Software Upgrade Procedures BASIL H SeapiX · 2020. 5. 11. · Clonezilla automatically boots (GNU...
Transcript of Software Upgrade Procedures BASIL H SeapiX · 2020. 5. 11. · Clonezilla automatically boots (GNU...
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 1/26
N° GIX-M-FO-QUAL-058D
Software Upgrade Procedures BASIL_H
SeapiX
External approval
Company Name Function Date Visa
Internal approval
Identification Name Function Date Visa
Written by MAR Product Manager 25/06/2019 MAR
Approved by GDU Soft. Engineer 25/06/2019 GDU
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 2/26
N° GIX-M-FO-QUAL-058D
Changes
Edition Date Pages Purpose Written by
A 11/05/2020 All Creation MAR
Table of contents
1 Object .............................................................................................................................................................3
2 Applicable and reference documents ............................................................................................................3
3 Terminology ...................................................................................................................................................3
4 Upgrade Procedures ......................................................................................................................................3
4.1 Important considerations ......................................................................................................................4
4.2 Building the upgrade pack.....................................................................................................................5
4.2.1 Clonezilla bootable drive ..................................................................................................................5
4.2.2 SW key ..............................................................................................................................................7
4.3 BFU upgrade ....................................................................................................................................... 10
4.4 VPU upgrade ...................................................................................................................................... 19
4.4.1 Surface Software Upgrade ............................................................................................................. 19
4.4.2 Chrome Installation ....................................................................................................................... 24
4.4.3 TeamViewer Installation ................................................................................................................ 25
4.5 Upgrade verification ........................................................................................................................... 26
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 3/26
N° GIX-M-FO-QUAL-058D
1 Object
This document is the procedure to follow in order to upgrade SeapiX software from Basil_E version to Basil_H
version. Extreme caution is required to succeed and avoid permanent damage to the system. The upgrade
shall be done by following the below procedures (same order). Before upgrading the system, please contact
iXBlue to check compatibility and receive all the upgrade pack.
2 Applicable and reference documents
3 Terminology
Useful definitions, conventions and acronyms are given here below.
4 Upgrade Procedures
The Basil_H upgrade consists in:
• BFU:
o Debian Linux OS update (Stretch 9.9.0)
o IXV software update (ixv-3.0.h-2139-stretch-amd64)
o New Web GUI software (seapix-web 1.0.14)
o New Record/Replay software (SeaNotify 1.0.2)
• VPU
o Surface Software Update (Setup_SeapiX_V8.6.4.16)
• SAU
o None
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 4/26
N° GIX-M-FO-QUAL-058D
4.1 Important considerations
Before starting the upgrade, make sure:
• That you downloaded:
• Rufus software: https://github.com/pbatard/rufus/releases/download/v3.5/rufus-3.5p.exe
• Clonezilla ISO file: https://osdn.net/frs/redir.php?m=rwthaachen&f=clonezilla%2F71030%2Fclonezilla-live-2.6.1-25-amd64.iso
• Tools:
• TeamViewer Host: https://get.teamviewer.com/seapix
• Chrome offline installer: https://secure.ixblue.com/seapix/Tools/ChromeStandaloneSetup64.exe
• [Basil_H Pack]: The SeapiX Basil_H upgrade package: https://secure.ixblue.com/seapix/
• That you can connect to the BFU
• A screen (with DVI cable)
• A keyboard (preferably USB, QWERTY)
• That you can allocate 2 USB sticks
• [USB_1]: One with at least 4 GB free space.
• [USB_2]: One with at least 500MB capacity (the content of this USB stick will be erased during the process).
If any of these elements is missing, please contact iXBlue and do not try to upgrade the
SeapiX software. Download all the necessary files before starting upgrading the system.
The VPU upgrade can be done remotely using TeamViewer©, do not hesitate to contact
iXBlue to plan the remote assistance.
https://github.com/pbatard/rufus/releases/download/v3.5/rufus-3.5p.exehttps://osdn.net/frs/redir.php?m=rwthaachen&f=clonezilla%2F71030%2Fclonezilla-live-2.6.1-25-amd64.isohttps://osdn.net/frs/redir.php?m=rwthaachen&f=clonezilla%2F71030%2Fclonezilla-live-2.6.1-25-amd64.isohttps://get.teamviewer.com/seapixhttps://secure.ixblue.com/seapix/Tools/ChromeStandaloneSetup64.exehttps://secure.ixblue.com/seapix/
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 5/26
N° GIX-M-FO-QUAL-058D
4.2 Building the upgrade pack
4.2.1 Clonezilla bootable drive
Tools:
• [USB_2]
• Rufus software executable file
• Clonezilla ISO file
Process:
1. Start Rufus software
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 6/26
N° GIX-M-FO-QUAL-058D
2. Connect [USB_2], you should see it appearing in Device
3. Click on Select and choose clonezilla-live-2.6.1-25-amd64.iso you have downloaded and choose
Clonezilla as name of the volume
4. Keep default settings and click on Start
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 7/26
N° GIX-M-FO-QUAL-058D
5. Choose Write ISO image and click on OK
6. Click on OK
7. When it is completed, click on Close
8. You can eject safely the USB stick from the computer, it is ready.
4.2.2 SW key
Tools:
• [USB_1]
• [Basil_H Pack]
Process:
1. Copy into [USB_1]:
a. seaNotifySetup.msi
b. Setup_SeapiX_V8.6.4.16.exe
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 8/26
N° GIX-M-FO-QUAL-058D
c. ChromeStandaloneSetup64.exe
d. TeamViewer_Host_Setup.exe
2. Unzip:
a. BASIL_H-POSEIDON.zip → BASIL_H-POSEIDON
b. BASIL_H-OCEANOS.zip → BASIL_H-OCEANOS
c. BASIL_H-TITAN2.zip → BASIL_H-TITAN2
d. BASIL_H-TITAN.zip → BASIL_H-TITAN
Make sure the unzipped folder is not adding a folder level i.e BASIL_H-xxxx folder shall not
contain BASIL_H-xxxx folder but directly the different files. This is usually managed by
slecting carefully the extraction folder (you can directly extract in your USB drive root
folder)
3. Copy into [USB_1]:
a. BASIL_H-POSEIDON
b. BASIL_H-OCEANOS
c. BASIL_H-TITAN2
d. BASIL_H-TITAN
Expected [USB_1] arborescence is:
https://secure.ixblue.com/seapix/Tools/ChromeStandaloneSetup64.exe
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 9/26
N° GIX-M-FO-QUAL-058D
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 10/26
N° GIX-M-FO-QUAL-058D
4.3 BFU upgrade
Tools:
• [USB_1]
• [USB_2]
• Screen
• Keyboard
Process:
1. Make sure the ITU and BFU are turned off
2. Connect the screen and keyboard into the BFU
3. Connect [USB_2] into the BFU
4. Power on the BFU. Clonezilla automatically boots (GNU GRUB window)
If it doesn’t boot on the Clonezilla drive, restart the BFU and press DEL until you access the
BIOS menu where you can define the boot order (put boot #1 for Clonezilla drive)
If the Clonezilla drive is not recognized, use another USB port from BFU
5. Select Clonezilla live (Default settings, …)
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 11/26
N° GIX-M-FO-QUAL-058D
6. Select en_US.UTF-8 English
7. Select Keep the default keyboard layout
8. Select Start Clonezilla
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 12/26
N° GIX-M-FO-QUAL-058D
9. Select device-image work with disks or partitions using images
10. Select local_dev
11. Connect [USB_1] and wait for 5s
12. Press Enter to continue. Wait until you see [USB_1] name in the list (the name will be the
manufacturer one / not “USB_1”). In our example, this is My_Passport drive.
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 13/26
N° GIX-M-FO-QUAL-058D
If the USB stick is not recognized, try to use another USB port on BFU.
13. Press CTL+C
14. Select the USB stick containing the BFU disk image. You should recognize your USB stick name (still
My_Passport in our example)
15. Do not click on Enter at this stage, highlight / Top_directory_in_the_local_device and press Tab key
until you can select , then press Enter.
16. Press Enter
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 14/26
N° GIX-M-FO-QUAL-058D
17. Select Beginner…
18. Select restoredisk
19. At this stage, make sure you identify your BFU type. There are currently three BFU models which can
be easily identified by looking at the rear plate:
a. TITAN:
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 15/26
N° GIX-M-FO-QUAL-058D
b. TITAN2:
c. OCEANOS:
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 16/26
N° GIX-M-FO-QUAL-058D
d. POSEIDON:
20. Select:
a. EITHER BASIL_H-TITAN if your BFU is TITAN model
b. OR BASIL_H-TITAN2 if your BFU is TITAN2 model
c. OR BASIL_H-OCEANOS if your BFU is OCEANOS model
d. OR BASIL_H-POSEIDON if your BFU is OCEANOS model
21. Select the BFU HDD
22. Select Yes, check the image before restoring
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 17/26
N° GIX-M-FO-QUAL-058D
23. Select -p choose
24. Press Enter to continue
25. In order to confirm the action, type y and press Enter to continue
26. In order to confirm again the action, type y and press Enter to continue
27. Press Enter to continue
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 18/26
N° GIX-M-FO-QUAL-058D
28. Select Poweroff
29. After BFU shutdown, remove [USB_1] and [USB_2]
30. Power on the BFU and check that the screen displays logs similar to [HH:MM:SS]
INFO:f_apply:514:NMEA #1:/dev/ttyS2 is disabled
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 19/26
N° GIX-M-FO-QUAL-058D
4.4 VPU upgrade
4.4.1 Surface Software Upgrade
Tools:
• [USB_1]
Process:
1. Connect [USB_1] into the VPU
2. Stop SeapiX software
3. Open a window explorer and go into C:\IXBLUE\SeapiX directory
4. Backup the Settings, Outputs and Data folders located in the C:\IXBLUE\SeapiX directory
5. Delete C:\IXBLUE\SeapiX\Setting and C:\IXBLUE\SeapiX\Outputs directory
6. Copy the Setup_SeapiX_V8.6.4.16.exe file from [USB_1] in C:\IXBLUE\SeapiX directory
7. Run the Setup_SeapiX_V8.6.4.16.exe file
8. Select your installation language (does not have any effect on the SeapiX software language)
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 20/26
N° GIX-M-FO-QUAL-058D
9. Click on Next
10. Configure the installation folder as C:\IXBLUE\SeapiX\SeapiX_V8.6.4.16 and click on Next
11. Configure
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 21/26
N° GIX-M-FO-QUAL-058D
a. the data folder as C:\IXBLUE\SeapiX\Data
b. the settings folder C:\IXBLUE\SeapiX\SeapiX_V8.6.4.16 \Settings
c. the outputs folder as C:\IXBLUE\SeapiX\SeapiX_V8.6.4.16 \Outputs
d. and click on Next
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 22/26
N° GIX-M-FO-QUAL-058D
12. Enter the ship and station name and click on Next
13. Select SeapiX 3D Sounder and click on Next
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 23/26
N° GIX-M-FO-QUAL-058D
14. Click on Next (allow the creation of a Desktop icon)
15. Click on Install
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 24/26
N° GIX-M-FO-QUAL-058D
16. When the installation is done, do not tick Launch SeapiX and click on Finish
17. Copy the license files (ixblue.lcs and ixblue.lic) from previous GECDIS folder to
C:\IXBLUE\SeapiX\SeapiX_V8.6.4.16 folder
4.4.2 Chrome Installation
We recommend to use Chrome Browser to access the SeapiX web interface (192.168.16.9:8989)
Tools:
• [USB_1]
Process:
1. Connect [USB_1] into the VPU
2. In the C:\IXBLUE\SeapiX\ folder, copy ChromeStandaloneSetup64.exe file from [USB_1]
3. Run the ChromeStandaloneSetup64.exe
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 25/26
N° GIX-M-FO-QUAL-058D
4.4.3 TeamViewer Installation
To enable remote assistance from iXBlue support, a TeamViewer Host module shall be installed on the VPU. If
it is not already the case (TeamViewer Host icon shown in the notification area of Windows OS), please
proceed with the following installation.
Figure 1: TeamViewer already installed
-
SeapiX
Software Upgrade Procedures BASIL_H
N°: SSD-C1392 Edition A
11/05/2020
Industrial confidentiality
This document, together with its contents, is the property of iXBlue. It must not be reproduced, communicated or disclosed to a third party without express written consent.
Page 26/26
N° GIX-M-FO-QUAL-058D
Tools:
• [USB_1]
Process:
4. Connect [USB_1] into the VPU
5. Follow Installation Manual (SSD-C1306A_SeapiX-IM)
4.5 Upgrade verification
Process:
1. Start the BFU and make sure the ITU starts (if not check the command link cable and connection)
2. Start the VPU and run the SeapiX Surface Software
3. If the Start button is blue, you are ready to run BASIL_H software, enjoy!
4. To use SeaNotify, click on SeaNotify icon from VPU desktop