick) including making good and restoring to original cable

size up to 95mm2

Mtr NA 20

d2Laying under ground in RCC/PCC covered area (6-8 Inch

thick) including making good and restoring to original cable

size above 95 to 240mm2

Mtr NA 15

d3Laying under ground in RCC/PCC covered area (6-8 Inch

thick) including making good and restoring to original cable

size above 240 to 400mm2

Mtr NA 5

e1

Laying of cable by chipping in wall/ PCC floor upto a depth

of 3 inches. Laying and fastening of cable by catcher etc.

Providing cement, making good and restoring to oiginal incl

supply of all meterials.cable size up to 95mm2

Mtr NA 72

Page 7: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

e2

Laying of cable by chipping in wall/ PCC floor upto a depth

of 3 inches. Laying and fastening of cable by catcher etc.

Providing cement, making good and restoring to oiginal incl

supply of all meterials.cable size above 95 to 240mm2

Mtr NA 40

e3

Laying of cable by chipping in wall/ PCC floor upto a depth

of 3 inches. Laying and fastening of cable by catcher etc.

Providing cement, making good and restoring to oiginal incl

supply of all meterials.cable size above 240 to 400mm2

Mtr yes 24

fRemoval & replacement of Trailing Cables of EOT

cranes/Paddle feeders drives etc. as per scope.Mtr yes 126

g

Laying of UTP cable on wall, pole, columns, structure etc in

PVC pipe (3/4" dia) incl proper clampimg etc. Cable will be

supplied by NFL; All other materials like PVC pipe, clamps,

saddles etc in contractor's scope.

Mtr yes 400

95

Removal of cable from Trench / Trays / pipe

structures.(Removal & replacement of slabs etc. before &

after the job is to be done by the contractor. Cable to be

rolled on to drum and transported as desired by the Engr-in-

charge.

Mtr yes 9236

96Dressing and clamping of LT cable on Trays/walls up to 10

cables per tray. Supply of materials like clamps, nylon thread

and civil & welding jobs will be in the scope of the contractor.

Mtr. NA 3233

97aRemoval and replacing of cable trench covers up to trench of

width 1 mtr. No. NO 1061

97bRemoval and replacing of cable trench covers up to trench of

width above 1 mtr. No. NO 750

98Complete checking and cleaning of switches on LT

panels incl. Bus-ductNo. NO 8

99

Replacement of Star-Delta starter upto any kW Motor.

Removal of old one and burnt parts, if any, disconnection/

connection of cables, earth connections, insulation taping,

proper contacts tightening etc. as required and

approved by Engineer-in-Charge. Any civil or welding job

reqd shall be in the scope of the contractor.

No. NO 2

100

Rectification of fault of Star-Delta starter including

tightening of connections and replacement of any or all

components like contactors/relays/ timers etc upto any kW

Motor. Removal of burnt parts, if any, insulation taping,

proper contacts tightening etc. as required and

approved by Engineer-in-Charge.

No. NO 28

101

Replacement of DOL starter / photocell upto any kW motor.

Removal of old one and burnt parts, if any, disconnection/

connection of cables, earth connections, insulation taping,

proper contacts tightening etc.as required and approved by

Engineer-in-Charge. Any civil of welding job reqd shall be in

the scope of the contractor.

No. 14

102

Rectification of fault of DOL starter/photocell including

tightening of connections and replacement of any or all

components like contactors/relays/ timers etc upto any kW

Motor. Removal of burnt parts, if any, insulation taping,

proper contacts tightening etc. as required and

approved by Engineer-in-Charge.

No. NO 202

Page 8: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

103To and fro safe transportation of 50/15 KW motor of

Sewerage pump house from site to factory and back.

Dismantling and re-fixing of motor.

No. NO 2

104aSupply and erection of earth pit as per IS:3043 - 1966,

including supply of GI pipe 40 mm dia, 2.5 mtr. long,

charcoal, salt etc. to make a complete earthing system.

No. NO 10

104bSupply and erection of earth pit as per drawings in detail

specs and other specs as per IS:3043 - 1966, including

supply of GI pipe 100 mm dia, 3.8 mtr. long, charcoal, salt

No. NO 5

104c

Supply and erection of earth pit in RCC/PCC covered area (6-

8 Inch thick) including making good and restoring to original

as per drawings in detail specs and other specs as per

IS:3043 - 1966, including supply of GI pipe 100 mm dia,

3.8 mtr. long, charcoal, salt etc. to make a complete

earthing system.

No. NO 20

104dModification of existing small sized earthing pits as per

IS:3043-1966 ID 600mm , depth 400mm, and width 125mmNo. No 1

105 Testing and Maintenance of earth pit as per detail scope No. 1029

106

Painting of junction boxes/DB/ Tel.boxes etc.(Paint must

be ISI Marked as appd.by Engr. -in-Charge and to be

supplied by the contractor.( 1 coat of primer & 2 coat of

paint will be done).

Sqmr NO 1

107 Painting of motors with epoxy paint. NO

a size 0 - 22 kW No. NO 1

b size 23 - 160 kW No. NO 1

c size 161 kW and above No. 1

108a

Laying, fixing & termination of 6/8 SWG G.I. wire / Al. strip

(NFL's scope)of any size in existing RCC walls/tray or any

other structures, etc. incl. Supply of hardware like clamps,

bolts etc.and related civil & welding jobs (Contractor's scope)

Mtr NO 20

108b do underground Mtr NO 20

109Wiring for light point with 1.5 sq.mm.PVC insulated Cu

conductor cable.NO

a Short point No. NO 300

b Medium point No. 134

c Long point No. NO 219

d Extra long point No. NO 100

110Wiring for fan point with 1.5 sq.mm PVC insulated, Cu

conductor cable.

a Short point No. NO 27

b Medium point No. NO 77

c Long point No. NO 70

d Extra long point No. 1

111Wiring for call bell point with 1.5 sq.mm. PVC insulated, Cu

conductor cable.(Buzzers in contractor"s scope)NO

a Medium point No. NO 40

Page 9: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

b Long point No. NO 21

112Wiring for 3 pin 5 Amps. plug point with 1.5 sq.mm PVC

insulated, Cu conductor cable.

a Short point No. NO 152

b Medium point No. NO 27

c Long point No. 117

113Wiring for 3/5 pin,15 Amp. power plug with 4 /2.5 sq.mm

PVC insulated, Cu conductor cable.NO

a Short point No. NO 30

b Medium point No. NO 36

c Long point No. NO 122

114Wiring for main/ sub-main with PVC insulated, Cu conductor

cable.NO

a With 2x2.5 sq mm cable. Mtr NA 1664

b With 2x4 sq mm cable. Mtr NA 538

115 Renovation of O/H, street light fixtures / aviation lights NA

a 2x20 / 2x40 /2x65 /4x20 /4x40 Watt tube light fixtures No. NA 5920

b 200 W bulk head fittings No. yes 1313

c200 Watt Well glass fittings, all wattage of HPMV/HPSV

lamps fittings.No. NO 998

d Aviation light on the prilling tower/boiler chimney /flare stack. No. 42

116Shfting of ladders from plant to plant, within plant or within

t/shipNo. 757

117 Holding of ladders of size up to 30'. Hrs 490

118Erection and dismantling of scaffolding. Size: 30 sq ft area

and upto 30 ft height. Including to and fro transportation from

site to store.

No. 1

119

Replacement of Tower light fitting. Connection/

disconnection of cables, tightening of connections, etc. as

required. Any civil jobs or welding jobs reqd shall be in the

scope of the contractor.

No. 1

120Rectification of fault in Tower light fitting, tightening of

connections, replacement of all or any of the components

like lamp, choke, capacitor, ignitor etc. as required

No. yes 163

121

Maintenance of flame proof light fitting which includes

opening the light fixtures, replacement /cleaning of glass

covers if necessary, replacement of switches, re-laying of

cables, replacement of junction boxes, replacement of

cable gland lamp holder, choke and terminal block wherever

required up to 30 ft height in plant area.

No. 350

122

Rectification in of O/H, street Light fixture, aviation light

including replacement of rod/lamp, starter, lamp holder,

supporting structure wherever reqd. in plant/township, as

desired by Engr. in charge. (welding jobs will be in the scope

of the contractor)

No.

a 2x40/2x65 Watt tube light fixture No. 1783

b 200 Watt Wall glass fittings No. 902

c 500/1000 W Flood Light Fitting No. yes 871

d Of all wattage of Mercury/Sodium vapour lamps fittings. No. NO 3222

e Aviation light on the prilling tower/boiler chimney /flare stack. No. NO 40

Page 10: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

123Installation of cable trays as reqd. by Engr-in-Charge

including welding/ cutting /civil works.Mtr Yes

a Cable tray upto 300 mm Mtr NO 240

b Cable tray from 301 to 700 mm Mtr 123

c do but from 701 to 1500 mm Mtr 20

dReplacement of cable tray of size upto 1000mm incl.

handling of cable on it. Mtr NO 20

124Installation of push button station. Welding of supprt

structure and civil jobs will be in the scope of the contractor.No. yes 1

125Maint. of light junction box single or 3 phase, grouting on

wall, welding of structure etc if reqd.No. 845

126Erection of panels. Size limited to 2.4 mtr(ht), 1.2 mtr (depth)

and 1000Kg (Wt). Shfting from stores to site, civil jobs and

cutting/ welding jobs in the scope of contractor.

No. 1

127Fabrication and erection of steel structures . Cutting / welding

and all other related jobs in the scope of the contractor

including provision of welding/ cuting sets.

MT 1

128Casting and machining of machine parts like motor end

cover, foot, fan etc. as per sample.Kg

a Cast Iron Kg 100

b Cast Aluminium Kg NO 1

129Erection, testing, commissioning and earthing of light fixture

of any size(supply NFL's scope) on existing pole incl. supply

of GI pipe and bracket(Contractor's scope)

No. NA 1

130

Erection, testing, commissioning and earthing of following

type of Lighting fixtures incl.control gear, regulator etc. (petty

materials as reqd. will be supplied by the contractor) Related

welding and civil jobs will be in the scope of the contractor.

No.

a F/L 2x40 W or 100 Watt bulk head light fitting. No. 125

b Well glass fitting upto 200W of any type No. 31

c Light fittings of any type upto 2x400 Watt No. 119

d Ceiling fan/Ex. fan of any size. No. 1

e Flameproof light fitting 125W. No. 1

fSupply and installation of protective guard (wire mesh) for

light fittings up to 400W of any type.No. 1

131Transportation of materials from plant to plant, within plant,

plant to workshop, stores to plant/workshop, workshop to

t/ship or within t/ship.

No. NA

a Below 20 Kg No. 1767

b Above 20 Kg up to 50 Kg No. 1562

c Above 50 Kg but below 100 Kg No. 1022

d LT motors upto 3.7 KW No. 524

e do above 3.7 KW to 15 KW No. NO 311

f Shifting of 200 Ltrs. oil drums No. yes 93

g Shifting of Grease gun bucket No. NA 838

132Pulling of cable over the cable tray in trench or pipe to bring

out margin at the end for its re-termination.No. yes

aPulling up to length of 50 mtr for cable sizes upto 3/3.5x70

sq.mm.No. NA 182

b --do-- but 150 mtr size -do- No. NA 85

Page 11: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

cPulling upto length of 50 mtr of cable size upto 3/3.5x95 to

3/3.5x185 sq mm. No. NA 52

d -do- but 150 mtr size -do- NO 69

133

Cleaning of s/stn blower filter in 3.3KV, 11KV, 415V and

PCC rooms including removal of filters, steam washing and

refixing at site. Steam at suitable place will be provided by

NFL.

Manday NO 228

134

Cleaning of battery bank. Topping up with distilled water and

application of petroleum jelly on battery terminals and taking

readings of cell volatge and sp gravity and recording the

same.

Manday NO 349

135 Cleaning of Capacitor banksas per site requirement . Manday NO 251

136Cleaning of panels in substationsas per site

requirementManday NA 1484

137 Cleaning of transformers in s/stns as per site requirement. Manday NO 629

138Cleaning of cable tray of all sizes with water spray and

wire brush etc as per site requirement. Manday 877

139Cleaning of cable trench from including cleaning of cables

with water spray and removing mud from trench and

dewatering of trench etc as per site requirement.

Manday 461

140Cleaning of LT motors of all sizes in plant as per plant

requirement.Manday 946

141Cleaning of duct of pressurisation blower in Sub station as

per site requirement.Manday NA 205

142Cleaning of HT motors of all sizes in plantas per plant

requirement. Manday yes 426

143Cleaning, rinsing shifting of transformer oil drums, pipe

connections with oil filter machine, sampling etc as per site

requirement.

Manday yes 6

144Cutting and cleaning of burnt winding of motors in elect

workshop.Manday NA 278

144 aCleaning of smoke detectors ,pill boxes and panels of Fire

Alarm systemManday 150

145Transportation of sophisticated electronic / electrical testing

equipments from lab to plant and vice-versa. Manday

a Upto 50 Kg. Manday 224

b From 51 Kg to 100 Kg Manday 146

c Above 100 Kg. Manday 63

146Connection or disconnection of welding sets / jet cleaner or

other temporary equipments in plant.Manday 63

147Lubrication of HT/LT motors including all related job like

shifting of tools and tackles.Manday 144

148Making of motor coil sets in electrical workshop as per

instructions of engr-in-charge.Manday 143

149Assistance in execution of intermittent electrical jobs during

short shutdowns / onforeseen breakdowns / Annual turn

around etc.

a1 Unskilled labourer (Normal working time- 8 hrs per day) No. No 1344

a2 Unskilled labourer (oevr time after 8hrs normal duty) Hr No 3584

b1 Welder (Normal working time- 8 hrs per day) No. No 1

b2 Welder (oevr time after 8hrs normal duty) Hr No 1

Page 12: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

c1 Rigger (Normal working time- 8 hrs per day) No. No 1

c2 Rigger (oevr time after 8hrs normal duty) Hr 1

d1 Skilled Electrician (Normal working time- 8 hrs per day) No. 276

d2 Skilled Electrician (oevr time after 8hrs normal duty) Hr 739

e Skilled supervisor No. 1

150a

Earthwork in excavation not exceeding 1.5 Mtr in width or 10

sq mts on plan including dressing of sides and ramming of

bottom lift upto 1.5 Mtr including getting out the excavated

soil and disposal of surplus soil as directed.

Cu Mtr 1

150b

Filling available excavated earth in trenches, plinth, sides of

foundation etc in layers not exceeding 20 cm in depth.

Consolidating each deposited layer upto 50 Mtr and lift upto

1.5 Mtr.

Cu Mtr 1

150c

Cutting Bituminous portion of Road and making good the

same including supply of extra quantities of materials

I.e.aggregate, Moorum screening, red bajri etc and labour

rquired.

Cu Mtr 1

150dDemolishing cement concrete incl disposal of material within

50 Mtr lead.Cu Mtr 1

150eProviding and laying in position cement concrete of specified

grade incl the cost of centring & shuttering - All work upto

plinth level.

Cu Mtr 1

152 a 2 Suitable for 3 core cable (PILCA) size 95 to 185 mm2 1

152 b1 Suitable for 3 core cable (XLPE) size 240 to 300 mm2 No. 1

152 b2 Suitable for 3 core cable (PILCA) size 240 to 300 mm2 No. 1

152c Siutable for cable (XLPE) size 1 X 400 mm2 No. 1

153

Supply of End jointing Suitable for 11Kv (UE) system with

heat shrinkable kits of Raychem make for XLPE/PILCA

cable. Jointer shall be trained and hold valid certificate

from Raychem. Supply of joint as well as all other materials

in the scope of the contractor

No.

153 a1 Suitable for 3 core cable (XLPE) size 95 to 185 mm2 No. 1

153 a2 Suitable for 3 core cable (PILCA) size 95 to 185 mm2 1

153 b1 Suitable for 3 core cable (XLPE)size 240 to 400 mm2 No. 1

153 b2 Suitable for 3 core cable (PILCA) size 240 to 400 mm2 1

153c Suitable for cable size 1 X 400 mm2 No. 1

Page 13: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

154

Supply of Straight through jointing Suitable for 3.3Kv (UE)

system with heat shrinkable kits of Raychem make for

XLPE/PVC cable. Jointer shall be trained and hold valid

certificate from Raychem. Supply of joint as well as all other

materials in the scope of the contractor

No.

154a Suitable for 3 core cable size 95 to 150 mm2 No. 1

154b Suitable for 3 core cable size 185 to 400 mm2 No. 1

155

Supply of End jointing Suitable for 3.3Kv (UE) system with

heat shrinkable kits of Raychem make for XLPE/PVC cable.

Jointer shall be trained and hold valid certificate from

Raychem. Supply of joint as well as all other materials in the

No.

155a Suitable for 3 core cable size from 120 to 240mm2 No. 1

155b Suitable for 3 core cable size from 300 to 400mm2 No. 1

156a

Dressing of already laid LT cable upto size of 11 pair in

PVC pipes/ Cassing -capping.( All material Like PVC

pipe,Cassing-capping ,Saddle, surews, plastic gitti etc.

in the scope of contractor.

Mtr. 0 500

156b

Dressing of already laid Telephone cable upto size of

16mm square in PVC pipes/ Cassing -capping.( All

material Like PVC pipe,Cassing-capping ,Saddle,

surews, plastic gitti etc. in the scope of contractor

Mtr. 0 500

157Replacement of LT Motors of following rating as per

details as in scope of workNo.

157a Motors rating up to 1.1Kw No. 0 5

157b Motors rating above 1.1kw up to 3.7 Kw No. 0 10

157c Motors rating above 3.7kw up to 11 Kw No. 0 5

157d Motors rating above 11kw up to 37 Kw No. 0 5

157e Motors rating above 37kw up to 75 Kw No. 0 5

157f Motors rating above 75kw up to 125 Kw No. 0 5

157g Motors rating above 125kw up to 160 Kw No. 0 5

158Re-aalingment of LT Motors of following rating as per

details as in scope of workNo.

158a Motors rating up to 1.1Kw No. 0 5

158b Motors rating above 1.1kw up to 3.7 Kw No. 0 10

158c Motors rating above 3.7kw up to 11 Kw No. 0 5

158d Motors rating above 11kw up to 37 Kw No. 0 5

158e Motors rating above 37kw up to 75 Kw No. 0 5

158f Motors rating above 75kw up to 125 Kw No. 0 5

158g Motors rating above 125kw up to 160 Kw No. 0 5

159 Trimming / Pruning of tree branches Span 0 150

Grand Total

Overall Discount in %

Note - 1. Parties are required to quote item wise workable rates, however evaluation of bid shall be done on

2.Tendrer may quote overall percentage of discount which shall be applicable on all the Items.

Page 14: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 15: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

SOR

AmountRate

(InWords.)

Page 16: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 17: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 18: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 19: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 20: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 21: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 22: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 23: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 24: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 25: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 26: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply
Page 27: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply

Grand Total

Overall Discount in %

Note - 1. Parties are required to quote item wise workable rates, however evaluation of bid shall be done on

2.Tendrer may quote overall percentage of discount which shall be applicable on all the Items.

Page 28: SOR - nationalfertilizers.com · SOR Item No. DESCRIPTION OF ITEMS Unit Estimated ... Transformer bushing, isolator in 132 kV switch yard. ... sets yes 2 80a Erection of poles (Supply