SNI DT-91-0002-2007

22
 Revisi SNI 19-6774-2002 i Kembali Daftar is i Prakata ..................................................................................................................................... ii Daftar isi.....................................................................................................................................i Pendahuluan.............................................................................................................................ii 1 Ruang lingkup .................................................................................................................. 1 2 Acuan normatif............... .................................................................................................. 1 3 Istilah dan definisi ............................................................................................................ 1 4 Persyaratan ..................................................................................................................... 3 5 Kriteria kualitas air baku dan pompa air baku.................................................................. 3 6 Kapasitas, unit operasi dan proses.................................................................................. 4 7 Kriteria perencanaan unit paket....... ................................................................................ 4 8 Catu daya ...................................................................................................................... 10 9 Kriteria struktur bangunan ............................................................................................. 11 10 Rencana tapak dan sarana pelengkap. ......................................................................... 11 11 Dokumen perencana an ................................................................................................. 12 12 Persyaratan untuk perencana...................................... .................................................. 12 Lampiran A ............................................................................................................................ 13 Lampiran B ............................................................................................................................ 14 Lampiran C ............................................................................................................................ 15 Lampiran D ............................................................................................................................ 18 Bibliografi ............................................................................................................................... 19

Transcript of SNI DT-91-0002-2007

Page 1: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 122

Revisi SNI 19-6774-2002

iKembali

Daftar isi

Prakata ii

Daftar isiiPendahuluanii

1 Ruang lingkup 1

2 Acuan normatif 1

3 Istilah dan definisi 1

4 Persyaratan 3

5 Kriteria kualitas air baku dan pompa air baku 3

6 Kapasitas unit operasi dan proses 4

7 Kriteria perencanaan unit paket 4

8 Catu daya 10

9 Kriteria struktur bangunan 1110 Rencana tapak dan sarana pelengkap 11

11 Dokumen perencanaan 12

12 Persyaratan untuk perencana 12

Lampiran A 13

Lampiran B 14

Lampiran C 15

Lampiran D 18

Bibliografi 19

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 222

Revisi SNI 19-6774-2002

iiKembali

Prakata

Tata cara perencanaan unit paket instalasi pengolahan air merupakan revisi dari SNI 19-

6774-2002 Tata cara perencanaan unit paket instalasi penjernihan air dan disusun kembalidengan penambahan hasil-hasil penelitian di dalam negeri yang telah digunakan olehmasyarakat secara luas

Tata cara perencanaan unit paket instalasi pengolahan air ini disusun oleh Panitia TeknikBahan Konstruksi Bangunan dan Rekayasa Sipil melalui Gugus Kerja LingkunganPermukiman pada Sub Panitia Teknis Perumahan Sarana dan Prasarana LingkunganPermukiman

Tata cara penulisan disusun mengikuti Pedoman BSN Nomor 8 Tahun 2000 dan dibahasdalam forum konsensus yang diselenggarakan pada tanggal 30 November 2006 olehSubpanitia Teknis yang melibatkan para nara sumber pakar dan lembaga terkait

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 322

Revisi SNI 19-6774-2002

iiiKembali

Pendahuluan

Standar ini merupakan kaji ulang serta revisi kedua SNI 19-6774-2002 Tata cara

perencanaan unit paket instalasi pengolahan air yang selama ini telah dijadikan sebagairujukan dalam penilaian proses sertifikasi sistem Unit IPA yang dibuat oleh produsen

Adapun perubahan dan atau penambahannya antara lain

bull Kriteria perencanaan unit flotasi

bull Perencanaan tapak

bull Istilah dan definisi Antara lain untuk air baku dan air minum yang mengacu pada PP 16tahun 2005

Sistem Unit IPA ini telah banyak digunakan oleh Pemerintah maupun badan-badan usahadalam proyek-proyek penyediaan air minum Sehingga dengan adanya standar ini akanmemberikan kemudahan bagi perencana dan jaminan mutu bagi para produsen penggunadan pengelola Unit Paket IPA

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 422

Revisi SNI 19-6774-2002

1 dari 19Kembali

Tata cara perencanaan unit paket instalasi pengolahan air

1 Ruang lingkup

Standar ini mencakup ketentuan-ketentuan mengenai kriteria perencanaan air bakukapasitas instalasi unit operasi struktur dan bahan serta cara pengerjaan dalammerencanakan unit paket instalasi pengolahan air agar diperoleh unit IPA yang optimaldengan kapasitas maksimum 50 Ldetik

2 Acuan normatif

SNI 19ndash6773ndash2002 Spesifikasi intalasi pengolahan air

3 Istilah dan definisi

31

air baku

untuk air minum yang selanjutnya disebut air baku adalah air yang berasal dari sumber air permukaan cekungan air tanah dan atau air hujan yang memenuhi ketentuan baku mututertentu sebagai air baku untuk air minum

32

air minum

adalah air minum rumah tangga yang melalui proses pengolahan atau tanpa prosespengolahan yang memenuhi syarat kesehatan dan dapat langsung diminum

33back wash

sistem pencucian media filter dengan aliran air yang berlawanan arah dengan aliran air padasaat penyaringan

34

beban pelimpah

debit air yang diolah persatuan panjang pelimpah dalam bak pengendap

35

beban permukaan

debit air yang diolah persatuan luas permukaan

36

clarifier

gabungan pengaduk lambat (flokulator) dan pengendap

37

desinfeksi

proses pembubuhan bahan kimia untuk mengurangi zat organik pada air baku danmematikan kumanorganisme

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 522

Revisi SNI 19-6774-2002

2 dari 19Kembali

38

desinfektan

bahan (kimia) yang digunakan untuk mematikan bakteri pathogen dan memperlambatpertumbuhan lumut

39ekspansi

penambahan panjang lapisan media berbutirpenyaring (Le) yang terangkat ke atas padawaktu pencucian media karena penambahan tekanan

310

filtrasi

proses memisahkan padatan dari supernatran melalui media penyaring

311

flok

gumpalan lumpur yang dihasilkan dari proses koagulasi dan flokulasi

312

flokulasi

proses pembentukan partikel flok yang besar dan padat agar dapat diendapkan

313

flotasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan caradiapungkan

314

kapasitas produksivolume air hasil olahan persatuan waktu

315

koagulan

bahan (kimia) yang digunakan untuk pembentukan flok pada proses pencampuran

316

koagulasi

proses pencampuran bahan kimia (koagulan) dengan air baku sehingga membentukcampuran yang homogen

317

manifold

pipa utama yang dipasang pada dasar saringan pasir sebagai pipa pipa air masuk

318

netralisan

bahan kimia yang digunakan untuk menyesuaikan derajat keasaman (pH) pada suatu prosestertentu

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 2: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 222

Revisi SNI 19-6774-2002

iiKembali

Prakata

Tata cara perencanaan unit paket instalasi pengolahan air merupakan revisi dari SNI 19-

6774-2002 Tata cara perencanaan unit paket instalasi penjernihan air dan disusun kembalidengan penambahan hasil-hasil penelitian di dalam negeri yang telah digunakan olehmasyarakat secara luas

Tata cara perencanaan unit paket instalasi pengolahan air ini disusun oleh Panitia TeknikBahan Konstruksi Bangunan dan Rekayasa Sipil melalui Gugus Kerja LingkunganPermukiman pada Sub Panitia Teknis Perumahan Sarana dan Prasarana LingkunganPermukiman

Tata cara penulisan disusun mengikuti Pedoman BSN Nomor 8 Tahun 2000 dan dibahasdalam forum konsensus yang diselenggarakan pada tanggal 30 November 2006 olehSubpanitia Teknis yang melibatkan para nara sumber pakar dan lembaga terkait

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 322

Revisi SNI 19-6774-2002

iiiKembali

Pendahuluan

Standar ini merupakan kaji ulang serta revisi kedua SNI 19-6774-2002 Tata cara

perencanaan unit paket instalasi pengolahan air yang selama ini telah dijadikan sebagairujukan dalam penilaian proses sertifikasi sistem Unit IPA yang dibuat oleh produsen

Adapun perubahan dan atau penambahannya antara lain

bull Kriteria perencanaan unit flotasi

bull Perencanaan tapak

bull Istilah dan definisi Antara lain untuk air baku dan air minum yang mengacu pada PP 16tahun 2005

Sistem Unit IPA ini telah banyak digunakan oleh Pemerintah maupun badan-badan usahadalam proyek-proyek penyediaan air minum Sehingga dengan adanya standar ini akanmemberikan kemudahan bagi perencana dan jaminan mutu bagi para produsen penggunadan pengelola Unit Paket IPA

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 422

Revisi SNI 19-6774-2002

1 dari 19Kembali

Tata cara perencanaan unit paket instalasi pengolahan air

1 Ruang lingkup

Standar ini mencakup ketentuan-ketentuan mengenai kriteria perencanaan air bakukapasitas instalasi unit operasi struktur dan bahan serta cara pengerjaan dalammerencanakan unit paket instalasi pengolahan air agar diperoleh unit IPA yang optimaldengan kapasitas maksimum 50 Ldetik

2 Acuan normatif

SNI 19ndash6773ndash2002 Spesifikasi intalasi pengolahan air

3 Istilah dan definisi

31

air baku

untuk air minum yang selanjutnya disebut air baku adalah air yang berasal dari sumber air permukaan cekungan air tanah dan atau air hujan yang memenuhi ketentuan baku mututertentu sebagai air baku untuk air minum

32

air minum

adalah air minum rumah tangga yang melalui proses pengolahan atau tanpa prosespengolahan yang memenuhi syarat kesehatan dan dapat langsung diminum

33back wash

sistem pencucian media filter dengan aliran air yang berlawanan arah dengan aliran air padasaat penyaringan

34

beban pelimpah

debit air yang diolah persatuan panjang pelimpah dalam bak pengendap

35

beban permukaan

debit air yang diolah persatuan luas permukaan

36

clarifier

gabungan pengaduk lambat (flokulator) dan pengendap

37

desinfeksi

proses pembubuhan bahan kimia untuk mengurangi zat organik pada air baku danmematikan kumanorganisme

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 522

Revisi SNI 19-6774-2002

2 dari 19Kembali

38

desinfektan

bahan (kimia) yang digunakan untuk mematikan bakteri pathogen dan memperlambatpertumbuhan lumut

39ekspansi

penambahan panjang lapisan media berbutirpenyaring (Le) yang terangkat ke atas padawaktu pencucian media karena penambahan tekanan

310

filtrasi

proses memisahkan padatan dari supernatran melalui media penyaring

311

flok

gumpalan lumpur yang dihasilkan dari proses koagulasi dan flokulasi

312

flokulasi

proses pembentukan partikel flok yang besar dan padat agar dapat diendapkan

313

flotasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan caradiapungkan

314

kapasitas produksivolume air hasil olahan persatuan waktu

315

koagulan

bahan (kimia) yang digunakan untuk pembentukan flok pada proses pencampuran

316

koagulasi

proses pencampuran bahan kimia (koagulan) dengan air baku sehingga membentukcampuran yang homogen

317

manifold

pipa utama yang dipasang pada dasar saringan pasir sebagai pipa pipa air masuk

318

netralisan

bahan kimia yang digunakan untuk menyesuaikan derajat keasaman (pH) pada suatu prosestertentu

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 3: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 322

Revisi SNI 19-6774-2002

iiiKembali

Pendahuluan

Standar ini merupakan kaji ulang serta revisi kedua SNI 19-6774-2002 Tata cara

perencanaan unit paket instalasi pengolahan air yang selama ini telah dijadikan sebagairujukan dalam penilaian proses sertifikasi sistem Unit IPA yang dibuat oleh produsen

Adapun perubahan dan atau penambahannya antara lain

bull Kriteria perencanaan unit flotasi

bull Perencanaan tapak

bull Istilah dan definisi Antara lain untuk air baku dan air minum yang mengacu pada PP 16tahun 2005

Sistem Unit IPA ini telah banyak digunakan oleh Pemerintah maupun badan-badan usahadalam proyek-proyek penyediaan air minum Sehingga dengan adanya standar ini akanmemberikan kemudahan bagi perencana dan jaminan mutu bagi para produsen penggunadan pengelola Unit Paket IPA

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 422

Revisi SNI 19-6774-2002

1 dari 19Kembali

Tata cara perencanaan unit paket instalasi pengolahan air

1 Ruang lingkup

Standar ini mencakup ketentuan-ketentuan mengenai kriteria perencanaan air bakukapasitas instalasi unit operasi struktur dan bahan serta cara pengerjaan dalammerencanakan unit paket instalasi pengolahan air agar diperoleh unit IPA yang optimaldengan kapasitas maksimum 50 Ldetik

2 Acuan normatif

SNI 19ndash6773ndash2002 Spesifikasi intalasi pengolahan air

3 Istilah dan definisi

31

air baku

untuk air minum yang selanjutnya disebut air baku adalah air yang berasal dari sumber air permukaan cekungan air tanah dan atau air hujan yang memenuhi ketentuan baku mututertentu sebagai air baku untuk air minum

32

air minum

adalah air minum rumah tangga yang melalui proses pengolahan atau tanpa prosespengolahan yang memenuhi syarat kesehatan dan dapat langsung diminum

33back wash

sistem pencucian media filter dengan aliran air yang berlawanan arah dengan aliran air padasaat penyaringan

34

beban pelimpah

debit air yang diolah persatuan panjang pelimpah dalam bak pengendap

35

beban permukaan

debit air yang diolah persatuan luas permukaan

36

clarifier

gabungan pengaduk lambat (flokulator) dan pengendap

37

desinfeksi

proses pembubuhan bahan kimia untuk mengurangi zat organik pada air baku danmematikan kumanorganisme

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 522

Revisi SNI 19-6774-2002

2 dari 19Kembali

38

desinfektan

bahan (kimia) yang digunakan untuk mematikan bakteri pathogen dan memperlambatpertumbuhan lumut

39ekspansi

penambahan panjang lapisan media berbutirpenyaring (Le) yang terangkat ke atas padawaktu pencucian media karena penambahan tekanan

310

filtrasi

proses memisahkan padatan dari supernatran melalui media penyaring

311

flok

gumpalan lumpur yang dihasilkan dari proses koagulasi dan flokulasi

312

flokulasi

proses pembentukan partikel flok yang besar dan padat agar dapat diendapkan

313

flotasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan caradiapungkan

314

kapasitas produksivolume air hasil olahan persatuan waktu

315

koagulan

bahan (kimia) yang digunakan untuk pembentukan flok pada proses pencampuran

316

koagulasi

proses pencampuran bahan kimia (koagulan) dengan air baku sehingga membentukcampuran yang homogen

317

manifold

pipa utama yang dipasang pada dasar saringan pasir sebagai pipa pipa air masuk

318

netralisan

bahan kimia yang digunakan untuk menyesuaikan derajat keasaman (pH) pada suatu prosestertentu

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 4: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 422

Revisi SNI 19-6774-2002

1 dari 19Kembali

Tata cara perencanaan unit paket instalasi pengolahan air

1 Ruang lingkup

Standar ini mencakup ketentuan-ketentuan mengenai kriteria perencanaan air bakukapasitas instalasi unit operasi struktur dan bahan serta cara pengerjaan dalammerencanakan unit paket instalasi pengolahan air agar diperoleh unit IPA yang optimaldengan kapasitas maksimum 50 Ldetik

2 Acuan normatif

SNI 19ndash6773ndash2002 Spesifikasi intalasi pengolahan air

3 Istilah dan definisi

31

air baku

untuk air minum yang selanjutnya disebut air baku adalah air yang berasal dari sumber air permukaan cekungan air tanah dan atau air hujan yang memenuhi ketentuan baku mututertentu sebagai air baku untuk air minum

32

air minum

adalah air minum rumah tangga yang melalui proses pengolahan atau tanpa prosespengolahan yang memenuhi syarat kesehatan dan dapat langsung diminum

33back wash

sistem pencucian media filter dengan aliran air yang berlawanan arah dengan aliran air padasaat penyaringan

34

beban pelimpah

debit air yang diolah persatuan panjang pelimpah dalam bak pengendap

35

beban permukaan

debit air yang diolah persatuan luas permukaan

36

clarifier

gabungan pengaduk lambat (flokulator) dan pengendap

37

desinfeksi

proses pembubuhan bahan kimia untuk mengurangi zat organik pada air baku danmematikan kumanorganisme

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 522

Revisi SNI 19-6774-2002

2 dari 19Kembali

38

desinfektan

bahan (kimia) yang digunakan untuk mematikan bakteri pathogen dan memperlambatpertumbuhan lumut

39ekspansi

penambahan panjang lapisan media berbutirpenyaring (Le) yang terangkat ke atas padawaktu pencucian media karena penambahan tekanan

310

filtrasi

proses memisahkan padatan dari supernatran melalui media penyaring

311

flok

gumpalan lumpur yang dihasilkan dari proses koagulasi dan flokulasi

312

flokulasi

proses pembentukan partikel flok yang besar dan padat agar dapat diendapkan

313

flotasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan caradiapungkan

314

kapasitas produksivolume air hasil olahan persatuan waktu

315

koagulan

bahan (kimia) yang digunakan untuk pembentukan flok pada proses pencampuran

316

koagulasi

proses pencampuran bahan kimia (koagulan) dengan air baku sehingga membentukcampuran yang homogen

317

manifold

pipa utama yang dipasang pada dasar saringan pasir sebagai pipa pipa air masuk

318

netralisan

bahan kimia yang digunakan untuk menyesuaikan derajat keasaman (pH) pada suatu prosestertentu

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 5: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 522

Revisi SNI 19-6774-2002

2 dari 19Kembali

38

desinfektan

bahan (kimia) yang digunakan untuk mematikan bakteri pathogen dan memperlambatpertumbuhan lumut

39ekspansi

penambahan panjang lapisan media berbutirpenyaring (Le) yang terangkat ke atas padawaktu pencucian media karena penambahan tekanan

310

filtrasi

proses memisahkan padatan dari supernatran melalui media penyaring

311

flok

gumpalan lumpur yang dihasilkan dari proses koagulasi dan flokulasi

312

flokulasi

proses pembentukan partikel flok yang besar dan padat agar dapat diendapkan

313

flotasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan caradiapungkan

314

kapasitas produksivolume air hasil olahan persatuan waktu

315

koagulan

bahan (kimia) yang digunakan untuk pembentukan flok pada proses pencampuran

316

koagulasi

proses pencampuran bahan kimia (koagulan) dengan air baku sehingga membentukcampuran yang homogen

317

manifold

pipa utama yang dipasang pada dasar saringan pasir sebagai pipa pipa air masuk

318

netralisan

bahan kimia yang digunakan untuk menyesuaikan derajat keasaman (pH) pada suatu prosestertentu

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 6: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 622

Revisi SNI 19-6774-2002

3 dari 19Kembali

319

netralisasi

proses untuk menyesuaikan derajat keasaman (pH) pada air

320

nilai gradien kecepatan Glaju penurunan kecepatan persatuan waktu (detik)

321

nozzle

perlengkapan yang dipasang pada dasar saringan pasir untuk meratakan aliran air

322

sedimentasi

proses pemisahan padatan dan air berdasarkan perbedaan berat jenis dengan carapengendapan

323

surface wash

sistem pencucian dengan menyemprotkan air pada permukaan media saringan

324

unit paket instalasi pengolahan air

unit paket instalasi pengolahan air yang selanjutnya disebut unit paket IPA adalah unit paketyang dapat mengolah air baku melalui proses fisik kimia dan atau biologi tertentu dalambentuk yang kompak sehingga menghasilkan air minum yang memenuhi baku mutu yangberlaku didesain dan dibuat pada suatu tempat yang selanjutnya dapat dirakit di tempat laindan dipindahkan yang terbuat dari bahan plat baja dan plastik atau fiber

325

waktu tinggal td

waktu yang diperlukan oleh air selama proses tertentu berlangsung

4 Persyaratan

Perencanaan dan produk unit paket IPA harus mendapat sertifikat dari instansilembagayang berwenang

5 Kriteria kualitas air baku dan pompa air baku

51 Kualitas air baku

Air baku yang dapat diolah dengan Unit Paket IPA harus memenuhi ketentuan baku mutuyang berlaku

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 7: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 722

Revisi SNI 19-6774-2002

4 dari 19Kembali

52 Pompa air baku

a) Kriteria kapasitas dan cadangan pompa air baku harus memenuhi ketentuan berikut 1) kapasitas pompa air baku (10ndash20) lebih besar dan kapasitas rencana unit paket

IPA2) pompa cadangan minimal 1buah3) masing-masing pompa cadangan harus mempunyai jenis tipe dan kapasitas yang

sama

b) Jenis dan tipe pompa air baku yaitu1) Jenis sentrifugal dari jenis aliran axial atau aliran campuran tipe tidak mudah

tersumbat (non clogging ) dengan ketentuan sebagai berikut(a) Memperhitungkan jarak dari sumbu pompa terhadap muka air terendah harus

lebih kecil dari NPSH yang tersedia (net positif suction head)(b) Pompa air baku sampai tekanan 30 m harus mempunyai impeller tunggal (single

stage )(c) Tumpuan putaran pompa menggunakan pelumas

2) Jenis pompa benam (submersible pump ) dengan persyaratan

(a) dilengkapi dengan sistem guiding bar dan pipa untuk discharge lengkap denganfitting dan bend 90ordm medium untuk sambungan ke pipa tranmisi air baku(b) menyediakan kabel khusus pompa benam yang sesuai dengan uluran dan daya

motor pompa terpasang Bila memerlukan penyambungan dalam air harus diberiisolasi khusus

(c) dilakukan pengamanan pompa sekurang-kurangnya pengamanan terhadapkelembaban ruang dalam pompa dan suhu tinggi

6 Kapasitas unit operasi dan proses

61 Kapasitas

Kapasitas unit paket IPA harus memiliki besaran debit (1 - 50) Literdetik

62 Unit operasi dan proses

Unit operasi dan proses per unit paket IPA dapat berupaa) Unit operasi dan proses koagulasib) Unit operasi dan proses flokulasic) Unit operasi dan proses flotasid) Unit operasi dan proses sedimentasie) Unit operasi filtrasif) Unit proses desinfeksi

7 Kriteria perencanaan unit paket

71 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Kriteria perencanaan untuk Unit koagulasi (pengaduk cepat) dapat dilihat pada Tabel 1berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 8: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 822

Revisi SNI 19-6774-2002

5 dari 19Kembali

Tabel 1 Kriteria perencanaan unit koagulasi (pengaduk cepat)

Unit Kriteria

Pengaduk cepat

bull Tipe Hidrolis- terjunan- saluran bersekat- dalam pipa bersekat- Perubahan phasa pengaliran(NRe)

Mekanis- Bilah (Blade) pedal (padle) Kipas- Flotasi

bull Waktu pengadukan (detik) 30 ndash 120

bull Nilai Gdetik gt 750

7 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

Kriteria perencanaan untuk unit flokulasi (pengaduk lambat) dapat dilihat pada Tabel 2berikut

Tabel 2 Kriteria perencanaan unit flokulasi (pengaduk lambat)

FLOKULATOR MEKANIS

KRITERIA UMUMFLOKULATOR

HIDROLISsumbu

horizontaldengan pedal

sumbu

vertikaldengan bilah

FLOKULATORCLARIFIER

G (gradien kecapatan) 1detik60 (menurun) ndash

560 (menurun)

ndash 1070 (menurun)

ndash 10100 ndash 10

Waktu kontak (menit) 30 ndash 45 30 ndash 40 20 ndash 40 20 ndash 100

Tahap flokulasi(buah) 6 ndash 10 3 ndash 6 2 ndash 4 1

Pengendalian energiBukaan pintu

sekatKecepatan

putaranKecepatan

putaranKecepatanaliran air

Kecepatan aliran max(mdet) 09 09 18 ndash 27 15 ndash 05

Luas bilahpedal dibandingkanluas bak ()

-- 5 ndash 20 01 ndash 02 -

Kecepatan perputaran sumbu

(rpm)-- 1 ndash 5 8 ndash 25 -

Tinggi (m) 2 ndash 4

Keterangan termasuk ruang sludge blanket

7 3 Kriteria perencanaan unit flotasi (pengapungan)

Kriteria perencanaan untuk unit flotasi (pengapungan) dapat dilihat pada Tabel 3 berikut

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 9: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 922

Revisi SNI 19-6774-2002

6 dari 19Kembali

Tabel 3 Kriteria perencanaan unit flotasi (pengapungan)

PROSESALIRANUDARA

(NLm3

air)

UKURANGELEMBUNG

(mm)

INPUTTENAGA

(Watt jamm3)

WAKTUDETENSI(menit)

BEBANHIDROLIK

PERMUKAAN(mjam)

Flotasi untukpemisahan

lemak100 ndash 400 2 ndash 5 5 ndash 10 5 ndash 15 10 ndash 30

Flotasimekanik

10000 02 ndash 2 60 ndash 120 4 ndash 16 -

Flotasikelarutan

udara15 ndash 50 40 ndash 70 μm 40 ndash 80

20 ndash 40bersamaan

denganflokulasi

3 ndash 10

7 4 Kriteria perencanaan unit sedimentasi (pengendap)

Kriteria perencanaan untuk unit sedimentasi (Pengendap) dapat dilihat pada Tabel 4 berikut

Tabel 4 Kriteria unit sedimentasi (bak pengendap)

KRITERIA UMUMBAK PERSEGI

(aliranhorizontal)

BAK PERSEGIALIRAN VERTIKAL

(menggunakanpelattabungpengendap)

BAKBUNDAR ndash

(aliranvertikal ndash

radial)

BAKBUNDAR ndash

(kontakpadatan)

CLARIFIER

Beban permukaan(m

3m

2jam)

08 ndash 25 38 ndash 75) 13 ndash 19 2 ndash 305 ndash 15

Kedalaman (m) 3 ndash 6 3 ndash 6 3 ndash 5 3 ndash 6 05 ndash 10

Waktu retensi (jam) 1 5 ndash 3 007) 1 ndash 3 1 ndash 2 2 ndash 25

Lebar panjang gt 15 - - - -

Beban pelimpah(m

3mjam)

lt 11 lt 11 38 ndash 15 7 ndash 1572 ndash 10

Bilangan Reynold lt 2000 lt 2000 - - lt 2000

Kecepatan padapelattabungpengendap(mmenit)

- max 015 - - -

Bilangan Froude gt 10-5

gt 10-5

- - gt 10-5

Kecepatan vertikal(cmmenit)

- - - lt 1 lt 1

Sirkulasi Lumpur - - -3 ndash 5 dari

input-

Kemiringan dasar bak (tanpa scraper)

45o ndash 60

o45

o ndash 60

o45

o ndash 60

ogt 60

o45

o ndash 60

o

Periode antar pengurasan lumpur (jam)

12 ndash 24 8 ndash 24 12 ndash 24 Kontinyu 12 ndash 24

Kemiringantubeplate

30o 60

o30

o 60

o30

o60

o30

o60

o

30o60

o

Catatan ) luas bak yang tertutupi oleh pelattabung pengendap) waktu retensi pada pelattabung pengendap

) pembuangan lumpur sebagian

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 10: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1022

Revisi SNI 19-6774-2002

7 dari 19Kembali

7 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Kriteria Perencanaan untuk Unit Filtrasi (Saringan Cepat) dapat dilihat pada Tabel 5 berikut

Tabel 5 Kriteria perencanaan unit filtrasi (saringan cepat)

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan1 Jumlah bak saringan N = 12 Q

05) minimum 5 bak -

2 Kecepatan penyaringan(mjam)

6 ndash 11 6 ndash 11 12 ndash 33

3 Pencucian

bull Sistem pencucian Tanpadenganblower amp atausurface wash

Tanpadengan blower ampatau surface wash

Tanpadenganblower amp atausurface wash

bull Kecepatan (mjam) 36 ndash 50 36 ndash 50 72 ndash 198

bull lama pencucian

(menit)

10 ndash 15 10 ndash 15 -

bull periode antara duapencucian (jam)

18 ndash 24 18 ndash 24 -

bull ekspansi () 30 ndash 50 30 ndash 50 30 ndash 50

4 Media pasir

bull tebal (mm) 300 ndash 700 300 ndash 700 300 ndash 700

bull singel media 600 ndash 700 600 ndash 700 600 ndash 700

bull media ganda 300 -600 300 ndash 600 300 -600

bull Ukuran efektifES(mm)

03 ndash 07 03 ndash 07 -

bull Koefisienkeseragaman UC

12 ndash 14 12 ndash 14 12 ndash 14

bull Berat jenis (kgdm3) 25 ndash 265 25 ndash 265 25 ndash 265

bull Porositas 04 04 04

bull Kadar SiO2 gt 95 gt 95 gt 95

5 Media antransit

bull tebal (mm) 400 ndash 500 400 ndash 500 400 ndash 500

bull ES (mm) 12 ndash 18 12 ndash 18 12 ndash 18

bull UC 15 15 15

bull berat jenis (kgdm3) 135 135 135

bull porositas 05 05 05

6 Filter botomdasar saringan 1)Lapisan penyanggadari atas ke bawah

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 2 ndash 5 2 ndash 5 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 5 ndash 10 5 ndash 10 -

bull Kedalaman (mm) 80 ndash 100 80 ndash 100 -Ukuran butir (mm) 10 ndash 15 10 ndash 15 -

bull Kedalaman (mm) 80 ndash 150 80 ndash 150 -Ukuran butir (mm) 15 ndash 30 15 ndash 30 -

2)Filter Nozel

bull Lebar Slotnozel (mm)

lt 05 lt 05 lt 05

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 11: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1122

Revisi SNI 19-6774-2002

8 dari 19Kembali

Tabel 5 Lanjutan

Jenis SaringanNO UNIT Saringan Biasa

(Gravitasi)Saringan dg Pencucian

Antar SaringanSaringan

Bertekanan

bull Prosentaseluas slot nozelterhadap luasfilter ()

gt 4 gt 4 gt 4

Catatan ) untuk saringan dengan jenis kecepatan menurun) untuk saringan dengan jenis kecepatan konstan (constan filtration rate ) harusdilengkapi dengan pengatur aliran (flow controller ) otomatis

7 6 Kriteria perencanaan pembubuhan bahan kimia

761 Koagulan

7611 Kriteria koagulan

a) Jenis koagulan yang digunakan1) aluminium sulfat Al2(SO4)3 l4(H2O) diturunkan dalam bentuk cair konsentrasi sebesar

(5 mdash 20) untuk instalasi dengan kapasitas lebih kecil dari 20 Ldetil dankonsentrasi larutan sampai dengan 20 untuk instalasi lebih besar dari 20 Ldetik

2) PAC Poly Aluminium Chloride (Al10(OH)15Cl15) Kualitas PAC ditentukan oleh kadar aluminium oxide (Al2O3) yang terkait sebagai PAC dengan kadar (10 mdash 11)

b) Dosis koagulan ditentukan berdasarkan hasil percobaan jar test terhadap air baku c) Pembubuhan koagualan ke pengaduk cepat dapat dilakukan secara gravitasi atau

pemompaan

7612 Bak koagulan

a) Bak koagulan harus dapat menampung larutan selama 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1 buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap bahan koagulan

762 Netralisan

7621 Kriteria netralisan

a) Harus berupa bahan alkalin1) kapur (CaO) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 202) soda abu (Na2CO3) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan 5

sampai dengan 203) soda api (NaOH) dibubuhkan dalam bentuk larutan dengan konsentrasi larutan

maksimum 20b) Dosis bahan alkalin ditentukan berdasarkan percobaanc) Pembubuhan bahan alkalin secara gravitasi atau pernompaan dibubuhkan sebelum dan

atau sesudah pembubuhan koagulan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 12: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1222

Revisi SNI 19-6774-2002

9 dari 19Kembali

7622 Bak netralisan

a) Bak dapat menampung larutan selama 8 sampa dengan 24 jamb) Diperlukan 2 buah bak yaitu 1 buah bak pengaduk manual atau mekanis dan 1buah bak

pembubuhc) Bak harus dilindungi dari pengaruh luar dan tahan terhadap beban alkalin

763 Desinfektan

7631 Kriteria desinfektan

a) Jenis densifektan yang digunakan1) gas klor (Cl2) kandungan Klor aktif minimal 992) kaporit atau kalsium hipoklorit (CaOCl2 ) x H2O kandungan Klor aktif (60 mdash 70) 3) sodium hipoklorit (NaOCl) kandungan Klor aktif 15

b) Dosis klor ditentukan berdasarkan DPC yaitu jumlah Klor yang dikonsumsi air besarnyatergantung dari kualitas air bersih yang di produksi serta ditentukan dari sisa Klor diinstalasi (025 ndash 035) mgL

7632 Pembubuhan desinfektan

a) Gas Klor disuntikan langsung ke pipa air bersih pembubuhan gas menggunakanperalatan tertentu yang memenuhi ketentuan yang berlaku

b) Kaporit atau sodium hipoklorit dibubuhkan ke pipa air bersih secara gravitasi ataumekanis

7633 Keperluan perlengkapan desinfeksi

a) Pembubuhan gas Klor 1) peralatan gas Klor disesuaikan minimal 2 lengkap dengan tabungnya2) tabung gas Klor harus ditempatkan pada ruang khusus yang tertutup

3) ruangan gas Klor harus terdapat peralatan pengamanan terhadap kebocoran gasKlor

4) Alat pengamanan adalah pendeteksi kebocoran gas Klor dan sprinkler air otomatikatau manual

5) harus disediakan masker gas pada ruangan gas Klor

b) Bak kaporit1) bak dapat menampung larutan selama 8 sampai dengan 24 jam2) diperlukan 2 buah bak yaitu bak pengaduk manualmekanis dan bak pembubuh

c) Bak harus dilindungi dari pengaruh luar dan tahan terhadap kaporit

764 Pompa pembubuh dan motor pengaduk

Jumlah pompa pembubuh larutan kimia dan motor pengaduk unit koagulasi maupun flokulasipaket IPA minimal 2 buah berkapasitas sama

7 7 Kriteria bak penampung air minum

Bak penampung air minum diberi sekat-sekat yang dilengkapi dengana) Ventilasib) Tanggac) Pelimpah air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 13: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1322

Revisi SNI 19-6774-2002

10 dari 19Kembali

d) Lubang pemeriksaan dan perbaikane) Alat ukur ketinggian airf) Pipa penguras

78 Kriteria perencanaan perlengkapan unit paket IPA

Kriteria perencanaan untuk perlengkapan unit paket IPA dapat dilihat pada Tabel 5 berikut

Tabel 6 Kriteria perencanaan perlengkapan unit IPA

No UNIT KRITERIA KETERANGAN

1 Alat Ukur debit () 2 ndash 5 Akurasi alat2 Bak penampung air minum - -

- Waktu tinggal (menit) lt 30 -3 Alat pembubuh Gravitasi danatau pompa -4 Penguras bak sedimentasi Gravitasi atau pompa -5 Pengolahan lumpur Bak pengendapan lumpur (drying bed)

dan filter press -

6 Pengendalian suhu cahayamatahari

Bangunan pelindungshelter

8 Catu daya

81 Penyediaan daya listrik

Penyediaan daya listrik terdapat 2 sumber yaltua) PLNb) Genset

Pemilihan sumber daya sesuai Tabel 7 berikut ini

Tabel 7 Alternatif pemilihan sumber daya listrik

Gambaran situasi lapangan Alternatif pemilihan

Ada jaringan distribusi PLN dengan jarak yangmenguntungkan dari unit dan masih mencukupipermintaan daya serta sesuai dengan direncanakan

Gabungan pelayanan PLN dan 1 unit gensetsebagai cadangan

Tidak ada jaringan distribusi atau tidak ada rencanaperluasan jaringan PLN dalam waktu dekat

2 unit genset dimana 1unit sebagaicadangan

82 Penyediaan bahan bakar

Penyediaan bahan bakar harus memenuh kebutuhan operasi harian dan bulananPenempatan tangki bahan bakar harus daam rumah genset dan bakar harus dapat mengalir secara gravitasiTangki bahan bakar bulanan boleh ditempatkan di bawah atau di permukaan tanah dandapat dilengkapi dengan pompa agar dapat mengalirkan bahan bakar ke tangki harian

83 Kriteria panel

Diesel generator pompa air baku pompa pembubuh pengaduk cepat dan lambat harusdilengkapi panel yang sesuai kebutuhan

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 14: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1422

Revisi SNI 19-6774-2002

11 dari 19Kembali

9 Kriteria struktur bangunan

91 Jenis bangunan

Jenis Bangunan yang diperlukan adalaha) Bangunan IPAb) Bangunan penunjang IPA

1) ruang pembubuh2) ruang jaga3) ruang pompa ruang genset4) ruang laboratorium5) ruang gudang6) ruang penyimpan bahan kimia

c) Sarana pembuangan lumpur dari hasil pengurasan bak pengendap dan pencuciansaringan

92 Bahan dan bangunan pelengkap

Bahan dan bangunan pelengkap harus memenuhi ketentuan berikuta) Struktur bangunan IPA dan bangunan penampung air minum dari beton bertulang bajaatau bahan lainnya berdasarkan pertimbangan kondisi lapangan

b) Ruang genset harus kedap suara tahan getaran dan tidak mudah terbakar dilengkapidengan peralatan perneliharaan yang memenuhi ketentuan yang berlaku

c) Ruang pembubuh dan penyimpan bahan kimia dilengkapi exhaust fan drainase danperlengkapan pembersihan

d) Bangunan penunjang lainnya menggunakan bahan bangunan yang memenuhi ketentuanyang berlaku

e) Pondasi bangunan sesuai dengan kondisi setempat yang memenuhi ketentuan yangberlaku

10 Rencana tapak dan sarana pelengkap

a) Rancangan tapak harus mengikuti peraturan mendirikan bangunan yang berlakusetempat

b) Apabila tidak ditentukan oleh peraturan setempat yang ada untuk kemudahan operasidan pemeliharaan jarak bagian terluar IPA paket terhadap bangunan lain disekitarnyayang terdekat sekurang-kurangnya sebagai berikut1) 3 0 meter untuk IPA dengan Kapasitas sampai dengan 20 Ldetik2) 40 meter untuk IPA dengan kapasitas diatas 20 Ldetik

c) Luas rencana tapak dan pelengkap bangunan harus memenuh ketentuan luas berikut1) kapasitas sampai dengan 5 Ldetik luas minimal 2000 m22) kapasiras (10 ndash 30) Ldetik luas minimal 2400 m2 3) kapasitas (40 ndash 80) Ldetik luas minimal 3000 m2

d) Tata letak bangunan penunjang IPA berdasarkan mudah operasi sirkulasi dan efisien dilengkapi tempat parkir pagar kamar mandi toilet dan fasilitas penerangan

e) Untuk kebutuhan operasi dan pemeliharaan paket unit IPA harus dilengkapi denganlantai pemeriksaan

f) Jalan masuk dari jalan besar menuju ke tapak IPA lebarnya harus mencukupi untukdilalui kendaraan roda empat

g) Jalan dan tempat parkir harus diberikan perkerasan yang memadaih) Tapak IPA haruas bebas banjir

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 15: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1522

Revisi SNI 19-6774-2002

12 dari 19Kembali

11 Dokumen perencanaan

Dokumen Perencanaan untuk IPA paket sekurang-kurangnya terdiri dari a) Diagram alir prosesb) Diagram perpipaan dan Instrumentasic) Perhitungan unit proses dan operasid) Profil hidrolise) Perhitungan mekanikal dan elektrikalf) Perhitungan struktur g) Gambar perencanaan dengan skala yang memadai

12 Persyaratan untuk perencana

Perencana yang berwenang untuk merencanakan IPA paket adalah seorang yang telahmenempuh pendidikan tinggi dalam bidang yang sesuai dan memiliki sertifikat keahlian yangdikeluarkan oleh asosiasi profesi

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 16: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1622

Revisi SNI 19-6774-2002

13 dari 19Kembali

Lampiran A(Informatif)

Daftar istilah

Ukuran efektif effective size Bilangan froude Froude number Gradien kecepatan velocity gradient Bilangan reynold Reynold number Waktu d detention time Koef keseragaman uniformity coefficient Lubang pemeriksaan manhole Lantai pemeriksaan bordes Pencucian antar saringan inter filter backwashing Kehilangan tekanan headloss

Kipas impeller Saluran pembuangan underdrain Soda abu sodium carbonate Soda api sodium hidroside Kaporit calcium hipochlorit Tumpuan putaran hearing Pencucian permukaan surface washing Pencucian dari bawah ke atas back washing Klarifayer clarifier Aliran air dari bawah ke atas upflow Beban hidrolik permukaan hydraulics surface loading

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 17: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1722

Revisi SNI 19-6774-2002

14 dari 19Kembali

Lampiran B(Informatif)

Daftar notasi

ES Effective Size Nfr Froude Number G Gradient NTU Nephelometric Turbidity Unit Nre Reynold number SPC Saringan Pasir Cepat uPt Co Unit platinum Cobalt TCU Total Colour Unit td Detention Time UB Ukuran butir UC Uniformity Coefisient

DPC Daya pengikat Klor U Kinematik viskositas air g Berat jenis air

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 18: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1822

Revisi SNI 19-6774-2002

15 dari 19Kembali

Lampiran C(Informatif)

Penentuan dimensi unit paket IPA

1 Penentuan dimensi unit paket IPA

11 Unit koagulasi (pengaduk cepat)

Dimensi unit koagulasi (pengaduk cepat) dapat ditentukan dengan rumus1) Tipe hidrolis dengan jenis pengaduk statis

Q = A v (1)

Q = frac14 π D2 v (2)

gv

D L f h f 2

2

= (3)

gvk h f 22

= (4)

C h

QGf

μ ρ

2= (5)

5406308490 S RC v n= (6)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)D adalah diameter pipa (m)v adalah kecepatan aliran (mdet)

hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)g adalah gravitasi (981 mdetik)f adalah koefisien kehilangan melalui pipa (002 - 026)

k adalah koefisien kehilangan melalui perlengkapan pipa (07 -1)micro adalah viskositas kinematik air (m2detik)C adalah kapasitas bak (m3)Cn adalah koefisien kekasaran pipaS adalah kemiringan hidrolis (mm)R adalah jari-jari hidrolis (m) ρ adalah masa jenis air (gcm3)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

K

P = ρ n

3

D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 19: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 1922

Revisi SNI 19-6774-2002

16 dari 19Kembali

12 Unit flokulasi (pengaduk lambat)

Dimensi unit flokulasi (pengaduk lambat) dapat ditentukan dengan rumus sebagai berikut1) Tipe hidrolis dengan jenis pengaduk statis

d t QC = (7)

d t Q pxlxd = (8)

d f t hgG 2

μ = (9)

dengan pengertianQ adalah kapasitas pengolahan (m3detik)p adalah panjang bak(m)l adalah lebar bak (m)d adalah tinggi (m)td adalah waktu tinggal (detik)G adalah gradien G (detik-1)hf adalah kehilangan tekanan pada pipa dan perlengkapannya (m kolom air)micro adalah viskositas kinematik air (mdetik)

g adalah gravitasi (981 mdetik2)

2) Tipe hidrolis dengan jenis pengaduk mekanis

dengan pengertianP adalah tenaga yang diperlukan (gcmdet)n adalah putaran (rpm)gc adalah faktor konversi NewtonD adalah diamater impeller (cm)

K adalah konstanta experimen (10 ndash 50) ρ adalah masa jenis air (gcm3)

13 Unit sedimentasi (pengendap)

Dimensi unit sedimentasi dapat ditentukan dengan rumus sebagai berikut

( )α α 2

WCos HCosS

W Q A

o+

= (10)

dengan pengertianA adalah luas permukaan bak (m2)Q adalah Kapasitas pengolahan (cm)W adalah Jarak antar pelat (cm)So adalah Beban permukaan (cmdetik)H adalah Tinggi Delat (cm)α adalah Kemiringan pelat (deg)

K

P = ρ n 3 D

5

g c

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 20: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2022

Revisi SNI 19-6774-2002

17 dari 19Kembali

14 Unit filtrasi (penyaring)

Dimensi unit fltrasi (penyaring) dapat ditentukan dengan rumus sebagai berikut

Q = Aν v

Q A = (11)

dengan pengertianQ adalah Kapasitas pengolahan (m3detik)A adalah Luas bak (m2)v adalah Kecepatan penyaringan (mdetik)

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 21: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2122

Revisi SNI 19-6774-2002

18 dari 19Kembali

Lampiran D(Informatif)

Daftar nama dan lembaga

1) Pemrakarsa

Pusat Penelitian dan Pengembangan Permukiman Badan Penelitian danPengembangan Departemen Pekerjaan Umum

2) Penyusun

N a m a LembagaIr NurhasanahMM Puslitbang Permukiman

Atang SarbiniST Puslitbang Permukiman

MurdiyatiST Puslitbang PermukimanIrASunandi Hidayat Puslitbang Permukiman

Alia Rainy DamayantiST Puslitbang Permukiman

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft

Schulz and Okun 1984 Surface Water Treatment for Communities in Developing Countries John Wiley amp Sons

Page 22: SNI DT-91-0002-2007

582018 SNI DT-91-0002-2007 - slidepdfcom

httpslidepdfcomreaderfullsni-dt-91-0002-2007 2222

Revisi SNI 19-6774-2002

19 dari 19Kembali

Bibliografi

Birdi GS Water Supply and Sanitary Engineering Second Edition 1979

Degremount Water and the Environment Water Treatment Hand Books Sixth Editionvolume 1 1991

Fair LGeyer and Okun Element of Water Supply and Waste Water Treatment 1971

Hamer Mark J 1977 Water and Waste Water Technology SI Version John Wiley amp Sons

Inc

Huisman 1971 Rapid Sand Filter IHE Delft