SOLUTIONS OR ATA CENTERS Flyer za...Title: Flyer Catalog: SOLUTIONS FOR DATA CENTERS Author: HIOKI...

2
4 1 SOLUTIONS FOR DATA CENTERS LR8400: Temperature LR8400: Voltage PW3360: Instantaneous voltage PW3360: Instantaneous current PW3360: Instantaneous power factor Implement Reliable Maintenance Programs with Efficient Measurement Data Management EARTH TESTER FT6031 6 Server Rooms Substations In-house Generator Storage Batteries UPS 5G Antennas Electrical Panels Electrical Panels HVAC BATTERY TESTER BT3554 2 CLAMP ON POWER LOGGER PW3365 3 MEMORY HiLOGGER LR8450 4 CLAMP METER INSULATION TESTER DIGITAL MULTIMETER ※ GENNECT not supported 5 POWER QUALITY ANALYZER PQ3198 1 3 MEMORY HiCORDER MR6000 1 GENNECT Cross Send data wirelessly to your mobile device to easily manage data on site GENNECT One Transfer data to your PC via LAN to get a complete picture of all measured signals HUB Power quality Power consumption Temperature & humidity List or graph data in real-time • Verify current waveforms or place data labels right on the site photo • Use recorded data to make PDF reports Bluetooth ® 2 Diagnose Condition of Emergency Batteries Record & Analyze POWER ISSUES 1 Record sudden issues that can't be captured by the SNMP Identify POWER CONSUMPTION 3 Regular Inspections of ELECTRICAL PANELS 5 6 Ground Resistance INSPECTION Temperature/ Humidity Control SERVER ROOMS 4 Thermal Management of 5G Antennas 4 4 5 1 3 1 1 Grounding Rod 6 2 1

Transcript of SOLUTIONS OR ATA CENTERS Flyer za...Title: Flyer Catalog: SOLUTIONS FOR DATA CENTERS Author: HIOKI...

Page 1: SOLUTIONS OR ATA CENTERS Flyer za...Title: Flyer Catalog: SOLUTIONS FOR DATA CENTERS Author: HIOKI Subject: Maintain the Integrity of Your Mission-Critical Equipment Keywords: PQ3198,MR6000,BT3554,PW3365-20,LR8450,FT6031

Maintain the Integrity of Your Mission-Critical Equipment

4

1

SOLUTIONS FOR DATA CENTERS

LR8400: Temperature

LR8400: Voltage

PW3360: Instantaneous voltage

PW3360: Instantaneous current

PW3360: Instantaneous power factor

Implement Reliable Maintenance Programs with Efficient Measurement Data Management

EARTHTESTERFT6031

6

Server Rooms

Substations

In-house Generator

Storage Batteries

UPS

5G Antennas

Electrical Panels

Electrical Panels

HVAC

BATTERYTESTERBT3554

2

CLAMP ONPOWER LOGGERPW3365

3

MEMORYHiLOGGERLR8450

4

CLAMP METERINSULATION TESTERDIGITAL MULTIMETER

※ GENNECT not supported

5

POWER QUALITY ANALYZERPQ3198

1 3

MEMORY HiCORDERMR6000

1

GENNECT CrossSend data wirelessly to your mobile device to easilymanage data on site

GENNECT OneTransfer data to your PC via LAN to get a completepicture of all measured signals

HUB

Powerquality

Powerconsumption

Temperature& humidity List or graph data in real-time

• Verify current waveforms or place data labels right on the site photo• Use recorded data to make PDF reportsBluetooth®

2Diagnose Condition of

EmergencyBatteries

Record & AnalyzePOWER ISSUES

1

Record sudden issuesthat can't be captured

by the SNMP

IdentifyPOWER

CONSUMPTION

3

Regular Inspections ofELECTRICAL

PANELS

5

6Ground Resistance

INSPECTION

Temperature/Humidity Control

SERVER ROOMS

4Thermal

Management of5G Antennas

4

451

3

1

1

Grounding Rod

6

21

Page 2: SOLUTIONS OR ATA CENTERS Flyer za...Title: Flyer Catalog: SOLUTIONS FOR DATA CENTERS Author: HIOKI Subject: Maintain the Integrity of Your Mission-Critical Equipment Keywords: PQ3198,MR6000,BT3554,PW3365-20,LR8450,FT6031

HEADQUARTERS 81 Koizumi, Ueda, Nagano 386-1192 Japan

https://www.hioki.com/

All information correct as of Feb. 13, 2020. All specifications are subject to change without notice. Flyer_Data_Center_E2-02M

DISTRIBUTED BY

Note: Company names and product names appearing in this catalog are trademarks or registered trademarks of various companies.

Record sudden problems missed by the SNMP*

Receiving Equipment UPS

PQ3198IEC 61000-4-30Class A PQA

Inrush Current

Transients

Equipment Damage and Malfunction Due to Power QualityClarify trouble spots via simultaneous recording of 3 systems

UPS

Main

Sub

Switch Server

MR60008966 x 5

U8977 x 3

Reliable Preventive Maintenance of UPSDiagnose deterioration of lead-acid batteries (also measure lithium-ion batteries)

Reach deep within battery racksL2020 test lead with L-shaped tip

BT3554

Distribution panelAC power InverterConverter

Battery

Harmonicnoise

Measure correctly even in noisy environmentsAddress inverter noise emitting from UPS

Measure mixed AC & DC signals

Founded in 1935, Hioki has grown to become a world leader in providing consistent delivery of test and measuring instruments. By integrating both R&D and manufacturing in a central facility, we succeed in implementing a fully sustainable end-to-end product innovation life cycle to deliver instru-ments characterized by precision, safety and quality to customers around the world.

JAPANNAGANO UEDA City

85 years ofmeasurement

expertise

Thin jaw tackles complicated wiring with easeAC/DC CLAMP METER CM4376

Innovativethin design Traditional jaw

*SNMP: Simple Network Management Protocol : a protocol used to monitor the live and operational status of IP devices - widely used for measuring rack temperature and current

Centrally manage data from allLAN-connected instruments with a PC

Connect toGENNECT One

1

23