Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0....

24
Solar Dehydrator Sponsored by:

Transcript of Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0....

Page 1: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Solar Dehydrator

Sponsored by:

Page 2: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Advisor and sponsor

•Joseph Greene Ph.D.•Greg Kallio Ph.D.

•Lee Altier Ph.D.,•College of Agriculture

Advisor and Sponsor

Page 3: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Team 1

•William Enos•Mechanical Engineering

Team

•Kris Gilmour•Mechatronic Engineering

Page 4: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Team 2

•Sou Yang•Mechanical Engineering

Team

•Cortlin St. Pierre•Mechanical Engineering

Page 5: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Background

• 25% of produce wasted• Extend product shelf life • Solar convection and resistance heater• California Food Safety Standards

Background

Page 6: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundDesign Changes

Page 7: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Background

• Hybrid Design

Design Solution

Page 8: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Background

• Moisture Resistant Strip Heater• User Interface

– Simple to use

Design Solution

Page 9: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Background

• CFD– Fan locations

CFD Analysis

Page 10: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundDrying Analysis

• Fick’s Second Law of Diffusivity

•Diffusivity Assumption (Fall Rate Drying Period)

Page 11: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundDrying Analysis

• Allowable thickness for 30°C, 0.5 m/s• 5-6 mm

• Drying time for 40°C• 7.5 hours

Page 12: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundDrying Analysis

0

2000

4000

6000

8000

10000

12000

14000

0 0.2 0.4 0.6 0.8 1 1.2

Requ

ired

Wat

ts

Air Velocity [m/s]

Heat vs Air Velocity

40°C TemperatureChange

30°C TemperatureChange

20°C TemperatureChange

• Heater = 1100 [W]• Solar collector box = 1000 [W]

• Target Temperature = 30°C• Target Thickness = 5-6 [mm]

Page 13: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Team 2Frame Fabrication

Page 14: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Completed Fabrication

Page 15: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Design Change

Page 16: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Finished Project

Page 17: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundTesting

•Quantitative Specifications

Specifications Target Actual

Drying Time < 12 Hours < 12 Hours

Temperature Difference Spatially Inside Drying Chamber ±5°F ±5°F

Volumetric Flow Rate of Air 530 CFM 400 CFM

Batch Weight 50 lbs wet weight sliced tomatoes a day

50 lbs/batch

Page 18: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundFinal Budget

$88,566.00

$1,663.18 $2,379.70 $178.12

Engineering CostRaw MaterialPurchased PartsUnused Budget

Page 19: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

BackgroundSponsors

•College of Agriculture•Student Learning Fee

•Carriere Family Farm•Enos Family•Fleming Services•Hiway Truck & Trailer Parts

•Willows, CA

Page 20: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Reflection

● Merits of the design solution○ Efficient heat collector ○ Ample drying capacity○ Horizontal and vertical airflow operation

● Unique problems encountered○ Project transportation

Page 21: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Solutions Achieved

● Axle and hitch implementation● Modular drying cabinet plate● Duct

Page 22: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

Suggestions for the Future

● Non-detachable heat collector● Hitch location moved to the front● Two axles● Weight reduction● Increased airflow● Decreased height of the drying cabinet● Higher output heater● Durable coating● Louver-oriented system for the fans

Page 23: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

ConclusionConclusion

Page 24: Solar Dehydrator · Drying Analysis. Background 0. 2000. 4000. 6000. 8000. 10000. 12000. 14000. 0. 0.2. 0.4. 0.6. 0.8. 1. 1.2. Required Watts. Air Velocity [m/s] Heat vs Air Velocity.

QuestoinsQuestions?