Sitrans F, Pliant General Siemens, En
Transcript of Sitrans F, Pliant General Siemens, En
-
7/31/2019 Sitrans F, Pliant General Siemens, En
1/16
SITRANS F Flowmeters
The flow force
sitrans
-
7/31/2019 Sitrans F, Pliant General Siemens, En
2/16
2
Accurate flow speed measurement of liquids with
varying consistencies, of gases or vapors plays a
highly important role in process automation.
With its time-tested SITRANS F family, Siemens has
developed a comprehensive product program rang-
ing from simple flow indicators to highly sophistica-
ted, bus compatible measurement converters.
The optimal flowmeter for all special measurement
tasks this is the motto Siemens has chosen to
describe a comprehensive program of powerful
devices utilizing various measuring methods
magnetic-inductive, ultrasound, mechanical or based
on the Coriolis massflow principle.
Whether for measuring media temperatures of
238 F to +482 F (150 C to +250 C), conductive
or non-conductive materials measurements, utiliza-
tion in standard or hazardous environments
Siemens flow product portfolio offers the right flow
meter. Providing consultation to customers from
the planning phase, they are happy to accompany
projects through to installation if so desired.
Comprehensive flowmetering
competence
-
7/31/2019 Sitrans F, Pliant General Siemens, En
3/16
-
7/31/2019 Sitrans F, Pliant General Siemens, En
4/16
-
7/31/2019 Sitrans F, Pliant General Siemens, En
5/16
-
7/31/2019 Sitrans F, Pliant General Siemens, En
6/166
SITRANS F M MAGFLOMAG 1100
SITRANS F M 711/S
SITRANS F M F5
SITRANS F M MAGFLOMAG 1100 F
Process adapters
Pharmaceutical, Food and Beverage
Hygiene is priority one in the pharmaceutical, food and beverage industries. Thisdirectly impacts the utilized measurement devices. These must be easy-to-clean,
contain no crevices, and be equipped with special seals and process connections.
Not to be overlooked also is the need for high temperature resistance; e.g. during
steam cleaning.
SITRANS F M MAGFLO MAG 1100
High temperatures, as well as aggressiveand abrasive media have no influence on
the operability of the MAG 1100.
1/44 (DN 6100) median flange
version
ceramic metering pipe (Al2O3) or PFA platinum or Hastelloy electrodes
SITRANS F M 711/SThe SITRANS F M 711/S flowmeter was
specially designed for standard applica-
tions. Due to its extreme light weight,
the median flange version flowmeter issuperbly suited for integration in plastic
pipes. Installation between steel flanges
also poses no problems.
metering pipe made of PVC and PVDF
1/24 (DN 15100) permanently installed grounded rings
SITRANS F M F5The metering sensor F5 measures mi-
nutest flows beginning at 00.013 GPM
(03 l/h)
ceramic metering pipe (ZrO2),
1/161/2 (212 mm)
platinum electrodes
thread, flange and sanitary process con-
nections available in various material
forms
SITRANS F M MAGFLO MAG 1100 F
The MAG 1100 F was specially designed
for the food and beverage industry. Itpassed the 3A and EHEDG hygienic test
and fulfills all sanitary standards. With its
variable connectivity options, it is also
ideally suited for the pharmaceutical in-
dustry.
AISI 316 stainless steel housing 1/24 (DN10DN100 mm)
PFA or ceramic Al2O
3metering pipe
Special seal for hygienic applications,
3A- and EHEDG approved construction
Easy-to-clean NEMA 4x/IP67 protection class, option-
ally upgradable to NEMA 6/IP68
Variable process connection options
according to customer demands
-
7/31/2019 Sitrans F, Pliant General Siemens, En
7/16
7
SITRANS F M MAGFLO MAG 5100 W
SITRANS F M S1 and S2
A Solution for every application just choose the size
Water
Water is one of the most precious resources on our planet. A highly accurate recording
capability of consumption levels is indispensible. This also presupposes the option of on-
site assessment with utilized measurement devices. Sanitary metering pipe linings for use
in drinking water systems are just as indispensible as abrasion and chemical resistant liningsused in sewage facilities.
SITRANS F M MAGFLO MAG 5100 WWith its patented composite elastomer
lining, the MAG 5100 W is well suited for
all water applications. Customers need
only specify the bore diameter and pres-
sure rating and we supply the rest.
Available in diameters ranging from
148 (DN 25 to DN 1200)
Available in PN 6, PN 10, PN 16, PN 40,
ANSI class 150 lbs and AWWA C-207
The hard elastomer lined pipe provides
interior diameter stability throughout
the entire temperature and pressurerange, thereby assuring accurate repro-
duction
The soft elastomer coating offers high
abrasion resistance, making gaskets
virtually superfluous
Stainless steel measurement electrodesand integrated grounded electrodes
High resistance to a wide range of
chemicals
Drinking water quality approved
Conforms to OIML R49 and ISO 4064
standards
Magnetic-inductive flowmeters exact pinpoint measurement of flow
velocity
installation with weld joints
can (optionally) be extended across the
entire bore diameter (up to 80/
DN 2000) for flow profile measurements
part replacement under pressure withbasic tools possible (optional)
can be combined with the converter
INTERMAG 2
-
7/31/2019 Sitrans F, Pliant General Siemens, En
8/16
-
7/31/2019 Sitrans F, Pliant General Siemens, En
9/16
9
SITRANS F US SONOFLO SONOKIT
SITRANS F US SONOFLO SONOCELL
SITRANS F US SONOFLO SONO 3300 CT
SITRANS F US SONOFLO SONOCELL
Battery-powered ultrasonic flowmeters
for water and irrigation applications
Accuracy: better than +/ 1% of current
measurement value
Nominal pipe size:
3 to 16 (DN 80DN 400)
A 3.6 volt battery with a lifespan of
> 8 years. 24 volt or 230 volt powersupply optional
The integrated LCD display indicates and
stores current measurement values.
Measurement data can be transferredto a handheld INFOLOG or PC via the
infrared interface
Water
Flow rate measurements play an increas-
ingly important role in the water industry.Measuring devices frequently require
retrofitting, without the possibility of
emptying the pipeline.
The irrigation of agricultural surfacesalso takes on ever greater significance.
Power sources are rarely available at the
measuring point. In this case, battery-
powered devices handle the equal water
distribution.
SITRANS F US SONOFLO SONO
3300 CT Reliable district heating
measurementBore diameters: 248 (DN 501200)
The SONO 3300 CT ultrasonic meters
were specially designed for exact high-
resolution energy measurement of high-
performance, water-based district heatingsystems, i. e. for power stations, energy
transfer stations or distribution nets.
The meters are designed for measure-
ments subject to calibration standards andapproved for OIML R75, Class 4 and PTB,
Class C.
SITRANS F US SONOFLO SONOKITThe SONOKIT offers a simple, accurate
alternative to conventional flowmeters.
This practical assembly kit contains ev-
erything needed for the installation of a
flowmeter using basic tools.
SONOKIT simplifies retrofitting for virtually
any type or size of pipe, thus enabling an
extremely cost-effective solution, even for
water pipelines of larger dimension. In-
stallation can also be undertaken on filledpipes and under pressure: hot tap instal-
lation. Cost-effective solution contains all of
the necessary components for retrofit-
ting
SONOKIT is easily installed in pipelinesizes 8 to 160 (DN 200 to DN 4000)
without process shutdown or flow inter-
ruption
High accuracy the bigger the bore,
the more accurate the result
Solid installation with no moving partsfor 100 % maintenance free flowmeter-
ing at no loss of pressure
SONOKIT is available with signalconverters in NEMA 6 (IP67) housings;
IP68 installation optionally available
Automatic calculation of the calibrationfactor when pipeline geometry data is
entered into the signal converter
-
7/31/2019 Sitrans F, Pliant General Siemens, En
10/16
10
SITRANS F C MASSFLO MASS 2100with adapter element
SITRANS F C MASSFLOMASS 6000, IP20
SITRANS F C MASSFLOMASS 2100
SITRANS F C MASSFLOMASS compact
SITRANS F C MASSFLOMASS compact Ex d
SITRANS F C
Mass flowmeters
Functional principle: the measured media
is channeled through a defined pipeline
and accelerated vertically to the flow di-rection. The Coriolis induced energy cre-
ates vibrations of the pipeline, which can
either be measured at the pipeline itself
or at the fittings. The measured vibration
is proportional to the mass flow rate.
Multi-parametric process informationIn addition to conducting highly accurate
mass flow measurements, SITRANS F C
MASSFLO also measures the exact volume
flow, density, fraction flow and tempera-
ture. This information provides vital dataon the process status, making additional
measuring devices virtually superfluous.
The density is measured with a margin
of error of less than 0.09346853 ounces/
gallon (0.0007g/cm3), and the tempera-ture with a margin of error of less than
41 F (0.5 C).
Easy to install Maximal durabilityMASSFLO flowmeters are designed for
easy installation and optimal durability
against external vibrations. Upstream ordownstream pipe runs are not required.
Modularity on a new level
MASSFLO flowmeters are fully user configurable both
in terms of software and hardware. Thanks to an Add-on module, the intelligent USM II Universal Signal
module platform allows for retrofitting of desired
individual functions. Once installed, the module is
automatically identified and programmed to factory
settings via the SENSORPROM flow storage unit.
In addition to its modularity capabilities, the USM II
platform handles a wide range of communication
protocols, e.g. HART, PROFIBUS or Can-Open.
The multi-purpose modularity capabilities also find
expression in the unique interface between the mea-
surement sensor and signal converter: the standardizedplug connection is identical for sensor and converter
types.
-
7/31/2019 Sitrans F, Pliant General Siemens, En
11/16
11
SITRANS F C MASSFLO
MASS 2100 Di 1.5
The MASSFLO provides reliable measure-ments of the lowest flows.
Application examples include:
Tests fuel nozzles
Refrigerant charging of hermetically
sealed compressors Metering of flavors and additives in the
food and beverage industry
Highly exact measurement of pharma-
ceutical products
Measurement of essential oils and fra-
grances in the cosmetic industry
Highly accurate gas measurement
Safety, absolute measurement accu-
racy and sustained high-level qualityare of utmost importance for the
chemical industryThe SITRANS F C MASSFLO ideally fullfillsall of these demands. Highest measure-
ment accuracy of 0.1%, a robust industrial
design and modular design for easy in-
place upgrade are only a few of the units
highlights:
The stainless steel housing ensures
optimal operations cost management
The integrally safe keypad enables Ex d
converter operation directly in hazard-
ous environments
Add-on modules can be retrofitted
directly onto the Ex d converters (withflameproof enclosure)
Safe and robust sensor design allows
for maximal pressure load up to
5,945 psig/410 bar
SITRANS F C MASSFLO
MASS 6000 Ex d
1 The integrally safe keypad and displayoffer optimal functionality and pro-gramming flexibility in hazardous en-vironments
2 Add-on modules can be retrofitted toexisting flowmeters, thereby providingcommunications capabilities and otherfunctions to meet current and futuredemands.
3 SENSORPROM technology enables:factory preprogramming of calibrationdata with all user measurements andsettings being automatically stored.The automatic reprogramming of repla-
ced signal converters is performed inless than five minutes
4 The signal converters are designed withintrinsically safe features according toEx ia IIC, thereby conforming to thetoughest industry quality standards
1 The meter is installed with a singlequick release clamp fitting and a singlemulti-plug connector fast and cost-effective
2 Plug and play installation and startupof the mass flowmeter is completed inless than 10 minutes
3 Maximal durability in combinationwith the balanced pipe loops, the centerblock concept ensures reliable long-term stability, eliminating influencesfrom process conditions altogether
4 Single-pipe design ensures optimalhygiene and safety. All of our sensorsconsist of a single pipe without anywelded joints, thereby ensuring thatsteam or CIP cleaning can be carriedout with confidence
SITRANS F C MASSFLOMASS 2100 Di 1.5
SITRANS F C MASSFLOMASS 6000 Ex d
-
7/31/2019 Sitrans F, Pliant General Siemens, En
12/16
12
SITRANS F C MASSFLO MASS compact
Reliable performance delivers
dependable resultsExact recipe control is an indispensible
requirement in the pharmaceutical, food
and beverage industry requiring reliable
multi-parametric measurement, uniform
inline mixing and adaptive batching athigh speed. The SITRANS F C 6000 Ex d is
unique in its sophisticated integral batch
control function. Its exceptional features
include:
Adaptive batching control enablesextremely accurate and stable batching
under all operating conditions
Multi-parametric process information
for mass flow, volume f low, density,
temperature and fraction flow these
are all standard measurement functions
Accurate dosing of additives and ingre-
dients from a few grams per hour to
the measurement of several tons per
hour
-
7/31/2019 Sitrans F, Pliant General Siemens, En
13/16
-
7/31/2019 Sitrans F, Pliant General Siemens, En
14/16
14
Rotary piston meters are designed toensure the highest level of reliability,durability and accuracy. For this reason,they find great utilization in dosingautomated systems for the productionof precise mixtures in the pharmaceuticaland food industry.
Technical Data from 0.05 to 265 US GPM (0.2 to 1000 l/min) from 1/2 to 3-Flange (DN 15 to DN 80) from 73 to 914 psi (PN 4 to PN 63)
SITRANS F R
Rotary piston meters
Rotary piston meters function reliably and
provide precise measurements, even in
the most difficult applications and extreme
conditions:
Aggressive or high-viscosity media have
no influence on measurement accuracy
Well suited also for demanding media
measurements such as alcohol, hot
bitumen, hydrocloric acid, resins, oils,
cocoa butter, offset colors, soda lye orfood
For this reason, rotating piston meters
continue to be indispensible in the chemi-
cal, petrochemical, pharmaceutical, ener-
gy and food industry to thi s day.
Technical highlights:
Ideally suited for calibratable measure-
ments in official communications
Measurement of high- and low-viscosity
liquids
Measurements at high operating tem-
peratures up to 572 F (300 C) Measurements and dosages without
auxiliary energy sources
Mobile utilization, e.g. on vehicles
Optionally available with external heat-
ing source
Easy installation, because in- and out-
flow runs not required
Completely independent of flow profile,
conductivity or damping
Rotary piston meters from Siemens are bestsellers. Millions have been sold over
the past decades, and yet they have lost none of their luster. The numerous
advantages their conventional mechanical measuring technology offers include
exceptional reliability, precision and a robust design.
SITRANS F R drum type m eter
A highly accurate device for measuringalcohol-water mixtures and for determin-ing the level of alcohol content the
only device with approval of the BusinessRegulatory Agency of the Federal Republicof Germany.
SITRANS F R lubrication meter forstationary operation
Whether officially calibrated or not you can count on the robust, precisionqualities of these time-tested measuringdevices!
SITRANS F R rotary piston meter (pistol-gripmeter)
-
7/31/2019 Sitrans F, Pliant General Siemens, En
15/16
15
SITRANS Flowmeters
Quality that you can rely on. We guarantee it!
How we calibrate:SITRANS F flowmeters are individually
calibrated at our calibration facilities. Thecalibration data of all electronic flow sen-
sors is stored on-site for future reference.
Flow measurement accuracy is also safe-
guarded if the converter is replaced. All
sensor data is automatically transferredto the replacement converter via SENSOR-
PROM or smartPLUG. In addition, each
converter is subjected to an electronic test
to ensure correct conversion of the sensor
signal. This allows for any converter to beconnected to any sensor of the same prod-
uct series. That is to say that the productportfolio is highly flexible. Siemens me-
chanical flowmeters are individually cali-
brated and rigorously tested before leavingthe factory.
Several of our calibration laboratories are
EN 45001 accredited general criteria for
testing laboratory operations , and rec-
ognized, among others, by UKAS andDANAK.
Flowmeters for Custody TransferSITRANS F M MAGFLO flowmeters are type
approved for PTB (type approvals for coldwater), OIML R75 and OIML R117. Meters
approved for custody transfer are standard
flowmeters which have been calibrated
in an accredited calibration facility and
sealed to avoid readjustment of the meterafter calibration.
SITRANS F US SONOFLO ultrasonic flow-
meters have type-specific approvals for
custody transfer flow measurement ac-
cording to PTB.
SITRANS F R Rotary piston meters andlubricating oil have type-specific approvals
for custody transfer measurement ac-
cording to PTB
On-site accuracy verification
Siemens SITRANS F M MAGFLO magnetic-inductive flowmeters are tested on-site.
The SITRANS F M MAGFLO flowmeters are
verificator tested. Trained and authorized
Siemens staff inspect the entire signal
chain of the flowmeter and secure itsfunctions according to specifications. A
certificate of inspection detailing the in-spection results is issued.
The SITRANS F M INTERMAG converter
contains an internal diagnostic system for
monitoring the entire system, includingflow sensors and cabling. Even deviations
in the converter due to systems wear are
reliably identified and require no external
tools.
LICIS
-
7/31/2019 Sitrans F, Pliant General Siemens, En
16/16
PUBL
Subjectto
changewithoutpriornotice05/04|OrderNo.E20001-A300-P710-V1-7600|DISPO27900|41C8621PI.P3.ALLG.52.4.10W
S05046.0|PrintedinGermany|SiemensAG2004To locate your Siemens partners worldwide ...
Siemens Flow Instruments A/SDK-6430 NordborgNordborgvej 81Denmark
www.siemens.com/processautomation
... contact us at our homepage
www.siemens.com/processinstrumentation
and look under Contact
The information provided in this brochure contains merely generaldescriptions or characteristics of performance which in case ofactual use do not always apply as described or which may changeas a result of further development of the products. An obligationto provide the respective characteristics shall only exist if expresslyagreed in the terms of contract.
SITRANS, MAGFLO, MASSFLO, SONOFLO, SENSORPROMund TRANSMAG are registered trademarks of Siemens.Other designations used in this publication may betrademarks whose use by third parties for their ownpurposes can violate the rights of the owners.