Smart Metering Development

63
Smart Metering Development Tczew, XI 2012 r. 1

description

Tczew, XI 2012 r. Smart Metering Development. Smart Metering Development. Continued cooperation with Flonidan A/S in development of GxS line meters UniSmart : Telemetry Module Automatic Meter Reading Walk-by and Drive-by systems Stationary systems - PowerPoint PPT Presentation

Transcript of Smart Metering Development

Page 1: Smart  Metering  Development

Smart Metering Development

Tczew, XI 2012 r.

1

Page 2: Smart  Metering  Development

a. Continued cooperation with Flonidan A/S in development of GxS line meters

b. UniSmart: Telemetry Module

c. Automatic Meter Readinga. Walk-by and Drive-by systemsb. Stationary systems

d. Smart Components Developmenta) Shut-Off ball Valve with stepper motorb) New Cable Transferc) Modular design of New Metrix EU

e. New Fields for Cooperation a) Secure Meters Ltd.b) GWi

f. Metrix employee are members of:a) OMS workgroupb) prEN16314 Additional Functionalities WG

Smart Metering Development

Page 3: Smart  Metering  Development

New Smart Meters GxS series combine all the best features and capabilities of previous models :

•Reliable, resistant to interference, optical pulse readings from measuring unit, using a Gray code wheel

•Much better metrological accuracy due to error curve correction

•Temperature compensation•Internal shutt-off valve •Volume and Alarms registarion•Remote safe reading using AES-128

encryption•Wired/Wireless communication EN-13757

GxS Smart Gas Meters

NTA8130 + DSMR v.2.2/2.3/3.0 3

Page 4: Smart  Metering  Development

Compact design

•MID Class 1,5•ATEX II 1/2 G Ex ia/ib IIB T3•IP-54 •Over 15 battery life time

4

Page 5: Smart  Metering  Development

Electronic Unit has the ability to compensate for the effect of temperature on the measurement error.

Temperature correction is performed in a volume of 4 points: -25, 0, +30, +55 C. Between these points, linear interpolation is used

Temperature compensation

-20 -10 0 10 20 30 40

-10%

-5%

0%

5%

10%

15%

temperature

Erro

r

Temperature sensors

5

Page 6: Smart  Metering  Development

6

Page 7: Smart  Metering  Development

Curve error correction

Much better measurment accuracy• errors below limit ± 0,3% !!!

Page 8: Smart  Metering  Development

From magnetic coupling…

… to optical Gray code reading

Evolution instead of Revolution

Page 9: Smart  Metering  Development

• Realiable pulse reading method use 3 optical sensors, allowing to measure with ressolution of 1/8 rotation of measuring unit cyclic volume.

• Optical pulse reading is tamper proof against magnetic fields

Gray code wheel…

phototransistors

Page 10: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

10

Page 11: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

11

Page 12: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

12

Page 13: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

13

Page 14: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

14

Page 15: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

15

Page 16: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

16

Page 17: Smart  Metering  Development

1 2 3

1 2 3

Gray code wheel …

17

Page 18: Smart  Metering  Development

18

New Cable Transfer

• The seals are capable of remaining hermetic after exposure to 820°C • The leakage rate of the seal after exposure to 820°C would be better

than 1x10-6 cc per sec of helium.

Page 19: Smart  Metering  Development

GSU shutt-off valve

Safe, internal, build-in new generation of ball valve:

• Safe open function• Low pressure drop in comparison to competitive

designs• Two state valve position control (fully closed / fully

open), confirmed by realiable microswitch designed

to work in gas and oil enviroment• Installation on the gas meter outlet

(less contamination)• Higher Intrinsically Safty - using

industriy field proven stepper motor

manufactured by Johnson Electric Group ® 19

Page 20: Smart  Metering  Development

Pressure dropup to

hm316 (Qmax@G10)

20

Page 21: Smart  Metering  Development

Two state position control

Microswitch

Page 22: Smart  Metering  Development

Modular design:UG-NL 220 mm adapter

22

Page 23: Smart  Metering  Development

Modular design:UG-EN 6” (152,4 mm)

23

Page 24: Smart  Metering  Development

Modular design:UG-F 130 mm

24

Page 25: Smart  Metering  Development

Flexibility

Comaptible with all UG meters• 1,2 dm3• 2,2 dm3

Page 26: Smart  Metering  Development

Design challenges

Design optimalization using CFDComputional Fluid Dynamics

26

Page 27: Smart  Metering  Development

Pressure dropacc. CFD ~0,2 mbar

CFD simulations

Real pressure drop ~0,15 mbar

Other models<0,05 mbar 27

Page 28: Smart  Metering  Development

CFD optimized adapter of:UG-F 110 mm

28

Page 29: Smart  Metering  Development

UG-NL 220 mm

Page 30: Smart  Metering  Development

UG-NL 220 mm

Page 31: Smart  Metering  Development

UG-NL 220 mm

Page 32: Smart  Metering  Development

UG-NL 220 mm

Page 33: Smart  Metering  Development

UG-F 130 mm

Page 34: Smart  Metering  Development

UG-F 130 mm

Page 35: Smart  Metering  Development

UG-F 130 mm

Page 36: Smart  Metering  Development

UG-F 130 mm

Page 37: Smart  Metering  Development

UniSmart: telemetry module1. Communication

2. Pulse counting a. 1 pulse = 1 full rotation of last counter roller

(for meters G1,6 - G6 1 puls=10dm3, for meters G10 1 ipuls=100dm3)

b. Algorithm of errors elimination such as errors due to mechanical vibration of rollers in counter.

37

Page 38: Smart  Metering  Development

4. The conversion of the volume pulse(m3);5. Flows history (60-dayly, 120-monthly);6. Alarm registers:

a. Interference by an external magnetic field;b. Exceeding the maximum flow(Qmax);c. Lack of pulse.

7. Bootloader (possibility of remote firmware upgrade) under developmentDatagram Encryption AES-128 acc EN13757-3:

a. OMS (with dynamic initialization vector);b. NTA (with dynamic initialization vector); possible developmentc. NTA (with static initialization vector). possible development

8. Power supply: 1x lithium battery type AA;9. Battery Operation 10 years

UniSmart: Functionality

Page 39: Smart  Metering  Development

AMR (ang. automatic meter reading)

Remote reading system Walk-by system

Stationary system

39

Page 40: Smart  Metering  Development

Walk-by system40

Page 41: Smart  Metering  Development

Inkasent PDA application

41

Page 42: Smart  Metering  Development

PSION Terminal

Mobile terminal PSION WORKABOUT PRO

42

Page 43: Smart  Metering  Development

Stationary system

43

Page 44: Smart  Metering  Development

• File generating *.csv• GSM hubs can supply with

solar panels

Data Concentrator (MUC) under development

Page 45: Smart  Metering  Development

GSM Hubs:• Power supply 230 V AC• Solar panels power supplies

Data Concentrator (MUC) under development

Page 46: Smart  Metering  Development

M-BUS retransmitterunder development

Retransmitters• Power supply 230 V AC• Baterry supply

Page 47: Smart  Metering  Development

47

Pilot Instalation in:Wielkopolskiej Spółka Gazownictwa S.A.

Page 48: Smart  Metering  Development

Pilot Instalation in WSG S.A.

GxS Smart Meters has been used in the pilot with OMS protocol communication.

Meters configuration includes:Error curve correction (Vc)Base Volume conversion (Vb)

48

Page 49: Smart  Metering  Development

Additional Functionalities Implemented during pilot instalation

a) Solution from Smart Gas Meter side which allows Customer to balancing the gas network system.

b) Interopability: Overall system has been integreated to fit both for existing aplication systems and at device level too.

c) We have been greatfull to receive interest from National Notified Body of Oil and Gas (INiG). Cooperation with INiG can enhance an ongoing Project

49

Page 50: Smart  Metering  Development

1. More then 2000 GxS Smart Gas Meters

2. Drive-by reading by PSION WORKABOUT PRO 3 and car roof antenas

50

Page 51: Smart  Metering  Development

Walk-by / Drive-by

PSION WORKABOUT PRO

51

Page 52: Smart  Metering  Development

52Drive-by AMR reading

Page 53: Smart  Metering  Development

53External car roof antena 868 Mhz

Page 54: Smart  Metering  Development

54Terminal PSION WORKABOUT PRO 3

Page 55: Smart  Metering  Development

55

Screenshoots from mobile app

Page 56: Smart  Metering  Development

56

Screenshoots from mobile app

Page 57: Smart  Metering  Development

57

Aplikacja Inkasent Mobile

Screenshoots from mobile app

Page 58: Smart  Metering  Development
Page 59: Smart  Metering  Development

Customer Customization

Page 60: Smart  Metering  Development

Prepayment ZigBee Smart Gas Meter Project

Page 61: Smart  Metering  Development
Page 62: Smart  Metering  Development

Project database

Page 63: Smart  Metering  Development

Thank you for your attention

63