Series FGD/FGE/FGG/FGA/FGB/FGCIndustrial Filters
Vessel Series/Elements
FGA type
Sintered metal
FGB type
FGC type
FGG type
Elements
FGE type
Micromesh
Fiber
Paper
Vessel Series
FGD type
751
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SMC industrial filters are
Series Application/Specifications Page
SMC
P.756
P.759
P.762
P.765
P.768
P.771
• Suitable for medium flow rate, low pressure “filtration”.
• Element replacement is easy with the V-band type.(with cover anti-scattering mechanism)
• Can be used with a wide range of fluids.
FGE Series
• Suitable for high flow rate, low pressure “filtration”.
• Element replacement is easy with the V-band type.(with cover anti-scattering mechanism)
FGG Series
• Various types of elements can be selected accord-ing to the “filtration conditions”, and the unit can be used for a wide range of applications.
• This type has a vertical structure, so there is little loss of “filtrate”.
• Maintenance and inspection—element replacement in particular is easy.
• When using with a class 2 pressure vessel, this will be handled as a special order product.
FGA Series (Made to Order)
• Various types of elements can be selected according to the “filtration conditions.”
• The element is of the hanging type, so the structure is suitable for filtration of gases having a large difference in specific gravity from particles, for “filtration” of severely fouled fluids, and for backwash type elements (sintered metal, micromesh).
• During maintenance, the partition plate can be removed together with the element, so internal cleaning and in-spection are easy.
• When using with a class 2 pressure vessel, this will be handled as a special order product.
FGB Series (Made to Order)
• Various types of elements can be selected accord-ing to the “filtration conditions”, and the unit can be used for a wide range of applications.
• This type has a vertical structure, so there is little loss of “filtrate”.
• Maintenance and inspection—element replacement in particular is easy.
FGC Series (Made to Order)
SMCStandard elements can be incorporated
Please use by setting an element
• Suitable for low flow rate, low pressure “filtration”.
• Can be used with a wide range of fluids.
• Antistatic specifications (FGDE, FGDF)
FGD Series
SMC Filters (Vessel Series)
• Application: Low flow rate filtration (Max. 60 l/min)• Specifications: Maximum operating pressure: 0.7, 1 MPa
Port size: Rc3/8, 1/2, 3/4 Body materials: Cover: Aluminum, SCS14 Case: SPCD, Stainless steel 316
• Application: Medium flow rate filtration (Max. 230 l/min)• Specifications: Maximum operating pressure: 0.7 MPa
Port size: R1, 2 Body material: Stainless steel 304
• Application: High flow rate filtration (Max. 350 l/min)• Specifications: Maximum operating pressure: 0.7 MPa
Port size: Rc2 (female) Body material: Stainless steel 304
• Application: High flow rate filtration (Max. 3200 l/min)• Specifications: Maximum operating pressure: 1 MPa
Port size: Flange JIS 10KFF 25 to 150 (1B to 6B)
Body materials: SS400,Stainless steel 304(wetted parts)
• Application: High flow rate filtration (Max.3800 l/min) Filtration of severely fouled fluid
• Specifications: Maximum operating pressure: 1 MPa Port size: Flange JIS 10KFF
25 to 150 (1B to 6B) Body materials: SS400,
Stainless steel 304(wetted parts)
• Application: Low flow rate filtration (Max. 80 l/min) Filtration of high-pressure fluid
• Specifications: Maximum operating pressure: 1, 2, 4 MPa Port size: Flange JIS 10KFF (FGC1)
15 to 25 (1/2B to 1B) JPI300LbRF (FGC2) JPI600LbRF (FGC4)
Body materials: SS400,Stainless steel 304(wetted parts)
752
P.774
Element Series
EB
ES
EH
EHM
EHK
EP
EM100
EM500
Material Page
Bronze
Nominal filtration accuracy (µm)
Stainless steel 316
Stainless steel 316(Nickel brazing)
1, 2, 5, 1020, 40, 70100, 120
1, 2, 5, 1020, 40, 70100, 120
Main applications
All types of gases/liquids,General solvents,
High-temperature fluids
P.775
Stainless steel 304(Epoxy adhesion)
5, 10, 20, 4074, 105
5, 10, 20, 4074, 105
All types of gases/liquids,High-temperature fluids
P.775Cotton,
Phenol impregnated,Epoxy adhesion
5, 10, 20Hydraulic oil,
Lubricating oil,Fuel oil
P.774
Cotton0.5, 1, 5, 10
20, 50, 75, 100
Polypropylene0.5, 1, 5, 10
20, 50, 75, 100
Glass fiber 1, 5, 10, 20
General solvents,General neutral fluids
Plating fluids, General acids,Alkali fluids, Industrial water,
Cooling water
Acidic fluids,High-temperature fluids
Sintered metal
active in all fields of industry.into any type of vessel for SMC filters.suited to the application in the vessel.
Fiber (Honeycomb)
Paper
Micromesh
Standard Elements
FiltersFilters
753
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Filter Selection by Main ApplicationFGD/FGE/FGG type
FGD type FGE typeFGG type
Fluid name Applicable elementtype, material
Nominalfiltrationaccuracy
(µm)
Applicable filter model
Field of use
Industrial water
Municipal water for cleaning
Carbon dioxide
Air (Dry)
Industrial water
Municipal water for cleaning
Air (Dry)
Water
Fragrances
Air (Dry)
Hot water
Air (Dry)
General solvents
Air (Dry)
Grinding fluid (Grinding machines)
Grinding fluid (Oilstone)
Lubricating oil
Cooling water
Air (Dry)
Cleaning water
Developing fluid
Fixing solution
Air (Dry)
Air (Dry)
Nitrogen gas
Carbon dioxide
Lacquer
Air (Dry)
10
20
10
0.5 to 10
10
20
0.5 to 10
20
10
0.5 to 10
10
10
40
0.5 to 10
10
10
10
50
0.5 to 10
1 to 10
10
10
0.5 to 10
0.5 to 10
10
10
50
0.5 to 10
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Food industryBrewing industry
Pharmaceuticalindustry
Cosmeticsindustry
Washingequipment
industry
Syntheticdetergentindustry
Machinetool related
Photo industryElectronicequipment
industry
Instrumentationindustry related
Painting related
FGDC
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGDE
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGDT
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGDF
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGES
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGEL
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGET
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGGS
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
FGGL
Note) Please refer to “How to Order” for each series when a filter vessel is combined with an element.
�: Recommended �: Can be used �: Cannot be used
Fiber elementPolypropyleneFiber elementPolypropyleneFiber element
CottonFiber element
CottonFiber elementPolypropyleneFiber elementPolypropyleneFiber element
CottonFiber elementPolypropyleneFiber element
CottonFiber element
CottonMicromesh elementStainless steel 316
Fiber elementCotton
Micromesh elementStainless steel 316
Fiber elementCotton
Fiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber elementPolypropyleneFiber element
CottonFiber element
CottonFiber element
CottonFiber element
CottonFiber element
Cotton
754Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Note 1) Indicates flow rate in l/min under atmospheric pressure (ANR) (at 0.5 MPa).Note 2) Gases cannot be used.Note 3) Please consult SMC for high flow rates other than the above.
Air(Dry)
0.5 Note 1)
110
110
110
200
200
210
410
410
800
800
1100
1200
—
—
—
10 Note 1)
550
750
1000
600
840
1200
3000
3600
3300
4200
3400
4400
—
—
—
1
11
12
13
17
21
23
45
50
70
90
83
120
160
200
230
5
21
27
32
25
35
46
90
120
140
170
150
190
270
300
320
10
23
30
36
26
37
50
120
140
150
180
160
200
300
320
330
20
26
36
46
28
41
56
140
170
160
210
170
220
320
340
350
10
22
28
32
26
38
50
100
110
120
140
120
150
290
320
330
5
29
42
57
30
44
63
160
210
170
230
170
230
360
370
370
Air(Dry)
WaterMunicipal water
for cleaning,Cooling water
Lubricating oil (20 mm2/s)
Cleaning water Industrial waterFragrances(1 mm2/s)
Cotton Polypropylene Paper Micromesh
FGDCA
FGDEA
FGDTA
FGDFA
FGDCB
FGDEB
FGDTB
FGDFB
FGESA Note 2)
FGELA Note 2)
FGETA
FGESB Note 2)
FGELB Note 2)
FGETB
FGESC Note 2)
FGELC Note 2)
FGETC
03
04
06
03
04
06
10
20
10
20
10
20
Fluid nameApplicable element
Nominal filtration accuracy (µm)Applicable filter model
FGGSB
FGGLB
FGGSC
FGGLC
FGGSD
FGGLD
�How to read the chart
Example)• Application: Scale removal in municipal water for cleaning in the brewing industry• Treatment flow rate: 170 l/M• Nominal filtration accuracy: Left up to the manufacturer• Port size: 2
For the above specifications, first see “Food industry” for “Filter Selection by Main Application”. The applicable element for municipal water for cleaning is polypropylene, with a nominal filtration accuracy of 20 µm, and the applicable filter model are all models except FGDC and DGDE.Next, see "Applicable Filter and Treatment Flow Rate". Follow the item where the fluid name is municipal water for cleaning to the bottom, and at the point where the specifications are 170 l/M or more, see the left. The filter models FGESA, FGELA and FGETA are the applicable filter models.
Therefore, the selected filter model and element are:Filter model = FGESA-20
Element = Polypropylene 20 µm(EHM15R10A)
Filter Selection by Main Application
Applicable Filter and Treatment Flow Rate
*Indicates the flow rate (l/min) when the initial pressure drop (including vessel resistance) is 0.0015 MPa (for gas) or 0.015 MPa (for fluid).
755
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order
Industrial Filter: Vessel Series
Series FGD
FGD C A 03 BB N002
CETF
CoverAluminumAluminum
SCS14SCS14
CaseSPCDSPCD
Stainless steel 316Stainless steel 316
Gasket/O-ringNBRNBR
FluororesinFluororesin
SealNylon
Nylon/FluororesinFluororesin
Fluororesin (Antistatic specifications)
Symbol
Material
AB
Element lengthl250
l500 (l250 x 2)
Symbol
Element length
030406
Port size Rc3/81/23/4
Symbol
Port size
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
MaterialBronze
Stainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
Element category
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm) 0.5
1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
B
AccessoryNone
Bracket
Symbol
Nil
Accessory
X77
X78
DescriptionNone
With differential pressure indicator(For details, refer to page 776)
With differential pressure indication switch (For details, refer to page 776)
Symbol
Nil
Made to Order
• Suitable for low flow rate, low pressure “filtration.”
• Can be used with a wide range of fluids.
• Antistatic specifications (FGDE, FGDF)
Note 1) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.
Note 2) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 3) When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above “How to Order.”
Note 4) Please use industrial filters in combination with parts made by SMC (ves-sels, elements etc.)
Note) For a comparison with the nominal filtration accuracy according to the element category, refer to pages 774 and 775.
756
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Hexagon head boltr SealNute SealCoverw Gasket
Guide
Element
Tension bolt
Joint
Case
q SealWasher
Spring
t Seal
Plug
Holder
Replacement Seal List
No. Description MaterialPart no.
FGDC/FGDE FGDT/FGDFSize
1
2
3
4
5
Seal
Gasket
Seal Note 3)
Seal
Seal
NBRJIS B 2401.P12
Fluororesin
NBR
Fluororesin
Nylon
Fluororesin
Fluororesin (Antistatic specifications)
Nylon
Fluororesin
Nylon
Fluororesin
AL-47S
—
AL-16S
—
AL-50S
—
AL-46S
AL-48S
—
AL-54S
—
—
AL-59S
—
AL-18S
—
AL-45S
AL-46S
—
AL-43S
—
AL-53S
—
—
ø101 x ø86 x t2
—
ø23 x ø16.5 x t1
ø10 x ø6.5 x t1
ø20 x ø14 x t1
Specifications
Model FGDCA
1.3 2.2
Aluminum
SPCD
NBR
Nylon
1
ø65 x l250
2 Note 2)
ø65 x l500(l250 x 2)
1.3 2.2
Aluminum
SPCD
NBR
Nylon/Fluororesin
1
ø65 x l250
2 Note 2)
ø65 x l500(l250 x 2)
2.3 3.8
SCS14
Stainless steel 316
Fluororesin
Fluororesin
1
ø65 x l250
2 Note 2)
ø65 x l500(l250 x 2)
2.3 3.8
SCS14
Stainless steel 316
Fluororesin
Fluororesin
1
ø65 x l250
2 Note 2)
ø65 x l500(l250 x 2)
3/8, 1/2, 3/4
0.7
80
3/8, 1/2, 3/4
0.7
80
3/8, 1/2, 3/4
1
80
3/8, 1/2, 3/4
1
80
Port size (Rc)
Max. operating pressure (MPa) Note 1)
Max. operating temperature (°C)
Number of elements
Element size
Main materials
Mass (kg)
1.7 3.4 1.7 3.4 1.7 3.4 1.7 3.4Internal capacity (l)
Cover
Case
Gasket/O-ring
Seal
FGDCB FGDEA FGDEB FGDTA FGDTB FGDFA FGDFB
Note 1) For gases, 0.5 MPa.Note 2) 1 element (ø65 x l500) in the case of a sintered metal element or paper element.
Note 1) The quantity used for 1 filter is 1 each for the following seals, gaskets and O-rings.Note 2) Replacement seal kit part no.: KT-FGD�
For �, fill in the material symbol in “How to Order” (Refer to page 756). A seal kit contains 1 each of seal/gasket No. 1 to 5.
Note 3) With antistatic specifications (FGDE, FGDF), this will be fluororesin (AL-46S).
Industrial Filter: Vessel Series Series FGD
757
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
205-FGD.qxd 10.6.2 9:45 AM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dimensions
Accessory/Bracket
FGD�A (1 element) FGD�B (2 elements)
∗ Element removal dimension: 50 mm
Model
FGDCFGDE
FGDTFGDF
Element length
A (l250)
B (l500)
A (l250)
B (l500)
Port size Rc
3/8, 1/2, 3/4
A314
574
314
574
B346
606
349
608
(mm)
Part no.
BP-1S
BP-2S
BP-3S
Port size Rc
3/8
1/2
3/4
øA17.5
22
27.5
(mm)63.5
6246
R3.5
118.6108
2.3
92
2210
.5
2-øA
R22
2 x Rc
G1/4
108
AIR VENTM6 x 1
B A
OUTLETINLET
DRAIN
2 x Rc
G1/4
108
AIR VENTM6 x 1
B A
OUTLETINLET
DRAIN
FGDTFGDF
758
Series FGD
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FGE T A 10 B N002
ABC
Element lengthl250
l500 (l250 x 2)l750 (l250 x 3)
Symbol
Element length
1020
Port size R12
Symbol
Port size
BSTGHPML
Element type
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
MaterialBronze
Stainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
Element category
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm)
0.5 1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
Material
TBody
Stainless steel 304Gasket/O-ring
FluororesinSymbol
Material
SL
Body
Stainless steel 304
Gasket/O-ringNBRFKM
Symbol
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
NilG1G2
Pressure gauge typeNone (with plug)
G46-10-02M (Brass at wetted parts)G46-10-02X3 (Stainless steel at wetted parts)
Symbol
Option
FGES/FGEL type(V-band type)
FGET type(Bolt tightening type)
FGET type (Bolt tightening type)
∗ Please use the applicable pressure gauge de-pending on the fluid used.
FGES/FGEL type (V-band type) FGE S A 10 B N A002
Industrial Filter: Vessel Series
Series FGEHow to Order
Note) For a comparison with the nominal filtra-tion accuracy according to the element category, refer to pages 774 and 775.
Note 1) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.
Note 2) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 3) When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above model indication method.
Note 4) Please use industrial filters in combination with parts made by SMC (ves-sels, elements etc.)
Note 5) Do not use the V-band type for gases.
• Suitable for medium flow rate, low pressure “filtration.”
• Element replacement is easy with the V-band type.(with cover anti-scattering mechanism)
• Can be used with a wide range of fluids
759
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AIR VENT
Cover
V-band
O-ring
Filter case
OUTLET
PRESSURE PORT
INLET
DRAIN
PRESSURE PORT
DRAIN
Element
Element guide
Element mounting bracket
Tension bolt
Element retaining plate
Plain washerWing nut
Replacement Parts and Seal List
No. Description
1
2
—
O-ring
Gasket
Case fastening parts
FGESNBR
JIS B 2401-1A-.P185FKM
JIS B 2401-4D-.P185
— —
V-band coupling(Part no.: CY-24S)
Hexagon head boltM12 x 4 pcs.
Fluororesinø194 x ø188 x t2
(Part no.: AL-19S)
—
FGELMaterial
FGET
Note) The quantity used for 1 filter is 1 each of the above O-ring and gasket etc. Four hexagonal bolts are used for 1 filter.
Model
4
ø65 to 70x l250
NBR —FKM
Stainless steel 304
Stainless steel 304
1, 2
0.7
80
1, 2
0.7
80
1, 2
0.7
80
Port size (R)
Max. operating pressure (MPa)
Max. operating temperature (°C)
Number of elements
Element size
Mainmaterials
Mass (kg)
Internal capacity (l)
Cover
Case
Gasket
O-ring
Legs
FGESA Note 1)
4
ø65 to 70x l250
FGELA Note 1)
4 Note 2)
ø65 to 70x l500
8
ø65 to 70x l250
FGESB Note 1)
4 Note 2)
ø65 to 70x l750
12
ø65 to 70x l250
FGESC Note 1)
4
ø65 xl250
FGETA
4 Note 2)
ø65 to 70x l500
8
ø65 to 70x l250
FGELB Note 1)
4 Note 2)
ø65 to 70x l750
12
ø65 to 70x l250
FGELC Note 1)
4 Note 2)
ø65 xl500
8
ø65 xl250
FGETB
4 Note 2)
ø65 xl750
12
ø65 xl250
FGETC
— —— — Fluororesin— — Fluororesin Fluororesin
10
14
10
14
13
21
18
29
12
11.5
13
21
18
29
15
18.5
20
26
Note 1) Cannot be used with gases.Note 2) In the case of a sintered metal element or paper element.
SS400 (Chromatic plating)
Specifications
760
Series FGE
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dim
ensi
on r
equi
red
for
cove
r re
mov
al
203
90
G1/4
AIRVENT
OUTLETINLET
DRAIN
ø188
R3/4
2 x R
260
AB
C
OUTLETINLET
4 x ø15For M12 foundationbolt
AIR VENTDRAIN
ø240
0°315°
270°
225°180°
135°
90°
45°
ORIENTATION
G1/8
DRAIN
2 x R
R3/4
Rp1/4
Rp1/4
INLET
OUTLET
DRAIN
R3/4
AIR VENT
ø189
260
90
203
348
AB
C D
imen
sion
req
uire
d fo
r re
mov
al
FGES/FGEL type (V-band type) FGET type (Bolt tightening type)
FGES type (V-band type)Model
FGESAFGESBFGESC
A
554
B 671
931
1191
C 850
1325
1825
Port size R
1, 2
(mm) FGEL type (V-band type)Model
FGELAFGELBFGELC
A
554
B 671
931
1191
C 850
1325
1825
Port size R
1, 2
(mm) FGET type (Bolt tightening type) Model
FGETAFGETBFGETC
A366
516
647
B 612
871
1225
C 910
1225
1620
Port size R
1, 2
(mm)
Dimensions
Industrial Filter: Vessel Series Series FGE
761
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FGG S B 20 B N002
BCD
Element lengthl500 (l250 x 2)l750 (l250 x 3)l1000 (l250 x 4)
Symbol
Element length
20Port size Rc
2Symbol
Port size
Material
SL
BodyStainless steel 304Stainless steel 304
O-ringNBRFKM
Symbol
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
MaterialBronze
Stainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
Element category
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm) 0.5
1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
NilG1G2
Pressure gauge typeNone (with plug)
G46-10-02M (Brass at wetted parts)G46-10-02X3 (Stainless steel at wetted parts)
Symbol
Option
∗ Please use the applicable pressure gauge de-pending on the fluid used.
A
Industrial Filter: Vessel Series
Series FGGHow to Order
Note) For a comparison with the nominal filtra-tion accuracy according to the element category, refer to pages 774 and 775.
• Suitable for high flow rate, low pressure “filtration.”
• Element replacement is easy with the V-band type. (with cover anti-scattering mechanism)
Note 1) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.
Note 2) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 3) When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above “How to Order”.
Note 4) Please use industrial filters in combination with parts made by SMC (ves-sels, elements etc.)
Note 5) Do not use this filter for gases.
762
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
PRESSURE PORT
DRAIN
PRESSURE PORT
INLET
AIR VENT
OUTLET
Filter case
O-ring
V-band
Cover
Element
Element guide
Element mounting bracket
Tension bolt
Element retaining plate
Flat washer
Wing nut
Model
7 Note 2)
ø65 xl 500
19.5
27
23
43
NBR
30
52
19.5
27
23
43
FKM
30
52
14
ø65 xl 250
7 Note 2)
ø65 xl 750
21
ø65 xl 250
7 Note 2)
ø65 xl 1000
28
ø65 xl 250
7 Note 2)
ø65 xl 500
14
ø65 xl 250
7 Note 2)
ø65 xl 750
21
ø65 xl 250
7 Note 2)
ø65 xl 1000
28
ø65 xl 250
Stainless steel 304
Stainless steel 304
2
0.7
80
2
0.7
80
Note) The quantity used for 1 filter is 1 each of the above O-ring etc.
Port size (Rc)
Max. operating pressure (MPa)
Max. operating temperature (°C)
Number of elements
Element size
Mainmaterials
Mass (kg)
Internal volume (l)
Cover
Case
O-ring
Legs
FGGLD Note 1)FGGLC Note 1)FGGLB Note 1)FGGSD Note 1)FGGSC Note 1)FGGSB Note 1)
Note 1) Cannot be used with gases.Note 2) In the case of a sintered metal element or paper element.
No. Description
1
—
O-ring
Case fastening parts
FGGSNBR
(Part no.: AL-25S)
V-band coupling (Part no.: CY-27S)
FKM(Part no.: AL-22S)
FGGLMaterial
Specifications
Replacement Parts and Seal List
SS400 (Chromatic plating)
Industrial Filter: Vessel Series Series FGG
763
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DRAININLET
3 x ø15For M12 foundation boltAIR VENT
OUTLET
ø197
0°
270°
180° 150°
90°
30°
ORIENTATION
Rp1/4
Rp1/4
Rc2
Rc2
R3/4
DRAIN
INLET
AIR VENT
G1/8
OUTLET
ø214
155 145
360
190
440
AB
C D
imen
sion
req
uire
d fo
r re
mov
al
Model
FGGSCFGGLC
FGGSBFGGLB
FGGSDFGGLD
A
879
1146
1416
B
1065
1332
1602
C∗
1180 to1415
1440 to1930
1710 to2450
(mm)
∗ The “C” dimension varies depending on the length of the incorporated element.
Dimensions
Series FGG
764Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FGA C A 1004 B N002
ABCD
Element length
l250l500 (l250 x 2)l750 (l250 x 3)l1000 (l250 x 4)
Symbol
Element length
04070918222934375383
Number of arranged elements 4 7 918222934375383
Symbol
Number of arranged elements
10142024304060
Port size 25 (1B)
40 (1 1/2B)
50 (2B)
65 (2 1/2B)
80 (3B)
100 (4B)
150 (6B)
Symbol
Port size
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm)
0.5 1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
Element category
Vessel material (wetted parts)
CS
Vessel material (wetted parts)SS400
Stainless steel 304
Symbol
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
MaterialBronze
Stainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
Industrial Filter: Vessel Series
Series FGAHow to Order
Note) The connection method is JIS 10KFF flange con-nection.
Note) For a comparison with the nominal filtra-tion accuracy according to the element category, refer to pages 774 and 775.
• Various types of elements can be selected ac-cording to the “filtration conditions,” and the unit can be used for a wide range of applica-tions.
• This type has a vertical structure, so there is lit-tle loss of “filtrate.”
• Maintenance — element replacement in particu-lar is easy.
• When using with a class 2 pressure vessel, this will be handled as a special order product.
Note 2) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.
Note 3) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 4) When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above “How to Order”.
Note 5) Please use industrial filters in combination with parts made by SMC (vessels, elements etc.)
(Necessary numberof elements) = x
(Number of arranged elements)
(Necessary number of elements) = 7 x = 14
Calculation example) If the number of arranged elements is 7, the element length is l 500, and length per element is l 250, then:
(Element length)(Length per element)
500250
Note 1)
765
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Element mounting figureOUTLET
AIR VENT
INLET
DRAIN
BACKWASH
Construction
Applicable Element SpecificationsDescription Material Nominal filtration accuracy (µm) Size
Sintered metalBronze
Stainless steel 316
Cotton (Phenol)
Cotton
Polypropylene
Glass fiber
Stainless steel 304
Stainless steel 316
1, 2, 5, 10, 20, 4070, 100, 120
5, 10, 20
0.5, 1, 5, 10, 2050, 75, 100
1, 5, 10, 20
5, 10, 20, 4074, 105
ø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
ø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
ø65 x l 250
ø65 x l 250
Paper
Fiber (Honeycomb)
Micromesh
Standard SpecificationsModel FGA
1
80
Flange JIS 10KFF 25 to 150 (1B to 6B) Note)
SS400/Stainless steel 304
Non-asbestos
Max. operating pressure (MPa)
Max. operating temperature (°C)
Port size
Vessel material (wetted parts)
Gasket
Note) JIS B 2220 (Steel Welding Pipe Flanges) is used for this flange.
Specifications
766
Series FGA
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
767
AIRVENT
INLET
OUTLET
DRAIN
HF
E
N
N
GD J
AøB
øC
Rc3/8
BACKWASH
WK
Dimensions
Industrial Filter: Vessel Series Series FGA
OUTLET INLET
3 x øPFoundation bolt
AIR VENT
DRAIN
BB.C.D
0°
270°
225°180°
150°
90°
30°
ORIENTATION
Name plate
BA
CK
WA
SH
Number ofarrangedelements
Standard Models
Model N (Port size) G W A øB øC D E F H J K
FGACFGAS
4
4
4
4
7
7
7
9
9
9
18
18
18
22
22
22
29
29
29
34
34
37
37
53
53
83
83
Elementlength (l )
250
500
750
1000
500
750
1000
500
750
1000
500
750
1000
500
750
1000
500
750
1000
750
1000
750
1000
750
1000
750
1000
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
50 (2B)
50 (2B)
50 (2B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
80 (3B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
100 (4B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
150 (6B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
25 (1B)
25 (1B)
25 (1B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
20 (3/4B)
25 (1B)
25 (1B)
25 (1B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
500
500
500
500
570
570
570
620
620
620
720
720
720
760
760
760
820
820
820
870
870
920
970
970
970
1120
1120
330
330
330
330
400
400
400
445
445
445
560
560
560
620
620
620
675
675
675
745
745
795
795
845
845
1020
1020
216.3
216.3
216.3
216.3
267.4
267.4
267.4
318.5
318.5
318.5
400
400
400
450
450
450
500
500
500
550
550
600
600
650
650
800
800
230
230
230
230
230
230
230
240
240
240
270
270
270
270
270
270
300
300
300
300
300
300
300
300
300
300
300
490
490
490
490
510
510
510
560
560
560
710
710
710
720
720
720
850
850
850
860
860
880
880
890
890
950
950
660
905
1160
1415
915
1175
1440
935
1195
1460
1045
1305
1570
1055
1315
1580
1120
1380
1640
1390
1650
1410
1670
1420
1680
1485
1745
965
1220
1485
1750
1250
1510
1775
1290
1550
1815
1445
1705
1970
1455
1715
1980
1575
1835
2095
1845
2105
1865
2125
1880
2140
1950
2210
80
80
80
80
100
100
100
100
100
100
100
100
100
100
100
100
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
150
150
150
150
150
150
150
150
150
150
150
150
250
250
250
250
250
250
250
250
250
250
250
Mass(kg)
70
80
90
105
115
130
150
150
175
200
260
295
340
330
380
430
375
435
495
560
635
630
710
735
830
1180
1330
Internalvolume
(l )
15
24
32
41
37
50
64
54
73
92
103
137
171
131
173
217
163
216
269
262
326
317
394
373
462
597
733
øP
20
20
20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
Note) For the filter body diameter (øC), values of ø400 or higher indicate the inner diameter.
(mm)
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FGB C A 1004 B N002
ABCD
Element lengthl250
l500 (l250 x 2)l750 (l250 x 3)l1000 (l250 x 4)
Symbol
Element length
0407131930365583
Number of arranged elements 4 7131930365583
Symbol
Number of arranged elements
10142024304060
Port size 25 (1B)
40 (1 1/2B)
50 (2B)
65 (2 1/2B)
80 (3B)
100 (4B)
150 (6B)
Symbol
Port size
Industrial Filter: Vessel Series
Series FGBHow to Order
Vessel material (wetted parts)
CS
Vessel material (wetted parts)SS400
Stainless steel 304
Symbol
Note) The connection meth-od is JIS 10KFF flange connection.
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm) 0.5
1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
Note) For a comparison with the nominal filtra-tion accuracy according to the element category, refer to pages 774 and 775.
Element category
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
Material
BronzeStainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
• Various types of elements can be selected according to the “filtration conditions.”
• The element is of the hanging type, so the structure is suitable for filtration of gases having a large difference in specific gravity from particles, for “filtration” of severely fouled fluids, and for backwash type ele-ments (sintered metal, micromesh).
• During maintenance, the partition plate can be removed together with the element, so internal cleaning and inspection are easy.
• When using with a class 2 pressure vessel, this will be handled as a special order product.
Note 2) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.
Note 3) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 4) When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above “How to Order”.
Note 5) Please use industrial filters in combination with parts made by SMC (ves-sels, elements etc.)
Note 1) (Necessary numberof elements) = x
(Number of arranged elements)
(Element length)(Length per element)
(Necessary number of elements) = 7 x = 14
Calculation example) If the number of arranged elements is 7, the element length is l 500, and length per element is l 250, then:
500250
768
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Applicable Element SpecificationsDescription Material Nominal filtration accuracy (µm) Size
Sintered metalBronze
Stainless steel 316
Cotton (Phenol)
Cotton
Polypropylene
Glass fiber
Stainless steel 304
Stainless steel 316
1, 2, 5, 10, 20, 4070, 100, 120
5, 10, 20
0.5, 1, 5, 10, 2050, 75, 100
1, 5, 10, 20
5, 10, 20, 4074, 105
ø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
ø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
ø65 x l 250
ø65 x l 250
Paper
Fiber (Honeycomb)
Micromesh
Standard SpecificationsModel FGB
1
80
Flange JIS 10KFF 25 to 150 (1B to 6B) Note)
SS400/Stainless steel 304
Non-asbestos
Max. operating pressure (MPa)
Max. operating temperature (°C)
Port size
Vessel material (wetted parts)
Gasket
Note) JIS B 2220 (Steel Welding Pipe Flanges) is used for this flange.
Construction
Specifications
Industrial Filter: Vessel Series Series FGB
Element mounting figure
OUTLET
AIR VENT
INLET
DRAIN
BACKWASH
769
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dimensions
OUTLET INLET
3 x øP Foundation boltAIR VENT
BB.C.D
0°
270°
330°
180°150°
90°
ORIENTATION
Name plate
DRAIN
30°
BACKWASH
Davit mounting position
AIRVENT
INLET
OUTLET
DRAIN
HK
FE
N
N
W
G
D J
AøB
øC
Rc3/8
BACK-WASH
Davit
Note) For the filter body diameter (øC), values of ø350 or higher indicate the inner diameter.
Standard ModelsNumber ofarrangedelements
Model N (Port size) G W A øB øC D E F H J K
FGBCFGBS
4
4
4
4
7
7
7
13
13
13
19
19
19
30
30
30
36
36
55
55
83
83
Elementlength (l )
250
500
750
1000
500
750
1000
500
750
1000
500
750
1000
500
750
1000
750
1000
750
1000
750
1000
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
65 (2 1/2B)
—
65 (2 1/2B)
—
65 (2 1/2B)
—
65 (2 1/2B)
—
65 (2 1/2B)
—
65 (2 1/2B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
—
80 (3B)
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
50 (2B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
100 (4B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
—
150 (6B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
80 (3B)
80 (3B)
25 (1B)
25 (1B)
25 (1B)
25 (1B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
40 (1 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
65 (2 1/2B)
80 (3B)
80 (3B)
620
620
620
620
660
660
660
770
770
770
820
820
820
920
920
920
970
970
1080
1080
1230
1230
445
445
445
445
490
490
490
620
620
620
675
675
675
795
795
795
845
845
970
970
1120
1120
318.5
318.5
318.5
318.5
ø350
350
350
450
450
450
500
500
500
600
600
600
650
650
750
750
900
900
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
730
990
1250
1510
1000
1260
1520
960
940
1220
1200
1480
1430
1010
980
1270
1240
1530
1470
1000
940
1260
1200
1490
1460
1280
1220
1510
1480
1260
1220
1490
1480
1280
1230
1510
1490
910
1170
1430
1690
1180
1440
1700
1190
1250
1450
1570
1710
1740
1240
1290
1500
1550
1760
1780
1310
1340
1570
1600
1800
1860
1590
1620
1820
1880
1590
1620
1820
1880
1630
1660
1860
1920
1180
1440
1700
1960
1460
1720
1980
1505
1615
1765
1875
2025
2105
1555
1665
1815
1925
2075
2155
1685
1765
1945
2025
2175
2285
1970
2050
2200
2310
1980
2060
2210
2320
2045
2125
2275
2385
210
210
210
210
230
230
230
290
290
290
320
320
320
360
360
360
390
390
440
440
520
520
—
—
3770
4030
—
3785
4045
3065
3175
3825
3935
4085
4165
3115
3225
3875
3985
4135
4215
3245
3325
4005
4085
4235
4345
4025
4105
4255
4365
4030
4110
4260
4370
4140
4220
4370
4480
Mass(kg)
140
160
260
290
230
340
370
400
400
450
460
500
510
460
480
520
530
560
580
780
800
890
910
950
980
980
1000
1060
1090
1300
1330
1420
1450
1970
2010
2130
2180
Internalvolume
(l )
52
71
90
109
94
119
144
160
177
201
219
242
255
198
220
249
271
300
316
320
343
394
416
459
490
464
490
540
577
623
658
725
773
909
960
1055
1125
øP
20
20
20
20
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
(mm)
770
Series FGB
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
FGC 1 A 04C B N002
AB
Element lengthl250
l500 (l250 x 2)
Symbol
Element length
124
Maximum operating pressure1 MPa2 MPa4 MPa
Symbol
Maximum operating pressure
040610
Port size15 (1/2B)
20 (3/4B)
25 (1B)
Symbol
Port size
Element category
Industrial Filter: Vessel Series
Series FGCHow to Order
Vessel material (wetted parts)
CS
Vessel material (wetted parts)SGP
Stainless steel 304
Symbol
Note) The connection method is flange connection, as indicated below.FGC1: JIS 10KFF flange connectionFGC2: JPI300LbRF flange connectionFGC4: JPI600LbRF flange connection
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
Material
BronzeStainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 316/EpoxyStainless steel 316
Symbol
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements.
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material Note 1)
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm)
0.5 1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtration accuracy (µm) Note)
Note) For a comparison with the nominal filtra-tion accuracy according to the element category, refer to pages 774 and 775.
The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel.To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.When ordering only a vessel (replacement part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal material” from the above “How to Order”. Please use industrial filters in combination with parts made by SMC (ves-sels, elements etc.)
• Various types of elements can be selected according to the “filtration conditions,” and the unit can be used for a wide range of applications.
• This type has a vertical structure, so there is little loss of “filtrate.”
• Maintenance — element replacement in particular is easy.
Note 1)
Note 2)
Note 3)
Note 4)
771
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BronzeStainless steel 316
Cotton (Phenol)
CottonPolypropylene
Glass fiber
Stainless steel 304Stainless steel 316
Material
1, 2, 5, 10, 20, 4070, 100, 120
5, 10, 20
0.5, 1, 5, 10, 2050, 75, 100
5, 10, 20, 4074, 105
Nominal filtration accuracy (µm)
ø65 x l 250ø65 x l 500
ø65 x l 250ø65 x l 500
ø65 x l 250
ø65 x l 250
Size
Sintered metal
Paper
Fiber (Honeycomb)
Micromesh
Description
Applicable Element Specifications
1, 5, 10, 20
Specifications
Standard SpecificationsModel FGC
1, 2, 4
80
Flange (JIS 10KFF/JPI300LbRF, 600LbRF) 15 (1/2B), 20 (3/4B), 25 (1B) Note)
SGP/Stainless steel 304
Non-asbestos
Max. operating pressure (MPa)
Max. operating temperature (°C)
Port size
Vessel material (wetted parts)
Gasket
Note) In the case of JIS 10K, JIS B 2220 (Steel Welding Pipe Flanges) is used for this flange. JPI-7S-15-81 (Forged Steel Flanges for the Petroleum Industry) is used in the case of JPI.
Series FGC
Construction
Element mounting figure
OUTLET
AIR VENT
INLET
DRAIN
772Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INLET OUTLET25
DRAIN AIR VENT
ORIENTATION
Dimensions
Industrial Filter: Vessel Series Series FGC
INLET
AIR VENT
OUTLET
øA
3B (ø90)
250DRAIN
Rc3/8
Rc3/8
NN
BCA
ppro
x. D
Standard Models
Model
FGC4
FGC1
FGC2
Maximumoperatingpressure
1 MPa
2 MPa
4 MPa
Elementlength (l )
250
500
250
500
250
500
N (Port size)
15 (1/2B)
20 (3/4B)
25 (1B)
15 (1/2B)
20 (3/4B)
25 (1B)
15 (1/2B)
20 (3/4B)
25 (1B)
15 (1/2B)
20 (3/4B)
25 (1B)
15 (1/2B)
20 (3/4B)
25 (1B)
15 (1/2B)
20 (3/4B)
25 (1B)
øA
185
185
185
185
185
185
210
210
210
210
210
210
210
210
210
210
210
210
B
380
380
385
645
645
650
380
380
385
645
645
650
375
375
380
640
640
645
C
447
450
467
712
715
732
458
474
477
723
734
742
465
476
485
730
741
750
D
467
470
487
732
735
752
479
490
499
744
755
764
488
499
507
753
764
772
Flangestandard Note)
JIS 10KFF
JIS 10KFF
JPI 300LbRF
JPI 300LbRF
JPI 600LbRF
JPI 600LbRF
Mass(kg)
15
15
15
19
19
19
23
23
23
27
27
27
26
26
26
30
30
30
Internal volume(l )
2
3
2
3
2
3
(mm)
Note) In the case of JIS 10K, JIS B 2220 (Steel Welding Pipe Flanges) is used for this flange. JPI-7S-15-81 (Forged Steel Flanges for the Petroleum Industry) is used in the case of JPI.
773
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
• Outstanding mechanical strength, heat resistance and chemical resis-tance.
• Formed by sintering finely pow-dered metal, so a high filtration ac-curacy can be obtained.
• Even if clogging progresses, the element can be reused by cleaning.
• Main applicationsIdeal as a check filter for keeping fluid clean. All types of gases, fluids, general solvents and high-temperature fluids
Material Bronze
–180 to 200
Cannot be used.
Can be used depending on conditions.
B
1, 2, 5, 10, 20, 40, 70, 100, 120
0.7 MPa
0.1 MPa
Stainless steel 316
–180 to 300
Can be used. Note 1)
Can be used.
S
Acid
Alkali
Specifications
Note 1) Cannot be used with hydrochloric acid, hydrofluoric acid or phosphoric acid.Note 2) Varies depending on the seal material used. Note 3) Refer to “Element category” of “How to Order Industrial Filters” for each series.
How to Order Standard Elements for SMC Filters
RoHS∗ Not applicable for EB (bronze).
Please consult with SMC.
RoHS
Sintered Metal Filter Elements
• Four types of materials with different characteristics are available so the fil-ters are applicable to any application.
• Elements are economical because par-ticle capturing capacity is excellent, and element life is long.
• Elements are disposable so mainte-nance and replacement are easy.
• Main applications
Fiber Elements (Honeycomb) Specifications
How to Order Standard Elements for SMC Filters
Material Core material
Stainless steel 304
Polypropylene
Stainless steel 316
Operatingtemperature
(°C)
–20 to 100
0 to 60
0 to 400
Nominal filtrationaccuracy
(µm)
0.5, 1, 5, 10, 20, 50, 75, 100
0.5, 1, 5, 10, 20, 50, 75, 100
1, 5, 10, 20
Differentialpressure
resistance(Max.)
0.2 MPa
Elementreplacementdifferentialpressure
0.1 MPa
Cotton
Polypropylene
Glass fiber
Note) Size for all is ø65 x l 250.
Element material
Core material
Element category ofHow to Order Note)
Cotton
Stainless steel 304
EH10G
EH39R10GV
EH23R10GV
EH19R10GV
EH15R10G
EH11R10G
EH10R10G
EH8R10G
H
Polypropylene
Polypropylene
EHM10A
EHM39R10AY
EHM23R10AY
EHM19R10AY
EHM15R10A
EHM11R10A
EHM10R10A
EHM8R10A
T
Glass fiber
Stainless steel 316
—
EHK27R10S
EHK19R10S
EHK15R10S
EHK10R10S
—
—
—
G
0.5
1
5
10
20
50
75
100
Note) Refer to “Element category” of “How to Order Industrial Filters” for each series.
Glass fiber
Polypropylene
Cotton Cleaning water, General neutral fluids, General solvents, Dry air
Plating fluids, General acids, Alkali fluids,Industrial water, Cooling waterAcid fluids, High-temperature fluids
Operating temperature (C°) Note 2)
Nominal filtration accuracy (µm)
Max. differential pressure resistance
Element replacement differential pressure
Chemical resistance
Element category of How to Order Note 3)
A Note)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
SymbolElement seal material
Note) Not possible with bronze elements.
B 200EElement symbol
N005
BS
Element materialBronze
Stainless steel 316
Symbol
Element material
001002005010020040070100120
Nominal filtration accuracy (µm)Symbol
Nominal filtration accuracy (µm)100200300400
Element sizeø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
Symbol
Element size
125
10204070
100120
Standard ElementsSintered Metal / Fiber (Honeycomb)
Nom
inal
filtr
atio
n ac
cura
cy(µ
m)
774
RoHS-FG.qxd 10.7.26 5:21 PM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Material
Operating temperature (C°) Note 2)
Nominal filtration accuracy (µm)
Max. differential pressure resistance
Adhesive used
Element replacement differential pressure
Element category of How to Order Note)
Filter paper (Cotton, Phenol resin impregnated paper)
0 to 80
5, 10, 20
0.6 MPa
Epoxy resin
0.1 MPa
P
Note) Refer to “Element category” of “How to Order Industrial Filters” for each series.
Model EM100
Stainless steel 304
Epoxy resin
–5 to 100
Cannot be used.
Can be used.
M
5, 10, 20, 40, 74, 105
0.7 MPa
0.1 MPa
EM500
Stainless steel 316
—
–180 to 300
Can be used. Note 1)
Can be used.
L
Acid
Alkali
Specifications
Note 1) Cannot be used with hydrochloric acid, hydrofluoric acid or phosphoric acid.Note 2) Varies depending on the seal material used. Note 3) Refer to “Element category” of “How to Order Industrial Filters” for each series.
Materials
Jointing material
Operating temperature (C°) Note 2)
Nominal filtration accuracy (µm)
Max. differential pressure resistance
Element replacement differential pressure
Chemical resistance
Element category of How to Order Note 3)
NV
Element seal materialNBRFKM
Symbol
Element seal material
200EPPaper element
N010
005010020
Nominal filtration accuracy (µm)51020
Symbol
Nominal filtration accuracy (µm)
Note) Not possible with EM100 (Stainless steel 304)
A Note)
T Note)
NV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Element seal material
500EMMicromesh element
symbol
A074
(Size ø65 x l 250)
005010020040074105
Nominal filtration accuracy (µm)510204074105
Symbol
Nominal filtration accuracy (µm)
100500
Element composition symbolStainless steel 304Stainless steel 316
Symbol
Element composition symbol
Standard ElementsPaper / Micromesh
Paper Elements
• Stainless steel metal mesh has high filtration accuracy.
• Outstanding heat and chemical re-sistance. Applicable to a wide range of applications.
• Pleated type has 3 times the filtra-tion area of a cylinder.
• Filters are economical because they can be cleaned and repeatedly used.
• Main applicationsPlease use 40 microns or less as a high-pre-cision filter, and 74 microns or higher as a high-grade strainer. All types of gases and fluids, high-temperature fluids.
Micromesh Elements
Specifications
How to Order Standard Elements for SMC Filters
100200300400
Element sizeø65 x l 250ø65 x l 500ø65 x l 750
ø65 x l 1000
Symbol
Element size
How to Order Standard Elements for SMC Filters
• Cartridges are pleated for a large filtration area, and elements are economical due to their long ser-vice life.
• Main applicationsIdeal for filtration of hydraulic oil, lubricating oil, fuel oil, oils for the liquid gas industry, dry inert gases, and dry air.
775
RoHS
RoHS
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
RoHS-FG.qxd 10.7.26 5:21 PM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series FGDMade to OrderConsult with SMC for details.
With differential pressure indicator (X77)With differential pressure indication switch (X78)
Differential Pressure Indication
Precautions1. The figures in the above table indicate stationary
current. 2. An inductive load has a power factor (AC) of
0.75 or more, and a time constant (DC) of 7 msec or less.
3. A light load has an inrush current 10 times great-er.
4. Lead wires are connected using a screw tighten-ing terminal.
5. The electrical entry is equipped with a conduit (G1/2) and grommet.
6. Please wire freely to the microswitch indication symbol 1(COM.), 2(N.C.) and 3(N.O.).
7. If a holding mechanism is necessary for the non-reset type, provide it using electric circuits.
Microswitch Ratings
Ratedvoltage
(V) Normallyclosed
Normallyopen
Resistanceload
5 5 5 5 5 0.40.3
Noninductive load (A) Inductive load (A)
AC125AC250DC8DC14DC30DC125DC250
Normallyclosed
Normallyopen
Lightload
1.51
0.70.5
Normallyclosed
Normallyopen
Inductiveload
4 4
4 4 0.40.3
5 4
Normallyclosed
Normallyopen
Motorload
2.51.5
1.30.8
3 3 3 0.1 0.05
3 3 3 0.1 0.05
Inspectionwindow
COM.
N.O.N.C.
G1/2
Reset button
Inspection window
� Differential pressure indicator� Operation pressure—0.1 MPa� Once a value is displayed, it will continue to
be displayed until reset, even if the pump is stopped. (2-stage display reset type)
� Perform element replacement when the red ring floats up and covers the entire inspection window.
� Differential pressure indication switch� Operating pressure—0.1 MPa� When a value has been displayed, it will be
automatically reset when the pump is stopped. (Non-reset type)
� This is a visual dual-purpose 2-stage display. Perform element replacement when the switch has actuated (when the red ring floats up and covers the entire inspection window).
� N.C. and N.O. common
• There are two parts: the differential pressure indicator (X77) and differential pressure indication switch (X78).These can be mounted to all models of the FGD Series.
How to Order
AB
Element lengthl250
l500 (l250 x 2)
Symbol
Element length
Element category
BSTGHPML
Element type
Sintered metal
Fiber (Honeycomb)
Paper
Micromesh
Material
BronzeStainless steelPolypropylene
Glass fiberCottonCotton
Stainless steel 304/EpoxyStainless steel 316
Symbol
B
AccessoryNone
Bracket
Symbol
Nil
Accessory
X77X78
DescriptionNone
With differential pressure indicatorWith differential pressure idication switch
Symbol
Nil
Made to Order
Note 1) Not used with fiber elements.Note 2) Not possible with bronze elements
A Note 2)
TNV
Element seal materialNon-asbestos
FluororesinNBRFKM
Symbol
Note 1) The industrial filter/vessel series descri-bed in this catalog are products in which an element is incorporated into a vessel.
Note 2) To order only an element (replacement part), refer to “How to Order” on pages 774 and 775.
Note 3) When ordering only a vessel (replace-ment part), delete each symbol for “Element category”, “Nominal filtration accuracy (µm)” and “Element seal ma-terial” from the above “How to Order.”
Note 4) Please use industrial filters in combina-tion with parts made by SMC (vessels, elements etc.)
FGD C A 03 BB N002
030406
Port size Rc3/81/23/4
Symbol
Port size
X50001002005010020040050070074075100105120
Nominal filtration accuracy (µm) 0.5
1 2 5
10 20 40 50 70 74 75
100 105 120
Symbol
Nominal filtrationaccuracy (µm) Note)
Element seal material Note 1)
FGDC, EFGDT, F
Part no.
Differential pressure indicator Differential pressure indication switch
CB-62H CB-63H
CB-60H CB-61H
Applicable model
Differential Pressure Indicator/Switch Part No.
CETF
Cover
AluminumAluminum
SCS14SCS14
Case
SPCDSPCD
Stainless steel 316Stainless steel 316
Gasket/O-ring
NBRNBR
FluororesinFluororesin
Seal
NylonNylon/Fluororesin
FluororesinFluororesin (Antistatic specifications)
SymbolMaterial
Note) For a comparison with the nominal filtration accuracy according to the element category, refer to pages 774 and 775.
Made toOrder
776
7-04-03-FGA-B-C.qxd 09.10.2 11:03 AM Page 11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
Aluminum, SPCD
Aluminum
0.7
NBR, Nylon
1.3
1.5
1.7
2.2
2.4
3.4
80
0.1
Rc3/8, 1/2, 3/4
Max. operating pressure (MPa)
Max. operating temperature (°C)
Differential pressure indicator operating pressureDifferential pressure indication switch operating pressure
(MPa)
Port size
Material
Mass (kg)
Internal volume (l )
Body
Differential pressure indicatorDifferential pressure indication switch
X77X78
Seal
FGDCA/FGDEA FGDCB/FGDEB
SCS14, Stainless steel 316
Stainless steel 303
1.0
PTFE
2.3
2.5
1.7
3.8
4.0
3.4
FGDTA/FGDFA FGDTB/FGDFB
Dimensions
With differential pressure indicator (X77) With differential pressure indication switch (X78)
Model
FGDCFGDE
FGDTFGDF
Element length
A (l 250)
B (l 500)
A (l 250)
B (l 500)
3/8, 1/2, 3/4
A314
574
315
574
B D70
70
70
70
C374
634
375
636
(mm)
Model
FGDCFGDE
FGDTFGDF
Element length
A (l 250)
B (l 500)
A (l 250)
B (l 500)
3/8, 1/2, 3/4
A314
574
315
574
B D70
70
70
70
C407
665
408
665
(mm)
OUT
B
C
A
DRAING1/4
AIR VENTM6 x P1
IN
84
(119)
32
108
2 x RcD
OUTIN
DRAING1/4
AIR VENTM6 x P1
C
BA
60
84(119)
32
108
G1/2
2 x RcD
Specifications
Industrial Filter: Vessel Series Series FGD
777
FGD
FGE
FGG
FGA
FGB
FGC
FGF
FGH
EJ
ED
FQ1
FNEB�ES�
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com