©SJA 2007
Søren Juhl Andreasen and Søren Knudsen Kær
Aalborg UniversityInstitute of Energy Technology
Dynamic Model of High Temperature PEM Fuel Cell Stack Temperature
![Page 2: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/2.jpg)
2
©SJA 2007
Presentation outline
∙ HTPEM features∙ Experimental fuel cell system setup∙ Previous work
▫ Stack temperature profile identification
∙ Governing equations▫ Energy balance▫ Fuel cell power input▫ Convection▫ Conduction
∙ Model definitions∙ Model assumptions∙ HTPEM FC stack temperature control
▫ Current feedforward▫ PI controller
∙ Model validation▫ Heating▫ Operation▫ Pulsating air flow
![Page 3: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/3.jpg)
3
©SJA 2007
HTPEM PBI(H3PO4)-membrane features
Operating conditions▫ FC operating conditions 120-200oC, preferred range (160-180oC)▫ Allowable CO content 1-3% (10000-30000 ppm)▫ No humidification of anode- and cathode flows▫ Fast response to load changes due to high temperatures (even with CO)
Advantages▫ No humidification of cathode or anode => Very simple FC system and stack design▫ No liquid water should be present in FC membranes => Simple stack design▫ Large CO-tolerance (1-3%), LTPEM is typically 10-100ppm▫ Possible system integration with simple reformer, due to high CO tolerance▫ Storing hydrogen as a liquid hydrocarbon => methanol, ethanol etc.▫ Avoiding and extra cooling circuit, by using extra cathode air
Disadvantages (Challenges)▫ Lower cell voltage = Lower efficiency (not as low as DMFC though)▫ Start-up time is often long because of high operating temperatures (min 100oC) to avoid water condensation.▫ High demands for materials at these elevated temperatures
![Page 4: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/4.jpg)
4
©SJA 2007
Performance of HTPEM fuel cell
©SJA 2007
![Page 5: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/5.jpg)
5
©SJA 2007
HTPEM FC System- pure hydrogen
![Page 6: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/6.jpg)
6
©SJA 2007
Previous work – Initial experimental results
Stack temperature profile identification
![Page 7: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/7.jpg)
7
©SJA 2007
Fuel cell stack energy balance
Energy balance :
Fuel cell heat input :
External heat input :
Forced Convection :
Heat Conduction :
Natural Convection :
PWMtotalexternalin DPQ ,
![Page 8: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/8.jpg)
8
©SJA 2007
Manifold and gas channel temperature
T
xmanifold
endmiddle
front
Tmanifold,in,front
Tmanifold,in,middle
Tmanifold,in,end
T
xchannel
Tmanifold,in,front + Tmanifold,in,middleTchannel,in,front =
2
Texit,channel,middleTexit,channel,front Texit,channel,end
![Page 9: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/9.jpg)
9
©SJA 2007
Model assumptions
∙ Quasi-steady-state : Constant surface temperature.∙ Fuel cell stack modelled as three lumps.
∙ Constant Urev of 1.2V.
∙ Fuel cell heat generation calculated at steady-state.∙ No axial and in-plane heat conduction between lumps.∙ Additional heating in inlet plate and BPP junction modelled as small
constant gain.∙ Heat transfer in the MEA is neglected.∙ Hydrogen heating and cooling effects neglected.∙ Constant air mass flow in channels, consumption subtracted.∙ Small natural convection term added.
![Page 10: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/10.jpg)
10
©SJA 2007
HTPEM FC stack temperature control
SystemController
TmeasuredTreference
Ublower
Ireference
I->mAir
FC air flow – PI controller with Current feedforward
Stack temperature 160-180 oC, what Tmeasured should be used?
+
+-
+
![Page 11: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/11.jpg)
11
©SJA 2007
Typical stack temperature control case
Middle temperature controlled End temperature controlled
Initial heating followed by 20 A load step.
![Page 12: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/12.jpg)
12
©SJA 2007
Model validation - Electrical heating
Experiment :
400 W heating
Simulation :
350 W heating
![Page 13: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/13.jpg)
13
©SJA 2007
Model validation – Constant current
Experiment :
20 A load
Simulation :
1500 W heating,
20 A load
![Page 14: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/14.jpg)
14
©SJA 2007
Model validation – Pulsating air flow
Operation :
small current ramp,
20 A load
air flow pulsing
no controls
![Page 15: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/15.jpg)
15
©SJA 2007
Example of experimental data
![Page 16: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/16.jpg)
16
©SJA 2007
Conclusions and future work
Conclusions∙ Developed model can with good agreement predict fuel cell stack temperature
dynamics.∙ Developed model can within acceptable ranges predict the steady-state values
of the fuel cell stack temperatures.∙ The modelled exhaust temperature must be improved for use as a direct
control feedback.∙ Minimization of measured temperatures should be examnied using model
based control.Furture Work∙ Manifold and channel temperature dynamics∙ Air flow subtraction along the channel∙ Discrete (at cell level) model∙ Model validation on 1 kW HTPEM stack with other geometry
![Page 17: ©SJA 2007 1 Søren Juhl Andreasen and Søren Knudsen Kær Aalborg University Institute of Energy Technology Dynamic Model of High Temperature PEM Fuel Cell.](https://reader036.fdocuments.net/reader036/viewer/2022062519/5697bfc81a28abf838ca8649/html5/thumbnails/17.jpg)
17
©SJA 2007
Thank you for your attention!