SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure...

20
SMOKE VENTILATION

Transcript of SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure...

Page 1: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

SMOKE VENTILATION

Page 2: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

Introduction ........................................................04

Vents ...................................................................08

SV-W-GL ................................................................09

SV-W-L .................................................................11

SV-W-D ..................................................................13

SV-W-SD................................................................15

SV-R-RL .................................................................17

SV-R-L ...................................................................19

SV-R-CP ................................................................21

Controls .............................................................24

VCS-S2 ..................................................................25

WSC 204 ..............................................................27

WSC 520/540/560 .............................................29

Accessories ........................................................34

BG1/S ...................................................................35

BG1/FOS ..............................................................35

BG2/FOS ..............................................................35

SSR-D ...................................................................35

WLA 330 ..............................................................35

WLA 331 ...............................................................35

WSK 320 ..............................................................35

WSK 501 ..............................................................35

Spare Parts

Replacement keys, batteries, glass, PCB’s, enclosures, and many more ..........................36

Actuators

Chain actuators, linear actuators, folding arm actuators ......................................36

V E N T S

Smoke Vents are designed to release smoke within a certain area of the building ie; Stairwells, Corridors or Lobbies. Our range of smoke vents include rooflights, windows, louvres, doors and dampers. All are available in a range of sizes to suit almost any application. Each of them has been tested to the relevant European EN Standards.

Voltage 24V DCFree Area 1m² or 1.5m²

C O N T R O L S

Smoke Ventilation Systems are an integral part of Fire and Safety strategies within building environments. Single or multi-zone control units are used to power AOV(s) throughout the building. Each can be triggered using smoke sensors, fire alarms, callpoints, switches or climate sensors.

Voltage Output 24V DCMotor Load 4.8A, 10A, 20A, 40A or 60AMotor Lines 1-39Inputs for Manual Callpoints, Smoke Sensor, Fire Alarm, Switch, Thermostat, Wind Sensor, Rain Sensor, CO2 or BMS

VENTS

CONTROLS

VENTS

CONTROLS

INTRODUCTIONCONTENTS

43

Page 3: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

S T A I R W E L LS M O K E S H A F T

S M O K E S E N S O R

Used to trigger the AOV control unit in the event of smoke detection.

M A N U A L C A L L P O I N T

Used for the manual activation of the smoke system via AOV control unit.

C O N T R O L U N I T

An AOV control unit can be used to operate single or multiple AOV’s throughout the building.

A O V

The smoke vent at the head of a stairwellmust achieve a minimum free area of 1m². This can be in the form of a rooflight, window or louvre vent.

M A N U A L C A L L P O I N T

Used for the manual activation of the smoke system via AOV control unit.

S M O K E S E N S O R

Used to trigger the AOV control unit in the event of smoke detection.

C O N T R O L U N I T

An AOV control unit can be used to operate single or multiple AOV’s throughout the building.

A O V

A corridor or lobby smoke vent opening into a shaft must achieve a minimum free area of 1m². This can be in the form of a door or damper vent.

A O V

The smoke vent at the head of shaft must achieve a minimum free area of 1.5m². This can be in the form of a rooflight or louvre vent.

APPLICATION

5 6

Page 4: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

VENTSP R O D U C T C O M P A R I S O N

V E N T S

Code egaP

AOV Glazed Wall Louvre

AOV Wall Louvre

AOV Wall Damper

1

1

1

SV-W-GL

SV-W-L

SV-W-D

Description

24V DC

24V DC

24V DC

Voltage

1 m² or 1.5 m²

1 m² or 1.5 m²

0.51 m²

Free Area

Bespoke

1090x1090mm, 1290x1310mm or bespoke

775x1025mm

AOV Rooflight

AOV Roof Louvre

AOV Centre Pivot Window

1

1

1

SV-R-RL

SV-R-L

SV-R-CP

24V DC

24V DC

24V DC

1 m² or 1.5 m²

1 m² or 1.5 m²

1 m² or 1.5 m²

1050x1050mm, 1200x1200mm, 1500x1500mm, 2000x1100mm or bespoke

AOV Smoke Door 1SV-W-SD 24V DC 1 m² 1000x1500mm

1090x1090mm, 1290x1310mm or bespoke

1140x1180mm or 1340x1400m

Sizes

P R O D U C T C O M P A R I S O N

7

9

11

13

15

17

19

21

8

Page 5: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-W-GLLOUVREVENTS

Vent

s / W

all /

Lou

vre

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E SBespoke

F R E E A R E A

1 m² or 1.5 m²

SV-W-GLGLAZED LOUVRE

D E S C R I P T I O N

The SV-W-GL Louvre Window is preferred by many of our clients due to its outstanding advanatages in regard to ventilation, weather tightness and thermal protection, as well as s a high degree of security (burglar proof RC2). The glass louvres are framed with aluminium proles.

The SV-W-GL is certied for use as NSHV (Natural Smoke

and Heat Ventilation) device according to EN 12101-2,

furthermore it is available ball protection proof suitable for

use in sports facilities (DIN 18032-3)

F R E E A R E A1 m² or 1.5 m²

V R E

T E C H N I C A L D A T A

Frame AL-proles, thermal broken

Blades Insulated glass, aluminium prole

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.7 A

Colour Custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-W-GLL OUV R EVENTS

Vent

s / W

all /

Lou

vre

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

Vent

s / W

all /

Lou

vre

T E C H N I C A L D A T A

Frame AL-proles, thermal broken

Blades Insulated glass, aluminium prole

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.7 A

Colour Custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-W-GLL OUV R EVENTS

Vent

s / W

all /

Lou

vre

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

9 10

Page 6: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-W-LLOUVREVENTS

Vent

s / W

all /

Lou

vre

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S1090 x 1090 mm or 1290 x 1310 mm

F R E E A R E A

1 m² or 1.5 m²

SV-W-LLOUVRE

D E S C R I P T I O N

The wall SV-W-L is an attractive, economical low prole louvred ventilator which has been specically designed for both smoke and heat exhaust and natural ventilation applications (SHEV). The system offers effective re safety with units tested for use as smoke ventilators to BS EN 12101-2.

High efficiency - aerodynamically tested to BS EN 12101-2:2003Weatherproof - its resistance to air leakage and rainwater is tested to BS 5368 and BS 6375

The wall SV-W-L can be supplied with both insulated louvre blades and an insulated body to assist in ensuring the building is adequately insulated. Also the SV-W-L can be manufactured with polycarbonate blades. Translucent polycarbonate louvre blades provide excellent daylighting using a durable UV stabilised material. When closed it can provide an average diffused light transmission in excess of 80%, enabling savings on articial lighting. Pile weather seals are also tted to the louvre blade edges and sides to minimise heat loss.

T E C H N I C A L D A T A

Frame 1.5 mm press formed aluminium

Blades 1.5 mm single skin aluminium.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.6 A

Colour Mill Finish or custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-W-L-1090X1090 - AOV Wall Louvre 1090 x 1090 mm 1 m²

SV-W-L-1290X1310 - AOV Wall Louvre 1290 x 1310 mm 1.5 m²

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-LL OUV R EVENTS

Vent

s / W

all /

Lou

vre

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

Vent

s / W

all /

Lou

vreT E C H N I C A L D A T A

Frame 1.5 mm press formed aluminium

Blades 1.5 mm single skin aluminium.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.6 A

Colour Mill Finish or custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-W-L-1090X1090 - AOV Wall Louvre 1090 x 1090 mm 1 m²

SV-W-L-1290X1310 - AOV Wall Louvre 1290 x 1310 mm 1.5 m²

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-LL OUV R EVENTS

Vent

s / W

all /

Lou

vre

T E C H N I C A L D A T A

Frame 1.5 mm press formed aluminium

Blades 1.5 mm single skin aluminium.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.6 A

Colour Mill Finish or custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-W-L-1090X1090 - AOV Wall Louvre 1090 x 1090 mm 1 m²

SV-W-L-1290X1310 - AOV Wall Louvre 1290 x 1310 mm 1.5 m²

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-LL OUV R EVENTS

Vent

s / W

all /

Lou

vre

11 12

Page 7: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-W-DDAMPERVENTS

Vent

s / W

all /

Dam

per

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S775 x 1025 mm

F R E E A R E A

0.51 m²

SV-W-DDAMPER

D E S C R I P T I O N

The SV-W-D smoke damper range has been designed to satisfy smoke ventilation applications and is particularly suited for smoke evacuation shafts and risers in multi storey buildings.

A multi, parallel linked blade smoke damper the SV-W-D is manufactured from robust 1.5 mm galvanised steel. Usefully the damper combines both a low leakage rate, when closed, with a high free area, when open, to support high smoke evacuation rates.

Certified and tested in accordance to EN 12101-8

Supplied complete with fascia cover grille

T E C H N I C A L D A T A

noitcurtsnoc leets desinavlaG mm 5.1emarF

leets desinavlag ediw mm003 ot mm001 x kciht mm0.1 morf detcurtsnoc ylbmessa edalb lellaraPsedalB

0.5m²aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 23.0noitpmusnoC tnerruC

)ellirG( etihW dna )repmaD( hsiniF lliMruoloC

1 x Vent, 1 x Grille & 1 x Actuator

Certifi 8-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

- AOV Wall Damper 775 x 1025 mm 0.51 m²

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-DDAM PERVENTS

Vent

s / W

all /

Dam

per

SV-W-D-775X1025

Vent

s / W

all /

Dam

per

T E C H N I C A L D A T A

noitcurtsnoc leets desinavlaG mm 5.1emarF

leets desinavlag ediw mm003 ot mm001 x kciht mm0.1 morf detcurtsnoc ylbmessa edalb lellaraPsedalB

0.5m²aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 23.0noitpmusnoC tnerruC

)ellirG( etihW dna )repmaD( hsiniF lliMruoloC

1 x Vent, 1 x Grille & 1 x Actuator

Certifi 8-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

- AOV Wall Damper 775 x 1025 mm 0.51 m²

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-DDAM PERVENTS

Vent

s / W

all /

Dam

per

SV-W-D-775X1025

13 14

Page 8: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-W-DSHAFT DOORVENTS

Vent

s / W

all /

Sha

ft D

oor

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S1000 x 1500 mm

F R E E A R E A

1 m²

SV-W-SD

D E S C R I P T I O N

Certified and tested in accordance to EN 12101-2

SHAFT DOOR

SV-W-SD AOV Shaft Door is CE marked and fully certified to BS EN12101-2 and to Building Regulations ADB and ADL.They may be installed vertically or horizontally into a variety of walls or ceilings and their design provides a flush, unobtrusive finish.Manufactured from steel, fully welded with full length concealed piano hinge and are supplied paint-ready or powder-coated.Tested to 11,000 opening cycles, which may they can also be used for comfort cooling. Airtight to Part L EN12207:2000 and BS EN2176 Part 31, they are powered by 24V DC actuators with a drive open, drive close operation.Unit includes 3 point locking access panel which opens towards the user and is supplied with a square drive key through the round keyhole in the door face after removal of the white plastic cap.

Vent

s / W

all /

Sha

ft D

oor

T E C H N I C A L D A T A

Fully welded four-sided rigid steel frame constructionemarF

²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

4 A1.noitpmusnoC tnerruC

e (standard) or any specific RAL colourtihW ruoloC

1 x Vent, & 1 x Actuator

Certifi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

- AOV

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-SDVENTS

Vent

s / W

all /

Sha

ft D

oor

SV-W-SD

SHAFT DOOR

Shaft Door 1000 x 1500 mm 1 m²

T E C H N I C A L D A T A

Fully welded four-sided rigid steel frame constructionemarF

²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

4 A1.noitpmusnoC tnerruC

e (standard) or any specific RAL colourtihW ruoloC

1 x Vent, & 1 x Actuator

Certifi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

- AOV

P A R T C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

S60 Rocker Switch

WSC 204

SV-W-SDVENTS

Vent

s / W

all /

Sha

ft D

oor

SV-W-SD

SHAFT DOOR

Shaft Door 1000 x 1500 mm 1 m²

15 16

Page 9: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-R-RLROOFL IGHTVENTS

Vent

s / R

oof /

Roo

igh

t

R O O F T Y P E S

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S1050 x 1050 mm, 1200 x 1200 mm, 1500 x 1500 mm or 2000 x 1100 mm

F R E E A R E A

1 m² or 1.5 m² (depending on vent size)

SV-R-RLROOFL IGHT

D E S C R I P T I O N

Manufactured in the UK from high grade aluminium alloy, Smoke Release Hatches incorporate high quality European-made gear motor opening mechanisms, to combine excellent durability and reliable operation.

Tested/manufactured to EN 12101-2:2003 annex ZA, which covers all performance categories under this standard.

Suitable for all types of at /pitched roofs

Lid options include: insulated aluminium; double glazed glass; clear or opal UV protected polycarbonate dome

24 Volt high temperature actuators

Mechanism facilitates opening to 140º

Can be supplied with: control panel with

Standard mill nish aluminium to external surfaces, with white polyester powder coat

RAL colours can also be specied

T E C H N I C A L D A T A

Frame Aluminium, aluminium to BS 1474:1987 Alloy 6063-T6.

Kerb Aluminium upstand – 350 mm high for Smoke Release Hatches with gear motor actuators.

Lid Clear or opal non fragile UV protected polycarbonate dome lid to open 140°.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

U Value 50mm Insulation with a ‘U’ Value 0.25 W/m²K. Overall ‘U’ Value 0.70 W/m²K.

Voltage 24V DC

Opening 140°

Opening Speed > 60 secs

Current Consumption 7.5 A

Colour Mill Finish (external) and White (internal)

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 2-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-RLR OOFL IGHTVENTS

Vent

s / R

oof /

Roo

igh

t

SV-R-RL-1050X1050 - AOV Rooight Polycarbonate Dome 1050 x 1050 mm 1 m²

SV-R-RL-1200X1200 - AOV Rooight Polycarbonate Dome 1200 x 1200 mm 1 m²

SV-R-RL-1500X1500 - AOV Rooight Polycarbonate Dome 1500 x 1500 mm 1.5 m²

SV-R-RL-2000X1100 - AOV Rooight Polycarbonate Dome 2000 x 1100 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 310AOV Control Unit

WSK 501 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

WSC 310 SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

Vent

s / R

oof /

Roo

fligh

t

T E C H N I C A L D A T A

Frame Aluminium, aluminium to BS 1474:1987 Alloy 6063-T6.

Kerb Aluminium upstand – 350 mm high for Smoke Release Hatches with gear motor actuators.

Lid Clear or opal non fragile UV protected polycarbonate dome lid to open 140°.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

U Value 50mm Insulation with a ‘U’ Value 0.25 W/m²K. Overall ‘U’ Value 0.70 W/m²K.

Voltage 24V DC

Opening 140°

Opening Speed > 60 secs

Current Consumption 7.5 A

Colour Mill Finish (external) and White (internal)

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 2-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-RLROOFL IGH TVENTS

Vent

s / R

oof /

Roo

igh

t

SV-R-RL-1050X1050 - AOV Rooight Polycarbonate Dome 1050 x 1050 mm 1 m²

SV-R-RL-1200X1200 - AOV Rooight Polycarbonate Dome 1200 x 1200 mm 1 m²

SV-R-RL-1500X1500 - AOV Rooight Polycarbonate Dome 1500 x 1500 mm 1.5 m²

SV-R-RL-2000X1100 - AOV Rooight Polycarbonate Dome 2000 x 1100 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 310AOV Control Unit

WSK 501 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

WSC 310 SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

T E C H N I C A L D A T A

Frame Aluminium, aluminium to BS 1474:1987 Alloy 6063-T6.

Kerb Aluminium upstand – 350 mm high for Smoke Release Hatches with gear motor actuators.

Lid Clear or opal non fragile UV protected polycarbonate dome lid to open 140°.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

U Value 50mm Insulation with a ‘U’ Value 0.25 W/m²K. Overall ‘U’ Value 0.70 W/m²K.

Voltage 24V DC

Opening 140°

Opening Speed > 60 secs

Current Consumption 7.5 A

Colour Mill Finish (external) and White (internal)

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 2-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-RLROOFL IGH TVENTS

Vent

s / R

oof /

Roo

igh

t

SV-R-RL-1050X1050 - AOV Rooight Polycarbonate Dome 1050 x 1050 mm 1 m²

SV-R-RL-1200X1200 - AOV Rooight Polycarbonate Dome 1200 x 1200 mm 1 m²

SV-R-RL-1500X1500 - AOV Rooight Polycarbonate Dome 1500 x 1500 mm 1.5 m²

SV-R-RL-2000X1100 - AOV Rooight Polycarbonate Dome 2000 x 1100 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 310AOV Control Unit

WSK 501 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

WSC 310 SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

17 18

Page 10: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-R-LLOUVREVENTS

Vent

s / R

oof /

Lou

vre

R O O F T Y P E S

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S1090 x 1090 mm or 1290 x 1310 mm

F R E E A R E A

1 m² or 1.5 m² (depending on vent size)

SV-R-LLOUVRE

D E S C R I P T I O N

SV-R-L is a highly-efficient, attractive, low prole louvred smoke and natural ventilator which has been specically designed for both smoke and heat exhaust and natural ventilation applications. SV-R-L can be roof mounted for exhaust or air inlet. The system offers effective re safety with units tested for use as smoke ventilators to BS EN 12101-2.

High efficiency - aerodynamically tested to BS EN 12101-2:2003.

Weatherproof - its resistance to air leakage and rainwater is tested to BS 5368 and BS 6375.

Durability - tested to withstand wind loads of class WL1500 and snow loads of up to class SL500 under BS EN 12101-2:2003.

The ventilator is supplied in two parts to facilitate easy installation on site, the base assembly and louvre box assembly. Turndown Base - mounting onto weathered roof upstand.

Vent

s / R

oof /

Lou

vre

T E C H N I C A L D A T A

Frame 1.5 mm press formed aluminium

Blades 1.5 mm single skin aluminium.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size).

U Value 6W/m²°k

Voltage 24V DC

Opening Speed > 60 secs

Current Consumption 0.6 A

Colour Mill Finish or custom RAL colour

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-L-1090X1090 - AOV Roof Louvre 1090 x 1090 mm 1 m²

SV-R-L-1290X1310 - AOV Roof Louvre 1290 x 1310 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

SV-R-LL OUV R EVENTS

Vent

s / R

oof /

Lou

vre

WSC 204

T E C H N I C A L D A T A

Frame Aluminium, aluminium to BS 1474:1987 Alloy 6063-T6.

Kerb Aluminium upstand – 350 mm high for Smoke Release Hatches with gear motor actuators.

Lid Clear or opal non fragile UV protected polycarbonate dome lid to open 140°.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

U Value 50mm Insulation with a ‘U’ Value 0.25 W/m²K. Overall ‘U’ Value 0.70 W/m²K.

Voltage 24V DC

Opening 140°

Opening Speed > 60 secs

Current Consumption 7.5 A

Colour Mill Finish (external) and White (internal)

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 2-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-RLROOFL IGH TVENTS

Vent

s / R

oof /

Roo

igh

t

SV-R-RL-1050X1050 - AOV Rooight Polycarbonate Dome 1050 x 1050 mm 1 m²

SV-R-RL-1200X1200 - AOV Rooight Polycarbonate Dome 1200 x 1200 mm 1 m²

SV-R-RL-1500X1500 - AOV Rooight Polycarbonate Dome 1500 x 1500 mm 1.5 m²

SV-R-RL-2000X1100 - AOV Rooight Polycarbonate Dome 2000 x 1100 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 310AOV Control Unit

WSK 501 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

WSC 310 SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

T E C H N I C A L D A T A

Frame Aluminium, aluminium to BS 1474:1987 Alloy 6063-T6.

Kerb Aluminium upstand – 350 mm high for Smoke Release Hatches with gear motor actuators.

Lid Clear or opal non fragile UV protected polycarbonate dome lid to open 140°.

Geometric Free Area 1 m² or 1.5 m² (depending on vent size)

U Value 50mm Insulation with a ‘U’ Value 0.25 W/m²K. Overall ‘U’ Value 0.70 W/m²K.

Voltage 24V DC

Opening 140°

Opening Speed > 60 secs

Current Consumption 7.5 A

Colour Mill Finish (external) and White (internal)

1 x Vent & 1 x Actuator

Certication EN 12101-2

Delivery Includes

Cable Dimensions 2-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-RLROOFL IGH TVENTS

Vent

s / R

oof /

Roo

igh

t

SV-R-RL-1050X1050 - AOV Rooight Polycarbonate Dome 1050 x 1050 mm 1 m²

SV-R-RL-1200X1200 - AOV Rooight Polycarbonate Dome 1200 x 1200 mm 1 m²

SV-R-RL-1500X1500 - AOV Rooight Polycarbonate Dome 1500 x 1500 mm 1.5 m²

SV-R-RL-2000X1100 - AOV Rooight Polycarbonate Dome 2000 x 1100 mm 1.5 m²

P A R T S C O D E S

C O N T R O L S

WSC 310AOV Control Unit

WSK 501 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

WSC 310 SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

19 20

Page 11: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

SV-R-CPCENTRE-P IVOT WINDOWVENTS

R O O F T Y P E S

C E R T I F I C A T I O N

A P P L I C A T I O N

COMFORTVENTILATION

SMOKEVENTILATION

S I Z E S1140 x 1180 mm or 1340 x 1400 mm

F R E E A R E A

1 m² or 1.5 m² (depending on vent size)

SV-R-CPCENTRE-P IVOT WINDOW

D E S C R I P T I O N

Vent

s / R

oof /

Cen

tre-

Pivo

t

15-90This window is a gravitational smoke ventilation system and is used to help expel the excess of smoke and heat during a re. Additionally, the system enables daily ventilation and allows light into the room.

The SV-R-CP is equipped with an electric motor, which opens the window sash when one of the following occurs:

When smoke is detected in the atmosphereWhen the manual callpoint is triggeredOnce either of these actions occur, an electric signal from the control unit opens the sash.

This smoke ventilation window has been manufactured and certied according to harmonised standard EN 12101-2:2003.

The SV-R-CP can be installed above stairwells and corridors.

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² White

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² Pine

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² White

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² Pine

T E C H N I C A L D A T A

Pinewood (vacuum impregnated)emarF

Glass ConstructionOuter pane = 4mm toughened glass, 14mm steel spacer lled with inert argon gas. 6.8mm internal pane is an anti-burglary class of laminate 33.2

.)ezis tnev no gnidneped( ²m 5.1 ro ²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 4.1noitpmusnoC tnerruC

ruoloc LAR motsuc ro hsiniF lliMruoloC

1 x Vent & 1 x Actuator

Certi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-CP-1140X1180 -

SV-R-CP-1140X1180-W -

SV-R-CP-1340X1400 -

SV-R-CP-1340X1400-W -

P A R T S C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

SV-R-CPCENTRE-P IVOT WINDOWVENTS

WSC 204

Vent

s / R

oof /

Cen

tre-

Pivo

tVe

nts

/ Wal

l / L

ouvr

e

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² White

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² Pine

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² White

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² Pine

T E C H N I C A L D A T A

Pinewood (vacuum impregnated)emarF

Glass ConstructionOuter pane = 4mm toughened glass, 14mm steel spacer lled with inert argon gas. 6.8mm internal pane is an anti-burglary class of laminate 33.2

.)ezis tnev no gnidneped( ²m 5.1 ro ²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 4.1noitpmusnoC tnerruC

ruoloc LAR motsuc ro hsiniF lliMruoloC

1 x Vent & 1 x Actuator

Certi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-CP-1140X1180 -

SV-R-CP-1140X1180-W -

SV-R-CP-1340X1400 -

SV-R-CP-1340X1400-W -

P A R T S C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

SV-R-CPCENTRE-P IVOT WINDOWVENTS

WSC 204

Vent

s / R

oof /

Cen

tre-

Pivo

t

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² White

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² Pine

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² White

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² Pine

T E C H N I C A L D A T A

Pinewood (vacuum impregnated)emarF

Glass ConstructionOuter pane = 4mm toughened glass, 14mm steel spacer lled with inert argon gas. 6.8mm internal pane is an anti-burglary class of laminate 33.2

.)ezis tnev no gnidneped( ²m 5.1 ro ²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 4.1noitpmusnoC tnerruC

ruoloc LAR motsuc ro hsiniF lliMruoloC

1 x Vent & 1 x Actuator

Certi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-CP-1140X1180 -

SV-R-CP-1140X1180-W -

SV-R-CP-1340X1400 -

SV-R-CP-1340X1400-W -

P A R T S C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

SV-R-CPCENTRE-P IVOT WINDOWVENTS

WSC 204

Vent

s / R

oof /

Cen

tre-

Pivo

t

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² White

AOV Roof Centre Pivot 1340 x 1400 mm 1.5 m² Pine

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² White

AOV Roof Centre Pivot 1140 x 1180 mm 1 m² Pine

T E C H N I C A L D A T A

Pinewood (vacuum impregnated)emarF

Glass ConstructionOuter pane = 4mm toughened glass, 14mm steel spacer lled with inert argon gas. 6.8mm internal pane is an anti-burglary class of laminate 33.2

.)ezis tnev no gnidneped( ²m 5.1 ro ²m 1aerA eerF cirtemoeG

CD V42egatloV

sces 06 >deepS gninepO

A 4.1noitpmusnoC tnerruC

ruoloc LAR motsuc ro hsiniF lliMruoloC

1 x Vent & 1 x Actuator

Certi 2-10121 NEnoitac

Delivery Includes

Cable Dimensions 3-Core

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

SV-R-CP-1140X1180 -

SV-R-CP-1140X1180-W -

SV-R-CP-1340X1400 -

SV-R-CP-1340X1400-W -

P A R T S C O D E S

C O N T R O L S

WSC 204AOV Control Unit

WSK 320 Override Switch

SSR-DSmoke Sensor

WLA 330 Wind & Rain Sensor

SSR-DSmoke Sensor Wind

WLA 330& Rain Sensor

WWind

SV-R-CPCENTRE-P IVOT WINDOWVENTS

WSC 204

Vent

s / R

oof /

Cen

tre-

Pivo

t

21 22

Page 12: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

CONTROLS

P R O D U C T C O M P A R I S O N

C O N T R O L U N I T S

CodeegaP

230V AC

230V AC

230V AC

1

1

1

VCS-S2

WSC 204

WSC 520/540/560

= With additional module (WSA 306)

Manual Callpoint

Smoke Sensor

Wind/Rain Sensor

BMS

Interlinked

Fire Alarm

Inputs for

Voltage(Input)

24V DC

24V DC

24V DC

Voltage(Input)

5 A

4.8 A

20 / 40 / 60 A

Motor Load

1

1

1 - 39

Motor Lines

P R O D U C T C O M P A R I S O N

23

25

27

29

24

Page 13: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

VCS-S2AOV CONTROL UNIT

VCS-S2AOV CONTROL UNIT

D E S C R I P T I O N 1-Zone Smoke Control Panel. Built in override keyswitch for manual control. Can be linked to a Fire Alarm or Smoke Sensor for automatic opening of a AOV Smoke Vent(s). Manually triggered using Manual Override Switches. Complete with lead acid batteries for 72 hour battery backup on mains failure. Facility to link several Control Panels together to form a Multi-Zone system.

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

I N P U T S F O RManual Override Switch

Smoke Sensor

Fire Alarm

SwitchSMOKE

VENTILATION

A P P L I C A T I O N

V O L T A G EInput = 230V AC, Output = 24V DC

M O T O R L I N E S M O T O R L O A D1 5.0 A

C E R T I F I C A T I O NCertified and tested in accordance to EN 12101-10

BG1/FOS/O - Manual Override Switch

BG1/S/O - Breakglass Callpoint

BG2/FOS/O - Manual Override Key Switch

S50-1 - Rocker Switch

SSR-D - Optical Smoke Sensor

T E C H N I C A L D A T A

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

C O M P A T I B L E W I T H

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

Primary Voltage (Input) 230V AC

Secondary Voltage (Output) 24V DC

Motor Load 5.0 A

Motor Lines 1

Inputs Breakglass, Manual Override Switch, Manual Override Key Switch, Smoke Sensor, Fire Alarm, Switch

Operating Condition -5°C - +40°C

Battery Backup >72 hr

Size 230 x 310 x 120 mm

Protection Type IP 44

Delivery 1 x Control Unit & 2 x Batteries

Battery Size 2 x 12V 5Ah

Certification EN 12101-10

WMD 820Folding Arm Actuator

MICRO XLChain Actuator

(Multiple 24V DC actuators, total load must not exceed 5.0 A max.)

WMU 836Chain Actuator

WMU 842Chain Actuator

A C C E S S O R I E S P A R T C O D E S

VCS-S2 - VCS-S2 Control Unit 24 V 5 A

VCS-S2AOV C ONT R OL UNIT

VCS-S2Control Unit

VCS-S2Control Unit

BG1/FOSFiremans Override Switch

230V AC Mains Power

BG1/SBreak glass Callpoint

VCS-S2

SSR-D

FIRE ALARM

Smoke Sensor

BG2/FOSFiremans Override Key Switch

NO / C

AOVc/w 24V DC Actuator

Elec

tric

/ Sm

oke

Vent

ilati

on /

Cont

rol U

nits

25 26

Page 14: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

WSC 204/KPAOV CONTROL UNIT

WSC 204/KPAOV CONTROL UNIT

D E S C R I P T I O N 1 smoke / comfort ventilation group control of window actuators up to 4.8A with microprocessor smoke extraction and comfort ventilation in smaller and medium sized buildings expandable with additional modules incl. 2 pcs. back-up batteries type WSA 003. Smoke control panel for control of 24V DC actuators for smoke extraction and daily comfort ventilation. The smoke control panel is especially suitable for surveillance of smaller areas, e.g. staircases, smaller sport centres and restaurants.

W S C 2 0 4 K P W S C 2 0 4

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

I N P U T S F O RManual Overrise Switch

Fire Alarm (with WSA 306 module)

Switch

Thermostat

Wind Sensor

Rain Sensor

SMOKEVENTILATION

A P P L I C A T I O N

V O L T A G EInput = 230V AC, Output = 24V DC

M O T O R L I N E S M O T O R L O A D1 4.8 A

C E R T I F I C A T I O NCertified and tested in accordance to EN 12101-10

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

D E S C R I P T I O N ( C O N T I N U E D )

WSC 204 / WSC 204BZ / WSC 204KP. The smoke control panel is supplied in plastic housing and can be either countersunk mounted or surface mounted (frame for surface mounting is supplied). WSC 204. The smoke control panel opens the windows actuators during smoke. WSC 204BZ The smoke control panel closes the windows actuators during smoke. WSC 204KP The smoke control panel opens the windows actuators during smoke. The panel is supplied with one break glass unit and one keypad both integrated in the door. As the keypad and break glass unit are internal to the smoke panel installation is easy and quick and saves costs. The keypad is used for daily comfort ventilation. WSC 204MH The smoke control panel opens the windows actuators during smoke. The smoke control panel is supplied in steel housing and is suitable for surface mounting.

Extension By linking several smoke control panels in a master/slave system, the smoke control unit can also be used in larger buildings (master/slave module type WSA 301 required). Special technical features approval according to EN 12101-10 for smoke extraction combined with comfort ventilation built-in uninterruptible power supply 2 pcs. WSA 003 (min. 72h battery back-up in case of voltage loss) cable surveillance on break glass unit cable surveillance on smoke detector input (if used) survey on actuator outlet breakage of smoke signal lines 1 and 2 are seen separately via diodes on the bottom plate fault display via diagnostic LEDs incident reporting is programmable as smoke triggering smoke triggering when temperature inside the compact unit exceeds 72°C. Connection options acuator with end switch or electronical load switch of tripping by BMS via potential-free contact (ASV module WSA 306 required) in connection with comfort ventilation signals from BMSunits can be received wind/rain sensor without additional plug in module 15 ventilation keypads with ”indicator” or as many ”open” indicators 10 smoke detectors type WSA 300 61 or WSA 310 4 break glass units (primary), type WSK 320 or type WSK 321 15 break glass units (secondary), type WSK 330

WSC 204/KPAOV C ONT R OL UNIT

T E C H N I C A L D A T A

Primary Voltage (Input) 230V AC

Secondary Voltage (Output) 24V DC

Motor Load 4.8 A

Motor Lines 1

Inputs Manual Override Switch, Smoke Sensor, Fire Alarm, Switch, Thermostat, Wind Sensor, Rain Sensor

Operating Condition -5°C - +40°C

Battery Backup >72 hr

Size 368 x 353 x 97 mm

Protection Type IP 30

Delivery 1 x Control Unit & 2 x Batteries

Battery Size 2 x 12V 3.4Ah

Certification EN 12101-10

WSC 204Control Unit

WSK 320Manual Callpoint

WLA 331Rain Sensor

230V AC Mains Power

SSR-DSmoke Sensor

WSC 204

FIRE ALARM

WLA 330Wind & Rain Sensor

With additional module (WSA 306)

AOVc/w 24V DC Actuator

Elec

tric

/ Sm

oke

Vent

ilati

on /

Cont

rol U

nits

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

D E S C R I P T I O N ( C O N T I N U E D )

WSC 204 / WSC 204BZ / WSC 204KP. The smoke control panel is supplied in plastic housing and can be either countersunk mounted or surface mounted (frame for surface mounting is supplied). WSC 204. The smoke control panel opens the windows actuators during smoke. WSC 204BZ The smoke control panel closes the windows actuators during smoke. WSC 204KP The smoke control panel opens the windows actuators during smoke. The panel is supplied with one break glass unit and one keypad both integrated in the door. As the keypad and break glass unit are internal to the smoke panel installation is easy and quick and saves costs. The keypad is used for daily comfort ventilation. WSC 204MH The smoke control panel opens the windows actuators during smoke. The smoke control panel is supplied in steel housing and is suitable for surface mounting.

Extension By linking several smoke control panels in a master/slave system, the smoke control unit can also be used in larger buildings (master/slave module type WSA 301 required). Special technical features approval according to EN 12101-10 for smoke extraction combined with comfort ventilation built-in uninterruptible power supply 2 pcs. WSA 003 (min. 72h battery back-up in case of voltage loss) cable surveillance on break glass unit cable surveillance on smoke detector input (if used) survey on actuator outlet breakage of smoke signal lines 1 and 2 are seen separately via diodes on the bottom plate fault display via diagnostic LEDs incident reporting is programmable as smoke triggering smoke triggering when temperature inside the compact unit exceeds 72°C. Connection options acuator with end switch or electronical load switch of tripping by BMS via potential-free contact (ASV module WSA 306 required) in connection with comfort ventilation signals from BMSunits can be received wind/rain sensor without additional plug in module 15 ventilation keypads with ”indicator” or as many ”open” indicators 10 smoke detectors type WSA 300 61 or WSA 310 4 break glass units (primary), type WSK 320 or type WSK 321 15 break glass units (secondary), type WSK 330

WSC 204/KPAOV C ONT R OL UNIT

T E C H N I C A L D A T A

Primary Voltage (Input) 230V AC

Secondary Voltage (Output) 24V DC

Motor Load 4.8 A

Motor Lines 1

Inputs Manual Override Switch, Smoke Sensor, Fire Alarm, Switch, Thermostat, Wind Sensor, Rain Sensor

Operating Condition -5°C - +40°C

Battery Backup >72 hr

Size 368 x 353 x 97 mm

Protection Type IP 30

Delivery 1 x Control Unit & 2 x Batteries

Battery Size 2 x 12V 3.4Ah

Certification EN 12101-10

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

D E S C R I P T I O N ( C O N T I N U E D )

WSC 204 / WSC 204BZ / WSC 204KP. The smoke control panel is supplied in plastic housing and can be either countersunk mounted or surface mounted (frame for surface mounting is supplied). WSC 204. The smoke control panel opens the windows actuators during smoke. WSC 204BZ The smoke control panel closes the windows actuators during smoke. WSC 204KP The smoke control panel opens the windows actuators during smoke. The panel is supplied with one break glass unit and one keypad both integrated in the door. As the keypad and break glass unit are internal to the smoke panel installation is easy and quick and saves costs. The keypad is used for daily comfort ventilation. WSC 204MH The smoke control panel opens the windows actuators during smoke. The smoke control panel is supplied in steel housing and is suitable for surface mounting.

Extension By linking several smoke control panels in a master/slave system, the smoke control unit can also be used in larger buildings (master/slave module type WSA 301 required). Special technical features approval according to EN 12101-10 for smoke extraction combined with comfort ventilation built-in uninterruptible power supply 2 pcs. WSA 003 (min. 72h battery back-up in case of voltage loss) cable surveillance on break glass unit cable surveillance on smoke detector input (if used) survey on actuator outlet breakage of smoke signal lines 1 and 2 are seen separately via diodes on the bottom plate fault display via diagnostic LEDs incident reporting is programmable as smoke triggering smoke triggering when temperature inside the compact unit exceeds 72°C. Connection options acuator with end switch or electronical load switch of tripping by BMS via potential-free contact (ASV module WSA 306 required) in connection with comfort ventilation signals from BMSunits can be received wind/rain sensor without additional plug in module 15 ventilation keypads with ”indicator” or as many ”open” indicators 10 smoke detectors type WSA 300 61 or WSA 310 4 break glass units (primary), type WSK 320 or type WSK 321 15 break glass units (secondary), type WSK 330

WSC 204/KPAOV C ONT R OL UNIT

T E C H N I C A L D A T A

Primary Voltage (Input) 230V AC

Secondary Voltage (Output) 24V DC

Motor Load 4.8 A

Motor Lines 1

Inputs Manual Override Switch, Smoke Sensor, Fire Alarm, Switch, Thermostat, Wind Sensor, Rain Sensor

Operating Condition -5°C - +40°C

Battery Backup >72 hr

Size 368 x 353 x 97 mm

Protection Type IP 30

Delivery 1 x Control Unit & 2 x Batteries

Battery Size 2 x 12V 3.4Ah

Certification EN 12101-10

SSR-D - Optical Smoke Sensor

WLA110 - Room Thermostat

WLA330 - Wind & Rain Sensor

WLA331 - Rain Sensor

WSA301 - Alarm & Fault Module

WSA306 - Fire Alarm Module

WSK100 - Ventilation Keypad

WSK320 - Manual Override Switch

WSK330 - Manual Override Switch

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

C O M P A T I B L E W I T H

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

(Multiple 24V DC actuators, total load must not exceed 4.8 A max.)

A C C E S S O R I E S P A R T C O D E S

WSC204 - WSC 204 Control Unit 24 V 4.8 A

WSC204BZ - WSC 204 Control Unit 24 V 4.8 A Close on Fire

WSC204KP - WSC 204 Control Unit 24 V 4.8 A c/w MCP

WSC204MH - WSC 204 Control Unit 24 V 4.8 A (metal housing)

WSC 204/KPAOV C ONT R OL UNIT

WMD 820Folding Arm Actuator

WMU 836Chain Actuator

WMX 826Chain Actuator

WMU 842Chain Actuator

27 28

Page 15: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

WSC 520/540/ 560AOV CO NTROL UNIT

WSC 520/540/560AOV CONTROL UNIT

D E S C R I P T I O N

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

I N P U T S F O RManual Override Switch

Smoke Sensor

Fire Alarm

Switch

Thermostat

Wind Sensor

Rain Sensor

BMS (BACnet or KNX)

A P P L I C A T I O N

SMOKEVENTILATION

C E R T I F I C A T I O N

V O L T A G EInput = 230V AC, Output = 24V DC

M O T O R L I N E S M O T O R L O A D1 - 39 20 A (WSC 520) 40 A (WSC 540)

60 A (WSC 560)

For heat and smoke ventilation (H&S) and daily comfort ventilation

Only one type of group (each group can be set as H&S and/or natural ventilation)

Low power consumption

20A, 40A or 60A as standard per panel, more panels can easily be linked without any additional modules

For both ±24V standard motors and/or motors with MotorLink®

Easy con�guration via the built-in touch screen

Less cabling as the panel uses bus technology

Wind direction depending H&S ventilation is standard additional modules are not needed

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

Elec

tric

/ Sm

oke

Vent

iltat

ion

/ Con

trol

Uni

ts

D E S C R I P T I O N ( C O N T I N U E D )

WSC 520/540/560AOV CONTROL UNIT

Modular smoke ventilation panel for the control of ±24V DC motors and motors with MotorLink® for smoke ventilation and daily comfort ventilation. The modular panel can be used in larger and medium sized buildings e.g. shopping centres, schools or sport/leisure facilities. Comfort ventilation also possible with KNX or BACnet IP due to bus technology together with eg. NV Comfort® or NV Advance®.

By linking several panels together the panels can be used in very large buildings. The linking of panels can be carried out from the beginning or later via CAN. Distance between two smoke control panels up to 250m with maximum total distance of 1000m.

Built-in uninterruptible power supply for min. 72h in case of power loss (batteries are to be ordered separately).

Special technical featuresapproval according to EN 12101-10approval according to prEN 12101-9 requestedautomatically limited opening for comfort ventilation without additional modules�eld bus modules are available for KNX and BACnet IPmax. output voltage 27.6VDC @230VACmodular plug-in card design�exible open system designsimple installation – due to substantially less cablingeasy con�guration at start up / expanding / rebuilding on the 3½” LCD built in touch screen in the panel – this can also be done on a PC without any additional modulesthe touch screen is also used for quick troubleshooting when maintaining the system

Connection optionstriggering by BMS via potential-free contact without any additional modulesone ±24V DC standard motor line up to 20A in the WSA 5PS module without additional modules or up to 10A per motor line (standard motors and/or motors with MotorLink®) on the motor modules, max. total of 20A per sectionup to 30 break glass units per 20A section, 10 of the units can be connected with a smoke detector – up to 10 detectors per unitmagnetic clamps – for further information see the installation instruction

SectionsThe FlexiSmoke™ smoke ventilation panel is available in three di�erent sizes 20A, 40A and 60A. The smoke ventilation panel consists of 20A-sections, thus WSC 520 contains one section, WSC 540 two sections and WSC 560 three sections.

ModulesEach section contains the WSA 5PS power supply module, the WSA 5MC overall control module and 3 slots for expansion modules. The WSA 5MC overall control module is available with or without �eld bus interface for KNX or BACnet IP.

At the 3 slots the WSA 5IO input/output module, the WSA 5SM ± 24V standard motor module or the WSA 5ML MotorLink® motor module can be connected. The type and number of the modules are speci�cally to suit the smoke panel required function.

Motor groups and motor linesA motor group consists of one or more motor lines and all the motor lines are operated simultaneously.

Each 20A section contains one 20A motor line for connection of ±24V standard motors on the WSA 5PS module. If more motor lines are needed, one or more motor modules WSA 5SM are inserted. Each motor module contains four motor lines.

For connection of motors with MotorLink® insert one or more motor modules WSA 5ML. Each motor module contains four motor lines.

It is possible to insert both motor module types in the same 20A section, thus the section will operate both ±24V standard motors and motors with MotorLink®.

A 20A-section can contain up to 13 ±24V standard motor lines or 12 MotorLink® motor lines as well as 1 ±24V standard motor line. The total power consumption of all the motors must not exceed 20A.

Elec

tric

/ Sm

oke

Vent

ilati

on /

Cont

rol U

nits

29 30

Page 16: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

WSC520 0IS0Control Unit (5 motorlines)

WLA 331Rain Sensor

230V AC Mains Power FIRE ALARM

Zone

1H

ead

of S

tairw

ell A

OV

Zone

21s

t Flo

or C

orrid

or A

OV

Zone

32n

d Fl

oor C

orrid

or A

OV

Zone

43r

d Fl

oor C

orrid

or A

OV

Zone

5H

ead

of S

mok

e Sh

aft A

OV

Manual CallpointWSK 501

WSC 520 / 540 / 560

CONNECTIONS

Elec

tric

/ Sm

oke

Vent

ilati

on /

Cont

rol U

nitsT E C H N I C A L D A T A

Primary Voltage (Input) 230V AC

Secondary Voltage (Output) 24V DC

Motor Load 20 A (WSC 520), 40 A (WSC 540) or 60 A (WSC 560)

Motor Lines 1 - 39

Inputs Manual Override Switch, Smoke Sensor, Fire Alarm, Switch, Thermostat, Wind Sensor, CO2, Rain Sensor, BMS (BACnet or KNX)

Operating Condition -5°C - +40°C

Battery Backup 72 hr

Size 380 x 600 x 210 mm (WSC 520), 600 x 600 x 210 mm (WSC 540) or 1000 x 760 x 210 mm (WSC 560)

Protection Type IP 54

Delivery 1 x Control Unit & Batteries

Battery Size 12V 18Ah

EN 12101-10Certification

www.tealproducts.com+44 (0)1242 [email protected]

If you require any further assistance please do not hesitate to contact our sales team.

Elec

tric

/ Sm

oke

Vent

ilati

on

/

Con

trol

Uni

ts

WSC 520/540/560AOV CONTROL UNIT

NV SOLO - Control Unit & Weather Station

SSR-D - Optical Smoke Sensor

WCA3FB - Fieldbus card BACnet-IP key

WCA3FK - Fieldbus card KNX interface

WCA3FM - Fieldbus card BACnet/MSTP interface

WLA110 - Room Thermostat

WLA150 - Co2 & Temperature Sensor

WLA330 - Wind & Rain Sensor

WLA331 - Rain Sensor

WSK100 - Ventilation Keypad

WSK501 - Manual Override Switch

WSK503 - Manual Override Switch

A C C E S S O R I E S P A R T C O D E S

20 A

20 A

20 A

20 A

40 A

40 A

40 A

40 A

40 A

40 A

40 A

60 A

60 A

60 A

60 A

60 A

60 A

60 A

60 A

60 A

1

5

9

13

6

2

14

10

18

22

26

11

19

19

15

23

27

35

31

39

1

Motor Load Motor Lines Inputs

5

6

4

9

20

14

10

12

10

8

11

22

19

15

17

18

14

10

12

WSC 520 0000 E1

WSC 520 0IS0 E1

WSC 520 0ISS E1

WSC 520 0SSS E1

WSC 540 0I00 0IS0 E1

WSC 540 0III 0III E1

WSC 540 0IIS 0ISS E1

WSC 540 0IS0 0IS0 E1

WSC 540 0ISS 0ISS E1

WSC 540 0ISS 0SSS E1

WSC 540 0SSS 0SSS E1

WSC 560 0I00 0IS0 0S00 E1

WSC 560 0IIS 0IIS 0ISS E1

WSC 560 0IIS 0ISS 0IS0 E1

WSC 560 0IS0 0IS0 0IS0 E1

WSC 560 0IS0 0ISS 0ISS E1

WSC 560 0ISS 0ISS 0ISS E1

WSC 560 0ISS 0SSS 0SSS E1

WSC 560 0S00 0SSS 0SSS E1

WSC 560 0SSS 0SSS 0SSS E1

*More versions available depending on application.

31 32

Page 17: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

ACCESSORIES

P R O D U C T C O M P A R I S O N

A C C E S S O R I E S

Code egaP

Break Glass Callpoint

Firemans Override Switch

Firemans Override Key Switch

1

1

1

BG1/S

BG1/FOS

BG2/FOS

VCS-S2

WSC 204

WSC 520/540/560

Compatible with

Description

Wind & Rain Sensor

Rain Sensor

Manual Callpoint

1

1

1

WLA 330

WLA 331

WSK 320

Smoke Sensor 1SSR-D

Manual Callpoint 1WSK 501

P R O D U C T C O M P A R I S O N

33

35

35

35

35

35

35

35

35

34

Page 18: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

If yo

u re

quire

any

furt

her a

ssis

tanc

e pl

ease

do

not h

esita

te to

con

tact

our

sal

es te

am.

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 24V DC

Operating Condition -10°C - +55°C

Size 89 x 93 x 59.50 mm

Protection Type IP 24D

Delivery 1 x Breakglass Callpoint, 1 x Resettable Element & 1 x Surface Mount Box

Cable Size 2-Core

BG1/SBRE A KG LAS S CALLPO INT

D E S C R I P T I O N Breakglass Callpoint for manual open/close operation smoke AOV. Compatible with VCS-S2 smoke control unit. Supplied with back box for surface mounting.

BG1/SBREAKGLASS CALLPOINT

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

BG1/SBR EAK GL ASS C AL L P OINT

P A R T C O D E S A C C E S S O R I E S

SMOKEVENTILATION

A P P L I C A T I O N C O M P A T I B L E W I T H

VCS-S2 - Control Unit

BG1/S/O - BG1/S Breakglass Callpoint Orange BG1/C - Protective Cover

BG1/GLASS - Replacement Glass 40 x 71 mm (5 pcs)

BG1/RE - Resettable Element Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

ACCESSOR IES

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 18-24V DC

Operating Condition -20°C - +60°C

Size 100 x 42 mm

Protection Type IP 23D

Delivery 1 x Smoke Sensor & 1 x Diode Base

Cable Size 2-Core

SSR-DSMO KE SENSOR

D E S C R I P T I O N Optical sensor for the automatic opening/closure of windows and rooflights in the event of smoke detection. Compatible with most smoke control units. When smoke is detected the sensor will automatically send a signal to the actuator (via control unit). Supplied complete with diode base.

SSR-DSMOK E SENSOR

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

DESCRIPTION 24V sensor for the automatic closure of windows and light domes in the case of wind/rain complete with mounting brackets for direct control of smoke ventilation units and control units. The wind/rain sensor comprises an anomemeter and a rain sensor surface. The wind/rain sensor can be activated by a change-over-contact.. Measurement for wind: via wind wheel m/s. Measurement for rain: conductivity measurement on the heated sensor surface. The settings sensitivity and the delay are changeble. The settings for the for sensor, for the wind trigger threshold, the activation delay, the drop out delay and the trip in the event of a mains failure are made by a six pole DIP switch in the sensor.

Electric / Comfort Ventilation

/ Accessories

TECHNICAL DATA

Primary Voltage20 - 32V DC

Size80 x 160 x 55 mm

Protection TypeIP 65

Delivery1 x Wind & Rain Sensor & 1 x Mounting Bracket

Cable Size4-Core

WLA 330WIND & RAIN SENSOR

WLA 330WIND & RAINSENSOR

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

WLA 331RAIN SENSOR

D E S C R I P T I O N 24V sensor for the automatic closure of windows and light domes in the case of wind/rain complete with mounting brackets for direct control of smoke ventilation units and control units. The rain sensor comprises a rain sensor surface. The rain sensor can be activated by a change-over-contact. Measurement principle for rain: conductivity measurement on the heated sensor surface.

Elec

tric

/ Co

mfo

rt V

enti

lati

on

/ Ac

cess

orie

s

T E C H N I C A L D A T A

Primary Voltage 20 - 32V DC

Size 80 x 80 x 55 mm

Protection Type IP 65

Delivery 1 x Rain Sensor & 1 x Mounting Bracket

Cable Size 4-Core

WLA 331RAIN SENSOR

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 24V DC

Operating Condition -10°C - +55°C

Size 89 x 93 x 59.50 mm

Protection Type IP 24D

Delivery 1 x Breakglass Callpoint, 1 x Resettable Element & 1 x Surface Mount Box

Cable Size 2-Core

BG1/SBRE AKGL ASS CA LLPOINT

D E S C R I P T I O N Breakglass Callpoint for manual open/close operation smoke AOV. Compatible with VCS-S2 smoke control unit. Supplied with back box for surface mounting.

BG1/SB REAKG LAS S CALLPO INT

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 24V DC

Operating Condition -10°C - +55°C

Size 87 x 87 x 52 mm

Protection Type IP 24D

Delivery 1 x Manual Override Switch, 1 x Protective Cover & 1 x Surface Mount Box

Cable Size 3-Core

BG1/FOSOVERRIDE SWITCH

D E S C R I P T I O N Manual override switch for manual open or close operation smoke AOV. Compatible with VCS-S2 smoke control unit. Supplied with protective cover and back box for surface mounting.

BG1/FOSOVERRIDE SWITCH

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com+44 (0)1242 [email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 24V DC

Operating Condition -10°C - +55°C

Size 87 x 87 x 52 mm

Protection Type IP 24D

Delivery1 x Manual Override Switch,

1 x Protective Cover, 1 x Surface Mount Box & 2 x Keys

Cable Size 3-Core

BG2/FOSOVERRIDE KEY SWITCH

D E S C R I P T I O N Manual override key switch for manual open or close operation smoke AOV. Compatible with VCS-S2 smoke control unit. Supplied with protective cover and back box for surface mounting.

BG2/FOSOV ER R I D E KEY SWI T C H

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com

+44 (0)1242 620318

[email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage24V DC

Size125 x 125 x 36 mm

Protection TypeIP 40

Delivery1 x Manual Override Switch, 1 x Key &

1 x Glass Piece

Cable Size 6-Core (WSK 320) or 3-Core (WSK 330)

WSK 320/330OVERRIDE SWITCH

D E S C R I P T I O N

For manual activation of smoke ventilation

system. Break glass unit with the highest priority

in smoke ventilation panels. Lockable housing in

plastic or metal. Surface mounting. Spare parts

(glass, keys etc.) can be ordered separately.

WSK 320/330OVERRIDE SWITCH

If you require any further assistance please do not hesitate to contact our sales team.

www.tealproducts.com

+44 (0)1242 620318

[email protected]

Elec

tric

/ Sm

oke

Vent

ilati

on /

Acce

ssor

ies

T E C H N I C A L D A T A

Primary Voltage 24V DC

Size 125 x 125 x 36 mm

Protection Type IP 40

Delivery1 x Manual Override Switch,

1 x Key & 1 x Glass Piece

Cable Size 3-Core

WSK 501/503OVERRIDE SWITCH

D E S C R I P T I O N For manual activation of smoke ventilation

system. Break glass unit with the highest priority

in smoke ventilation panels. Lockable housing in

plastic or metal. Surface mounting. Spare parts

(glass, keys etc.) can be ordered separately.

WSK 501/503OVERRIDE SWITCH

WSK 320/330OVERRIDE SWITCH

WSK 501/503OVER R IDE S WITCH

BG1/SBREAKGLASS CALLPOINT

CHAIN ACTUATORSVARI O US S I ZES AVAI LAB LE

LINEAR ACTUATORSVARI O US S I ZES AVAI LAB LE

FOLDING ARM ACTUATORSVARI O US S I ZES AVAI LAB LE

BG1/FOSOVER R IDE S WITCH

BG2/FOSOVER R IDE KEY S WITCH

SSR-DSMOKE SENSOR

WLA 331R A IN S ENS OR

WLA 330WIND & R A IN S ENS OR

C A L L P O I N T S A C T U A T O R S

S E N S O R S SPARESKEY S , GLASS P I ECES , PCB ’S ETC .

35 36

Page 19: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

T R A I N I N G

Interested in learning more about smoke ventilation systems? Teal Products host a free to attend monthly workshop providing product training for professionals installing natural and smoke ventilation systems. The workshop includes both theory and practical training on our extensive range of products. Our purpose-built demonstration room allows engineers to get hands on with the products, allowing them to simulate real scenarios.

E S T I M A T I N G

Need help selecting the correct product(s), help with a quotation or have a technical query? Our experienced and friendly staff are here to help. Full technical support and first-class customer service ensure you are guaranteed the very best response from initial enquiry to installation.

C O M M I S S I O N I N G

Are you looking for someone to commission your smoke ventilation system? Our experienced team of engineers cover the whole of the UK and are on hand to help whatever the size of the project.

SERVICES

37 38

Page 20: SMOKE VENTILATION - Teal Products...VENTS PRODUCT COMPARISON VENTS Code Page AOV Glaed Wall Loure AOV Wall Loure AOV Wall Damper 1 1 1 SV-W-GL SV-W-L SV-W-D Description 24V DC 24V

Teal Products LtdUnit 8A, Orchard Trading Estate,Toddington, Cheltenham,GL54 5EB, UK

www.tealproducts.com+44 (0)1242 [email protected]