1
DANAHER Platforms
Outstanding portfolio of market-leading brands
Diagnostics
Life Sciences & DiagnosticsLife Sciences & Diagnostics
Test & Measurement
Test & MeasurementEnvironmentalEnvironmental
Communications
Water Quality
Gilbarco Veeder-Root
Instruments
Life Sciences
DentalDental
Dental
Industrial Technologies
Industrial Technologies
Product ID
Automation & DSC
3
Started: 1876Acquired: 1998
Applications:
Liquid Temperature
Winding Temperature
Liquid Level Indication
Gas Density Monitor (SF6)
Started: 1945
Applications:
Pressure Relief
Pressure Monitoring
Liquid Temperature
Winding Temperature
Liquid Level Indication
Flow Indication
Vacuum / Bleeder Valve
Electronic Transformer Monitor
Fiber Optic Winding Temperature
Dissolved Gas Analysis (DGA)
Started: 1980Acquired: 2002
Applications:
Digital Fault Recording
Traveling Wave Fault Location
Sequence of Events Recorders
Alarm Annunciation
Breaker Condition Monitoring
Started: 1982Acquired: 2005
Applications:
BEN Digital Fault Recorders
Power Quality Monitors
Phases Measurementunit
BENStarted: 1994Acquired: 2010
Applications:
Generator / Motor Partial Discharge Monitoring
Started: 2004Acquired: 2010
Applications:
T/Guard™: Affordable systemfor temperature monitoring
T/Guard2™: Full-featured system for temperature monitoring
Omniflex: Designed for heat-run tests and lab applications
Nomad™: Ideal for probe testing by OEM’s
T/Guard Link™: Designed for OEM integration
Started: 1994Acquired: 2009
Applications:
GIS Partial Discharge Monitoring
Transformer Partial Discharge Monitoring
Bushing Tan Delta Capacitance
Cable PD
Started: 2001Acquired: 2013
Applications:
Transformer Dissolve Gas Analysis
1945 1986 1998 2002 2005 2009 2010 2010 2013
Founded (USA)
Acquisition Sweden UK Belgium UK Canada Canada USA
Solution Overview
4
14
Transformers CBM
Transformers Condition Based Monitoring
Sensors - Transformers
15
Monitors - Transformers
16
Direct Winding Temperature Monitor
17
Transformer Breathers
18
Conservator Tank
Main Tank
LTC
Transformer Oil & Solid Insulation
A product line designed to keep transformers containing a conservator tank and/or a Load Tap Changer DRY.
transformers containing RY.
• Silica gel regenerated.
• Does not requireadditional maintenance bythe user.
Intelligent Transformer Monitor
1919
Oil Temperature : e.g. AKM345 GEN2Oil Level Indicator
Direct Winding temperature via Fibre
Direct Winding Simulation: e.g. AKM345 DW
Ambient Temperature
TransLife / Fan Bank Control / Event Recorder
Smart Transformer Breather
Pressure Relief Device
Rapid pressure rise relay
Partial Discharge Monitor
20
Monitored parameter -Ultra High Frequency -Range 500MHz~1500MHz
Partial Discharge Monitor
21
Type of Defects in transformers
1.
2.
1. Discharge in Coil winding2. Corona discharges on sharp
edges (ground or HV)3. Void discharges from
bushings4. Floating parts (not proper
connected to HV or ground)5. Void discharges in solid
insulation material 6. Surface discharges (on
insulating material)
3.
4.5.
6.
Transformer Bushing Monitor
22
Data Acquisition
UnitSoftware
Reference Voltage (VT):
Bushing
Temperature measurement
Monitoring Unit:• Data handling/ processing• 61850/ SCADA integration• Data display• Expert System• Data storage
Data Acquisition Unit:• 6 Bushing channels• 6 Reference channels• 6 temperature channels• Filtering/ de-noising• digitalisation
Bushing Monitor for 6 bushings
Bushing Tap Adapter
Monitored parameter -Capacitance -Tan Delta
Typical bushing defects
23
Insulation ageing- Oil
- paper
Moisture Voids/ Delamination’s
Surface discharges (no
real defect)Contact
problems
Partial breakdowns (short circuit between
layers)
Surface contamination
Type of Defects in bushing
Transformer DGA Monitor
24
Gas Chromatography(GC) –is the only method approved by IEEE / IEC standards, though other methods do exist.
Transformer DGA Monitor
25
TM8™
TM3 ™ TM1 ™
What is QTMS?
Highly configurable and easily field upgradable monitor for transformers and related assets
QTMS
LPRD XPRD
RPRR
Pressure Temperature
104 / AKM345
Level / Flow
Liquid Level
Flow Gauges
SmartSub
Smart BreatherDissolved Gas Analysis
Multi-Gas
Single Gas
Direct Winding FO
1 & 2 kg 4 kg
Sensor Data
Polar and Offshore
Partial Discharge Additional Monitoring
609OCU
Web Interface
Bushing
LTC Monitoring
Geomagnetically Induced Current
Qualitrol Solution- QTMS
26
What is QTMS?
Bushing Monitor
• Real time monitoring of bushing health
• Detect early changes in Tan Delta• Detect early changes in capacitance
Relays
• Versatile control of cooling systems, alarms, and trip signals• 8 relays per module
• Up to 112 relays available per system
Rapid Pressure Rise Relay
• Help prevent catastrophic damage due to sudden pressure increases
• Trip function to avoid further damage due to potential fault occurrence
* not represented in the image
Fiber Optics
• Accurate direct winding temperature• Accurately characterize asset aging
• Available in 4, 6, or 8 inputs
CPU
• USB and serial port connections; IEC61850, DNP 3.0, Modbus,
IEC60870• Web based interface
• Universal power supply
Digital Inputs
• Completely configurable per specification with wiring on front panel
• 14 digital inputs per module• Up to 196 digital inputs per system
Modular approach for ease in customization, configuration, and field upgradable
1
2
4 5
7
2
3
4
56
6
Analog Inputs
• Accepts a variety of analog input types with flexible configuration
• 8 analog inputs per module• Up to 112 analog inputs per system
Display
• Optional push button display screen• Large backlit LCD screen • Integrated overlay buttons
8
8 7
1
Qualitrol Solution- QTMS
Station level view: Line diagram showing assets
Component level view: Showing all displays, data trends and other analysis for each parameter
Intelligent Visualization
SmartSUB: Easy to use HMI
Country wide view: Showing all substations
Asset Level View
Qualitrol Solution- SmartSub
28
http://www.qualitrolcorp.com
29
Thank You
30