SITE PLAN - Solution4Building · 2018. 5. 17. · acheive adecuate screed thickness and falls to...
Transcript of SITE PLAN - Solution4Building · 2018. 5. 17. · acheive adecuate screed thickness and falls to...
REFURBISHMENT TO
EXISTING TOILET BLOCK
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:22 AM
1 : 1
0
OKA PROJECT No.18026 A1.01
SITE PLAN
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A1.01
Designer
FI
Approver
March 2018
BMW 912318B45040
NTS
SITE PLAN
REV. DATE DESCRIPTION DWN CHECK
- 04.04.2018 ISSUED FOR COMMENTS SRW FI
A 13.04.2018 ISSUED TO CONSULTANTS SRW FI
0 04.05.2018 TENDER SRW FI
A701
1
2
4
A701 7
6
AA4.01
BA4.01
CA4.02
Male
Female
Female Toilets
LobbyMeeting Room
Male Toilets
LobbyStore Room
Staff Toilet
Staff Toilets
Lobby
Duct Duct
New Ceramic Tiles
New Ceramic Tiles
New Urinal recessed into floor slabNew Hand
Washing
Trough
Ambulant
Toilet
WCWCWCWCWCWCWCWCWCWC
Ambulant
Toilet
New Hand
Washing
Trough
New 2143 H brick wall
OPAQUE FILM TO THE INSIDE OF
WINDOW AT STORE ROOM
NEW 1000mm HIGH DADO WALL
TO CONCEAL PIPEWORK
NEW COLUMNS TO S.E. DETAILS
COL COLCOL
COL
Redundant Room
Room
DA4.02
A702
3
4
1
2A701
4.1
A702
1.1
5
A702 4.1
3
EA4.03
NEW STUD WALL ABOVE TO CONCEAL EXISTING WINDOWS
FA4.03
MODIFY EDGE OF CONCRETE SLAB TO BE ABLE
TO TILED THE FRONT FACE AND MANTAIN
SLIDING DOOR TRACK
MODIFY EDGE OF CONCRETE SLAB TO BE ABLE
TO TILED THE FRONT FACE AND MANTAIN
SLIDING DOOR TRACK
RWP RWP RWP
FLOOR WASTE
FLOOR WASTE
FALL
FALL
FALL
FALLFALL FALL
FALLFALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FALL
FW
FW
FW FW
FW
FW
FLOOR NOTES:
EXISTING FLOOR SLAB TO BE SCABBLED AND CUT TO
ACHEIVE ADECUATE SCREED THICKNESS AND FALLS TO NEW
FLOOR WASTES. MANTAIN EXISTING FLOOR LEVELS AT
LOBBIES.
NEW URINAL AREA: CUT SLAB TO FORM NEW MORTER BED TO
SUPPORT URINAL TRAY AND PREVENT FLEXING. FOLLOW
URINAL MANUFACTURER'S RECOMMENDATIONS.
343090
wal
l16
65
Ambulant toilet min 900 clear907EQ EQ EQ
SURFACE MOUNTED
CONDUITS TO BE
CHASED INTO THE
WALL . MAKE GOOD
AND PAINT
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:25 AM
1 : 50
0
OKA PROJECT No.18026 A2.01
PROPOSED FLOOR PLAN
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A2.01
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50A3.01FLOOR PLAN1
REV. DATE DESCRIPTION DWN CHECK
- 04.04.2018 ISSUED FOR COMMENTS SRW FI
0 04.05.2018 TENDER SRW FI
CA4.02
Meeting Room Store RoomMale Toilets
LobbyFemale Toilets
Lobby
Female Male
DuctDuct
Staff Toilet
EA4.03
REMOVE URINAL
DEMOLISH THIS WALL COMPLETE
REMOVE EXISTING TOILET PARTITION COMPLETE
FA4.03
MODIFY EXISTING EXTERNAL CLADDING
ABOVE LOWER ROOF IN ORDER TO INSTALL
NEW ROOF OVER TOILETS AND PROVIDE
FLASHING AND SUPPORT STRUCTURE
DEMOLITION NOTES
1. ROOF: REMOVE EXISTING ROOF, ROOF STRUCTURE, DOWN PIPES AND GUTTERS OVER
TOILET'S ROOMS ONLY
2. CONCRETE WINDOW SILL. INSPECT AND CAREFULLY SCABLE , GRIND CONCRETE SILL TO
EXPOSED STEEL REINFORCEMENT. REMOVE WHERE IS CORRODED, REINSTATE AND MAGE
GOOD.
3. REMOVE EXISTING COVED EDGE OF TOILETS WALL AND FLOOR JUNCTION.
4 REMOVE EXISTING FLOOR WAISTS.
5. GENERALLY REMOVE ALL TOILETS PANS, BASINS URINAL AND REDUNDANT PIPES WORK.
6. REMOVE ALL EXISTING TILES.
7. REMOVE ALL EXISTING TOILET'S PARTITIONS.
8. REMOVE ONE BRICK WALL IN MALE TOILET AS SHOWN ON DRAWING.
9. SOUTH EAST SIDE ONLY: REMOVE EXISTING SECURITY SCREENS IN STORE ROOM AND
MEETING ROOM EXISTING WINDOWS. MAINTAIN SECURITY TO THESE WINDOWS DURING
CONSTRUCTION.
10. REMOVE AND REPLACE WITH NEW DAMAGED FLASHING AROUND WINDOWS.
11. REMOVE AND REPLACE MESH IN VENTILATION SLOTS OF EXISTING WINDOWS. NEW MESH TO
BE STAINLESS STEEL SECURITY MESH AS SPECIFIED.
12 EXISTING FLOOR SLAB TO BE SCABBLED AND CUT TO ACHEIVE ADECUATE SCREED
THICKNESS AND FALLS TO NEW FLOOR WASTES. MANTAIN EXISTING FLOOR LEVELS AT
LOBBIES.
NEW URINAL AREA: CUT SLAB TO FORM NEW MORTAR BED TO SUPPORT URINAL TRAY AND
PREVENT FLEXING. FOLLOW URINAL MANUFACTURER'S RECOMMENDATIONS.
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:26 AM
1 : 100
0
OKA PROJECT No.18026 A2.02
DEMOLITION PLAN
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A2.02
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 100A3.01
DEMOLITION PLAN1
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
CA4.02
EA4.03
EXISTING ROOF. NO CHANGES
FA4.03
RF-01
RF-02RF-03
RF-03RF-03
RF-02
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:29 AM
1 : 100
0
OKA PROJECT No.18026 A2.03
ROOF PLAN
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
Author
A2.03
Designer
Checker
Approver
March 2018
BMW 912318
SCALE: 1 : 100A3.01ROOF PLAN1
NEW COLORBOND KLIPLOCK ROOF TO 1.5° PITCH
COLORBOND RIDGE FLASHING
NEW GUTTER AND DOWN PIPE DISCHARGE
OVER EXISTING ROOF BELOW
NEW GUTTER FIXED TO END OF
NEW COLORBOND KLIPLOCK
ROOF SHEETING
Keynote Legend
CODE DESCRIPTION
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
RF-03 PAINTED UPVC DOWNPIPES AS HYDRAULICSCONSULTANT DWGS
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
CA4.02
EA4.03
Meeting Room
Female Toilets
Lobby
Male Toilets
LobbyStore Room
Staff Toilets
Lobby
Staff Toilet
Female
NO
CLG
NO
CLG
MRFPB
2400
MRFPB
2400
MRFPB
2070MRFPB
2070
FA4.03
MRFPB
2212
CEILING NOT MODIFIEDCEILING NOT MODIFIEDCEILING NOT
MODIFIED
CEILING NOT
MODIFIED
CORNICE AS SPECIFIED
NO
CLG
EFPB
2700
NO CEILING
CEILING MATERIAL
HEIGHT ABOVE FLOOR LEVEL
MRFPB MOISTURE RESISTANT FLUSHED PLASTERBOARD
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:30 AM
1 : 100
0
OKA PROJECT No.18026 A2.04
CEILING PLAN
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
Author
A2.04
Designer
Checker
Approver
March 2018
BMW 912318
SCALE: 1 : 100A3.01
REFLECTED CEILING PLAN1
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
CEILING LEGEND
Ground Floor
Ceiling
RL 2.400
NEW WALL CLAD WITH CFC. PAINT FINISH. REFER TO SECTION DETAILS ON DRAWING A5.03
NEW COLORBOND FASCIA GUTTER , TO MATCH EXISTING , AS BARGE BOARD.
NEW COLORBOND KLIPLOCK ROOF1.5 DEGREES PITCH
NEW PAINTED RAIN
WATER PIPE
ALL EXISTING WINDOWS TO
REMAIN. CLEAN . REPLACE
DAMAGED PUTTY. MAKE GOOD
AND PAINT
NEW GRILLE TO MECHANICAL CONSULTANT DETAILS
608
877MODIFY EXISTING EXTERNAL CLADDING TO
INSTALL NEW FLASHING OVER NEW ROOF
3A3.01
EXISTING FACE BRICK WALLS; CLEAN
BRICK WORK, REMOVE MORTAR ON
BRICK SURFACE, RE-POINT WHERE IS
REQUIRED. MORTAR DETAILS TO
MATCH EXISTING.
Ground Floor
Ceiling
RL 2.400
EXTEND NEW
EXTERNAL STUD WALL
OVER WINDOW TO
COMMS ROOM
WINDOWS
REPLACE EXISTING DOWN PIPES IN THIS CORNER
NEW STUD WALL FIXED TO FRONT OF EXISTING WINDOWS
RF-03
RF-01
RF-02
RF-03RF-03
DISCHARGE DUCT AREA 0.353 sq.m.
DUCT WALL BEHIND
LOUVRE TO FULL WIDTH OF EXISTING WINDOW
LOUVRE TO EQUAL WIDTH OF WINDOW BELOW
AND TO MAXIMUM HEIGHT: APPROX 270mm
MANTAINING WINDOW SUPPORT. (ANGLE)
270
ALTERNATIVELY , IF PREFERRED, CUT OUT
WINDOW HEAD FRAME AND ITS STRUCTURE,
MAKE GOOD. STRUCTURE INTEGRITY TO
REMAIN AND FRAME AROUND TO FORM ONE
LOUVRE PANEL.
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:53 AM
As indicated
0
OKA PROJECT No.18026 A3.01
ELEVATIONS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A3.01
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 100
North East Elevation
SCALE: 1 : 100
South East Elevation
EXISTING ROOF,GUTTER TO REMAIN. EXISTING
DOWN PIPES TO BE REPLACED WITH NEW DOWN
PIPE AND SPREADER OVER NEW ROOF BELOW.
NEW ROOF OVER
TOILETS AREA
PAINTED CFC TO NEW WALL ABOVE
WINDOWS
EXISTING WINDOWS: CLEAN REPLACE DAMAGE PUTTY.
REPLACE EXISTING MESH WITH STAINLESS STEEL SECURITY
MESH AS SPECIFIED. MAKE GOOD , PAINT.
NEW RAIN WATER PIPES CONNECTED TO
NEW SOAKWELL TO HYDRAULIC
CONSULTANT DETAILS
SCALE: 1 : 20A3.01Detail 33
EXISTING FACE BRICK WALLS; CLEAN BRICK WORK, REMOVE
MORTAR ON BRICK SURFACE, RE-POINT WHERE IS REQUIRED.
MORTAR DETAILS TO MATCH EXISTING.
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
Keynote Legend
CODE DESCRIPTION
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
RF-03 PAINTED UPVC DOWNPIPES AS HYDRAULICSCONSULTANT DWGS
Ground Floor
EXISTING ROOF TO REMAIN
NEW FRAMED CFC LINED WALL
REFER TO S.E. DETAILSNEW COLORBOND KLIPLOK ROOF SHEETING ON
NEW ROOF STRUCTURE TO 1.5 DEGREES PITCH
NEW CEILING AT 2.4M
NEW FULL HEIGHT WALL TILES
NEW TOILETS FITTINGS
NEW RAIN WATER PIPES
NEW BRICKWORK EXTENSION
NEW PLASTERBOARD
LINED WALL OVER
WINDOW
1A5.01
2A5.01
Ceiling
RL 2.400
Duct
Store Room
ST-03
RF-01
1000mm H DADO WALL. TILED
FULL HEIGHT TILES
1900
200
1700
1000mm H DADO WALL. TILED
BULKHEADST-01 ST-01
2070
2A5.02
RF-01
RF-02
CG-02
MODIFY EXISTING RAIN WATER PIPES TO
DISCHARGE WATER FROM EXISTING HIGHER
ROOF INTO NEW ROOF WITH A SPREADER
NEW MIRROR
2070
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:32 AM
1 : 50
0
OKA PROJECT No.18026 A4.01
SECTION
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
Author
A4.01
Designer
Checker
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50A2.01SECTION A-AA
SCALE: 1 : 50A2.01SECTION B-BB
Keynote Legend
CODE DESCRIPTION
CG-02 COVED CORNICE AS SPECIFIED
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
ST-01 RHS TO S.E. DETAILS
ST-03 PURLIN TO S.E. DETAILS
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
BA4.01
NEW WALLS IN FRONT OF
EXISTING WINDOW .
NEW ROOF:
COLORBOND KLIPLOK
TO 1.5 DEGREES PITCH
NEW SKIRTING TILES TO LOBBY
NEW MIRROR
NEW TROUGH AND TAPS
CONCRETE SILL CUT
& REPLACED
WHERE DAMAGED.
REFER TO
ELEVATION
DRAWINGS NOTES
Female Toilets
Lobby
Female
NEW PAINT
Ceiling
RL 2.400
BU
LKH
EA
D20
70
NEW BULKHEAD
CG-02
RF-01
RF-02ST-04
ST-01
TILE AROUND NEW BRICK PIERS
Ground Floor
BA4.01
Ceiling
RL 2.400
RF-03
RF-02
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:34 AM
1 : 50
0
OKA PROJECT No.18026 A4.02
SECTIONS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A4.02
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50A2.01Section C-CC SCALE: 1 : 50A2.01
Section ElevationD
APPLY OPAQUE GREY
FILM TO EXISTING
GLAZING
NEW EXTERNAL STUD WALL
CLADD WITH 13MM MOISTURE
RESISTANT COMPRESSED
FIBRE CEMENT. PAINT FINISH
NEW EXHAUST GRILLE TO
MECHANICAL CONSULTANT
DETAILS
NEW CFC CLAD WALL OVER
EXISTING WINDOWS
INTERNALLY WITH MOISTURE
RESISTANT PLASTERBOARD,
AND EXTERNALLY WITH
COMPRESSED FIBRE CEMENT.
PAINT FINISH.
EXISTING
COMMS ROOM
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
Keynote Legend
CODE DESCRIPTION
CG-02 COVED CORNICE AS SPECIFIED
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
RF-03 PAINTED UPVC DOWNPIPES AS HYDRAULICSCONSULTANT DWGS
ST-01 RHS TO S.E. DETAILS
ST-04 C SECTION TO S.E. DETAILS
EXISTING
WINDOWS TO BE
REFURBISHED
Ground Floor
Ceiling
RL 2.400
NEW WALL ABOVE EXISTING WINDOWS
MECHANICAL DUCT AREA
NEW BULKHEAD
NEW STUD WALL IN FRONT AND OF EXISTING WINDOW
PLASTERBOARD ON FURRING
CHANELS FIXED TO EXISTING
WINDOW FRAME
BU
LKH
EA
D20
70
BOTTOM OF BEAM
CEILING
RF-01
RF-02
RF-03
BULKHEAD
TILED SKIRTING
NEW PAINT TO EXISTING WALL
MAKE GOOD WHERE IS REQUIRED
CT-02
CT-01
PT-03EXISTING WINDOWS TO
BE REFURBISHED
CG-02
RF-01
EXISTING DOOR TO REMAIN
NEW PAINTED
CFC FIXED TO
15mm TOP HATS
Ground Floor
CE
ILIN
G22
12
1A5.02
Staff Toilet
Staff Toilets
LobbyStore Room
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:36 AM
1 : 50
0
OKA PROJECT No.18026 A4.03
SECTIONS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A4.03
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50A2.01Section E-EE
SCALE: 1 : 50A2.01Section F-FF
Keynote Legend
CODE DESCRIPTION
CG-02 COVED CORNICE AS SPECIFIED
CT-01 CERAMIC WALL TILE GLOSS NON RECTIFIED300X600
CT-02 CERAMIC FLOOR TILE & SKIRTING R10/P3 300X300
PT-03 WALL PAINT - DULUX WASH & WEAR
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
RF-03 PAINTED UPVC DOWNPIPES AS HYDRAULICSCONSULTANT DWGS
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
EXISTING ROOF AND GUTTER TO REMAIN
NEW FLASHING
NEW 64MM STUDS WALL FIXED TO EXISTING WINDOW FRAM AND ROOF.
CLADDING: COMPRESSED FIBRE CEMENT SHEETING. PAINTED.
NEW DOWN PIPES AND SPREADER.
NEW COLORBOND FLASHING
NEW ROOF COLORBOND KLIPLOCK: 1.5 DEGREES PITCH
NEW PURLINS TO S.E. DETAILS
NEW BEAM (RAFTER) TO S.E. DETAILS
NEW PAINTED
PLASTERBOARD FIXED TO
TOPHATS.
TOPHATS FIXED TO EXISTING
WINDOW FRAMES.
EXISTING WINDOWS TO
REMAIN
NEW CEILING 2.4M ABOVE
FINISHED FLOOR LEVEL
EXTEND BRICK WALL VERTICALLY
NEW WALL TILES TO FULL HEIGHT.
Ceiling
RL 2.400
STEEL PLATE WELDED TO
RAFTER AND FIXED TO WALL
TO S.E. DETAILS
DUCT
ST-03
Ceiling
RL 2.400
NOTE 1
TOP HATS
2 C SECTION WELDED TOGETHER. TO
S. E. DETAILS
PAINTED CFC
NEW COLORBOND KLIPLOCK 1.5° PITCH
BULKHEAD
NEW COLUMN ABOVE BRICK
PIER . PAINTED
NEW TILING
COLORBOND FLASHING FIXED TO C SECTION
NEW BRICK AROUND NEW
COLUMN. TILED PIER
NEW STEEL RAFTER TO S.E. DETAILS
RF-02
RF-01
TILE OVER PIER
NOTE 1
CAREFULLY SCABLE, GRIND BACK
CONCRETE SILL TO EXPOSED
REINFORCEMENT. REMOVE WHERE IT IS
CORRODED , REINSTATE AND MAKE
GOOD.
REFER TO S.E. DETAILS
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:37 AM
As indicated
0
OKA PROJECT No.18026 A5.01
DETAILS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
Author
A5.01
Designer
Checker
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 10A4.01Section A-A - Detail 11
SCALE: 1 : 10A4.01Section A-A - Detail 22
REMOVE EXISTING
SECURITY SCREEN TO
SOUTH EAST SIDE ONLY
Keynote Legend
CODE DESCRIPTION
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
ST-03 PURLIN TO S.E. DETAILS
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
TOP OF EXISTING BRICK WORK BEYOND
REPLACE EXISTING CEILING
AND CORNICES. PAINT.
NEW COLORBOND
ROOF: KLIPLOCK TO
1.5° PITCH
NEW CFC EXTERNAL
CLADDING FIXED TO NEW
15MM TOPHATS
EXISTING WINDOW TO BE REFURBISHED
RF-01ST-03
ST-02
RF-02
ST-04
COLORBOND FLASHING
EXISTING CONCRETE SILL: REFER TO NOTE 1
EXISTING BRICK WALL
MODIFY EXISTING CLADDING TO
ALLOW THE NEW ROOF LINE IN
ORDER TO FIX NEW FLASHING.
COLORBOND FLASHING
STAFF TOILET
OUTRIGGER TO S.E. DETAILS
NOTE 1
CAREFULLY SCABLE, GRIND BACK
CONCRETE SILL TO EXPOSED
REINFORCEMENT. REMOVE WHERE IT IS
CORRODED , REINSTATE AND MAKE
GOOD.
REFER TO S.E. DETAILS
Ceiling
RL 2.400
ST-04
CG-02
MOISTURE
RESITANT
PLASTERBOARD
FIXED TO FURRING
CHANELS
ST-01
RF-05
CFC BOARD FIXED TO
TOPHATS, FIXED TO C
SECTIONS TO S.E.
DETAILS
EXISTING WINDOW
TO BE
REFURBISHED
FLASHING SURROUNDING
WINDOW EXTERNALLY
TO BE REPLACEDAND
PAINTED.
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
ALL DIMENSIONS ARE IN MILLIMETRES.
WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
LARGE SCALE DRAWINGS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS
GENERAL NOTES
THE CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT
OF ANY BUILDING WORK.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
ALL CONSULTANT DRAWINGS AND THE SPECIFICATION
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:39 AM
As indicated
0
OKA PROJECT No.18026 A5.02
DETAILS SHEET 2
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
SRW
A5.02
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 10A4.03Section 15 - Callout 11
Keynote Legend
CODE DESCRIPTION
CG-02 COVED CORNICE AS SPECIFIED
RF-01 COLORBOND KLIPLOCK WITH ANTICON 60 (R1.3)FOIL FACE INSULATION ON SAFETY MESH FIXED TONEW STRUCTURE TO S.E. DETAILS
RF-02 COLORBOND EAVES GUTTER TO MATCH EXISTINGIN SHAPE AND FIXING DETAILS
RF-05 COLORBOND FLASHING 0.48BMT (UNLESS NOTEDOTHERWISE)
ST-01 RHS TO S.E. DETAILS
ST-02 EA TO S.E. DETAILS
ST-03 PURLIN TO S.E. DETAILS
ST-04 C SECTION TO S.E. DETAILS
SCALE: 1 : 10A4.01Section B-B Detail 12
REV. DATE DESCRIPTION DWN CHECK
0 04.05.2018 TENDER SRW FI
NEW PAINT
CT-01 CT-01
CT-02
PT-03
SW-07
SW-05
CT-02
CT-01CL-01
SW-07SW-05
CT-02
Female
Female Toilets
Lobby
Duct
New Ceramic Tiles
WCWCWCWCWCWCWC
Ambulant
Toilet
New Hand
Washing
Trough
NEW COLUMNS TO S.E. DETAILS
COL COL
A701
1
2
4
A701 7
6
A701
4.1
CT-02
CT-02
5
3
SW-08
SW-07
SW-05 SW-06
SW-10
CT-01
CL-02
CL-01
CT-01
SW-03
SW-02
CT-01
CT-02
PT-02
PT-03
CT-01
Ground Floor
Ceiling
RL 2.400
CT-02
PT-03
SW-03
SW-02
1600 700
MIRROR
Female Toilets
Lobby
Female
TILED LEDGE
TILES TO TOP OF WALL
PAINTED BULKHEADMECH. DUCT
MI-01
CT-01
Ground Floor
Ceiling
RL 2.400
CT-02
PT-03CT-01
CT-02
PT-03
900
SW-08
42570
0
SW-10
SW-07
SW-06
AMBULANT TOILET TO COMPLY WITH AS 1428.1
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:41 AM
1 : 50
0
OKA PROJECT No.18026 A701
ROOM LAYOUTS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
CW
A701
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50A2.01Female Elev 11
SCALE: 1 : 50A2.01Female Elev 22
SCALE: 1 : 50A2.01Female Elev 44
Female Toilets Plan
SCALE: 1 : 50A2.01Female Elev 4.14.1
SCALE: 1 : 50A2.01FEMALE LOBBY ELEV 6.6
SCALE: 1 : 50A2.01FEMALE LOBBY ELEV 77
SCALE: 1 : 50A2.01Female Elev 55
SCALE: 1 : 50A2.01Female Elev 33
Keynote Legend
CODE DESCRIPTION
CL-01 LAMINEX TOILET PARTITION
CL-02 LAMINEX DOOR
CT-01 CERAMIC WALL TILE GLOSS NON RECTIFIED300X600
CT-02 CERAMIC FLOOR TILE & SKIRTING R10/P3 300X300
MI-01 BATHROOM MIRROR, FRAMED
PT-02 DOOR & TRIM PAINT - DULUX AQUANAMEL
PT-03 WALL PAINT - DULUX WASH & WEAR
SW-02 FEMALE WASH TROUGH 2200L X 390 X 150D
SW-03 TIMED FLOW BIB TAP
SW-05 CAROMA LUNA WALL FACED PAN
SW-06 CAROMA LUNA EASY HEIGHT PAN (AMBULANT)
SW-07 TOILET ROLL DISPENSER
SW-08 PAPER TOWEL & BIN
SW-10 AMBULANT GRAB RAILS
REV. DATE DESCRIPTION DWN CHECK
- 04.04.2018 ISSUED FOR COMMENTS SRW FI
0 04.05.2018 TENDER SRW FI
Male
Male Toilets
LobbyStore Room
Staff Toilet
Staff Toilets
Lobby
Duct
New Ceramic Tiles
New Urinal recessed into floor slabNew Hand
Washing
Trough
Ambulant
Toilet
WCWCWC
COLCOL
A702
3
4
1
2 A702
1.1
CT-02
CT-02CT-02
A702 4.1
870
SW-08
CT-01
SW-04
SW-05 SW-06
SW-07SW-10
CT-01
CT-02
100
CL-02
CL-01
PT-01
Ceiling
RL 2.400
CT-01SW-04
CT-02
SW-08
PT-01
CT-01
CT-02
SW-10
SW-06
PT-01
PT-02
PT-02
AMBULANT TOILET TO COMPLY WITH AS 1428.1
MI-01
CT-01CL-01
SW-07SW-04
SW-01
SW-03
CT-022660
taps
855
trou
gh75
0m
irror
900
1200
750
PT-01
700
800
SW-05
SW-07
SW-06
SW-10
CT-01
PT-01
PT-03
CT-02
CT-01PT-02
Stainless
Kick Panel 450
100
Department of
Building Management and Works
Finance
Government of Western Australia 150
REDUCTIONDRAWN DESIGNED
CHECKED
APPROVED
SCALE DATE
PRINCIPAL
SIGNATURE
DRAWING No.
THIS IS A CAD DRAWING.DO NOT AMEND MANUALLY.
OLDFIELD KNOTT
ARCHITECTS PTY LTD567 Hay Street DAGLISH WA 6008 | PO Box 849 SUBIACO WA 6904T: (08) 9381 6788 | F: (08) 9381 4619 | E: [email protected]
Institute of ArchitectsThe Royal Australian
DF PROJ No. DF FILE No.
C:\Revit Temp\WD_Toilet Block Refurbishment_swood.rvt 4/05/2018 10:38:44 AM
1 : 50
0
OKA PROJECT No.18026 A702
ROOM LAYOUTS
TOILET BLOCK UPGRADE, Dianella Heights PSBuilding Management and Works
Lot 7833, 9 Beaman Street , Dianella WA 6059
CW
A702
Designer
FI
Approver
March 2018
BMW 912318B45040
SCALE: 1 : 50
FLOOR PLAN
SCALE: 1 : 50A2.01MALE ELEV 3.3
SCALE: 1 : 50A2.01MALE ELEV 44
SCALE: 1 : 50A2.01MALE ELEV 22
SCALE: 1 : 50A2.01MALE ELEV 11
SCALE: 1 : 50A2.01Male Elev 1.11.1
SCALE: 1 : 50A2.01Male Lobby 4.14.1
Keynote Legend
CODE DESCRIPTION
CL-01 LAMINEX TOILET PARTITION
CL-02 LAMINEX DOOR
CT-01 CERAMIC WALL TILE GLOSS NON RECTIFIED300X600
CT-02 CERAMIC FLOOR TILE & SKIRTING R10/P3 300X300
MI-01 BATHROOM MIRROR, FRAMED
PT-01 CEILING PAINT - DULUX CEILING WHITE
PT-02 DOOR & TRIM PAINT - DULUX AQUANAMEL
PT-03 WALL PAINT - DULUX WASH & WEAR
SW-01 MALE WASH TROUGH 1350L X 390 X 150D
SW-03 TIMED FLOW BIB TAP
SW-04 BRITEX SANSTEP URINAL
SW-05 CAROMA LUNA WALL FACED PAN
SW-06 CAROMA LUNA EASY HEIGHT PAN (AMBULANT)
SW-07 TOILET ROLL DISPENSER
SW-08 PAPER TOWEL & BIN
SW-10 AMBULANT GRAB RAILS
REV. DATE DESCRIPTION DWN CHECK
- 04.04.2018 ISSUED FOR COMMENTS SRW FI
0 04.05.2018 TENDER SRW FI