SOLUCIONES CAD-CAM INTRAORALes.dynamicabutment.com/wp-content/uploads/sites/3/... · EB External...
Transcript of SOLUCIONES CAD-CAM INTRAORALes.dynamicabutment.com/wp-content/uploads/sites/3/... · EB External...
SOLUCIONES
CAD-CAM INTRAORAL
scan
5 LISTA DE COMPATIBILIDADES SISTEMA INTRAORAL
6 INVESTIGACIÓN & DESARROLLO
7 QUALITY CENTER & SERVICIO DE ATENCIÓN AL CLIENTE
8 SISTEMA DINÁMICO PARA ESTRUCTURAS FRESADAS
10 SISTEMA INTRAORAL
12 SCANBODY INTRAORAL
13 ADAPTADOR
14 RÉPLICA DIGITAL
16 DYNAMIC MILLING TOOL
18 INTERFASE DINÁMICA® 3.0
20 CILINDROS PRE-FRESADOS
22 SOFTWARE CAD-CAM
24 CAD-CAM DIRECTO A IMPLANTE
26 CAD-CAM INTERFASE DINÁMICA® 3.0
27 CAD-CAM RÉPLICA DIGITAL
27 CAD CILINDROS PRE-FRESADO
28 COLORES SISTEMA INTRAORAL SEGÚN COMPATIBILIDAD
29 TIPO DE SCANBODY SEGÚN COMPATIBILIDAD
30 TORNILLOS DINÁMICOS Y DESTORNILLADOR DINÁMICO & TORNILLOS
RECTOS Y DESTORNILLADORES
31 DESTORNILLADOR SISTEMA INTRAORAL & COMPLEMENTOS
32 DYNAMIC MILLING TOOL
34 TORNILLOS DINÁMICOS - ESPECIFICACIONES TÉCNICAS
36 TORNILLOS RECTOS - ESPECIFICACIONES TÉCNICAS
38 COMPATIBILIDADES SISTEMA INTRAORAL
146 GARANTÍA TALLADIUM
ÍNDICE
Aprobación, mediante organismo notificado, del aseguramiento del sistema de calidad total según normativa comunitaria, para productos sanitarios de clase I.Clase I incluye: Scanbody Intraoral, Adaptador Scanbody Intraoral, Réplica Digital y destornillador Sistema Intraoral.
0051
Encuentre todas las compatibilidades de nuestros productos en nuestra tienda online (Solo España):
www.dynamicabutmentstore.es
DYNAMIC ABUTMENT® SOLUTIONS AV. BLONDEL, 54 3º · 25002 · LLEIDA (SPAIN)TEL. +34 973 289 [email protected] Abutment® Solutions es la marca comercial del fabricante Talladium España S.L
Todas las marcas y nombres comerciales citados en este catálogo están registradas por sus respectivas firmas. Las imágenes que aparecen son orientativas. Todas las referencias y textos de este catálogo son válidos salvo error tipográfico.Talladium España s.l se reserva el derecho de modificar este documento sin previo aviso.Talladium España s.l no se hace responsable del buen funcionamiento de sus productos si no se contemplan las indicaciones correspondientes a cada referencia.La información que se muestra en este catálogo está dirigida exclusivamente al profesional del sector dental.
5 DYNAMIC ABUTMENT® SOLUTIONS
AB, 38 I2I22I5I55I10I15
ACE, 40 Hexágono ExternoInfinity TRI-CAMInfinity Hexágono Interno ADIN, 42 SwellTouareg-S/Touareg-OSTouareg Closefit ALPHABIO, 44 SPIICEDFIATID ANCLADEN, 46 Anclalock ANTHOGYR, 46 Anthofit HEOssfit
ARDS, 48 SmartClassicPremium
ASTRA,50 AquaLilac
AVINENT,52 HEHITransepitelial
BIOGENESIS, 543IconAticonIticon BIOHORIZON, 56Tapered InternoInterno BIOMET 3I, 58 OsseotiteCertainLow Profile
BIOLOK, 60 Hexágono Externo
BIONER, 62 Ikelt / BikeltHikeltTopDMTransepitelial A-5M
BIOTEC, 64 SPR/CIMSPR/SPTT/CIM
BTI, 64 Conexión Externa BTK, 66 Klassic/Konic
B&W, 66Hexágono Externo
CONEXÃO SISTEMA DE PRÓTESE, 68 FlashTorqExpand
CORTEX, 70 DynamixClassixSaturnPlataforma Cónica
DENTALTECH, 70 Implogic
DENTIS, 72 s-Clean
DENTIUM, 74Simpleline IISuperLine&Implantium
DIO IMPLANTS, 76 UF IIExterno DSP BIOMEDICAL, 78 Hexágono Externo
ECKERMAN, 78Hexágono ELITE MEDICAL, 78 Conexión Externa
EUROTEKNIKA, 80 NaturactisUnevaUneva (Platform Switching)NateaAestheticaNaturall
GALIMPLANT, 86Conexión ExternaConexión Interna
GMI (ILERIMPLANT),86 Phoenix
GT MEDICAL,88Best Fit Octógono InternoBest Fit Hexágono InternoBest Fit Hexágono Externo
HI-TECH, 90 Tapered Self ThreadLogic Plus
IHDE DENTAL (IMBIODENT), 92 Bone Level Plus IMPLANT DIRECT, 94 Replus/Replant/ReactiveLegacySwishplant/SwishplusSwishActiveInteractive
JDENTALCARE, 98 JDEvolution/JDEvolution Plus
KEYSTONE, 98 Restore KLOCKNER,100 KL
LEADER, 100 Tixos Hexágono InternoTixos Hexágono Externo MEGAGEN, 102 AnyOne InternoAnyOne Externo MICRODENT, 104 Universal
MIS, 106 LanceSevenM4 MOZO GRAU, 108 MG OsseousMG Inhex
MPI, 110 Conexión Externa HEConexión Interna CM
NEOBIOTECH, 112 EB External SystemIS Implant System
NEODENT, 114 Cono Morse Mini PilarSmart HE
NOBEL BIOCARE, 116 BranemarkMulti-UnitReplaceActive
NORMON, 120 Normonimplant HENormonimplant HI
OSSEOLIFE (ZIACOM), 120OEX OSSTEM IMPLANT, 122 TSUS OSTEOPLUS, 124 SheShi
PHIBO, 124 TSH/BNT Serie 3TSH/BNT Serie 4
PROCLINIC, 126 Cilindro Externo/Cónico ExternoCilindro Interno/Cónico InternoSP Octa RADHEX, 128 PHE
SGS, 128 P1P7
SIGNO VINCES, 130DuoInttegraCompactDuocon SOUTHERN IMPLANTS, 132 Tri-NexIT ConnectionHexágono ExternoDeep ConicalHexágono InternoCompact Conical STRAUMANN, 136 Octógono InternoOctógono ExternoBone Level
SYBRON IMPLANTSSOLUTIONS, 138 Endopore (Innova)
TITANIUM-FIX, 138 b-fix TRI DENTAL IMPLANTS, 140 TRI-Vent TRINON, 140 Q2QK
VULKAN IMPLANTS, 142 IN-Hex ZIMMER, 144 Screw-VentSwiss-Plus
Lista de compatibilidades SISTEMA INTRAORAL
Sistema Intraoral
Investigación & DesarrolloSiempre dispuestos a ir un paso por delante La investigación e innovación en soluciones protésicas son el sello distintivo que mantiene a Dynamic Abutment Solutions® como el referente en sistemas angulados.La proximidad a las necesidades de los profesionales y la filosofía innovadora de la marca permiten a nuestro equipo técnico estar a la vanguardia del sector en el desarrollo de producto, desarrollo en el que priman a su vez las máximas prestaciones que aporta el producto, la facilidad de uso en cada trabajo y la mejora del resultado estético.
Desde sus inicios, la investigación y el desarrollo de nuevos productos han sido un eje básico en nuestros objetivos que nos ha permitido generar proyectos innovadores que responden a las necesidades del sector.
El resultado, concretado en numerosas patentes presentadas por nuestro Departamento de I+D+i, se ha traducido en nuevos lanzamientos de productos en el mercado fruto del trabajo de nuestro departamento de I+D+i y de la colaboración con los mejores profesionales y empresas líderes que, como Dynamic Abutment Solutions, apuestan por la investigación y desarrollo.
Dynamic Abutment Solutions siempre estamos dispuestos a dar un paso adelante. Por eso hemos puesto en marcha el Production Center: un centro de producción propio que nos permite el prototipado rápido de nuevos productos y el estudio aplicado de nuevas tecnologías.
El Centro de I+D+i, certificado según norma UNE-166002, puede asegurar un control exhaustivo del 100% en todas las fases de desarrollo de nuevos proyectos. Permitiendo que los mismos se traduzcan en nuevos productos de los que puedan beneficiarse nuestros clientes lo antes posible con los máximos niveles de seguridad y calidad, tal y como siempre se han caracterizado nuestros productos.
6 Medical devices
Quality Management System
El centro de calidad dispone de una sala
blanca ISO-8
Quality Center Servicio de atención al clienteEl centro exclusivo de Atención al Cliente de Dynamic Abutment® Solutions tiene como objetivo principal establecer una comunicación constante con nuestros clientes y colaboradores.
Por otra parte, ofrecemos respuestas y soluciones instantáneas a sus preguntas con asesoramiento y soporte directo del departamento técnico de I+D+i para los casos más complejos.
El contacto directo y las sugerencias de nuestros clientes nos permiten mejorar continuamente la calidad de los productos y servicios que ofrecemos diariamente.
Dynamic Abutment® Solutions destina importantes recursos en asegurar que el producto que reciben nuestros clientes se entrega con las máximas garantías de calidad y seguridad. Dotado con los últimos equipos de marcado, control y medida, así como del equipamiento específico para efectuar tratamientos físico - químicos en nuestros productos.
Nuestra presencia en los mercados internacionales implica disponer de las preceptivas certificaciones sanitarias que amparen a nuestro producto sanitario: marcado CE, normativa CMD/CAS o certificaciones FDA.
La garantía de que los dispositivos puestos en el mercado al alcance de nuestros clientes están acordes con la reglamentación sanitaria supone uno de nuestros mayores compromisos.Desde nuestros inicios, la calidad y seguridad de nuestros productos es nuestro principal objetivo: UNE-EN ISO 9001:2015 , UNE-EN ISO 13485:2016, y UNE 166002:2014
Certificado UNE 166002 de Sistemas
de gestión de I+D+i.7 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
8 9 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS8 8
Sistema Dinámicopara estructurasfresadas
Más de 100.000 casos resueltos con el sistema dinámico
Destornillador dinámico
Abarcan todas las métricas de rosca de implante disponibles en el mercado. Se utilizan junto al Pilar Dinámico® 3.0, a la Interfase Dinámica® 3.0 o para estructuras fresadas con canal de orificio de tornillo angulado hasta 30°: por ello disponemos de varias longitudes de cada métrica parafacilitar la adaptación a sus estructuras.
Todos los tornillos se entregan perfectamente identificados con su número de lote y referencia, permiten la correcta trazabilidad y registro de cada tornillo en el carnet para el paciente y en el historial clínico o del laboratorio.Se deben manipular exclusivamente con el destornillador Dinámico 3.0. Todos están fabricados en Titanio grado V.
Tornillos dinámicos
Destornillador con cabeza hexalobular, exclusivo del sistema Pilar Dinámico® 3.0; longitudes: 18 -24 -32mm.Vástago con conexión para contra ángulo para facilitar su uso con carraca dinamométrica o manual mediante los adaptadores o mangos correspondientes.
El conjunto tornillo-destornillador del sistema Pilar Dinámico®3.0 se utiliza en aquellos casos en los que es necesario rectificarla entrada de los tornillos debido a una posición desfavorable delos implantes, mejorando así la funcionalidad y estética de lasestructuras fresadas.
8 9 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
10 DYNAMIC ABUTMENT® SOLUTIONS10 10
El sistema Micro-Scan de Dynamic Abutment® Solutions recoge la última tecnología desarrollada por el departamento de I+D+i para proporcionar la máxima precisión y exactitud en los procesos de escaneado y posterior mecanizado de las restauraciones.Certificamos una precisión mínima
de ±3 µm
Sistema de Scanbody Intraoral de alta precisión para procedimientos de escaneado CAD intraorales o extraorales incorporando el sistema de trabajo angulado
scanSistema Intraoral
Registro digital de la posición del implante mediante un escaner
Producto certificado
Precisoy cómodo de usar
Sistema desujeción único en el mercado
INTERFASE DINÁMICA® 3.0 PRE-MILLED
TornilloRecto
INTRAORALSCANBODY
ADAPTADORRÉPLICA DIGITAL
DIRECTO A IMPLANTE
TornilloDinámico
TornilloDinámico
TornilloRecto
TornilloRecto
DYNAMIC MILLING TOOL
También apto para Escaner de Laboratorio
11
12 13 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS12
3 alturas (10mm, 12mm & 15mm* ) para los casos más complejos de lectura del scanbody
10 scanbodies para más de 200 compatibilidades
ScanbodyIntraoral
Scanbody sin orificiosy sin atornillar
El scanbody no se atornilla al implante, por lo que no tiene orificios en la parte superior dejando el plano Z libre para mejorar el escaneo del cuerpo del scanbody.
* Bajo pedido
++++++Sujeción con imán al adaptador
++++++------ Elemento de conexión y unión
entre el scanbody y el implante.Pieza de distintos colores en función de la compatibilidad.
Destornillador universal especial para el adaptador
Adaptador
1 adaptador para los3 scanbodies de diferente altura
Sujeción con imán al scanbody
al implante dental Enroscado Permite conocer la
posición de las caras del implante
------
12 13 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
14 15 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS14 14
Réplica Digital
Modelo de impresión 3D
Réplica digital de implante dental para simular la posición del implante en un modelo dental impreso en 3D.
Con la utilización de las bilbiotecas CAD se diseña el modelo dental donde se insertarán posteriormente las réplicas.
14 15 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Herramienta de fresado integral de precisión.En el canal angulado de la estructura atornillada directo a implante, se utiliza para fresar el asentamiento del tornillo y para incrementar el diametro interno del canal recto.
Zona de corte
Longitud de trabajo
Dispone de 3 aletas con tres zonas de corte que permiten realizar el fresado del asentamiento del tornillo e incrementar el diametro interno del canal recto.
CorteSuperior
Corte lateral
Corteasentamiento
Cada herramienta es compatible según asentamiento, diámetro y longitud del tornillo.
Dynamic Milling Tool
CorteSuperior
CorteLateralCorte
asentamiento
PASO 2:Corona con canal angulado.
PASO 1:Corona con taladro previo.
PASO 3:Corona con Dynamic Milling Tool.Fresado del asentamiento del tornillo y ampliación del diámetro del canal recto.
TESTEADO y VALIDADO por
16 17 DYNAMIC ABUTMENT® SOLUTIONS
18 19 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Las bases de Titanio de grado 5 tienen un anonizado dorado para mejorar la estética de trabajo
Interfase Dinamica® 3.0‘
*Plataforma estrecha:máxima angulación 25º
*Plataforma regular/ancha máxima angulación 30º
Retenciones exteriores que aseguran un buen agarre
con el cemento
Mecanizado de precisiónde hasta +/- 5 micras
Cajeado lateral que permite la entrada del tornillo y
destornillador Dinámico
Las Interfase Dinámica® 3.0 de Dynamic Abutment® Solutions es una aportación tecnológica al tratamiento digital para la elaboración de sistemas angulados mediante CAD-CAM: el sistema dinámico incluye la Interfase Dinámica®, el conjunto tornillo-destornillador Dinámico, scanbodies y librerías disponibles para los principales softwares CAD del mercado: Exocad, 3Shape, Dentalwings y EGS.
Para corregir el posicionamiento desfavorable del implante hasta 30º
Más de 50.000 casos resueltos con la Interfase Dinámica® 3.0
Corrección de la angulaciónde 0 a 30º
Diseño de la estructura sin angulación.
Diseño de la estructura con 30º de angulación.
Autor: Garbident-Prótesis Dentales
España
18 19 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
20 DYNAMIC ABUTMENT® SOLUTIONS20
Los cilindros con la conexión pre-mecanizada fabricados en Titanio para cementar y en Cromo-cobalto para cargar cerámica, han sido mecanizados con unos ajustes en la conexión de hasta +/-5 micras.
Estos cilindros disponen de una sujeción en la zona posterior con una geometría en V de diseño propio que asegura su posición en máquina con total precisión, unificando así en un único soporte universal todas las conexiones de implantes.
Cilindros Pre-Fresados
Materiales: Titanium Cromo-Cobalto, para
Mecanizado de precisión hasta +/- 5 micras
Un único soporte universal para todos los cilindros
Optimizado para una mejor estrategia de fresado
aplicar cerámica directamente
Este tipo de sujeción protege la conexión del implante durante todo el proceso de fresado al quedar libre de esfuerzos mecánicos.Compatibles con un amplio listado de sistemas de implantes.
Sujeción con geometría en V
Soporte para máquinas CNC con cabezal rotatorio compatible con el sistema EROWA 10x10.
Soporte tipo disco estándar de diámetro de 98mm para posicionar de manera rápida y precisa 3 cilindros con sujeción posterior a la conexión del implante.
Cromo - Cobalto
Titanio grado VISO 5832-3
ISO 5832-12
18
Ø12
Soporte para disco 98mm
Soporte CNC
20 21 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
22 DYNAMIC ABUTMENT® SOLUTIONS22
Software CAD-CAM
La tecnología CAD/CAM representa en estos momentos la apuesta más innovadora en la elaboración de prótesis sobre implante y supone un avance en las restauraciones protésicas convencionales, permitiendo el diseño de rehabilitaciones extremadamente precisas y de mayor calidad.
Directo a Implante
Réplica DigitalInterfase Dinámica® 3.0Cilindro Pre-fresado
Librería Standard
Librería Premium
Con las librerías existen diferentes opciones de trabajo:
22 23 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
24 25 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Directo a implanteCAD
CAM Canal angulado directoa implante validado con los principales Software
CAM del mercado
DynamicMilling Tool
DestonilladorDinámico
TornilloDinámico
LibreríaStandard
CAD
LibreríaPremium
CAD
Para diseñar la parte estética de la prótesis
Para diseñar la parte estética de la prótesis. Con la librería Premium la conexión del implante en CAD es con valores nominales.
Permite fresar los archivos CAD de la conexión del implante
Librería personalizada para cada cliente.Se ajusta la conexión en el CAD para cada cliente hasta validar la conexión.
El cliente fresa con valores nominales.Si es necesario, es posible ajustar la conexión del CAM o la máquina*
La conexión real está validada en el software
CAM
*Fresado directo a implantecon cualquier software CAM24 25 DYNAMIC ABUTMENT® SOLUTIONS
26 27 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS2626
Interfase Dinámica® 3.0
CAD CAM Software CAMTesteados
Cilindro Pre-FresadoCAD
Réplica DigitalCAD - CAM
Model Builder
Model Creator
Model Builder26 27 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
NÚM. CONEXIÓN PLATAFORMA TIPOSCANBODY
REFERENCIAADAPTADOR
PIEZA INTERMEDIA
TORNILLOMAGNÉTICO
1 Nobel Biocare Branemark 4.1 HA 50.313.024.01-2 X2 Zimmer Screw-vent 3.5 HA 50.312.040.01-2
3 Nobel Biocare Active RP HA 50.313.022.01-2
4 Biomet 3I Certain RP HA 50.313.002.01-2
5 Osstem TS RP HA 50.313.030.01-2
6 Zimmer Screw-vent 4.5 HB 50.313.041.01-2
7 Astra Lilac WP HB 50.314.005.01-2
8 Nobel Biocare Branemark NP HC 50.312.023.01-2 X9 Astra Aqua RP HC 50.313.004.01-2
10 Nobel Biocare Active NP HC 50.312.021.01-2
11 Biomet 3I Certain NP HC 50.312.001.01-2
12 Osstem TS NP HC 50.312.029.01-2
13 Nobel Biocare Replace 3.5 TA 50.312.026.01-2
14 Nobel Biocare Replace 4.3 TB 50.313.027.01-2
15 Straumann Bone Level NP SA 50.312.033.01-2
16 Straumann Bone Level RP SB 50.313.035.01-2
17 Nobel Biocare Multi-Unit RP MA 50.313.025.01-2 X18 Straumann Synocta 4.8 OA 50.313.074.01-2 X19 Straumann Internal Octagon 4.8 OA 50.313.037.01-2
20 Biomet 3I Osseotite 3.3 HD 50.312.003.01-2 X
COLORES SISTEMA INTRAORAL SEGÚN COMPATIBILIDAD TIPO DE SCANBODY SEGÚN COMPATIBILIDAD
SCANBODY COMPATIBLE CON:
HA Nobel Biocare Branemark RPZimmer Screw-Vent 3.5Nobel Biocare Active RPBiomet 3I Certain RPOsstem Implant TS RPBiomet 3I Osseotite RP
HB Zimmer Screw-Vent 4.5Astra Lilac WPBiohorizons 4.5
HC Nobel Biocare Branemark NPAstra Aqua RPNobel Biocare Active NPBiomet 3I Certain NPOsstem Implant TS NP
HD Biomet 3I Osseotite NP
TA Nobel Biocare Replace 3.5Implant Direct Replus 3.5
TB Nobel Biocare Replace 4.3Implant Direct Replus 4.3
SA Straumann Bone Level NP
SB Straumann Bone Level RP
MA Nobel Biocare Multi-Unit RP
OA Straumann Synocta RPStraumann Internal Octagon 4.8
28 29 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Abarcan todas las métricas de rosca de implante disponibles en el mercado. Se utilizan junto al Pilar Dinámico® 3.0, a la Interfase Dinámica® 3.0 o para estructuras fresadas con canal de orificio de tornillo angulado hasta 30° por ello disponemos de varias longitudes de cada métrica para facilitar la adaptación a sus estructuras.Todos están fabricados en Titanio grado V.
Abarcan todas las métricas de rosca de implante disponibles en el mercado. Disponibles varias longitudes de cada métrica para facilitar la adaptación a sus estructuras fresadas.Fabricados en Titanio grado V.
TORNILLOS RECTOSTORNILLOS DINÁMICOS
DESTORNILLADOR DINÁMICO
HEXALOBULAR 1.70 mmREF: 43.618.201.01-2: PD 18mm
HEXALOBULAR 1.70 mmREF: 43.624.201.01-2: PD 24mm
HEXALOBULAR 1.70 mmREF: 43.632.201.01-2: PD 32mm
DESTORNILLADORES PARATORNILLOS RECTOS
REF: 43.601.103.02-2 Hex 1.20mm
REF: 43.601.104.01-2Hex 1.25mm
REF: 43.601.105.01-2Hex. 1.27mm
REF: 43.601.102.01-2Cuad. 1.30mm
REF: 43.601.108.01-2Unigrip
REF: 43.601.107.01-2Torx 25mm
Destornillador con cabeza hexalobular, exclusivo del sistema Pilar Dinámico® 3.0; longitudes: 18 -24 -32mm.Vástago con conexiónpara contra ángulo parafacilitar su uso concarraca dinamométricao manual mediante losadaptadores o mangos correspondientes.
COMPLEMENTOS
Mango manual para clínicaRef. 49.601.000.01-2
Mango manual largo para laboratorio Ref.49.601.000.03-2
Carraca UniversalRef. 11.990.990.07-2
Adaptadores para carracaMango manualFabricados en acero inoxidable. Se utilizan para conectar las puntas de destornillador con conexión de contra ángulo.
Destornillador para el adaptador del Sistema Intraoral.
Ideal para la manipulación de modelos en el laboratorio. Longitud: 55,65mm.
Mango de clínica: se utiliza para colocar la prótesis en boca antes del control de torque en la clínica. Longitud: 15,65mm
Carraca dinamométrica de conexión cuadrada de 4mm. Torque 10-35N.cm
Pieza que conecta la punta de destornillador con conexión a contra-ángulo con la carraca dinamométrica.
Ref. 49.604.000.05-2
Ref. 49.604.000.07-2
Ref. 49.604.000.08-2
Conexión cuadrada 4mm
Conexión tipo Straumann
Adaptadores para carraca universal
Adaptadores para carraca Straumann
Adaptadores para carraca Nobel Biocare
DESTORNILLADOR
SISTEMA INTRAORAL
Ref. 43.624.410.01-2 (Longitud 24mm)
Ref. 43.630.410.01-2 (Longitud 30mm)
30 31 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
33. 4 45 . 80 4 .01-2Mango
Asentamiento
Longitudútil
Código diametrode corte
Código Referencia:
Dynamic Milling Tool
DYNAMIC MILLING TOOL ESPECIFICACIONES
CONEXIÓN REFERENCIA DIÁMETRO DE CORTE ASENTAMIENTO LONGITUD DE TRABAJO
(max drilling depht)DIÁMETRO SOPORTE
(MANGO)LONGITUD
TOTAL
Øc α α Lu Øs Lt
STRAUMANN BONE LEVEL NPSTRAUMANN BONE LEVEL RP
33.315.804.01-2 1,6 15 8 3 50
33.415.804.01-2 1,6 15 8 4 50
33.615.804.01-2 1,6 15 8 6 50
NOBEL BIOCARE ACTIVE NP
33.335.754.01-2 1,6 35 7,5 3 50
33.435.754.01-2 1,6 35 7,5 4 50
33.635.754.01-2 1,6 35 7,5 6 50
OSSTEM TS NP
33.345.804.01-2 1,6 45 8 3 50
33.445.804.01-2 1,6 45 8 4 50
33.645.804.01-2 1,6 45 8 6 50
BIOMET 3I CERTAIN NPASTRA AQUA
33.390.754.01-2 1,6 90 7,5 3 50
33.490.754.01-2 1,6 90 7,5 4 50
33.690.754.01-2 1,6 90 7,5 6 50
BIOMET 3I CERTAIN RPNOBEL BIOCARE BRANEMARK NP
NOBEL BIOCARE REPLACE NP
33.390.805.01-2 1,7 90 8 3 50
33.490.805.01-2 1,7 90 8 4 50
33.690.805.01-2 1,7 90 8 6 50
ZIMMER SCREW-VENT 3.5ZIMMER SCREW-VENT 4.5
33.370.716.01-2 1,8 70 7,1 3 50
33.470.716.01-2 1,8 70 7,1 4 50
33.670.716.01-2 1,8 70 7,1 6 50
NOBEL BIOCARE BRANEMARK RP NOBEL BIOCARE MULTI-UNIT RP
BIOMET 3I OSSEOTITE NP
33.390.716.01-2 1,8 90 7,1 3 50
33.490.716.01-2 1,8 90 7,1 4 50
33.690.716.01-2 1,8 90 7,1 6 50
STRAUMANN INTERNAL OCTAGON RP
33.315.708.01-2 2 15 7 3 50
33.415.708.01-2 2 15 7 4 50
33.615.708.01-2 2 15 7 6 50
STRAUMANN SYNOCTA RP
33.330.708.01-2 2 30 7 3 50
33.430.708.01-2 2 30 7 4 50
33.630.708.01-2 2 30 7 6 50
NOBEL BIOCARE ACTIVE RP
33.335.758.01-2 2 35 7,5 3 50
33.435.758.01-2 2 35 7,5 4 50
33.635.758.01-2 2 35 7,5 6 50
OSSTEM TS RP
33.345.808.01-2 2 45 8 3 50
33.445.808.01-2 2 45 8 4 50
33.645.808.01-2 2 45 8 6 50
NOBEL BIOCARE REPLACE RPASTRA LILAC
33.390.958.01-2 2 90 9,5 3 50
33.490.958.01-2 2 90 9,5 4 50
33.690.958.01-2 2 90 9,5 6 5032 DYNAMIC ABUTMENT® SOLUTIONS
ÁREA DE CORTE
3 ALETAS DE CORTE
34 DYNAMIC ABUTMENT® SOLUTIONS
TORNILLOS DINÁMICOS - ESPECIFICACIONES TÉCNICAS
REFERENCIA MÉTRICA TORQUELONG. TOTAL
LONG. ROSCA
LONG. A
LONG. B
LONG. C
DIÁM. CABEZA
ASENTAMIENTO ÁNGULOENTRADA ROSCA
CONEXIÓN
41.314.039.01-2 1,4 15 N•cm 3,90 1,80 2,10 - 1,80 2,40 recto - Chaflán 45º
Hexalobular1,70
41.314.040.01-2 1,4 15 N•cm 4,00 1,85 2,00 2,78 1,22 2,30 cónico 30º Chaflán 45º
41.314.045.01-2 1,4 15 N•cm 4,50 2,30 2,50 3,28 1,22 2,30 cónico 30º Chaflán 45º
41.314.052.01-2 1,4 15 N•cm 5,20 2,90 3,40 - 1,80 2,30 recto - Chaflán 45º
41.314.064.01-2 1,4 15 N•cm 6,40 2,20 4,21 5,15 1,25 2,30 cónico 25º Chaflán 45º
41.314.067.01-2 1,4 15 N•cm 6,70 2,31 5,00 5,45 1,25 2,30 cónico 45º Chaflán 45º
41.314.070.01-2 1,4 15 N•cm 7,00 2,30 5,39 5,65 1,61 2,30 cónico 60º Chaflán 45º
41.314.074.01-2 1,4 15 N•cm 7,40 3,55 5,00 5,99 1,41 2,30 cónico 25º Chaflán 45º
41.316.044.01-2 1,6 20 N•cm 4,40 2,50 2,90 - 1,50 2,30 recto - Semiesférica
41.316.059.01-2 1,6 20 N•cm 5,90 3,00 4,40 - 1,50 2,30 recto - Semiesférica
41.316.071.01-2 1,6 20 N•cm 7,10 2,80 5,20 5,53 1,57 2,30 cónico 60º Chaflán 45º
41.316.072.01-2 1,6 20 N•cm 7,20 3,50 5,20 5,85 1,35 2,30 cónico 30º Chaflán 45º
41.316.073.01-2 1,6 20 N•cm 7,30 2,20 4,87 5,56 1,74 2,30 cónico 35º Chaflán 45º
41.316.074.01-2 1,6 20 N•cm 7,40 2,70 5,50 6,00 1,40 2,30 cónico 45º Chaflán 45º
41.316.076.01-2 1,6 20 N•cm 7,60 3,60 6,10 - 1,50 2,30 recto - Semiesférica
41.316.078.01-2 1,6 20 N•cm 7,80 2,00 5,36 7,03 0,81 2,30 cónico 15º Chaflán 45º
41.316.081.01-2 1,6 20 N•cm 8,10 3,00 6,35 6,72 1,38 2,30 cónico 45º Chaflán 45º
41.316.084.01-2 1,6 20 N•cm 8,40 3,50 6,80 - 1,60 2,30 recto - Semiesférica
41.316.094.01-2 1,6 20 N•cm 9,40 2,90 7,65 8,00 1,40 2,30 cónico 45º Chaflán 45º
41.317.065.01-2 N1-72 25 N•cm 6,50 2,40 4,70 5,18 1,33 2,30 cónico 45º Chaflán 45º
41.317.071.01-2 N1-72 25 N•cm 7,10 2,60 5,56 5,65 1,45 2,30 cónico 70º Chaflán 45º
41.317.073.01-2 N1-72 25 N•cm 7,30 2,50 5,50 5,77 1,53 2,30 cónico 60 Chaflán 45º
41.318.044.01-2 1,8 25 N•cm 4,40 2,75 3,00 - 1,40 2,30 recto - Semiesférica
41.318.045.01-2 1,8 25 N•cm 4,50 2,30 2,81 2,90 1,60 2,30 cónico 70º Chaflán 45º
41.318.048.01-2 1,8 25 N•cm 4,80 2,80 3,22 3,65 1,15 2,30 cónico 30º Semiesférica
41.318.051.01-2 1,8 25 N•cm 5,10 2,70 3,55 3,70 1,40 2,30 cónico 60º Chaflán 45º
41.318.052.01-2 1,8 25 N•cm 5,20 2,90 3,65 3,80 1,40 2,30 cónico 60º Chaflán 45º
REFERENCIA MÉTRICA TORQUELONG. TOTAL
LONG. ROSCA
LONG. A
LONG. B
LONG. C
DIÁM. CABEZA
ASENTAMIENTO ÁNGULOENTRADA ROSCA
CONEXIÓN
41.318.064.01-2 1,8 25 N•cm 6,40 3,45 4,73 5,10 1,30 2,30 cónico 35º Chaflán 45º
Hexalobular1,70
41.318.065.01-2 1,8 25 N•cm 6,50 2,80 5,00 - 1,50 2,30 recto - Semiesférica
41.318.066.01-2 1,8 25 N•cm 6,60 4,18 5,05 5,20 1,40 2,30 cónico 60º Chaflán 45º
41.318.067.01-2 1,8 25 N•cm 6,70 2,35 5,00 5,40 1,30 2,30 cónico 45º Chaflán 45º
41.318.068.01-2 1,8 25 N•cm 6,80 4,00 5,25 5,40 1,40 2,30 cónico 60º Chaflán 45º
41.318.071.01-2 1,8 25 N•cm 7,10 2,60 5,56 5,65 1,45 2,30 cónico 70º Chaflán 45º
41.318.074.01-2 1,8 25 N•cm 7,40 3,80 5,80 6,03 1,60 2,30 cónico 50º Chaflán 45º
41.318.075.01-2 1,8 25 N•cm 7,50 3,30 6,10 - 1,40 2,30 recto - Semiesférica
41.318.076.01-2 1,8 25 N•cm 7,60 2,52 5,80 6,20 1,40 2,30 cónico 45º Chaflán 45º
41.318.080.01-2 1,8 25 N•cm 8,00 4,00 6,50 - 1,50 2,30 recto - Chaflán 45º
41.320.047.01-2 2,0 25 N•cm 4,70 3,00 3,30 - 1,40 2,30 recto - Semiesférica
41.320.048.01-2 2,0 25 N•cm 4,80 2,70 3,30 3,40 1,40 2,30 cónico 60º Chaflán 45º
41.320.049.01-2 2,0 25 N•cm 4,90 2,90 3,40 3,50 1,40 2,30 cónico 60º Chaflán 45º
41.320.050.01-2 2,0 25 N•cm 5,00 2,80 3,39 3,60 1,40 2,30 cónico 30º Semiesférica
41.320.051.01-2 2,0 25 N•cm 5,10 3,10 3,60 - 1,50 2,30 recto - Semiesférica
41.320.060.01-2 2,0 25 N•cm 6,00 2,70 4,50 - 1,50 2,30 recto - Semiesférica
41.320.065.01-2 2,0 25 N•cm 6,50 2,70 5,00 - 1,50 2,30 recto - Chaflán 45º
41.320.066.01-2 2,0 25 N•cm 6,60 4,18 5,11 5,20 1,40 2,30 cónico 60º Chaflán 45º
41.320.067.01-2 2,0 25 N•cm 6,70 2,30 3,65 5,68 1,02 2,58 cónico 15º Chaflán 45º
41.320.068.01-2 2,0 25 N•cm 6,80 4,40 5,30 5,40 1,40 2,30 cónico 60º Chaflán 45º
41.320.070.01-2 2,0 25 N•cm 7,00 3,00 5,60 - 1,40 2,30 recto - Semiesférica
41.320.074.01-2 2,0 25 N•cm 7,40 3,30 6,00 - 1,40 2,30 recto - Semiesférica
41.320.075.01-2 2,0 25 N•cm 7,50 2,75 5,93 6,18 1,32 2,30 cónico 35º Chaflán 45º
41.320.079.01-2 2,0 25 N•cm 7,90 3,30 6,33 6,50 1,40 2,30 cónico 45º Chaflán 45º
41.320.082.01-2 2,0 25 N•cm 8,20 4,70 6,70 - 1,50 2,40 recto - Semiesférica
41.320.090.01-2 2,0 25 N•cm 9,00 4,00 7,50 - 1,50 2,30 recto - Semiesférica
41.320.094.01-2 2,0 25 N•cm 9,4 3,00 7,85 8,00 1,40 2,30 cónico 45º Chaflán 45º
41.325.054.01-2 2,5 25 N•cm 5,40 3,80 4,10 - 1,30 2,85 recto - Semiesférica
41.325.067.01-2 2,5 25 N•cm 6,70 4,60 5,10 - 1,60 2,85 recto - Semiesférica
Long. rosca
Asentam
iento
Conexión
Entradarosca
Long. A
Longitud
Long. C Ø Cabeza
Long.rosca
Ángulo
Conexión
Entradarosca
Long. A
Long. BLong. C
Longitud
Ø Cabeza
36 DYNAMIC ABUTMENT® SOLUTIONS 37 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
TORNILLOS RECTOS - ESPECIFICACIONES TÉCNICAS
REFERENCIA MÉTRICA TORQUELONG. TOTAL
LONG. ROSCA
LONG. A
LONG. B
LONG. C
DIÁM. CABEZA
ASENTAMIENTO ÁNGULOENTRADA ROSCA
CONEXIÓN
40.314.008.01-2 1,4 15 N·cm 3,5 1,8 2,1 - 1,4 2 recto - Chaflán 45º Unigrip
40.314.003.01-2 1,4 15 N·cm 3,9 1,91 2,1 - 1,8 2,4 recto - Chaflán 45º Hex. 1,20
40.314.005.01-2 1,4 15 N·cm 7,6 3,55 5,17 6 1,6 2,15 cónico 25º Chaflán 45º Hex. 1,27
40.316.002.01-2 1,6 20 N·cm 7 2,79 4,86 5,44 1,56 2,3 cónico 45º Chaflán 45º Cuad. 1,30
40.316.008.01-2 1,6 20 N·cm 7 2,7 5,15 - 1,8 2,3 recto - Chaflán 45º Unigrip
40.316.008.02-2 1,6 20 N·cm 7,3 2,7 5,15 5,9 1,4 2,2 cónico 35º Chaflán 45º Unigrip
40.316.005.01-2 1,6 20 N·cm 7,5 3,6 5,33 5,85 1,65 2,15 cónico 30º Chaflán 45º Hex. 1,27
40.316.007.01-2 1,6 20 N·cm 7,9 2 5,72 6,9 2,18 2,18 cónico 15º Chaflán 45º Torx T6
40.316.005.02-2 1,6 20 N·cm 8,2 3,03 6,25 - 2 2,33 recto - Chaflán 45º Hex. 1,27
40.316.005.03-2 1,6 20 N·cm 8,25 3,03 6,25 - 2 2,45 recto - Chaflán 45º Hex. 1,27
40.316.003.01-2 1,6 20 N·cm 8,4 2,5 6,6 - 1,8 2 recto - Chaflán 45º Hex. 1,20
40.316.002.02-2 1,6 20 N·cm 9,3 3,3 7,3 - 2 2,3 recto - Semiesférica Cuad. 1,30
40.316.005.04-2 1,6 20 N·cm 10,5 2,9 8,15 8,4 2,1 2,1 cónico 45º Chaflán 45º Hex. 1,27
40.317.004.01-2 N1-72 25 N·cm 7,6 2,8 5,6 5,76 1,84 2,3 cónico 70º Chaflán 45º Hex. 1,27
40.318.005.01-2 1,8 25 N·cm 4,5 2,3 2,8 2,9 1,6 2,35 cónico 70º Chaflán 45º Hex. 1,27
40.318.006.01-2 1,8 25 N·cm 6 3,18 3,5 3,85 2,15 2,4 cónico 45º Chaflán 45º Hex. 1,50
40.318.003.01-2 1,8 25 N·cm 6,8 3,3 5,2 - 1,6 2,3 recto - Chaflán 45º Hex. 1,20
40.318.002.01-2 1,8 25 N·cm 7 3,2 5,2 - 1,8 2,5 recto - Chaflán 45º Cuad. 1,30
40.318.004.01-2 1,8 25 N·cm 7,2 4,47 2,3 6,2 1 2,4 cónico 30º Chaflán 45º Hex. 1,25
40.318.005.02-2 1,8 25 N·cm 7,6 3,8 5,8 6,05 1,55 2,35 cónico 50º Chaflán 45º Hex. 1,27
40.318.008.01-2 1,8 25 N·cm 8,3 2,5 6,5 - 1,8 2,45 recto - Chaflán 45º Unigrip
40.318.004.02-2 1,8 25 N·cm 9,8 5,094 8,3 8,8 1 2,4 cónico 30º Chaflán 45º Hex. 1,25
40.318.002.02-2 1,8 25 N·cm 8,3 2,6 6,6 - 1,7 2,45 recto - Chaflán 45º Cuad. 1,30
REFERENCIA MÉTRICA TORQUELONG. TOTAL
LONG. ROSCA
LONG. A
LONG. B
LONG. C
DIÁM. CABEZA
ASENTAMIENTO ÁNGULOENTRADA ROSCA
CONEXIÓN
40.320.003.01-2 2 30 N·cm 4,7 2,7 3,33 - 1,37 2,35 recto - Chaflán 45º Hex. 1,20
40.320.002.01-2 2 30 N·cm 5 3,06 3,26 3,5 1,5 2,49 cónico 45º Chaflán 45º Cuad. 1,30
40.320.007.01-2 2 30 N·cm 6,7 2,25 3,59 5,7 1 2,58 cónico 15º Chaflán 45º Torx T6
40.320.003.02-2 2 30 N·cm 7 3,25 5 - 2 2,4 recto - Chaflán 45º Hex. 1,20
40.320.008.01-2 2 30 N·cm 7 3,25 5 - 2 2,4 recto - Chaflán 45º Unigrip
40.320.008.02-2 2 30 N·cm 7,3 3 5,8 6,2 1,1 2,5 cónico 35º Chaflán 45º Unigrip
40.320.007.02-2 2 30 N·cm 7,4 3,3 6 - 1,4 2,3 recto - Semiesférica Torx T6
40.320.003.03-2 2 30 N·cm 7,9 3,7 5,55 6,05 1,8 2,4 cónico 45º Chaflán 45º Hex. 1,20
40.320.002.02-2 2 30 N·cm 7,45 3 5,7 5,9 1,5 2,4 cónico 45º Chaflán 45º Cuad. 1,30
40.320.007.03-2 2 30 N·cm 7,6 3 6,1 6,3 1,3 2,4 cónico 45º Semiesférica Torx T6
40.320.005.01-2 2 30 N·cm 7,6 3,7 6 - 1,6 2,4 recto - Chaflán 45º Hex. 1,27
40.320.008.03-2 2 30 N·cm 10 3,6 8,5 - 1,5 2,45 recto - Chaflán 45º Unigrip
40.320.002.03-2 2 30 N·cm 10,2 3,15 8,4 - 1,8 2,45 recto - Chaflán 45º Cuad. 1,30
40.320.005.02-2 2 30 N·cm 10,3 4 8,3 - 2 2,45 recto - Chaflán 45º Hex. 1,27
40.320.005.03-2 2 30 N·cm 10,3 3,5 8,3 - 2 2,33 recto - Chaflán 45º Hex. 1,27
40.320.005.04-2 2 30 N·cm 10,5 3,06 8,15 8,4 2,1 2,5 cónico 45º Chaflán 45º Hex. 1,27
40.325.002.01-2 2,5 30 N·cm 7,41 3,5 4,75 5,29 2,12 2,87 cónico 45º Semiesférica Cuad. 1,30
Long. rosca
Asentamiento
Conexión
Entradarosca
Long. A
Longitud
Long. C
Ø C
abez
a
Long.roscaÁngulo
Conexión
Entradarosca
Long. A
Long. BLong. C
Longitud
Ø C
abez
a
38 39 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
I2
3,5/3,75/4,2/4,5/Standard
52.410.101.01-2 10 DAS_I_10_004050.312.040.01-2 34.612.040.01-2
31.322.040.01-2 R0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5/6 Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
I22 3,75/4,22 Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
I5
3,5/3,75/4,2/4,5/ Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5/6/7/8 Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
I55
3,75/4,2/4,5 Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5/6/7/8 Standard52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Compatible con - AB
40 41 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ACE
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
HexágonoExterno
3,3 NP 3,552.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
3,75/4 RP 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Infinity TRI-CAM
3,5 3,5
52.410.108.01-2 10 DAS_I_10_0026
50.312.026.01-2 34.612.026.01-2
31.322.026.01-2
31.312.026.01-2
31.322.026.02-2
31.312.026.02-2
R
NR
R
NR
0,5
1,2
41.318.075.01-2 40.318.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.108.01-2 12 DAS_I_12_0026
4,3 4,3
52.410.109.01-2 10 DAS_I_10_0027
50.313.027.01-2 34.613.027.01-2
31.323.027.01-2
31.313.027.01-2
31.323.027.02-2
31.313.027.02-2
R
NR
R
NR
0,3
1,2
41.320.090.01-2 40.320.008.03-2 32.213.027.01-2 32.313.027.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.109.01-2 12 DAS_I_12_0027
Infinity Hexágono Interno
3,7/4,1 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,7/5,1 4,552.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
42 43 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ADIN
Touareg CloseFit
3,5 RP 52.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
4,3/5 WP
52.410.101.01-2 10 DAS_I_10_0022
50.313.022.01-2 34.613.022.01-2
31.323.022.01-2
31.313.022.01-2
31.323.022.02-2
31.313.022.02-2
R
NR
R
NR
1,3
2
41.320.075.01-2 40.320.008.02-2 32.213.022.01-2 32.313.022.01-2
33.335.758.01-2
33.435.758.01-2
33.635.758.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0022
Touareg-S / Touareg-OS
3,5 3,4552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,75/4,2 3,652.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5 452.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
6 552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Swell
3,3 3,45 52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,75/4,2 3,652.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5 452.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
6 4,652.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
44 45 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ALPHABIO
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
SPI 3,3/3,75/4,2/5/6 Universal52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.490.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
ICE 3,7/3,75/4,2/4,65/5,3 Universal52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
DFI 3,3/3,75/4,2/4,5 Universal52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.470.716.01-2
33.670.716.01-2
33.370.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
ATID 3,3/3,75/4,2/5/6 Universal52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.470.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
46 47 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ANCLADEN
Compatible con - ANTHOGYR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Anclalock 3,75/4,25/5 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Anthofit HE 3,5/3,75/4 R (4,1)52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.065.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Ossfit 3,5/4,2 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
48 49 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ARDS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Smart 3,75/4,2/4,5 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Classic
3,75/4,2/4,5 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,3/3,75/4,2/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Premium 3,3/3,75/4,2/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
50 51 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ASTRA
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Aqua 3,5/4 Aqua
52.410.103.01-210
DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
Lilac 4,5/5 Lilac
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
52 53 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - AVINENT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
HE 3,3/3,8/4/4,2/4,8//4,5/5 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
HI
3,1//3,5/4 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,3/3,8/4/4,2/4,8//4,5/5 4,152.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Transepitelial Regular 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
6
54 55 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIOGENESIS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
3icon
3,3 Mini (Pink)52.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
3,75/4/4,3/4,5 Regular (Blue)52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Aticon 3,5//4/4,5/5 Pink/Blue
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
Iticon 3,5/4,1/4,8 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
56 57 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIOHORIZON
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Tapered Interno
3/3,8/4,6 3,5 (Yellow)52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,6/5,8 4,5 (Green)52.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
Interno
3,5/4 3,5 (Yellow)52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4/5 4,5 (Green)52.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
58 59 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIOMET 3I
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Osseotite
3,25 3,452.410.104.01-2 10 DAS_I_10_0003
50.312.003.01-2 34.612.003.01-231.322.003.01-2 R
0,3 41.320.065.01-2 40.320.003.02-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.104.01-2 12 DAS_I_12_0003 31.312.003.01-2 NR
4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Certain
3,25/4 3,4
52.410.103.01-2 10 DAS_I_10_0001
50.312.001.01-2 34.612.001.01-2
31.322.001.01-2
31.312.001.01-2
31.322.001.02-2
31.312.001.02-2
R
NR
R
NR
0,3
1,2
41.316.084.01-2 40.316.003.01-2 -- --
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0001
4/5 4,1
52.410.101.01-2 10 DAS_I_10_0002
50.313.002.01-2 34.613.002.01-2
31.323.002.01-2
31.313.002.01-2
31.323.002.02-2
31.313.002.02-2
R
NR
R
NR
0,3
1,2
41.316.084.01-2 40.316.003.01-2 32.213.002.01-2 32.313.002.01-2
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0002
Low Profile Universal 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
6
60 61 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIOLOK
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Hexágono Externo 3,45 3,45 52.410.104.01-2 10 DAS_I_10_0003 50.312.003.01-2 34.612.003.01-231.322.003.01-2 R
0,3 41.320.065.01-2 40.320.003.02-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
631.312.003.01-2 NR
62 63 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIONER
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Ikelt / Bikelt 3,3/3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Hikelt
3,8 3,9552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,7 4,952.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
TopDM
3,5 3,552.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
4 452.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
5 552.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
Transepitelial A-5M Regular 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
6
64 65 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BIOTEC
Compatible con - BTI
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
SPR/CIM
3,3 3,352.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,75 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SPR/SPTT/CIM
4,2 4,252.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5 552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Conexión Externa 3,75/4/4,5/5 Universal 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
66 67 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - BTK
Compatible con - B&W
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Klassic / Konic
3,25PL/3,75/4 4,1 ER52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
3,25/4 3,5 IR52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Hexágono Externo 3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
68 69 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - CONEXÃO SISTEMA DE PRÓTESE
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Flash 3,5/4,3/5 Universal52.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
Torq 3,5/3,75/4 Universal52.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
Expand 3,75/4/5 Universal52.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
70 71 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - CORTEX
Compatible con - DENTAL TECH
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Dynamix 3,3/3,8/4,2/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Classix 3,3/3,8/4,2/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Saturn 3,8/4,2 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Plataforma Cónica 3,3/3,8/4,2 RP52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-231.323.004.01-2 R
1 41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004 31.313.004.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Implogic 4,5 4,5 (Blue)52.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
72 73 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - DENTIS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
s-Clean
3,7 Mini
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,1/4,3 Regular
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,8 Wide
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
74 75 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - DENTIUM
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
SimpleLine II 3,8/4,3 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
SuperLine &Implantium
3,4 3,6
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
3,8 4
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,3 4,5
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,8 5
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,8 6
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
76 77 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - DIO IMPLANTS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
UF II 3,8/4/4,5/5/5,5 Regular
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030 41.320.079.01-2 -- -- --
Externo 3,75/4/4,5 Regular 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
78 79 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - DSP BIOMEDICAL
Compatible con - ECKERMANN
Compatible con - ELITE MEDICAL
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Hexágono Externo 3,75/4/5//3,5/3,8/4,3 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.065.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Hexágono 3/3,5/4/4,5/5 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Conexión Externa
Narrow52.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
Regular52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
80 81 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - EUROTEKNIKA
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Naturactis
3,5 3,4
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
4 3,8
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
4,5 4,3
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
5 4,8
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
82 83 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - EUROTEKNIKA
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Uneva
3,6 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
4,1 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Uneva (Platform Switching)
4,8 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
6 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Natea
3,6/4,1/4,8 Narrow
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
3,6/4,1/4,8 Regular
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
6Wide
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
84 85 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - EUROTEKNIKA
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Aesthetica 4,1 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
Naturall
3,5 Narrow
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
4/4,5 Regular
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
5 Wide
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
86 87 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - GALIMPLANT
Compatible con - GMI (ILERIMPLANT)
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Conexión Externa 3,5/4 452.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.065.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Conexión Interna 4 4
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL SHANK
Phoenix 3,3/3,75/4 Standard 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
88 89 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - GT MEDICAL
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Best Fit Octógono Interno 3,7/4,3/4,8 Regular
52.410.110.01-2 10 DAS_I_10_003750.313.037.01-2 34.613.037.01-2
31.323.037.01-2 R0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
Best Fit Hexágono Interno 3,7/4,1/4,3/4,8 Wide
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
Best Fit Hexágono Externo
3,5 Narrow52.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
4,1 Regular52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
90 91 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - HI-TECH
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Tapered Self Thread
3,3/3,75 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,2/5 4,552.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
Logic Plus
3,5 3,752.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,3 3,952.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
92 93 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - IHDE DENTAL (IMBIODENT)
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Bone Level Plus
3,3 3,3
52.410.106.01-2 10 DAS_I_10_0033
50.312.033.01-2 34.612.033.01-2
31.322.033.01-2
31.312.033.01-2
31.322.033.02-2
31.312.033.02-2
R
NR
R
NR
1,3
2
41.316.078.01-2 40.316.007.01-2 -- --
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.106.01-2 12 DAS_I_12_0033
4,1 4,1
52.410.107.01-2 10 DAS_I_10_0035
50.313.035.01-2 34.613.035.01-2
31.323.035.01-2
31.313.035.01-2
31.323.035.02-2
31.313.035.02-2
R
NR
R
NR
1,1
2
41.316.078.01-2 40.316.007.01-2 32.213.035.01-2 32.313.035.01-2
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.107.01-2 12 DAS_I_12_0035
4,8 4,8
52.410.107.01-2 10 DAS_I_10_0035
50.313.035.01-2 34.613.035.01-2
31.323.035.01-2
31.313.035.01-2
31.323.035.02-2
31.313.035.02-2
R
NR
R
NR
1,1
2
41.316.078.01-2 40.316.007.01-2 32.213.035.01-2 32.313.035.01-2
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.107.01-2 12 DAS_I_12_0035
94 95 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - IMPLANT DIRECT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
RePlus / Replant / Reactive
3,5/3,7/4,2 3,5
52.410.108.01-2 10 DAS_I_10_0026
50.312.026.01-2 34.612.026.01-2
31.322.026.01-2
31.312.026.01-2
31.322.026.02-2
31.312.026.02-2
R
NR
R
NR
0,5
1,2
41.318.075.01-2 40.318.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.108.01-2 12 DAS_I_12_0026
4,3/4,7 4,3
52.410.109.01-2 10 DAS_I_10_0027
50.313.027.01-2 34.613.027.01-2
31.323.027.01-2
31.313.027.01-2
31.323.027.02-2
31.313.027.02-2
R
NR
R
NR
0,3
1,2
41.320.090.01-2 40.320.008.03-2 32.213.027.01-2 32.313.027.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.109.01-2 12 DAS_I_12_0027
Legacy
3,7 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,7 4,552.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
Swishplant / Swishplus 4,1/4,8 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
96 97 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - IMPLANT DIRECT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
SwishActive
3,3 352.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
4,1/4,8 3,4
52.410.101.01-2 10 DAS_I_10_0022
50.313.022.01-2 34.613.022.01-2
31.323.022.01-2
31.313.022.01-2
31.323.022.02-2
31.313.022.02-2
R
NR
R
NR
1,3
2
41.320.075.01-2 40.320.008.02-2 32.213.022.01-2 32.313.022.01-2
33.335.758.01-2
33.435.758.01-2
33.635.758.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0022
Interactive
3,2/3,7 352.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
4,3/5 3,4
52.410.101.01-2 10 DAS_I_10_0022
50.313.022.01-2 34.613.022.01-2
31.323.022.01-2
31.313.022.01-2
31.323.022.02-2
31.313.022.02-2
R
NR
R
NR
1,3
2
41.320.075.01-2 40.320.008.02-2 32.213.022.01-2 32.313.022.01-2
33.335.758.01-2
33.435.758.01-2
33.635.758.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0022
98 99 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - JDENTALCARE
Compatible con - KEYSTONE
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
JDEvolution/JDEvolution Plus
3,7 3,752.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,3/5 452.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
6 552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Restore 3,75/4 RD 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
100 101 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - KLOCKNER
Compatible con - LEADER
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
KL 4,1 Regular52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Tixos Hexágono Interno
3,3 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
3,75 452.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Tixos Hexágono Externo 3,3/3,75 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
102 103 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - MEGAGEN
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
AnyOne Interno 3,5/4/4,5/5/6/7 General
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
AnyOne Externo
4 Regular 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
4,5 Regular 4,552.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
104 105 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - MICRODENT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Universal 3,3/3,5/3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
106 107 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - MIS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Lance 3,75/4,2 Standard 52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Seven
3,75/4,2 Standard 52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5/6Wide
52.410.102.01-2 10 DAS_I_10_004150.313.041.01-2 34.613.041.01-2
31.323.041.01-2 R0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
M4
3,75/4,2 Standard 52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
5/6 Wide 52.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.213.041.01-2 32.313.041.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
108 109 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - MOZO-GRAU
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
MG Osseous
3,3 3,4 Mini 52.410.104.01-2 10 DAS_I_10_0003 50.312.003.01-2 34.612.003.01-231.322.003.01-2 R
0,3 41.320.065.01-2 40.320.003.02-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
631.312.003.01-2 NR
3,4/3,75/4,25 4,1 Standard52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
MG Inhex
3,75/4,25 2,8 Standard
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
5 3,8 Maxi
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
110 111 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - MPI
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Conexión Externa HE 3,3/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Conexión Interna CM
3,5/4 Regular
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
5 Wide
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
112 113 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - NEOBIOTECH
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
EB External System 3,5 Narrow52.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
IS Implant System
4 Regular 4
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
4,5 Regular 4,5
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
5 Wide 5
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2 -- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030
Multi-Unit 4,8 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
6
114 115 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - NEODENT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Cono Morse Mini Pilar Regular 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
346
Smart HE 3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.070.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
34652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
116 117 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - NOBEL BIOCARE
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Branemark
3,3 Narrow52.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.059.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
3,75/4 Regular52.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Multi-Unit Regular 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
6
Replace
3,5 Narrow
52.410.108.01-2 10 DAS_I_10_0026
50.312.026.01-2 34.612.026.01-2
31.322.026.01-2
31.312.026.01-2
31.322.026.02-2
31.312.026.02-2
R
NR
R
NR
0,5
1,2
41.318.075.01-2 40.318.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.108.01-2 12 DAS_I_12_0026
4,3 Regular
52.410.109.01-2 10 DAS_I_10_0027
50.313.027.01-2 34.613.027.01-2
31.323.027.01-2
31.313.027.01-2
31.323.027.02-2
31.313.027.02-2
R
NR
R
NR
0,3
1,2
41.320.090.01-2 40.320.008.03-2 32.213.027.01-2 32.313.027.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.109.01-2 12 DAS_I_12_0027
118 119 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - NOBEL BIOCARE
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Active
3,5 Narrow52.410.103.01-2 10 DAS_I_10_0021
50.312.021.01-2 34.612.021.01-231.322.021.01-2 R
1,5 41.316.073.01-2 40.316.008.02-2 -- --
33.335.754.01-2
33.435.754.01-2
33.635.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0021 31.312.021.01-2 NR
4,3/5 Regular
52.410.101.01-2 10 DAS_I_10_0022
50.313.022.01-2 34.613.022.01-2
31.323.022.01-2
31.313.022.01-2
31.323.022.02-2
31.313.022.02-2
R
NR
R
NR
1,3
2
41.320.075.01-2 40.320.008.02-2 32.213.022.01-2 32.313.022.01-2
33.335.758.01-2
33.435.758.01-2
33.635.758.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0022
120 121 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - NORMON
Compatible con - OSSEOLIFE (ZIACOM)
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Normoimplant HE 3,25/3,75/4,25/4,75 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Normoimplant HI 3,75/4,25/4,75 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
OEX 3,75/4,25 RP 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
122 123 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - OSSTEM IMPLANT
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
TS
3,5 Mini52.410.103.01-2 10 DAS_I_10_0029
50.312.029.01-2 34.613.029.01-231.322.029.01-2 R
1,2 41.316.094.01-2 40.316.005.04-2 -- --
33.345.804.01-2
33.445.804.01-2
33.645.804.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0029 31.312.029.01-2 NR
4/4,5/5/6/7 Regular
52.410.101.01-2 10 DAS_I_10_0030
50.313.030.01-2 34.613.030.01-2
31.323.030.01-2
31.313.030.01-2
31.323.030.02-2
31.313.030.02-2
R
NR
R
NR
1,1
2
41.320.079.01-2
-- -- --
33.345.808.01-2
33.445.808.01-2
33.645.808.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0030 41.320.079.01-2
US 3,75/4/4,5 Regular 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
124 125 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - OSTEOPLUS
Compatible con - PHIBO
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
She 3,75 / 4 452.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.065.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_1_12_0024 31.313.024.01-2 NR
Shi 3,3 / 3,75 / 4,2 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
TSH/BNT Serie 3 3,6 452.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
TSH/BNT Serie 4 4,2 452.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
126 127 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - PROCLINIC
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Cilindro Externo/Cónico Externo 3,75/4,25//3,5/4 4,1 Standard
52.410.101.01-2 10 DAS_I_10_002450.313.024.01-2 34.613.024.01-2
31.323.024.01-2 R0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Cilindro Interno/Cónico Interno 3,3/3,75/4,25/5//3,5/4/5 3,5
52.410.101.01-2 10 DAS_I_10_004050.312.040.01-2 34.612.040.01-2
31.322.040.01-2 R0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SP Octa 3,3/4,1/4,8 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
128 129 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - RADHEX
Compatible con - SGS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
PHE
3,5 3,552.410.103.01-2 10 DAS_I_10_0023
50.312.023.01-2 34.612.023.01-231.322.023.01-2 R
0,3 41.316.076.01-2 40.316.008.01-2 -- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0023 31.312.023.01-2 NR
4/4,5/5 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.065.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
P1 3,2/3,75/4,2/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
P7 3,2/3,75/4,2/4,5/5/6 3,7552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
130 131 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - SIGNO VINCES
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Duo 4,6 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.074.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Inttegra 3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.070.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
Compact 4,5 CM3,8
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2
32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004 41.316.076.01-2 40.316.005.02-2
Duocon
3,8 CM3,8
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2
32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004 41.316.076.01-2 40.316.005.02-2
4,6/5,5 CM4,6
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2
32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005 41.320.090.01-2 40.320.005.03-2
132 133 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - SOUTHERN IMPLANTS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Tri-Nex
3,5 3,5
52.410.108.01-2 10 DAS_I_10_0026
50.312.026.01-2 34.612.026.01-2
31.322.026.01-2
31.312.026.01-2
31.322.026.02-2
31.312.026.02-2
R
NR
R
NR
0,5
1,2
41.318.075.01-2 40.318.008.01-2
-- --
33.390.805.01-2
33.490.805.01-2
33.690.805.01-2
3
4
652.412.108.01-2 12 DAS_I_12_0026 41.318.075.01-2 40.318.008.01-2
4,3 4,3
52.410.109.01-2 10 DAS_I_10_0027
50.313.027.01-2 34.613.027.01-2
31.323.027.01-2
31.313.027.01-2
31.323.027.02-2
31.313.027.02-2
R
NR
R
NR
0,3
1,2
41.320.090.01-2 40.320.008.03-2
32.213.027.01-2 32.313.027.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.109.01-2 12 DAS_I_12_0027 41.320.090.01-2 40.320.008.03-2
IT Connection 3,3/4/4,1/4,9/5 4,8
52.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-2
31.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
Hexágono Externo
3,25 3,4 52.410.104.01-2 10 DAS_I_10_0003 50.312.003.01-2 34.612.003.01-2 31.322.003.01-2 R 0,3 41.320.065.01-2 40.320.003.02-2 -- --
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
6
3,75/4 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.003.02-2 32.213.024.01-2 32.313.024.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
134 135 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - SOUTHERN IMPLANTS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Deep Conical
3,5/4 2,95/3,1
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
5 4,1
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
Hexágono Interno 3,75/4,2/5 Universal52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
Compact Conical 4,8 4,8 52.410.111.01-2 10 DAS_I_10_0025 50.313.025.01-2 34.613.025.01-2 31.323.025.01-2 R 0,3 41.314.039.01-2 40.314.008.01-2 -- --
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
6
136 137 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - STRAUMANN
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Octógono Interno 3,3/4,1/4,8 Regular 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
Octógono Externo 3,3/4,1/4,8 Regular 4,852.410.110.01-2 10 DAS_I_10_0074
50.313.074.01-2 34.613.074.01-2-- --
-- 41.320.051.01-2 40.320.007.012 -- --
33.330.708.01-2
33.430.708.01-2
33.630.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0074 -- --
Bone Level
3,3 NC- 3,3
52.410.106.01-2 10 DAS_I_10_0033
50.312.033.01-2 34.612.033.01-2
31.322.033.01-2
31.312.033.01-2
31.322.033.02-2
31.312.033.02-2
R
NR
R
NR
1,3
2
41.316.078.01-2 40.316.007.01-2 -- --
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.106.01-2 12 DAS_I_12_0033
4,1 RC-4,1
52.410.107.01-2 10 DAS_I_10_0035
50.313.035.01-2 34.613.035.01-2
31.323.035.01-2
31.313.035.01-2
31.323.035.02-2
31.313.035.02-2
R
NR
R
NR
1,1
2
41.316.078.01-2 40.316.007.01-2 32.213.035.01-2 32.313.035.01-2
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.107.01-2 12 DAS_I_12_0035
4,8 RC-4,8
52.410.107.01-2 10 DAS_I_10_0035
50.313.035.01-2 34.613.035.01-2
31.323.035.01-2
31.313.035.01-2
31.323.035.02-2
31.313.035.02-2
R
NR
R
NR
1,1
2
41.316.078.01-2 40.316.007.01-2 32.213.035.01-2 32.313.035.01-2
33.315.804.01-2
33.415.804.01-2
33.615.804.01-2
3
4
652.412.107.01-2 12 DAS_I_12_0035
138 139 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - SYBRON IMPLANT SOLUTIONS
Compatible con - TITANIUM-FIX
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Endopore (Innova) 4,1 4,152.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
b-fix
3,5/4 Regular
52.410.103.01-2 10 DAS_I_10_0004
50.313.004.01-2 34.613.004.01-2
31.323.004.01-2
31.313.004.01-2
31.323.004.02-2
31.313.004.02-2
R
NR
R
NR
1
2
41.316.076.01-2 40.316.005.02-2 32.213.004.01-2 32.313.004.01-2
33.390.754.01-2
33.490.754.01-2
33.690.754.01-2
3
4
652.412.103.01-2 12 DAS_I_12_0004
4,5/5 Long
52.410.102.01-2 10 DAS_I_10_0005
50.314.005.01-2 34.614.005.01-2
31.324.005.01-2
31.314.005.01-2
31.324.005.02-2
31.314.005.02-2
R
NR
R
NR
1
2
41.320.090.01-2 40.320.005.03-2 32.214.005.01-2 32.314.005.01-2
33.390.958.01-2
33.490.958.01-2
33.690.958.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0005
140 141 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - TRI DENTAL IMPLANTS
Compatible con - TRINON
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
TRI-Vent 3,75/4,1/4,7 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 31.212.042.01-2 32.312.042.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R) NO ROTATORIO (NR)
ALTURAGINGIVAL
TORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Q2 3,5/3,75/4,5 452.410.101.01-2 10 DAS_I_10_0024
50.313.024.01-2 34.613.024.01-231.323.024.01-2 R
0,3 41.320.060.01-2 40.320.008.01-2 32.213.024.01-2 32.313.024.01-2
33.390.716.01-2
33.490.716.01-2
33.690.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0024 31.313.024.01-2 NR
QK 4 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
142 143 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - VULKAN IMPLANTS
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
IN-Hex 3,3/3,75/4,2/5 3,75
52.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-2
31.322.040.01-2 R
0,6 41.318.075.01-2 40.318.003.01-2 32.212.040.01-2 32.312.042.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
144 145 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
Compatible con - ZIMMER
SCANBODY INTRAORAL INTERFASE DINÁMICA® 3.0 TORNILLOS CILINDRO PRE-FRESADO DYNAMIC MILLING TOOL
MODELO Ø IMPLANTE PLATAFORMA SCANBODY ALTURA mmCOD. LIBRERIA
INTRAORAL ADAPTADOR RÉPLICA DIGITAL ROTATORIO (R)
NO ROTATORIO (NR)ALTURA
GINGIVALTORNILLO DINÁMICO
TORNILLO RECTO
CROMO-COBALTO TITANIO
DYNAMIC MILLING TOOL MANGO
Screw-Vent
3,7/4,1 3,552.410.101.01-2 10 DAS_I_10_0040
50.312.040.01-2 34.612.040.01-231.322.040.01-2 R
0,6 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.101.01-2 12 DAS_I_12_0040 31.312.040.01-2 NR
4,7 4,552.410.102.01-2 10 DAS_I_10_0041
50.313.041.01-2 34.613.041.01-231.323.041.01-2 R
0,4 41.317.071.01-2 40.317.004.01-2 32.212.040.01-2 32.312.040.01-2
33.370.716.01-2
33.470.716.01-2
33.670.716.01-2
3
4
652.412.102.01-2 12 DAS_I_12_0041 31.313.041.01-2 NR
Swiss-Plus 3,7/4,1/4,8 4,852.410.110.01-2 10 DAS_I_10_0037
50.313.037.01-2 34.613.037.01-231.323.037.01-2 R
0,6 41.320.067.01-2 40.320.007.01-2 32.213.037.01-2 32.313.037.01-2
33.315.708.01-2
33.415.708.01-2
33.615.708.01-2
3
4
652.412.110.01-2 12 DAS_I_12_0037 31.313.037.01-2 NR
146 147 DYNAMIC ABUTMENT® SOLUTIONS DYNAMIC ABUTMENT® SOLUTIONS
GARANTÍA TALLADIUMTÉRMINOS Y CONDICIONESEstos términos y condiciones de garantía (“TyC”) cubren toda la gama de productos de Talladium (“Productos”), fabricados por Talladium España S.L. y distribuidos por Geoda Medical, S.L. y otros distribuidoresoficiales.La garantía descrita en estos TyC es exclusivamente en beneficio del clínico (“Clínico”) y del protésico dental (“Técnico”) y no para beneficio de terceras personas o instituciones, incluidos los pacientes.
PERÍODO DE GARANTÍATalladium España S.L ofrece una garantía de por vida en toda su gama de productos desde la fecha de comercialización.
ÁMBITO DE LA GARANTÍASujeto a lo establecido en las limitaciones y excepciones descritas en estos TyC, Talladium España S.L ofrecerá los siguentes beneficios:
CALIDAD: Si el Producto presenta defectos en los materiales o en la fabricación, Talladium España S.L. repondrá el Producto sin coste adicional.
SEGURIDAD:Si por un fallo en el sistema del Pilar Dinámico®, habiendo cumplido con todas las indicaciones del producto, se tuviera que confeccionar de nuevo la prótesis, Talladium España S.L. repondrá los pilares y tornillos necesarios para rehacer la prótesis, así como los costes derivados de la fabricación de la misma.
Si en caso de haber utilizado nuestros productos y haber cumplido con todas las indicaciones de uso producto, los implantes sufren cualquier daño, TALLADIUM ESPAÑA S.L. se hará cargo el costo de los implantes. Esta cobertura sólo será válida durante los primeros 6 meses después de la colocación de la prótesis realizada con nuestros productos.
REQUISITOS Y PROCEDIMIENTO DE RECLAMACIÓNPara recibir las ventajas indicadas en estos (“TyC”), el clínico debe cumplir los siguientes requisitos: A) La reclamación deberá ser notificada a TALLADIUM ESPAÑA S.L. en el periodo de (30) días desde la fecha en que se detectó el defecto reclamado.B) El clínico o técnico debe comunicar con el departamento de atención al cliente por teléfono o por correo electrónico para hacer la reclamación.C) Se completará un formulario de reclamación junto con un documento o informe que justifique el producto defectuoso. El producto defectuoso, se enviará a las oficinas de TALLADIUM ESPAÑA S.L. dentro delplazo previamente indicado.D) Los clínicos o técnicos que presenten una reclamación de acuerdo con estos (“TyC”) deben estar al día de los pagos a TALLADIUM ESPAÑA S.L. o a cualquiera de sus filiales en el momento en que se presentael formulario de reclamación. E) Todos los procedimientos de uso de nuestros Productos deben realizarse de acuerdo con las instrucciones de TALLADIUM ESPAÑA S.L. y con las prácticas de odontología comúnmente aceptadas.F) Los gastos derivados de este procedimiento serán asumidos por el cliente. Los costes de devolución serán asumidos por TALLADIUM ESPAÑA S.L. En todos los casos que estén cubiertos por estos(“TyC”).
El coste de envío por devolución será asumido por Talladium España S.L. en todos los casos cubiertos por estos (“TyC”).
LIMITACIONES GENERALES DE ESTA GARANTÍAA excepción de la garantía descrita en estos TyC, ni Talladium España S.L., ni sus representantes, ni terceras partes fabricantes o distribuidoras de los Productos, hacen representación u ofrecen garantía, convenio u otro compromiso expreso o implícito, oral o escrito, respecto a los Productos (sin limitación) incluyendo garantías implicadas en la comercialización, durabilidad o idoneidad para usos o propósitos particulares.
Adicionalmente y en la máxima extensión permitida por la ley correspondiente, Talladium España S.L. rechaza (en nombre de sí misma, de sus representantes y de terceras partes fabricantes o distribuidoras de los Productos) cualquier responsabilidad respecto al daño ocasionado directo, indirecto resultante o consecuencia del diseño, composición de la prótesis dental en la que se encuentran integrados los Productos.
EXCLUSIONES DE LA GARANTÍATalladium España S.L limita esta garantía a:- Los pilares una vez transformados formando parte de la prótesis dental. No así a los tornillos utilizados en el anclaje de las mismas.- Los problemas derivados del uso de los tornillos de laboratorio para la fijación final de la prótesis. Talladium España S.L dispone de tornillos clínicos para cumplir esa función.- Los tornillos clínicos que lleven más de 1 año en boca, entendiéndose que el paciente tiene que realizar revisiones anuales con el consiguiente cambio de tornillos.- El fallo se debe al desgaste y uso normal..
MODIFICACIÓN O SUSPENSIÓN DE LA GARANTÍA Talladium España S.L se reserva el derecho a modificar o retirar estos TyC en cualquier momento y sin previo aviso. Cualquier modificación o suspensión no afectará al producto ya instalados en pacientes. Ed
.201
7-01
AV. BLONDEL, 54 3º · 25002 · LLEIDA (SPAIN)TEL. +34 973 289 580