Smart Biomedical Monitoring System
-
Upload
cardiacinfo -
Category
Documents
-
view
1.410 -
download
1
Transcript of Smart Biomedical Monitoring System
![Page 1: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/1.jpg)
1
Biomedical Monitoring System
Biomedical Embedded Systems Technology
Presentation for ENSC 440/305 Instructors: Dr. Andrew Rawicz, Steve
Whitmore Department of Engineering Science
Simon Fraser University
![Page 2: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/2.jpg)
2
Team Members Motivation System Overview Hardware Software Budget Business Plan Scheduling Problems Encountered Future Extensions Questions
Outline
![Page 3: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/3.jpg)
3
Team Members
Alireza Rahbar (CEO)
Farzad Abasi (CTO)
Sam Sayfollahi (VP of Marketing)
Parna Niksirat (VP of Operation)
Shaghayegh Hosseinpour (VP of R&D)
![Page 4: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/4.jpg)
4
Motivation
28.5 % of all death in U.S. are caused by cardiovascular diseases in 2002World Health Organization
In 2006, heart disease was the leading cause of death in U.S.American Heart Association
Every minute CVD cause one death in U.S. American Heart Association
![Page 5: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/5.jpg)
5
Analyzing the heartbeat
Measure, amplify and record the natural electrical potential created by the heart
ECG Signal Bandwidth: o.5Hz ~ 100 Hz
ECG Signal Amplitude:~1mV
Electrocardiogram (ECG)
![Page 6: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/6.jpg)
6
Electrocardiogram (ECG)
![Page 7: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/7.jpg)
7
Our Design
Non-invasive and mobile
Monitoring result is transferable to medical professionals
Affordable
![Page 8: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/8.jpg)
8
System Overview
![Page 9: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/9.jpg)
9
Hardware Overview
![Page 10: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/10.jpg)
10
Hardware- ECG Circuit
![Page 11: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/11.jpg)
11
ECG Circuit-Block Diagram
PROTECTIONCIRCUIT
DIFFERENTIAL AMPLIFIER
(AD620)
NOISE FILTERING & AMPLIFICATION
OUTPUT
RIGHT LEGDRIVE
INPUTS(Right &
Left Hand Signals)
![Page 12: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/12.jpg)
12
Hardware- Microcontroller
8bit RISC AVR Processor (A T mega644)10MHz External crystal oscillator8 digit to analog (ADD) 10 bit resolution15 Digital Input/OutputUART interface64K Internal Program Flash2K Internal EEPROM4K Internal SRAM8 MB External Serial Flash: Suitable to
save acquired data from sensor
![Page 13: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/13.jpg)
13
Hardware- WirelessPower Output: 100 mW (20 dBm) Indoor/Urban range: Up to 1200 ft(370m)Outdoor/RF line-of-sight range: up to 15
miles (24 km)Receiver sensitivity: -106 dBmRF data rate: 9.6 KbpsSupply Voltage: 3-3.6 VDCFrequency Band: 910-918 MHz
![Page 14: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/14.jpg)
14
Software Overview
Graphical User Interface (GUI)
Wireless Module
Data Acquisition System
On-Board Flash Memory
![Page 15: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/15.jpg)
15
GUI
![Page 16: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/16.jpg)
16
Software Overview
Graphical User Interface (GUI)
Wireless Module
Data Acquisition System
On-Board Flash Memory
![Page 17: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/17.jpg)
17
Wireless
Acquire data from micro-controller
Send data to receiver Receive data
Communicate with GUI
![Page 18: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/18.jpg)
18
![Page 19: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/19.jpg)
19
Business Plan
Estimated Cost For Mass Production:
Subsystem Estimated
Micro-Controller $15
Wireless Module-Dash7 VIII (Biomedical) $5
PCB $3
Total Cost $23
![Page 20: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/20.jpg)
20
Proposed and ActualBudget
Subsystem Estimated Actual
Micro-controller $40 $107
Daughter board module for USB connection $40 $66
Connector module for micro-controller and related wires $10 Borrowed
Heart beat sensor (ECG) leads and wires $250 Borrowed
Wireless (transmitter and receiver) $100 $100
Shipping costs $40 $20
Parallel port to USB converter $20 $10
ECG circuit parts $50 $180
Total cost $550 $483
![Page 21: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/21.jpg)
21
Schedule
Blue Line : Actual TimeGray Line : Estimated Time
![Page 22: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/22.jpg)
22
Problems Encountered
• Micro-Controller Communication ProblemsSynchronization of data
• Wireless Communication problemOne UART port available
• Graphical User Interface (GUI)CPU UsageSlow-motion graphing
• ECG Circuit and NoiseNoise reductionDifferentiation
![Page 23: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/23.jpg)
23
Future Extensions
Making the device more user-friendly and practical by using:
Printed Circuit Board (PCB) instead of breadboard
Bluetooth transmission instead of Xbee module
Additional electrodes
More efficient wireless module (Dash7)
![Page 24: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/24.jpg)
24
Conclusion
• Portable ECG monitoring device• Wireless functionality• USB Connectivity• On-Board Flash Memory• Custom ECG circuit• Graphical User Interface (GUI)
• Importance of team work & collaboration
• Problem Solving
![Page 25: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/25.jpg)
25
Thanks to
Dr. Andrew RawiczSteve WhitmoreDr. Lucky OneEngineering Student Society Dr. MehdiMoradiDr. Ash ParameswaranSteve SwiftAli OstadfarSara MoghaddamjooArash Ahmadi
![Page 26: Smart Biomedical Monitoring System](https://reader038.fdocuments.net/reader038/viewer/2022103018/558a3288d8b42a26138b46b3/html5/thumbnails/26.jpg)
26
Questions