SOLUTION DATA SHEET SINGLEMODE … Data Sheets...SINGLEMODE ENTERPRISE FIBER | OS2...

2
Together, we offer the strongest selection of LAN and data center network infrastructure solutions in the industry. SINGLEMODE ENTERPRISE FIBER | OS2 BerkTekLevitonTechnologies.com Take fiber closer to the work area using a telecommunications enclosure Broad selection of enclosures to address any density requirements Large campuses benefit from Adventum cable with singlemode fiber distances greater than one kilometer Adventum ® Indoor/Outdoor Backbone Cable Premises Distribution Indoor Backbone Cable Copper Horizontal Cable SOLUTION DATA SHEET SINGLEMODE ENTERPRISE FIBER | OS2 Significantly exceeds ANSI/TIA-568-C.3 standards Recommended for campus and building backbones, entrance facilities, equipment rooms and long distance networks Limited lifetime warranty available when projects are installed by Leviton or Berk-Tek certified contractors INTER-BUILDING AND INTRA-BUILDING APPLICATIONS Our systems ensure optimum performance throughout the entire network, with cabling and connectivity options that address your unique requirements for application speed, distance, and cabling pathways. See below for an example of how our solutions can support your entire facility. For traditional network architectures, take fiber to the TR and use copper cable in the horizontal Wall-mount enclosure to transition from outside plant cable to inside plant cable

Transcript of SOLUTION DATA SHEET SINGLEMODE … Data Sheets...SINGLEMODE ENTERPRISE FIBER | OS2...

Together we offer the strongest selection of LAN and data center network infrastructure solutions in the industry

SINGLEMODE ENTERPRISE FIBER | OS2 BerkTekLevitonTechnologiescom

Take fiber closer to the work area using a telecommunications enclosure

Broad selection of enclosures to address any density requirements

Large campuses benefit from Adventum cable with singlemode fiber distances greater than one kilometer

Adventumreg IndoorOutdoor Backbone Cable

Premises Distribution Indoor Backbone Cable

Copper Horizontal Cable

SOLUTION DATA SHEET

SINGLEMODE ENTERPRISE FIBER | OS2bullSignificantly exceeds ANSITIA-568-C3 standards

bullRecommended for campus and building backbones entrance facilities equipment rooms and long distance networks

bull Limited lifetime warranty available when projects are installed by Leviton or Berk-Tek certified contractors

INTER-BUILDING AND INTRA-BUILDING APPLICATIONS Our systems ensure optimum performance throughout the entire network with cabling and connectivity options that address your unique requirements for application speed distance and cabling pathways See below for an example of how our solutions can support your entire facility

For traditional network architectures take fiber to the TR and use copper cable in the horizontal

Wall-mount enclosure to transition from outside plant cable to inside plant cable

SINGLEMODE ENTERPRISE FIBER | OS2 BerkTekLevitonTechnologiescom

Rele

ased

May

201

3 E1

3 44

55C

LEVITON PATCH CORDS FIBER OPTIC PATCH CORDSbull Riser-ratedsimplexorduplexzip-cordmultimodecablebull lt04dBinsertionlossgt25dBbackreflectionbull AdditionalpatchcordsavailableasMake-To-Order

PART NUMBERS LC-LC SC-SC

SMUPC (OS2) Duplex UPDLC-Sxx UPDSC-Sxx

SMAPC (OS2) Simplex Make-to-Order APSSC-Sxx

xx = Length in meters (01) (02) (03) (05) (10) = For assistance customizing your harnesses please visit levtioncomconfigurator or call Tech Support at 8008243005

LEVITON FIELD INSTALLABLE CONNECTORSFASTCAMreg FIBER OPTIC PRE-POLISHED CONNECTORS bull Requirenohandpolishingterminateinlessthanaminutebull Noproprietarytoolorfixturerequiredbull Re-terminateuptothreetimesFAST-CUREreg FIBER OPTIC ANAEROBIC CONNECTORSbull NoheatovenorepoxycuringterminateinlessthanthreeminutesbullMostrobustconnectionidealforinsideandoutside

plant applications

PART NUMBERS LC SC

SMUPC FastCAM 49991-SLC 49991-SSC

SMUPC Fast-Cure 49990-SDL 49990-SSC

SPECIFICATIONSSINGLE-MODE SYSTEM (OS2)

OS2

10G 1G

AB

DISTANCE (METERS)BANDWIDTH2000 4000 6000 8000 10000

BERK-TEKFIBERCODE

BERK-TEK CABLEbull Industry-leadingfibercountswithupto432fiberAdventumreg

bull Armor-TekTM interlocking armor provides significantly greater strength and durability

bull Widerangeofopticalcableconstructionsavailabletosuitspecific application environments in plenum riser and LSZH flame ratings

bull AllfiberscomplianttoOS2bull Hybridcable(SMMM)optionsavailablebull TL9000CertifiedManufacturingfacilities

BERK-TEK CABLE AVAILABLE FIBER COUNTS

CABLE TYPE

APPLICATION ENVIRONMENT

ARMORING AVAILABLE

Premises Distribution Plenum (PDP) 6-144 Tight

Buffer IndoorArmor-Tek Interlocking Aluminum

Premises Distribution Riser (PDR) 6-144 Tight

Buffer IndoorArmor-Tek Interlocking Aluminum

Adventum Plenum (LTP) 6-432 Loose

Tube IndoorOutdoorArmor-Tek Interlocking Aluminum

Adventum Riser (LTR) 6-432 Loose

Tube IndoorOutdoorArmor-Tek Interlocking Aluminum

Find complete Berk-Tek Fiber Optic Cable information at berktekcom

LEVITON ENCLOSURES AND ADAPTER PLATESOPT-Xreg 1000I 1RU2RU3RU4RU FIBER OPTIC ENCLOSURESbull Slidingtrayremoves(1RU2RU)foreasyfieldterminations

and splicingbull Multipleconfigurationsforyourdensityrequirementsbull Accept Opt-X adapter plates Opt-X MTPreg cassettes and splice trays

PART NUMBERS

Rack-Mount 1RU empty accepts 3 adapter plates 5R1UM-F03

Rack-Mount 1RU empty with sliding tray accepts 3 adapter plates 5R1UM-S03

Rack-Mount 2RU empty accepts 6 adapter plates 5R2UM-F06

Rack-Mount 2RU empty with sliding tray accepts 6 adapter plates 5R2UM-S06

Rack-Mount 3RU empty accepts 9 adapter plates 5R3UM-F09

Rack-Mount 3RU empty accepts 12 adapter plates 5R3UM-F12

Rack-Mount 4RU empty accepts 12 adapter plates 5R4UM-F12

Rack-Mount 4RU empty accepts 15 adapter plates 5R4UM-F15

Wall-Mount small empty solid metal door no lock accepts 2 plates 5W110-00N

Wall-Mount medium empty solid metal door no lock accepts 4 plates 5W310-00N

Leviton offers enclosures in a wide range of styles sizes and configurations with an extensive selection of adapter plates to fit each

OPT-X ADAPTER PLATESbull Exclusivedesignworkswithall

Opt-X enclosuresbull Upto15Opt-Xplates(evenquadLCs)canbeused

in a 4RU enclosurebull Pushpullfastenersallowfortool-freeinstallationbull Availablein6-to24-fiberoptions

PART NUMBERS LC SC

Plate (blue) Duplex SM 6-fiber zirconia ceramic sleeve 5F100-6LC

Plate (blue) Duplex SM 12-fiber zirconica ceramic sleeve 5F100-2LL 5F100-2LC

Plate (blue) Quad SM 24-fiber blue zirconia ceramic sleeve 5F100-4LL

Berk-Tek Fiber Code refers to GIGAlite fiber performance designation in cable part number

Common part numbers and cable types shown

ADDITIONAL OPTIONS AVAILABLE ONLINE

SINGLEMODE ENTERPRISE FIBER | OS2 BerkTekLevitonTechnologiescom

Rele

ased

May

201

3 E1

3 44

55C

LEVITON PATCH CORDS FIBER OPTIC PATCH CORDSbull Riser-ratedsimplexorduplexzip-cordmultimodecablebull lt04dBinsertionlossgt25dBbackreflectionbull AdditionalpatchcordsavailableasMake-To-Order

PART NUMBERS LC-LC SC-SC

SMUPC (OS2) Duplex UPDLC-Sxx UPDSC-Sxx

SMAPC (OS2) Simplex Make-to-Order APSSC-Sxx

xx = Length in meters (01) (02) (03) (05) (10) = For assistance customizing your harnesses please visit levtioncomconfigurator or call Tech Support at 8008243005

LEVITON FIELD INSTALLABLE CONNECTORSFASTCAMreg FIBER OPTIC PRE-POLISHED CONNECTORS bull Requirenohandpolishingterminateinlessthanaminutebull Noproprietarytoolorfixturerequiredbull Re-terminateuptothreetimesFAST-CUREreg FIBER OPTIC ANAEROBIC CONNECTORSbull NoheatovenorepoxycuringterminateinlessthanthreeminutesbullMostrobustconnectionidealforinsideandoutside

plant applications

PART NUMBERS LC SC

SMUPC FastCAM 49991-SLC 49991-SSC

SMUPC Fast-Cure 49990-SDL 49990-SSC

SPECIFICATIONSSINGLE-MODE SYSTEM (OS2)

OS2

10G 1G

AB

DISTANCE (METERS)BANDWIDTH2000 4000 6000 8000 10000

BERK-TEKFIBERCODE

BERK-TEK CABLEbull Industry-leadingfibercountswithupto432fiberAdventumreg

bull Armor-TekTM interlocking armor provides significantly greater strength and durability

bull Widerangeofopticalcableconstructionsavailabletosuitspecific application environments in plenum riser and LSZH flame ratings

bull AllfiberscomplianttoOS2bull Hybridcable(SMMM)optionsavailablebull TL9000CertifiedManufacturingfacilities

BERK-TEK CABLE AVAILABLE FIBER COUNTS

CABLE TYPE

APPLICATION ENVIRONMENT

ARMORING AVAILABLE

Premises Distribution Plenum (PDP) 6-144 Tight

Buffer IndoorArmor-Tek Interlocking Aluminum

Premises Distribution Riser (PDR) 6-144 Tight

Buffer IndoorArmor-Tek Interlocking Aluminum

Adventum Plenum (LTP) 6-432 Loose

Tube IndoorOutdoorArmor-Tek Interlocking Aluminum

Adventum Riser (LTR) 6-432 Loose

Tube IndoorOutdoorArmor-Tek Interlocking Aluminum

Find complete Berk-Tek Fiber Optic Cable information at berktekcom

LEVITON ENCLOSURES AND ADAPTER PLATESOPT-Xreg 1000I 1RU2RU3RU4RU FIBER OPTIC ENCLOSURESbull Slidingtrayremoves(1RU2RU)foreasyfieldterminations

and splicingbull Multipleconfigurationsforyourdensityrequirementsbull Accept Opt-X adapter plates Opt-X MTPreg cassettes and splice trays

PART NUMBERS

Rack-Mount 1RU empty accepts 3 adapter plates 5R1UM-F03

Rack-Mount 1RU empty with sliding tray accepts 3 adapter plates 5R1UM-S03

Rack-Mount 2RU empty accepts 6 adapter plates 5R2UM-F06

Rack-Mount 2RU empty with sliding tray accepts 6 adapter plates 5R2UM-S06

Rack-Mount 3RU empty accepts 9 adapter plates 5R3UM-F09

Rack-Mount 3RU empty accepts 12 adapter plates 5R3UM-F12

Rack-Mount 4RU empty accepts 12 adapter plates 5R4UM-F12

Rack-Mount 4RU empty accepts 15 adapter plates 5R4UM-F15

Wall-Mount small empty solid metal door no lock accepts 2 plates 5W110-00N

Wall-Mount medium empty solid metal door no lock accepts 4 plates 5W310-00N

Leviton offers enclosures in a wide range of styles sizes and configurations with an extensive selection of adapter plates to fit each

OPT-X ADAPTER PLATESbull Exclusivedesignworkswithall

Opt-X enclosuresbull Upto15Opt-Xplates(evenquadLCs)canbeused

in a 4RU enclosurebull Pushpullfastenersallowfortool-freeinstallationbull Availablein6-to24-fiberoptions

PART NUMBERS LC SC

Plate (blue) Duplex SM 6-fiber zirconia ceramic sleeve 5F100-6LC

Plate (blue) Duplex SM 12-fiber zirconica ceramic sleeve 5F100-2LL 5F100-2LC

Plate (blue) Quad SM 24-fiber blue zirconia ceramic sleeve 5F100-4LL

Berk-Tek Fiber Code refers to GIGAlite fiber performance designation in cable part number

Common part numbers and cable types shown

ADDITIONAL OPTIONS AVAILABLE ONLINE