Smart Home Alarm System

12
Smart Home Alarm System User Manual When designing, this system be added many amazing & practical new features, to make sure a better smart life.

Transcript of Smart Home Alarm System

                               

 

 

 

                                Smart  Home  Alarm  System                                                         User     Manual        

       When   designing,   this   system  be   added  many   amazing  &   practical   new  features,  to  make  sure  a  better  smart  life.      

      Main  Features  :      

■ 99  defense  zones  and  6  zone  types  of  each    ■ Stress  alarm  &  tamper  alarm  &  anti-­‐false  alarm  &    

anti-­‐jamming    ■  Built-­‐in  Temperature  scope  alarm  &  Knock-­‐over  alarm  ■  Door-­‐open  alert  (  two-­‐way  door  contact           for  optional  )  ■  60  arm/disarm/alarm  records  obtained  ■  LCD  program  menu  /  Touch  keypad  &  Voice  prompt  ■  5  international  languages  available  (  extended  up  to  7             languages  )  ■  Pairing  status  obtained  &Sensors  real-­‐time  power  volume                 obtained  ■  SMS  alert  for  any  16  zones  /  10  remotes  be  renamed  ■  12  seconds  voice  message  for  alert  &  12  seconds  voice             Memo  ■  Low-­‐voltage  alert  for  panel  &  accessories  ■  6  phone  numbers  for  alarm  calls/SMS  alert  ■  Breathing  LED  light  for  Out  arm/Home  arm  status  ■  All  settings  via  Keypad/SMS/Phone  call  ■  6  timers  for  arm/disarm    ■  SMS  alert  for  extra  power  on/off  ■  Direct  phone  call  as  normal  phone  ■ Etc…  

   

         

   Panel  Diagram    

   

 

   Quick  Installation      1. Insert  a  SIM  card  into  the  panel  ;  make  sure  the  SIM  card  is  valid,and  

PIN  code  be  deactivated  when  have  ;    

2. Switch  on  the  panel,  the  icon  of  SIM  card  will  flash  a  while  to  search  gsm   network.   when   the   icon   doesn’t   flash   ,then   gsm   network   be  searched  out  ;  

 3. Input  Program  password  (  123123)  +Menu  button  ,Menu  display  will  

be  entered  ,flip  6  to  “Pairing”  to  pair  the  remotes  and  sensors  ;    When  pairing  sensor  ,you  can  choose  Zone  No.  and  Zone  type  before  start  pairing  ;also  you  can  change  the  Zone  type  after  pairing  ;    P.S.  If  you  could  not  make  sure  if  a  remotes  or  sensor  has  be  paired  or  not  ,you  can  inquiry  the  pairing  ,then  the  LCD  display  will  show  the  remotes   or   sensor   be   paired   or   not   ,and   meantime   shows   its  real-­‐time  power  volume  ;    

4. Flip  6  to  “  Phone  Number  ”,and  input  the  alarm  numbers  to  receive  phone  call  or  SMS  alert   ;then  flip  8  to  finish  the  SMS  setting(Alarms  SMS;   Arm/Disarm   SMS;   System   SMS   )   and   Phone   call   setting  (  Activate  /Closed  );    

5. Flip   6   to   “Voice   message”   to   record   the   voice   message   ,so   people  whom  receives  phone  call  will  know  what  happens  when  emergency;  

 6. For  more  settings,  kindly  pls  follow  its  display  menu  to  program  .  

   

 

   Functions  Explanation    1. Stress  alarm    

When  you  be  threatened  to  disarm  the  system  by   intruder,  you  can  input   (   operation  password  plus   1   )+Disarm  button   ,the   system  will  stealthily  make  alarm  call  and  send  SMS  alert  to  other  people  .    

2. Knock-­‐over  alarm  When   emergency   ,you   can   knock   over   the   panel   to   activate   the  alarming  .    

3. Temperature  scope  alarm  You   can   program   the   temperature   scope,   so   when   temperature  oversteps  the  scope,  the  panel  will  activate  alarming  .    

4. Anti-­‐false  alarm    Pair   two   sensors   into   one   zone   and   activate   the   “False-­‐alarm”   in  “Sensor  pairing”,and  activate  “False-­‐alarm”  in  “Switchs  setting”.  then  only   when   two   sensors   be   triggered   successively   over   6   seconds,  alarming   will   be   activated.   This   way   can   avoid   false   alarms   which  caused  by  sunshine  exposure/wind  blow/pet  moving,etc…    

5. Tamper  alarm  When   panel   be   illegally   disassembled,   Panel   will   automatically  activate  the  alarming  ,and  make  alarm  call  and  send  SMS  alert.    

6. Door-­‐open  Alert  (  two-­‐way  door  contact  supported  )  Activate   this   function   in   “Switchs   setting”.  When   door   be   forgot   to  close  ,you  will  fail  to  arm  the  system  ,meanwhile  the  LCD  display  will  show  “door  open”  to  remind  you  to  close  the  door  .    

   

7. Voice  Memo  (12  seconds)  In  disarm  status,  long  press  9  via  panel,it  will  start  to  record  the  voice  memo  ;long  press  7  via  panel  to  play  the  voice  memo  .    

8. White  list  When  this  function  be  activated  ,all  the  phone  numbers  you  input  are  in  white  list  by  default  .so  you  and  other  people  don’t  need  to  input  Operation  password  (  1234  )  to  receive  alarm  calls.  

 9. Arm/Disarm  Timers  

Our  system  supports  6  timers  for  Arm/disarm  .    

10. Rename  the  SMS  alert  for  10  remotes  /  16  zones  You  can  rename  those  SMS  alert  by  SMS  commands:  123123#ZMSG=Zone  No.,SMS  alert  123123#RC1MSG=Remotes  No.,SMS  alert  123123#RC3MSG=Remotes  No.,SMS  alert  For  example:  1) rename  the  SMS  alert  of  16th  zone  to  be  “  an  intruder  breaks  into  

my   front   door”:123123#ZMSG=16,an   intruder   breaks   into   my  front  door    

2) rename  the  SMS  alert  of  Out  arm  button  of  1st  remotes  to  be  “My  son   goes   to   school   now”:   123123#RC1MSG=01,My   son   goes   to  school  now  

3) rename  the  SMS  alert  of  Disarm  button  of  1st  remotes  to  be  “My  son   back   home   now”:   123123#RC3MSG=01,My   son   back   home  now    

11.Work  with  wireless  strobe  siren  (433Mhz)         When  strobe  siren  in  pairing  status,  press  1234+Disarm  via  panel             to  get  paired  with  strobe  siren  ,then  will  work  together.  

            Many  strobe  sirens  (  indoor  or  outdoor  )  can  be  added  with  the             panel  to  work  at  same  time  if  need  .  

 12.  Work  with  two-­‐way  keypad           When  keypad  in  pairing  status,  press  1234+Disarm  via  panel             to  get  paired  with  keypad  ,then  will  work  together.    

 

           

   System  Settings  By  SMS  Commands    Besides   programming   on   panel,   this   system   can   be   finished   settings  remotely  by  SMS  commands.  Just  text  messages  to  panel  as  below,  the  correspondent  setting  will  be  finished  exactly  .      Time  for  delay  arm  :       123123#02X#       (X=00-­‐90;  60  by  default)    Time  for  delay  alarm:     123123#04X#       (X=00-­‐90;  00  by  default)    Time  for  delay  disarm:  123123#05X#       (X=00-­‐90;  00  by  default)    Siren  time:                     123123#06X#       (X=00-­‐30;  01  by  default)    Backlight  :                   123123#09X#       (X=000-­‐180;  030  by  default)    Built-­‐in  siren  volume:  123123#13X#        

(X=0-­‐3,0-­‐mute,1-­‐low,2-­‐middle,3-­‐high;  3  by  default  )    

Phone  number:           123123#41XY#       (X=  1-­‐6,Y=phone  number)    System  time:               123123#50YYMMDDHHMM#      

(YY=Year;MM=Month;DD=Day;HH=Hour;MM=Minute)    

Timer  for  Arm/Disarm:  123123#56XYZHHMM#                     (X=1-­‐6;Y=0-­‐1,0-­‐closed,1-­‐activate;Z=1-­‐3,1-­‐Out  arm,2-­‐Home                             arm,3-­‐Disarm;  )    Program  password:         123123#60X#                           (X=password,  less  than  6  digit;  123123  by  default)  

   Operation  password:       123123#61X#                         (X=password,  less  than  4  digit;  1234  by  default)    Zone  type:                         123123#64XYZM#  (X=01-­‐99;Y=1-­‐6,1-­‐closed,2-­‐immediate,3-­‐urgent,4-­‐home,5-­‐doorbell,6-­‐delay;Z=0-­‐1,0-­‐voice  prompt  closed,1-­‐voice  prompt  activated;  M=0-­‐1,0-­‐false  alarm  closed,1-­‐false  alarm  activated;)    Temperature  scope:         123123#78XYZ#           (X=0-­‐1,0-­‐closed,1-­‐activate;Y=lower  limiting  value;  Z=upper      

limit  value)    

System  status  setting:       123123#80X#        (X=1-­‐4,1-­‐Out  arm,2-­‐Home  arm,3-­‐Disarm,4-­‐SOS  alarming  )    

Rename  SMS  alert  for  16  zones  :         123123#ZMSG=X,Y                                                               (X=01-­‐99;Y=SMS  alert)    

Rename  SMS  alert  for  10  remotes:     123123#RC1MSG=X,Y                                                                 123123#RC3MSG=X,Y                                                                   (X=01-­‐10,Y=SMS  alert)                      

   Standard  Package               Control  Panel     x1                       PIR  Detector     x1            

             

        Remote  Controls     x2                     Door  Contact     x2    

               

               

   More  Options      Two-­‐Way  Keypad  (  RFID  Tags  /  LCD  Display  )      

       Mini  Strobe  Siren  (  Red  /  Blue  Lens  )  

 

 Window  Contact      

 

   Technical  Specifications:    Power  input:  DC  5V  2000mA,10Wh  GSM  frequency:  850/900/1800/1900Mhz  Backup  battery:  3.7V  1100mAh  rechargeable  Li-­‐battery  Built-­‐in  siren:  80dB  Standby  current:  ≤60mA  Alarm  current:  ≤300mA  Radio  frequency:  433.92MHz  Extensible  accessories:  10  remote  controls,89  wireless  detector/sensor  History  records  :  60  Housing  material:    ABS  plastic  Operation  condition:  Temperature  :  -­‐10℃~+55℃  Relative  humidity:   ≤80%  (non-­‐condensing  )  Dimension  (L  x  W  x  H):  140  x  140  x  20  mm