Slide 1Slide 1Comarra Limited - 2006 Slide 1
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Slide 1Comarra Limited - 2006 Slide 1
COMARRACOMARRATelecom Transmission Solutions
16 Port, E116 Port, E1Digital Access Cross Connect SwitchDigital Access Cross Connect Switch
VCL MegaConnect - Jr. E1 DACSVCL MegaConnect - Jr. E1 DACS
Updated : March 2006VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Slide 2Slide 2Comarra Limited - 2006 Slide 2
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
• 16 Ports, E1 Digital Access Cross Connect Switch.
• Offers full cross-connect functionality to cross-connect, and / or aggregate DS-0s, "n"x64Kbps consecutive data channels and, fractional E1 channels to full E1 channels.
• Uni-directional Monitoring.
• Bi-directional Monitoring .
• Non - Intrusive Monitoring Application / Combine traffic from partially - utilized facilities onto a single fully - utilized E1.
• Occupies only a 2U high rack-space.
• 19-inch stand-alone unit provides connectivity of up to 16 E1 ports.
• Units operates on a 48VDC input power-supply (AC input adapter is optional).
E1 Digital Access Cross Connect Switch
ProductProduct OverviewOverview
Slide 3Slide 3Comarra Limited - 2006 Slide 3
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
•ISP - Providing Fractional E1s to Subscribers.]
•Data - Aggregating Fractional E1 Data Circuits.
•Monitoring & Billing - Non-Intrusive Line Traffic Monitoring for “Listen-Only”
and Billing Applications.
•Cellular - Extending Fractional E1 ports from MTSO to Cell-Sites.
ApplicationsApplications
Slide 4Slide 4Comarra Limited - 2006 Slide 4
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
•Remote TCP / IP Access for configuration and Monitoring.
•Text based user friendly CLI for easy configuration.
•Telnet option.
•Available in 16 E1 ports configuration.
HighlightsHighlights
Slide 5Slide 5Comarra Limited - 2006 Slide 5
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
•Provides DS0, "n"x64Kbps and Fractional E1 grooming for up to 16 E1 ports.
•Rear Access.
•User friendly CLI (text based) commands.
•Telnet (10 / 100 BaseT) option.
•Easy to install.
•Configurable from 2, E1 ports to 16, E1 ports depending on user
requirements.
•LED Indications on the front panel for alarms and status.
FeaturesFeatures
Slide 6Slide 6Comarra Limited - 2006 Slide 6
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
•Reduce access costs by combining partially loaded E1s to a single E1.
•Rear access wiring. Improves wiring and cable management.
•Support Nx64kbps fractional E1 operation and grooming.
•Can be ordered for (non - Intrusive) connecting to monitoring / billing
equipment for Live - Traffic monitoring and cross connect functions.
•Easy to install and simple to use.
BenefitsBenefits
Slide 7Slide 7Comarra Limited - 2006 Slide 7
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
ApplicationsApplications
Slide 8Slide 8Comarra Limited - 2006 Slide 8
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
ApplicationsApplications
Slide 9Slide 9Comarra Limited - 2006 Slide 9
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
To monitor an E1 link in a single direction, you will need to connect ONE high impedence E1, RX pair of the DACS, as it is only the Rx (RECEIVE) pair that is capable of listening. Please leave the Tx (TRANSMIT) pair un-connected.
ApplicationsApplications
Slide 10Slide 10Comarra Limited - 2006 Slide 10
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
To monitor an E1 link in both directions, you will need to connect TWO high impedence E1, RX pairs of the DACS, i.e. use 1, Hi-Z E1 ports.
ApplicationsApplications
Slide 11Slide 11Comarra Limited - 2006 Slide 11
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
The VCL-DACS, E1- Digital Cross Connect Switch unit is a 2U, 19 Inch Shelf, fitted with a backplane that provides rear access of all external interfaces. The 2Mbps electrical I/O, power input, alarm extension and the NMS port are all accessed from the backplane. The 2Mbps, E1 Interfaces are, 120 Ohms twisted pair RJ-45 connectors.
VCL-DACS, E1 Digital Cross Connect Switch - Shelf DescriptionVCL-DACS, E1 Digital Cross Connect Switch - Shelf Description
Slide 12Slide 12Comarra Limited - 2006 Slide 12
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
E1 InterfaceLine Rate E1 (2.048 Mbps ± 50 bps)Available Time-Slots 1-31Framing G.704Electrical G.703Jitter G.823Impedance 120 OhmConnector RJ-45 (F)
Time-slot selection:ANY-TO-ANY through an internal, best byte, non-blocking TSI Switch.
Clock :Internal (Stratum3 level)Loop-TimedExternal 75 Ohms - 2.048 Mhz
- 1.544 Mhz
Technical SpecificationsTechnical Specifications
Slide 13Slide 13Comarra Limited - 2006 Slide 13
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Management and Control:• Serial Management Port (RS232) - COM Port.• 10 / 100 BaseT for Remote Management over a LAN.• 10 / 100 BaseT Telnet over a TCP-IP Network.
Command Language:• Command Line Interface (english text commands).• Windows based GUI (optional).
Specification and Regulation Compliance• Meets CE requirements.
• Complies with FCC, Part 68 and Part 15 subpart A specifications.
• Safety - UL 1459 Issue 2.
Technical SpecificationsTechnical Specifications
Slide 14Slide 14Comarra Limited - 2006 Slide 14
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Alarm Contact Closures1 Alarm Relay, Type - Form "C" relay,
TemperatureOperating 00C to 500CHumidity 5% to 95% Non-Condensing
Power ConsumptionPower Consumption 18 Watt
Mechanical SpecificationWidth : 480mmDepth : 280mmHeight : 90mmWeight : 4.20Kg.
Technical SpecificationsTechnical Specifications
Slide 15Slide 15Comarra Limited - 2006 Slide 15
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Alarm Status Monitoring
• Loss of incoming Signal at all 2Mbps ports• Configuration Error Alarm• In addition to the above monitoring facilities, VCL-DACS is provided with LED's, which indicate various fault conditions
Monitoring VCL-DACS via LED Indications
• 1 to 16 E1 Ports LED indicators• +3 VDC present• -48VDC present• Configuration Error
Technical SpecificationsTechnical Specifications
Slide 16Slide 16Comarra Limited - 2006 Slide 16
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Digital Access Cross Connects - E1 / T1 , E3, DS3, 10/100 BaseT Ethernet Groomers (Hi-Z Non-intrusive Hi-Impedance Monitoring) Echo Canceller & Voice Quality Enhancement Solutions - E1, T1, DS3 and STM-1 E1 Drop-Insert (Add-Drop) Voice and Data Multiplexers STM-1 Add Drop Multiplexer with Ethernet GSM Gateways - E1/T1 E1 PRI ISDN (Euro ISDN) Q.931 Multiplexers Channel Banks E2 (4 E1), 2/34 Mbps PDH Multiplexer, 34 Mbps OLTE VoIP SS7 and C7 Solutions Nextone Softwitch CISCO Gateways Quintum Tenor VOIP Gateways Networking & Engineering Solutions. Hosted Solutions.
Comarra’s ProductsComarra’s Products
Slide 17Slide 17Comarra Limited - 2006 Slide 17
VCL - MegaConnect - Jr., E1 DACSVCL - MegaConnect - Jr., E1 DACS
Thank you for your attentionThank you for your attention
For more details visit us at our Website at
http://www.comarra.co.uk
123 Springvale Road, Winchester HantsSO23 7LE UK
Phone: +44 (0) 20 7871 9524E-mail: [email protected]