SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator...

248
SimJunior Directions for Use EN FR DE ES IT BR NL JA ZH KO PL www.laerdal.com

Transcript of SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator...

Page 1: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

SimJuniorDirections for Use

EN

FR

DE

ES

IT

BR

NL

JA

ZH

KO

PL

www.laerdal.com

Page 2: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare
Page 3: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

1

Maintenance 12

โ€“ Maintenance after each Simulation Session 12 โ€“ Opening the Torso 13 โ€“ Replacing the Simulator Battery 13 โ€“ Charging the Simulator Battery 14 โ€“ Replacing the Chest Rise Bladder 14 โ€“ Replacing the Lung Bladder 14 โ€“ Replacing Simulator Skins 15 โ€“ Replacing the Right IV Arm 15 โ€“ Replacing the Right IO Leg 15

Troubleshooting 16

Introduction 2

โ€“ Regulatory Information 2 โ€“ General Simulator Care 3โ€“ SimJunior Overview Picture 5 โ€“ SimJunior Features 6

Simulator Setup 9

โ€“ Preparing for Simulations 9 โ€“ Preparing the IO Leg 9 โ€“ Administering IV Fluids 9 โ€“ Draining Excess IV Fluid 10 โ€“ Cleaning the IV Arm 10 โ€“ Installing Defibrillation Adapter Plates 10 โ€“ Connecting the Blood Pressure Cuff 10 โ€“ Calibrating the Blood Pressure Cuff 10 โ€“ Calibrating the Blood Pressure Cuff in SimPad 10โ€“ Changing the Pupils 11 โ€“ Using an External Compressor 11

Specifications 19

Simulation Software 8

โ€“ Instructor PC 8 โ€“ Software License 8 โ€“ Laerdal Simulation Home 8โ€“ LLEAP 8โ€“ Voice Conference Application 8โ€“ Patient Monitor 8โ€“ Session Viewer and SimView Server 8โ€“ Other Applications 8โ€“ SimDesigner 8โ€“ Help Files 8โ€“ Web Downloads 8

Spare Parts and Accessories 21

Table of Contents

Page 4: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

2

Li-ion

Introduction

Introducing SimJuniorโ„ข Simulator SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. SimJunior can be used for the education of individuals or teams of healthcare professionals from multiple medical disciplines.

The SimJunior Simulator comes completely assembled. There is no need to assemble parts of the Simulator.

For details on preparing SimJunior for simulation, go to โ€œSimulator Setupโ€ section.

SimJunior Help Directions for Use (DFU)

Step-by-step instructions and illustrations for using the SimJunior Simulator.

Original Manufacturerโ€™s User Manuals

All separate user manuals and labeling from original manufacturers should be followed. The SimJunior Directions for Use does not replace or supersede those from the original manufacturer.

SimJunior Quick Setup Guide

Step-by-step guide for setup of the SimJunior simulation system.

SimPad Directions for Use (DFU)

SimPad Directions for Use provides instructions for using the Link Box and the SimPad with SimJunior.

LLEAP Help Files (Laerdal Learning Application)

The LLEAP Help files are accessible from the Laerdal Simulation Home, see Laerdal Simulation Home.

Help topics include:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

Technical Assistance

For technical assistance, contact your local Laerdal Technical Service Center.

Web Downloads

Visit www.laerdal.com/downloads to download the latest Directions for Use and newer versions of the simulation software.

SimCenter Content SimCenter offers easy access to validated content from worldwide simulation experts so you can take advantage of their experience and get the most from every learning opportunity. You will find a wide range of scenarios that have been developed specifically for the SimJunior. Visit www.mysimcenter.com to learn how you can fully optimize your learning experience.

Regulatory Information

Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Caution Changes or modifications not expressly approved by the party responsible for compliance could void the userโ€™s authority to operate the equipment.

Li-ion batteries should be recycled.

The product is in compliance with the essential requirements of Council Directive 2004/108/EC on electromagnetic compatibility (EMC).

The product is in compliance with Council Directive 2011/65/EU on restriction of the use of certain hazardous substances (RoHS).

Dispose of in accordance with local requirements and regulations.

Page 5: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

3

Disclaimer Use of the SimJunior patient simulation system to train personnel should be undertaken under supervision of suitably trained technical or medical personnel with an understanding of educational principles as well as recognized medical protocols. As with all Simulators or other such training devices, there may be approximations, variations and inaccuracies in anatomical features and the physiological modeling. This being the case, Laerdal does not guarantee that all features are completely accurate.

Global Warranty See the Laerdal Global Warranty Booklet, or see www.laerdal.com.

Country of origin - SimJunior is made in USA.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Introduction

General Simulator Care Follow the instructions below to maintain optimum performance and longevity of the Simulator and its components.

General Care

To maintain Simulator skins, wash hands before use and place the Simulator on a clean surface. Laerdal recommends to:

โ€“ Use gloves during simulation scenarios. Avoid using colored plastic gloves, as they may cause discoloration of the Simulator skin.

โ€“ Do not use felt-tipped markers, ink pens, acetone, iodine, or other staining medications near the Simulator. Take care not to place the Simulator on newsprint or colored paper. Staining may be permanent.

โ€“ Clean Simulator skins with mild soap and water.

Do not attempt to perform the following techniques on this Simulator due to the inability to properly sanitize the airway:

โ€“ Mouth-to-mouth/mouth-to-mask ventilation

โ€“ Insertion of simulated vomit or fluids for suctioning

โ€“ If a training session involves the use of fluids in the IV arm, drain the arm immediately following the training session.

โ€“ Only use Laerdal Airway Lubricant, and apply sparingly

โ€“ Rinse, clean, and dry Simulator component modules

โ€“ Fold the torso skin back and powder the inside of the torso skin to decrease friction. Do not spill powder into Simulator chest cavity.

Environment In cold conditions, wait until the Simulator has reached room temperature before starting up.

To avoid overheating and reduce wear:

โ€“ When using in temperatures above 40ยฐC (104ยฐF), always allow the Simulator to cool down between training sessions.

โ€“ When using in a bed, Simulator should not be covered with heavy bedding which prevents heat transfer from the Simulator.

General Simulator Handling Take the following precautions to avoid personal injury or damage to the product:

โ€“ Introduce fluids into the Simulator only as directed in this document

โ€“ Lubricate the oral and nasal airways with the lubricant provided prior to inserting any instrument, tube, or airway device. Also lubricate instruments and tubes prior to use.

โ€“ Do not introduce humidified air into the system during ventilation

โ€“ Do not use the Simulator if the internal tubing and cabling is disconnected

โ€“ Never use the SimJunior Simulator outdoors in wet conditions, as this may pose a shock hazard or damage the Simulator.

โ€“ Using a defibrillator in temperatures over 35ยฐ C (95ยฐ F) may cause overheating

Warning: Do not use automated chest compression machines on the Simulator.

Caution Latex: This product contains Natural Rubber latex, which may cause allergic reactions when in contact with humans.

Defibrillation Hazards SimJunior allows for defibrillation.

A conventional defibrillator may be used on SimJunior. During defibrillation, the defibrillator and Simulator may present a shock hazard. All standard safety precautions must be taken when using a defibrillator on the Simulator.

โ€ข Read and follow all safety and operating instructions provided with your defibrillator and associated equipment.

โ€ข Follow defibrillation protocol by avoiding contact between the external paddles and any of the electrode sites while defibrillating. A load of up to 300 joules can be delivered.

โ€ข Failure to follow safety measures could result in injury or death.

For more information, consult your defibrillatorโ€™s original user manual.

Warnings:

โ€“ When performing defibrillation, use the defibrillator connectors or the zap plate mounted on the Simulatorโ€™s chest. Do not use the ECG connectors which are designed exclusively for ECG monitoring. Defibrillation on the ECG connectors will damage the internal electronics of the Simulator and may cause personal injury.

โ€“ Do not defibrillate the Simulator when it is turned OFF or if it is not functioning normally.

Page 6: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

4

Introduction

To prevent overheating during defibrillation, do not exceed a defibrillation sequence of 3 shocks in 45 seconds followed by 1 minute of CPR. After 30 minutes, cease all shocking for at least 15 minutes before starting a new sequence. Do not repeat this for more than a 4 hour period. Also, do not provide more than 2 x 300 defibrillator discharges per minute.

Warnings:

โ€“ The Simulator must not come into contact with electrically conductive surfaces or objects during defibrillation.

โ€“ Avoid use in all flammable environments. For example, high levels of pure oxygen should be avoided during defibrillation. Ensure good ventilation if concentrated oxygen is used near the Simulator.

โ€“ The Simulator torso must always be kept dry.

โ€“ Allow the Simulator to acclimate before defibrillating. Sudden changes in temperature may result in condensation collecting on electronic components, which could pose a shock hazard.

โ€“ To prevent torso skin electrode pitting, do not apply conductive gel or conductive defibrillation pads intended for patient use.

โ€“ Pressing down too hard on the defibrillation connectors during defibrillation may also cause arcing and pitting.

โ€“ Do not defibrillate the Simulator if the torso skin is not in place.

Mechanical or Electrical Hazards Do not use the SimJunior Simulator if:

โ€“ Limbs are not attached to the torso

โ€“ Skins are torn or not properly fastened

โ€“ Internal or external cables, tubes or connectors are damaged

โ€“ There is fluid leakage in or on the Simulator

โ€“ There are unusual sounds indicating air leakage or mechanical damage

โ€“ There are signs of electrical malfunction, such as an unresponsive Simulator or unusual smell or smoke

Warning:

โ€“ Avoid pinch hazards - Do not use the Simulator without the external skins

Battery Use and Maintenance

โ€“ Always use batteries approved to power the SimJunior, Link Box, and SimPad.

โ€“ Ensure that the batteries are properly installed. Inserting and connecting batteries incorrectly could cause a short circuit.

Warnings:

โ€“ Dispose of batteries according to local regulations.

โ€“ The external battery charger is for indoor use only.

โ€“ The Simulator battery should only be charged in temperatures ranging from 0 ยฐC - 40ยฐC (32 ยฐF - 104 ยฐF)

โ€“ Do not mistreat, disassemble, or attempt to repair the battery. Do not use the batteries if they are visibly damaged, malfunctioning, or appear to be leaking.

โ€“ Take extreme care to avoid direct contact with electrical, hot or smoking parts. In case of a leaking battery, disconnect and remove the battery when it is judged safe to do so.

โ€“ Exposure to fluids pose an explosion hazard.

โ€“ On every 30th charge cycle, drain the battery completely before recharging. To drain the battery, run the Simulator on battery power until automatic shutdown.

โ€“ Only replace with a Laerdal SimJunior battery.

Storage and Transportation

โ€“ Never store fully charged batteries for longer than a month.

โ€“ The Simulator battery can be transported in the Simulator during air freight.

โ€“ When transporting spare batteries, contact the airline or freight company for the latest transport regulations.

Warning:

โ€“ The SimJunior Simulator and accessories are heavy when combined in the carrying case. Always ensure that SimJunior is firmly secured during transportation and storage to prevent personal injury or damage to the product.

Page 7: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

5

IO Leg

IO Leg Fill Port

SimJunior Simulator

Right Arm ECG Connector

Sternum Defib Plate

IV Arm

Right Leg ECG Connector

Power Cable

External Air Connection

Simulator Cable (60 pin)

Introduction

Left Arm ECG Connector

Blood Pressure Arm

Apex Defib Plate

Left Leg ECG Connector

Page 8: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

6

Introduction

SimJunior Simulator SimJunior facilitates interactive training of life-saving skills and responds to clinical intervention by instructor control and/or pre-programmed scenarios for effective practice of diagnosis and treatment of a patient.

With spontaneous breathing, airway control, voice, sounds, ECG, and other clinical features, SimJunior is a fully functional pediatric simulator. SimJunior allows observation and recognition of most vital signs, which enables the instructor to assess the studentโ€™s skills based on a realistic clinical situation.

SimJunior Features

โ€“ Realistic airway for simulation of difficult airway management, oral, and nasal intubation

โ€“ Observable breathing

โ€“ Cardiac features, including defibrillation and cardioversion

โ€“ Eyes with interchangeable pupils (normal, dilated, or constricted)

โ€“ Convulsions to simulate seizures

โ€“ Chest compressions

โ€“ Vascular access

โ€“ Normal and abnormal heart, breath, and bowel sounds

โ€“ Automatic Simulation Control based on pre-programmed and validated patient scenarios

Simulations can run autonomously using scenarios on the SimPad or with LLEAP (PC). The development of the patientโ€™s condition is pre-programed and automatically responds according to the participant interventions.

Overall Dimensions

Length / Width (Simulator only): 45 in x 9.84 in (120 cm x 42.5 cm) Weight (Simulator only): 25 lbs (11.36 kg)

SimJunior Clothing

SimJunior comes with custom designed clothing with Velcro openings for easy removal. Washing instructions are found on the clothing label.

โ€“ Shirt

โ€“ Shorts

โ€“ Boxer Shorts

General Clinical Features Airway Features

The airway is anatomically correct to the trachea. The airway can be manipulated by:

โ€“ Head tilt/chin lift

โ€“ Jaw thrust with articulated jaw

โ€“ Cricoid pressure and manipulation

โ€“ Suctioning (oral and nasopharyngeal)

The Simulator may be ventilated by normal and emergency methods:

โ€“ Bag-mask ventilation

โ€“ Orotracheal intubation

โ€“ Nasotracheal intubation

Prior to using airway devices, lubricate with Laerdal Airway Lubricant.

The following equipment or methods are suitable to secure the Simulatorโ€™s airway:

โ€“ Laryngeal mask airways (size #2.5)

โ€“ Endotracheal tube intubation (size ID 4.5 cuffed, 5.5 uncuffed)

Use of a malleable stylet is recommended. Make sure it does not extend beyond the ET tube.

The following Simulator conditions indicate incorrect tube placement:

โ€“ Right main stem intubation โ€“ unilateral chest rise

โ€“ Stomach distention

โ€“ Lack of chest sounds (see Breathing section)

Simulator features may be configured to present various airway scenarios:

โ€“ Tongue edema - normal, medium, maximum levels

โ€“ Lungs open or closed

Breathing Features

SimJunior can simulate spontaneous breathing with visible chest rise and fall and variable breathing rates. The breathing is generated by an enclosed air compressor in the Simulatorโ€™s right thigh.

โ€“ Bilateral chest rise and fall with spontaneous breathing

โ€“ Unilateral chest rise and fall with right mainstem intubation during ventilations

โ€“ Unilateral and bilateral lung sounds

โ€“ Normal and abnormal breath sounds

โ€“ Variable respiration rate (0-60 breaths per minute)

โ€“ Anterior auscultation sites (4)

The left lung and right lung can be closed independently or together to create a partial or complete airway obstruction. The SimJunior Simulator can also be used with assisted ventilations.

Note: Lungs are not intended for use with PEEP-valves.

Page 9: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

7

Introduction

Circulatory Features

Cardiac:

โ€“ Extensive ECG library, pulses from 0-200

โ€“ Heart sounds - anterior location (1)

โ€“ ECG rhythm monitoring (4-connector, 3-lead ECG)

โ€“ 12-lead ECG display (Using LLEAP only)

โ€“ Pacing

โ€“ Defibrillation and cardioversion using live defibrillators

Defibrillation:

โ€“ The number of shocks required for automatic conversion are set in each simulation Patient Case

Defibrillation Studs:

3-Lead ECG Studs:

Blood Pressure and Pulses:

โ€“ BP measured manually by auscultation of Korotkoff sounds

โ€“ Bilateral carotid pulse

โ€“ Central pulses can be set to Normal, Weak, Absent

โ€“ Radial/Brachial pulses can be set to Normal, Weak, Absent

โ€“ Carotid, brachial and radial pulses synchronized with ECG

โ€“ Pulse strength variable with BP

โ€“ Pulse palpation is detected and logged

CPR Features

โ€“ Compliant with 2010 Guidelines

โ€“ Compressions generate palpable pulses, blood pressure wave form, and ECG artifacts

โ€“ Realistic compression depth and resistance

โ€“ Detection of depth and rate of compressions

Vascular Features

IV Access:

IV access is possible on the right arm and hand. The IV arm can be set up for IV insertion, infusion, and bolus into:

โ€“ Peripheral veins of the forearm

โ€“ Antecubital fossa and dorsum of the hand

For use of an optional catheter, see your local Laerdal representative.

Intraosseous Access (IO):

Access for IO infusion is possible:

โ€“ Tibial Tuberosity (right)

โ€“ Medial Malleolus

Note: SimJunior does not have intra-muscular (IM) injection sites. Do not attempt to perform IM injections.

Sound Settings for SimJunior SimJunior supports multiple sites for auscultation and recognition of heart, lung, and bowel sounds. SimJunior also allows you to set vocal sounds.

For more information on setting sounds for SimJunior, see SimPad Directions for Use or LLEAP Help Files.

Page 10: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

8

Simulation Software

Instructor PC

The Instructor PC uses LLEAP software to manage simulation sessions. LLEAP, as well as other useful simulation related applications, is accessible from Laerdal Simulation Home.

Software License The Instructor PC is shipped from Laerdal Medical with a pre-activated license for LLEAP installed.

Changes or updates of the computer hardware (e.g. new hard drive or mother board) may render the license invalid. Please contact your local Laerdal support for assistance for re-activating the license.

Laerdal Simulation HomeLaerdal Simulation Home is an application from where LLEAP and other Laerdal programs related to patient simulation can be found and started. The help files can also be opened from here. Laerdal Simulation Home is located in the Laerdal Medical folder under the Windows start menu (Windows 7).

Software used in a simulation session can be divided in the following main applications:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server or Session Viewer

In addition SimDesigner and other applications are used for designing or preparing a simulation.

LLEAPThe Leardal Learning Application (LLEAP) is the instructorโ€™s application from where the simulation session is run, controlled, and monitored. LLEAP can be operated in Automatic or Manual mode. Automatic mode is used for pre-programmed scenarios while Manual mode allows the instructor full manual control over the simulation session. Running simulations in Manual Mode generally requires some medical expertise to create clinically sound simulations.

Voice Conference Application (VCA)The VCA software is needed to transmit all vocal sounds used during simulation. It allows the instructor to communicate through the simulator during the session. VCA can also be used to communicate with other instructors on a network, and create separate channels that only members can talk and listen to.

Patient MonitorThe Patient Monitor application emulates a typical hospital patient monitor. It is the learnerโ€™s console and can be set up and controlled by the instructor, as well as by the learner, through on-screen touch menus.

Session Viewer and SimView ServerSession Viewer and SimView Server are applications that record video and patient monitor screen captures during simulation, in addition to providing an interface to debrief your session. After a session is ended, log files generated in LLEAP are transferred and merged with the video files in Session Viewer or SimView Server for the debrief.

Session Viewer typically runs locally on the same computer used for LLEAP, SimView Server runs on a dedicated server in the local network. During the first start-up of LLEAP you are prompted to select a debriefing system available on your computer or local network. This can be changed later.

Other ApplicationsThere are also other programs that are used in conjunction with the simulation sessions, for example License Manager for handling program licenses and Simulator Firmware & Network Fixer for updating the firmware of the simulators or troubleshooting network problems.

SimDesignerSimDesigner is an application for configuring your own pre-programmed scenarios. It can also be used to analyze and print out a graphical representation of a scenario.

SimDesigner must be installed to allow conversion of legacy instructor application files to LLEAP compatible file formats.

Help Files

For more information on the LLEAP software and other applications, see the Help files:

1. Click Windows <Start> <All programs>.

2. Select <Laerdal Simulation Home>.

3. Select <Help>.

Web DownloadsVisit www.laerdal.com/downloads to download the latest User Guide and Software.

Page 11: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

9

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Simulator Setup

Preparing for Simulations After the SimJunior Simulator is prepared and all applicable interactive devices (SimPad or Instructor PC and Patient Monitor) are configured and made ready for use, final preparations may need to be performed before SimJunior is ready to run simulations.

Final simulation preparations include the following activities:

โ€ข Preparing the IO leg

โ€ข Administering IV Fluids

โ€ข Draining Excess IV Fluid

โ€ข Cleaning the IV Arm

โ€ข Connecting Defibrillation Adapter Plates

โ€ข Connecting the Blood Pressure Cuff

โ€ข Changing the Pupils

โ€ข Connecting an External Compressor

โ€ข Changing Settings for the Internal Compressor

Preparing the IO Leg The Simulatorโ€™s right leg is designed for practicing intraosseous infusion skills. Anatomy of the right leg includes knee, tibia, tibial tuberosity site, and medial malleolus site. The right leg comes with IV tubing and one IV bag for use as a reservoir during infusion.

Additional equipment needed:

โ€ข IV bag and administration set

โ€ข Simulated blood concentrate

โ€ข 35cc syringe and 16-gauge intraosseous needle

To fill the IO Leg and prepare it for use:

1. Raise the leg vertically.

2. Open the plug at the heel.

3. With a syringe, fill the bone with approximately 240 to 250 cc of simulated blood.

4. Attach tubing connected to an IV reservoir bag. (Use roller clamp to open or close the line as needed in order to relieve pressure build-up.)

5. Close off tubing that runs into the reservoir bag so that simulated blood will remain in the bone for aspiration.

6. When the reservoir bag is filled, discontinue infusion and replace with empty bag.

Before storing the Simulator:

โ€“ Detach the IV line and reservoir from the foot

โ€“ Allow all fluid to drain

โ€“ Store leg unplugged to allow it to air dry

Note: Do not use saline solution. It may cause deterioration of the leg. Use distilled or de-ionized water to avoid buildup of minerals.

Administering IV Fluids The right IV Arm supports training for IV drug administration, IV insertion, infusion, and bolus into peripheral veins of forearm, antecubital fossa, and dorsum of the hand.

Use 20 to 22 gauge needle for IV simulation. To prevent clogging of the IV system, use only distilled or de-ionized water to simulate IV drugs.

Page 12: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

10

Simulator Setup

Draining Excess IV Fluid The IV fluid system is an open system. IV fluids are drained as they are administered.

Before each session:

1. Attach the IV overflow tube (in the Simulatorโ€™s right arm) to an overflow container (such as an IV bag).

2. Allow excess fluid to drain into a container during the simulation.

Cleaning the IV Arm Clean the IV arm after each session or day of use by flushing the IV Arm with 60% isopropanol or 70% ethanol.

Installing Defibrillation Adapter Plates The Simulator torso is fitted with two stud connectors for defibrillator cables. Before attempting defibrillation, you must unscrew and remove the defibrillator stud covers.

Two defibrillation adapter plates are packaged with the Simulator. The defibrillator adapter plates must be fitted in place before using a live defibrillator with defibrillation paddles or adhesive pads. Screw the adapter plates firmly into place.

During Defibrillation A conventional defibrillator (not included) may be used on the SimJunior. During live defibrillation, the defibrillator and Simulator may present a shock hazard. All standard safety precautions must be taken when using the defibrillator on the Simulator.

Caution: The Simulator must not be in contact with electrically conductive surfaces or objects during defibrillation.

Warnings:

โ€“ Defibrillation must be performed on the defibrillator connectors only.

โ€“ Do not press too hard over the defibrillation adapters as this may cause arcing and pitting.

โ€“ Do not defibrillate the Simulator without the torso skin in place.

Connecting the Blood Pressure Cuff

The Simulator is delivered with a customized Blood Pressure Cuff. Connect the tube to the white BP connector on back of the Link Box before use.

Note: The speaker for the Simulatorโ€™s blood pressure is located in the left antecubital fossa, circled below. The radial and brachial pulses are located in the rectangular areas.

Calibrating the Blood Pressure Cuff

1. Select <Tools> from the menu

2. Select <Simulator Setup> from the Tools-menu

3. Select <Calibrate Blood Pressure> from the sub-menu

4. Follow the on screen wizard instructions to perform the calibration

Page 13: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

11

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Simulator Setup

Changing the Pupils

SimJunior is delivered with normal pupils installed in the eyes. A separate kit containing plastic pupil inserts (constricted and dilated) comes with SimJunior.

To change the pupils:

1. Carefully open the eyelids wide, taking care not to tear the Simulator face skin.

2. Using the suction cup tool provided in the kit or with the edge of your fingernail, carefully remove the pupil from the eye.

3. Replace the pupil with the desired insert, using the suction cup tool or by gently pressing in place.

Using an External Compressor The external compressor connects to the clear tube found in the cable bundle exiting the right side of the Simulator. When using an external compressor you can turn off the internal compressor from SimPad or LLEAP.

For more information on external compressors and regulator panels compatible with SimJunior, contact your local Laerdal representative.

Turning on or off the internal compressor in SimPad

1. Start <Manual Mode>, select a theme and start the session.

2. Select <Miscellaneous> from the bottom menu.

3. Select <Compressor> from the sub-menu.

4. Make the desired changes in the dialog and click OK.

Turning on or off the internal compressor in LLEAP

1. Select <Tools> from the menu.

2. Select <Simulator Setup> from the Tools-menu.

3. Select <Internal compressor> from the sub-menu.

4. Make the desired changes in the dialog and click OK.

Page 14: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

12

Note: For information on and spare parts, see section: Spare Parts and Accessories.

Before Storage or Shipping

โ€“ Flush the IV arm with 60% Isopropanol alcohol or 70% ethanol. Open the drain valve on the bottom of the Simulatorโ€™s right foot.

Maintenance

Maintenance after each Simulation Session The following preventive measures are required to ensure longevity of the SimJunior Simulator.

โ€“ Power off the SimPad, Link Box and PCs

โ€“ Charge batteries if necessary

โ€“ Flush the IV-arm system and drain the IO leg (leave the plug in the bottom of the IO leg open)

โ€“ After each session where the IV-arm has been used, flush the IV arm with 60% Isopropanol alcohol or 70% ethanol

โ€“ Wipe the skin with a moist cloth

โ€“ Remove wet clothes or linens

โ€“ Remove tape residue with a moist cloth or rubbing alcohol

โ€“ Based on the use of the Simulator, replace modules that are consumed or damaged

โ€“ Replace cables or connectors showing visible damage

โ€“ Servicing should be performed by qualified personnel at regular intervals

Always perform a service:

โ€“ If liquids have been spilled in or on the Simulator

โ€“ After use in dusty environments

Page 15: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

13

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Maintenance

Opening the Torso

Open the Simulator torso to perform procedures such as:

โ€“ Attaching or replacing limbs

โ€“ Replacing the Simulator Battery

โ€“ Replacing the Chest Rise Bladder and Lung Bladder

โ€“ Replacing the Torso Skin

โ€“ For general inspection

Warning: Open the torso from left to right, gently unhook the skin. Do not pull hard to lift the Torso Skin, this could damage the chest cables.

1. Unhook Torso Skin holders on left side of the torso and each shoulder.

Replacing the Simulator Battery

1. Open the Simulator torso.

2. Fold the Torso Skin over to the right side.

3. Disconnect the Defibrillation connector cable.

4. The Defibrillation connector cable must be disconnected at the right side of the Simulator below the chest form.

Note: DO NOT disconnect the tubes and cables connecting the stomach foam to the Simulator.

5. Replace the Torso Skin by performing steps 1- 4 in reverse.

2. Slide the battery out of the battery strap.

3. Pull the battery power connection up from inside the Simulator. Unhook the battery power connection.

4. Lift the battery out of the Simulator.

5. Replace the charged battery or install a new Laerdal approved SimJunior battery.

6. Connect the battery to the Simulator.

7. Replace the Torso Skin.

Page 16: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

14

Maintenance

Charging the Simulator Battery

The Simulator battery charges itself as it is operated. If necessary, the Simulator battery can be charged using an optional external power adapter.

1. Power down the Simulator via the Link Box.

2. Remove the Simulator battery from the Simulator.

3. Connect an approved external battery charger (with a power cord that meets local specifications) to the bottom of the Simulator battery. Connect the battery chargerโ€™s power cord into a wall outlet.

4. When the battery has finished charging, replace the battery in the Simulator.

Replacing the Chest Rise Bladder The Chest Rise Bladder is located in the lower end of the chest plate, centered under the lungs.

1. Open the Torso Skin to expose the chest plate. See Opening the Torso.

2. Disconnect the clear tubing from the Lung Bladder and remove the Lung Bladder. For more details, see Replacing the Lung Bladder

3. Disconnect the clear tubing from the Chest Rise Bladder.

4. Discard the old bladder.

5. Insert new bladder.

6. Re-connect the tubing to the new bladder.

7. Close the torso and replace the Torso Skin.

Replacing the Lung Bladder If leaking occurs, the Lung Bladder (in the chest cavity) should be replaced.

1. Open the Torso Skin.

2. Disconnect the clear tubing from under each side of the lung bladder. Refer to step 2 illustration in Replacing the Chest Rise Bladder.

3. Disconnect the Lung Bladder clip from the top center.

4. Gently pull the top center portion of the Lung Bladder up from its socket.

5. Reverse the process to install the new Lung Bladder.

Page 17: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

15

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Replacing Simulator Skins The Simulator skins may need to be replaced if they are torn, perforated, or stained.

Torso Skin:

To replace the Simulator torso skin, see Opening the Torso.

Arm Skin:

To replace the Simulator Arm Skin:

1. Remove the old Simulator Arm Skin by working it down over the arm and hand or *cut the skin.

Warning: *Do not puncture or cut the mandrel arm.

To attach the new arm:

Maintenance

Replacing the Right IV Arm

1. Open the torso, see Opening the Torso.

2. Remove old arm by unscrewing the bolt holding the arm to the Simulatorโ€™s shoulder.

3. Ensure that the shoulder screw is loose enough to allow the arm axle to slide out easily.

4. Discard the old arm according to specified guidelines.

1. Ensure that the shoulder screw is loose enough to allow the arm axle to slide easily into place.

2. Connect the arm to the corresponding connection points in the torso.

3. Carefully push the arm axle into the shoulder bracket, so that the axle is flush with the inside of the bracket.

4. Tighten the shoulder screw with an Allen wrench.

Replacing the Right IO Leg To detach the right lower leg:

1. Ensure that any fluid in the leg has been drained.

2. Remove old IO Leg by unscrewing the bolt holding it to the thigh.

3. Slide the IO lower Leg out from the thigh.

4. Discard the old IO Leg according to specified guidelines.

Reverse the above process to attach the new IO Leg.

2. Discard old skin.

3. Lubricate inside of new Arm Skin with mild liquid detergent mixed with water.

4. Lubricate (or lather) mandrel with a mix of mild liquid soap and water.

5. Slide Simulator hand into skin.

6. Work skin over fingers (as with a glove).

7. Work skin up, over the arm mandrel.

Page 18: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

16

Troubleshooting

System Setup

Problem

โ€ข Lost data or total system failure (General System failure).

Possible Solution

โ€ข Should system shutdown occur or all data is lost or corrupted; please contact your local Laerdal Service Center.

LLEAPโ€ข See Software Help Files > LLEAP > Troubleshooting Guide

(Help is accessible from Laerdal Simulation Home)

Laerdal Patient Monitorโ€ข See Software Help Files > Laerdal Patient Monitor>

Troubleshooting Guide. (Help is accessible from Laerdal Simulation Home)

Debriefing and video recordingโ€ข See section for Troubleshooting in SimView Help (accessible from

a link at the bottom of the screen in SimView) or Troubleshoot-ing Guide from SessionViewer Help (accessible from Laerdal Simulation Home)

Simulator

Problem

โ€ข Unpredictable behavior.

Possible Solutions

โ€ข Simulator malfunctions may be caused by loose cables, tubes or connectors. Open the torso and check if any items appear to have become disconnected or are leaking. See section: Simulator Setup - Opening the Torso.

โ€ข In case of fluid leakage, power off the Simulator and contact Laerdal Technical Service.

Airway Contamination

Problem

โ€ข Simulator airways have become contaminated from mouth-to-mouth rescue breathing.

Possible Solution

โ€ข Clean the outside of the Simulator with Simulator wipes. Clean the inside of the oral cavity with Simulator wipes. Change the lung bladder; see section: Maintenance - Replacing Lung Bladder.

Chest Movement

Problem

โ€ข No chest rise on Simulator.

Possible Solutions

โ€ข Check that power to Simulator is ON.

โ€ข In SimPad or LLEAP, check that โ€“ awRR is not set to zero

โ€“ Chest Rise is not set to OFF

โ€“ ECG is set to a perfusing rhythm.

โ€“ Airway complications like maximum air resistance or laryngospasm are not set.

โ€“ Verify that the Integrated Compressor is enabled in LLEAP. See section: Turning the Internal Compressor Off.

โ€ข Check that any external compressed air source is switched off and that the air tube is disconnected from the Simulator.

โ€ข The internal compressor may be overheated. Wait approximately 20 minutes for it to cool down.

โ€ข Chest rise is set to bilateral (for example if ET-tube is inserted too far into the bronchia).

โ€ข Chest rise bladder is leaking or tubing to chest rise bladder is twisted kinked or disconnected. Replace chest rise bladder if it is leaking, see Maintenance: Replacing the Chest Rise Bladder.

โ€ข Check air tubing for leakage; check that all connections are intact. Replacing tubing section if leaking.

โ€ข Shallow chest movements and the internal compressor runs continuously. The internal compressor may be worn. Contact Laerdal Technical Service.

Lungs

Problem

โ€ข Lungs not functioning properly

Possible Solutions

โ€ข Open the torso and chest plate. Check that the lungs are free to expand and are not restricted by any cables.

โ€ข Check that the Lung Bladder is properly connected, and that the tubes are not twisted.

โ€ข Check that the Lung Bladder is in a horizontal position and inserted correctly.

Page 19: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

17

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Troubleshooting

โ€ข Check for flaws or tearing in the lung bladder.

โ€ข Check that there are no obstructions inside the Simulator airways which may block air flow.

โ€ข If there is no change when adjusting lung compliance, contact Laerdal Technical Service.

โ€ข If there is no change in lung resistance, contact Laerdal Technical Service.

Mechanical Noise during AuscultationIn LLEAP click <Auscultation focus>.

Pulses (Radial and Brachial)

Problem

โ€ข Cannot feel pulses

Possible Solutions

โ€ข Skin may be too tight over pulse units โ€“ re-adjust skin and reboot.

โ€ข Ensure blood pressure is set to at least 60 systolic.

โ€ข Ensure compressor is ON.

Note: If the radial pulse is set below 60, peripheral pulses may disappear.

Simulator Shutdown

Problem

โ€ข The Simulator is unresponsive.

Solution

1. Power off the Link Box.

2. Turn the SimPad off, or if you are using LLEAP turn the instructor PC off.

3. Restart everything.

If the Simulator is still unresponsive, contact your Laerdal representative.

Page 20: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

18

Notes

Page 21: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

19

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Specifications

Overall Dimensions Length / Width (Simulator only): 45 in x 9.84 in (120 cm x 42.5 cm) Weight (Simulator only): 25 lbs (11.36 kg)

Simulator Power External power: Input voltage 9VDC, 1.5A Internal battery: 7.4V, 4.4Ah, Lithium-Ion

Only use approved SimJunior external power supply and batteries.

Air Pressure Internal air tank: Max 6 psi External air connection: Max 16 psi

Temperature Limits Operating temperatures: +4 ยบC to 40 ยบC (39 ยบF to 104 ยบF) Storage temperatures: -15 ยบC to 50 ยบC (5 ยบF to 122 ยบF)

Environment - Simulator only Relative humidity: 20% -90% (non-condensing) DO NOT use outdoors in wet conditions. Not tested with salt spray.

RF Communication Operation range: 10 m (30 ft) max.

Material Chart for Simulator Clothes: Cotton, Nylon Skins and airways: PVC External hard plastics: PVC, ABS Inner plastics: Silicone, TPU, PVC, Nitrile ABS, POM, Nylon + GF Epoxy-Polyurethane Metal components: Aluminum, Brass, Steel

Minimum Computer Requirements

โ€ข Intel i-core generation 3 or newer

โ€ข Score over 3000 PassMark - CPU Mark

โ€ข 4 GB RAM

โ€ข 120GB hard disk space

โ€ข 1366x768 or better

โ€ข Headset w/microphone

โ€ข USB ports โ€“ 2

Minimum Software Requirements

โ€ข Windows 7 or Windows 8

โ€ข 100% DPI

Cleaning Fluids To clean the Simulator use one of the following:

โ€“ 60% Isopropanol alcohol

โ€“ 70% Ethanol

โ€“ Mild solution of liquid soap and water

IV Fluids Only use distilled or deionized water to simulate IV and IO fluids.

Page 22: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

20

Notes

Page 23: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

21

Sim

ulat

ion

Soft

war

e

Sim

ulat

or S

etup

M

aint

enan

ce

Spar

e Pa

rts

Spec

ifica

tions

In

trod

uctio

n

Trou

bles

hoot

ing

Spare Parts and Accessories

Spare Parts and Accessories

For latest version of Spare Parts and Accessories, visit www.laerdal.com

Page 24: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

22

Notes

Page 25: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

23

Entretien 34

โ€“ Entretien aprรจs chaque session de simulation 34 โ€“ Ouverture du tronc 35 โ€“ Remplacement de la batterie du simulateur 35 โ€“ Chargement de la batterie du simulateur 36 โ€“ Remplacement du coussinet pour soulรจvement

de la poitrine 36 โ€“ Remplacement de la poche pulmonaire 36 โ€“ Remplacement des surfaces cutanรฉes du simulateur 37 โ€“ Remplacement du bras droit (bras de perfusion) 37 โ€“ Remplacement de la jambe droite (jambe IO) 37

Guide de dรฉpannage 38

Introduction 24

โ€“ Informations rรฉglementaires 24 โ€“ Entretien du simulateur : gรฉnรฉralitรฉs 25โ€“ Photographie dโ€™ensemble de SimJunior 27 โ€“ Caractรฉristiques du SimJunior 28

Configuration du simulateur 31

โ€“ Prรฉparation des simulations 31 โ€“ Prรฉparation de la jambe IO 31 โ€“ Administration de liquides intraveineux 31 โ€“ Drainage de lโ€™excรฉdent de liquide intraveineux 32 โ€“ Nettoyage du bras de perfusion 32 โ€“ Installation des plaques adaptateur pour

dรฉfibrillation rรฉelle 32 โ€“ Raccordement du brassard ร  tension artรฉrielle 32 โ€“ Calibrage du brassard ร  tension artรฉrielle dans LLEAP 32 โ€“ Calibrage du brassard ร  tension artรฉrielle dans SimPad 32โ€“ Remplacement des pupilles 33 โ€“ Utilisation dโ€™un compresseur externe 33

Caractรฉristiques techniques 41

Logiciel de simulation 30

โ€“ PC du formateur 30 โ€“ Licence du logiciel 30 โ€“ Laerdal Simulation Home 30โ€“ LLEAP 30โ€“ Voice Conference Application 30โ€“ Patient Monitor 30โ€“ Session Viewer et SimView Server 30โ€“ Autres applications 30โ€“ SimDesigner 30โ€“ Fichiers dโ€™aide 30โ€“ Tรฉlรฉchargements ร  partir dโ€™Internet 30

Accessoires et piรจces dรฉtachรฉes 43

Table des matiรจres FR

Page 26: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

24

Introduction

Prรฉsentation du simulateur SimJuniorโ„ข SimJunior est un simulateur patient pรฉdiatrique rรฉaliste de taille rรฉelle conรงu par Laerdal en collaboration avec lโ€™Acadรฉmie amรฉricaine de pรฉdiatrie. SimJunior peut servir ร  la formation de personnes ou dโ€™รฉquipes de professionnels de santรฉ de diverses spรฉcialitรฉs.

Le simulateur SimJunior est livrรฉ entiรจrement assemblรฉ. Aucun montage nโ€™est donc nรฉcessaire.

Pour plus dโ€™informations sur la prรฉparation du SimJunior pour une simulation, reportez-vous ร  la section ยซ Configuration du simulateur ยป.

Aide relative au simulateur SimJunior Mode dโ€™emploi

Ce manuel illustrรฉ dรฉtaille les instructions dโ€™utilisation du simulateur SimJunior.

Manuels utilisateur du fabricant dโ€™origine

Vous devez respecter les instructions de tous les manuels utilisateur et รฉtiquetages des fabricants dโ€™origine. Le mode dโ€™emploi du SimJunior ne remplace ni nโ€™annule en aucun cas les instructions fournies par le fabricant dโ€™origine.

Guide de configuration rapide du SimJunior

Ce guide dรฉtaille les instructions dโ€™installation du systรจme de simulation SimJunior.

Mode dโ€™emploi SimPad

Le mode dโ€™emploi SimPad fournit des instructions relatives ร  lโ€™utilisation de la Link Box et du systรจme SimPad avec le simulateur SimJunior.

Fichiers dโ€™aide de LLEAP (Laerdal Learning Application)

Les fichiers dโ€™aide de LLEAP sont accessibles ร  partir de Laerdal Simulation Home ; voir Laerdal Simulation Home.

Lโ€™aide inclut notamment les rubriques suivantes :

โ€“ LLEAP

โ€“ Session Viewer (visualiseur de session)

โ€“ Application confรฉrence

โ€“ SimDesigner

โ€“ ร‰diteur de tendances

Assistance technique

Pour toute assistance technique, contactez le centre de service technique Laerdal local.

Tรฉlรฉchargements ร  partir dโ€™Internet

Visitez le site www.laerdal.com/downloads pour tรฉlรฉcharger le dernier mode dโ€™emploi et les versions les plus rรฉcentes du logiciel de simulation.

Contenu de SimCenter SimCenter offre un accรจs aisรฉ au contenu validรฉ par des experts internationaux en simulation, pour que vous puissiez tirer profit de leur expรฉrience et tirer le meilleur parti de toute opportunitรฉ dโ€™apprentissage. Vous trouverez un grand nombre de scรฉnarios mis au point spรฉcifiquement pour le simulateur SimJunior. Visitez le site www.mysimcenter.com pour dรฉcouvrir comment exploiter pleinement votre formation.

Informations rรฉglementaires

Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Mise en garde Tout changement ou toute modification non expressรฉment autorisรฉ par la partie responsable de la conformitรฉ pourrait annuler lโ€™autorisation de faire fonctionner lโ€™รฉquipement.

Li-ion

Les batteries au lithium-ion doivent รชtre recyclรฉes.

Ce produit est conforme aux exigences essentielles de la directive 2004/108/CE du Conseil relative ร  la compatibilitรฉ รฉlectromagnรฉtique (CEM).

Ce produit est conforme ร  la directive 2011/65/UE du Conseil relative ร  la limitation de lโ€™utilisation de certaines substances dangereuses.

Mettez ce produit au rebut conformรฉment aux prescriptions et rรฉglementations locales.

Page 27: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

25

Introduction

Clause de non-responsabilitรฉ La formation de personnel ร  lโ€™aide de SimJunior doit sโ€™effectuer sous la responsabilitรฉ dโ€™un intervenant mรฉdical ou technique dรปment formรฉ et ayant connaissance des principes pรฉdagogiques et des protocoles mรฉdicaux reconnus. ร€ lโ€™instar de tout autre simulateur ou dispositif de formation comparable, la modรฉlisation physiologique et les caractรฉristiques anatomiques de cet appareil peuvent prรฉsenter certaines approximations, variations ou inexactitudes. Laerdal ne saurait donc garantir lโ€™exactitude totale de toutes les fonctionnalitรฉs.

Garantie mondiale Consultez la brochure de garantie mondiale de Laerdal ou rendez-vous sur notre site Web www.laerdal.com.

Pays dโ€™origine : SimJunior est fabriquรฉ aux ร‰tats-Unis.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, ร‰tats-Unis

Entretien du simulateur : gรฉnรฉralitรฉs Suivez les instructions ci-dessous pour favoriser le fonctionnement optimal et prolonger la durรฉe de vie du simulateur et de ses composants.

Entretien gรฉnรฉral

Avant de procรฉder ร  lโ€™entretien des peaux du simulateur, lavez-vous les mains, puis placez le simulateur sur une surface propre. Laerdal prรฉconise les recommandations suivantes :

โ€“ Utilisez des gants pendant toute la durรฉe des scรฉnarios de simulation. Nโ€™utilisez pas de gants en plastique colorรฉ, car ils entraรฎneraient une altรฉration de la couleur de la peau du simulateur.

โ€“ Nโ€™utilisez pas de marqueurs, de stylo-plume, dโ€™acรฉtone, dโ€™iode ou tout autre produit mรฉdicamenteux colorant ร  proximitรฉ du simulateur. Veillez ร  ne pas placer le simulateur sur du papier journal ou du papier colorรฉ. Les taches pourraient รชtre irrรฉversibles.

โ€“ Nettoyez les peaux du simulateur au savon doux et ร  lโ€™eau.

Vous ne devez pas appliquer les techniques suivantes ร  ce simulateur en raison de lโ€™impossibilitรฉ de dรฉsinfecter convenablement les voies respiratoires :

โ€“ Ventilation bouche-ร -bouche ou bouche-ร -masque.

โ€“ Introduction de liquides ou de vomi (simulation) ร  des fins dโ€™aspiration.

โ€“ Si une session de formation implique lโ€™injection de liquides dans le bras de perfusion, purgez celui-ci immรฉdiatement aprรจs la session.

โ€“ Utilisez uniquement le lubrifiant pour voies respiratoires Laerdal et appliquez-le avec modรฉration.

โ€“ Rincez, nettoyez et sรฉchez les modules composant le simulateur.

โ€“ Rabattez la peau du torse et appliquez du talc ร  lโ€™intรฉrieur de celle-ci pour rรฉduire la friction. Ne rรฉpandez pas de talc dans la cavitรฉ thoracique du simulateur.

Environnement

Par temps froid, patientez jusquโ€™ร  ce que le simulateur atteigne la tempรฉrature ambiante avant de le mettre en marche.Pour รฉviter toute surchauffe et prรฉvenir lโ€™usure du simulateur, procรฉdez comme suit :

โ€“ Sโ€™il est utilisรฉ ร  des tempรฉratures supรฉrieures ร  40 ยฐC, laissez systรฉmatiquement le simulateur refroidir entre deux sessions de formation.

โ€“ Sโ€™il est utilisรฉ dans un lit, ne couvrez pas le simulateur avec trop de couvertures, au risque dโ€™empรชcher le transfert de chaleur.

Manipulation du simulateur : gรฉnรฉralitรฉs Pour prรฉvenir tout dommage corporel ou matรฉriel, observez les mesures de prรฉcaution suivantes :

โ€“ Lors de lโ€™introduction de liquides dans le simulateur, respectez systรฉmatiquement les instructions fournies dans ce document.

โ€“ Lubrifiez les voies respiratoires orales et nasales ร  lโ€™aide du lubrifiant fourni avant toute insertion dโ€™un quelconque instrument, tube ou dispositif pour voies respiratoires. Lubrifiez รฉgalement les instruments et les tubes avant utilisation.

โ€“ Nโ€™introduisez pas dโ€™air humidifiรฉ dans le systรจme pendant la ventilation.

โ€“ Nโ€™utilisez pas le simulateur si la tubulure ou le cรขblage interne est dรฉbranchรฉ.

โ€“ Nโ€™utilisez en aucun cas le simulateur SimJunior en extรฉrieur par temps humide, sous peine de provoquer une dรฉcharge รฉlectrique ou dโ€™endommager le simulateur.

โ€“ Lโ€™utilisation dโ€™un dรฉfibrillateur ร  des tempรฉratures supรฉrieures ร  35 ยฐC peut provoquer une surchauffe

Avertissement : nโ€™utilisez pas dโ€™appareils de compression thoracique automatisรฉs sur le simulateur.

Attention โ€” Prรฉsence de latex : ce produit contient du latex de caoutchouc naturel, susceptible de provoquer chez certaines personnes des rรฉactions allergiques en cas de contact.

Risques associรฉs ร  la dรฉfibrillation Le simulateur SimJunior permet dโ€™avoir recours ร  la dรฉfibrillation.

Le simulateur SimJunior est compatible avec un dรฉfibrillateur traditionnel. Pendant la dรฉfibrillation, le dรฉfibrillateur comme le simulateur peuvent prรฉsenter un risque de choc รฉlectrique. Toutes les mesures de prรฉcaution habituelles doivent donc รชtre prises lors de lโ€™utilisation dโ€™un dรฉfibrillateur sur le simulateur.

โ€ข Lisez attentivement et suivez toutes les consignes de sรฉcuritรฉ et le mode dโ€™emploi livrรฉs avec votre dรฉfibrillateur et tout autre รฉquipement connexe.

โ€ข Suivez le protocole de dรฉfibrillation en รฉvitant tout contact entre les palettes externes et la zone de pose des รฉlectrodes lors de la dรฉfibrillation. Vous pourriez dans le cas contraire recevoir une dรฉcharge รฉlectrique pouvant atteindre 300 joules.

โ€ข Le non-respect des mesures de sรฉcuritรฉ peut entraรฎner des blessures, voire la mort.

Pour plus dโ€™informations, consultez la notice dโ€™utilisation accompagnant le dรฉfibrillateur.

Page 28: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

26

Introduction

Pour รฉviter toute surchauffe lors de la dรฉfibrillation, nโ€™effectuez pas plus dโ€™une sรฉquence de 3 dรฉcharges en 45 secondes, suivie dโ€™une minute de RCP. Aprรจs 30 minutes, respectez une pause dโ€™au moins 15 minutes (aucune dรฉcharge) avant dโ€™entamer une nouvelle sรฉquence. Ne recommencez pas cette opรฉration sur une pรฉriode de plus de 4 heures. De plus, veillez ร  ne pas dรฉlivrer plus de 2 dรฉcharges de dรฉfibrillateur ร  300 joules par minute.

Avertissements :

โ€“ Pendant la dรฉfibrillation, le simulateur ne doit pas entrer en contact avec des surfaces ou des objets conducteurs.

โ€“ ร‰vitez toute utilisation dans des environnements inflammables. ร‰vitez par exemple lโ€™utilisation de niveaux รฉlevรฉs dโ€™oxygรจne pur pendant la dรฉfibrillation. Si de lโ€™oxygรจne concentrรฉ est utilisรฉ ร  proximitรฉ du simulateur, assurez-vous que la piรจce est bien aรฉrรฉe.

โ€“ Le tronc du simulateur doit toujours rester sec.

โ€“ Laissez le simulateur sโ€™acclimater avant de procรฉder ร  la dรฉfibrillation. Un รฉcart de tempรฉrature soudain peut entraรฎner la formation de condensation sur les composants รฉlectroniques, ce qui pourrait provoquer une รฉlectrocution.

โ€“ Pour รฉviter l'altรฉration de la peau du torse, nโ€™appliquez pas de gel conducteur ni dโ€™รฉlectrodes conductrices destinรฉs aux patients.

โ€“ Lors de la dรฉfibrillation, nโ€™appuyez pas trop fort sur les connecteurs de dรฉfibrillation, au risque dโ€™entraรฎner une altรฉration et la formation dโ€™un arc รฉlectrique.

โ€“ Ne procรฉdez ร  aucune dรฉfibrillation tant que la peau du torse du simulateur nโ€™est pas en place.

Risques mรฉcaniques ou รฉlectriques Nโ€™utilisez pas le simulateur SimJunior dans les cas suivants :

โ€“ Si les membres ne sont pas rattachรฉs au tronc

โ€“ Si les peaux sont dรฉchirรฉes ou ne sont pas attachรฉes correctement

โ€“ Si les cรขbles, tubes ou connecteurs internes ou externes sont endommagรฉs

โ€“ Si une fuite de liquide est prรฉsente dans ou sur le simulateur

โ€“ Si des sons inhabituels signalent une fuite dโ€™air ou un dommage mรฉcanique

โ€“ Sโ€™il existe des signes de dysfonctionnement รฉlectrique, tels quโ€™une absence de rรฉponse du simulateur ou une odeur ou fumรฉe inhabituelle

Avertissement :

โ€“ ร‰vitez tout risque de pincement โ€“ Nโ€™utilisez pas le simulateur si les surfaces cutanรฉes ne sont pas fixรฉes.

Utilisation et entretien de la batterie

โ€“ Utilisez toujours une batterie approuvรฉe pour lโ€™alimentation du simulateur SimJunior, de la Link Box et du systรจme SimPad.

โ€“ Assurez-vous que la batterie et les piles sont correctement installรฉes. Une insertion et une connexion incorrectes peuvent provoquer un court-circuit.

Avertissements :

โ€“ Mettez les batteries au rebut conformรฉment aux rรฉglementations locales.

โ€“ Le chargeur de batterie externe ne doit รชtre utilisรฉ quโ€™ร  lโ€™intรฉrieur.

โ€“ La batterie du simulateur ne doit รชtre chargรฉe quโ€™ร  des tempรฉratures comprises entre 0 et 40 ยฐC.

โ€“ Ne malmenez pas, ne dรฉmontez pas et ne tentez pas de rรฉparer les batteries. Nโ€™utilisez en aucun cas une batterie ou une pile visiblement endommagรฉe, dรฉfectueuse ou semblant fuir.

โ€“ Prenez toutes les prรฉcautions nรฉcessaires pour รฉviter tout contact direct avec les composants รฉlectriques, chauds ou รฉmettant de la fumรฉe. En cas de fuite, dรฉbranchez et retirez la batterie lorsque vous estimez que cela est sans danger.

โ€“ Lโ€™exposition aux liquides prรฉsente un risque dโ€™explosion.

โ€“ Tous les 30 cycles de charge, videz entiรจrement la batterie avant de la recharger. Pour ce faire, faites fonctionner le simulateur sur batterie jusquโ€™ร  ce quโ€™il sโ€™arrรชte automatiquement.

โ€“ Remplacez la batterie uniquement par une batterie SimJunior de Laerdal.

Stockage et transport

โ€“ Ne stockez jamais des batteries entiรจrement chargรฉes pendant plus dโ€™un mois.

โ€“ Pendant un transport aรฉrien, la batterie peut rester dans le simulateur.

โ€“ Pour le transport des batteries de rechange, renseignez-vous auprรจs de la compagnie aรฉrienne ou du transporteur au sujet des derniรจres rรฉglementations รฉmises en matiรจre de transport.

Avertissement :

โ€“ Une fois le simulateur SimJunior et ses accessoires placรฉs dans la housse de transport, le poids de lโ€™ensemble est consรฉquent. Pour รฉviter tout dommage corporel ou matรฉriel durant le transport et le stockage, veillez toujours ร  ce que le simulateur SimJunior soit solidement arrimรฉ.

Avertissements :

โ€“ Lors de la dรฉfibrillation, utilisez les connecteurs du dรฉfibrillateur ou la plaque installรฉe sur la poitrine du simulateur. Nโ€™utilisez pas les connecteurs dโ€™ECG ; ceux-ci sont destinรฉs exclusivement au monitoring du rythme cardiaque. Une dรฉfibrillation pratiquรฉe sur les connecteurs dโ€™ECG endommagerait les composants รฉlectroniques internes du simulateur et pourrait entraรฎner des blessures.

โ€“ Nโ€™effectuez pas de dรฉfibrillation sur le simulateur lorsque celui-ci est dรฉsactivรฉ ou sโ€™il ne fonctionne pas correctement.

Page 29: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

27

Jambe IO

Orifice de remplissage de la jambe IO

Simulateur SimJunior

Connecteur dโ€™ECG du bras droit

Plaque de dรฉfib. sternum

Bras de perfusion

Connecteur dโ€™ECG de la jambe droite

Cรขble dโ€™alimentation

Raccord dโ€™air externe

Cรขble du simulateur (60 broches)

Introduction

Connecteur dโ€™ECG du bras gauche

Bras de tension artรฉrielle

Plaque de dรฉfib. apex

Connecteur dโ€™ECG de la jambe gauche

Page 30: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

28

Introduction

Simulateur SimJunior Le simulateur SimJunior permet une formation interactive aux premiers secours ainsi quโ€™un entraรฎnement efficace au diagnostic et au traitement dโ€™un patient, grรขce ร  sa capacitรฉ ร  rรฉpondre ร  une intervention clinique, au contrรดle du formateur et ร  des scรฉnarios prรฉ-programmรฉs.

Respiration spontanรฉe, contrรดle des voies respiratoires, voix, effets sonores, ECG et autres caractรฉristiques cliniques font du SimJunior un simulateur pรฉdiatrique entiรจrement fonctionnel. Le SimJunior permet lโ€™observation et la dรฉtection de la plupart des signes vitaux, ce qui permet au formateur dโ€™รฉvaluer les compรฉtences des รฉtudiants dans le cadre dโ€™une situation clinique rรฉaliste.

Caractรฉristiques du SimJunior

โ€“ Voies respiratoires rรฉalistes pour simuler une gestion difficile des voies respiratoires et lโ€™intubation orale et nasale

โ€“ Respiration observable

โ€“ Fonctions cardiaques, notamment dรฉfibrillation et cardioversion

โ€“ Yeux avec pupilles interchangeables (normales, dilatรฉes ou contractรฉes)

โ€“ Convulsions

โ€“ Compressions thoraciques

โ€“ Accรจs vasculaire

โ€“ Bruits intestinaux, respiratoires et cardiaques normaux et anormaux

โ€“ Contrรดle de simulation automatique basรฉ sur des scรฉnarios patients prรฉ-programmรฉs et validรฉs

Les simulations peuvent รชtre exรฉcutรฉes de maniรจre autonome ร  lโ€™aide de scรฉnarios sur le systรจme SimPad ou LLEAP (PC). Lโ€™รฉvolution de lโ€™รฉtat du patient est prรฉ-programmรฉe et varie automatiquement en fonction des interventions du participant.

Dimensions globales

Longueur/largeur (simulateur seul) : 120 cm x 42,5 cm Poids (simulateur seul) : 11,36 kg

Vรชtements du SimJunior

SimJunior est livrรฉ avec des vรชtements conรงus sur mesure et munis de bandes auto-agrippantes permettant de les enlever plus facilement. Les instructions de lavage figurent sur lโ€™รฉtiquette des vรชtements.

โ€“ Chemise

โ€“ Short

โ€“ Caleรงon

Caractรฉristiques cliniques gรฉnรฉrales Fonctions des voies respiratoires

Lโ€™anatomie des voies respiratoires du simulateur est correcte jusquโ€™ร  la trachรฉe. Les voies respiratoires peuvent รชtre libรฉrรฉes de diverses maniรจres :

โ€“ Inclinaison de la tรชte/bascule du menton

โ€“ Subluxation mandibulaire grรขce ร  la mรขchoire articulรฉe

โ€“ Manipulation et pression cricoรฏdienne

โ€“ Aspiration (orale et nasopharyngรฉe).

Le simulateur peut รชtre ventilรฉ au moyen de mรฉthodes normales et dโ€™urgence :

โ€“ Ventilation au ballon-masque

โ€“ Intubation orotrachรฉale

โ€“ Intubation nasotrachรฉale

Avant dโ€™introduire un quelconque dispositif dans les voies respiratoires du simulateur, appliquez du lubrifiant pour voies respiratoires Laerdal.

Les mรฉthodes ou รฉquipements suivants permettent de protรฉger les voies respiratoires du simulateur :

โ€“ Masque laryngรฉ (taille : 2,5)

โ€“ Sonde dโ€™intubation endotrachรฉale (taille du DI : 4,5 avec ballonnet, 5,5 sans ballonnet)

Lโ€™utilisation dโ€™un mandrin flexible est recommandรฉe. Assurez-vous quโ€™il ne dรฉpasse pas la longueur du tube trachรฉal.

Les conditions suivantes indiquent un mauvais positionnement de la sonde dans le simulateur :

โ€“ Intubation de la bronche souche droite : la poitrine se soulรจve de faรงon unilatรฉrale

โ€“ Estomac distendu

โ€“ Absence de bruits thoraciques (voir la section ยซ Fonctions respiratoires ยป).

Les fonctions du simulateur peuvent รชtre configurรฉes pour reproduire divers scรฉnarios de voies respiratoires :

โ€“ ล’dรจme de la langue, niveaux normal, moyen et maximal

โ€“ Poumons ouverts ou fermรฉs

Fonctions respiratoires

Le SimJunior peut simuler une respiration spontanรฉe par la compression et le soulรจvement visibles de la poitrine et des frรฉquences respiratoires variables. La respiration est simulรฉe par un compresseur dโ€™air intรฉgrรฉ dans la cuisse droite du simulateur.

โ€“ Mouvement bilatรฉral de la poitrine avec respiration spontanรฉe

โ€“ Mouvement unilatรฉral de la poitrine avec intubation bronchique droite pendant les ventilations

โ€“ Sons pulmonaires unilatรฉraux et bilatรฉraux

โ€“ Bruits respiratoires normaux et anormaux

โ€“ Frรฉquence respiratoire variable (0 ร  60 souffles par minute)

โ€“ Sites dโ€™auscultation antรฉrieure (4)

Les poumons gauche et droit peuvent รชtre fermรฉs sรฉparรฉment ou en mรชme temps afin de crรฉer une obstruction partielle ou complรจte des voies respiratoires. Le simulateur SimJunior peut รฉgalement รชtre ventilรฉ mรฉcaniquement.

Remarque : les poumons ne doivent pas รชtre utilisรฉs avec des valves de PEP.

Page 31: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

29

Introduction

Fonctions cardio-vasculaires

Cardiaque :

โ€“ Bibliothรจque ECG bien remplie, pouls de 0 ร  200

โ€“ Sons cardiaques โ€“ zone antรฉrieure (1)

โ€“ Monitoring du rythme cardiaque (4 connecteurs, ECG 3 dรฉrivations)

โ€“ ร‰cran ECG 12 dรฉrivations (LLEAP uniquement)

โ€“ Stimulation

โ€“ Dรฉfibrillation et cardioversion au moyen de vrais dรฉfibrillateurs

Dรฉfibrillation :

โ€“ Le nombre de dรฉcharges nรฉcessaires ร  la conversion automatique est dรฉfini dans chaque simulation de cas patient.

Goujons de dรฉfibrillation :

Plots dโ€™ECG trois dรฉrivations :

Pouls et tension artรฉrielle :

โ€“ TA mesurรฉe manuellement par lโ€™auscultation des bruits de Korotkoff

โ€“ Pouls carotidien bilatรฉral

โ€“ Pouls central programmable (normal, faible ou absent)

โ€“ Pouls radial/brachial programmable (normal, faible ou absent)

โ€“ Pouls carotidien, brachial et radial synchronisรฉs avec lโ€™ECG

โ€“ Intensitรฉ variable du pouls en fonction de la tension artรฉrielle

โ€“ Dรฉtection et enregistrement des pulsations par palpation

Fonctions RCP

โ€“ Conformes aux directives de 2010.

โ€“ Les compressions gรฉnรจrent des pouls palpables, une courbe de tension artรฉrielle et des artefacts sur le tracรฉ dโ€™ECG.

โ€“ Profondeur de compression et rรฉsistance ร  la compression rรฉalistes.

โ€“ Dรฉtection de la profondeur et de la frรฉquence des compressions.

Fonctions vasculaires

Accรจs intraveineux :

Il est possible dโ€™effectuer une perfusion IV au niveau de la main et du bras droits. Le bras de perfusion peut รชtre configurรฉ de maniรจre ร  permettre une injection/perfusion IV et lโ€™administration dโ€™un bolus par voie IV aux points dโ€™injection suivants :

โ€“ Veines pรฉriphรฉriques de lโ€™avant-bras

โ€“ Fosse antรฉcubitale et dos de la main

Accรจs intra-osseux (IO) :

Il est possible dโ€™effectuer une perfusion IO aux points dโ€™injection suivants :

โ€“ Tubรฉrositรฉ tibiale (tibia droit)

โ€“ Mallรฉole mรฉdiale

Remarque : SimJunior ne comporte pas de points dโ€™injection intramusculaire (IM). Nโ€™essayez pas dโ€™effectuer des injections IM.

Rรฉglages sonores du SimJunior SimJunior prend en charge de nombreux sites dโ€™auscultation et de dรฉtection des bruits cardiaques, pulmonaires et intestinaux, et offre la possibilitรฉ de configurer des sons vocaux.

Pour plus dโ€™informations sur le rรฉglage des sons de SimJunior, consultez le mode dโ€™emploi de SimPad ou les fichiers dโ€™aide de LLEAP.

Page 32: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

30

Logiciel de simulation

PC du formateur

Le PC du formateur utilise le logiciel LLEAP pour la gestion des sessions de simulation. LLEAP, tout comme les autres applications utiles ร  la simulation, est accessible depuis Laerdal Simulation Home.

Licence du logiciel Le PC du formateur fourni par Laerdal Medical est livrรฉ avec une licence prรฉ-activรฉe installรฉe pour LLEAP.

Les modifications ou les mises ร  jour du matรฉriel informatique (par ex., nouveau disque dur ou nouvelle carte mรจre) peuvent invalider la licence. Contactez le service technique local de Laerdal, qui vous aidera ร  rรฉactiver la licence.

Laerdal Simulation HomeLaerdal Simulation Home est une application depuis laquelle il est possible de dรฉmarrer LLEAP et dโ€™autres programmes Laerdal associรฉs ร  la simulation patient. Vous pouvez รฉgalement ouvrir les fichiers dโ€™aide depuis cet emplacement. Laerdal Simulation Home se trouve dans le dossier Laerdal Medical, accessible depuis le menu Dรฉmarrer de Windows (Windows 7).

Le logiciel utilisรฉ dans une session de simulation se compose des principales applications suivantes :

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server ou Session Viewer (visualiseur de session)

Par ailleurs, SimDesigner et dโ€™autres applications vous serviront ร  concevoir ou ร  prรฉparer une simulation.

LLEAPLaerdal Learning Application (LLEAP) est lโ€™application dรฉdiรฉe au formateur, qui lui permet dโ€™exรฉcuter, de commander et de surveiller la session de simulation. LLEAP peut utiliser le mode Manuel et le mode Automatique. Le mode Automatique est utilisรฉ pour les scรฉnarios prรฉ-programmรฉs tandis que le mode Manuel permet au formateur de contrรดler manuellement toute la session de simulation. Lโ€™exรฉcution de simulations en mode Manuel exige gรฉnรฉralement une certaine expertise mรฉdicale afin de crรฉer des simulations judicieuses sur le plan clinique.

Voice Conference Application (VCA)Le logiciel VCA est nรฉcessaire pour pouvoir transmettre tous les sons vocaux utilisรฉs pendant la simulation. Il permet au formateur de communiquer par le biais du simulateur pendant la session. Le logiciel VCA peut aussi รชtre utilisรฉ pour communiquer avec dโ€™autres formateurs sur un rรฉseau et pour crรฉer des canaux sรฉparรฉs sur lesquels seuls les membres peuvent communiquer.

Patient MonitorLโ€™application du Patient Monitor permet dโ€™รฉmuler un moniteur patient hospitalier classique. Cโ€™est la console de lโ€™apprenant, qui peut รชtre configurรฉe et commandรฉe par le formateur comme par lโ€™apprenant par le biais de menus tactiles ร  lโ€™รฉcran.

Session Viewer et SimView ServerSession Viewer et SimView Server sont des applications qui enregistrent de la vidรฉo et des captures dโ€™รฉcran du moniteur patient lors dโ€™une simulation, en plus de fournir une interface pour le dรฉbriefing dโ€™une session. ร€ la fin dโ€™une session, les fichiers journaux gรฉnรฉrรฉs dans LLEAP sont transfรฉrรฉs et fusionnรฉs avec les fichiers vidรฉo dans Session Viewer ou dans SimView Server pour le dรฉbriefing.

Gรฉnรฉralement, Session Viewer est exรฉcutรฉ sur le mรชme ordinateur que LLEAP et SimView Server, sur un serveur dรฉdiรฉ sur le rรฉseau local. Au premier lancement de LLEAP, vous รชtes invitรฉ ร  sรฉlectionner un systรจme de dรฉbriefing disponible sur votre ordinateur ou sur un rรฉseau local. Celui-ci peut รชtre modifiรฉ ultรฉrieurement.

Autres applicationsDโ€™autres programmes sont รฉgalement utilisรฉs en combinaison avec les sessions de simulation, par exemple le License Manager pour gรฉrer les licences de programme et Simulator Firmware & Network Fixer pour mettre ร  jour le microprogramme des simulateurs et dรฉpanner les problรจmes rรฉseau.

SimDesignerSimDesigner est une application permettant de configurer vos propres scรฉnarios prรฉ-programmรฉs. Lโ€™application peut รฉgalement รชtre utilisรฉe pour analyser et imprimer la reprรฉsentation graphique dโ€™un scรฉnario.

SimDesigner doit รชtre installรฉ pour permettre la conversion de fichiers dโ€™une application dรฉdiรฉe au formateur hรฉritรฉe en formats de fichiers compatibles LLEAP.

Fichiers dโ€™aide

Pour plus dโ€™informations sur le logiciel LLEAP et les autres applications, consultez les fichiers dโ€™aide :

1. Sous Windows, cliquez sur <Dรฉmarrer> <Tous les programmes>.

2. Sรฉlectionnez <Laerdal Simulation Home>.

3. Sรฉlectionnez <Aide>.

Tรฉlรฉchargements ร  partir dโ€™InternetConsultez www.laerdal.com/downloads pour tรฉlรฉcharger le dernier mode dโ€™emploi et le logiciel.

Page 33: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

31

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Configuration du simulateur

Prรฉparation des simulations Une fois le simulateur SimJunior installรฉ et toutes les unitรฉs interactives (SimPad ou PC du formateur et moniteur patient) correctement raccordรฉes et configurรฉes, vous devrez peut-รชtre effectuer les derniers prรฉparatifs avant de pouvoir exรฉcuter des simulations ร  lโ€™aide du systรจme SimJunior.

Par exemple, vous devrez :

โ€ข Prรฉparer la jambe IO

โ€ข Administrer des liquides intraveineux

โ€ข Drainer lโ€™excรฉdent de liquide intraveineux

โ€ข Nettoyer le bras de perfusion

โ€ข Raccorder les plaques adaptateur pour dรฉfibrillation rรฉelle

โ€ข Raccorder le brassard ร  tension artรฉrielle

โ€ข Remplacer les pupilles

โ€ข Raccorder un compresseur externe

โ€ข Modifier les paramรจtres du compresseur interne

Prรฉparation de la jambe IO La jambe droite du simulateur est spรฉcialement conรงue pour lโ€™exercice de perfusion intra-osseuse. Elle comprend notamment un genou, un tibia, une zone de tubรฉrositรฉ tibiale et une zone de mallรฉole mรฉdiale. Cette jambe est livrรฉe avec une tubulure IV et une poche IV servant de rรฉservoir pendant la perfusion.

Matรฉriel supplรฉmentaire nรฉcessaire :

โ€ข Poche IV et ensemble de perfusion

โ€ข Faux-sang concentrรฉ simulรฉ

โ€ข Seringue 35 cc et aiguille intra-osseuse de calibre 16

Pour remplir et prรฉparer la jambe IO, procรฉdez comme suit :

1. Levez la jambe ร  la verticale.

2. Ouvrez le capuchon situรฉ sur le talon.

3. ร€ lโ€™aide dโ€™une seringue, remplissez lโ€™os avec environ 240 ร  250 cc de sang simulรฉ.

4. Raccordez la tubulure reliรฉe ร  la poche de rรฉservoir IV (utilisez un clamp ร  roulette pour ouvrir ou fermer la tubulure, afin de libรฉrer la pression accumulรฉe).

5. Fermez la tubulure conduisant ร  la poche de rรฉservoir afin que le sang simulรฉ reste dans lโ€™os et puisse รชtre aspirรฉ.

6. Cessez la perfusion lorsque la poche de rรฉservoir est remplie, puis remplacez celle-ci par une poche vide.

Avant de ranger le simulateur :

โ€“ Dรฉconnectez la ligne IV et la poche de rรฉservoir du pied.

โ€“ Purgez tout le liquide de la jambe.

โ€“ Rangez la jambe sans mettre le capuchon afin quโ€™elle puisse sรฉcher ร  lโ€™air libre.

Remarque : nโ€™utilisez pas de sรฉrum physiologique. Cela pourrait endommager la jambe. Utilisez de lโ€™eau distillรฉe ou dรฉsionisรฉe pour รฉviter lโ€™accumulation de minรฉraux.

Administration de liquides intraveineux Le bras de perfusion droit est spรฉcialement conรงu pour la formation ร  lโ€™administration de mรฉdicaments injectables, ร  lโ€™injection et ร  la perfusion par voie intraveineuse, ainsi quโ€™ร  lโ€™administration de bolus via les veines pรฉriphรฉriques de lโ€™avant-bras, de la fosse antรฉcubitale et du dos de la main.

Lors dโ€™une simulation IV, utilisez une aiguille de calibre 20 ร  22. Pour รฉviter lโ€™obstruction du systรจme IV, utilisez uniquement de lโ€™eau distillรฉe ou dรฉsionisรฉe pour simuler les mรฉdicaments injectables.

Page 34: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

32

Configuration du simulateur

Drainage de lโ€™excรฉdent de liquide intraveineux Le systรจme de liquide intraveineux est un systรจme ouvert. Les liquides intraveineux sont donc รฉliminรฉs au fur et ร  mesure quโ€™ils sont administrรฉs.

Avant chaque session :

1. Raccordez le tube de trop-plein IV (situรฉ dans le bras droit du simulateur) ร  un rรฉcipient collecteur (par exemple, une poche IV).

2. Laissez lโ€™excรฉdent de liquide sโ€™รฉcouler dans un rรฉcipient collecteur pendant la simulation.

Nettoyage du bras de perfusion Nettoyez le bras de perfusion aprรจs chaque session ou ร  la fin de la journรฉe en rinรงant abondamment avec de lโ€™isopropanol ร  60 % ou de lโ€™รฉthanol ร  70 %.

Installation des plaques adaptateur pour dรฉfibrillation rรฉelle Le tronc du simulateur est dotรฉ de deux connecteurs ร  vis pour les cรขbles du dรฉfibrillateur. Avant toute tentative de dรฉfibrillation, dรฉvissez et retirez les goujons du dรฉfibrillateur.

Le simulateur est fourni avec deux plaques adaptateur pour dรฉfibrillation rรฉelle. Celles-ci doivent รชtre en place pour que vous puissiez utiliser un dรฉfibrillateur dynamique dotรฉ de palettes. Veillez ร  les visser solidement.

Pendant la dรฉfibrillation Le simulateur SimJunior est compatible avec un dรฉfibrillateur conventionnel (non fourni). Pendant la dรฉfibrillation rรฉelle, le dรฉfibrillateur comme le simulateur peuvent prรฉsenter un risque de choc รฉlectrique. Toutes les mesures de prรฉcaution habituelles doivent donc รชtre prises lors de lโ€™utilisation dโ€™un dรฉfibrillateur sur le simulateur.

Attention : pendant la dรฉfibrillation, le simulateur ne doit pas entrer en contact avec des surfaces ou des objets conducteurs.

Avertissements :

โ€“ La dรฉfibrillation doit รชtre effectuรฉe sur les connecteurs de dรฉfibrillation uniquement.

โ€“ Ne procรฉdez ร  aucune dรฉfibrillation tant que la peau du torse du simulateur nโ€™est pas en place.

Raccordement du brassard ร  tension artรฉrielle

Le simulateur est livrรฉ avec un brassard ร  tension artรฉrielle conรงu sur mesure. Avant toute utilisation, connectez le tube au connecteur de tension artรฉrielle blanc situรฉ ร  lโ€™arriรจre de la Link Box.

Remarque : le haut-parleur de la tension artรฉrielle du simulateur se situe dans la fosse antรฉcubitale gauche, identifiรฉe par un cercle dans lโ€™illustration ci-dessous. Les rectangles signalent quant ร  eux la position des pouls radial et brachial.

Calibrage du brassard ร  tension artรฉrielle dans LLEAP

1. Sรฉlectionnez <Outils> dans le menu.

2. Sรฉlectionnez <Configuration du simulateur> dans le menu Outils.

3. Sรฉlectionnez <Calibrer la tension artรฉrielle> dans le sous-menu.

4. Pour procรฉder au calibrage, suivez les instructions fournies par lโ€™assistant virtuel.

Calibrage du brassard ร  tension artรฉrielle dans SimPad

1. Sรฉlectionnez <Calibrage> dans le menu.

2. Sรฉlectionnez <Calibrer la tension artรฉrielle> dans le menu dรฉroulant.

3. Pour procรฉder au calibrage, suivez les instructions fournies par lโ€™assistant virtuel.

Page 35: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

33

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Configuration du simulateur

Remplacement des pupilles

Des pupilles normales sont installรฉes en usine sur le simulateur SimJunior. Un kit distinct contenant des pupilles de rechange en plastique (contractรฉes et dilatรฉes) est fourni avec le SimJunior.

Pour remplacer les pupilles, procรฉdez comme suit :

1. Ouvrez dรฉlicatement les paupiรจres du simulateur en veillant ร  ne pas dรฉchirer la peau du visage.

2. Retirez avec soin la pupille de lโ€™ล“il ร  lโ€™aide de la ventouse fournie avec le kit ou avec lโ€™extrรฉmitรฉ de votre ongle.

3. Installez ensuite la pupille de votre choix ร  lโ€™aide de la ventouse ou en appuyant doucement.

Utilisation dโ€™un compresseur externe Le compresseur externe se raccorde au tube transparent situรฉ dans le faisceau de cรขbles sortant du cรดtรฉ droit du simulateur. Lorsque vous utilisez un compresseur externe, vous pouvez รฉteindre le compresseur interne depuis SimPad ou LLEAP.

Pour plus dโ€™informations sur les compresseurs externes et les panneaux de rรฉgulation compatibles avec le simulateur SimJunior, contactez votre reprรฉsentant Laerdal local.

Mise en marche ou arrรชt du compresseur interne de SimPad

1. Dรฉmarrez en <Mode Manuel>, sรฉlectionnez un thรจme et commencez la session.

2. Sรฉlectionnez <Divers> dans le menu infรฉrieur.

3. Sรฉlectionnez <Compresseur> dans le sous-menu.

4. Apportez les modifications souhaitรฉes dans la boรฎte de dialogue, puis cliquez sur OK.

Mise en marche ou arrรชt du compresseur interne de LLEAP

1. Sรฉlectionnez <Outils> dans le menu.

2. Sรฉlectionnez <Configuration du simulateur> dans le menu Outils.

3. Sรฉlectionnez <Compresseur interne> dans le sous-menu.

4. Apportez les modifications souhaitรฉes dans la boรฎte de dialogue, puis cliquez sur OK.

Page 36: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

34

Remarque : pour plus dโ€™informations sur les piรจces dรฉtachรฉes, reportez-vous ร  la section ยซ Accessoires et piรจces dรฉtachรฉes ยป.

Avant stockage ou expรฉdition

โ€“ Rincez le bras de perfusion avec de lโ€™alcool isopropylique ร  60 % ou de lโ€™รฉthanol ร  70 %. Ouvrez la vanne de drainage situรฉe sous le pied droit du simulateur.

Entretien

Entretien aprรจs chaque session de simulation Les mesures de prรฉvention suivantes doivent impรฉrativement รชtre respectรฉes afin de garantir la longรฉvitรฉ du simulateur SimJunior.

โ€“ ร‰teignez le systรจme SimPad, la Link Box et les PC.

โ€“ Rechargez les batteries si nรฉcessaire.

โ€“ Rincez le systรจme du bras de perfusion et purgez la jambe IO (laissez le capuchon situรฉ sous la jambe ouvert).

โ€“ Aprรจs chaque utilisation du bras de perfusion, rincez-le avec une solution dโ€™alcool isopropylique ร  60 % ou dโ€™รฉthanol ร  70 %.

โ€“ Nettoyez la peau avec un chiffon humide.

โ€“ Retirez les vรชtements ou les linges humides.

โ€“ ร‰liminez les rรฉsidus de ruban adhรฉsif ร  lโ€™aide dโ€™un chiffon humide ou dโ€™alcool ร  90ยฐ.

โ€“ Remplacez les modules usagรฉs ou endommagรฉs en fonction du degrรฉ dโ€™usure du simulateur.

โ€“ Remplacez les cรขbles et les connecteurs visiblement endommagรฉs.

โ€“ La rรฉvision et la maintenance des composants du simulateur doivent รชtre effectuรฉes ร  intervalles rรฉguliers par un personnel compรฉtent.

Effectuez systรฉmatiquement une opรฉration de maintenance :

โ€“ Si du liquide a รฉtรฉ renversรฉ dans ou sur le simulateur.

โ€“ Aprรจs toute utilisation dans des environnements poussiรฉreux.

Page 37: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

35

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Entretien

Ouverture du tronc

Vous pouvez ouvrir le tronc du simulateur pour rรฉaliser certaines procรฉdures, notamment :

โ€“ Installation ou remplacement de membres

โ€“ Remplacement de la batterie du simulateur

โ€“ Remplacement du coussinet pour soulรจvement de la poitrine et de la poche pulmonaire

โ€“ Remplacement de la peau du torse

โ€“ Inspection gรฉnรฉrale

Avertissement : ouvrez le tronc de la gauche vers la droite et dรฉcrochez la peau avec prรฉcaution. Ne tirez pas la peau du torse vers le haut, car vous risquez dโ€™endommager les cรขbles de la poitrine.

1. Retirez la peau du torse en dรฉcrochant les attaches situรฉes ร  gauche du tronc et sur chaque รฉpaule.

Remplacement de la batterie du simulateur

1. Ouvrez le tronc du simulateur.

2. Rabattez la peau du torse vers la droite.

3. Dรฉconnectez le cรขble du connecteur de dรฉfibrillation.

4. Le cรขble du connecteur de dรฉfibrillation doit รชtre dรฉconnectรฉ du cรดtรฉ droit du simulateur, sous la courbe de la poitrine.

Remarque : NE dรฉbranchez PAS les tubes et les cรขbles qui relient la mousse du ventre au simulateur.

5. Replacez la peau du torse en exรฉcutant les รฉtapes 1 ร  4 dans lโ€™ordre inverse.

2. Faites glisser la batterie hors de son logement.

3. Tirez le cรขble รฉlectrique de la batterie situรฉ ร  lโ€™intรฉrieur du simulateur vers le haut, puis dรฉcrochez le cรขble รฉlectrique de la batterie.

4. Retirez la batterie du simulateur.

5. Replacez la batterie chargรฉe ou installez une nouvelle batterie SimJunior agrรฉรฉe par Laerdal.

6. Raccordez la batterie au simulateur.

7. Remettez la peau du torse en place.

Page 38: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

36

Entretien

Chargement de la batterie du simulateur

La batterie du simulateur se charge automatiquement en cours dโ€™utilisation. Si nรฉcessaire, il est รฉgalement possible de la charger ร  lโ€™aide dโ€™un adaptateur รฉlectrique externe (en option).

1. Mettez le simulateur hors tension via la Link Box.

2. Retirez la batterie du simulateur.

3. Raccordez un chargeur de batterie externe agrรฉรฉ (ร  lโ€™aide dโ€™un cordon dโ€™alimentation conforme aux normes locales en vigueur) ร  la partie infรฉrieure de la batterie du simulateur. Branchez le cordon dโ€™alimentation du chargeur ร  une prise murale.

4. Une fois la batterie entiรจrement chargรฉe, replacez-la dans le simulateur.

Remplacement du coussinet pour soulรจvement de la poitrine Le coussinet pour soulรจvement de la poitrine se situe dans la partie infรฉrieure de la plaque thoracique, entre les deux poumons.

1. Ouvrez la peau du torse pour exposer la plaque poitrine. Reportez-vous ร  Ouverture du tronc.

2. Dรฉconnectez la tubulure transparente de la poche pulmonaire, puis retirez cette derniรจre. Pour plus dโ€™informations, reportez-vous ร  Remplacement de la poche pulmonaire.

3. Dรฉconnectez la tubulure transparente du coussinet pour soulรจvement de la poitrine.

4. Jetez lโ€™ancien coussinet.

5. Insรฉrez un nouveau coussinet.

6. Reconnectez la tubulure au nouveau coussinet.

7. Fermez le tronc, puis remettez la peau du torse en place.

Remplacement de la poche pulmonaire En cas de fuite, la poche pulmonaire (situรฉe dans la cavitรฉ thoracique) doit รชtre remplacรฉe.

1. Ouvrez la peau du torse.

2. Dรฉconnectez la tubulure transparente de chaque cรดtรฉ de la poche pulmonaire. Reportez-vous ร  lโ€™illustration de lโ€™รฉtape 2 de la section Remplacement du coussinet pour soulรจvement de la poitrine.

3. Dรฉbranchez le clip de la poche pulmonaire situรฉ en haut, au centre.

4. Retirez la poche pulmonaire en tirant doucement la partie centrale supรฉrieure vers le haut.

5. Inversez les รฉtapes pour installer la nouvelle poche pulmonaire.

Page 39: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

37

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Remplacement des surfaces cutanรฉes du simulateur Les surfaces cutanรฉes du simulateur doivent รชtre remplacรฉes si elles sont dรฉchirรฉes, perforรฉes ou tachรฉes.

Peau du torse :

Pour remplacer la peau du torse du simulateur, reportez-vous ร  Ouverture du tronc.

Peau du bras :

Pour remplacer la peau du bras du simulateur, procรฉdez comme suit :

1. Retirez la peau usagรฉe du bras du simulateur en la faisant glisser vers le bas ou en la coupant*.

Pour monter le nouveau bras, procรฉdez comme suit :

Entretien

Remplacement du bras droit (bras de perfusion)

1. Ouvrez le tronc (reportez-vous ร  Ouverture du tronc).

2. Dรฉmontez le bras usagรฉ en dรฉvissant le boulon qui le maintient ร  lโ€™รฉpaule du simulateur.

3. Assurez-vous que la vis de lโ€™รฉpaule est assez desserrรฉe pour permettre ร  lโ€™axe du bras de glisser facilement vers lโ€™extรฉrieur.

4. Jetez le bras usagรฉ conformรฉment aux directives.

1. Veillez ร  ce que la vis de lโ€™รฉpaule soit suffisamment desserrรฉe pour que lโ€™axe du bras glisse facilement jusquโ€™ร  son emplacement.

2. Reliez le bras aux points de fixation correspondants sur le tronc.

3. Poussez dรฉlicatement lโ€™axe du bras sur la fixation dโ€™รฉpaule, de faรงon ร  ce que lโ€™axe soit dans lโ€™alignement de la partie interne de la fixation.

4. Serrez la vis de lโ€™รฉpaule ร  lโ€™aide dโ€™une clรฉ Allen.

Remplacement de la jambe droite (jambe IO) Pour dรฉmonter la partie infรฉrieure de la jambe droite, procรฉdez comme suit :

1. Assurez-vous que la jambe a รฉtรฉ purgรฉe de tout liquide.

2. Dรฉmontez la partie infรฉrieure de la jambe IO usagรฉe en dรฉvissant le boulon la maintenant ร  la cuisse.

3. Retirez cette partie en la faisant glisser.

4. Jetez la partie infรฉrieure de la jambe IO usagรฉe conformรฉment aux directives.

Le montage de la nouvelle partie infรฉrieure sโ€™effectue dans lโ€™ordre inverse.

Avertissement : *veillez ร  ne pas perforer ou couper le mandrin du bras.

2. Jetez la peau usagรฉe.

3. Lubrifiez lโ€™intรฉrieur de la nouvelle peau du bras avec un dรฉtergent liquide doux mรฉlangรฉ ร  de lโ€™eau.

4. Lubrifiez (ou savonnez) le mandrin avec un mรฉlange dโ€™eau et de savon liquide doux.

5. Faites glisser la main du simulateur dans la peau.

6. Enfilez les doigts du simulateur dans la peau, comme sโ€™il sโ€™agissait dโ€™un gant.

7. Faites glisser la peau vers le haut, par-dessus le mandrin du bras.

Page 40: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

38

Guide de dรฉpannage

Configuration du systรจme

Problรจme

โ€ข Donnรฉes perdues ou dรฉfaillance totale du systรจme (panne gรฉnรฉrale du systรจme).

Solution possible

โ€ข En cas dโ€™arrรชt du systรจme ou de perte/corruption de lโ€™ensemble des donnรฉes, contactez le centre de service technique Laerdal local.

LLEAPโ€ข Accรฉdez ร  Fichiers dโ€™aide du logiciel > LLEAP > Guide de

dรฉpannage. (Lโ€™aide est accessible ร  partir de Laerdal Simulation Home.)

Laerdal Patient Monitorโ€ข Accรฉdez ร  Fichiers dโ€™aide du logiciel > Laerdal Patient Monitor >

Guide de dรฉpannage. (Lโ€™aide est accessible ร  partir de Laerdal Simulation Home.)

Dรฉbriefing et enregistrement vidรฉoโ€ข Consultez la section relative au dรฉpannage de lโ€™aide SimView

(accessible ร  partir dโ€™un lien au bas de lโ€™รฉcran dans SimView) ou le guide de dรฉpannage de lโ€™aide SessionViewer (accessible depuis Laerdal Simulation Home).

Simulateur

Problรจme

โ€ข Comportement imprรฉvisible.

Solutions possibles

โ€ข Les dysfonctionnements du simulateur peuvent รชtre dus ร  des cรขbles, des tubes ou des connecteurs desserrรฉs. Ouvrez le tronc et vรฉrifiez si lโ€™un des composants fuit ou paraรฎt dรฉconnectรฉ. Reportez-vous ร  la section ยซ Configuration du simulateur โ€” Ouverture du tronc ยป.

โ€ข En cas de fuite de liquide, รฉteignez le simulateur et contactez le service technique Laerdal.

Contamination des voies respiratoires

Problรจme

โ€ข Les voies respiratoires du simulateur ont รฉtรฉ contaminรฉes suite ร  une ventilation par bouche-ร -bouche.

Solution possible

โ€ข Nettoyez lโ€™extรฉrieur du simulateur ร  lโ€™aide de lingettes pour mannequin. Nettoyez lโ€™intรฉrieur de la cavitรฉ buccale ร  lโ€™aide de lingettes pour mannequin. Remplacez la poche pulmonaire (reportez-vous ร  la section ยซ Entretien โ€” Remplacement de la poche pulmonaire ยป).

Mouvement thoracique

Problรจme

โ€ข La poitrine du simulateur ne se soulรจve pas.

Solutions possibles

โ€ข Vรฉrifiez que le simulateur est sous tension.

โ€ข Dans SimPad ou LLEAP, vรฉrifiez les points suivants : โ€“ La frรฉquence respiratoire nโ€™a pas la valeur zรฉro.

โ€“ Le soulรจvement de la poitrine nโ€™est pas dรฉsactivรฉ.

โ€“ Un rythme de perfusion est dรฉfini pour lโ€™ECG.

โ€“ Vรฉrifiez quโ€™aucune complication des voies respiratoires nโ€™est dรฉfinie, par exemple une rรฉsistance ร  lโ€™air maximale ou un laryngospasme.

โ€“ Vรฉrifiez que le compresseur intรฉgrรฉ est activรฉ dans LLEAP. Reportez-vous ร  la section ยซ Mise hors tension du compresseur interne ยป.

โ€ข En cas dโ€™utilisation dโ€™une source externe dโ€™air comprimรฉ, vรฉrifiez quโ€™elle est dรฉsactivรฉe et que le tube dโ€™alimentation en air est dรฉconnectรฉ du simulateur.

โ€ข Le compresseur interne est peut-รชtre en surchauffe. Patientez environ 20 minutes pour lui permettre de refroidir.

โ€ข Le soulรจvement de la poitrine est dรฉfini comme รฉtant bilatรฉral (par exemple, si la sonde endotrachรฉale est introduite trop loin dans les bronches).

โ€ข Le coussinet pour soulรจvement de la poitrine fuit ou la tubulure menant ร  ce coussinet est tordue, coincรฉe ou dรฉconnectรฉe. En cas de fuite, remplacez le coussinet pour soulรจvement de la poitrine (reportez-vous ร  ยซ Entretien โ€“ Remplacement du coussinet pour soulรจvement de la poitrine ยป).

โ€ข Vรฉrifiez que la tubulure dโ€™alimentation en air ne fuit pas ; vรฉrifiez que toutes les connexions sont intactes. En cas de fuite, remplacez la tubulure.

โ€ข Les mouvements thoraciques sont faibles et le compresseur interne fonctionne en continu. Il se peut que le compresseur interne soit endommagรฉ. Contactez le service technique Laerdal.

Page 41: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

39

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Guide de dรฉpannage

Poumons

Problรจme

โ€ข Les poumons ne fonctionnent pas correctement.

Solutions possibles

โ€ข Ouvrez le tronc et la plaque thoracique. Vรฉrifiez que les poumons ont suffisamment de place pour se gonfler et quโ€™ils ne sont gรชnรฉs par aucun cรขble.

โ€ข Vรฉrifiez que la poche pulmonaire est correctement raccordรฉe et que les tubes ne sont pas tordus.

โ€ข Vรฉrifiez que la poche pulmonaire est en position horizontale et quโ€™elle est correctement insรฉrรฉe.

โ€ข Recherchez dโ€™รฉventuels dรฉfauts ou dรฉchirures dans la poche pulmonaire.

โ€ข Vรฉrifiez quโ€™aucun obstacle dans les voies respiratoires du simulateur ne bloque lโ€™รฉcoulement de lโ€™air.

โ€ข Si le rรฉglage de la compliance pulmonaire ne produit aucun effet, contactez le service technique Laerdal.

โ€ข Si la rรฉsistance pulmonaire ne varie pas, contactez le service technique Laerdal.

Bruit mรฉcanique lors de lโ€™auscultationDans LLEAP, cliquez sur <Foyer dโ€™auscultation>.

Pouls (radial et brachial)

Problรจme

โ€ข Le pouls nโ€™est pas dรฉtectable.

Solutions possibles

โ€ข Il est possible que la peau soit trop tendue sur les unitรฉs de pouls. Ajustez la peau et rรฉinitialisez le systรจme.

โ€ข Assurez-vous que la tension artรฉrielle est dรฉfinie sur 60 au moins (pression systolique).

โ€ข Assurez-vous que le compresseur est activรฉ.

Remarque : lorsque la valeur dรฉfinie pour le pouls radial est infรฉrieure ร  60, les pulsations pรฉriphรฉriques peuvent disparaรฎtre.

Arrรชt du simulateur

Problรจme

โ€ข Le simulateur ne rรฉpond pas.

Solution

1. ร‰teignez la Link Box.

2. ร‰teignez SimPad ou, si vous utilisez LLEAP, รฉteignez le PC du formateur.

3. Redรฉmarrez ces รฉlรฉments.

Si le simulateur ne rรฉpond toujours pas, contactez votre reprรฉsentant Laerdal.

Page 42: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

40

Notes

Page 43: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

41

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Caractรฉristiques techniques

Dimensions globales Longueur/largeur (simulateur seul) : 120 cm x 42,5 cm Poids (simulateur seul) : 11,36 kg

Alimentation du simulateur Alimentation externe : Tension dโ€™entrรฉe 9 VCC, 1,5 A Batterie interne : 7,4 V, 4,4 Ah, lithium-ion

Sources dโ€™alimentation externes et batteries SimJunior agrรฉรฉes uniquement.

Pression dโ€™air Rรฉservoir dโ€™air interne : 6 psi max. Raccord dโ€™air externe : 16 psi max.

Limites de tempรฉrature Tempรฉratures de fonctionnement : +4 ยบC ร  40 ยบC Tempรฉratures de stockage: -15 ยบC ร  50 ยบC

Environnement โ€” Simulateur uniquement Humiditรฉ relative : 20 ร  90 % (sans condensation) NE PAS utiliser en plein air par temps humide. Non testรฉ au brouillard salin.

Communication RF Plage de fonctionnement : 10 m max.

Tableau des matรฉriaux utilisรฉs pour le simulateur Vรชtements : Coton, nylon Surfaces cutanรฉes et voies respiratoires : PVC Plastiques durs extรฉrieurs : PVC, ABS Plastiques intรฉrieurs : Silicone, TPU, PVC, nitrile ABS, POM, nylon + GF ร‰poxy-polyurรฉthane Composants mรฉtalliques : Aluminium, laiton, acier

Configuration minimale requise

โ€ข Intel i-core 3e gรฉnรฉration ou supรฉrieur

โ€ข Note supรฉrieure ร  3 000 PassMark โ€” CPU Mark

โ€ข 4 Go de RAM

โ€ข Espace de 120 Go sur le disque dur

โ€ข 1366 x 768 ou supรฉrieur

โ€ข Casque avec microphone

โ€ข 2 ports USB

Configuration logicielle minimale requise

โ€ข Windows 7 ou Windows 8

โ€ข DPI 100 %

Liquides de nettoyage Nettoyez le simulateur ร  lโ€™aide de lโ€™un des produits suivants uniquement :

โ€“ Alcool isopropylique ร  60 %

โ€“ ร‰thanol ร  70 %

โ€“ Solution douce dโ€™eau et de savon liquide

Liquides intraveineux Utilisez uniquement de lโ€™eau distillรฉe ou dรฉsionisรฉe pour simuler les liquides intraveineux et intra-osseux.

Page 44: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

42

Notes

Page 45: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

43

Logi

ciel

de

sim

ulat

ion

Con

figur

atio

n

du s

imul

ateu

rEn

tret

ien

Acc

esso

ires

et

piรจc

es

dรฉta

chรฉe

sC

arac

tรฉri

stiq

ues

te

chni

ques

Intr

oduc

tion

Gui

de d

e dรฉ

pann

age

Accessoires et piรจces dรฉtachรฉes

Accessoires et piรจces detaches

Pour obtenir la derniรจre version des accessoires et piรจces detaches disponibles, consultez le site www.laerdal.com

Page 46: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

44

Notes

Page 47: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

45

Wartung 56

โ€“ Wartung nach jeder Simulationssitzung 56 โ€“ ร–ffnen des Torsos 57 โ€“ Auswechseln des Simulator-Akkus 57 โ€“ Aufladen des Simulator-Akkus 58 โ€“ Auswechseln der Blase fรผr die Brustkorbhebung 58 โ€“ Auswechseln der Lungenblase 58 โ€“ Ersetzen der Simulatorhaut 59 โ€“ Auswechseln des rechten IV-Arms 59 โ€“ Auswechseln des rechten IO-Beins 59

Fehlerbehebung 60

Einfรผhrung 46

โ€“ Gesetzliche Anforderungen 46 โ€“ Allgemeine Pflegehinweise fรผr den Simulator 47โ€“ SimJunior รœbersichtsbild 49 โ€“ Merkmale des SimJunior 50

Simulatoreinrichtung 53

โ€“ Vorbereiten von Simulationen 53 โ€“ Vorbereiten des IO-Beins 53 โ€“ Verabreichen von IV-Flรผssigkeiten 53 โ€“ Ablauf intravenรถs verabreichter Flรผssigkeit 54 โ€“ Reinigen des IV-Arms 54 โ€“ Installieren der Adapterplatten fรผr die Defibrillation 54 โ€“ Anschluss der Blutdruckmanschette 54 โ€“ Kalibirieren der Blutdruckmanschette in LLEAP 54 โ€“ Kalibrieren der Blutdruckmanschette im SimPad 54โ€“ Auswechseln der Pupillen 55 โ€“ Verwendung eines externen Kompressors 55

Technische Daten 63

Simulationssoftware 52

โ€“ Ausbilder-PC 52 โ€“ Softwarelizenz 52 โ€“ Laerdal Simulation Home 52โ€“ LLEAP 52โ€“ Voice Conference Application 52โ€“ Patient Monitor 52โ€“ Session Viewer und SimView Server 52โ€“ Weitere Anwendungen 52โ€“ SimDesigner 52โ€“ Hilfedateien 52โ€“ Internet-Downloads 52

Ersatzteile und Zubehรถr 65

Inhaltsverzeichnis DE

Page 48: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

46

Li-ion

Einfรผhrung

Einfรผhrung zum SimJuniorโ„ข-Simulator SimJunior ist ein realistischer, lebensgroรŸer Pรคdiatrie-Patientensimulator, der von Laerdal in Kooperation mit der American Academy of Pediatrics entwickelt wurde. SimJunior dient der Schulung von medizinischem und Pflege-Fachpersonal und Teams aus vielen verschiedenen medizinischen Fachbereichen.

Der SimJunior-Simulator wird vollstรคndig montiert geliefert. Die Montage einzelner Komponenten des Trainingsmodells ist nicht erforderlich.

Informationen zur Vorbereitung des SimJunior fรผr Simulationen finden Sie im Abschnitt Simulatoreinrichtung.

SimJunior-Hilfe Gebrauchsanleitung

Schrittweise Anleitung mit Illustrationen zum Gebrauch des SimJunior-Simulators.

Originalbedienungsanleitung des Herstellers

Alle separaten Benutzerhandbรผcher und Kennzeichnungen der Originalhersteller sind zu befolgen. Die SimJunior-Gebrauchsanleitung ersetzt nicht die Bedienungsanleitung eines anderen Medizinproduktes.

Schnellanleitung zum Einrichten von SimJunior

Schrittweise Anleitung zur Einrichtung des SimJunior-Simulationssystems

SimPad-Gebrauchsanleitung

Die SimPad-Bedienungsanleitung beinhaltet Anweisungen zur Verwendung der Link Box und von SimPad zusammen mit SimJunior.

LLEAP-Hilfedateien (Laerdal Learning Application)

Die LLEAP-Hilfedateien sind รผber die Laerdal Simulation Home abrufbar ; siehe unter Laerdal Simulation Home

Hilfethemen sind u. a.:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

Technische Hilfe

Falls Sie technische Hilfe benรถtigen, wenden Sie sich bitte an Ihr zustรคndiges Technisches Laerdal Servicecenter vor Ort.

Internet-Downloads

Unter www.laerdal.com/downloads kรถnnen Sie die aktuelle Gebrauchsanweisung und neue Versionen der Simulationssoftware herunterladen.

SimCenter-Inhalt SimCenter bietet einfachen Zugriff auf validierte Inhalte von Simulationsexperten weltweit, sodass Sie sich deren Erfahrungen zunutze machen und den grรถรŸtmรถglichen Nutzen aus jeder Schulung ziehen kรถnnen. Hier finden Sie eine breite Palette an Szenarien, die speziell fรผr SimJunior entwickelt wurden. Besuchen Sie mysimcenter.com, um weitere Informationen zur vollstรคndigen Optimierung Ihrer Trainingserfahrung zu erhalten.

Gesetzliche Anforderungen Federal Communications Commission StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Vorsicht ร„nderungen oder Modifikationen an diesem Gerรคt, die nicht ausdrรผcklich von der fรผr die Einhaltung dieser Bestimmungen zustรคndigen Stelle genehmigt werden, kรถnnen dazu fรผhren, dass dem Benutzer der Betrieb des Gerรคtes untersagt wird.

Lithium-Ionen-Akkus mรผssen recycelt werden.

Haftungsausschluss Die Schulung des Personals mit Hilfe des SimJunior-Patientensimulators sollte unter Aufsicht durch entsprechend ausgebildete technische oder medizinische Fachkrรคfte erfolgen, die mit den Ausbildungsprinzipien sowie allgemein anerkannten medizinischen Vorschriften vertraut sind. Wie bei allen Simulatoren oder รคhnlichen Trainingsgerรคten kรถnnen Angleichungen, Abweichungen und Ungenauigkeiten bei anatomischen Merkmalen bzw. bei der physiologischen Modellbildung auftreten. Aus diesem Grund kann Laerdal keine Garantie fรผr die Genauigkeit sรคmtlicher Merkmale des Simulators รผbernehmen.

Laerdal Medical AS erklรคrt hiermit, dass dieses Produkt, sofern es mit der CE-Kennzeichnung versehen ist, den zentralen Anforderungen und sonstigen relevanten Bestimmungen der EU-Richtlinie 1999/5/EG entspricht.

Dieses Gerรคt ist unter Einhaltung der รถrtlichen Bestimmungen und Regelungen zu entsorgen.

Page 49: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ions

soft

war

eSi

mul

ator

einr

icht

ung

W

artu

ng

Ersa

tzte

ile u

nd

Zub

ehรถr

Tech

nisc

he D

aten

Ei

nfรผh

rung

Fe

hler

behe

bung

47

Einfรผhrung

Allgemeine Pflegehinweise fรผr den Simulator Befolgen Sie die nachstehenden Empfehlungen, um eine optimale Leistung und Langlebigkeit des Simulators und seiner Komponenten zu gewรคhrleisten.

Allgemeine Pflegehinweise

Waschen Sie zur Erhaltung der Simulatorhaut vor dem Gebrauch Ihre Hรคnde und legen Sie den Simulator auf eine saubere Oberflรคche. Laerdal empfiehlt:

โ€“ Tragen Sie wรคhrend der Simulationsszenarien Handschuhe. Verwenden Sie keine farbigen Kunststoffhandschuhe, da diese zu Verfรคrbungen der Simulatorhaut fรผhren kรถnnen.

โ€“ Verwenden Sie in der Nรคhe des Simulators keine Filzstifte oder Fรผller, kein Azeton oder Jod und keine sonstigen Tinkturen mit potentiell fรคrbender Wirkung. Legen Sie den Simulator nicht auf Zeitungen oder farbiges Papier. Es kรถnnen nicht entfernbare Flecken zurรผckbleiben.

โ€“ Reinigen Sie die Simulatorhaut mit milder Seife und Wasser.

Versuchen Sie nicht, eines der folgenden Verfahren an diesem Simulator durchzufรผhren, da es nicht mรถglich ist, die Atemwege hygienisch zu desinfizieren:

โ€“ Mund-zu-Mund-/Mund-zu-Maske-Beatmung

โ€“ Einfรผhrung von simuliertem Erbrochenem oder anderen Flรผssigkeiten fรผr das Absaugen

โ€“ Falls bei einer Trainingseinheit die Verwendung von Flรผssigkeiten im IV-Arm gefordert ist, lassen Sie die Flรผssigkeit unmittelbar nach der Schulungssitzung aus dem Arm ablaufen.

โ€“ Verwenden Sie ausschlieรŸlich das Laerdal-Atemwegsschmiermittel, und tragen Sie es sparsam auf.

โ€“ Spรผlen, reinigen und trocknen Sie die Komponentenmodule des Simulators.

โ€“ Ziehen Sie die Torsohaut zurรผck und pudern Sie die Innenseite der Torsohaut, um Reibung zu reduzieren. Bringen Sie keinen Puder in die Brusthรถhle des Simulators ein.

Umgebung Starten Sie den Simulator bei kalten Umgebungsbedingungen erst, wenn dieser Raumtemperatur erreicht hat.

So vermeiden Sie รœberhitzung und Abnutzungserscheinungen:

โ€“ Wenn Sie den Simulator bei Temperaturen รผber 40 ยฐC verwenden, lassen Sie ihn zwischen den Schulungssitzungen abkรผhlen.

โ€“ Wird der Simulator in einem Bett verwendet, decken Sie ihn nicht mit schwerem Bettzeug zu โ€“ dies wรผrde die Wรคrmeableitung von dem Simulator verhindern.

Allgemeine Hinweise zum Umgang mit dem Simulator Halten Sie sich an die folgenden VorsichtsmaรŸnahmen, um Verletzungen oder Schรคden am Produkt zu vermeiden:

โ€“ Fรผllen Sie Flรผssigkeiten nur auf die in diesem Dokument beschriebene Weise in den Simulator ein.

โ€“ Befeuchten Sie vor dem Einfรผhren eines Instruments, einer Sonde oder einer Atemwegshilfe die Atemwege in Mund und Nase mit dem dafรผr vorgesehenen Gleitmittel. Befeuchten Sie auch die Instrumente und Schlรคuche vor dem Gebrauch.

โ€“ Leiten Sie wรคhrend der Beatmung keine befeuchtete Luft in das System.

โ€“ Verwenden Sie den Simulator nicht, wenn die internen Schlรคuche und Kabel nicht angeschlossen sind.

โ€“ Verwenden Sie den SimJunior-Simulator unter keinen Umstรคnden bei Nรคsse im Freien, da dies die Gefahr eines Stromschlags oder einer Beschรคdigung des Simulators birgt.

โ€“ Die Verwendung eines Defibrillators bei Temperaturen รผber 35ยฐ C kann zu รœberhitzung fรผhren

Warnhinweis: Verwenden Sie an diesem Simulator keine automatischen Thoraxkompressionsgerรคte.

Vorsicht Latex: Dieses Produkt enthรคlt natรผrlichen Gummilatex, der bei Berรผhrung allergische Reaktionen beim Menschen hervorrufen kann.

Defibrillationsrisiken Das SimJunior-Modell kann fรผr Defibrillationsรผbungen verwendet werden.

Sie kรถnnen fรผr SimJunior einen konventionellen Defibrillator verwenden. Wรคhrend einer Defibrillation besteht das Risiko von Stromschlรคgen sowohl durch den Simulator als auch durch den Defibrillator. Wird beim Simulator ein Defibrillator eingesetzt, sind sรคmtliche standardmรครŸigen Sicherheitsvorkehrungen zu treffen.

โ€ข Lesen und befolgen Sie sรคmtliche Sicherheits- und Gebrauchsanweisungen, die fรผr Ihren Defibrillator und die dazugehรถrige Ausrรผstung gelten.

โ€ข Befolgen Sie das Defibrillationsprotokoll, indem Sie wรคhrend des Defibrillationsvorgangs jeglichen Kontakt zwischen den externen Paddles und sรคmtlichen Elektrodenpositionen vermeiden. Es ist eine Ladung von bis zu 300 Joule mรถglich.

โ€ข Die Nichtbefolgung der SicherheitsmaรŸnahmen kann zu Verletzungen oder gar zum Tod fรผhren.

Weitere Informationen finden Sie im Benutzerhandbuch Ihres Defibrillators.

Warnhinweise:

โ€“ Verwenden Sie bei der Durchfรผhrung von Defibrillationsvorgรคngen die auf dem Brustkorb des Simulators angebrachten Defibrillatoranschlรผsse oder Kontaktplatten. Verwenden Sie nicht die EKG-Anschlรผsse; diese sind ausschlieรŸlich fรผr die EKG-รœberwachung bestimmt. Eine Verwendung der EKG-Anschlรผsse zum Defibrillieren beschรคdigt die interne Elektronik des Simulators und kann zu Verletzungen von Personen fรผhren.

โ€“ Defibrillieren Sie den Simulator nicht in ausgeschaltetem Zustand oder wenn dieser nicht ordnungsgemรครŸ funktioniert.

Weltweite Garantie Siehe die Broschรผre โ€žLaerdals weltweite Garantieโ€œ bzw. unter www.laerdal.com.

Herkunftsland โ€“ SimJunior wird in den USA hergestellt.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 50: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

48

Einfรผhrung

Um ein รœberhitzen wรคhrend der Defibrillation zu vermeiden, darf eine Defibrillationssequenz von 3 Elektroschocks innerhalb von 45 Sekunden โ€“ gefolgt von 1 Minute Herz-Lungen-Reanimation โ€“ nicht รผberschritten werden. Stoppen Sie die Schockabgabe nach 30 Minuten fรผr mindestens 15 Minuten, bevor Sie mit der nรคchsten Sequenz beginnen. Wiederholen Sie diesen Vorgang nur fรผr eine Zeitdauer von maximal 4 Stunden. Verabreichen Sie nicht mehr als 2 x 300 J Defibrillatorenentladungen pro Minute.

Warnhinweise:

โ€“ Der Simulator darf wรคhrend des Defibrillationsvorgangs nicht mit elektrisch leitfรคhigen Oberflรคchen oder Gegenstรคnden in Berรผhrung kommen.

โ€“ Benutzen Sie das Trainingsmodell nicht in feuergefรคhrlicher Umgebung. Beispielsweise sollten hohe Werte reinen Sauerstoffs wรคhrend der Defibrillation vermieden werden. Bei Verwendung von konzentriertem Sauerstoff in der Nรคhe des Simulators ist fรผr gute Belรผftung zu sorgen.

โ€“ Der Torso des Simulators ist stets vor Nรคsse zu schรผtzen. โ€“ Defibrillieren Sie den Simulator erst nach einer Akklimatisierungszeit.

Plรถtzliche Temperaturschwankungen kรถnnen zu Kondensatbildung an elektronischen Komponenten fรผhren und so einen Stromschlag verursachen.

โ€“ Zur Vermeidung von Rost an den Hautelektroden des Torsos verwenden Sie kein leitfรคhiges Gel oder leitfรคhige Defibrillationspads, die fรผr den Gebrauch am Patienten bestimmt sind.

โ€“ Ein zu starkes Niederdrรผcken der Defibrillationsanschlรผsse wรคhrend des Defibrillationsvorgangs kann ebenfalls zu Funkensprung und Rostbildung fรผhren.

โ€“ Defibrillieren Sie den Simulator nicht, wenn die Haut nicht richtig platziert ist.

Mechanische bzw. elektrische Gefahren Verwenden Sie den SimJunior-Simulator nicht, wenn:

โ€“ die GliedmaรŸen nicht am Kรถrper befestigt sind. โ€“ die Haut angerissen oder nicht ordentlich befestigt ist. โ€“ interne bzw. externe Kabel, Schlรคuche oder Anschlรผsse

beschรคdigt sind. โ€“ Flรผssigkeit im oder am Simulator austritt. โ€“ ungewรถhnliche Gerรคusche auf Verlust von Druckluft oder

einen mechanischen Schaden hindeuten. โ€“ Anzeichen einer elektrischen Stรถrung vorhanden sind, etwa

wenn die Puppe nicht reagiert, ungewรถhnlich riecht oder qualmt.

Warnhinweis:

โ€“ Vermeiden Sie die Gefahr von Quetschungen und Einklemmungen โ€“ verwenden Sie den Simulator nicht ohne AuรŸenhaut

Akkubenutzung und -wartung โ€“ Verwenden Sie nur fรผr den Betrieb von SimJunior, Link Box und

SimPad zugelassene Akkus. โ€“ Stellen Sie sicher, dass die Akkus richtig eingesetzt sind. Ein

inkorrektes Einsetzen und AnschlieรŸen von Akkus kann einen Kurzschluss verursachen.

Warnhinweise:

โ€“ Entsorgen Sie die Akkus gemรครŸ den รถrtlich geltenden Bestimmungen.

โ€“ Das externe Akkuladegerรคt ist nur fรผr den Gebrauch im Innenbereich vorgesehen.

โ€“ Der Akku des Simulators sollte nur bei Temperaturen von 0 ยฐCโ€“40 ยฐC aufgeladen werden.

โ€“ Vermeiden Sie unsachgemรครŸe Behandlung, Demontage oder Reparaturversuche am Akku. Verwenden Sie keine Akkus, die sichtbar beschรคdigt sind, nicht funktionieren oder undicht zu sein scheinen.

โ€“ Vermeiden Sie den direkten Kontakt mit elektrischen, heiรŸen oder qualmenden Teilen. Sollte sich herausstellen, dass ein Akku undicht ist, trennen Sie diesen ab und entfernen Sie ihn, sofern dies gefahrlos mรถglich ist.

โ€“ Der Kontakt mit Flรผssigkeiten birgt eine Explosionsgefahr. โ€“ Nach jedem 30. Ladevorgang sollte der Akku vor dem

Wiederaufladen vollstรคndig entleert werden. Zum Entleeren des Akkus lassen Sie den Simulator auf Akku laufen, bis er sich automatisch abstellt.

โ€“ Ersetzen Sie den Akku ausschlieรŸlich durch einen Laerdal SimJunior-Akku.

Lagerung und Transport โ€“ Bewahren Sie vollstรคndig aufgeladene Akkus nicht lรคnger als einen

Monat auf. โ€“ Der Simulator-Akku kann wรคhrend des Transports per Luftfracht

im Simulator verbleiben. โ€“ Fรผr den Transport von Ersatzakkus erkundigen Sie sich bei der

Fluggesellschaft oder dem Frachtunternehmen nach den aktuellen Transportbestimmungen.

Warnhinweis:

โ€“ Der SimJunior-Simulator und die Zubehรถrteile sind schwer, wenn sie zusammen in einem Transportkoffer untergebracht sind. Stellen Sie stets sicher, dass der SimJunior wรคhrend des Transports und der Lagerung sicher verstaut ist, um Verletzungen und Beschรคdigungen am Produkt zu vermeiden.

Page 51: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ions

soft

war

eSi

mul

ator

einr

icht

ung

W

artu

ng

Ersa

tzte

ile u

nd

Zub

ehรถr

Tech

nisc

he D

aten

Ei

nfรผh

rung

Fe

hler

behe

bung

49

IO-Bein

Einfรผllรถffnung fรผr IO-Bein

SimJunior-Simulator

EKG-Anschluss rechter Arm

Sternum-Defibrillationsplatte

IV-Arm

EKG-Anschluss rechtes Bein

Netzkabel Externe Druckluftverbindung

Simulatorkabel (60-Pin)

Einfรผhrung

EKG-Anschluss linker Arm

Blutdruckarm

Apex-Defibrillati-onsplatte

EKG-Anschluss linkes Bein

Page 52: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

50

Einfรผhrung

SimJunior-Simulator SimJunior ermรถglicht das interaktive Training lebensrettender Fertigkeiten und reagiert auf klinische Interventionen durch Steuerung durch den Ausbilder und / oder vorprogrammierte Szenarien. Dies ermรถglicht effektives รœben von Diagnostik und Behandlung von Patienten.

Mit der spontanen Atemfunktion, Atemwegskontrolle, Stimme, Gerรคuschen, EKG und sonstigen klinischen Merkmalen stellt SimJunior ein vollstรคndig funktionsfรคhiges Pรคdiatrie-Simulatormodell dar. SimJunior ermรถglicht die Beobachtung und Erkennung der meisten Vitalzeichen, die es dem Ausbilder ermรถglicht, die Fertigkeiten der Schรผler auf der Grundlage realistischer klinischer Situationen zu beurteilen.

Merkmale des SimJunior

โ€“ Realistische Atemwege zur Simulation von schwierigem Atemwegsmanagement sowie zur oralen und nasalen Intubation

โ€“ Sichtbare Atmung

โ€“ Kardiale Merkmale einschlieรŸlich Defibrillation und Kardioversion

โ€“ Augen mit auswechselbaren Pupillen (normal, geweitet und verengt)

โ€“ Simulation von Krampfen

โ€“ Thoraxkompressionen

โ€“ Vaskulรคrer Zugang

โ€“ Normale und anormale Herz-, Atem- und Darmgerรคusche

โ€“ Automatische Simulationskontrolle auf der Grundlage vorprogrammierter und validierter Patientenszenarien

Durch die Verwendung von Szenarien im SimPad oder mit LLEAP (PC) kรถnnen Simulationen selbststรคndig laufen. Die Entwicklung des Patientenzustands ist vorprogrammiert und reagiert automatisch auf die Interventionen der Kursteilnehmer.

GesamtmaรŸe

Lรคnge/Breite (nur Trainingsmodell): 120 cm x 42,5 cm Gewicht (nur Simulator): 11,36 kg

SimJunior-Bekleidung

SimJunior wird mit speziell hergestellter Bekleidung mit Klettverschlรผssen zum leichteren Entfernen der Kleidung geliefert. Waschhinweise befinden sich auf dem Etikett am Kleidungsstรผck.

โ€“ Hemd

โ€“ Shorts

โ€“ Boxer-Shorts

Allgemeine klinische Merkmale Atemwegsmerkmale

Der Atemweg ist eine anatomisch korrekte Nachbildung der Luftrรถhre. Der Atemweg kann wie folgt manipuliert werden:

โ€“ รœberstrecken des Kopfes

โ€“ Esmarch-Handgriff durch beweglichen Kiefer

โ€“ Krikoiddruck und -manipulation

โ€“ Absaugen (oral oder nasopharyngeal)

Der Simulator kann beatmet werden:

โ€“ Maskenbeatmung mit Beutel

โ€“ Orotracheale Intubation

โ€“ Nasotracheale Intubation

Machen Sie den Atemweg vor Einfรผhren von Materialien zur Atemwegssicherung mit dem Laerdal Atemwegsgleitmittel gleitfรคhig.

Die folgenden Mรถglichkeiten bzw. Methoden werden zur Atemwegssicherung am Simulator empfohlen:

โ€“ Larynxmaske fรผr den Atemweg (GrรถรŸe 2,5)

โ€“ Endotrachealtubus (GrรถรŸe ID 4,5 mit Manschette, 5,5 ohne Manschette)

Empfohlen wird die Verwendung eines elastischen Mandrins. Stellen Sie sicher, dass dieser nicht รผber den ET-Tubus hinausreicht.

Die folgenden Simulatorzustรคnde deuten auf eine inkorrekte Tubusplatzierung hin:

โ€“ Einseitiges Anheben des Brustkorbs bei Intubation in den rechten Hauptbronchus

โ€“ Bauchblรคhung

โ€“ Fehlende Gerรคusche im Brustraum (siehe Abschnitt รผber Atmung)

Die Eigenschaften des Simulators kรถnnen zur Darstellung verschiedener Atemwegszenarien konfiguriert werden:

โ€“ Zungenรถdem โ€“ Normal-, Mittel-, Maximal

โ€“ Lunge offen oder geschlossen

Atmung

SimJunior kann spontane Atmung mit sichtbarer Brustkorbhebung und โ€“senkung sowie variabler Atemfrequenz simulieren. Die Atmung wird durch einen Kompressor im rechten Oberschenkel des Simulators erzeugt.

โ€“ Beidseitiges Heben und Senken des Brustkorbs bei Spontanatmung

โ€“ Einseitiges Heben und Senken des Brustkorbs bei Intubation in den rechten Hauptbronchus wรคhrend der Beatmung

โ€“ Einseitige und beidseitige Lungengerรคusche

โ€“ Normale und pathologische Atemgerรคusche

โ€“ Variable Atemfrequenz (0โ€“60 Atemzรผge pro Minute)

โ€“ Anteriore Auskultationsstellen (4)

Linker und rechter Lungenflรผgel kรถnnen unabhรคngig voneinander oder zusammen verschlossen werden, um eine partielle oder vollstรคndige Atemwegsobstruktion zu simulieren. Der SimJunior-Simulator kann auch fรผr unterstรผtzte Beatmung verwendet werden.

Hinweis: Die Lungen sind nicht zur Verwendung mit PEEP-Ventilen geeignet.

Page 53: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ions

soft

war

eSi

mul

ator

einr

icht

ung

W

artu

ng

Ersa

tzte

ile u

nd

Zub

ehรถr

Tech

nisc

he D

aten

Ei

nfรผh

rung

Fe

hler

behe

bung

51

Einfรผhrung

Kreislaufmerkmale

Kardialmerkmale:

โ€“ Umfassende EKG-Bibliothek, Pulsfrequenzen von 0โ€“200

โ€“ Herzgerรคusche โ€“ vorderer Bereich (1)

โ€“ รœberwachung des EKG-Rhythmus (4 Pole, 3-Kanal-EKG)

โ€“ 12-Kanal-EKG-Anzeige (nur bei Verwendung von LLEAP)

โ€“ Pacing

โ€“ Defibrillation und Kardioversion durch klinische Defibrillatoren

Defibrillation:

โ€“ Die Anzahl der fรผr eine automatische Konversion benรถtigten Schocks werden fรผr jeden simulierten Patientenfall festgelegt

Defibrillationsanschlรผsse:

3-Kanal-EKG-Anschlรผsse:

Blutdruck und Pulsfrequenzen:

โ€“ Manuelle Blutdruckmessung durch Auskultation der Korotkoff-Gerรคusche

โ€“ Beidseitiger Karotispuls

โ€“ Zentrale Pulse lassen sich auf โ€žnormalโ€œ, โ€žschwachโ€œ und โ€žkein Pulsโ€œ einstellen

โ€“ Radial-/Brachialpuls lassen sich auf โ€žnormalโ€œ, โ€žschwachโ€œ und โ€žkein Pulsโ€œ einstellen

โ€“ Mit EKG synchronisierter Karotis-, Brachial- und Radialpuls

โ€“ Variable Pulsstรคrke je nach Blutdruck

โ€“ Erkennung und Protokollierung des Tastens von Pulsen

CPR-Merkmale

โ€“ Konform mit den Guidelines 2010

โ€“ Kompressionen erzeugen tastbare Pulse, eine Blutdruckkurve und EKG-Artefakte

โ€“ Realistische Kompressionstiefe und Kompressionswiderstand

โ€“ Erkennung der Tiefe und Frequenz von Kompressionen

Vaskulรคre Merkmale

IV-Zugang:

Ein IV-Zugang ist am rechten Arm und an der rechten Hand mรถglich. Der IV-Arm kann fรผr den IV-Zugang, Infusion und Bolus an folgenden Stellen eingestellt werden:

โ€“ Periphere Venen des Unterarms

โ€“ Ellenbogen-Beuge und Handrรผcken

Intraossรคrer Zugang (IO):

Ein Zugang fรผr IO-Infusionen ist an folgenden Stellen mรถglich:

โ€“ Tuberositas tibiae (rechts)

โ€“ Medialer Malleolus

Hinweis: SimJunior verfรผgt รผber keine intramuskulรคren (IM) Injektionsstellen. Versuchen Sie nicht, eine intramuskulรคre Injektion vorzunehmen.

Toneinstellungen fรผr SimJunior SimJunior verfรผgt รผber zahlreiche Stellen fรผr die Auskultation und Erkennung von Herz-, Lungen- und Darmgerรคuschen. SimJunior ermรถglicht auch die Wiedergabe von Stimmgerรคuschen.

Weitere Informationen รผber die Toneinstellungen fรผr SimJunior finden Sie in der SimPad-Gebrauchsanleitung oder in den LLEAP-Hilfedateien.

Page 54: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

52

Simulationssoftware

Ausbilder-PC

Der Ausbilder-PC arbeitet mit der LLEAP-Software, um Simulationssitzungen zu leiten. LLEAP sowie weitere Simulationsanwendungen werden รผber die Laerdal Simulation Home aufgerufen.

Softwarelizenz Der Ausbilder-PC wird von Laerdal mit einer vorinstallierten voraktivierten LLEAP-Lizenz geliefert.

Bei ร„nderungen oder Aktualisierungen der Computer-Hardware (z. B. eine neue Festplatte oder Hauptplatine) kann Ihre Lizenz ungรผltig werden. Bitte wenden Sie sich an Ihren รถrtlichen Laerdal Kundendienst, wenn Sie Hilfe bei der Neuaktivierung Ihrer Lizenz benรถtigen.

Laerdal Simulation HomeLaerdal Simulation Home ist eine Anwendung, aus der LLEAP und andere Laerdal-Programme im Zusammenhang mit der Patientensimulation gesucht und gestartet werden kรถnnen. Auch die Hilfedateien lassen sich dort รถffnen. Laerdal Simulation Home befindet sich im Ordner โ€žLaerdal Medicalโ€œ im Windows-Startmenรผ (Windows 7).

Die wรคhrend einer Simulationssitzung verwendete Software lรคsst sich in folgende Hauptanwendungen unterteilen:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor Application

โ€“ SimView Server oder Session Viewer

Zusรคtzlich werden SimDesigner und andere Anwendungen fรผr das Entwickeln und Vorbereiten einer Simulation verwendet.

LLEAPDie Laerdal Learning Application (LLEAP) ist die Ausbilderanwendung, รผber die die Simulationssitzung ausgefรผhrt, gesteuert und รผberwacht wird. LLEAP kann im manuellen oder im Automatikmodus verwendet werden. Der Automatikmodus wird fรผr vorprogrammierte Szenarios verwendet, wรคhrend der manuelle Modus dem Ausbilder die volle manuelle Kontrolle รผber die Simulationssitzung bietet. Das Ausfรผhren von Simulationen im manuellem Modus erfordert im Allgemeinen ein gewisses MaรŸ an medizinischer Erfahrung zur Erstellung klinisch passender Simulationen.

Voice Conference Application (VCA)Die VCA-Software dient dazu, wรคhrend der Simulation sรคmtliche Stimmgerรคusche zu รผbertragen. Sie ermรถglicht dem Ausbilder, wรคhrend der Sitzung รผber den Simulator zu kommunizieren. VCA kann auรŸerdem zur Kommunikation mit anderen Ausbildern in einem Netzwerk und zur Erstellung separater Kanรคle genutzt werden, รผber die nur Mitglieder miteinander sprechen kรถnnen.

Patient MonitorDie Patient Monitor-Application bildet einen typischen klinischen Patientenmonitor nach. Dies ist das Bedienfeld des Schรผlers, das sich durch den Ausbilder wie auch durch den Schรผler รผber ein Touchscreen-Menรผsystem einrichten und steuern lรคsst.

Session Viewer und SimView ServerBei Session Viewer und SimView Server handelt es sich um Anwendungen, die Videos und Bildschirmerfassungen des Patientenmonitors wรคhrend der Simulation aufzeichnen. Zusรคtzlich bieten sie eine Oberflรคche fรผr das Debriefing Ihrer Sitzung. Nach dem Ende einer Sitzung werden in LLEAP erstellte Protokolldateien รผbertragen und in Session Viewer oder SimView Server fรผr das Debriefing mit Videodateien zusammengefรผhrt.

Der Session Viewer lรคuft gewรถhnlich lokal auf demselben Computer, der fรผr LLEAP genutzt wird; SimView Server wird auf einem zugewiesenen Server im lokalen Netzwerk ausgefรผhrt. Wรคhrend des ersten Starts von LLEAP werden Sie aufgefordert, ein auf Ihrem Computer oder im lokalen Netzwerk verfรผgbares Debriefing-System auszuwรคhlen. Dies kann spรคter geรคndert werden.

Weitere AnwendungenWeitere Programme, die in Verbindung mit den Simulationssitzungen verwendet werden, sind z. B. License Manager zur Verwaltung von Programmlizenzen sowie Simulator Firmware & Network Wizard zum Aktualisieren der Simulator-Firmware bzw. zum Beheben von Netzwerkproblemen.

SimDesignerSimDesigner ist eine Anwendung zur Konfiguration Ihrer eigenen vorprogrammierten Szenarien. Es kann auch zur Analyse und zum Drucken einer grafischen Ansicht des programmierten Szenarios verwendet werden.

SimDesigner muss installiert sein, um die Konvertierung von Legacy-Ausbilderanwendungsdateien in LLEAP-kompatible Dateiformate durchfรผhren zu kรถnnen.

Hilfedateien

Weitere Informationen รผber die LLEAP-Software und weitere Anwendungen finden Sie in den Hilfedateien:

1. Klicken Sie in Windows auf die Schaltflรคchen <Start> und <Alle Programme>.

2. Wรคhlen Sie die <Laerdal Simulation Home>.

3. Wรคhlen Sie <Hilfe> aus.

Internet-DownloadsUnter www.laerdal.com/downloads kรถnnen Sie das aktuelle Benutzerhandbuch und die Software herunterladen.

Page 55: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

53

Sim

ulat

ions

soft

war

eW

artu

ng

Ersa

tzte

ile u

nd

Zub

ehรถr

Tech

nisc

he D

aten

Ei

nfรผh

rung

Si

mul

ator

einr

icht

ung

Fe

hler

behe

bung

Simulationssoftware

Vorbereiten von Simulationen Nach der Vorbereitung des SimJunior-Simulators und der Konfiguration und Bereitstellung sรคmtlicher einsetzbarer interaktiver Gerรคte (SimPad oder Instructor PC und Patientenmonitor) mรผssen eventuell noch einige letzte Vorbereitungen getroffen werden, bevor der SimJunior simulationsbereit ist.

Zu den letzten Simulationsvorbereitungen zรคhlen u. a.:

โ€ข Vorbereiten des IO-Beins

โ€ข Verabreichen von intravenรถs-Flรผssigkeiten

โ€ข Ablauf intravenรถs verabreichter Flรผssigkeiten

โ€ข Reinigen des IV-Arms

โ€ข Anschluss der Adapterplatten fรผr die Defibrillation

โ€ข Anschluss der Blutdruckmanschette

โ€ข Auswechseln der Pupillen

โ€ข AnschlieรŸen eines externen Kompressors

โ€ข ร„ndern der Einstellungen des internen Kompressors

Vorbereiten des IO-Beins Das rechte Bein des Simulators ist so konstruiert, dass es sich zur Schulung intraossรคrer Infusionstechniken eignet. Die Anatomie des rechten Beins beinhaltet das Knie, die Tibia, die Tuberositas tibiae und den Malleolus medialis. Das rechte Bein wird mit einem Infusionssystem sowie einem IV-Beutel geliefert, der wรคhrend der Infusion als Reservoir dient.

Zusรคtzlich erforderliche Ausstattungsteile:

โ€ข IV-Beutel und Infusionssystem

โ€ข Simuliertes Blutkonzentrat

โ€ข Eine groรŸe-Injektionsspritze (35 cc) sowie eine 1,3 mm (16-Gauge) intraossรคre Kanรผle

Fรผllen des IO-Beins und Vorbereitung fรผr den Gebrauch:

1. Heben Sie das Bein vertikal an.

2. ร–ffnen Sie den Stรถpsel an der Ferse.

3. Fรผllen Sie den Knochen unter Verwendung einer Injektionsspritze mit ca. 240 bis 250 cc simulierten Bluts.

4. SchlieรŸen Sie die mit einem IV-Beutel verbundenen Schlรคuche an. (Verwenden Sie eine Rollenklemme zum ร–ffnen oder SchlieรŸen der Verbindungsleitung, um bei Bedarf Druck abzulassen.)

5. Klemmen Sie den in den Beutel hineinfรผhrenden Schlauch ab, damit das Simulationsblut zum Aspirieren im Knochen bleibt.

6. Stoppen Sie die Medikamentengabe, sobald der Beutel gefรผllt ist, und ersetzen Sie ihn durch einen leeren Beutel.

Vor der Lagerung des Simulators:

โ€“ Lรถsen Sie die IV-Verbindung und den Beutel vom FuรŸ

โ€“ Lassen Sie die gesamte Flรผssigkeit auslaufen

โ€“ Lagern Sie das Bein mit herausgezogenem Stรถpsel, um es an der Luft trocknen zu lassen

Hinweis: Verwenden Sie keine Kochsalzlรถsung. Sie kรถnnte das Bein beschรคdigen. Verwenden Sie destilliertes oder entionisiertes Wasser, um eine Ansammlung von Mineralien zu vermeiden.

Verabreichen von IV-Flรผssigkeiten Der rechte Arm lรคsst sich zur Schulung fรผr die intravenรถse Verabreichung von Arzneien als Infusionen sowie Boli in die peripheren Venen des Unterarms, in die Ellenbogen-Beuge und den Handrรผcken nutzen.

Verwenden Sie eine 0,812 mm-0,644 mm (20- bis 22-Gauge)-Kanรผle zur IV-Simulation. Verwenden Sie bei der Simulation von intravenรถs verabreichten Medikamenten zur Vermeidung einer Verstopfung des IV-Systems ausschlieรŸlich destilliertes oder entionisiertes Wasser.

Page 56: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

54

Simulationssoftware

Ablauf intravenรถs verabreichter Flรผssigkeiten Das IV-Flรผssigkeitssystem ist ein offenes System. IV-Flรผssigkeiten laufen ab, sobald sie verabreicht werden.

Vor jeder Sitzung ist Folgendes zu beachten:

1. Verbinden Sie den IV-รœberlaufschlauch (im rechten Arm des Simulators) mit einem Auffangbehรคlter (z. B. einem Infusionsbeutel).

2. Lassen Sie wรคhrend der Simulation รผberschรผssige Flรผssigkeit in einen Behรคlter flieรŸen.

Reinigen des IV-Arms Reinigen Sie den IV-Arm nach jeder Sitzung bzw. nach jedem Arbeitstag, indem Sie ihn mit einer Lรถsung mit 60 % Isopropanol oder 70 % Ethanol spรผlen.

Installieren der Adapterplatten fรผr die Defibrillation Der Torso des Simulators ist mit zwei Steckverbindern fรผr die Defibrillatorkabel ausgestattet. Schrauben Sie vor der Defibrillation die Defibrillatorsteckverbinder ab und entfernen Sie sie.

Der Simulator wird mit zwei Adapterplatten fรผr den Defibrillator geliefert. Die Defibrillator-Adapterplatten mรผssen angebracht werden, bevor ein Defibrillator mit Defibrillationskontakten (Paddles) verwendet werden kann. Schrauben Sie die Adapterplatten fest.

Wรคhrend der Defibrillation Fรผr SimJunior kann ein konventioneller Defibrillator (nicht mitgeliefert) verwendet werden. Wรคhrend einer stromfรผhrenden Defibrillation besteht das Risiko von Stromschlรคgen sowohl durch den Simulator als auch durch den Defibrillator. Wird fรผr den Simulator ein Defibrillator eingesetzt, sind sรคmtliche standardmรครŸigen Sicherheitsvorkehrungen zu treffen.

Vorsicht: Der Simulator darf wรคhrend der Defibrillation nicht mit elektrisch leitfรคhigen Oberflรคchen oder Gegenstรคnden in Berรผhrung kommen.

Warnhinweise:

โ€“ Die Defibrillation darf nur รผber die Defibrillator-Anschlรผsse erfolgen.

โ€“ Defibrillieren Sie den Simulator nicht, wenn die Haut nicht richtig platziert ist.

Anschluss der Blutdruckmanschette

Das Trainingsmodell ist mit einer individuell angepassten Blutdruckmanschette ausgestattet. Verbinden Sie den Schlauch vor Gebrauch mit dem weiรŸen Blutdruckanschluss auf der Rรผckseite der Link Box.

Hinweis: Der Lautsprecher fรผr den Blutdruck des Trainingsmodells befindet sich in der linken Ellenbogen-Beuge (unten eingekreist). Der Radialpuls und der Brachialpuls befinden sich in den rechteckig markierten Bereichen.

Kalibirieren der Blutdruckmanschette in LLEAP

1. Wรคhlen Sie im Menรผ die Option <Tools>.

2. Wรคhlen Sie รผber das Tools-Menรผ <Simulatoreinrichtung>.

3. Wรคhlen Sie im Untermenรผ die Option <Blutdruck kalibrieren>.

4. Folgen Sie den Anweisungen des Bildschirmassistenten, um die Kalibrierung durchzufรผhren.

Kalibrieren der Blutdruckmanschette im SimPad

1. Wรคhlen Sie im Menรผ die Option <Kalibrieren>.

2. Wรคhlen Sie im Dropdown-Menรผ die Option <Blutdruck kalibrieren>.

3. Folgen Sie die Anweisungen des Bildschirmassistenten, um die Kalibrierung durchzufรผhren.

Page 57: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

55

Sim

ulat

orei

nric

htun

g

War

tung

Er

satz

teile

und

Z

ubeh

รถrTe

chni

sche

Dat

en

Einf

รผhru

ng

Fehl

erbe

hebu

ng

Sim

ulat

ions

soft

war

e

Simulationssoftware

Auswechseln der Pupillen

SimJunior wird mit normalen Pupillen geliefert, die in die Augen eingesetzt sind. Ein zusรคtzlicher Satz mit Pupilleneinsรคtzen aus Kunststoff (verengt und erweitert) wird ebenfalls mit dem SimJunior geliefert.

Wechseln der Pupillen:

1. ร–ffnen Sie vorsichtig die Augenlider und achten Sie darauf, dass die Gesichtshaut des Simulators nicht einreiรŸt.

2. Mit dem mitgelieferten Saugwerkzeug oder mit dem Fingernagel kรถnnen Sie die Pupille vorsichtig aus dem Auge entfernen.

3. Ersetzen Sie die Pupille unter Verwendung des Saugwerkzeugs oder durch vorsichtiges Andrรผcken durch den gewรผnschten Einsatz.

Verwendung eines externen Kompressors Der externe Kompressor wird an den durchsichtigen Schlauch im Kabelverbund angeschlossen, der aus der rechten Seite des Simulators herausragt. Bei Verwendung eines externen Kompressors kรถnnen Sie den internen Kompressor รผber das SimPad oder LLEAP ausschalten.

Fรผr weitere Informationen zu externen Kompressoren und mit SimJunior kompatiblen Regulatorplatten wenden Sie sich bitte an Ihre Laerdal Vertretung vor Ort.

Ein- bzw. Ausschalten des interen Kompressors im SimPad

1. Starten Sie den <Manuellen Modus>, wรคhlen Sie ein Lernfeld und starten Sie die Sitzung.

2. Wรคhlen Sie in der unteren Menรผleiste die Option <Verschiedenes>.

3. Wรคhlen Sie im Untermenรผ die Option <Kompressor>.

4. Fรผhren Sie die gewรผnschten ร„nderungen durch und klicken Sie auf OK.

Ein- bzw. Ausschalten des interen Kompressors in LLEAP

1. Wรคhlen Sie im Menรผ die Option <Tools>.

2. Wรคhlen Sie รผber das Tools-Menรผ <Simulatoreinrichtung>.

3. Wรคhlen Sie im Untermenรผ die Option <Interner Kompressor>.

4. Fรผhren Sie die gewรผnschten ร„nderungen durch und klicken Sie auf OK.

Page 58: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

56

Hinweis: Fรผr Informationen รผber Ersatzteile siehe Abschnitt: Ersatzteile und Zubehรถr.

Vor Lagerung oder Versand

โ€“ Spรผlen Sie den IV-Arm mit einer Lรถsung aus 60 % Isopropanol oder 70 % Ethanol. ร–ffnen Sie das Abflussventil unten am rechten SimulatorfuรŸ.

Wartung

Wartung nach jeder Simulationssitzung Folgende PrรคventivmaรŸnahmen sind erfoderlich, um die Langlebigkeit des SimJunior-Simulators zu gewรคhrleisten.

โ€“ Schalten Sie das SimPad, die Link Box und die PCs aus

โ€“ Laden Sie gegebenenfalls die Akkus auf

โ€“ Spรผlen Sie das IV-Armsystem und lassen Sie das IO-Bein abtropfen (lassen Sie die Stรถpselรถffnung am unteren Ende des IO-Beins offen)

โ€“ Nach jeder Sitzung, in der der IV-Arm benutzt wurde, muss dieser mit einer Lรถsung aus 60 % Isopropanol oder 70 % Ethanol gespรผlt werden

โ€“ Wischen Sie die Haut mit einem feuchten Tuch ab

โ€“ Entfernen Sie nasse Bekleidung oder Laken

โ€“ Entfernen Sie Klebstoffreste mit einem feuchten Tuch oder Reinigungsalkohol

โ€“ Wechseln Sie je nach Gebrauch des Simulators verbrauchte und beschรคdigte Module aus

โ€“ Wechseln Sie Kabel und Anschlรผsse aus, die sichtbar beschรคdigt sind

โ€“ In regelmรครŸigen Abstรคnden sollte eine professionelle Wartung durch qualifiziertes Personal durchgefรผhrt werden

Eine Wartung ist in folgenden Fรคllen stets durchzufรผhren:

โ€“ Falls Flรผssigkeiten in oder auf dem Simulator verschรผttet wurden

โ€“ Nach Gebrauch in einer staubigen Umgebung

Page 59: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

57

Sim

ulat

orei

nric

htun

g

War

tung

Er

satz

teile

und

Z

ubeh

รถrTe

chni

sche

Dat

en

Einf

รผhru

ng

Sim

ulat

ions

soft

war

eFe

hler

behe

bung

Wartung

ร–ffnen des Torsos

ร–ffnen Sie fรผr folgende Vorgรคnge den Torso des Simulators: โ€“ Anbringen und Ersetzen von GliedmaรŸen โ€“ Auswechseln des Simulator-Akkus โ€“ Auswechseln der Blase fรผr die Brustkorbhebung und der

Lungenblase โ€“ Auswechseln der Torsohaut โ€“ Zur allgemeinen Inspektion

Warnhinweis: ร–ffnen Sie den Torso von links nach rechts und lรถsen Sie vorsichtig die Haken, mit denen die Haut angebracht ist. Ziehen Sie die Torsohaut beim Abheben nicht zu stark an, da hierdurch die Brustkabel beschรคdigt werden kรถnnten.

1. Lรถsen Sie die Halter der Torsohaut an der linken Seite des Torsos und an beiden Schultern.

Auswechseln des Simulator-Akkus

1. ร–ffnen Sie den Torso des Simulators.

2. Ziehen Sie die Torsohaut zur rechten Seite.

3. Lรถsen Sie das Verbindungskabel zum Defibrillationskonnektor.

4. Entfernen Sie das Defibrillator-Verbindungskabel an der rechten Seite des Simulators unterhalb der Brust.

Hinweis: Trennen Sie NICHT die Schlรคuche und Kabel, die den Bauchschaumstoff mit dem Simulator verbinden.

5. Bringen Sie die Torsohaut wieder an, indem Sie die Schritte 1โ€“4 in umgekehrter Reihenfolge durchfรผhren.

2. Ziehen Sie den Akku aus dem Akkugurt.

3. Ziehen Sie den Akkuanschluss von innen aus dem Simulator hoch. Lรถsen Sie den Akkuanschluss.

4. Entnehmen Sie den Akku aus dem Simulator.

5. Setzen Sie den aufgeladenen Akku ein oder installieren Sie einen neuen von Laerdal zugelassenen SimJunior-Akku.

6. SchlieรŸen Sie den Akku am Simulator an.

7. Bringen Sie die Torsohaut wieder an.

Page 60: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

58

Wartung

Aufladen des Simulator-Akkus

Der Simulator-Akku lรคdt sich wรคhrend des Betriebs selbst auf. Falls nรถtig, lรคsst sich der Akku des Simulators รผber einen optionalen externen Netzadapter aufladen.

1. Schalten Sie den Simulator รผber die Link Box aus.

2. Entnehmen Sie den Akku aus dem Simulator.

3. SchlieรŸen Sie ein zulรคssiges externes Akkuladegerรคt (mit einem den รถrtlichen Bestimmungen entsprechenden Stromkabel) an der Unterseite des Simulator-Akkus an. Stecken Sie das Stromkabel des Ladegerรคts in eine Wandsteckdose.

4. Wenn der Akku aufgeladen ist, setzen Sie den Akku wieder in den Simulator ein.

Auswechseln der Blase fรผr die Brustkorbhebung Die Blase fรผr die Brustkorbhebung befindet sich am unteren Ende der Brustplatte, mittig unterhalb der Lungen.

1. ร–ffnen Sie die Torsohaut, um die Brustplatte freizulegen. Siehe unter ร–ffnen des Torsos.

2. Lรถsen Sie den durchsichtigen Schlauch von der Blase und nehmen Sie sie heraus. Weitere Einzelheiten siehe unter Auswechseln der Lungenblase

3. Lรถsen Sie den durchsichtigen Schlauch von der Blase fรผr die Brustkorbhebung.

4. Entsorgen Sie die alte Blase.

5. Setzen Sie die neue Blase ein.

6. SchlieรŸen Sie den Schlauch an die neue Blase an.

7. SchlieรŸen Sie den Torso und bringen Sie die Torsohaut wieder an.

Auswechseln der Lungenblase Bei undichten Stellen sollte die Lungenblase (in der Brusthรถhle) ausgewechselt werden.

1. ร–ffnen Sie die Torsohaut.

2. Lรถsen Sie den durchsichtigen Schlauch unterhalb der beiden Seiten der Lungenblase. Siehe Illustration zu Schritt 2 im Abschnitt Auswechseln der Blase fรผr die Brustkorbhebung.

3. Lรถsen Sie die Lungenblasenklemme oben in der Mitte.

4. Ziehen Sie den oberen Mittelteil der Lungenblase vom Sockel nach oben.

5. Um die neue Lungenblase einzusetzen, befolgen Sie die obigen Schritte in umgekehrter Reihenfolge.

Page 61: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

59

Sim

ulat

orei

nric

htun

g

War

tung

Er

satz

teile

und

Z

ubeh

รถrTe

chni

sche

Dat

en

Einf

รผhru

ng

Sim

ulat

ions

soft

war

eFe

hler

behe

bung

Ersetzen der Simulatorhaut Die Simulatorhaut muss eventuell ersetzt werden, wenn sie eingerissen, perforiert oder verfรคrbt ist.

Torsohaut:

Zum Ersetzen der Torsohaut des Simulators siehe ร–ffnen des Torsos.

Armhaut:

Armhaut des Simulators auswechseln:

1. Ziehen Sie die alte Haut des Simulators von oben nach unten รผber den Arm und die Hand, oder *schneiden Sie die Haut ab.

Anbringen eines neuen Arms:

Wartung

Auswechseln des rechten IV-Arms

1. ร–ffnen Sie den Torso; siehe Abschnitt ร–ffnen des Torsos.

2. Entfernen Sie den alten Arm, indem Sie den Bolzen abschrauben, mit dem der Arm an der Schulter des Simulators befestigt ist.

3. Vergewissern Sie sich, dass die Schraube lose genug ist, damit die Armachse leicht herausgleiten kann.

4. Entsorgen Sie den alten Arm entsprechend Ihrer lokalen Richtlinien.

1. Vergewissern Sie sich, dass die Schulterschraube lose genug ist, damit die Armachse leicht an den vorgesehenen Platz gleiten kann.

2. SchlieรŸen Sie den Arm an den entsprechenden Verbindungspunkten am Torso an.

3. Schieben Sie die Armachse vorsichtig so in die Schulterspange, dass die Achse eng an der Innenseite der Spange anliegt.

4. Ziehen Sie die Schraube mit einem Inbusschlรผssel an.

Auswechseln des rechten IO-Beins Befolgen Sie nachstehende Anweisungen, um den rechten Unterschenkel abzunehmen:

1. Vergewissern Sie sich, dass jegliche Flรผssigkeit aus dem Bein abgeflossen ist.

2. Entfernen Sie das alte IO-Bein, indem Sie den Bolzen abschrauben, mit dem es am Oberschenkel befestigt ist.

3. Schieben Sie den IO-Unterschenkel aus dem Oberschenkel heraus.

4. Entsorgen Sie das alte IO-Bein entsprechend Ihrer lokalen Richtlinien.

Fรผhren Sie die oben genannten Schritte in umgekehrter Reihenfolge durch, um das neue IO-Bein zu montieren.

Warnhinweis: *Achten Sie darauf, die Armkonstruktion nicht zu zerstechen oder zu zerschneiden.

2. Entsorgen Sie die alte Haut entsprechend Ihrer lokalen Richtlinien.

3. Befeuchten Sie die Innenseite der neuen Armhaut mit einem milden, mit Wasser verdรผnnten Flรผssigreiniger.

4. Befeuchten (oder beschรคumen) Sie die Armkonstruktion mit einer Mischung aus milder Flรผssigseife und Wasser.

5. Fรผhren Sie die Simulatorhand in die Haut ein.

6. Ziehen Sie die Haut wie bei einem Handschuh รผber die Finger.

7. Ziehen Sie die Haut weiter nach oben รผber die Armkonstruktion.

Page 62: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

60

Fehlerbehebung

Systemeinstellung

Problem

โ€ข Datenverlust oder totaler Systemausfall (allgemeiner Systemabsturz).

Mรถgliche Lรถsung

โ€ข Bei einem Systemausfall oder bei totalem Datenverlust oder Datenbeschรคdigung setzen Sie sich bitte mit Ihrem lokalen Laerdal Service Center in Verbindung.

LLEAPโ€ข Siehe die Software-Hilfedateien > LLEAP > Fehlersuche und

Fehlerbehebung (Hilfe รผber die Laerdal Simulation Home)

Laerdal Patient Monitorโ€ข Siehe die Software-Hilfedateien > Laerdal Patient Monitor >

Fehlerbehebung. (Hilfe รผber die Laerdal Simulation Home)

Debriefing- und Videoaufzeichnungโ€ข Siehe den Abschnitt รผber Fehlerbehebung in der Hilfe zu

SimView (Zugriff รผber einen Link am unteren Bildschirmrand in SimView) oder die Anleitung รผber Fehlerbehebung in der Session Viewer-Hilfe (Zugriff รผber die Laerdal Simulation Home)

Simulator

Problem

โ€ข Unvorhersehbares Verhalten.

Mรถgliche Lรถsungen

โ€ข Stรถrungen des Simulators kรถnnen durch lose Kabel, Schlรคuche oder Anschlรผsse verursacht werden. ร–ffnen Sie den Torso und prรผfen Sie, ob sich irgendwelche Komponenten gelรถst haben oder undicht geworden sind. Siehe Abschnitt: Einstellungen am Simulator โ€“ ร–ffnen des Torsos.

โ€ข Beim Austreten von Flรผssigkeit schalten Sie den Simulator aus und wenden Sie sich an den technischen Kundendienst von Laerdal.

Atemwegsverschmutzung

Problem

โ€ข Die Atemwege des Simulators wurden durch eine Mund-zu-Mund-Atemspende kontaminiert.

Mรถgliche Lรถsung

โ€ข Sรคubern Sie die AuรŸenseite des Simulators mit Laerdal- Reinigungstรผchern (Manikin Wipes). Reinigen Sie das Innere der Mundhรถhle mit den Laerdal- Reinigungstรผchern (Manikin Wipes). Wechseln Sie die Lungenblase aus; siehe Abschnitt Wartung โ€“ Auswechseln der Lungenblase.

Brustkorbbewegung

Problem

โ€ข Der Brustkorb des Simulators hebt sich nicht.

Mรถgliche Lรถsungen

โ€ข รœberprรผfen Sie, ob der Simulator eingeschaltet ist. โ€ข Vergewissern Sie sich รผber das SimPad oder LLEAP, dass โ€“ awRR nicht auf null gestellt ist โ€“ die Brustkorbhebung nicht ausgeschaltet ist โ€“ fรผr das EKG ein Perfusionsrhythmus eingestellt ist. โ€“ Es wurden keine Atemwegskomplikationen wie z. B. maximaler

Luftwiderstand oder Laryngospasmus eingestellt. โ€“ Vergewissern Sie sich, dass der integrierte Kompressor in

LLEAP aktiviert wurde. Siehe Abschnitt: Ausschalten des internen Kompressors.

โ€ข Vergewissern Sie sich, dass jede externe Druckluftquelle abgestellt wurde und die Luftleitung vom Simulator abgekoppelt ist.

โ€ข Der interne Kompressor kรถnnte sich รผberhitzen. Warten Sie etwa 20 Minuten, bis der Kompressor abkรผhlt.

โ€ข Die Brustkorbhebung ist auf beidseitig eingestellt (z. B. falls ein ET-Schlauch zu tief in die Bronchien eingefรผhrt wurde).

โ€ข Die Blase fรผr die Brustkorbhebung ist undicht, oder der Schlauch zur Blase fรผr die Brustkorbhebung ist geknickt oder hat sich gelรถst. Wechseln Sie die Blase fรผr die Brustkorbhebung aus, falls sie undicht ist; siehe Abschnitt Wartung: Auswechseln der Blase fรผr die Brustkorbhebung.

โ€ข Vergewissern Sie sich, dass die Luftschlรคuche keine undichten Stellen aufweisen; stellen Sie fest, ob alle Verbindungen und Anschlรผsse intakt sind. Wechseln Sie den Schlauchabschnitt aus, falls er undicht ist.

โ€ข Flache Brustkorbbewegungen und der interne Kompressor lรคuft ununterbrochen. Der interne Kompressor kรถnnte verschlissen sein. Wenden Sie sich an den technischen Kundendienst von Laerdal.

Lungen

Problem

โ€ข Lungen funktionieren nicht ordnungsgemรครŸ

Mรถgliche Lรถsungen

โ€ข ร–ffnen Sie den Torso und die Brustplatte. รœberprรผfen Sie, ob sich die Lungen frei ausdehnen kรถnnen und nicht durch irgendwelche Kabel behindert sind.

โ€ข รœberprรผfen Sie, ob die Lungenblase ordnungsgemรครŸ angeschlossen ist und sich die Schlรคuche nicht verdreht haben.

โ€ข รœberprรผfen Sie, ob sich die Lungenblase in horizontaler Position befindet und ordnungsgemรครŸ eingefรผhrt wurde.

Page 63: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

61

Sim

ulat

ions

soft

war

eSi

mul

ator

einr

icht

ung

W

artu

ng

Ersa

tzte

ile u

nd

Zub

ehรถr

Tech

nisc

he D

aten

Ei

nfรผh

rung

Fe

hler

behe

bung

Fehlerbehebung

โ€ข Untersuchen Sie die Lungenblase auf Defekte oder Risse.

โ€ข Vergewissern Sie sich, dass im Simulator keine Atemwegsblockaden vorliegen, die den Luftstrom behindern.

โ€ข Falls trotz Neueinstellung der Lungencompliance / -resistance keine ร„nderung eintritt, wenden Sie sich an den technischen Kundendienst von Laerdal.

โ€ข Falls keine ร„nderung beim Lungenwiderstand eintritt, wenden Sie sich an den technischen Kundendienst von Laerdal.

Mechanisches Gerรคusch wรคhrend der AuskultationKlicken Sie in LLEAP auf <Auskultationsfokus>.

Puls (radial und brachial)

Problem

โ€ข Puls ist nicht tastbar

Mรถgliche Lรถsungen

โ€ข Die Haut liegt mรถglicherweise zu eng รผber den Pulseinheiten โ€“ passen Sie die Haut neu an und starten Sie das System dann neu.

โ€ข Vergewissern Sie sich, dass der Blutdruck einen systolischen Mindestwert von 60 mmHg hat.

โ€ข Vergewissern Sie sich, dass der Kompressor eingeschaltet ist.

Hinweis: Bei einem Radialispulswert unter 60 mmHg kann der periphere Puls ganz verschwinden.

Herunterfahren des Simulators

Problem

โ€ข Der Simulator reagiert nicht.

Lรถsung

1. Schalten Sie die Link Box aus.

2. Schalten Sie das SimPad bzw. bei Verwendung von LLEAP den Ausbilder-PC aus.

3. Starten Sie das System neu.

Falls der Simulator noch immer nicht reagiert, wenden Sie sich an Ihren Laerdal-Vertreter.

Page 64: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

62

Hinweise

Page 65: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

63

Sim

ulat

orei

nric

htun

g

War

tung

Er

satz

teile

und

Z

ubeh

รถrTe

chni

sche

Dat

en

Einf

รผhru

ng

Sim

ulat

ions

soft

war

eFe

hler

behe

bung

Technische Daten

GesamtmaรŸe Lรคnge/Breite (nur Simulator): 120 cm x 42,5 cm Gewicht (nur Simulator): 11,36 kg

Stromversorgung des Simulators Externe Stromzufuhr : Eingangsspannung 9 VDC, 1,5 A Interner Akku: 7,4 V, 4,4 Ah, Lithium-Ionen

Verwenden Sie fรผr SimJunior ausschlieรŸlich zugelassene externe Stromquellen und Akkus.

Luftdruck Integrierter Lufttank: Max. 6 psi (0,4 bar) Externe Druckluftverbindung: Max. 16 psi (1,1 bar)

Temperaturgrenzen Betriebstemperaturen: +4 ยบC bis 40 ยบC Lagerungstemperaturen: โ€“15 ยบC bis 50 ยบC

Umgebung โ€“ nur Simulator Relative Luftfeuchtigkeit: 20 %โ€“90 % (nicht kondensierend) NICHT bei Nรคsse im Freien verwenden. Nicht mit Salzsprรผhnebel getestet.

RF-Kommunikation Betriebsreichweite: Max. 10 m

Materialliste fรผr den Simulator Bekleidung: Baumwolle, Nylon Haut und Atemwege: PVC Hartes Kunststoffmaterial auรŸen: PVC, ABS Kunststoff innen: Silikon, TPU, PVC, Nitril ABS, POM, Nylon + GF Epoxid-Polyurethan Metallkomponenten: Aluminium, Messing, Stahl

Mindestsystemanforderungen

โ€ข Intel i-Core 3. Generation oder neuer

โ€ข CPU PassMark Wert รผber 3000

โ€ข 4 GB RAM

โ€ข 120 GB freier Festplattenspeicher

โ€ข 1366 x 768 oder besser

โ€ข Headset mit Mikrofon

โ€ข USB-Ports โ€“ 2

Mindestanforderungen an die Software

โ€ข Windows 7 oder Windows 8

โ€ข 100 % DPI

Reinigungsflรผssigkeiten Zur Reinigung des Simulators wird empfohlen:

โ€“ 60 % Isopropanol-Alkohol

โ€“ 70 % Ethanol

โ€“ Eine milde Lรถsung aus Flรผssigseife und Wasser

IV-Flรผssigkeit Verwenden Sie zur Simulation von IV- und IO-Flรผssigkeiten ausschlieรŸlich destilliertes oder deionisiertes Wasser.

Page 66: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

64

Hinweise

Page 67: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

65

Sim

ulat

orei

nric

htun

g

War

tung

Er

satz

teile

und

Z

ubeh

รถrTe

chni

sche

Dat

en

Einf

รผhru

ng

Sim

ulat

ions

soft

war

eFe

hler

behe

bung

Ersatzteile und Zubehรถr

Ersatzteile und Zubehรถr Eine aktuelle Liste der Ersatzteile und des Zubehรถrs finden Sie unter www.laerdal.com.

Page 68: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

66

Hinweise

Page 69: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

67

Mantenimiento 78

โ€“ Mantenimiento despuรฉs de cada sesiรณn de simulaciรณn 78 โ€“ Cรณmo abrir el torso 79 โ€“ Cรณmo reemplazar la baterรญa del simulador 79 โ€“ Carga de la baterรญa del simulador 80 โ€“ Cรณmo reemplazar la almohadilla de elevaciรณn del tรณrax 80 โ€“ Cรณmo reemplazar la almohadilla del pulmรณn 80โ€“ Cรณmo reemplazar las pieles del simulador 81 โ€“ Cรณmo reemplazar el brazo derecho para tratamiento

intravenoso derecho 81 โ€“ Cรณmo reemplazar la pierna derecha para

tratamiento intraรณseo 81

Resoluciรณn de problemas 82

Introducciรณn 68

โ€“ Informaciรณn reglamentaria 68โ€“ Cuidado general del simulador 69โ€“ Imagen general de SimJunior 71 โ€“ Caracterรญsticas de SimJunior 72

Configuraciรณn del simulador 75

โ€“ Cรณmo prepararse para las simulaciones 75 โ€“ Preparaciรณn de la pierna para tratamiento intraรณseo 75 โ€“ Administraciรณn de fluidos para tratamiento intravenoso 75 โ€“ Drenaje del exceso de fluidos para

tratamiento intravenoso 76 โ€“ Limpieza del brazo para tratamiento intravenoso 76 โ€“ Instalaciรณn de placas adaptadoras para desfibrilaciรณn 76 โ€“ Conexiรณn del manguito del esfigmomanรณmetro 76 โ€“ Calibraciรณn del manguito para medir la presiรณn

arterial en LLEAP 76 โ€“ Calibraciรณn del manguito para medir la presiรณn

arterial en SimPad 76โ€“ Cambiar las pupilas 77 โ€“ Uso de un compresor externo 77

Especificaciones 85

Software de simulaciรณn 74

โ€“ PC del instructor 74 โ€“ Licencia del software 74 โ€“ Laerdal Simulation Home 74โ€“ LLEAP 74โ€“ Voice Conference Application 74โ€“ Patient Monitor 74โ€“ Session Viewer y SimView Server 74โ€“ Otras aplicaciones 74โ€“ SimDesigner 74โ€“ Archivos de ayuda 74โ€“ Descargas por Internet 74

Piezas de repuesto y accesorios 87

รndice ES

Page 70: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

68

Li-ion

Introducciรณn

Introducciรณn al simulador SimJuniorโ„ข SimJunior es un simulador de un paciente pediรกtrico de tamaรฑo real, diseรฑado por Laerdal en colaboraciรณn con la Academia Americana de Pediatrรญa. SimJunior se puede utilizar para la educaciรณn de individuos o equipos de profesionales sanitarios de diversas disciplinas mรฉdicas.

El simulador SimJunior viene completamente ensamblado. No se necesita ensamblar las piezas del simulador.

Para obtener detalles sobre la preparaciรณn de SimJunior para la simulaciรณn, consulte la secciรณn โ€œConfiguraciรณn del simuladorโ€.

Ayuda de SimJunior Instrucciones de uso

Instrucciones e ilustraciones paso a paso para utilizar el simulador SimJunior.

Manuales de usuario del fabricante original

Se deben seguir todos los manuales de usuario y el etiquetado de los fabricantes originales. Las instrucciones de uso de SimJunior no reemplazan ni sustituyen las instrucciones del fabricante original.

Guรญa de configuraciรณn rรกpida de SimJunior

Guรญa paso a paso para la configuraciรณn del sistema de simulaciรณn de SimJunior.

Instrucciones de uso (DFU) de SimPad

Las instrucciones de uso de SimPad proporcionan instrucciones para utilizar el Link Box y el SimPad con SimJunior.

Archivos de ayuda de LLEAP (Laerdal Learning Application)

Los archivos de ayuda de LLEAP se encuentran accesibles en Laerdal Simulation Home, consulte Laerdal Simulation Home.

Entre los temas de ayuda se incluyen:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

Asistencia tรฉcnica

Para obtener asistencia tรฉcnica, pรณngase en contacto con el centro de servicio tรฉcnico local de Laerdal.

Descargas por Internet

Visite www.laerdal.com/downloads para descargar las รบltimas instrucciones de uso y el รบltimo software de simulaciรณn.

Contenido de SimCenter SimCenter ofrece un acceso sencillo a contenido validado por expertos en simulaciรณn de todo el mundo para que pueda aprovechar su experiencia y sacar el mรกximo partido de cada oportunidad de formaciรณn. Encontrarรก una amplia gama de escenarios que se han desarrollado especรญficamente para el SimJunior. Visite www.mysimcenter.com para conocer cรณmo puede optimizar al mรกximo su experiencia de formaciรณn.

Informaciรณn reglamentaria

Federal Communications Commission Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Precauciรณn Los cambios o las modificaciones no aprobados expresamente por la parte responsable del cumplimiento podrรญan anular la facultad del usuario para operar el equipo.

Las baterรญas de iones de litio deben reciclarse.

Por el presente documento, Laerdal Medical AS declara que, cuando este producto lleva la marca CE, cumple con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.

Deseche este producto de acuerdo con los requisitos y las reglamentaciones locales.

Page 71: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

si

mul

aciรณ

n C

onfig

urac

iรณn

del s

imul

ador

Man

teni

mie

nto

Piez

as d

e re

pues

to

y ac

ceso

rios

Es

peci

ficac

ione

s

Intr

oduc

ciรณn

R

esol

uciรณ

n de

pr

oble

mas

69

Introducciรณn

Cuidado general del simulador Siga las instrucciones que se encuentran a continuaciรณn para mantener el rendimiento y la longevidad รณptimos del simulador y sus componentes.

Cuidado general

Para mantener la piel del simulador, lรกvese las manos antes del uso y coloque el simulador en una superficie limpia. Laerdal recomienda:

โ€“ Utilizar guantes durante los escenarios de simulaciรณn. Evitar el uso de guantes plรกsticos de color, ya que pueden provocar un cambio de color de la piel del simulador.

โ€“ No utilice marcadores con punta de fieltro, plumas de tinta, acetona, yodo ni otros medicamentos que manchen cerca del simulador. Tenga cuidado de no colocar el simulador sobre papel de periรณdico o de color. Las manchas pueden ser permanentes.

โ€“ Lave la piel del simulador con agua y jabรณn suave.

No intente realizar las siguientes tรฉcnicas en este simulador debido a la incapacidad de desinfectar adecuadamente la vรญa aรฉrea:

โ€“ Ventilaciรณn boca a boca/boca-mascarilla. โ€“ Inserciรณn de vรณmito o lรญquidos simulados para succionar.

โ€“ Si una sesiรณn de capacitaciรณn involucra el uso de lรญquidos en el brazo para tratamiento intravenoso, drene el brazo inmediatamente despuรฉs de la sesiรณn de capacitaciรณn.

โ€“ Utilice รบnicamente lubricante para vรญa aรฉrea de Laerdal y aplรญquelo en pequeรฑas cantidades.

โ€“ Enjuague, limpie y seque los mรณdulos de los componentes del simulador.

โ€“ Pliegue la piel del torso hacia atrรกs y coloque talco en el interior de la piel del torso para disminuir la fricciรณn. No vuelque talco en la cavidad torรกcica del simulador.

Ambiente En condiciones de frรญo, espere hasta que el simulador haya alcanzado la temperatura ambiente antes de encenderlo.

Para evitar el sobrecalentamiento y reducir el desgaste:

โ€“ Al utilizarlo a temperaturas superiores a 40 ยฐC, permita siempre que el simulador se enfrรญe entre las sesiones de entrenamiento.

โ€“ Al utilizarlo en una cama, el simulador no debe cubrirse con ropa de cama gruesa que impida el traspaso de calor del simulador.

Manejo general del simulador Tome las siguientes precauciones para evitar lesiones personales o daรฑos en el producto:

โ€“ Introduzca los lรญquidos en el simulador รบnicamente como se indica en este documento.

โ€“ Lubrique la vรญa aรฉrea oral y nasal con el lubricante proporcionado antes de insertar cualquier instrumento, tubo o dispositivo para vรญa aรฉrea. Ademรกs, lubrique los instrumentos y los tubos antes del uso.

โ€“ No introduzca aire humidificado en el sistema durante la ventilaciรณn.

โ€“ No utilice el simulador si las cรกnulas y el cableado internos estรกn desconectados.

โ€“ No utilice nunca el simulador SimJunior al aire libre en condiciones de humedad, ya que puede constituir un riesgo de descargas o daรฑar el simulador.

โ€“ Es posible que utilizar un desfibrilador a temperaturas superiores a 35 ยฐC provoque sobrecalentamiento.

Advertencia: No utilice mรกquinas automatizadas de compresiรณn del tรณrax en el simulador.

Precauciรณn con respecto al lรกtex: Este producto contiene lรกtex de caucho natural, que puede provocar reacciones alรฉrgicas en humanos al contacto con la piel.

Peligros de desfibrilaciรณn SimJunior permite la desfibrilaciรณn.

Se puede utilizar un desfibrilador convencional en SimJunior. Durante la desfibrilaciรณn, el desfibrilador y el simulador pueden presentar un riesgo de descarga. Se deben tomar todas las precauciones de seguridad estรกndar al utilizar un desfibrilador en el simulador.

โ€ข Lea y siga todas las instrucciones de seguridad y funcionamiento suministradas con el desfibrilador y con el equipo necesario para su uso.

โ€ข Al desfibrilar, siga el protocolo de desfibrilaciรณn evitando el contacto entre las palas externas y cualquiera de los sitios en que se encuentran los electrodos. Se puede aplicar una descarga mรกxima de 300 julios.

โ€ข No seguir las medidas de seguridad podrรญa provocar lesiones o la muerte.

Para obtener mรกs informaciรณn, consulte el manual del usuario original del desfibrilador.

Advertencias:

โ€“ Al realizar la desfibrilaciรณn, utilice los conectores del desfibrilador o la placa intercambiable montada en el tรณrax del simulador. No utilice los conectores para ECG, que estรกn diseรฑados exclusivamente para la monitorizaciรณn de ECG. La desfibrilaciรณn en los conectores de ECG daรฑarรก los circuitos internos del simulador y puede provocar lesiones personales.

โ€“ No desfibrile el simulador cuando estรฉ apagado o si no estรก funcionando con normalidad.

Exenciรณn de responsabilidad El uso del sistema de simulaciรณn de pacientes de SimJunior para la formaciรณn del personal se debe llevar a cabo bajo la supervisiรณn de personal tรฉcnico o profesionales mรฉdicos adecuadamente formados, que comprendan los principios educativos y los protocolos mรฉdicos reconocidos. Como con todos los simuladores y otros dispositivos de formaciรณn, es posible que haya aproximaciones, variaciones e imprecisiones en las caracterรญsticas anatรณmicas y el modelado fisiolรณgico. Por este motivo, Laerdal no garantiza que todas las caracterรญsticas sean completamente precisas.

Garantรญa global Consulte el folleto de garantรญa global de Laerdal o visite www.laerdal.com.

Paรญs de origen: SimJunior se fabrica en EE. UU.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 72: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

70

Introducciรณn

Para evitar el sobrecalentamiento durante la desfibrilaciรณn, no exceda una secuencia de desfibrilaciรณn de 3 choques en 45 segundos, seguida de 1 minuto de reanimaciรณn cardiopulmonar (RCP). Despuรฉs de 30 minutos, suspenda todos los choques durante al menos 15 minutos antes de comenzar una nueva secuencia. No repita esto durante un perรญodo de mรกs de 4 horas. Ademรกs, no proporcione mรกs de 2 descargas x 300 J por minuto.

Advertencias:

โ€“ El simulador no debe entrar en contacto con superficies ni objetos conductores de electricidad durante la desfibrilaciรณn.

โ€“ Evite el uso en todos los ambientes inflamables. Por ejemplo, durante la desfibrilaciรณn, se deben evitar niveles altos de oxรญgeno puro. Asegรบrese de que haya una buena ventilaciรณn si se utiliza oxรญgeno concentrado cerca del simulador.

โ€“ El torso del simulador siempre se debe mantener seco.

โ€“ Permita que el simulador se aclimate antes de desfibrilar. Los cambios repentinos de temperatura pueden provocar que se acumule condensaciรณn en los componentes elรฉctricos, lo que podrรญa constituir un riesgo de choque.

โ€“ Para evitar las marcas por los electrodos en la piel del torso, no aplique gel conductor o almohadillas conductoras de desfibrilaciรณn diseรฑadas para el uso en los pacientes.

โ€“ Presionar demasiado los conectores de desfibrilaciรณn durante la desfibrilaciรณn tambiรฉn puede provocar chispazos y marcas.

โ€“ No desfibrile el simulador si la piel del torso no estรก colocada.

Riesgos mecรกnicos o elรฉctricos No utilice el simulador SimJunior si:

โ€“ Los miembros no estรกn unidos al torso

โ€“ La piel estรก desgarrada o ajustada en forma inadecuada

โ€“ Los cables, tubos o conectores externos o internos estรกn daรฑados

โ€“ Hay pรฉrdida de lรญquidos en el simulador o sobre รฉl

โ€“ Hay sonidos inusuales que indican pรฉrdida de aire o daรฑo mecรกnico

โ€“ Hay signos de desperfectos elรฉctricos, como un simulador que no responde a los estรญmulos, olor o humo inusuales

Advertencia:

โ€“ Evite los riesgos de pinzamiento: no utilice el simulador sin la piel externa

Uso de la baterรญa y mantenimiento

โ€“ Se deben utilizar siempre baterรญas aprobadas para el funcionamiento del SimJunior, Link Box y SimPad.

โ€“ Asegรบrese de que las baterรญas estรฉn instaladas de forma adecuada. Insertar y conectar las baterรญas de forma incorrecta podrรญa provocar un cortocircuito.

Advertencias:

โ€“ Deseche las baterรญas de acuerdo con la normativa local.

โ€“ El cargador de baterรญa externo estรก diseรฑado solamente para uso en interiores.

โ€“ La baterรญa del simulador solo debe cargarse a temperaturas que varรญen entre 0 ยฐC y 40 ยฐC.

โ€“ No maltrate, desarme ni intente reparar la baterรญa. No utilice las baterรญas si estรกn visiblemente daรฑadas, tienen un desperfecto o parecen tener pรฉrdidas.

โ€“ Tenga extremo cuidado para evitar el contacto directo con las piezas elรฉctricas, calientes o de las que sale humo. En el caso de que una baterรญa tenga pรฉrdidas, desconecte y retire la baterรญa cuando se considere que es seguro hacerlo.

โ€“ La exposiciรณn a lรญquidos constituye un riesgo de explosiรณn.

โ€“ Cada 30 ciclos de carga, drene la baterรญa por completo antes de recargar de nuevo. Para vaciar la baterรญa, haga funcionar al simulador con alimentaciรณn por baterรญa hasta que se apague automรกticamente.

โ€“ Reemplace รบnicamente por una baterรญa de Laerdal para SimJunior.

Almacenamiento y transporte

โ€“ No guarde nunca baterรญas totalmente cargadas durante mรกs de un mes.

โ€“ La baterรญa del simulador se puede transportar en el simulador durante el transporte por aire.

โ€“ Cuando transporte las baterรญas de repuesto, pรณngase en contacto con la aerolรญnea o la compaรฑรญa de transporte para obtener informaciรณn sobre las รบltimas reglamentaciones en cuanto al transporte.

Advertencia:

โ€“ El simulador SimJunior y sus accesorios son pesados cuando se los combina en el estuche para transporte. Asegรบrese siempre de que el simulador SimJunior estรฉ firmemente fijado durante el transporte y el almacenamiento para evitar lesiones personales o daรฑos en el producto.

Page 73: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

si

mul

aciรณ

n C

onfig

urac

iรณn

del s

imul

ador

Man

teni

mie

nto

Piez

as d

e re

pues

to

y ac

ceso

rios

Es

peci

ficac

ione

s

Intr

oduc

ciรณn

R

esol

uciรณ

n de

pr

oble

mas

71

Pierna para tratamiento intraรณseo

Puerto de llenado de la pierna para tratamiento

intraรณseo

Simulador SimJunior

Conector de ECG para el brazo derecho

Placa para desfibrilaciรณn del esternรณn

Brazo para tratamiento intravenoso

Conector de ECG para la pierna derecha

Cable de alimentaciรณn

Conexiรณn de aire externa

Cable de simulador (60 pins)

Introducciรณn

Conector de ECG para el brazo izquierdo

Brazo para medir la presiรณn arterial

Placa para desfibrilaciรณn del apex

Conector de ECG para la pierna izquierda

Page 74: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

72

Introducciรณn

Simulador SimJunior SimJunior facilita el aprendizaje interactivo de habilidades para salvar vidas y responde a la intervenciรณn clรญnica mediante el control del instructor y/o escenarios preprogramados para una prรกctica eficaz del diagnรณstico y el tratamiento de un paciente.

Con respiraciรณn espontรกnea, control de la vรญa aรฉrea, voz, sonido, ECG y otras caracterรญsticas clรญnicas, SimJunior es un simulador pediรกtrico totalmente funcional. SimJunior permite la observaciรณn y el reconocimiento de la mayorรญa de las constantes vitales, lo que permite al instructor evaluar las habilidades del alumno en funciรณn de una situaciรณn clรญnica realista.

Caracterรญsticas de SimJunior

โ€“ Vรญa aรฉrea realista para la simulaciรณn de un manejo difรญcil de la vรญa aรฉrea y de intubaciones orales y nasales

โ€“ Respiraciรณn perceptible

โ€“ Caracterรญsticas cardiacas, incluidas la desfibrilaciรณn y la cardioversiรณn

โ€“ Ojos con pupilas intercambiables (normales, dilatadas o en punto)

โ€“ Convulsiones para simular crisis convulsivas

โ€“ Compresiones torรกcicas

โ€“ Acceso vascular

โ€“ Sonidos del corazรณn, de respiraciรณn y de los intestinos normales y anormales

โ€“ Control de simulaciones automรกticas en funciรณn de escenarios de pacientes programados previamente y validados

Las simulaciones se pueden ejecutar de forma autรณnoma utilizando escenarios en el SimPad o con LLEAP (PC). El desarrollo de la condiciรณn del paciente estรก preprogramado y responde automรกticamente de acuerdo con las intervenciones del participante.

Dimensiones generales

Longitud/anchura (solo simulador): 120 cm x 42,5 cm Peso (solo simulador): 11,36 kg

Ropa de SimJunior

SimJunior viene con ropa diseรฑada a medida con aberturas de Velcro para que se pueda retirar fรกcilmente. Las instrucciones de lavado se encuentran en la etiqueta de la ropa.

โ€“ Camisa

โ€“ Pantalรณn corto

โ€“ Calzoncillo

Caracterรญsticas clรญnicas generales Caracterรญsticas de la vรญa aรฉrea

La vรญa aรฉrea es anatรณmicamente correcta hasta la trรกquea. La vรญa aรฉrea puede ser manipulada mediante:

โ€“ Inclinaciรณn de la cabeza/elevaciรณn del mentรณn

โ€“ Tracciรณn mandibular con mandรญbula articulada

โ€“ Presiรณn cricoidea y manipulaciรณn

โ€“ Aspiraciรณn (oral y nasofarรญngea).

Se puede hacer respirar al simulador mediante mรฉtodos normales y de emergencia:

โ€“ Ventilaciรณn con balรณn resucitador y mascarilla.

โ€“ Intubaciรณn orotraqueal

โ€“ Intubaciรณn nasotraqueal

Antes de utilizar dispositivos para la vรญa aรฉrea, lubrique con el lubricante para vรญa aรฉrea de Laerdal.

El siguiente equipo o los siguientes mรฉtodos son adecuados para asegurar la vรญa aรฉrea del simulador:

โ€“ Mascarilla larรญngea (tamaรฑo 2,5)

โ€“ Intubaciรณn con tubo endotraqueal (identificaciรณn del tamaรฑo: 4,5 con globo, 5,5 sin globo)

Se recomienda la utilizaciรณn de un estilete maleable. Asegรบrese de que no se extienda mรกs allรก del tubo endotraqueal (ET).

Las siguientes condiciones del simulador indican la colocaciรณn incorrecta del tubo:

โ€“ Intubaciรณn del bronquio principal derecho; elevaciรณn unilateral del tรณrax

โ€“ Distensiรณn estomacal

โ€“ Ausencia de sonidos en el tรณrax (consulte la secciรณn Respiraciรณn)

Las caracterรญsticas del simulador se pueden configurar para presentar diversos escenarios con respecto a la vรญa aรฉrea:

โ€“ Edema de lengua: nivel normal, medio y mรกximo

โ€“ Apertura o cierre de los pulmones

Caracterรญsticas de la respiraciรณn

SimJunior puede simular una respiraciรณn espontรกnea con elevaciรณn y descenso visibles del tรณrax y frecuencia respiratoria variable. La respiraciรณn se genera mediante un compresor de aire que se encuentra en el muslo derecho del simulador.

โ€“ Elevaciรณn y descenso bilaterales del tรณrax con respiraciรณn espontรกnea

โ€“ Elevaciรณn y descenso unilaterales del tรณrax con intubaciรณn del bronquio principal derecho durante las ventilaciones

โ€“ Sonidos unilaterales y bilaterales del pulmรณn

โ€“ Sonidos pulmonares normales y anรณmalos

โ€“ Frecuencia de respiraciรณn variable (0 a 60 respiraciones por minuto)

โ€“ Sitios de auscultaciรณn anterior (4)

Es posible cerrar solo el pulmรณn izquierdo o el derecho o los dos a la vez para crear una obstrucciรณn parcial o completa de la vรญa aรฉrea. El simulador SimJunior tambiรฉn se puede utilizar con ventilaciรณn asistida.

Nota: Los pulmones no estรกn diseรฑados para ser utilizados con vรกlvulas de presiรณn positiva al final de la espiraciรณn (Positive end-expiratory pressure, PEEP).

Page 75: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

si

mul

aciรณ

n C

onfig

urac

iรณn

del s

imul

ador

Man

teni

mie

nto

Piez

as d

e re

pues

to

y ac

ceso

rios

Es

peci

ficac

ione

s

Intr

oduc

ciรณn

R

esol

uciรณ

n de

pr

oble

mas

73

Introducciรณn

Caracterรญsticas circulatorias

Cardiaco:

โ€“ Biblioteca extensa de ECG; pulsos desde 0 hasta 200.

โ€“ Sonidos del corazรณn: ubicaciรณn anterior (1)

โ€“ Monitorizaciรณn de ritmo de ECG (ECG de 4 conectores, 3 derivaciones)

โ€“ Pantalla de ECG de 12 derivaciones (utilizando solo LLEAP)

โ€“ Estimulaciรณn

โ€“ Desfibrilaciรณn y cardioversiรณn utilizando desfibriladores reales

Desfibrilaciรณn:

โ€“ La cantidad de descargas requeridas para la conversiรณn automรกtica se fija en cada caso de paciente de la simulaciรณn

Clavijas de conexiรณn para desfibrilaciรณn:

Clavijas de conexiรณn de ECG de 3 derivaciones:

Presiรณn arterial y pulsos:

โ€“ Tensiรณn arterial tomada manualmente mediante la auscultaciรณn de los sonidos de Korotkoff

โ€“ Pulso carotรญdeo bilateral

โ€“ Los pulsos centrales se pueden fijar en normal, dรฉbil o ausente

โ€“ Los pulsos radiales/braquiales se pueden fijar en normal, dรฉbil o ausente

โ€“ Pulsos carotรญdeo, braquial y radial sincronizados con el ECG

โ€“ Fuerza del pulso variable con la tensiรณn arterial

โ€“ La palpaciรณn del pulso se detecta y registra

Caracterรญsticas de RCP

โ€“ De acuerdo con las recomendaciones de 2010

โ€“ Las compresiones generan pulsos palpables, onda de la tensiรณn arterial y artefactos del ECG

โ€“ Profundidad y resistencias realistas de las compresiones

โ€“ Detecciรณn de la profundidad y frecuencia de las compresiones

Caracterรญsticas vasculares

Acceso para tratamiento IV:

El acceso para tratamiento intravenoso es posible en el brazo y la mano derechos. El brazo para tratamiento intravenoso se puede fijar para inserciรณn, infusiรณn y bolo para tratamiento intravenoso en:

โ€“ Las venas perifรฉricas del antebrazo

โ€“ La fosa antecubital y el dorso de la mano

Acceso para tratamiento intraรณseo (IO):

El acceso para una infusiรณn para tratamiento intraรณseo es posible:

โ€“ Tuberosidad tibial (derecha).

โ€“ Malรฉolo medio.

Nota: SimJunior no cuenta con sitios de inyecciรณn intramusculares (IM). No intente realizar inyecciones IM.

Configuraciรณn de sonido para SimJunior SimJunior admite varios sitios para auscultaciรณn y reconocimiento de los sonidos del corazรณn, de los pulmones y de los intestinos. SimJunior tambiรฉn le permite configurar sonidos vocales.

Para obtener mรกs informaciรณn sobre la configuraciรณn de sonidos para SimJunior, consulte las instrucciones de uso de SimPad o los archivos de ayuda de LLEAP.

Page 76: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

74

Software de simulaciรณn

PC del instructor

El PC del instructor utiliza el software LLEAP para manejar las sesiones de simulaciรณn. LLEAP, asรญ como otras aplicaciones รบtiles relacionadas con la simulaciรณn, se encuentra disponible en Laerdal Simulation Home.

Licencia del software El PC del instructor se envรญa desde Laerdal Medical con una licencia activada previamente instalada para LLEAP.

Los cambios o las actualizaciones del hardware del equipo (p. ej., un disco duro o una placa madre nuevos) pueden invalidar la licencia. Pรณngase en contacto con la asistencia local de Laerdal, a fin de obtener ayuda para activar nuevamente la licencia.

Laerdal Simulation HomeLaerdal Simulation Home es una aplicaciรณn desde donde se pueden encontrar e iniciar LLEAP y otros programas de Laerdal relacionados con la simulaciรณn de paciente. Tambiรฉn se pueden abrir desde aquรญ los archivos de ayuda. Laerdal Simulation Home se encuentra en la carpeta de Laerdal Medical en el menรบ de inicio de Windows (Windows 7).

El software utilizado en una sesiรณn de simulaciรณn se puede dividir en las siguientes aplicaciones principales:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server o Session Viewer

Tambiรฉn se utilizan SimDesigner y otras aplicaciones para diseรฑar o preparar una simulaciรณn.

LLEAPLaerdal Learning Application (LLEAP) es la aplicaciรณn del instructor desde donde se ejecuta, se controla y se monitoriza la sesiรณn de simulaciรณn. LLEAP puede funcionar en modo automรกtico o manual. El modo automรกtico se utiliza para escenarios preprogramados mientras que el modo manual ofrece al instructor el control manual completo durante la sesiรณn de simulaciรณn. La ejecuciรณn de simulaciones en modo manual generalmente requiere cierta experiencia mรฉdica para crear simulaciones clรญnicamente sรณlidas.

Voice Conference Application (VCA)El software VCA es necesario para transmitir todos los sonidos vocales utilizados durante la simulaciรณn. Permite al instructor comunicarse mediante el simulador durante la sesiรณn. VCA tambiรฉn se puede utilizar para comunicarse con otros instructores en una red y crear canales independientes por los que solo se puedan comunicar sus miembros.

Patient MonitorLa aplicaciรณn Patient Monitor emula el monitor habitual de un paciente en un hospital. Es la consola del alumno y se puede configurar y controlar tanto por el instructor como por el alumno a travรฉs de los menรบs tรกctiles en pantalla.

Session Viewer y SimView ServerSession Viewer y SimView Server son aplicaciones que registran capturas de pantalla del monitor de paciente y vรญdeo durante la simulaciรณn ademรกs de proporcionar una interfaz para el anรกlisis de la sesiรณn. Una vez que finalice una sesiรณn, los archivos de registro generados en LLEAP se transfieren y fusionan con los archivos de vรญdeo en Session Viewer o SimView Server para la sesiรณn de debriefing.

Session Viewer normalmente se ejecuta localmente en el mismo ordenador que se utiliza para LLEAP, SimView Server se ejecuta en un servidor dedicado de la red local. Durante el primer inicio de LLEAP, se le pedirรก que seleccione un sistema de debriefing disponible en el ordenador o en una red local. Esta opciรณn se puede modificar mรกs adelante.

Otras aplicacionesExisten ademรกs otros programas que se utilizan junto con las sesiones de simulaciรณn, por ejemplo License Manager para gestionar las licencias de los programas y Simulator Firmware & Network Wizard para actualizar el firmware de los simuladores o solucionar los problemas de la red.

SimDesignerSimDesigner es una aplicaciรณn para configurar sus propios escenarios preprogramados. Tambiรฉn se puede utilizar para analizar e imprimir una representaciรณn grรกfica de un escenario.

Se debe instalar SimDesigner para permitir la conversiรณn de los archivos antiguos de aplicaciรณn del instructor a formatos de archivos compatibles con LLEAP.

Archivos de ayuda

Para obtener mรกs informaciรณn sobre el software LLEAP y otras aplicaciones, consulte los archivos de ayuda:

1. Haga clic en <Inicio> <Todos los programas>.

2. Seleccione <Laerdal Simulation Home>.

3. Seleccione <Ayuda>.

Descargas por InternetVisite www.laerdal.com/downloads para descargar el รบltimo manual del usuario y software.

Page 77: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

75

Soft

war

e de

si

mul

aciรณ

n In

trod

ucci

รณn

Con

figur

aciรณ

n de

l sim

ulad

orM

ante

nim

ient

o Pi

ezas

de

repu

esto

y

acce

sori

os

Espe

cific

acio

nes

R

esol

uciรณ

n de

pr

oble

mas

Configuraciรณn del simulador

Cรณmo prepararse para las simulaciones Despuรฉs de que el simulador SimJunior estรฉ preparado y todos los dispositivos interactivos correspondientes (SimPad o PC del instructor y monitor de paciente) estรฉn configurados y listos para su uso, es posible que deban realizarse preparativos finales antes de que SimJunior estรฉ listo para ejecutar simulaciones.

Las preparaciones finales para las simulaciones incluyen las siguientes actividades:

โ€ข Preparaciรณn de la pierna para tratamiento intraรณseo

โ€ข Administraciรณn de fluidos para tratamiento intravenoso

โ€ข Drenaje del exceso de fluidos para tratamiento intravenoso

โ€ข Limpieza del brazo para tratamiento intravenoso

โ€ข Conexiรณn de las placas adaptadoras para desfibrilaciรณn

โ€ข Conexiรณn del manguito del esfigmomanรณmetro

โ€ข Cambiar las pupilas.

โ€ข Conectar un compresor externo.

โ€ข Cambiar la configuraciรณn del compresor interno.

Preparaciรณn de la pierna para tratamiento intraรณseoLa pierna derecha del simulador estรก diseรฑada para practicar las habilidades de infusiรณn para tratamiento intraรณseo. La anatomรญa de la pierna derecha incluye la rodilla, la tibia, tuberosidad tibial y malรฉolo medial. La pierna derecha incluye una cรกnula para tratamiento intravenoso y una bolsa para tratamiento intravenoso para utilizar como depรณsito durante la infusiรณn.

Equipo adicional necesario:

โ€ข Bolsa para tratamiento intravenoso y conjunto de administraciรณn

โ€ข Concentrado de sangre simulada

โ€ข Jeringa de 35 cc y aguja para tratamiento intraรณseo calibre 16

Para llenar la pierna para tratamiento intraรณseo y prepararla para el uso:

1. Levante la pierna en forma vertical.

2. Abra el tapรณn en el talรณn.

3. Con una jeringa, llene el hueso con aproximadamente 240 a 250 ml de sangre simulada.

4. Coloque la cรกnula conectada a una bolsa reservorio para tratamiento intravenoso. (Utilice la pinza para abrir o cerrar la lรญnea segรบn sea necesario, a fin de aliviar la acumulaciรณn de presiรณn).

5. Cierre la cรกnula que se extiende dentro de la bolsa reservorio, a fin de que la sangre simulada permanezca en el hueso para aspiraciรณn.

6. Cuando se llene la bolsa reservorio, pare la infusiรณn y reemplace con una bolsa vacรญa.

Antes de guardar el simulador:

โ€“ Retire la lรญnea para tratamiento intravenoso y el reservorio del pie

โ€“ Permita que drene todo el lรญquido

โ€“ Guarde la pierna sin el tapรณn colocado para permitir que se seque al aire

Nota: No utilice soluciรณn salina. Puede provocar el deterioro de la pierna. Utilice agua destilada o desionizada para evitar la acumulaciรณn de minerales.

Administraciรณn de fluidos para tratamiento intravenoso El brazo derecho para tratamiento intravenoso admite el entrenamiento para la administraciรณn de fรกrmacos para tratamiento intravenoso, inserciรณn para tratamiento intravenoso, infusiรณn y bolo en las venas perifรฉricas del antebrazo, la fosa antecubital y el dorso de la mano.

Utilice una aguja de calibre 20 a 22 para una simulaciรณn de tratamiento intravenoso. A fin de evitar taponar el sistema para tratamiento intravenoso, utilice sรณlo agua destilada o desionizada para simular los fรกrmacos para tratamiento intravenoso.

Page 78: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

76

Configuraciรณn del simulador

Drenaje del exceso de fluidos para tratamiento intravenoso El sistema de fluidos para tratamiento intravenoso es un sistema abierto. Los lรญquidos para tratamiento intravenoso se drenan a medida que se administran.

Antes de cada sesiรณn:

1. Conecte el tubo de desborde para tratamiento intravenoso (en el brazo derecho del simulador) a un recipiente de desborde (como una bolsa para tratamiento intravenoso).

2. Permita que el exceso de fluidos se drene en un recipiente durante la simulaciรณn.

Limpieza del brazo para tratamiento intravenoso Limpie el brazo para tratamiento intravenoso despuรฉs de cada sesiรณn o dรญa de uso purgando el brazo para tratamiento intravenoso con isopropanol al 60% o etanol al 70%.

Instalaciรณn de placas adaptadoras para desfibrilaciรณnEl torso del simulador estรก ajustado con conectores de dos clavijas para los cables del desfibrilador. Antes de intentar la desfibrilaciรณn, deberรก desatornillar y retirar las clavijas de conexiรณn del desfibrilador.

Con el simulador, se incluyen dos placas adaptadoras para desfibrilaciรณn. Las placas adaptadoras para el desfibrilador se deben ajustar en su lugar antes de utilizar un desfibrilador real con palas de desfibrilaciรณn.

Durante la desfibrilaciรณn Se puede utilizar un desfibrilador convencional (no incluido) en el SimJunior. Durante la desfibrilaciรณn real, el desfibrilador y el simulador pueden presentar un riesgo de descarga. Se deben tomar todas las precauciones de seguridad estรกndar al utilizar el desfibrilador en el simulador.

Advertencias:

โ€“ La desfibrilaciรณn se debe llevar a cabo en los conectores del desfibrilador รบnicamente.

โ€“ No desfibrile el simulador sin la piel del torso colocada.

Conexiรณn del manguito del esfigmomanรณmetro

El simulador se entrega con un manguito de esfigmomanรณmetro personalizado. Conecte el tubo al conector de PA blanco en la parte trasera del Link Box antes del uso.

Nota: El altavoz de la presiรณn arterial del simulador se encuentra en la fosa antecubital izquierda, que aparece a continuaciรณn seรฑalada con un cรญrculo. Los pulsos radial y braquial se encuentran en las รกreas rectangulares.

Calibraciรณn del manguito para medir la presiรณn arterial en LLEAP

1. Seleccione <Herramientas> en el menรบ

2. Seleccione <Configuraciรณn del simulador> en el menรบ Herramientas.

3. Seleccione <Calibrar presiรณn arterial> en el submenรบ.

4. Siga las instrucciones del asistente en pantalla para realizar la calibraciรณn

Calibraciรณn del manguito para medir la presiรณn arterial en SimPad

1. Seleccione <Calibraciรณn> en el menรบ.

2. Seleccione <Calibrar la PA> en el menรบ desplegable.

3. Siga las instrucciones del asistente en pantalla para realizar la calibraciรณn.

Precauciรณn: El simulador no debe estar en contacto con superficies ni objetos conductores de electricidad durante la desfibrilaciรณn.

Page 79: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

77

Soft

war

e de

si

mul

aciรณ

n C

onfig

urac

iรณn

del s

imul

ador

In

trod

ucci

รณn

Man

teni

mie

nto

Piez

as d

e re

pues

to

y ac

ceso

rios

Es

peci

ficac

ione

s

Res

oluc

iรณn

de

prob

lem

as

Configuraciรณn del simulador

Cambiar las pupilas

SimJunior se entrega con pupilas normales instaladas en los ojos. SimJunior incluye un kit separado que contiene pupilas plรกsticas insertables (en punto o dilatadas).

Para cambiar las pupilas:

1. Con cuidado, abra completamente los pรกrpados; tenga cuidado de no rasgar la piel de la cara del simulador.

2. Utilizando la ventosa de succiรณn proporcionada en el kit o con el borde de su uรฑa, retire con cuidado la pupila del ojo.

3. Reemplace la pupila por la deseada, utilizando la ventosa de succiรณn o presionando con suavidad en el lugar.

Uso de un compresor externo El compresor externo se conecta al tubo transparente que se encuentra en el grupo de cables que sale del lado derecho del simulador. Cuando utilice un compresor externo, puede apagar el compresor interno mediante SimPad o LLEAP.

Para obtener mรกs informaciรณn sobre los compresores externos y los paneles reguladores compatibles con SimJunior, comunรญquese con su representante local de Laerdal.

Apagado o encendido del compresor interno en SimPad

1. Inicie <Modo manual>, seleccione un tema e inicie la sesiรณn.

2. Seleccione <Varios> en el menรบ interior.

3. Seleccione <Compresor> en el submenรบ.

4. Realice los cambios deseados en el cuadro de diรกlogo y haga clic en OK.

Apagado o encendido del compresor interno en LLEAP

1. Seleccione <Herramientas> en el menรบ.

2. Seleccione <Configuraciรณn del simulador> en el menรบ Herramientas.

3. Seleccione <Compresor interno> en el submenรบ.

4. Realice los cambios deseados en el cuadro de diรกlogo y haga clic en OK.

Page 80: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

78

Nota: Para obtener informaciรณn sobre piezas de repuesto, consulte la secciรณn: Piezas de repuesto y accesorios.

Antes del almacenamiento o el envรญo

โ€“ Purgue el brazo para tratamiento intravenoso con alcohol isopropรญlico al 60% o etanol al 70%. Abra la vรกlvula de drenaje en la parte inferior del pie derecho del simulador.

Mantenimiento

Mantenimiento despuรฉs de cada sesiรณn de simulaciรณnSe requieren las siguientes medidas preventivas para asegurar la longevidad del simulador SimJunior.

โ€“ Apague el SimPad, Link Box y PC

โ€“ De ser necesario, cargue las baterรญas

โ€“ Purgue el sistema del brazo para tratamiento intravenoso y drene la pierna para tratamiento intraรณseo (deje abierto el tapรณn en la parte inferior de la pierna para tratamiento intraรณseo)

โ€“ Despuรฉs de cada sesiรณn en la que se utilice el brazo para tratamiento intravenoso, purgue el brazo para tratamiento intravenoso con alcohol isopropรญlico al 60% o etanol al 70%.

โ€“ Limpie la piel con un trapo hรบmedo

โ€“ Retire la ropa mojada

โ€“ Retire los residuos de cinta adhesiva con un trapo hรบmedo o alcohol para frotar.

โ€“ En funciรณn del uso del simulador, reemplace los mรณdulos que se hayan consumido o daรฑado

โ€“ Reemplace los cables o los conectores que muestren daรฑos visibles

โ€“ Personal cualificado debe llevar a cabo un mantenimiento a intervalos periรณdicos

Siempre lleve a cabo un mantenimiento:

โ€“ Si se han derramado lรญquidos en el simulador o sobre este

โ€“ Despuรฉs del uso en ambientes con polvo

Page 81: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

79

Con

figur

aciรณ

n de

l sim

ulad

orM

ante

nim

ient

o So

ftw

are

de

sim

ulac

iรณn

Intr

oduc

ciรณn

Pi

ezas

de

repu

esto

y

acce

sori

os

Espe

cific

acio

nes

R

esol

uciรณ

n de

pr

oble

mas

Mantenimiento

Cรณmo abrir el torso

Abra el torso del simulador para realizar procedimientos, tales como:

โ€“ Colocar o reemplazar extremidades.

โ€“ Cambiar la baterรญa del simulador

โ€“ Reemplazar la almohadilla de elevaciรณn del tรณrax y la almohadilla del pulmรณn

โ€“ Volver a colocar la piel del torso

โ€“ Para inspecciรณn general.

Advertencia: Abra el torso de izquierda a derecha; desenganche la piel con suavidad. No tire con fuerza para levantar la piel del torso; esto podrรญa daรฑar los cables del tรณrax.

1. Desenganche las sujeciones de piel del torso en el lado izquierdo del torso y de cada hombro.

Cรณmo reemplazar la baterรญa del simulador

1. Abra el torso del simulador.

2. Pliegue la piel del torso hacia el lado derecho.

3. Desconecte el cable de conexiรณn de desfibrilaciรณn.

4. El cable de conexiรณn de desfibrilaciรณn debe desconectarse en el lado derecho del simulador, debajo de la forma del tรณrax.

Nota: NO desconecte los tubos y los cables que conectan la espuma del estรณmago con el simulador.

5. Vuelva a colocar la piel del torso realizando los pasos 1 a 4 en orden inverso.

2. Deslice la baterรญa fuera de la brida de sujeciรณn de la baterรญa.

3. Tire de la conexiรณn de alimentaciรณn de la baterรญa del interior del simulador. Desenganche la conexiรณn de alimentaciรณn de la baterรญa.

4. Levante la baterรญa fuera del simulador.

5. Vuelva a colocar la baterรญa cargada o instale una nueva baterรญa de SimJunior aprobada por Laerdal.

6. Conecte la baterรญa al simulador.

7. Vuelva a colocar la piel del torso.

Page 82: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

80

Mantenimiento

Carga de la baterรญa del simulador

La baterรญa del simulador se carga a sรญ misma a medida que se opera. De ser necesario, la baterรญa del simulador se puede cargar utilizando un adaptador de alimentaciรณn externa opcional.

1. Desconecte el simulador de la alimentaciรณn mediante el Link Box.

2. Saque la baterรญa del simulador.

3. Conecte un cargador de baterรญas externo aprobado (con un cable de alimentaciรณn que cumpla las especificaciones locales) a la parte inferior de la baterรญa del simulador. Conecte el cable de alimentaciรณn del cargador de la baterรญa en una toma de corriente de pared.

4. Cuando la baterรญa haya terminado de cargarse, vuelva a colocar la baterรญa en el simulador.

Cรณmo reemplazar la almohadilla de elevaciรณn del tรณrax La almohadilla de elevaciรณn del tรณrax estรก ubicada en el extremo inferior de la placa del tรณrax, centrada debajo de los pulmones.

1. Abra la piel del torso para exponer la placa del tรณrax. Consulte Cรณmo abrir el torso.

2. Desconecte la cรกnula transparente de la almohadilla del pulmรณn y retire la almohadilla. Para obtener mรกs informaciรณn, consulte Cรณmo reemplazar la almohadilla del pulmรณn.

3. Desconecte la cรกnula transparente de la almohadilla de elevaciรณn del tรณrax.

4. Deseche la almohadilla usada.

5. Inserte una almohadilla nueva.

6. Vuelva a conectar la cรกnula a la almohadilla nueva.

7. Cierre el torso y vuelva a colocar la piel del torso.

Cรณmo reemplazarla almohadilla del pulmรณn Si se producen pรฉrdidas, se debe reemplazar la almohadilla del pulmรณn (en la cavidad torรกcica).

1. Abra la piel del torso.

2. Desconecte la cรกnula transparente debajo de cada lado de la almohadilla del pulmรณn. Consulte la ilustraciรณn del paso 2 en Cรณmo reemplazar la almohadilla de elevaciรณn del tรณrax.

3. Desconecte el gancho de la almohadilla del pulmรณn del centro superior.

4. Con suavidad, retire la porciรณn de la parte central superior de la almohadilla del pulmรณn de su orificio.

5. Revierta el proceso para instalar la nueva almohadilla del pulmรณn.

Page 83: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

81

Con

figur

aciรณ

n de

l sim

ulad

orM

ante

nim

ient

o So

ftw

are

de

sim

ulac

iรณn

Intr

oduc

ciรณn

Pi

ezas

de

repu

esto

y

acce

sori

os

Espe

cific

acio

nes

R

esol

uciรณ

n de

pr

oble

mas

Cรณmo reemplazar las pieles del simulador Es posible que se necesite reemplazar la piel del simulador si estรก desgarrada, perforada o manchada.

Piel del torso:

Para reemplazar la piel del torso del simulador, consulte Cรณmo abrir el torso.

Piel del brazo:

Para reemplazar la piel del brazo del simulador:

1. Retire la piel usada del brazo del simulador desplazรกndola hacia abajo por el brazo y la mano o *corte la piel.

Para unir el brazo nuevo:

Mantenimiento

Cรณmo reemplazar el brazo derecho para tratamiento intravenoso derecho

1. Abra el torso; consulte la secciรณn Cรณmo abrir el torso.

2. Retire el brazo anterior desatornillando el perno que sujeta el brazo al hombro del simulador.

3. Asegรบrese de que el tornillo del hombro estรฉ lo suficientemente suelto como para permitir que el eje del brazo se deslice hacia afuera fรกcilmente.

4. Deseche el brazo anterior de acuerdo con las pautas especificadas.

1. Asegรบrese de que el tornillo del hombro estรฉ lo suficientemente suelto como para permitir que el eje del brazo se deslice fรกcilmente hasta quedar en su lugar.

2. Conecte los del brazo a los puntos de conexiรณn correspondientes en el torso.

3. Con cuidado, empuje el eje del brazo en la escuadra del hombro, de modo que el eje estรฉ alineado con el interior de la escuadra.

4. Ajuste el tornillo del hombro con una llave Allen.

Cรณmo reemplazar la pierna derecha para tratamiento intraรณseo Para retirar la pierna inferior derecha:

1. Asegรบrese de que cualquier lรญquido en la pierna se haya drenado.

2. Retire la pierna para tratamiento intraรณseo desatornillando el perno que la sujeta al muslo.

3. Deslice la parte inferior de la pierna para tratamiento intraรณseo fuera del muslo.

4. Deseche la pierna para tratamiento intraรณseo usada de acuerdo con las pautas especificadas.

Revierta el proceso anterior para unir la pierna para tratamiento intraรณseo nueva.

Advertencia: *No pinche ni corte el molde del brazo.

2. Deseche la piel usada.

3. Lubrique dentro de la piel nueva del brazo con detergente lรญquido suave mezclado con agua.

4. Lubrique (o enjabone) el molde con una mezcla de agua y jabรณn lรญquido suave.

5. Deslice la mano del simulador dentro de la piel.

6. Coloque la piel sobre los dedos hasta que encaje (como con un guante).

7. Deslice la piel hacia arriba, sobre el molde del brazo.

Page 84: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

82

Resoluciรณn de problemas

Configuraciรณn del sistema

Problema

โ€ข Pรฉrdida de datos o fallo total del sistema (fallo general del sistema).

Soluciรณn posible

โ€ข En caso de que se apague el sistema o todos los datos se pierdan o corrompan, comunรญquese con su centro de servicio local de Laerdal.

LLEAPโ€ข Consulte Archivos de ayuda del software > LLEAP > Guรญa de

soluciรณn de problemas (a la ayuda se puede acceder desde Laerdal Simulation Home)

Laerdal Patient Monitorโ€ข Consulte Archivos de ayuda del software > Laerdal Patient

Monitor > Guรญa de soluciรณn de problemas. (A la ayuda se puede acceder desde Laerdal Simulation Home)

Sesiรณn de debriefing y grabaciรณn de vรญdeoโ€ข Consulte la secciรณn de soluciรณn de problemas en la Ayuda de

SimView (accesible mediante un enlace en la parte inferior de la pantalla de SimView) o la Guรญa de soluciรณn de problemas desde la Ayuda de SessionViewer (accesible desde Laerdal Simulation Home)

Simulador

Problema

โ€ข Comportamiento impredecible.

Soluciones posibles

โ€ข Los fallos de funcionamiento del simulador pueden ser provocados por cables, tubos o conectores sueltos. Abra el torso y verifique si algรบn elemento parece haber sido desconectado o tiene pรฉrdidas. Consulte la secciรณn: Configuraciรณn del simulador - Cรณmo abrir el torso.

โ€ข En caso de pรฉrdida de lรญquidos, apague el simulador y pรณngase en contacto con el servicio tรฉcnico de Laerdal.

Contaminaciรณn de las vรญas aรฉreas

Problema

โ€ข Las vรญas aรฉreas del simulador se han contaminado por las ventilaciones boca a boca.

Soluciรณn posible

โ€ข Limpie la parte externa del simulador con toallitas para simulador. Limpie el interior de la cavidad oral con toallitas para simulador. Cambie la almohadilla del pulmรณn; consulte la secciรณn: Mantenimiento: Cรณmo reemplazar la almohadilla del pulmรณn.

Movimiento del tรณrax

Problema

โ€ข Ausencia de elevaciรณn del tรณrax en el simulador.

Soluciones posibles

โ€ข Verifique que la alimentaciรณn del simulador estรฉ encendida.

โ€ข En SimPad o LLEAP, compruebe que โ€“ la frecuencia respiratoria de la vรญa aรฉrea no estรฉ fijada en cero

โ€“ la elevaciรณn del tรณrax no estรฉ desactivada

โ€“ el ECG estรฉ definido en un ritmo de perfusiรณn.

โ€“ no estรฉn fijadas complicaciones en la vรญa aรฉrea como mรกxima resistencia al aire o laringoespasmo.

โ€“ Verifique que el compresor integrado estรฉ habilitado en LLEAP. Consulte la secciรณn: Cรณmo apagar el compresor interno.

โ€ข Verifique que cualquier fuente externa de aire comprimido estรฉ apagada y que el tubo de aire estรฉ desconectado del simulador.

โ€ข Es posible que el compresor interno se haya sobrecalentado. Espere aproximadamente 20 minutos para que se enfrรญe.

โ€ข La elevaciรณn del tรณrax estรก fijada en bilateral (por ejemplo, si el tubo ET se inserta demasiado en los bronquios).

โ€ข La almohadilla de elevaciรณn del tรณrax tiene pรฉrdidas o la cรกnula que se conecta a la almohadilla de elevaciรณn del tรณrax estรก torcida, enroscada o desconectada. Reemplace la almohadilla de elevaciรณn del tรณrax si tiene pรฉrdidas; consulte Mantenimiento: Cรณmo reemplazar la almohadilla de elevaciรณn del tรณrax.

โ€ข Compruebe que no haya fugas en el tubo de aire y verifique que todas las conexiones estรฉn intactas. Reemplace la secciรณn de la cรกnula si tiene pรฉrdidas.

โ€ข Movimientos superficiales del tรณrax y el compresor interno funciona en forma continua. Es posible que el compresor interno estรฉ desgastado. Pรณngase en contacto con el servicio tรฉcnico de Laerdal.

Pulmones

Problema

โ€ข Los pulmones no funcionan adecuadamente

Soluciones posibles

โ€ข Abra el torso y la placa del tรณrax. Verifique que los pulmones tengan libertad para expandirse y que no estรฉn restringidos por ningรบn cable.

Page 85: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

83

Man

teni

mie

nto

Res

oluc

iรณn

de

prob

lem

as

Con

figur

aciรณ

n de

l sim

ulad

orSo

ftw

are

de

sim

ulac

iรณn

Intr

oduc

ciรณn

Pi

ezas

de

repu

esto

y

acce

sori

os

Espe

cific

acio

nes

Resoluciรณn de problemas

โ€ข Verifique que la almohadilla del pulmรณn estรฉ conectada de forma adecuada y que los tubos no estรฉn torcidos.

โ€ข Verifique que la almohadilla del pulmรณn estรฉ en una posiciรณn horizontal e insertada correctamente.

โ€ข Verifique que no haya defectos ni desgarros en la almohadilla del pulmรณn.

โ€ข Verifique que no haya obstrucciones dentro de la vรญa aรฉrea del simulador que puedan bloquear el flujo de aire.

โ€ข Si no se producen cambios al ajustar la distensibilidad pulmonar, pรณngase en contacto con el servicio tรฉcnico de Laerdal.

โ€ข Si no se producen cambios en la resistencia pulmonar, pรณngase en contacto con el servicio tรฉcnico de Laerdal.

Ruido mecรกnico durante la auscultaciรณnEn LLEAP, haga clic en <Foco de auscultaciรณn>.

Pulsos (radial y braquial)

Problema

โ€ข No se sienten los pulsos.

Soluciones posibles

โ€ข Es posible que la piel estรฉ muy apretada sobre las unidades del pulso; vuelva a ajustar la piel y reinicie.

โ€ข Asegรบrese de que la presiรณn arterial sistรณlica estรฉ fijada en, al menos, 60.

โ€ข Asegรบrese de que el compresor estรฉ ENCENDIDO.

Nota: Si el pulso radial estรก fijado por debajo de 60, es posible que los pulsos perifรฉricos desaparezcan.

Apagado del simulador

Problema

โ€ข El simulador no responde.

Soluciรณn

1. Apague el Link Box.

2. Apague el SimPad o, si utiliza LLEAP, apague el PC del instructor.

3. Reinรญcielo todo.

Si el simulador sigue sin responder, comunรญquese con su representante de Laerdal.

Page 86: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

84

Notas

Page 87: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

85

Espe

cific

acio

nes

R

esol

uciรณ

n de

pr

oble

mas

M

ante

nim

ient

o C

onfig

urac

iรณn

del s

imul

ador

Soft

war

e de

si

mul

aciรณ

n In

trod

ucci

รณn

Piez

as d

e re

pues

to

y ac

ceso

rios

Especificaciones

Dimensiones generales Longitud/anchura (solo simulador): 120 cm x 42,5 cm Peso (solo simulador): 11,36 kg

Alimentaciรณn del simulador Alimentaciรณn externa: Voltaje de entrada 9 VCC, 1,5 A Baterรญa interna: 7,4 V, 4,4 Ah, iones de litio

รšnicamente utilice las baterรญas y la fuente de alimentaciรณn externa de SimJunior aprobadas.

Presiรณn de aire Tanque de aire interno: Mรกx. 6 psi Conexiรณn de aire externa: Mรกx. 16 psi

Lรญmites de temperatura Temperaturas de funcionamiento: +4 ยฐC a 40 ยฐC Temperaturas de almacenamiento: -15 ยฐC a 50 ยฐC

Entorno: solo simulador Humedad relativa: 20% a 90% (sin condensaciรณn) NO lo utilice al aire libre en condiciones hรบmedas. No se ha testado con spray salino.

Comunicaciรณn por RF Rango de funcionamiento: 10 m mรกx.

Cuadro de materiales del simulador Ropas: Algodรณn, nailon Piel y vรญa aรฉrea: PVC Plรกstico duro externo: PVC, ABS Plรกsticos internos: Silicona, TPU, PVC, nitrilo ABS, POM, Nylon + GF Epoxi-poliuretano Componentes metรกlicos: Aluminio, latรณn, acero

Requisitos mรญnimos del ordenador

โ€ข Intel i-core 3ยช generaciรณn o posterior

โ€ข Puntuaciรณn sobre 3000 PassMark - Procesador CPU

โ€ข 4 GB RAM

โ€ข 120 GB de espacio en el disco duro

โ€ข 1.366 x 768 o superior

โ€ข Auriculares con micrรณfono

โ€ข Puertos USB - 2

Requisitos mรญnimos del software

โ€ข Windows 7 o Windows 8

โ€ข 100% de puntos por pulgada

Lรญquidos para limpiar Para limpiar el simulador, utilice uno de los siguientes:

โ€“ Alcohol isopropรญlico al 60%.

โ€“ Etanol al 70%.

โ€“ Soluciรณn suave de agua y jabรณn lรญquido.

Lรญquidos para tratamiento intravenoso Solo utilice agua destilada o desionizada para simular lรญquidos para tratamiento intravenoso e intraรณseo.

Page 88: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

86

Notas

Page 89: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

87 Piez

as d

e re

pues

to

y ac

ceso

rios

Espe

cific

acio

nes

Res

oluc

iรณn

de

prob

lem

as

Man

teni

mie

nto

Con

figur

aciรณ

n de

l sim

ulad

orSo

ftw

are

de

sim

ulac

iรณn

Intr

oduc

ciรณn

Piezas de repuesto y accesorios

Piezas de repuesto y accesorios Para obtener la รบltima versiรณn de las piezas de repuesto y accesorios, visite www.laerdal.com

Page 90: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

88

Notas

Page 91: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

89

Manutenzione 100

โ€“ Manutenzione dopo ogni sessione di simulazione 100 โ€“ Apertura del tronco 101 โ€“ Sostituzione della batteria del simulatore 101 โ€“ Ricarica della batteria del simulatore 102 โ€“ Sostituzione della camera d'aria per il

sollevamento del torace 102 โ€“ Sostituzione della camera d'aria dei polmoni 102 โ€“ Sostituzione delle pelli del simulatore 103 โ€“ Sostituzione del braccio destro per EV 103 โ€“ Sostituzione della gamba destra per infusione intraossea 103

Risoluzione dei problemi 104

Introduzione 90

โ€“ Informazioni normative 90 โ€“ Cura generale del simulatore 91โ€“ Panoramica di SimJunior 93 โ€“ Caratteristiche di SimJunior 94

Preparazione del simulatore 97

โ€“ Preparazione alle simulazioni 97 โ€“ Preparazione della gamba per infusione intraossea 97 โ€“ Somministrazione di fluidi via EV 97 โ€“ Drenaggio dei fluidi per EV in eccesso 98 โ€“ Pulizia del braccio per EV 98 โ€“ Installazione delle piastre adattatore per defibrillazione 98 โ€“ Collegamento del bracciale per la misurazione

della pressione sanguigna 98 โ€“ Calibratura del bracciale per la misurazione della

pressione sanguigna in LLEAP 98 โ€“ Calibratura del bracciale per la misurazione della

pressione sanguigna in SimPad 98 โ€“ Sostituzione delle pupille 99 โ€“ Uso di un compressore esterno 99

Specifiche 107

Software di simulazione 96

โ€“ PC dell'istruttore 96 โ€“ Licenza del software 96 โ€“ Laerdal Simulation Home 96โ€“ LLEAP 96โ€“ Voice Conference Application 96โ€“ Patient Monitor 96โ€“ Session Viewer e SimView Server 96โ€“ Altre applicazioni 96โ€“ SimDesigner 96โ€“ File della guida 96โ€“ Download dal Web 96

Parti di ricambio e accessori 109

Sommario IT

Page 92: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

90

Ioni di litio

Introduzione

Introduzione al simulatore SimJuniorโ„ข SimJunior รจ un simulatore realistico di un paziente pediatrico con dimensioni naturali, nato da una collaborazione di Laerdal con l'American Academy of Pediatrics. Puรฒ essere utilizzato per la formazione di professionisti sanitari, singoli e in team, in svariati settori medici.

Il simulatore SimJunior viene fornito completamente assemblato. Non รจ necessario assemblare altre parti del simulatore.

Per informazioni dettagliate su come preparare SimJunior per una simulazione, consultare la sezione "Preparazione del simulatore".

Guida per SimJunior Istruzioni per l'uso

Istruzioni dettagliate e illustrazioni per l'uso del simulatore SimJunior.

Manuali per l'uso del produttore originale

Attenersi a tutti i manuali per l'uso e alle etichette dei produttori originali. Le istruzioni per l'uso di SimJunior non sostituiscono in alcun modo quelle del produttore originale.

Guida di configurazione rapida di SimJunior

Guida dettagliata per l'impostazione del sistema di simulazione SimJunior.

Istruzioni per l'uso di SimPad

Il manuale Istruzioni per l'uso di SimPad fornisce istruzioni per usare la Link Box e SimPad con SimJunior.

File della guida di LLEAP (Laerdal Learning Application)

รˆ possibile accedere ai file della guida di LLEAP da Laerdal Simulation Home, vedere Laerdal Simulation Home

Gli argomenti della guida includono:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

Supporto tecnico

Per ricevere supporto tecnico, rivolgersi al centro di assistenza Laerdal locale.

Download dal Web

Per scaricare le Istruzioni per l'uso e le piรน recenti versioni del software di simulazione, visitare il sito Web www.laerdal.com/downloads.

Contenuto di SimCenter SimCenter offre facile accesso a contenuti verificati, sviluppati da esperti di simulazione di tutto il mondo, che consentono di trarre vantaggio dalla loro esperienza e ottenere il massimo da ogni opportunitร  di apprendimento. รˆ disponibile un'ampia gamma di scenari sviluppati appositamente per SimJunior. Visitare il sito www.mysimcenter.com per scoprire come ottimizzare l'esperienza di apprendimento.

Informazioni normative

Federal Communications Commission StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Attenzione Alterazioni o modifiche non espressamente approvati dall'ente responsabile per la conformitร  potrebbero annullare l'autorizzazione per l'uso dell'apparecchiatura.

Le batterie agli ioni di litio devono essere riciclate.

Laerdal Medical AS dichiara che la presenza del marchio CE sul prodotto ne attesta la conformitร  con i requisiti essenziali e altre disposizioni pertinenti della direttiva 1999/5/CE.

Eliminare in conformitร  con i requisiti e le normative locali.

Page 93: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e di

si

mul

azio

ne

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e In

trod

uzio

ne

Ris

oluz

ione

dei

pr

oble

mi

91

Introduzione

Cura generale del simulatore Attenersi alle istruzioni seguenti per garantire prestazioni ottimali e la massima durata del simulatore e dei suoi componenti.

Cura generale

Per preservare la pelle del simulatore, lavarsi le mani prima dell'uso e collocare il simulatore su una superficie pulita. Laerdal raccomanda di

โ€“ Indossare guanti durante le simulazioni. Evitare l'uso di guanti di plastica colorati perchรฉ potrebbero macchiare la pelle del simulatore.

โ€“ Non usare vicino al simulatore pennarelli, penne stilografiche, acetone, iodio o altri farmaci che macchiano. Accertarsi di non collocare il simulatore su fogli di giornale o su carta colorata. Eventuali macchie potrebbero risultare permanenti.

โ€“ Lavare la pelle del simulatore con sapone delicato e acqua.

Non applicare le seguenti tecniche sul simulatore perchรฉ impediscono la corretta sterilizzazione:

โ€“ Ventilazione bocca a bocca o con protezione facciale

โ€“ Inserimento di vomito finto o liquidi per l'aspirazione

โ€“ Se una sessione di training prevede l'uso di fluidi nel braccio per EV, svuotare il braccio immediatamente al termine della sessione.

โ€“ Usare solo il lubrificante per vie aeree Laerdal e applicarlo in modica quantitร .

โ€“ Sciacquare, ripulire e asciugare i componenti modulari del simulatore.

โ€“ Ripiegare la pelle del tronco e cospargerne l'interno di borotalco per ridurre l'attrito. Non far cadere la polvere di borotalco nella cavitร  toracica del simulatore.

Condizioni ambientali Se fa freddo, attendere che il simulatore abbia raggiunto la temperatura ambiente prima di accenderlo.

Per evitare il surriscaldamento e ridurre l'usura

โ€“ Se si usa il simulatore a temperature superiori ai 40 ยฐC, lasciarlo raffreddare tra una sessione di training e la seguente.

โ€“ Se si usa su un lettino, non coprire il simulatore con coperte pesanti che impediscono l'uscita del calore dal simulatore.

Uso generale del simulatore Per evitare infortuni alle persone o danni al prodotto, adottare le precauzioni indicate di seguito.

โ€“ Immettere fluidi nel simulatore solo nel modo indicato in questo documento

โ€“ Prima di inserire qualsiasi strumento, tubo o dispositivo per le vie aeree, lubrificare le vie aeree orali e nasali con il prodotto fornito. Prima dell'uso lubrificare anche gli strumenti e i tubi.

โ€“ Non introdurre aria umidificata nel sistema durante la ventilazione

โ€“ Non usare il simulatore se i tubi e i cavi interni non sono collegati.

โ€“ Non usare mai il simulatore SimJunior all'esterno in condizioni di elevata umiditร , poichรฉ rappresenta un rischio di scosse elettriche e si potrebbe danneggiare il simulatore.

โ€“ L'uso di un defibrillatore a temperature superiori a 35 ยฐC potrebbe portare a surriscaldamento.

Avvertenza: non usare attrezzature per l'applicazione automatica di compressioni toraciche sul simulatore.

Avviso relativo al lattice: questo prodotto contiene lattice di gomma naturale che puรฒ provocare reazioni allergiche a contatto con soggetti sensibili.

Rischi della defibrillazione SimJunior supporta la defibrillazione.

Su SimJunior รจ possibile usare un normale defibrillatore. Durante la defibrillazione, il defibrillatore e il simulatore possono presentare il pericolo di scosse elettriche. Quando si usa un defibrillatore sul simulatore, occorre adottare tutte le precauzioni di sicurezza standard.

โ€ข Leggere e seguire tutte le istruzioni operative e di sicurezza fornite con il defibrillatore e le attrezzature associate.

โ€ข Attenersi al protocollo di defibrillazione, evitando di toccare gli elettrodi esterni e le relative sedi durante la defibrillazione. Possono essere rilasciate scariche fino a 300 joule.

โ€ข Il mancato rispetto delle misure di sicurezza potrebbe causare lesioni o la morte.

Per ulteriori informazioni, consultare il manuale per l'uso del defibrillatore.

Avvertenze

โ€“ Eseguire la defibrillazione usando i connettori o le piastre per il defibrillatore situate sul torace del simulatore. Non usare i connettori ECG, che sono esclusivamente progettati per il monitoraggio ECG. La defibrillazione sui connettori ECG causa danni all'impianto elettronico interno del simulatore e potrebbe provocare lesioni alle persone.

โ€“ Non applicare la defibrillazione al simulatore se รจ spento o non funziona regolarmente.

Dichiarazione di non responsabilitร  L'uso del sistema di simulazione del paziente SimJunior per il training del personale deve essere supervisionato da personale tecnico o medico, con formazione adeguata sui principi didattici e sui protocolli medici riconosciuti. Come avviene per tutti i simulatori e simili dispositivi di formazione, le caratteristiche anatomiche e il modello fisiologico potrebbero presentare approssimazioni, variazioni e inesattezze. Pertanto, Laerdal non garantisce la totale accuratezza di tutte le caratteristiche.

Garanzia internazionale Consultare il libretto di garanzia internazionale Laerdal o visitare il sito www.laerdal.com.

Paese di origine - SimJunior รจ fabbricato negli Stati Uniti.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 94: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

92

Introduzione

Non somministrare piรน di 3 scariche in 45 secondi, seguite da 1 minuto di RCP, per evitare il surriscaldamento durante la defibrillazione. Dopo 30 minuti, interrompere la somministrazione di scariche elettriche per almeno 15 minuti prima di riprendere una nuova sequenza. Non ripetere questa sequenza per un periodo superiore a 4 ore. Inoltre, non somministrare piรน di 2 scariche da 300 J al minuto.

Avvertenze

โ€“ Durante la defibrillazione il simulatore non deve entrare in contatto con oggetti o superfici conduttive.

โ€“ Evitare l'uso in ambienti altamente infiammabili. Ad esempio, durante la defibrillazione dovrebbero essere evitate alte concentrazioni di ossigeno puro. Se viene utilizzato ossigeno concentrato vicino al simulatore, verificare che l'ambiente sia ben ventilato.

โ€“ Il tronco del simulatore deve essere mantenuto sempre asciutto.

โ€“ Prima di procedere alla defibrillazione, lasciar adattare il simulatore alle condizioni ambientali. Bruschi sbalzi di temperatura potrebbero portare alla formazione di condensa sui componenti elettronici, con conseguente pericolo di scosse elettriche.

โ€“ Per evitare la formazione di depressioni puntiformi sulla pelle del tronco in prossimitร  degli elettrodi, non applicare gel conduttivo o elettrodi di defibrillazione conduttivi destinati all'uso su pazienti.

โ€“ Una pressione eccessiva sui connettori di defibrillazione durante la defibrillazione potrebbe causare archi elettrici e depressioni.

โ€“ Non defibrillare il simulatore se la pelle del tronco non รจ presente.

Rischi meccanici o elettrici Non usare il simulatore SimJunior se:

โ€“ gli arti non sono attaccati al tronco

โ€“ le porzioni di pelle sono lacerate o non sono fissate correttamente

โ€“ i cavi interni o esterni, i tubi o i connettori sono danneggiati

โ€“ si nota una perdita di liquido all'interno o sul simulatore

โ€“ si sentono rumori insoliti che indicano una perdita d'aria o un danno meccanico

โ€“ sono presenti segni di guasto elettrico, come, ad esempio, la mancata reazione da parte del simulatore o la presenza di un odore insolito o di fumo

Avvertenza

โ€“ Per evitare rischi di pizzicamento, non usare il simulatore senza le pelli esterne.

Uso e manutenzione delle batterie

โ€“ Usare sempre batterie approvate per alimentare SimJunior, Link Box e SimPad.

โ€“ Verificare che le batterie siano installate correttamente. L'inserimento o il collegamento errato delle batterie potrebbe causare un cortocircuito.

Avvertenze

โ€“ Eliminare le batterie nel rispetto delle normative locali.

โ€“ Il caricabatterie esterno deve essere utilizzato solo in ambienti chiusi.

โ€“ Caricare la batteria del simulatore solo con una temperatura compresa tra 0 e 40 ยฐC.

โ€“ Non trattare in modo improprio, smontare e tentare di riparare la batteria. Non usare batterie che appaiano visibilmente danneggiate, guaste o che sembrano presentare una perdita.

โ€“ Prestare molta attenzione ad evitare il contatto diretto con parti elettriche, molto calde o che emettono fumo. In presenza di perdite, scollegare e rimuovere la batteria quando si ritiene che le condizioni siano sicure per farlo.

โ€“ L'esposizione a liquidi rappresenta un pericolo di esplosione.

โ€“ Ogni 30 cicli di ricarica, scaricare completamente la batteria prima di ricaricarla, lasciando il simulatore alimentato a batteria in funzione fino allo spegnimento automatico.

โ€“ Sostituire solo con batterie per SimJunior di Laerdal.

Conservazione e trasporto

โ€“ Non conservare mai batterie completamente cariche per oltre un mese.

โ€“ Per i trasporti aerei, la batteria del simulatore puรฒ essere lasciata all'interno del simulatore.

โ€“ Per il trasporto di batterie aggiuntive, contattare la compagnia aerea o di trasporto per informazioni sui regolamenti in vigore.

Avvertenza

โ€“ Il simulatore SimJunior risulta pesante quando inserito insieme agli accessori nella valigetta da trasporto. Verificare sempre che SimJunior sia saldamente fissato durante il trasporto e quando viene riposto per evitare lesioni a persone o danni al prodotto.

Page 95: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e di

si

mul

azio

ne

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e In

trod

uzio

ne

Ris

oluz

ione

dei

pr

oble

mi

93

Gamba per IO

Porta di riempimento gamba per IO

Simulatore SimJunior

Connettore ECG del braccio destro

Piastra per defibrillazione sternale

Braccio per EV

Connettore ECG della gamba destra

Cavo di alimentazione

Aria esterna connessa

Cavo del simulatore (60 pin)

Introduzione

Connettore ECG del braccio sinistro

Braccio per la misurazione della pressione sanguigna

Piastra per defibrillazione apicale

Connettore ECG della gamba sinistra

Page 96: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

94

Introduzione

Simulatore SimJunior SimJunior supporta il training interattivo per procedure salvavita e risponde a interventi clinici, comandi di un istruttore e/o scenari pre-programmati, consentendo di esercitarsi in maniera efficace nella diagnosi e nel trattamento di un paziente.

Dotato di funzioni di respirazione spontanea, controllo delle vie aeree, voce, suoni, ECG e altre funzioni cliniche, SimJunior รจ un simulatore pediatrico altamente funzionale. SimJunior consente di osservare e rilevare la maggior parte dei segni vitali, permettendo all'istruttore di valutare le capacitร  dello studente nell'ambito di un quadro clinico realistico.

Caratteristiche di SimJunior

โ€“ Vie aeree realistiche per la simulazione della gestione di vie aeree problematiche e dell'intubazione orale e nasale.

โ€“ Respirazione osservabile.

โ€“ Caratteristiche cardiache, comprese defibrillazione e cardioversione.

โ€“ Occhi con pupille intercambiabili (normali, miotiche o midriatiche).

โ€“ Convulsioni per la simulazione di crisi epilettiche.

โ€“ Compressioni toraciche

โ€“ Accesso vascolare.

โ€“ Toni cardiaci, suoni respiratori e rumori intestinali normali e anomali.

โ€“ Controllo automatico della simulazione basato su scenari di pazienti pre-programmati e verificati.

รˆ possibile eseguire le simulazioni in modo autonomo mediante scenari su SimPad o in LLEAP (PC). Lo sviluppo delle condizioni del paziente sono pre-programmate e le reazioni automatiche in base agli interventi del partecipante.

Dimensioni globali

Lunghezza/Larghezza (solo simulatore): 120 cm x 42,5 cm Peso (solo simulatore): 11,36 kg

Indumenti di SimJunior

SimJunior include indumenti disegnati appositamente con aperture in velcro per una facile rimozione. Le istruzioni per il lavaggio sono riportate sulle etichette dei vestiti.

โ€“ Camicia

โ€“ Calzoncini corti

โ€“ Boxer

Caratteristiche cliniche generali Caratteristiche delle vie aeree

Le vie aeree sono anatomicamente corrette fino alla trachea. Le vie aeree consentono le seguenti manovre:

โ€“ Iperestensione del capo/sollevamento del mento

โ€“ Sublussazione della mandibola articolata.

โ€“ Manipolazione e pressione cricoidea

โ€“ Aspirazione (orale e nasofaringea)

Il simulatore puรฒ essere ventilato con metodi normali o d'emergenza:

โ€“ Pallone di ventilazione

โ€“ Intubazione orotracheale

โ€“ Intubazione nasotracheale

Prima di usare dispositivi per le vie aeree, lubrificarli applicando il lubrificante per vie aeree Laerdal.

I seguenti dispositivi o metodi sono sicuri quando si gestiscono le vie aeree del simulatore:

โ€“ Maschera laringea per vie aeree (misura n. 2,5).

โ€“ Intubazione con tubo endotracheale (misure diam. int. ร˜ 4,5 cuffiato, 5,5 non cuffiato).

Si consiglia di usare un mandrino flessibile. Verificare che non si estenda oltre il tubo ET.

Le seguenti condizioni del simulatore indicano che il tubo non รจ stato inserito correttamente:

โ€“ Intubazione del bronco principale destro - Sollevamento toracico unilaterale

โ€“ Distensione dello stomaco

โ€“ Assenza di suoni toracici (vedere la sezione Respirazione).

Il simulatore puรฒ essere configurato per presentare vari scenari relativi alle vie aeree:

โ€“ Edema della lingua - livelli normali, medi, massimi.

โ€“ Polmoni aperti o chiusi.

Caratteristiche respiratorie

SimJunior รจ in grado di simulare la respirazione spontanea con sollevamento e abbassamento del torace visibili e varie frequenze respiratorie. La respirazione viene generata da un compressore ad aria interno situato nella coscia destra del simulatore.

โ€“ Sollevamento e abbassamento toracico bilaterale con respirazione spontanea.

โ€“ Sollevamento e abbassamento toracico unilaterale con intubazione del bronco principale destro durante la ventilazione.

โ€“ Suoni polmonari unilaterali e bilaterali.

โ€“ Suoni respiratori normali e anomali

โ€“ Frequenza respiratoria variabile (0-60 respiri al minuto).

โ€“ Siti di auscultazione anteriori (4).

Il polmone sinistro e destro possono essere chiusi singolarmente o insieme creando unโ€™ostruzione parziale o completa delle vie aeree. Il simulatore SimJunior puรฒ anche essere usato con la ventilazione assistita.

Nota: i polmoni non supportano l'uso di valvole PEEP.

Page 97: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e di

si

mul

azio

ne

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e In

trod

uzio

ne

Ris

oluz

ione

dei

pr

oble

mi

95

Introduzione

Caratteristiche circolatorie

Cardiaco/a:

โ€“ Ampia raccolta di ECG, pulsazioni da 0 a 200.

โ€“ Suoni cardiaci - Posizione anteriore (1).

โ€“ Monitoraggio ritmo ECG (ECG a 4 connettori e 3 derivazioni)

โ€“ Display ECG a 12 derivazioni (solo con LLEAP).

โ€“ Pacing

โ€“ Defibrillazione e cardioversione mediante defibrillatori reali.

Defibrillazione:

โ€“ Il numero di scariche necessarie per la conversione automatica รจ impostato per ogni caso paziente simulato.

Perni per la defibrillazione

Perni ECG a 3 derivazioni

Pressione sanguigna e pulsazioni

โ€“ Pressione sanguigna misurata manualmente mediante auscultazione dei suoni di Korotkoff

โ€“ Pulsazioni carotidee bilaterali

โ€“ Le pulsazioni centrali possono essere impostate su normali, deboli o assenti.

โ€“ Le pulsazioni radiali/brachiali possono essere impostate su normali, deboli o assenti.

โ€“ Pulsazioni carotidee, brachiali e radiali sincronizzate con l'ECG.

โ€“ Forza delle pulsazioni variabile in base alla pressione sanguigna

โ€“ La palpazione del polso viene rilevata e registrata

Caratteristiche della RCP

โ€“ Conformitร  alle linee guida del 2010.

โ€“ Le compressioni generano pulsazioni palpabili, forma d'onda della pressione sanguigna e artefatti ECG

โ€“ Resistenza e profonditร  di compressione realistiche

โ€“ Rilevamento di profonditร  e frequenza delle compressioni.

Caratteristiche vascolari

Accesso EV:

L'accesso EV รจ possibile sul braccio e sulla mano destri. Il braccio per EV puรฒ essere impostato per l'inserimento, l'infusione e il bolo EV in:

โ€“ Vene periferiche dell'avambraccio.

โ€“ Fossa antecubitale e dorso della mano.

Accesso intraosseo (IO)

L'accesso per un'infusione IO รจ possibile in:

โ€“ Tuberositร  tibiale (destra)

โ€“ Malleolo mediale

Note: SimJunior non dispone di aree per iniezioni intramuscolari (IM). Non tentare di effettuare iniezioni IM.

Impostazioni del suono per SimJunior SimJunior supporta diverse aree per l'auscultazione e il rilevamento dei toni cardiaci, dei suoni respiratori e dei rumori intestinali. SimJunior consente anche di impostare suoni vocali.

Per ulteriori informazioni sull'impostazione dei sogni di SimJunior, fare riferimento alle Istruzioni per l'uso di SimPad o ai file della guida di LLEAP.

Page 98: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

96

Software di simulazione

PC dell'istruttore

Il PC dell'istruttore utilizza il software LLEAP per gestire le sessioni di simulazione. รˆ possibile accedere a LLEAP, come ad altre utili applicazioni correlate alla simulazione, attraverso Laerdal Simulation Home.

Licenza del software Il PC dell'istruttore viene fornito da Laerdal Medical con una licenza LLEAP preattivata installata.

Modifiche o aggiornamenti dell'hardware del computer (ad es. nuovo disco rigido o nuova scheda madre) potrebbero invalidare la licenza. Per supporto al fine di riattivare la licenza, rivolgersi all'assistenza clienti Laerdal locale.

Laerdal Simulation HomeIn Laerdal Simulation Home รจ possibile trovare e avviare LLEAP e altri programmi Laerdal relativi alla simulazione di paziente, nonchรฉ i file della guida. Laerdal Simulation Home si trova nella cartella Laerdal Medical sotto il menu Avvio (Start) di Windows (Windows 7).

Il software usato in una sessione di simulazione puรฒ essere suddiviso nelle seguenti applicazioni principali:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server o Session Viewer

SimDesigner e altre applicazioni sono inoltre usati per lo sviluppo o la preparazione di una simulazione.

LLEAPLLEAP (Laerdal Learning Application) รจ l'applicazione dell'istruttore da cui la sessione di simulazione รจ eseguita, controllata e monitorata. LLEAP puรฒ funzionare in modalitร  automatica o manuale. La modalitร  automatica รจ usata per gli scenari pre-programmati, mentre la modalitร  manuale garantisce all'istruttore il controllo manuale completo della sessione di simulazione. In genere, l'esecuzione delle simulazioni in modalitร  manuale richiede esperienza medica per la creazione di simulazioni cliniche verosimili.

Voice Conference Application (VCA)Il software Voice Conference Application รจ necessario per trasmettere tutti i suoni vocali utilizzati durante le simulazione. Questo software consente all'istruttore di comunicare attraverso il simulatore durante la sessione. La Voice Conference Application puรฒ anche essere utilizzata per comunicare con altri istruttori in rete e creare canali separati in cui solo i membri possono parlare e ascoltare.

Patient MonitorL'applicazione Patient Monitor simula un tipico monitor paziente da ospedale. Costituisce la console dell'allievo e puรฒ essere impostata e controllata dall'istruttore e dall'allievo mediante i menu touch screen.

Session Viewer e SimView ServerSession Viewer e SimView Server sono applicazioni che registrano video e acquisiscono immagini dallo schermo del monitor paziente durante la simulazione, oltre a fornire l'interfaccia per il debriefing della sessione. Al termine di una sessione, i file di registro generati in LLEAP vengono trasferiti e integrati ai file video di Session Viewer o SimView Server per il debriefing.

In genere, Session Viewer viene eseguito localmente sullo stesso computer utilizzato per LLEAP, mentre SimView Server viene eseguito su un server dedicato sulla rete locale. Durante il primo avvio di LLEAP, viene richiesto di selezionare un sistema di debriefing disponibile, sul computer o su una rete locale. Questa impostazione puรฒ essere modificata in un secondo momento.

Altre applicazioniEsistono altri programmi da usare in concomitanza con le sessioni di simulazione: ad esempio, License Manager per la gestione delle licenze del programma e Simulator Firmware & Network Wizard per l'aggiornamento del firmware dei simulatori o per la risoluzione dei problemi di rete.

SimDesignerSimDesigner รจ un'applicazione per la configurazione di scenari pre-programmati. Puรฒ, inoltre, essere usata per analizzare e stampare la rappresentazione grafica di uno scenario.

Si deve installare SimDesigner per consentire la conversione di file applicazione istruttore originati da versioni precedenti in formati file compatibili con LLEAP.

File della guida

Per ulteriori informazioni sul software LLEAP e altre applicazioni, consultare i file della guida.

1. In Windows fare clic su <Avvio> e quindi <Tutti i programmi>.

2. Selezionare <Laerdal Simulation Home>.

3. Selezionare <Guida>.

Download dal Web Visitare il sito Web www.laerdal.com/downloads per scaricare la versione piรน recente della Guida e del software.

Page 99: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

97

Softw

are

di

sim

ulaz

ione

In

trod

uzio

ne

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e R

isol

uzio

ne d

ei

prob

lem

i

Preparazione del simulatore

Preparazione alle simulazioni Dopo aver preparato il simulatore SimJunior e configurato tutti i dispositivi interattivi applicabili (SimPad, PC dell'istruttore o monitor paziente) perchรฉ siano pronti all'uso, potrebbero essere richiesti ulteriori preparativi prima di eseguire le simulazioni con SimJunior.

I preparativi finali per la simulazione includono:

โ€ข Preparazione della gamba per infusione intraossea

โ€ข Somministrazione di fluidi via EV

โ€ข Drenaggio dei fluidi per EV in eccesso

โ€ข Pulizia del braccio per EV

โ€ข Connessione di piastre adattate per la defibrillazione

โ€ข Collegamento del bracciale per la misurazione della pressione sanguigna

โ€ข Sostituzione delle pupille

โ€ข Connessione di un compressore esterno

โ€ข Modifica delle impostazioni per il compressore interno

Preparazione della gamba per infusione intraossea La gamba destra del simulatore รจ progettata per praticare infusioni intraossee. L'anatomia della gamba destra include il ginocchio, la tibia, la tuberositร  tibiale e il malleolo mediale. La gamba destra include i cateteri e una sacca per EV da usare come serbatoio durante l'infusione.

Accessori aggiuntivi richiesti

โ€ข Sacca e set per la somministrazione EV.

โ€ข Concentrato ematico finto.

โ€ข Siringa da 35 cc e ago intraosseo da 16 G.

Per riempire la gamba per infusione intraossea e prepararla all'uso

1. Sollevare la gamba in posizione verticale.

2. Aprire il tappo situato sul tallone.

3. Con una siringa iniettare nelle ossa circa 240-250 cc di sangue finto.

4. Fissare i tubi collegati alla sacca di raccolta per EV (usare un fermo a rotella per aprire o chiudere il catetere secondo necessitร , al fine di impedire un aumento eccessivo della pressione).

5. Chiudere il tubo che porta alla sacca di raccolta in modo che il sangue finto permanga nell'osso per l'aspirazione.

6. Quando la sacca di raccolta รจ piena, interrompere l'infusione e sostituirla con una vuota.

Prima di riporre il simulatore

โ€“ Staccare il catetere EV e il serbatoio dal piede.

โ€“ Lasciare drenare tutto il fluido.

โ€“ Riporre la gamba senza tappo per permettere che si asciughi all'aria.

Nota: non usare soluzioni saline, in quanto potrebbero causare il deterioramento della gamba. Usare acqua distillata o deionizzata per evitare un accumulo di minerali.

Somministrazione di fluidi via EV Il braccio destro per EV consente di praticare somministrazione EV di farmaci, inserimento di un catetere EV, flebo e bolo nelle vene periferiche dell'avambraccio, della fossa antecubitale e del dorso della mano.

Per la simulazione EV, usare aghi da 20-22 G. Per evitare ostruzioni nel sistema EV, usare esclusivamente acqua distillata o deionizzata per simulare farmaci somministrati via EV.

Page 100: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

98

Preparazione del simulatore

Drenaggio dei fluidi per EV in eccesso Il sistema dei fluidi per EV รจ aperto. I fluidi EV vengono drenati nel corso della somministrazione.

Prima di ogni sessione

1. Collegare il tubo di traboccamento EV (nel braccio destro del simulatore) a un contenitore di raccolta (ad esempio, una sacca EV).

2. Lasciare che il fluido in eccesso scorra in un contenitore durante la simulazione.

Pulizia del braccio per EV Pulire il braccio per EV dopo ogni sessione o al termine della giornata, sciacquandolo con alcol isopropilico al 60% o etanolo al 70%.

Installazione delle piastre adattatore per defibrillazione Il tronco del simulatore รจ dotato di due perni di connessione per i cavi del defibrillatore. Prima di applicare la defibrillazione, occorre svitare e rimuovere i perni del defibrillatore.

Le piastre adattatore per defibrillazione devono essere posizionate correttamente prima di usare un defibrillatore reale con piastre di defibrillazione. Avvitare saldamente queste piastre in posizione.

Durante la defibrillazione Su SimJunior รจ possibile usare un normale defibrillatore (non incluso). Durante la defibrillazione, il defibrillatore e il simulatore possono presentare il pericolo di scosse elettriche. Quando si usa il defibrillatore sul simulatore, occorre adottare tutte le precauzioni di sicurezza standard.

Attenzione: durante la defibrillazione il simulatore non deve entrare in contatto con oggetti o superfici conduttive.

Avvertenze

โ€“ La defibrillazione deve essere eseguita esclusivamente con gli appositi connettori.

โ€“ Non defibrillare il simulatore se la pelle del tronco non รจ al posto giusto.

Collegamento del bracciale per la misurazione della pressione sanguigna

Il simulatore viene fornito con un bracciale personalizzato per la misurazione della pressione sanguigna. Collegare il tubo al connettore bianco per la misurazione della pressione sanguigna dietro alla Link Box prima dell'uso.

Nota: l'altoparlante per la pressione sanguigna del simulatore รจ situato nella fossa antecubitale sinistra, nella posizione indicata in figura da un cerchio. Le pulsazioni radiali e brachiali sono invece situate nelle aree indicate dai rettangoli.

Calibratura del bracciale per la misurazione della pressione sanguigna in LLEAP

1. Selezionare <Strumenti> dal menu

2. Selezionare <Preparazione del simulatore> dal menu Strumenti

3. Selezionare <Calibra pressione sanguina> dal sottomenu

4. Per effettuare la calibrazione seguire le istruzioni visualizzate della procedura guidata

Calibratura del bracciale per la misurazione della pressione sanguigna in SimPad

1. Selezionare <Calibratura> nel menu.

2. Selezionare <Calibra pressione sanguigna> nel sottomenu.

3. Per effettuare la calibrazione, seguire le istruzioni visualizzate della procedura guidata.

Page 101: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

99

Prep

araz

ione

del

si

mul

ator

e In

trod

uzio

ne

Man

uten

zion

e Pa

rti d

i ric

ambi

o e

acce

ssor

i Sp

ecifi

che

Ris

oluz

ione

dei

pr

oble

mi

So

ftw

are

di

sim

ulaz

ione

Preparazione del simulatore

Sostituzione delle pupille

SimJunior viene fornito con pupille normali inserite negli occhi. Con SimJunior viene inoltre fornito un kit separato contenente un set di pupille di plastica (miotiche e midriatiche).

Per sostituire le pupille:

1. Aprire con cautela le palpebre, facendo attenzione a non strappare la pelle del viso del simulatore.

2. Rimuovere la pupilla dall'occhio con cautela usando la ventosa in dotazione con il kit o la punta delle unghie.

3. Sostituire la pupilla inserendo quella desiderata usando la ventosa o premendola delicatamente in posizione.

Uso di un compressore esterno Il compressore esterno รจ collegato al tubo trasparente situato tra i cavi che escono dal lato destro del simulatore. Quando si utilizza un compressore esterno รจ possibile spegnere il compressore interno tramite SimPad o LLEAP.

Per ulteriori informazioni sui compressori esterni e sui pannelli di regolazione compatibili con SimJunior, rivolgersi al rappresentante Laerdal locale.

Accensione o spegnimento del compressore interno in SimPad

1. Avviare la <Modalitร  manuale>, selezionare un tema e avviare la sessione.

2. Selezionare <Varie> dal menu.

3. Selezionare <Compressore> dal sottomenu.

4. Effettuare le modifiche desiderate nella finestra di dialogo e fare clic su OK.

Accensione o spegnimento del compressore interno in LLEAP

1. Selezionare <Strumenti> dal menu.

2. Selezionare <Preparazione del simulatore> dal menu Tools Strumenti.

3. Selezionare <Compressore interno> dal sottomenu.

4. Effettuare le modifiche desiderate nella finestra di dialogo e fare clic su OK.

Page 102: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

100

Nota: per informazioni su accessori e parti di ricambio, consultare la sezione Parti di ricambio e accessori.

Prima di riporre o spedire

โ€“ Sciacquare il braccio per EV con alcol isopropilico al 60% o etanolo al 70%. Aprire la valvola di drenaggio in fondo al piede destro del simulatore.

Manutenzione

Manutenzione dopo ogni sessione di simulazione Le seguenti misure preventive sono necessarie per assicurare una lunga durata del simulatore SimJunior.

โ€“ Spegnere SimPad, Link Box e PC.

โ€“ Caricare le batterie, se necessario.

โ€“ Sciacquare il sistema del braccio per EV e drenare la gamba per infusione intraossea (lasciando aperto il tappo in fondo alla gamba).

โ€“ Dopo ogni sessione in cui si usa il braccio per EV, sciacquarlo con alcol isopropilico al 60% o etanolo al 70%.

โ€“ Asciugare la pelle con un panno umido.

โ€“ Rimuovere indumenti o teli bagnati.

โ€“ Rimuovere i residui di adesivo con un panno umido o alcol disinfettante.

โ€“ In base all'uso del simulatore, sostituire i moduli usurati o danneggiati.

โ€“ Sostituire i cavi o i connettori visibilmente danneggiati.

โ€“ La manutenzione deve essere effettuata da personale qualificato a intervalli regolari.

Effettuare sempre la manutenzione:

โ€“ Se sono stati versati dei liquidi dentro o sopra il simulatore

โ€“ Dopo l'uso in ambienti polverosi

Page 103: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

101

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

In

trod

uzio

ne

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e R

isol

uzio

ne d

ei

prob

lem

i

Soft

war

e di

si

mul

azio

ne

Manutenzione

Apertura del tronco

Aprire il tronco del simulatore per eseguire procedure quali

โ€“ Fissaggio o sostituzione di arti

โ€“ Sostituzione della batteria del simulatore

โ€“ Sostituzione della camera d'aria per il sollevamento del torace e dei polmoni

โ€“ Sostituzione della pelle del tronco

โ€“ Ai fini di un'ispezione generale

Avvertenza: aprire il tronco da sinistra a destra, sganciando con cautela la pelle. Non tirare con forza quando si solleva la pelle del simulatore perchรฉ si potrebbero danneggiare i cavi del torace.

1. Rimuovere i ganci che fissano la pelle sul lato sinistro del tronco e su ciascuna spalla.

Sostituzione della batteria del simulatore

1. Aprire il tronco del simulatore.

2. Ripiegare la pelle del tronco sul lato destro.

3. Scollegare il cavo del connettore per la defibrillazione.

4. Il cavo del connettore per la defibrillazione deve essere scollegato sul lato destro del simulatore, sotto il modulo di materiale espanso del torace.

Nota: NON scollegare tubi e cavi connessi al modulo di materiale espanso dello stomaco del simulatore.

5. Riposizionare la pelle del tronco ripetendo i passaggi 1-4 in ordine inverso.

2. Estrarre la batteria dalla cinghia di fissaggio.

3. Estrarre il cavo di alimentazione della batteria dall'interno del simulatore. Sganciare il cavo di alimentazione della batteria.

4. Rimuovere la batteria dal simulatore.

5. Sostituire con una batteria carica o installare una nuova batteria per SimJunior approvata da Laerdal.

6. Collegare la batteria al simulatore.

7. Sostituire la pelle del tronco.

Page 104: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

102

Manutenzione

Ricarica della batteria del simulatore

La batteria del simulatore si ricarica automaticamente durante l'uso. Se necessario, puรฒ essere caricata anche usando un adattatore di corrente esterno opzionale.

1. Spegnere il simulatore mediante la Link Box.

2. Rimuovere la batteria dal simulatore.

3. Collegare un carica-batterie esterno approvato (con cavo elettrico conforme alle specifiche locali) sotto la batteria del simulatore. Collegare il cavo di alimentazione del carica-batterie a una presa a muro.

4. Al termine della ricarica, riposizionare la batteria nel simulatore.

Sostituzione della camera d'aria per il sollevamento del torace La camera d'aria per il sollevamento del torace si trova nella parte inferiore della piastra toracica, sotto i polmoni, al centro.

1. Aprire la pelle del tronco per esporre la piastra toracica. Vedere Apertura del tronco.

2. Scollegare il tubo trasparente dalla camera d'aria dei polmoni prima di rimuoverla. Per ulteriori dettagli, vedere la sezione Sostituzione della camera d'aria dei polmoni

3. Scollegare il tubo trasparente dalla camera d'aria per il sollevamento del torace.

4. Eliminare la vecchia camera d'aria.

5. Inserire la nuova camera d'aria.

6. Ricollegare i tubi alla nuova camera d'aria.

7. Chiudere il tronco e riposizionare la pelle del tronco.

Sostituzione della camera d'aria dei polmoni In caso di perdite di liquidi รจ necessario sostituire la camera d'aria dei polmoni (all'interno della cavitร  toracica).

1. Aprire la pelle del tronco.

2. Scollegare i tubi trasparenti da sotto ciascun lato della camera d'aria polmonare. Fare riferimento alla figura del secondo passaggio nella sezione Sostituzione della camera d'aria per il sollevamento del torace.

3. Scollegare il gancio dalla parte centrale superiore della camera d'aria dei polmoni.

4. Sollevare con cautela la porzione centrale superiore della camera d'aria dei polmoni dal suo alloggiamento.

5. Eseguire la procedura all'inverso per installare la nuova camera d'aria dei polmoni.

Page 105: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

103

Prep

araz

ione

del

si

mul

ator

e M

anut

enzi

one

In

trod

uzio

ne

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e R

isol

uzio

ne d

ei

prob

lem

i

Soft

war

e di

si

mul

azio

ne

Sostituzione delle pelli del simulatore Potrebbe essere necessario sostituire porzioni della pelle del simulatore strappate, perforate o macchiate.

Pelle del tronco

Per sostituire la pelle del tronco del simulatore, consultare la sezione Apertura del tronco.

Pelle del braccio

Per sostituire la pelle del braccio del simulatore, eseguire quanto descritto di seguito.

1. Rimuovere la pelle del braccio del simulatore facendola scivolare verso il basso attorno al braccio e alla mano oppure *tagliare la pelle.

Per attaccare il nuovo braccio, eseguire quanto de-scritto di seguito.

Manutenzione

Sostituzione del braccio destro per EV

1. Aprire il tronco come descritto nella sezione Apertura del tronco.

2. Rimuovere il braccio presente svitando il bullone che lo fissa alla spalla del simulatore.

3. Verificare che la vite della spalla sia sufficientemente allentata da permettere all'asse del braccio di scivolare fuori agevolmente.

4. Eliminare il vecchio braccio in conformitร  con le linee guida specifiche.

1. Verificare che la vite della spalla sia sufficientemente allentata per permettere all'asse del braccio di scivolare agevolmente in posizione.

2. Collegare il braccio ai punti di connessione corrispondenti nel tronco.

3. Spingere con cautela l'assale del braccio dentro il supporto della spalla, in modo che si trovi a filo con l'interno del supporto.

4. Fissare la vite della spalla con una brugola.

Sostituzione della gamba destra per infusione intraossea Per staccare la parte inferiore della gamba destra -

1. Verificare che tutti i liquidi all'interno della gamba siano stati drenati.

2. Rimuovere la gamba per infusione intraossea svitando il bullone che la fissa alla coscia.

3. Far scivolare la parte bassa della gamba per infusione intraossea fuori dalla coscia.

4. Eliminare la vecchia gamba per infusione intraossea in conformitร  con le linee guida specifiche.

Ripetere la precedente procedura all'inverso per attaccare la nuova gamba per infusione intraossea.

Avvertenza: *prestare attenzione a non perforare o tagliare l'anima del braccio.

2. Eliminare la vecchia pelle.

3. Lubrificare l'interno della nuova pelle del braccio con liquido detergente delicato misto ad acqua.

4. Lubrificare (o insaponare) l'anima del braccio con un misto di liquido detergente delicato e acqua.

5. Inserire la mano del simulatore nella pelle.

6. Calzare la pelle sulle dita, come si fa con un guanto.

7. Stendere la pelle sull'anima del braccio, srotolandola verso l'alto.

Page 106: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

104

Risoluzione dei problemi

Impostazione del sistema

Problema

โ€ข Dati smarriti o guasto dell'intero sistema (General System failure).

Soluzione possibile

โ€ข Se l'intero sistema si blocca oppure vengono persi o danneggiati tutti i dati, contattare il centro di assistenza Laerdal locale.

LLEAPโ€ข Vedere File della guida per il software > LLEAP > Guida alla

risoluzione dei problemi (la guida รจ accessibile in Laerdal Simulation Home).

Laerdal Patient Monitorโ€ข Vedere File della guida per il software > Laerdal Patient Monitor

> Guida alla risoluzione dei problemi (la guida รจ accessibile in Laerdal Simulation Home).

Debriefing e registrazione videoโ€ข Vedere la sezione della risoluzione dei problemi nella guida di

SimView (accessibile da un collegamento in fondo la schermata di SimView) o la Guida alla risoluzione dei problemi dalla guida di SessionViewer (accessibile in Laerdal Simulation Home).

Simulatore

Problema

โ€ข Comportamento imprevedibile.

Soluzioni possibili

โ€ข I guasti del simulatore potrebbero essere causati da cavi, tubi o connettori allentati. Aprire il tronco e verificare se sono presenti componenti scollegati o con perdite. Consultare la sezione: Preparazione del simulatore - Apertura del tronco.

โ€ข In presenza di perdite di liquidi, spegnere il simulatore e contattare l'assistenza tecnica Laerdal.

Contaminazione delle vie aeree

Problema

โ€ข Le vie aeree del simulatore paziente sono state contaminate da una procedura di respirazione d'emergenza bocca a bocca.

Soluzione possibile

โ€ข Pulire l'esterno del simulatore con le salviette per simulatore. Pulire l'interno della cavitร  orale con le salviette per simulatore. Sostituzione delle camere d'aria dei polmoni, vedere: Manutenzione - Sostituzione delle camere d'aria dei polmoni.

Movimento del torace

Problema

โ€ข Il torace del simulatore non si solleva.

Soluzioni possibili

โ€ข Verificare che il simulatore sia acceso.

โ€ข In SimPad o LLEAP, accertarsi che โ€“ la frequenza respiratoria delle vie aeree (awRR) non sia

impostata su zero

โ€“ Il sollevamento del torace non sia spento

โ€“ Il valore ECG sia impostato su un ritmo di perfusione

โ€“ Non siano impostate complicazioni delle vie aeree, quali resistenza massima dell'aria o laringospasmo

โ€“ Verificare che il compressore integrato sia attivato in LLEAP. Consultare la sezione: spegnimento del compressore interno

โ€ข Verificare che tutte le fonti esterne di aria compressa siano spente e che il tubo dell'aria sia scollegato dal simulatore.

โ€ข Il compressore interno potrebbe essersi surriscaldato. Attendere circa 20 minuti per farlo raffreddare.

โ€ข Il sollevamento toracico รจ impostato su bilaterale (ad esempio se il tubo ET รจ inserito troppo in profonditร  nei bronchi).

โ€ข La camera d'aria per il sollevamento del torace ha una perdita oppure i tubi della camera d'aria sono attorcigliati, piegati o scollegati. In caso di perdita sostituire la camera d'aria per il sollevamento del torace, vedere Manutenzione - Sostituzione della camera d'aria per il sollevamento del torace.

โ€ข Verificare se i tubi presentano perdite e che le connessioni siano intatte. Sostituire la sezione del tubo interessata in presenza di una perdita.

โ€ข Movimenti toracici superficiali e compressore interno sempre in funzione. Il compressore interno potrebbe essere usurato. Contattare l'assistenza tecnica Laerdal.

Polmoni

Problema

โ€ข I polmoni non funzionano correttamente

Soluzioni possibili

โ€ข Aprire il tronco e la piastra toracica. Verificare che i polmoni siano liberi di espandersi e che non siano vincolati a qualche cavo.

Page 107: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

105

Man

uten

zion

e

Ris

oluz

ione

dei

pr

oble

mi

Prep

araz

ione

del

si

mul

ator

e In

trod

uzio

ne

Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e So

ftw

are

di

sim

ulaz

ione

Risoluzione dei problemi

โ€ข Verficare che la camera d'aria dei polmoni sia collegata correttamente e che i tubi non siano attorcigliati.

โ€ข Verificare che la camera d'aria dei polmoni si trovi in posizione orizzontale e che sia inserita correttamente.

โ€ข Verificare che non siano presenti perdite o strappi nella camera d'aria dei polmoni.

โ€ข Controllare che non siano presenti ostruzioni nelle vie aeree del simulatore paziente che potrebbero bloccare il flusso d'aria.

โ€ข Se, dopo aver regolato la complianza polmonare, non si riscontra alcun cambiamento, contattare l'assistenza tecnica Laerdal.

โ€ข Se non si riscontra alcun cambiamento nella resistenza polmonare, contattare l'assistenza tecnica Laerdal.

Rumori meccanici durante l'auscultazioneFare clic su <Focolaio di auscultazione> in LLEAP.

Pulsazioni (radiali e brachiali)

Problema

โ€ข Impossibile sentire le pulsazioni.

Soluzioni possibili

โ€ข La pelle sui moduli dei polsi potrebbe essere troppo tesa: riposizionare la pelle e riavviare il sistema.

โ€ข Verificare che la pressione sistolica sia impostata almeno su 60.

โ€ข Verificare che il compressore sia acceso.

Nota: se le pulsazioni radiali sono impostate su un valore inferiore a 60, le pulsazioni periferiche potrebbero scomparire.

Arresto del simulatore

Problema

โ€ข Il simulatore non reagisce.

Soluzione

1. Spegnere la Link Box.

2. Spegnere SimPad o, se si sta utilizzando LLEAP, spegnere il PC dell'istruttore.

3. Riavviare tutti i sistemi.

Se il simulatore continua ad essere non reattivo, contattare il rappresentante Laerdal locale.

Page 108: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

106

Note

Page 109: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

107

Spec

ifich

e R

isol

uzio

ne d

ei

prob

lem

i M

anut

enzi

one

Pr

epar

azio

ne d

el

sim

ulat

ore

Intr

oduz

ione

Pa

rti d

i ric

ambi

o e

acce

ssor

i So

ftw

are

di

sim

ulaz

ione

Specifiche

Dimensioni globali Lunghezza/Larghezza (solo simulatore): 120 x 42,5 cm Peso (solo simulatore): 11,36 kg

Tipo di alimentazione del simulatore Alimentazione esterna: Tensione in ingresso 9 V CC, 1,5 A Batteria interna: 7,4 V, 4,4 Ah, ioni di litio

Usare esclusivamente batterie e alimentatori esterni approvati per SimJunior.

Pressione dell'aria Serbatoio interno dell'aria: massimo 6 psi Connessione aria esterna: massimo 16 psi

Limiti di temperatura Temperature di esercizio: da 4 ยบC a 40 ยบC Temperature di conservazione: da -15 ยบC a 50 ยบC

Ambiente - Solo simulatore Umiditร  relativa: 20%-90% (senza condensa) NON usare all'esterno in condizioni di elevata umiditร . Non testato con spray al sale.

Comunicazioni RF Portata operativa: massimo 10 m

Elenco materiali del simulatore Indumenti: cotone, nylon Pelle e vie aeree: PVC Parti esterne in plastica dura: PVC, ABS Parti interne in plastica: silicone, TPU, PVC, nitrile ABS, POM, nylon + fibra di vetro epossipoliuretano Componenti in metallo: alluminio, ottone, acciaio

Requisiti minimi del computer

โ€ข Processore Intel i-core terza generazione o successiva

โ€ข Punteggio oltre 3000 PassMark - Punteggio CPU

โ€ข 4 GB di RAM

โ€ข 120 GB di spazio sul disco rigido

โ€ข 1366 x 768 o superiore

โ€ข Cuffia con microfono

โ€ข 2 porte USB

Requisiti software minimi

โ€ข Windows 7 o Windows 8

โ€ข 100% DPI

Liquidi per la pulizia Per pulire il simulatore usare uno dei seguenti liquidi:

โ€“ Alcol isopropilico al 60%

โ€“ Etanolo al 70%

โ€“ Soluzione delicata di detergente liquido e acqua

Fluidi per EV Per simulare fluidi per endovenosa e infusione intraossea, usare solo acqua distillata o deionizzata.

Page 110: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

108

Note

Page 111: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

109 Part

i di r

icam

bio

e ac

cess

ori

Spec

ifich

e

Ris

oluz

ione

dei

pr

oble

mi

Man

uten

zion

e

Prep

araz

ione

del

si

mul

ator

e In

trod

uzio

ne

Soft

war

e di

si

mul

azio

ne

Parti di ricambio e accessori

Parti di ricambio e accessori Per le versioni piรน recenti delle Parti di ricambio e accessori, visitare la pagina Web www.laerdal.com.

Page 112: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

110

Note

Page 113: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

111

Manutenรงรฃo 122

โ€“ Manutenรงรฃo apรณs cada sessรฃo de simulaรงรฃo 122 โ€“ Abertura do torso 123 โ€“ Substituiรงรฃo da bateria do simulador 123 โ€“ Carregamento da bateria do simulador 124 โ€“ Substituiรงรฃo do balรฃo para elevaรงรฃo torรกcica 124 โ€“ Substituiรงรฃo do balรฃo para pulmรฃo 124 โ€“ Substituiรงรฃo das peles do simulador 125 โ€“ Substituiรงรฃo do braรงo direito para EV 125 โ€“ Substituiรงรฃo da perna IO direita 125

Soluรงรฃo de problemas 126

Introduรงรฃo 112

โ€“ Informaรงรตes regulatรณrias 112 โ€“ Cuidados gerais com o simulador 113โ€“ Imagem de visรฃo geral do SimJunior 115 โ€“ Recursos do SimJunior 116

Configuraรงรฃo do simulador 119

โ€“ Preparaรงรฃo para simulaรงรตes 119 โ€“ Preparaรงรฃo da perna IO 119 โ€“ Administraรงรฃo de fluidos EV 119 โ€“ Drenagem de excesso de fluido EV 120 โ€“ Limpeza do braรงo para EV 120 โ€“ Instalaรงรฃo das placas do adaptador de desfibrilaรงรฃo 120 โ€“ Conexรฃo do manguito de pressรฃo arterial 120 โ€“ Calibraรงรฃo do manguito de pressรฃo arterial no LLEAP 120 โ€“ Calibraรงรฃo do manguito de pressรฃo arterial no SimPad 120โ€“ Troca de pupilas 121 โ€“ Uso do compressor externo 121

Especificaรงรตes 129

Software de simulaรงรฃo 118

โ€“ PC do instrutor 118 โ€“ Licenรงa de software 118 โ€“ Laerdal Simulation Home 118โ€“ LLEAP 118โ€“ Voice Conference Application 118โ€“ Patient Monitor 118โ€“ Session Viewer e SimView Server 118โ€“ Outros aplicativos 118โ€“ SimDesigner 118โ€“ Arquivos de ajuda 118โ€“ Downloads da web 118

Acessรณrios e peรงas sobressalentes 131

Sumรกrio BR

Page 114: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

112

Li-ion

Introduรงรฃo

Apresentaรงรฃo do simulador SimJuniorโ„ข O SimJunior รฉ um simulador de paciente pediรกtrico realista, de tamanho real, desenvolvido pela Laerdal em colaboraรงรฃo com a American Academy of Pediatrics (Academia Americana de Pediatria). O SimJunior pode ser usado para o treinamento de pessoas ou equipes de profissionais da saรบde de vรกrias disciplinas clรญnicas.

O simulador SimJunior รฉ fornecido completamente montado. Nรฃo hรก necessidade de montar as peรงas do simulador.

Para saber detalhes sobre como preparar o SimJunior para simulaรงรฃo, consulte a seรงรฃo โ€œConfiguraรงรฃo do simuladorโ€.

Ajuda do SimJunior Instruรงรตes de uso

Instruรงรตes passo a passo e ilustraรงรตes para o uso do simulador SimJunior.

Manuais originais do fabricante

Todos os manuais do usuรกrio e etiquetas originais dos fabricantes devem ser seguidos. As Instruรงรตes de uso do SimJunior nรฃo substituem nem prevalecem sobre as instruรงรตes originais do fabricante.

Guia de configuraรงรฃo rรกpida do SimJunior

Guia passo a passo para configuraรงรฃo do sistema de simulaรงรฃo SimJunior.

Instruรงรตes de uso do SimPad

As Instruรงรตes de uso do SimPad fornecem instruรงรตes para o uso do Link Box e do SimPad com o SimJunior.

Arquivos de ajuda do LLEAP (Laerdal Learning Application)

Os arquivos de ajuda do LLEAP podem ser acessados pelo Laerdal Simulation Home; consulte a seรงรฃo Laerdal Simulation Home.

Os tรณpicos de ajuda incluem:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

Assistรชncia Tรฉcnica

Para obter assistรชncia tรฉcnica, entre em contato com o centro local de Serviรงo Tรฉcnico da Laerdal.

Downloads da web

Visite www.laerdal.com/downloads para fazer o download das instruรงรตes de uso e das versรตes do software de simulaรงรฃo mais recentes.

Conteรบdo do SimCenter O SimCenter oferece acesso fรกcil a conteรบdo validado de especialistas em simulaรงรฃo de todo o mundo, para que vocรช possa aproveitar sua experiรชncia e tirar o mรกximo de cada oportunidade de aprendizagem. Vocรช encontrarรก uma grande variedade de cenรกrios que foram desenvolvidos especificamente para o SimJunior. Visite www.mysimcenter.com para saber como vocรช pode otimizar ao mรกximo sua experiรชncia de aprendizagem.

Informaรงรตes regulatรณrias Federal Communications Commission Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Cuidado Alteraรงรตes ou modificaรงรตes nรฃo aprovadas expressamente pela parte responsรกvel pela conformidade podem anular a autoridade do usuรกrio para operar o equipamento.

Baterias de รญon-lรญtio devem ser recicladas.

A Laerdal Medical AS declara que, tendo a marca CE, este produto estรก em conformidade com os requisitos essenciais e outras disposiรงรตes relevantes da Diretiva 1999/5/EC.

O descarte deve ser feito de acordo com os requisitos e regulamentaรงรตes locais.

Page 115: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

113

Isenรงรฃo de responsabilidade O uso do sistema de simulaรงรฃo de paciente SimJunior para treinamento de pessoal deve ser realizado sob a supervisรฃo de uma equipe tรฉcnica ou mรฉdica adequadamente treinada, com entendimento dos princรญpios educativos, bem como dos protocolos mรฉdicos. Assim como ocorre com todos os simuladores ou outros dispositivos de treinamento, pode haver aproximaรงรตes, variaรงรตes e imprecisรตes relacionadas ร s caracterรญsticas anatรดmicas e aos modelos fisiolรณgicos. Por isso, a Laerdal nรฃo garante que todas as caracterรญsticas sejam completamente precisas.

Garantia global Consulte o livreto de Garantia global da Laerdal ou www.laerdal.com.

Paรญs de origem - O SimJunior รฉ fabricado nos Estados Unidos.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Introduรงรฃo

Cuidados gerais com o simulador Siga estas instruรงรตes para manter o desempenho otimizado e a longevidade do simulador e de seus componentes.

Cuidados gerais

Para preservar as peles do simulador, lave as mรฃos antes do uso e coloque o simulador sobre uma superfรญcie limpa. A Laerdal recomenda o seguinte:

โ€“ Use luvas durante os cenรกrios de simulaรงรฃo. Evite usar luvas plรกsticas coloridas, pois elas podem causar manchas na pele do simulador.

โ€“ Nรฃo use canetas esferogrรกficas nem hidrocores, acetona, iodo ou outros medicamentos que causem manchas prรณximo ao simulador. Tenha cuidado para nรฃo colocar o simulador sobre jornal ou papel colorido. As manchas podem ser permanentes.

โ€“ Limpe as peles do simulador com sabรฃo neutro e รกgua.

Nรฃo tente realizar as seguintes tรฉcnicas neste simulador, devido ร  incapacidade de higienizar as vias aรฉreas adequadamente:

โ€“ Ventilaรงรฃo boca-a-boca/boca-a-mรกscara

โ€“ Inserรงรฃo de vรดmito simulado ou fluidos para sucรงรฃo

โ€“ Se uma sessรฃo de treinamento envolver o uso de fluidos no braรงo para EV, drene o braรงo imediatamente apรณs a sessรฃo.

โ€“ Use somente Lubrificante de vias aรฉreas da Laerdal e aplique com moderaรงรฃo.

โ€“ Enxรกgue, limpe e seque os mรณdulos de componente do simulador.

โ€“ Dobre a pele do torso para trรกs e aplique talco na parte interna da pele, para reduzir o atrito. Nรฃo deixe cair talco na cavidade torรกcica do simulador.

Ambiente Em condiรงรตes de frio, aguarde o simulador atingir a temperatura ambiente antes de inicializรก-lo.

Para evitar o superaquecimento e reduzir o desgaste:

โ€“ Se for usar o simulador em temperaturas acima de 40ยฐC (104ยฐF), sempre deixe que ele esfrie entre as sessรตes de treinamento.

โ€“ Se for usar o simulador em uma cama, ele nรฃo deverรก ser coberto com roupa de cama pesada, que impeรงa a transferรชncia de calor.

Manuseio geral do simulador Tome as seguintes precauรงรตes para evitar ferimentos ou danos ao produto:

โ€“ Introduza fluidos no simulador somente conforme orientado neste documento.

โ€“ Lubrifique as vias aรฉreas orais e nasais com o lubrificante fornecido, antes de inserir qualquer instrumento, tubo ou dispositivo para as vias aรฉreas. Alรฉm disso, lubrifique os instrumentos e tubos antes de usรก-los.

โ€“ Nรฃo introduza ar umidificado no sistema durante a ventilaรงรฃo

โ€“ Nรฃo use o simulador se os tubos e cabos internos estiverem desconectados.

โ€“ Nunca utilize o simulador SimJunior ao ar livre, em condiรงรตes com presenรงa de รกgua, pois isso pode representar um risco de choque ou dano ao simulador.

โ€“ Usar um desfibrilador em temperaturas acima de 35ยฐC (95ยฐF) pode causar o superaquecimento do sistema.

Advertรชncia: Nรฃo use mรกquinas automรกticas de compressรฃo torรกcica no simulador.

Cuidado, lรกtex: Este produto contรฉm lรกtex de borracha natural, que pode causar reaรงรตes alรฉrgicas em contato com tecidos humanos.

Riscos da desfibrilaรงรฃo O SimJunior aceita desfibrilaรงรฃo.

Um desfibrilador convencional pode ser usado no SimJunior. Durante a desfibrilaรงรฃo, o desfibrilador e o simulador podem apresentar risco de choque. Todas as precauรงรตes de seguranรงa padrรฃo devem ser adotadas durante o uso do desfibrilador em um simulador.

โ€ข Leia e siga todas as instruรงรตes de seguranรงa e operaรงรฃo fornecidas com o desfibrilador e o equipamento associado.

โ€ข Siga o protocolo de desfibrilaรงรฃo, evitando o contato entre as pรกs externas e qualquer ponto de eletrodo durante a desfibrilaรงรฃo. Uma carga de atรฉ 300 joules pode ser aplicada.

โ€ข A nรฃo observaรงรฃo destas medidas de seguranรงa pode resultar em ferimento ou morte.

Para obter mais informaรงรตes, consulte o manual do usuรกrio original do desfibrilador.

Advertรชncias:

โ€“ Ao desfibrilar, use os conectores do desfibrilador ou a placa intercambiรกvel montada no tรณrax do simulador. Nรฃo use os conectores de ECG, projetados exclusivamente para monitoramento por ECG. A desfibrilaรงรฃo com os conectores de ECG danificarรก as partes eletrรดnicas internas do simulador e poderรก provocar ferimentos.

โ€“ Nรฃo desfibrile o simulador quando ele estiver DESLIGADO ou se nรฃo estiver funcionando normalmente.

Page 116: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

114

Introduรงรฃo

Para evitar o superaquecimento durante a desfibrilaรงรฃo, nรฃo exceda uma sequรชncia de desfibrilaรงรฃo de 3 choques em 45 segundos seguida de 1 minuto de RCP. Apรณs 30 minutos, interrompa a aplicaรงรฃo de choque por pelo menos 15 minutos antes de iniciar uma nova sequรชncia. Nรฃo repita isso por um perรญodo de mais de 4 horas. Alรฉm disso, nรฃo aplique mais de 2 descargas de 300 joules por minuto.

Advertรชncias:

โ€“ O simulador nรฃo deve entrar em contato com superfรญcies ou objetos condutores de eletricidade durante a desfibrilaรงรฃo.

โ€“ Evite o uso em todos os ambientes inflamรกveis. Por exemplo, altos nรญveis de oxigรชnio puro devem ser evitados durante a desfibrilaรงรฃo. Garanta que haja uma boa ventilaรงรฃo, caso seja usado oxigรชnio concentrado prรณximo ao simulador.

โ€“ O torso do simulador deve estar sempre seco. โ€“ Deixe o simulador se aclimatar antes da desfibrilaรงรฃo. Mudanรงas

sรบbitas de temperatura podem resultar no acรบmulo de condensaรงรฃo em componentes eletrรดnicos, podendo representar um risco de choque.

โ€“ Para evitar que o eletrodo marque a pele do torso, nรฃo aplique gel condutor ou pรกs condutoras destinadas ao uso em pacientes.

โ€“ Pressionar excessivamente os conectores durante a desfibrilaรงรฃo tambรฉm pode causar faรญscas e corrosรฃo.

โ€“ Nรฃo desfibrile o simulador sem a pele do torso.

Riscos mecรขnicos e elรฉtricos Nรฃo use o simulador SimJunior se:

โ€“ Os membros nรฃo estiverem conectados ao torso. โ€“ As peles estiverem rasgadas ou nรฃo estiverem presas

adequadamente. โ€“ Os cabos ou conectores internos e externos estiverem

danificados. โ€“ Houver um vazamento de fluido no simulador. โ€“ Houver ruรญdos fora do comum indicando vazamento de ar ou

dano mecรขnico. โ€“ Houver sinais de mau funcionamento do sistema elรฉtrico,

como falta de reaรงรฃo do simulador ou odor ou fumaรงa incomuns.

Advertรชncia:

โ€“ Evite riscos de esmagamento: nรฃo use o simulador sem as peles externas

Manutenรงรฃo e uso da bateria โ€“ Sempre use baterias aprovadas para alimentar o SimJunior, o Link

Box e o SimPad. โ€“ Verifique se as baterias estรฃo instaladas corretamente. A inserรงรฃo

ou conexรฃo incorreta das baterias pode causar curto-circuito.

Advertรชncias:

โ€“ Descarte as baterias de acordo com os regulamentos locais. โ€“ O carregador de bateria externo deve ser usado somente em

ambientes internos. โ€“ As baterias do simulador devem ser carregadas em temperaturas

variando de 0ยฐC - 40ยฐC (32ยฐF - 104ยฐF) โ€“ Nรฃo use de forma indevida, nรฃo desmonte nem tente consertar

a bateria. Nรฃo use as baterias se elas estiverem visivelmente danificadas, com defeito ou parecerem estar vazando.

โ€“ Tome extremo cuidado para evitar o contato com peรงas elรฉtricas, quentes ou que gerem fumaรงa. Em caso de vazamento, desconecte e remova a bateria quando for considerado seguro.

โ€“ A exposiรงรฃo a fluidos representa risco de explosรฃo.

โ€“ A cada 30 ciclos de carregamento, descarregue a bateria completamente antes de recarregรก-la. Para descarregar completamente a bateria, execute o simulador do paciente com alimentaรงรฃo da bateria atรฉ o desligamento automรกtico.

โ€“ Somente substitua por baterias da Laerdal para o SimJunior.

Transporte e armazenagem

โ€“ Nunca guarde baterias completamente carregadas por mais de um mรชs.

โ€“ A bateria pode ser transportada no simulador durante o transporte aรฉreo.

โ€“ Quando for transportar baterias sobressalentes, entre em contato com a companhia aรฉrea ou a empresa transportadora, para obter informaรงรตes sobre as normas mais recentes.

Advertรชncia:

โ€“ O simulador SimJunior e seus acessรณrios sรฃo pesados quando acondicionados na mala de transporte. Sempre segure o SimJunior com firmeza durante o transporte e armazenamento, para evitar ferimentos ou danos ao produto.

Page 117: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

115

Perna IO

Porta de preenchimento da perna IO

Simulador SimJunior

Conector de ECG para braรงo direito

Placa desfib. esterno

Braรงo para EV

Conector de ECG para perna direita

Cabo de alimentaรงรฃo

Conexรฃo de ar externo

Cabo do simulador (60 pinos)

Introduรงรฃo

Conector de ECG para braรงo esquerdo

Braรงo para pressรฃo arterial

Placa desfib. รกpice

Conector de ECG para perna esquerda

Page 118: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

116

Introduรงรฃo

Simulador SimJunior O SimJunior facilita o treinamento interativo das habilidades de salvamento de vida e reage ร  intervenรงรฃo clรญnica por meio de cenรกrios prรฉ-programados e/ou controlados pelo instrutor, para garantir a prรกtica efetiva de diagnรณstico e tratamento de pacientes.

Com respiraรงรฃo espontรขnea, controle das vias aรฉreas, voz, sons, ECG e outros recursos clรญnicos, o SimJunior รฉ um simulador pediรกtrico completamente funcional. O SimJunior possibilita a observaรงรฃo e o reconhecimento da maioria dos sinais vitais, fazendo com que o instrutor possa avaliar as habilidades do aluno com base em uma situaรงรฃo clรญnica realista.

Recursos do SimJunior

โ€“ Vias aรฉreas realistas para a simulaรงรฃo de manejo difรญcil das vias aรฉreas, intubaรงรฃo oral e nasal

โ€“ Respiraรงรฃo observรกvel

โ€“ Recursos cardรญacos, incluindo desfibrilaรงรฃo e cardioversรฃo

โ€“ Olhos com pupilas intercambiรกveis (normais, dilatadas ou contraรญdas)

โ€“ Convulsรตes para simular ataques

โ€“ Compressรตes torรกcicas

โ€“ Acesso vascular

โ€“ Sons cardรญacos, respiratรณrios e intestinais normais e anormais

โ€“ Controle de simulaรงรฃo automรกtica baseado em cenรกrios de paciente prรฉ-programados e validados

As simulaรงรตes podem ser executadas de forma autรดnoma usando cenรกrios no SimPad ou com o LLEAP (PC). A evoluรงรฃo do estado do paciente รฉ prรฉ-programada e sofre alteraรงรตes automaticamente, de acordo com as intervenรงรตes do participante.

Dimensรตes gerais

Comprimento/largura (somente o simulador): 120 cm x 42,5 cm (45 pol. x 9,84 pol.) Peso (somente o simulador): 11,36 kg (25 lbs)

Roupas para o SimJunior

O SimJunior รฉ fornecido com roupas criadas especialmente com aberturas com Velcro para facilitar a remoรงรฃo. As instruรงรตes de lavagem se encontram na etiqueta das roupas.

โ€“ Camisa

โ€“ Bermuda

โ€“ Cueca

Recursos clรญnicos gerais Recursos das vias aรฉreas

As vias aรฉreas sรฃo anatomicamente corretas em relaรงรฃo ร  traqueia. As vias aรฉreas podem ser manipuladas com:

โ€“ Inclinaรงรฃo da cabeรงa/elevaรงรฃo de queixo

โ€“ Manobra de elevaรงรฃo e traรงรฃo da mandรญbula com mandรญbula articulada

โ€“ Pressรฃo e manipulaรงรฃo cricoidea

โ€“ Sucรงรฃo (oral e nasofarรญngea)

O simulador pode ser ventilado pelos mรฉtodos normal e emergencial:

โ€“ Ventilaรงรฃo manual

โ€“ Intubaรงรฃo orotraqueal

โ€“ Intubaรงรฃo nasotraqueal

Antes de usar dispositivos para as vias aรฉreas, aplique o Lubrificante de vias aรฉreas da Laerdal.

Os seguintes equipamentos ou mรฉtodos sรฃo apropriados para uso nas vias aรฉreas do simulador:

โ€“ Vias aรฉreas com mรกscara larรญngea (tamanho 2,5)

โ€“ Intubaรงรฃo com tubo endotraqueal (tamanho ID 4,5 com manguito, 5,5 sem manguito)

O uso de um cateter maleรกvel รฉ recomendado. Certifique-se de que ele nรฃo se estenda alรฉm do tubo ET.

As seguintes condiรงรตes do simulador indicam posicionamento incorreto do tubo:

โ€“ Intubaรงรฃo no lobo direito โ€“ elevaรงรฃo torรกcica unilateral

โ€“ Distensรฃo estomacal

โ€“ Falta de sons torรกcicos (consulte a seรงรฃo Respiraรงรฃo)

Os recursos do simulador podem ser configurados para apresentar diversos cenรกrios das vias aรฉreas:

โ€“ Edema de lรญngua - nรญveis normal, mรฉdio, mรกximo

โ€“ Pulmรตes livres ou obstruรญdos

Recursos respiratรณrios

O SimJunior pode simular a respiraรงรฃo espontรขnea com elevaรงรฃo e depressรฃo torรกcicas visรญveis e frequรชncias respiratรณrias variรกveis. A respiraรงรฃo รฉ gerada por um compressor de ar instalado na coxa direita do simulador.

โ€“ Elevaรงรฃo e depressรฃo torรกcicas bilateral com respiraรงรฃo espontรขnea

โ€“ Elevaรงรฃo e depressรฃo torรกcicas unilateral com intubaรงรฃo do lobo direito durante ventilaรงรตes

โ€“ Sons pulmonares unilaterais e bilaterais

โ€“ Sons respiratรณrios normais e anormais

โ€“ Frequรชncia respiratรณria variรกvel (0-60 respiraรงรตes por minuto)

โ€“ Pontos de auscultaรงรฃo anteriores (4)

O pulmรฃo esquerdo e o pulmรฃo direito podem ser ocluรญdos de forma independente ou juntos, para criar uma obstruรงรฃo das vias aรฉreas parcial ou completa. O simulador SimJunior tambรฉm pode ser usado com ventilaรงรตes assistidas.

Nota: Os pulmรตes nรฃo devem ser usados com vรกlvulas PEEP.

Page 119: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

117

Introduรงรฃo

Recursos circulatรณrios

Cardรญaco:

โ€“ Biblioteca extensa de ECG, pulsos de 0-200

โ€“ Sons cardรญacos - ponto anterior (1)

โ€“ Monitoramento do ritmo do ECG (ECG com 4 conectores, 3 derivaรงรตes)

โ€“ Visor de ECG de 12 derivaรงรตes (somente usando o LLEAP)

โ€“ Estรญmulo

โ€“ Desfibrilaรงรฃo e cardioversรฃo usando desfibriladores ativos

Desfibrilaรงรฃo:

โ€“ O nรบmero de choques necessรกrios para conversรฃo automรกtica รฉ definido em cada caso de paciente simulado

Conectores de desfibrilaรงรฃo:

Conectores de ECG de 3 derivaรงรตes:

Pressรฃo e pulsos arteriais:

โ€“ PA medida manualmente por auscultaรงรฃo dos sons de Korotkoff

โ€“ Pulsos carotรญdeos bilaterais

โ€“ Os pulsos centrais podem ser definidos como Normal, Fraco, Ausente

โ€“ Os pulsos radial/braquial podem ser definidos como Normal, Fraco, Ausente

โ€“ Pulsos carotรญdeos, braquial e radial sincronizados com ECG

โ€“ Intensidade de pulso variรกvel com PA

โ€“ A palpaรงรฃo do pulso รฉ detectada e registrada

Recursos de RCP

โ€“ Em conformidade com as Diretrizes de 2010

โ€“ As compressรตes geram pulsos palpรกveis, forma de onda de pressรฃo arterial e artefatos de ECG

โ€“ Profundidade e resistรชncia da compressรฃo realistas

โ€“ Detecรงรฃo de profundidade e taxa de compressรตes

Recursos vasculares

Acesso EV:

ร‰ possรญvel fazer o acesso EV na mรฃo e no braรงo direitos. O braรงo para EV pode ser preparado para inserรงรฃo EV, infusรฃo e bolus em:

โ€“ Veias perifรฉricas do antebraรงo

โ€“ Fossa antecubital e dorso da mรฃo

Acesso intraรณsseo (IO):

O acesso para infusรฃo IO รฉ possรญvel:

โ€“ Tuberosidade tibial (direita)

โ€“ Malรฉolo medial

Nota: O SimJunior nรฃo inclui pontos para injeรงรฃo intramuscular (IM). Nรฃo tente administrar injeรงรตes IM.

Configuraรงรตes de som para o SimJunior O SimJunior fornece vรกrios pontos para auscultaรงรฃo e reconhecimento dos sons cardรญacos, pulmonares e intestinais. O SimJunior tambรฉm possibilita a configuraรงรฃo de sons vocais.

Para obter mais informaรงรตes sobre como configurar sons para o SimJunior, consulte as Instruรงรตes de uso do SimPad ou os arquivos de ajuda do LLEAP.

Page 120: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

118

Software de simulaรงรฃo

PC do instrutor

O PC do instrutor usa o software LLEAP para gerenciar as sessรตes de simulaรงรฃo. O LLEAP, bem como outros aplicativos รบteis relacionados ร  simulaรงรฃo, pode ser acessado pelo Laerdal Simulation Home.

Licenรงa de software O PC do instrutor รฉ fornecido pela Laerdal Medical com uma licenรงa prรฉ-ativada para o LLEAP instalado.

Alteraรงรตes ou atualizaรงรตes no hardware do computador (por exemplo, novo disco rรญgido ou placa-mรฃe) podem invalidar a licenรงa. Entre em contato com o suporte local da Laerdal para obter assistรชncia para reativar a licenรงa.

Laerdal Simulation HomeO Laerdal Simulation Home รฉ um aplicativo a partir do qual o LLEAP e outros programas da Laerdal relacionados ร  simulaรงรฃo de paciente podem ser encontrados e iniciados. Os arquivos de ajuda tambรฉm podem ser abertos neste local. O Laerdal Simulation Home estรก localizado na pasta Laerdal Medical, no menu Iniciar do Windows (Windows 7).

Os softwares usados em uma sessรฃo de simulaรงรฃo podem ser divididos nos seguintes aplicativos principais:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server ou Session Viewer

Alรฉm disso, o SimDesigner e outros aplicativos sรฃo usados para a criaรงรฃo e a preparaรงรฃo de uma simulaรงรฃo.

LLEAPO LLEAP (Laerdal Learning Application) รฉ o aplicativo do instrutor a partir do qual a sessรฃo de simulaรงรฃo รฉ executada, controlada e monitorada. O LLEAP pode ser operado em modo automรกtico ou manual. O modo automรกtico รฉ usado para cenรกrios prรฉ-programados e o modo manual garante ao instrutor total controle manual sobre a sessรฃo de simulaรงรฃo. Geralmente, a execuรงรฃo de simulaรงรตes no modo manual requer algum conhecimento mรฉdico para criar simulaรงรตes clinicamente plausรญveis.

Voice Conference Application (VCA)O software VCA รฉ necessรกrio para transmitir todos os sons vocais usados durante a simulaรงรฃo. Com ele, o instrutor pode se comunicar por meio do simulador durante a sessรฃo. O VCA tambรฉm pode ser usado para a comunicaรงรฃo com outros instrutores em uma rede e para criar canais separados, nos quais somente os membros podem falar e ouvir.

Patient MonitorO aplicativo Patient Monitor simula um monitor de paciente tรญpico de hospital. Ele รฉ o console do aluno e pode ser configurado e controlado pelo instrutor, bem como pelo aluno, por meio de menus de toque na tela.

Session Viewer e SimView ServerO Session Viewer e o SimView Server sรฃo aplicativos que gravam vรญdeo e capturas de tela do monitor de paciente, alรฉm de fornecer uma interface para o debriefing da sessรฃo. Apรณs o tรฉrmino de uma sessรฃo, os arquivos de registro gerados no LLEAP sรฃo transferidos e combinados com os arquivos de vรญdeo do Session Viewer ou SimView Server para o debriefing.

Geralmente, o Session Viewer รฉ executado localmente, no mesmo computador usado para o LLEAP, e o SimView Server รฉ executado em um servidor dedicado na rede local. Durante a primeira inicializaรงรฃo do LLEAP, vocรช รฉ solicitado a selecionar um sistema de debriefing disponรญvel no seu computador ou em uma rede local. Isso poderรก ser alterado mais tarde.

Outros aplicativosHรก outros programas que sรฃo usados em conjunto com as sessรตes de simulaรงรฃo, como, por exemplo, o License Manager, para lidar com as licenรงas de programa, e o Simulator Firmware & Network Wizard, para atualizar o firmware dos simuladores ou solucionar problemas de rede.

SimDesignerO SimDesigner รฉ um aplicativo para a configuraรงรฃo dos seus prรณprios cenรกrios prรฉ-programados. Ele tambรฉm pode ser usado para analisar e imprimir uma representaรงรฃo grรกfica de um cenรกrio.

O SimDesigner deve ser instalado para possibilitar a conversรฃo de arquivos do aplicativo do instrutor antigo em formatos de arquivo compatรญveis com o LLEAP.

Arquivos de ajuda

Para obter mais informaรงรตes sobre o software LLEAP e outros aplicativos, consulte os arquivos de ajuda:

1. No Windows, clique em <Iniciar> <Todos os programas>.

2. Selecione <Laerdal Simulation Home>.

3. Selecione <Ajuda>.

Downloads da webVisite www.laerdal.com/downloads para fazer o download do guia do usuรกrio e do software mais recente.

Page 121: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

119

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

Configuraรงรฃo do simulador

Preparaรงรฃo para simulaรงรตes Apรณs a preparaรงรฃo do simulador SimJunior e a configuraรงรฃo de todos os dispositivos interativos aplicรกveis (SimPad ou PC do instrutor e monitor do paciente), pode ser necessรกrio fazer preparaรงรตes finais antes do SimJunior estar pronto para executar simulaรงรตes.

As preparaรงรตes finais para simulaรงรฃo incluem as seguintes tarefas:

โ€ข Preparaรงรฃo da perna IO

โ€ข Administraรงรฃo de fluidos EV

โ€ข Drenagem do excesso de fluido EV

โ€ข Limpeza do braรงo para EV

โ€ข Conexรฃo das placas do adaptador de desfibrilaรงรฃo

โ€ข Conexรฃo do manguito de pressรฃo arterial

โ€ข Troca de pupilas

โ€ข Conexรฃo de um compressor externo

โ€ข Alteraรงรฃo das configuraรงรตes para o compressor interno

Preparaรงรฃo da perna IO A perna direita do simulador foi projetada para a prรกtica das habilidades de infusรฃo intraรณssea. A anatomia da perna direita inclui joelho, tรญbia, tuberosidade tibial e malรฉolo medial. A perna direita inclui um tubo EV e uma bolsa EV para uso como um reservatรณrio durante a infusรฃo.

Equipamentos adicionais necessรกrios:

โ€ข Bolsa EV e conjunto de administraรงรฃo

โ€ข Concentrado de sangue simulado

โ€ข Seringa de 35 cc e agulha intraรณssea de calibre 16

Para preencher a perna IO e preparรก-la para o uso:

1. Levante a perna verticalmente.

2. Abra a tampa no calcanhar.

3. Com uma seringa, preencha o osso com aproximadamente 240 a 250 mL de sangue simulado.

4. Encaixe o tubo conectado a uma bolsa de reservatรณrio EV. (Use o rolete para abrir ou fechar o cateter conforme necessรกrio, para aliviar o acรบmulo de pressรฃo.)

5. Feche o tubo que vai atรฉ a bolsa de reservatรณrio, para que o sangue simulado permaneรงa no osso para aspiraรงรฃo.

6. Quando a bolsa de reservatรณrio estiver cheia, interrompa a infusรฃo e substitua-a por uma bolsa vazia.

Antes de guardar o simulador:

โ€“ Remova o cateter EV e o reservatรณrio do pรฉ

โ€“ Deixe todo o fluido drenar

โ€“ Guarde a perna desacoplada para ela secar

Nota: Nรฃo use soluรงรฃo salina. Ela pode causar a deterioraรงรฃo da perna. Use รกgua destilada ou deionizada, para evitar o acรบmulo de minerais.

Administraรงรฃo de fluidos EV O braรงo direito para EV destina-se ร  prรกtica de administraรงรฃo de medicamentos EV, inserรงรฃo EV, infusรฃo e bolus nas veias perifรฉricas do antebraรงo, fossa antecubital e dorso da mรฃo.

Use uma agulha de calibre 20 a 22 para simulaรงรฃo EV. Para evitar a obstruรงรฃo do sistema EV, use somente รกgua destilada ou deionizada para simular medicamentos EV.

Page 122: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

120

Configuraรงรฃo do simulador

Drenagem de excesso de fluido EV O sistema de fluido EV รฉ um sistema aberto. Os fluidos EV sรฃo drenados conforme sรฃo administrados.

Antes de cada sessรฃo:

1. Conecte o tubo de alรญvio EV (no braรงo direito do simulador) a um recipiente de alรญvio (como uma bolsa EV).

2. Deixe que o excesso de fluido seja drenado para dentro do recipiente durante a simulaรงรฃo.

Limpeza do braรงo para EV Limpe o braรงos para EV apรณs cada sessรฃo ou dia de uso com isopropanol 60% ou etanol 70%.

Instalaรงรฃo das placas do adaptador de desfibrilaรงรฃo O torso do simulador inclui dois conectores para os cabos do desfibrilador. Antes de tentar realizar a desfibrilaรงรฃo, desparafuse e remova os conectores do desfibrilador.

Hรก duas placas do adaptador de desfibrilaรงรฃo no simulador. As placas do adaptador de desfibrilaรงรฃo devem ser encaixadas antes do uso de um desfibrilador ativo com pรกs de desfibrilaรงรฃo. Parafuse as placas do adaptador com firmeza.

Durante a desfibrilaรงรฃo Um desfibrilador convencional (nรฃo incluรญdo) pode ser usado no SimJunior. Durante a desfibrilaรงรฃo, o desfibrilador e o simulador podem apresentar risco de choque. Todas as precauรงรตes de seguranรงa padrรฃo devem ser adotadas durante o uso do desfibrilador em um simulador.

Cuidado: O simulador nรฃo deve entrar em contato com superfรญcies ou objetos condutores de eletricidade durante a desfibrilaรงรฃo.

Advertรชncias:

โ€“ A desfibrilaรงรฃo deve ser realizada somente com os conectores do desfibrilador.

โ€“ Nรฃo desfibrile o simulador sem a pele do torso.

Conexรฃo do manguito de pressรฃo arterial

O simulador รฉ fornecido com um manguito de pressรฃo arterial personalizado. Insira o tubo no conector de PA branco, na parte traseira do Link Box, antes de usar.

Nota: O alto-falante para a pressรฃo arterial do simulador fica localizado na fossa antecubital esquerda, destacada abaixo. Os pulsos radial e braquial ficam localizados nas รกreas retangulares.

Calibraรงรฃo do manguito de pressรฃo arterial no LLEAP

1. Selecione <Ferramentas> no menu

2. Selecione <Configuraรงรฃo do simulador> no menu Ferramentas

3. Selecione <Calibrar pressรฃo arterial> no submenu

4. Siga as instruรงรตes do assistente na tela para realizar a calibraรงรฃo

Calibraรงรฃo do manguito de pressรฃo arterial no SimPad

1. Selecione <Calibraรงรฃo> no menu.

2. Selecione <Calibrar PA> no menu suspenso.

3. Sigas as instruรงรตes do assistente na tela para realizar a calibraรงรฃo.

Page 123: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

121

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

Configuraรงรฃo do simulador

Troca de pupilas

O SimJunior รฉ fornecido com pupilas normais instaladas nos olhos. Um kit separado contendo peรงas plรกsticas de pupilas (contraรญdas e dilatadas) รฉ fornecido com o SimJunior.

Para trocar as pupilas:

1. Abra bem as pรกlpebras, com cuidado para nรฃo rasgar a pele do rosto do simulador.

2. Usando a ferramenta de ventosa de sucรงรฃo fornecida no kit ou com a ponta da unha, remova a pupila do olho cuidadosamente.

3. Substitua a pupila pela peรงa desejada, usando a ferramenta de ventosa de sucรงรฃo ou pressionando-a delicadamente.

Uso do compressor externo O compressor externo รฉ conectado ao tubo transparente que se encontra no conjunto de cabos que saem do lado direito do simulador. Quando um compressor externo for usado, o compressor interno pode ser desligado no SimPad ou no LLEAP.

Para obter mais informaรงรตes sobre os compressores externos ou painรฉis do regulador compatรญveis com o SimJunior, entre em contato com o seu representante local da Laerdal.

Como ligar ou desligar o compressor interno no SimPad

1. Inicie o <Modo manual>, selecione um tema e comece a sessรฃo.

2. Selecione <Diversos> no menu inferior.

3. Selecione <Compressor> no submenu.

4. Faรงa a alteraรงรฃo desejada na caixa de diรกlogo e clique em OK.

Como ligar ou desligar o compressor interno no LLEAP

1. Selecione <Ferramentas> no menu.

2. Selecione <Configuraรงรฃo do simulador> no menu Ferramentas.

3. Selecione <Compressor interno> no submenu.

4. Faรงa a alteraรงรฃo desejada na caixa de diรกlogo e clique em OK.

Page 124: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

122

Nota: Para obter informaรงรตes sobre peรงas sobressalentes, consulte a seรงรฃo: Peรงas sobressalentes e acessรณrios.

Antes do transporte ou da armazenagem

โ€“ Limpe o braรงo para EV com รกlcool isopropรญlico a 60% ou etanol a 70%. Abra a vรกlvula de drenagem na parte inferior do pรฉ direito do simulador.

Manutenรงรฃo

Manutenรงรฃo apรณs cada sessรฃo de simulaรงรฃo As seguintes medidas preventivas sรฃo necessรกrias para garantir a longevidade do simulador SimJunior.

โ€“ Desligue o SimPad, o Link Box e os PCs

โ€“ Se necessรกrio, carregue as baterias

โ€“ Limpe o sistema de braรงo EV e drene a perna IO (deixe o tampรฃo na parte inferior da perna IO aberto)

โ€“ Apรณs cada sessรฃo na qual o braรงo para EV foi usado, limpe-o com รกlcool isopropรญlico a 60% ou etanol a 70%

โ€“ Limpe a pele com um pano รบmido

โ€“ Remova as toalhas e panos molhados

โ€“ Remova o resรญduo de fita com um pano รบmido ou รกlcool

โ€“ Com base no uso do simulador, substitua os mรณdulos que estiverem gastos ou danificados

โ€“ Substitua os cabos ou conectores visivelmente danificados

โ€“ A manutenรงรฃo deve ser realizada por pessoal qualificado em intervalos regulares

Sempre faรงa a manutenรงรฃo:

โ€“ Se lรญquidos tiverem sido derramados dentro ou sobre o simulador

โ€“ Apรณs o uso em ambientes empoeirados

Page 125: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

123

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

Ace

ssรณr

ios

e pe

รงas

sobr

essa

lent

esEs

peci

ficaรง

รตes

In

trod

uรงรฃo

So

luรงรฃ

o de

pro

blem

as

Manutenรงรฃo

Abertura do torso

Abra o torso do simulador para realizar procedimentos como:

โ€“ Conexรฃo ou substituiรงรฃo de membros

โ€“ Substituiรงรฃo da bateria do simulador

โ€“ Substituiรงรฃo do balรฃo para elevaรงรฃo torรกcica e do balรฃo para pulmรฃo

โ€“ Substituiรงรฃo da pele do torso

โ€“ Para inspeรงรฃo geral

Advertรชncia: Abra o torso da esquerda para a direita e solte a pele com cuidado. Nรฃo puxe e pele do torso com forรงa, pois isso pode danificar os cabos do tรณrax.

1. Solte os ganchos da pele no lado esquerdo do torso e em cada ombro.

Substituiรงรฃo da bateria do simulador

1. Abra o torso do simulador.

2. Dobre a pele do torso para o lado direito.

3. Desconecte o cabo do desfibrilador.

4. O cabo do desfibrilador deve ser desconectado no lado direito do simulador, abaixo do tรณrax.

Nota: NรƒO desconecte os cabos e tubos que prendem a espuma do estรดmago ao simulador.

5. Recoloque a pele do torso seguindo as etapas 1 - 4 na ordem inversa.

2. Puxe a bateria para fora da tira da bateria.

3. Retire a conexรฃo de alimentaรงรฃo da bateria de dentro do simulador. Solte a conexรฃo de alimentaรงรฃo da bateria.

4. Retire a bateria do simulador.

5. Recoloque a bateria carregada ou ponha uma nova bateria do SimJunior aprovada pela Laerdal.

6. Conecte a bateria ao simulador.

7. Recoloque a pele do torso.

Page 126: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

124

Manutenรงรฃo

Carregamento da bateria do simulador

A bateria do simulador รฉ carregada automaticamente durante a operaรงรฃo. Se necessรกrio, a bateria do simulador pode ser carregada usando-se um adaptador de alimentaรงรฃo externa opcional.

1. Desligue o simulador pelo Link Box.

2. Remova a bateria do simulador.

3. Conecte um carregador de bateria externa aprovado (com um cabo de alimentaรงรฃo que cumpra as especificaรงรตes locais) ร  parte inferior da bateria do simulador. Conecte o cabo de alimentaรงรฃo do carregador a uma tomada elรฉtrica.

4. Quando a bateria terminar de ser carregada, recoloque-a no simulador.

Substituiรงรฃo do balรฃo para elevaรงรฃo torรกcica O balรฃo para elevaรงรฃo torรกcica fica localizado na extremidade inferior da placa torรกcica, centralizada sob os pulmรตes.

1. Abra a pele do torso para expor a placa torรกcica. Consulte Abertura do torso.

2. Desconecte o tubo transparente do balรฃo para pulmรฃo e remova o balรฃo. Para saber mais detalhes, consulte Substituiรงรฃo do balรฃo para pulmรฃo

3. Desconecte o tubo transparente do balรฃo para elevaรงรฃo torรกcica.

4. Descarte o balรฃo antigo.

5. Insira o novo balรฃo.

6. Reconecte o tubo ao novo balรฃo.

7. Feche o torso e recoloque a pele do torso.

Substituiรงรฃo do balรฃo para pulmรฃo Se ocorrer vazamento, o balรฃo para pulmรฃo (na cavidade torรกcica) deve ser substituรญdo.

1. Abra a pele do torso.

2. Desconecte o tubo transparente por baixo de cada lado do balรฃo para pulmรฃo. Consulte a ilustraรงรฃo da etapa 2 em Substituiรงรฃo do balรฃo para elevaรงรฃo torรกcica.

3. Desconecte a presilha do balรฃo da parte superior central.

4. Com cuidado, puxe a parte superior central do balรฃo da base de encaixe.

5. Inverta o processo para instalar um novo balรฃo para pulmรฃo.

Page 127: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

125

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

Ace

ssรณr

ios

e pe

รงas

sobr

essa

lent

esEs

peci

ficaรง

รตes

In

trod

uรงรฃo

So

luรงรฃ

o de

pro

blem

as

Substituiรงรฃo das peles do simulador As peles do simulador podem precisar ser substituรญdas, se forem rasgadas, perfuradas ou manchadas.

Pele do torso:

Para substituir a pele do torso do simulador, consulte Abertura do torso.

Pele do braรงo:

Para substituir a pele do braรงo do simulador:

1. Remova a pele antiga do braรงo do simulador, da parte superior atรฉ a parte inferior do braรงo e das mรฃos, ou *corte a pele.

Advertรชncia: *Nรฃo perfure ou corte o braรงo do mandril.

Para acoplar o novo braรงo:

Manutenรงรฃo

Substituiรงรฃo do braรงo direito para EV

1. Abra o torso, consulte Abertura do torso.

2. Remova o braรงo antigo desenroscando o parafuso que prende o braรงo no ombro do simulador.

3. Certifique-se de que o parafuso do ombro esteja solto o suficiente para possibilitar que o eixo do braรงo deslize facilmente para fora.

4. Descarte o braรงo antigo de acordo com as diretrizes especรญficas.

1. Certifique-se de que o parafuso do ombro esteja solto o suficiente para possibilitar que o eixo do braรงo deslize facilmente para a posiรงรฃo.

2. Instale o braรงo nos pontos de conexรฃo correspondentes no torso.

3. Com cuidado, empurre o eixo do braรงo para a base de encaixe do ombro, de modo que o eixo fique alinhado com a parte interna.

4. Aperte o parafuso do ombro com uma chave Allen.

Substituiรงรฃo da perna IO direita Para desacoplar a parte inferior da perna direita:

1. Verifique se os fluidos da perna foram drenados.

2. Remova a perna IO antiga soltando o parafuso que a prende ร  coxa.

3. Deslize a parte inferior da perna IO para fora da coxa.

4. Descarte a perna IO antiga de acordo com as diretrizes especรญficas.

Inverta o processo acima para acoplar a nova perna IO.

2. Descarte a pele antiga.

3. Lubrifique a parte interna da pele nova do braรงo com uma mistura de detergente lรญquido neutro e รกgua.

4. Lubrifique (ou lave) o mandril com uma mistura de sabonete lรญquido e รกgua.

5. Deslize a mรฃo do simulador para dentro da pele.

6. Coloque a pele sobre os dedos (como se fosse uma luva).

7. Puxe a pele sobre o mandril do braรงo.

Page 128: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

126

Soluรงรฃo de problemas

Configuraรงรฃo do sistema

Problema

โ€ข Perda de dados e falha completa do sistema (falha do sistema geral).

Soluรงรฃo possรญvel

โ€ข Se o sistema for encerrado ou todos os dados forem perdidos ou corrompidos, entre em contato com o seu centro de serviรงos local da Laerdal.

LLEAPโ€ข Consulte os Arquivos de ajuda de software > LLEAP > Guia de

soluรงรฃo de problemas. (A ajuda pode ser acessada a partir do Laerdal Simulation Home.)

Laerdal Patient Monitorโ€ข Consulte os Arquivos de ajuda de software > Laerdal Patient

Monitor > Guia de soluรงรฃo de problemas. (A ajuda pode ser acessada a partir do Laerdal Simulation Home.)

Debriefing e gravaรงรฃo de vรญdeoโ€ข Consulte a seรงรฃo de Soluรงรฃo de problemas, na Ajuda do SimView

(acessรญvel a partir de um link no canto inferior da pรกgina no SimView), ou o Guia de soluรงรฃo de problemas, na Ajuda do SessionViewer (acessรญvel no Laerdal Simulation Home).

Simulador

Problema

โ€ข Comportamento imprevisรญvel.

Soluรงรตes possรญveis

โ€ข Os problemas no funcionamento do simulador podem ser causados por cabos, conexรตes ou tubos soltos. Abra o torso e verifique se algum item parece ter se desconectado ou estar vazando. Consulte a seรงรฃo: Configuraรงรฃo do simulador - Abertura do torso.

โ€ข Em caso de vazamento de fluido, desligue o simulador e entre em contato com o Serviรงo Tรฉcnico da Laerdal.

Contaminaรงรฃo das vias aรฉreas

Problema

โ€ข As vias aรฉreas do simulador foram contaminadas na respiraรงรฃo boca a boca.

Soluรงรฃo possรญvel

โ€ข Limpe a parte externa do simulador com lenรงos umedecidos para simulador. Limpe a parte interna da cavidade bucal com lenรงos umedecidos para simulador. Troque o balรฃo para pulmรฃo; consulte a seรงรฃo: Manutenรงรฃo - Substituiรงรฃo do balรฃo para pulmรฃo.

Movimento torรกcico

Problema

โ€ข O simulador nรฃo apresenta elevaรงรฃo torรกcica.

Soluรงรตes possรญveis

โ€ข Verifique se o simulador estรก ligado.

โ€ข No SimPad ou no LLEAP, verifique se โ€“ awRR nรฃo estรก definido como zero

โ€“ A elevaรงรฃo torรกcica nรฃo estรก desligada

โ€“ ECG estรก definido para um ritmo de perfusรฃo.

โ€“ Verifique se nรฃo hรก complicaรงรตes definidas para as vias respiraรงรตes, como resistรชncia mรกxima do ar ou laringoespasmo.

โ€“ Verifique se o compressor integrado estรก ativado no LLEAP. Consulte a seรงรฃo: Como desligar o compressor interno.

โ€ข Verifique se alguma fonte externa de ar comprimido estรก desligada e se o tubo de ar estรก desconectado do simulador.

โ€ข O compressor interno pode estar superaquecido. Aguarde aproximadamente 20 minutos para ele resfriar.

โ€ข A elevaรงรฃo torรกcica estรก definida como bilateral (por exemplo, se o tubo ET foi introduzido fundo demais nos brรดnquios).

โ€ข O balรฃo para elevaรงรฃo torรกcica estรก com vazamento ou o tubo ligado ao balรฃo de elevaรงรฃo torรกcica estรก torcido ou desconectado. Se houver um vazamento, substitua o balรฃo para elevaรงรฃo torรกcica; consulte Manutenรงรฃo: Substituiรงรฃo do balรฃo para elevaรงรฃo torรกcica.

โ€ข Verifique se hรก vazamento nos tubos de ar ; verifique se todas as conexรตes estรฃo intactas. Substituiรงรฃo de parte do tubo, em caso de vazamento.

โ€ข Movimentos torรกcicos fracos, e o compressor interno funciona continuamente. O compressor interno pode estar gasto. Entre em contato com o Serviรงo tรฉcnico da Laerdal.

Pulmรตes

Problema

โ€ข Os pulmรตes nรฃo estรฃo funcionando corretamente

Soluรงรตes possรญveis

โ€ข Abra o torso e a placa torรกcica. Verifique se os pulmรตes estรฃo livres para expandir e nรฃo estรฃo restringidos por cabos.

โ€ข Verifique se o balรฃo do pulmรฃo estรก conectado corretamente e os tubos nรฃo estรฃo torcidos.

โ€ข Verifique se o balรฃo do pulmรฃo estรก em uma posiรงรฃo horizontal e inserido corretamente.

Page 129: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

127

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s

Intr

oduรง

รฃo

Solu

รงรฃo

de p

robl

emas

Soluรงรฃo de problemas

โ€ข Verifique se hรก defeitos ou rasgos no balรฃo do pulmรฃo.

โ€ข Verifique se nรฃo hรก obstruรงรตes dentro das vias aรฉreas do simulador que possam impedir o fluxo de ar.

โ€ข Se nรฃo houver alteraรงรฃo quando a complacรชncia pulmonar for ajustada, entre em contato com o Serviรงo Tรฉcnico da Laerdal.

โ€ข Se nรฃo houver alteraรงรฃo na resistรชncia pulmonar, entre em contato com o Serviรงo Tรฉcnico da Laerdal.

Ruรญdo mecรขnico durante a auscultaรงรฃoNo LLEAP, clique em <Foco de auscultaรงรฃo>.

Pulsos (radial e braquial)

Problema

โ€ข Nรฃo รฉ possรญvel sentir os pulsos

Soluรงรตes possรญveis

โ€ข A pele pode estar apertada demais sobre as unidades de pulso. Ajeite a pele e reinicie.

โ€ข Certifique-se de que a pressรฃo arterial esteja definida como pelo menos 60 sistรณlica.

โ€ข Verifique se o compressor estรก ligado.

Nota: Se o pulso radial for definido abaixo de 60, os pulsos perifรฉricos poderรฃo desaparecer.

Desligamento do simulador

Problema

โ€ข O simulador nรฃo responde.

Soluรงรฃo

1. Desligue o Link Box.

2. Desligue o SimPad ou, se o LLEAP estiver sendo usado, desligue o PC do instrutor.

3. Reinicie tudo.

Se o simulador continuar nรฃo respondendo, entre em contato com seu representante da Laerdal.

Page 130: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

128

Notas

Page 131: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

129

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

A

cess

รณrio

s e

peรงa

s so

bres

sale

ntes

Espe

cific

aรงรตe

s In

trod

uรงรฃo

So

luรงรฃ

o de

pro

blem

as

Especificaรงรตes

Dimensรตes gerais Comprimento/largura (somente o simulador): 120 cm x 42,5 cm (45 pol. x 9,84 pol.) Peso (somente o simulador): 11,36 kg (25 lbs)

Alimentaรงรฃo do simulador Alimentaรงรฃo externa: Tensรฃo de entrada 9 VCC, 1.5 A Bateria interna: 7,4 V, 4,4 Ah, รญon-lรญtio

Use somente a fonte de alimentaรงรฃo externa e as baterias aprovadas do SimJunior

Pressรฃo de ar Reservatรณrio de ar interno: Mรกx. de 6 psi Conexรฃo de ar externa: Mรกx. de 16 psi

Limites de temperatura Temperaturas em funcionamento: +4ยบC a 40ยบC (39ยบF a 104ยบF) Temperaturas de armazenamento: -15ยบC a 50ยบC (5ยบF a 122ยบF)

Ambiente - somente o simulador Umidade relativa: 20% -90% (sem condensaรงรฃo) NรƒO use em ambientes externos na presenรงa de umidade. Nรฃo testados com spray de sal.

Comunicaรงรฃo por RF Faixa de operaรงรฃo: 10 m (30 pรฉs) mรกx.

Lista de materiais do simulador Roupas: Algodรฃo, nรกilon Peles e vias aรฉreas: PVC Peรงas plรกsticas externas: PVC, ABS Peรงas plรกsticas internas: Silicone, TPU, PVC, nitrilo ABS, POM, nรกilon + GF Epรณxi-poliuretano Componentes metรกlicos: Alumรญnio, latรฃo, aรงo

Requisitos mรญnimos do computador

โ€ข Intel i-core geraรงรฃo 3 ou mais recente

โ€ข Pontuaรงรฃo acima de 3000 PassMark - CPU Mark

โ€ข 4 GB de RAM

โ€ข 120 GB de espaรงo em disco rรญgido

โ€ข 1366 x 768 ou mais

โ€ข Fones de ouvido com microfone

โ€ข Portas USB โ€“ 2

Requisitos mรญnimos de software

โ€ข Windows 7 ou Windows 8

โ€ข 100% de DPI

Fluidos de limpeza Para limpar o simulador, use um dos seguintes produtos:

โ€“ รlcool isopropรญlico a 60%

โ€“ Etanol a 70%

โ€“ Soluรงรฃo neutra de sabรฃo lรญquido e รกgua

Fluidos EV Use somente รกgua destilada ou deionizada para simular os fluidos EV e IO.

Page 132: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

130

Notas

Page 133: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

131

Soft

war

e de

sim

ulaรง

รฃo

Con

figur

aรงรฃo

do

sim

ulad

or

Man

uten

รงรฃo

Ace

ssรณr

ios

e pe

รงas

sobr

essa

lent

esEs

peci

ficaรง

รตes

In

trod

uรงรฃo

So

luรงรฃ

o de

pro

blem

as

Acessรณrios e peรงas sobressalentes

Acessรณrios e peรงas sobressalentesPara obter a versรฃo mais recente de Peรงas sobressalentes e acessรณrios, visite www.laerdal.com.

Page 134: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

132

Notas

Page 135: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

133

Onderhoud 144

โ€“ Onderhoud na elke simulatiesessie 144 โ€“ Openen van de torso 145 โ€“ Vervangen van de accu van de simulator 145 โ€“ Opladen van de accu van de simulator 146 โ€“ Vervangen van het ballonnetje voor

de borstkasbeweging 146 โ€“ Vervangen van de longen 146 โ€“ Vervangen van de huid van de simulator 147 โ€“ Vervangen van de rechter IV-arm 147 โ€“ Vervangen van het rechterbeen (IO-been) 147

Probleemoplossing 148

Inleiding 134

โ€“ Informatie over regelgeving 134 โ€“ Onderhoud van de simulator 135โ€“ Overzichtsfoto van de SimJunior 137 โ€“ Eigenschappen van de SimJunior 138

Simulatorinstallatie 141

โ€“ Simulaties voorbereiden 141 โ€“ Voorbereiding van het IO-been 141 โ€“ Toedienen van IV-vloeistoffen 141 โ€“ Draineren van overtollige IV-vloeistof 142 โ€“ Reinigen van de IV-arm 142 โ€“ Installeren van de defibrillatieplaten 142 โ€“ Aansluiten van de bloeddrukmanchet 142 โ€“ IJken van de bloeddrukmanchet in LLEAP 142โ€“ IJken van de bloeddrukmanchet in SimPad 142โ€“ Vervangen van de pupillen 143 โ€“ Gebruik van een externe compressor 143

Specificaties 151

Simulatiesoftware 140

โ€“ Pc van instructeur 140 โ€“ Softwarelicentie 140 โ€“ Laerdal Simulation Home 140โ€“ LLEAP 140โ€“ Voice Conference Application 140โ€“ Patient Monitor 140โ€“ Session Viewer en SimView Server 140โ€“ Overige applicaties 140โ€“ SimDesigner 140โ€“ Helpbestanden 140โ€“ Webdownloads 140

Reserveonderdelen en accessoires 153

Inhoudsopgave NL

Page 136: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

134

Li-ion

Inleiding

Leer de SimJuniorโ„ข Simulator kennen De SimJunior is een realistische, levensgrote oefenpop die door Laerdal is ontworpen, in samenwerking met de American Academy of Pediatrics. De SimJunior kan worden gebruikt voor individuele of groepen zorgverleners vanuit meerdere medische disciplines.

De SimJunior Simulator wordt geheel gemonteerd geleverd. Het is dus niet nodig om de simulator in elkaar te zetten.

Ga voor informatie over het gereedmaken van de SimJunior voor simulatie naar de paragraaf โ€œSimulatorinstallatieโ€.

SimJunior Help Gebruiksaanwijzing

Stap-voor-stap instructies en illustraties voor het gebruik van de SimJunior Simulator.

Originele gebruikershandleidingen van de fabrikant

Alle afzonderlijke gebruikershandleidingen en labels van oorspronkelijke fabrikanten moeten worden opgevolgd. De gebruiksaanwijzing voor de SimJunior is niet bedoeld als vervanging van en treedt niet in de plaats van die van de oorspronkelijke fabrikant.

Snelle installatiegids voor de SimJunior

Stap-voor-stap handleiding voor installatie van het SimJunior simulatiesysteem.

Gebruiksaanwijzing voor de SimPad

In de gebruiksaanwijzing voor de SimPad staan instructies voor het gebruik van de Link Box en de SimPad met de SimJunior.

LLEAP Help (Laerdal Learning Application: Laerdal opleidingsapplicatie)

De LLEAP Help is toegankelijk vanuit Laerdal Simulation Home, zie Laerdal Simulation Home.

De helponderwerpen zijn:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Applicatie Trend Editor

Technische ondersteuning

Neem voor technische ondersteuning contact op met de lokale technische dienst van Laerdal.

Webdownloads

Ga naar www.laerdal.com/downloads om de nieuwste gebruiksaanwijzingen te downloaden, en nieuwere versies van de simulatiesoftware.

Inhoud van SimCenter SimCenter biedt toegang tot gevalideerde inhoud van simulatiedeskundigen van over de hele wereld, zodat u gebruik kunt maken van hun ervaringen en het optimale uit iedere leersituatie kunt halen. U treft een breed scala aan scenario's aan die speciaal voor de SimJunior zijn ontwikkeld. Ga naar www.mysimcenter.com om te ontdekken hoe u uw leerervaringen kunt optimaliseren.

Informatie over regelgeving

Federal Communications Commission Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

Opgelet Wijzigingen of aanpassingen die niet expliciet zijn goedgekeurd door de verantwoordelijke voor naleving kunnen de bevoegdheid van de gebruiker tot bediening van dit apparaat ongeldig maken.

Li-ion batterijen moeten worden gerecycleerd.

Laerdal Medical AS verklaart hierbij dat dit product, indien het een CE-markering heeft, voldoet aan de essentiรซle vereisten en andere relevante bepalingen in Richtlijn 1999/5/EG.

Afvoeren in overeenstemming met lokale eisen en regelgeving.

Page 137: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

135

Inleiding

Onderhoud van de simulator Volg de instructies hieronder voor optimale prestaties en een lange levensduur van de simulator en de onderdelen ervan.

Algemeen onderhoud

Was voor gebruik uw handen om de huid van de simulator schoon te houden en plaats de simulator op een schoon oppervlak. Laerdal adviseert:

โ€“ Gebruik tijdens de simulatiescenario's handschoenen. Gebruik geen gekleurde plastic handschoenen. Deze kunnen verkleuring van de huid van de simulator veroorzaken.

โ€“ Gebruik geen viltstiften, inktpennen, aceton, jodium of andere producten die verkleuringen veroorzaken in de nabijheid van de simulator. Leg de simulator niet op krantenpapier of gekleurd papier. Vlekken kunnen wellicht niet meer verwijderd worden.

โ€“ Reinig de huid van de simulator met milde zeep en water.

Pas de hierna genoemde technieken niet op de simulator toe, omdat de luchtwegen niet naar behoren kunnen worden gedesinfecteerd:

โ€“ Mond-op-mond-/mond-op-maskerbeademing

โ€“ Inbrengen van gesimuleerd braaksel of vloeistoffen om te aspireren.

โ€“ Als bij een trainingssessie vloeistoffen in de IV-arm ingespoten zijn, leeg de arm dan onmiddellijk erna.

โ€“ Gebruik alleen Laerdal Airway Lubricant en breng dit met mate aan

โ€“ Spoel de onderdelen af, reinig en droog ze

โ€“ Klap de huid van de torso om en poeder de binnenzijde van de torsohuid om de wrijving te verminderen. Mors geen poeder in de borstholte van de simulator.

Omgeving Wacht onder koude omstandigheden totdat de simulator op kamertemperatuur is gekomen voordat u deze start.

Vermijden van oververhitting en beperking van slijtage:

โ€“ Laat de simulator, wanneer u deze bij temperaturen boven de 40 ยฐC gebruikt, tussen twee trainingssessies in altijd eerst afkoelen.

โ€“ Wordt de simulator in een bed gebruikt, bedek hem dan niet met zwaar beddengoed dat verhindert dat de simulator de warmte kan afgeven.

Algemeen gebruik van de simulator Neem de volgende voorzorgsmaatregelen om persoonlijk letsel of schade aan het product te voorkomen:

โ€“ Breng vloeistoffen in de simulator uitsluitend in zoals in dit document is aangegeven.

โ€“ Bevochtig de orale en nasale luchtwegen met het meegeleverde glijmiddel voordat u een instrument, een slang of luchtwegapparatuur inbrengt. Smeer ook instrumenten en slangen voor gebruik in met glijmiddel.

โ€“ Gebruik geen bevochtigde lucht in het systeem tijdens de ventilatie

โ€“ Gebruik de simulator niet als de interne leidingen of bekabeling losgekoppeld zijn

โ€“ Gebruik de SimJunior simulator in geen geval onder natte omstandigheden buitenshuis. Hierdoor kan het gevaar van een elektrische schok ontstaan of kan de simulator beschadigd raken.

โ€“ Het gebruik van een defibrillator bij temperaturen boven de 35 ยฐC kan oververhitting veroorzaken

Waarschuwing: Gebruik geen geautomatiseerde compressiemachine op de simulator.

Opgelet latex: Dit product bevat natuurlijk rubberlatex; dit kan bij aanraking bij mensen allergische reacties oproepen.

Defibrillatie-gevaren Bij de SimJunior is defibrillatie mogelijk.

Op de SimJunior kan een conventionele defibrillator worden gebruikt. Tijdens defibrillatie kunnen de defibrillator en de simulator een schok veroorzaken. Alle standaard veiligheidsmaatregelen moeten worden genomen bij gebruik van een defibrillator op de simulator.

โ€ข Lees en volg alle veiligheids- en gebruiksinstructies die met uw defibrillator en bijbehorende apparatuur zijn meegeleverd.

โ€ข Volg het defibrillatieprotocol en vermijd tijdens het defibrilleren contact tussen de externe paddels en de locaties met de elektrodes. Er kan een schok van maximaal 300 joule worden toegediend.

โ€ข Het niet volgen van de veiligheidsmaatregelen kan leiden tot letsel of overlijden.

Raadpleeg voor meer informatie de oorspronkelijke gebruikershandleiding van de defibrillator.

Waarschuwingen:

โ€“ Gebruik bij het defibrilleren de defibrillatoraansluitingen of de defibrillatieplaat die is bevestigd op de borstkas van de oefenpop. Gebruik niet de ECG-aansluitingen die alleen bestemd zijn voor ECG-monitoring. Defibrillatie op de ECG-aansluitingen zal de interne elektronica van de simulator beschadigen en kan persoonlijk letsel veroorzaken.

โ€“ Defibrilleer de simulator niet als deze UIT staat of als deze niet normaal functioneert.

Disclaimer Gebruik van het SimJunior patiรซntsimulatiesysteem voor het trainen van personeel moet plaatsvinden onder toezicht van goed getraind technisch of medisch personeel met inzicht in onderwijsgrondbeginselen en in erkende, medische protocollen. Net als bij alle simulators en andere dergelijke trainingshulpmiddelen kunnen er benaderingen, verschillen en onnauwkeurigheden zijn in anatomische kenmerken en in de fysiologische modellering. Daarom biedt Laerdal geen garantie dat alle functies volledig nauwkeurig zijn.

Wereldwijde garantie Raadpleeg het garantieboekje van de wereldwijde garantie of ga naar www.laerdal.com.

Land van oorsprong - de SimJunior wordt gefabriceerd in de VS.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 138: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

136

Inleiding

Gebruik niet meer dan 3 defibrillatieschokken per 45 seconden gevolgd door 1 minuut hartmassage om oververhitting tijdens defibrillatie te voorkomen. Houd na 30 minuten tenminste 15 minuten op met het toedienen van schokken voordat u een nieuwe reeks begint. Herhaal dit gedurende niet langer dan een periode van 4 uur. Geef ook niet meer dan 2 x 300 defibrillatorontladingen per minuut.

Waarschuwingen:

โ€“ De simulator mag tijdens defibrillatie niet in contact komen met elektrisch geleidende oppervlakken of voorwerpen.

โ€“ Vermijd het gebruik in alle ontvlambare omgevingen. Hoge doses zuivere zuurstof bijvoorbeeld moeten tijdens defibrillatie worden vermeden. Zorg voor een goede ventilatie wanneer in de nabijheid van de simulator zuurstof in hoge concentraties wordt gebruikt.

โ€“ Houd de torso van de simulator altijd droog.

โ€“ Laat de simulator acclimatiseren voordat u met defibrillatie begint. Plotselinge temperatuurveranderingen kunnen leiden tot condensvorming op elektronische componenten, wat een potentieel gevaar voor een schok kan inhouden.

โ€“ Gebruik geen geleidende gel of geleidende defibrillatie-elektroden (voor gebruik bij patiรซnten), om beschadiging aan de huid van de torso te voorkomen.

โ€“ Ook te hard drukken op de defibrillatieconnectoren tijdens defibrillatie kan boogvorming of de vorming van putjes veroorzaken.

โ€“ Defibrilleer de simulator niet als de huid van de torso niet op zijn plaats zit.

Mechanische of elektrische gevaren Gebruik de SimJunior simulator niet wanneer:

โ€“ de ledematen niet aan de torso zijn bevestigd โ€“ de huid gescheurd of niet goed bevestigd is โ€“ interne of externe kabels, slangen of aansluitingen beschadigd zijn โ€“ er een vloeistoflek in of op de simulator is โ€“ er ongebruikelijke geluiden zijn die duiden op een luchtlek of

mechanische schade โ€“ er tekenen zijn van een elektrische storing, zoals een

niet-reagerende simulator of een ongebruikelijke geur, of rook

Waarschuwing:

โ€“ Vermijd knelgevaar - Gebruik de simulator niet zonder externe huiden

Accugebruik en -onderhoud โ€“ Gebruik altijd accu's die zijn goedgekeurd als voedingsbron voor

de SimJunior, Link Box en SimPad. โ€“ Zorg dat de accuโ€™s goed zijn geรฏnstalleerd. Het onjuist plaatsen en

aansluiten van accuโ€™s kan kortsluiting veroorzaken.

Waarschuwingen:

โ€“ Verwijder batterijen/accu's met inachtneming van de plaatselijke regelgeving.

โ€“ De externe acculader dient uitsluitend voor gebruik binnenshuis. โ€“ De accu van de simulator mag alleen worden opgeladen bij

temperaturen tussen 0 ยฐC - 40 ยฐC. โ€“ Behandel de accu niet verkeerd, haal hem niet uit elkaar en

probeer niet hem te repareren. Gebruik de accuโ€™s niet als ze zichtbaar beschadigd zijn, niet goed werken of lijken te lekken.

โ€“ Wees uiterst voorzichtig en vermijd direct contact met elektrische, hete of rokende onderdelen. Als een accu lekt, moet deze worden ontkoppeld en verwijderd als men het veilig acht om dit te doen.

โ€“ Blootstelling aan vloeistoffen betekent een explosiegevaar.

โ€“ Laat bij elke 30e oplaadcyclus de accu eerst geheel leeglopen. Laat, om de accu leeg te laten lopen, de simulator op accustroom draaien totdat hij automatisch uitgaat.

โ€“ Alleen vervangen door een Laerdal SimJunior accu.

Opslag en vervoer

โ€“ Bewaar volledig geladen accuโ€™s nooit langer dan een maand.

โ€“ De accu van de simulator kan tijdens een vliegreis in de simulator worden vervoerd.

โ€“ Neem bij het vervoeren van reserve-accuโ€™s contact op met de luchtvaartmaatschappij of het vrachtbedrijf voor de meest recente vrachtregelingen.

Waarschuwing:

โ€“ De SimJunior Simulator en accessoires zijn zwaar als ze allemaal in dezelfde draagtas worden vervoerd. Zorg altijd dat de SimJunior goed is vastgezet tijdens vervoer en opslag om persoonlijk letsel of beschadiging aan het product te voorkomen.

Page 139: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

137

IO-been

Vulpoort IO-been

SimJunior simulator

ECG-aansluiting rechterarm

Defib. plaat sternum

IV-arm

ECG-aansluiting rechterbeen

Stroomkabel

Aansluiting externe lucht

Simulatorkabel (60-pins)

Inleiding

ECG-aansluiting linkerarm

Bloeddrukarm

Defib. plaat apex

ECG-aansluiting linkerbeen

Page 140: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

138

Inleiding

SimJunior simulator De SimJunior vergemakkelijkt interactieve training in levensreddende vaardigheden en reageert op klinische interventie onder toezicht van de instructeur, en/of via voorgeprogrammeerde scenarioโ€™s voor effectieve diagnose en behandeling van een patiรซnt.

Bij spontane ademhaling, luchtwegregeling, spraak, geluiden, ECG en andere klinische kenmerken is de SimJunior een geheel functionele (kind)simulator. De SimJunior maakt observatie en herkenning van de meeste vitale functies mogelijk, zodat de instructeur de vaardigheden van de student kan vaststellen op basis van een realistische klinische situatie.

Eigenschappen van de SimJunior

โ€“ Realistische luchtweg voor simulatie van problematische luchtwegbehandeling, orale en nasale intubatie

โ€“ Waarneembare ademhaling

โ€“ Harteigenschappen, waaronder defibrillatie en cardioversie

โ€“ Ogen met verwisselbare pupillen (normaal, verwijd of vernauwd)

โ€“ Convulsies om epileptische aanvallen te simuleren

โ€“ Borstcompressies

โ€“ Vasculaire toegang

โ€“ Normale en abnormale hart-, ademhalings- en darmgeluiden

โ€“ Automatische simulatieregeling gebaseerd op voorgeprogrammeerde en gevalideerde scenarioโ€™s

Simulaties kunnen autonoom lopen bij het gebruik van scenario's op de SimPad of met LLEAP (pc). Het verloop in de toestand van de patiรซnt is voorgeprogrammeerd en reageert automatisch volgens de interventies van de deelnemer.

Totaalafmetingen

Lengte/breedte (alleen simulator): 120 cm x 42,5 cmGewicht (alleen simulator): 11,36 kg

Kleding SimJunior

De SimJunior wordt geleverd met op maat gemaakte kleding met klittenbandsluitingen zodat deze eenvoudig verwijderd kan worden. Wasinstructies zijn aangegeven op het etiket in de kleding.

โ€“ Hemd

โ€“ Korte broek

โ€“ Boxershort

Algemene klinische eigenschappen Luchtwegeigenschappen

De luchtweg is anatomisch juist ten opzichte van de trachea. De luchtweg kan worden gemanipuleerd door:

โ€“ Hoofd kantelen/kinlift

โ€“ Jaw-thrust met beweegbare kaak

โ€“ Cricoรฏddruk en manipulatie

โ€“ Suctie (oraal en nasofaryngeaal).

De simulator kan worden beademd via normale en invasieve methoden:

โ€“ Masker-ballon-beademing

โ€“ Orotracheale intubatie

โ€“ Nasotracheale intubatie

Te gebruiken luchtweginstrumenten moeten van te voren worden gesmeerd met Laerdal Airway Lubricant.

De volgende apparatuur of methoden zijn geschikt voor het stabiel houden van de luchtweg van de simulator:

โ€“ Larynxmasker (maat 2,5)

โ€“ Endotracheale intubatie (maat-ID 4,5 met cuff, 5,5 zonder cuff)

Het gebruik van een flexibel stilet wordt aanbevolen. Zorg dat dit niet voorbij de ET-tube uitsteekt.

De volgende toestand van de simulator geeft aan dat de plaatsing van de slang onjuist is:

โ€“ Intubatie rechterhoofdbronchus โ€“ borstkas gaat eenzijdig omhoog

โ€“ Maagdistentie

โ€“ Ontbreken van borstkasgeluiden (zie paragraaf Ademhaling)

De eigenschappen van de simulator kunnen worden geconfigureerd voor verschillende luchtwegscenarioโ€™s:

โ€“ Tongoedeem - normaal, medium, maximum niveau

โ€“ Longen open of gesloten

Ademhalingseigenschappen

De SimJunior kan spontane ademhaling simuleren, met zichtbaar op en neer gaan van de borstkas en met variabele ademhalingssnelheden. Een luchtcompressor in de rechterdij van de simulator zorgt voor de ademhalingsbeweging.

โ€“ De borstkas gaat aan symmetrisch op bij spontane ademhaling

โ€“ Bij hoofdbronchusintubatie rechts gaat de borst asymmetrisch op

โ€“ Eenzijdige en bilaterale longgeluiden

โ€“ Normale en abnormale ademgeluiden

โ€“ Variabele ademhalingssnelheid (0-60 ademhalingen per minuut)

โ€“ Anterieure auscultatieplaatsen (4)

De linker- en rechterlong kunnen onafhankelijk van elkaar of tegelijkertijd worden gesloten om gedeeltelijke of gehele luchtwegafsluiting na te bootsen. De SimJunior simulator kan ook worden gebruikt met ondersteunde beademing.

Opmerking: De longen zijn niet bestemd voor gebruik met PEEP-kleppen.

Page 141: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

139

Inleiding

Circulatie-eigenschappen

Cardiaal: โ€“ Uitgebreide ECG-bibliotheek, hartslag tussen 0-200โ€“ Hartgeluiden - voorzijde (1) โ€“ ECG ritmebewaking (4 aansluitingen, 3-lead ECG) โ€“ 12-lead ECG-display (alleen bij gebruik van LLEAP) โ€“ Pacing โ€“ Defibrillatie en cardioversie met echte defibrillatoren

Defibrillatie:

โ€“ Het aantal schokken dat is vereist voor automatische conversie wordt ingesteld bij elke casus

Defibrillatie-connectoren:

Aansluiting voor 3-lead ECG:

Bloeddruk en polsslag: โ€“ De bloeddruk wordt handmatig gemeten via auscultatie van

korotkovtonen โ€“ Bilaterale carotispols โ€“ De centrale polsslagen kunnen worden ingesteld op normaal,

zwak en afwezig โ€“ De radiale/brachiale polsslagen kunnen worden ingesteld op

normaal, zwak en afwezig โ€“ De carotis-, brachiale en radiale polsslagen zijn gesynchroniseerd

met het ECG โ€“ Sterkte van hartslag is gekoppeld aan de bloeddrukโ€“ Palpaties van de pols worden gedetecteerd en vastgelegd

Reanimatie-eigenschappen

โ€“ Conform richtlijnen 2010

โ€“ Compressies genereren voelbare polsslagen, een bloeddrukcurve en ECG-artefacten

โ€“ Realistische compressiediepte en -weerstand

โ€“ Detectie van diepte en snelheid van de compressies

Vasculaire eigenschappen

IV-toegang:

IV-toegang is mogelijk in de rechterarm en -hand. De IV-arm kan worden ingesteld op IV-inbrenging, infusie en bolus in:

โ€“ Perifere aderen van de onderarm

โ€“ Antecubitale fossa en dorsum van de hand

Intraossale (IO) toegang:

Toegang voor IO-infusie is mogelijk:

โ€“ Tibiale tuberositeit (rechts)

โ€“ Malleolus medialis

Opmerking: De SimJunior heeft geen intramusculaire (IM) injectieplaatsen. Probeer niet om IM injecties te geven.

Geluidsinstellingen voor de SimJunior De SimJunior ondersteunt meerdere plaatsen voor auscultatie en het herkennen van hart-, long, en darmgeluiden. De SimJunior stelt u ook in staat om stemgeluiden in te stellen.

Zie de gebruiksaanwijzing voor de SimPad of de LLEAP Help voor meer informatie over het instellen van geluid voor SimJunior.

Page 142: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

140

Simulatiesoftware

Pc van instructeur

Op de pc van de instructeur wordt LLEAP-software gebruikt om de simulatiesessies te beheren. LLEAP is net als andere nuttige simulatiegerelateerde applicaties toegankelijk via Laerdal Simulation Home.

Softwarelicentie De pc van de instructeur wordt door Laerdal Medical verzonden met een geactiveerde licentie voor LLEAP erop geรฏnstalleerd.

Veranderingen of updates van de computerhardware (bijv. nieuwe harde schijf of nieuw moederbord) kunnen de licentie ongeldig maken. Neem contact op met uw lokale Laerdal ondersteuning voor hulp bij het opnieuw activeren van de licentie.

Laerdal Simulation HomeLaerdal Simulation Home is een applicatie van waaruit LLEAP en andere Laerdal-programma's voor patiรซntsimulatie kunnen worden gevonden en gestart. Ook de helpbestanden kunnen van hieruit worden geopend. Laerdal Simulation Home bevindt zich in de map Laerdal Medical in het Windows startmenu (Windows 7).

De software die in een simulatiesessie wordt gebruikt, bestaat uit de volgende hoofdtoepassingen:

โ€“ LLEAP (Laerdal Learning Application: Laerdal opleidingsapplicatie)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server of Session Viewer (sessieweergave)

Daarnaast worden SimDesigner en andere applicaties gebruikt om een simulatie te ontwikkelen en voor te bereiden.

LLEAPDe Laerdal Learning Application (LLEAP) is de applicatie voor de instructeur van waaruit de simulatiesessie wordt uitgevoerd, gestuurd en bewaakt. LLEAP kan zowel in de automatische modus als in de handmatige modus worden uitgevoerd. De automatische modus wordt gebruikt voor vooraf geprogrammeerde scenario's, terwijl in de handmatige modus de instructeur in staat is de simulatiesessie volledig handmatig te sturen. Voor het uitvoeren van simulaties in de handmatige modus is medische expertise vereist, wil de simulatie medisch met de werkelijkheid overeenstemmen.

Voice Conference Application (VCA)De VCA-software dient om tijdens de simulatie alle gebruikte stemgeluiden te verzenden. Hiermee kan de instructeur tijdens de sessie via de simulator communiceren. Ook kan VCA worden gebruikt om met andere instructeurs in een netwerk te communiceren, en om gescheiden kanalen te creรซren waarop alleen leden kunnen praten en luisteren.

Patient MonitorDe applicatie Patient Monitor bootst een algemeen voor patiรซnten gebruikte ziekenhuismonitor na Dit is de console van de student; hij kan door de instructeur worden geconfigureerd en gestuurd, alsook door de student via de menu's op het touchscreen.

Session Viewer en SimView ServerSession Viewer en SimView Server zijn applicaties die tijdens de simulatie screenshots van de video- en patiรซntmonitorschermen registreren en bovendien een interface bieden voor de debriefing van uw sessie. Nadat een sessie is beรซindigd, worden de in LLEAP gegenereerde logbestanden voor de debriefing gekopieerd en samengevoegd met de videobestanden in Session Viewer of SimView Server.

Session Viewer wordt gewoonlijk uitgevoerd op de computer die ook voor LLEAP wordt gebruikt. SimView wordt uitgevoerd op een speciale computer in het lokale netwerk. Wanneer LLEAP voor het eerst wordt opgestart, wordt u gevraagd om een systeem op uw computer of in een lokaal netwerk voor de debriefing te selecteren. Dit kunt u naderhand weer wijzigen.

Overige applicatiesEr zijn nog meer programma's die in verband met de simulatiesessies worden gebruikt, zoals License Manager (licentiebeheerder) om de programmalicenties te beheren en Simulator Firmware & Network Wizard (reparatieprogramma voor de firmware van de simulator en het netwerk) voor het updaten van de firmware van de simulator of voor probleemoplossing bij netwerkproblemen.

SimDesignerSimDesigner is een applicatie waarmee u uw eigen, vooraf geprogrammeerde scenario's kunt configureren. Ook kan dit programma worden gebruikt voor de analyse van een scenario en het afdrukken van de grafische weergave ervan.

SimDesigner moet worden geรฏnstalleerd om bestaande applicatiebestanden van instructeurs tot een met LLEAP compatibel bestandsformaat te kunnen converteren.

Helpbestanden

Zie de Help-bestanden voor meer informatie over de LLEAP-software en andere applicaties:

1. Klik in Windows op <Start> <Alle programma's>.

2. Selecteer <Laerdal Simulation Home>.

3. Selecteer <Help>.

WebdownloadsGa naar www.laerdal.com/downloads om de nieuwste gebruikershandleiding en software te downloaden.

Page 143: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

141

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Simulatorinstallatie

Simulaties voorbereiden Nadat de SimJunior-simulator is gereed gemaakt en alle toepasselijke interactieve apparaten (de SimPad of de pc van de instructeur en patiรซntmonitor) zijn geconfigureerd en gebruiksklaar zijn, zijn er mogelijk de laatste voorbereidingen nodig voordat simulaties kunnen worden doorlopen met de SimJunior.

Tot de laatste voorbereidingen voor simulatie behoren de volgende activiteiten:

โ€ข Voorbereiding van het IO-been

โ€ข Toedienen van IV-vloeistoffen

โ€ข Draineren van overtollige IV-vloeistof

โ€ข Reinigen van de IV-arm

โ€ข Aansluiten van defibrillatieadapterplaten

โ€ข Aansluiten van de bloeddrukmanchet

โ€ข Vervangen van de pupillen

โ€ข Aansluiten van een externe compressor

โ€ข Veranderen van de instellingen voor de interne compressor

Voorbereiding van het IO-been Het rechterbeen van de simulator is bestemd voor het oefenen van vaardigheden in intraossale infusie. De anatomie van het rechterbeen omvat knie, tibia, tibiale tuberositeitplaats en plaats van de malleolus medialis. Het rechterbeen wordt geleverd met IV-slang en รฉรฉn IV-zak voor gebruik als reservoir tijdens infusie.

Extra benodigde hulpmiddelen:

โ€ข IV-zak en toedieningsset

โ€ข Gesimuleerd bloedconcentraat

โ€ข 35 cc spuit en 16 gauge intraossale naald

Om het IO-been te vullen en klaar te maken voor gebruik:

1. Til het been verticaal omhoog.

2. Open de plug bij de hiel.

3. Vul met een spuit het bot met ongeveer 240 tot 250 ml gesimuleerd bloed.

4. Bevestig de slang die is aangesloten op een IV-reservoirzak. (Gebruik zo nodig rolklemmen voor het openen en sluiten van de lijn om de drukopbouw te verlichten.)

5. Sluit de slang die in de reservoirzak loopt zodat gesimuleerd bloed in het bot achterblijft voor aspiratie.

6. Stop met de infusie als de reservoirzak vol is en vervang de zak door een lege zak.

Voordat u de simulator opslaat:

โ€“ Haal de IV-lijn en het reservoir los van de voet

โ€“ Laat alle vloeistof weglopen

โ€“ Berg het been los op zodat het aan de lucht kan drogen

Opmerking: Gebruik geen zoutoplossing. Dat kan de kwaliteit van het been verminderen. Gebruik gedestilleerd of gedeรฏoniseerd water om ophoping van mineralen te vermijden.

Toedienen van IV-vloeistoffen De rechter IV-arm wordt gebruikt voor training voor toediening van geneesmiddelen via een infuus, inbrengen van een infuus, infusie en bolus in perifere aderen van de onderarm, antecubitale fossa en dorsum van de hand.

Gebruik een naald 20 tot 22 gauge voor IV-simulatie. Gebruik ter voorkoming van verstopping van het IV-systeem uitsluitend gedestilleerd of gedeรฏoniseerd water voor het simuleren van IV-geneesmiddelen.

Page 144: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

142

Simulatorinstallatie

Draineren van overtollige IV-vloeistof Het IV-vloeistofsysteem is een open systeem. IV-vloeistof wordt afgevoerd zodra deze wordt toegediend.

Voorafgaand aan elke sessie:

1. Sluit de afloop (in de rechterarm van de simulator) aan op een afloopcontainer (zoals een infuuszak).

2. Laat overtollige vloeistof tijdens de simulatie weglopen in een container.

Reinigen van de IV-arm Reinig de IV-arm na elke sessie of gebruiksdag door hem door te spoelen met 60% isopropanol of 70% ethanol.

Installeren van de defibrillatieplaten De torso van de simulator is voorzien van twee schroefaansluitingen voor defibrillatorkabels. Schroef de schroeven van de defibrillator los en verwijder ze voordat u met defibrillatie begint.

De simulator wordt met twee defibrillatieadapterplaten geleverd. De defibrillatieadapterplaten moeten op hun plaats worden bevestigd voordat een echte defibrillator met defibrillatiepaddles wordt gebruikt. Schroef de adapterplaten stevig op hun plaats.

Tijdens defibrillatie Er kan een conventionele defibrillator (niet inbegrepen) op de SimJunior worden gebruikt. Tijdens defibrillatie kunnen de defibrillator en de simulator een schok veroorzaken. Alle standaard veiligheidsmaatregelen moeten worden genomen bij gebruik van een defibrillator op de simulator.

Waarschuwing: De simulator mag tijdens defibrillatie niet in contact zijn met elektrisch geleidende oppervlakken of voorwerpen.

Waarschuwingen:

โ€“ Defibrillatie mag uitsluitend op de aansluitingen voor de defibrillator worden uitgevoerd.

โ€“ Defibrilleer de simulator niet als de huid van de torso niet op zijn plaats zit.

Aansluiten van de bloeddrukmanchet

De simulator wordt geleverd met een speciale bloeddrukmanchet. Sluit de slang voor gebruik aan op de witte BP-connector aan de achterzijde van de Link Box.

Opmerking: De luidspreker voor de bloeddruk van de simulator bevindt zich in de linker antecubitale fossa, hieronder omcirkeld. De radiale en de brachiale pols zijn te vinden in de rechthoekige gebieden.

IJken van de bloeddrukmanchet in LLEAP

1. Kies <Tools> uit het menu

2. Kies <Simulator Setup> (simulatorinstallatie) uit het menu Tools

3. Kies <Calibrate Blood Pressure> (bloeddruk kalibreren) uit het submenu

4. Volg de instructies van de wizard op het scherm om de kalibratie uit te voeren

IJken van de bloeddrukmanchet in SimPad

1. Kies <Calibrate> (kalibreren) uit het menu.

2. Kies <Calibrate BP> (bloeddruk kalibreren) uit de vervolgkeuzelijst.

3. Volg de instructies van de wizard op het scherm om de kalibratie uit te voeren.

Page 145: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

143

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Simulatorinstallatie

Vervangen van de pupillen

De SimJunior wordt geleverd met normale pupillen in de ogen. Een afzonderlijke set met plastic pupil-inzetstukken (vernauwd en verwijd) wordt bij de SimJunior geleverd.

Om de pupillen te vervangen:

1. Sper voorzichtig de oogleden wijd open, en zorg ervoor dat u de huid van het simulatorgezicht niet beschadigt.

2. Verwijder de pupil behoedzaam uit het oog met behulp van het instrument met zuignap dat bij de kit hoort of met de rand van uw vingernagel.

3. Vervang de pupil door de gewenste inzet met behulp van het instrument met de zuignap of door de inzet zachtjes op zijn plaats te duwen.

Gebruik van een externe compressor De externe compressor wordt aangesloten op de doorzichtige slang in de kabelbundel die uit de rechterzij van de simulator komt. Bij het gebruik van een externe compressor kunt u de interne compressor uitschakelen vanuit SimPad of LLEAP.

Neem voor meer informatie over externe compressors en met de SimJunior compatibele regelpanelen contact op met uw lokale Laerdal vertegenwoordiger.

In- of uitschakelen van de interne compressor in SimPad

1. Start <Manual Mode> (handmatige modus), kies een thema en start de sessie.

2. Kies <Miscellaneous> (diversen) uit het onderste menu.

3. Kies <Compressor> uit het submenu.

4. Maak de gewenste wijzigingen in het dialoogvenster en klik op OK.

In-of uitschakelen van de interne compressor in LLEAP

1. Kies <Tools> uit het menu.

2. Kies <Simulator Setup> (simulatorinstallatie) uit het menu Tools.

3. Kies <Internal compressor> (interne compressor) uit het submenu.

4. Maak de gewenste wijzigingen in het dialoogvenster en klik op OK.

Page 146: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

144

Opmerking: Zie voor informatie over accessoires en reserveonderdelen de paragraaf Reserveonderdelen en accessoires

Voorafgaand aan opslag en verzending

โ€“ Spoel de IV-arm door met 60% isopropanol of 70% ethanol. Open het ventiel onderaan de rechtervoet van de simulator.

Onderhoud

Onderhoud na elke simulatiesessie De volgende preventieve maatregelen zijn vereist voor een lange levensduur van de SimJunior simulator.

โ€“ Schakel de SimPad, Link Box en de pc's uit

โ€“ Laad zo nodig de accuโ€™s op

โ€“ Spoel het IV-armsysteem door en laat het IO-been leeglopen (laat de plug onderaan het been open)

โ€“ Spoel na elke sessie waarin de IV-arm is gebruikt de IV-arm door met 60% isopropanol of 70% ethanol

โ€“ Veeg de huid af met een vochtige doek

โ€“ Verwijder natte kleding of beddengoed

โ€“ Verwijder tape-resten met een vochtige doek of ontsmettingsalcohol

โ€“ Vervang (afhankelijk van het gebruik van de simulator) modules die versleten of beschadigd zijn

โ€“ Vervang kabels of aansluitingen die zichtbare beschadiging vertonen

โ€“ Onderhoud moet met regelmatige tussenpozen worden uitgevoerd door gekwalificeerd personeel

Voer altijd onderhoud uit:

โ€“ Als er vloeistof in of op de simulator is gemorst

โ€“ Na gebruik in een stoffige omgeving

Page 147: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

145

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Onderhoud

Openen van de torso

Open de torso van de simulator om procedures uit te voeren zoals:

โ€“ Bevestigen of vervangen van ledematen

โ€“ Vervangen van de accu van de simulator

โ€“ Vervangen van het ballonnetje voor de borstkasbeweging en de long

โ€“ Vervangen van de huid van de torso

โ€“ Voor algemene inspectie

Waarschuwing: Open de torso van links naar rechts en maak de huid voorzichtig los. Til de huid van de torso voorzichtig op, anders kunnen de kabels aan de borst beschadigen.

1. Maak de huid van de torso aan de linkerkant en bij beide schouders los.

Vervangen van de accu van de simulator

2. Vouw de huid van de torso naar rechts.

3. Ontkoppel de aansluitkabel van de defibrillator.

4. De aansluitkabel van de defibrillator moet worden ontkoppeld aan de rechterzijde van de simulator, onder de borstvorm.

Opmerking: Maak de slangen en kabels waarmee het schuim van de maag aan de simulator vastzit NIET los.

5. Vervang de huid van de torso door stap 1-4 in omgekeerde volgorde uit te voeren.

1. Open de torso van de simulator.

2. Schuif de accu uit de accubevestigingsband.

3. Trek de accustroomaansluiting omhoog vanuit de binnenkant van de simulator. Maak de stroomaansluiting van de accu los.

4. Til de accu uit de simulator.

5. Vervang de accu door een opgeladen accu of installeer een nieuwe, door Laerdal goedgekeurde SimJunior accu.

6. Sluit de accu aan op de simulator.

7. Vervang de huid van de torso

Page 148: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

146

Onderhoud

Opladen van de accu van de simulator

De accu van de simulator laadt zichzelf op als hij in bedrijf is. Zo nodig kan de accu van de simulator worden opgeladen met een optionele stroomadapter.

1. Schakel de simulator via de Link Box uit.

2. Verwijder de accu uit de simulator.

3. Sluit een goedgekeurde externe acculader (met een snoer dat voldoet aan de lokale specificatie) aan op de onderzijde van de accu van de simulator. Steek de stekker van de acculader in een wandstopcontact.

4. Vervang de accu in de simulator als deze is opgeladen.

Vervangen van het ballonnetje voor de borstkasbeweging Het ballonnetje voor de borstkasbeweging is te vinden in het onderste uiteinde van de borstplaat, midden onder de longen.

1. Maak de huid van de torso los om de borstplaat bloot te leggen. Zie De torso openen.

2. Ontkoppel de doorzichtige slang van de longen en verwijder ze. Zie voor meer informatie Vervangen van de longen

3. Ontkoppel de doorzichtige slang van het ballonnetje voor de borstkasbeweging.

4. Gooi het oude ballonnetje weg.

5. Breng het nieuwe ballonnetje aan.

6. Sluit de slang weer aan op het nieuwe ballonnetje.

7. Sluit de torso en maak de huid van de torso weer vast.

Vervangen van de longen Als er lekkage optreedt, moeten de longen (in de borstholte) worden vervangen.

1. Maak de huid van de torso los.

2. Ontkoppel de doorzichtige slang onderaan iedere zijde van de longen en verwijder ze. Raadpleeg voor stap 2 de illustratie bij Vervangen van het ballonnetje voor de borstkasbeweging.

3. Ontkoppel de klem van de longen van het bovenste middendeel.

4. Trek het bovenste middendeel van de longen voorzichtig uit de houder omhoog.

5. Voer het proces omgekeerd uit om de nieuwe longen te installeren.

Page 149: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

147

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Vervangen van de huid van de simulator De huid van de simulator moet wellicht worden vervangen als deze gescheurd, doorboord of gevlekt is.

Huid torso:

Zie De torso openen om de torsohuid van de simulator te vervangen.

Armhuid:

Vervangen van de huid van de arm van de simulator:

1. Verwijder de oude huid van de simulatorarm door deze af te stropen langs de hand of door *de huid los te snijden.

Nieuwe arm bevestigen:

Onderhoud

Vervangen van de rechter IV-arm

1. Open de torso, zie De torso openen.

2. Verwijder de oude arm door de bout los te draaien waarmee de arm aan de schouder van de simulator vastzit.

3. Zorg dat de schouderschroef los genoeg zit om de as van de arm er gemakkelijk uit te laten schuiven.

4. Gooi de oude arm weg conform de aangegeven richtlijnen.

1. Zorg dat de schouderschroef los genoeg zit om de as van de arm er gemakkelijk in te laten schuiven.

2. Sluit de arm aan op de overeenkomstige aansluitingspunten in de torso.

3. Druk de as van de arm voorzichtig in de schouderbeugel, zodat de as in รฉรฉn vlak ligt met de binnenzijde van de beugel.

4. Draai de schouderschroef vast met een inbussleutel.

Vervangen van het rechterbeen (IO-been) Het rechteronderbeen losmaken:

1. Zorg dat er geen vloeistof meer in het been zit (laten afvloeien).

2. Verwijder het oude IO-been door de bout los te schroeven waarmee het been aan de dij vastzit.

3. Schuif het IO-onderbeen uit de dij.

4. Gooi het oude IO-been weg conform de aangegeven richtlijnen.

Voer het bovenstaande proces omgekeerd uit om het nieuwe IO-been te bevestigen.

Waarschuwing: *Maak geen gaatjes of kerven in de 'binnenarm'.

2. Gooi de oude huid weg.

3. Smeer de binnenzijde van nieuwe armhuid in met vloeibaar reinigingsmiddel gemengd met water.

4. Smeer de 'binnenarm' in met een mengsel van milde vloeibare zeep en water.

5. Schuif de hand van de simulator in de huid.

6. Beweeg de huid over de vingers (net als bij een handschoen).

7. Breng de huid omhoog, over de 'binnenarm'.

Page 150: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

148

Probleemoplossing

Systeeminstallatie

Probleem

โ€ข Verloren gegevens of totale systeemstoring (algeheel systeemfalen).

Mogelijke oplossing

โ€ข Neem contact op met het plaatselijke Laerdal servicecentrum als het systeem automatisch wordt afgesloten of alle gegevens verloren gaan of niet meer betrouwbaar zijn.

LLEAPโ€ข Zie Software Help Files (de helpbestanden van software) >

LLEAP > Troubleshooting Guide (gids voor probleemoplossing) (Help is toegankelijk vanuit Laerdal Simulation Home).

Laerdal Patient Monitorโ€ข Zie Software Help Files (de helpbestanden van software) >

Laerdal Patient Monitor > Troubleshooting Guide (gids voor probleemoplossing). (Help is toegankelijk vanuit Laerdal Simulation Home)

Debriefing- en video-opnamenโ€ข Zie de paragraaf voor Troubleshooting (probleemoplossing)

in de SimView Help (toegankelijk vanuit een link onderaan het scherm in SimView) of de Troubleshooting Guide (gids voor probleemoplossing) van de SessionViewer Help (toegankelijk vanuit Laerdal Simulation Home)

Simulator

Probleem

โ€ข Onvoorspelbaar gedrag.

Mogelijke oplossingen

โ€ข Storingen in de simulator kunnen veroorzaakt worden door losse kabels, slangen of aansluitingen. Open de torso en controleer of onderdelen ontkoppeld lijken te zijn of lekken. Zie de paragraaf: Simulatorinstallatie - Het openen van de torso.

โ€ข Schakel bij lekkage van vloeistoffen de simulator uit en neem contact op met de technische dienst van Laerdal.

Luchtwegbesmetting

Probleem

โ€ข De luchtwegen van de simulator zijn besmet als gevolg van mond-op-mond beademing.

Mogelijke oplossing

โ€ข Reinig de buitenzijde van de simulator met de speciale simulatordoekjes. Reinig de binnenkant van de mondholte met de speciale simulatordoekjes. Vervang de longen, zie paragraaf: Onderhoud - Vervangen van de longen.

Borstkasbeweging

Probleem

โ€ข De borstkas van de simulator komt niet omhoog.

Mogelijke oplossingen

โ€ข Controleer of de simulator is aangesloten op het elektriciteitsnet.

โ€ข Controleer in SimPad of LLEAP of โ€“ awRR niet op nul is ingesteld

โ€“ Het omhoog bewegen van de borstkas niet is ingesteld op UIT

โ€“ ECG is ingesteld op een perfunderend ritme.

โ€“ Luchtwegcomplicaties zoals maximale luchtweerstand of laryngospasme niet zijn ingesteld.

โ€“ Controleer of de geรฏntegreerde compressor in LLEAP is ingeschakeld. Zie paragraaf: Uitschakelen van de interne compressor.

โ€ข Controleer of een externe persluchtbron is uitgeschakeld en de luchtslang van de simulator is losgekoppeld.

โ€ข De interne compressor kan oververhit zijn. Wacht ongeveer 20 minuten tot hij is afgekoeld.

โ€ข De borstkasbeweging is ingesteld op bilateraal (bijvoorbeeld als een ET-tube te ver is ingebracht in de bronchiรซn).

โ€ข De ballon voor de borstkasbeweging lekt of de slang ernaartoe is gedraaid, geknikt of losgekomen. Vervang de ballon voor de borstkasbeweging als deze lekt; zie de paragraaf Onderhoud: Vervangen van het ballonnetje voor de borstkasbeweging

โ€ข Controleer de luchtslang op lekken; controleer of alle aansluitingen intact zijn. Vervang het slangengedeelte bij lekkage.

โ€ข Lichte borstbewegingen en de interne compressor draait continu. De interne compressor kan zijn versleten. Neem contact op met de technische dienst van Laerdal.

Longen

Probleem

โ€ข De longen werken niet goed

Mogelijke oplossingen

โ€ข Open de torso en de borstplaat. Controleer of de longen vrij kunnen uitzetten en niet beperkt worden door kabels.

โ€ข Controleer of de longzak goed is bevestigd en of de slangen niet gedraaid zitten.

โ€ข Controleer of de longzak in een horizontale positie ligt en op de juiste wijze is geplaatst.

Page 151: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

149

Sim

ulat

ieso

ftw

are

Sim

ulat

orin

stal

latie

O

nder

houd

R

eser

veon

derd

elen

en

acc

esso

ires

Sp

ecifi

catie

s

Inle

idin

g

Prob

leem

oplo

ssin

g

Probleemoplossing

โ€ข Controleer op beschadigingen of scheuren in de longzak.

โ€ข Controleer of er geen obstructies in de luchtwegen van de simulator zitten die de luchtstroom kunnen blokkeren.

โ€ข Neem contact op met de technische dienst van Laerdal als er geen verandering is bij het instellen van de longcompliance.

โ€ข Neem contact op met de technische dienst van Laerdal als er geen verandering is in de longweerstand.

Mechanisch geluid tijdens auscultatieKlik in LLEAP op <auscultatiefocus>.

Polsslagen (radiaal en brachiaal)

Probleem

โ€ข Pols niet voelbaar

Mogelijke oplossingen

โ€ข Het kan zijn dat de huid te strak over de pols-units ligt - herschik de huid en start opnieuw op.

โ€ข Zorg dat de bloeddruk is ingesteld op minstens 60 systolisch.

โ€ข Zorg dat de compressor AAN staat.

Opmerking: Indien de via de polsslagader meetbare bloeddruk onder 60 is ingesteld, kan de perifere polsslag verdwijnen.

De simulator is automatisch uitgeschakeld

Probleem

โ€ข De simulator reageert niet.

Oplossing

1. Schakel de Link Box uit.

2. Schakel de SimPad uit, of schakel de pc van de instructeur uit als u LLEAP gebruikt.

3. Herstart alles.

Neem contact op met de vertegenwoordiger van Laerdal als de simulator nog steeds niet reageert.

Page 152: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

150

Opmerkingen

Page 153: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

151

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Specificaties

Totaalafmetingen Lengte/breedte (alleen simulator): 120 cm x 42,5 cm Gewicht (alleen simulator): 11,36 kg

Simulatorstroom Extern vermogen: Ingangsvoltage 9 VDC, 1,5 A Interne accu: 7,4 V, 4,4 Ah, Lithium-Ion

Gebruik alleen externe stroomvoorziening en accu's die zijn goedgekeurd voor SimJunior.

Luchtdruk Intern luchtreservoir : Max 6 psi Externe luchtaansluiting: Max 16 psi

Temperatuurlimieten Bedrijfstemperatuur: +4 ยบC tot 40 ยบC Opslagtemperatuur: -15 ยบC tot 50 ยบC

Omgeving - Alleen simulator Relatieve vochtigheid: 20% - 90% (niet-condenserend) NIET in open lucht gebruiken bij natte omstandigheden. Niet getest met zoutnevel.

RF-communicatie Werkingsbereik: max. 10 m

Materiaallijst voor simulator Kleding: Katoen, nylon Huid en luchtwegen: PVC Externe harde plastics: PVC, ABS Plastic aan de binnenkant: Siliconen, TPU, PVC, nitriel ABS, POM,

nylon + GF epoxy-polyurethaan Metaalcomponenten: Aluminium, koper, staal

Minimale computervereisten

โ€ข Intel i-core generatie 3 of recenter

โ€ข Score van meer dan 3000 PassMark - CPU Mark

โ€ข 4 GB RAM

โ€ข 120 GB harddiskruimte

โ€ข Ten minste 1366 x 768

โ€ข Headset met microfoon

โ€ข USB poorten โ€“ 2

Minimale softwarevereisten

โ€ข Windows 7 of Windows 8

โ€ข 100% DPI

Reinigingsvloeistoffen Gebruik voor het reinigen van de simulator een van de volgende middelen:

โ€“ 60% isopropanol

โ€“ 70% ethanol

โ€“ Milde oplossing van vloeibare zeep en water

IV-vloeistoffen Gebruik uitsluitend gedestilleerd of gedeรฏoniseerd water voor het simuleren van IV- en IO-vloeistoffen.

Page 154: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

152

Opmerkingen

Page 155: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

153

Sim

ulat

ieso

ftw

are

Si

mul

ator

inst

alla

tie

Ond

erho

ud

Res

erve

onde

rdel

en

en a

cces

soir

es

Spec

ifica

ties

In

leid

ing

Pr

oble

emop

loss

ing

Reserveonderdelen en accessoires

Reserveonderdelen en accessoiresVoor de nieuwste versie van Reserveonderdelen en accessoires, gaat u naar www.laerdal.com

Page 156: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

154

Opmerkingen

Page 157: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

PL

155

Czynnoล›ci konserwacyjne 166

โ€“ Czynnoล›ci obsล‚ugowe po kaลผdej sesji symulacji 166 โ€“ Otwieranie korpusu 167 โ€“ Wymiana akumulatora symulatora 167 โ€“ ลadowanie akumulatora symulatora 168 โ€“ Wymiana worka do symulacji unoszenia

klatki piersiowej 168 โ€“ Wymiana worka pล‚ucnego 168 โ€“ Wymiana powล‚ok skรณrnych symulatora 169 โ€“ Wymiana prawego ramienia z dostฤ™pem doลผylnym 169 โ€“ Wymiana prawej nogi z dostฤ™pem ล›rรณdkostnym 169

Rozwiฤ…zywanie problemรณw 170

Wstฤ™p 156

โ€“ Informacje dotyczฤ…ce regulacji prawnych 156 โ€“ Ogรณlne zasady konserwacji symulatora 157โ€“ Widok ogรณlny symulatora SimJunior 159 โ€“ Funkcje symulatora SimJunior 160

Konfiguracja symulatora 163

โ€“ Przygotowanie do symulacji 163โ€“ Przygotowanie koล„czyny dolnej z dostฤ™pem

ล›rรณdkostnym 163 โ€“ Podanie pล‚ynรณw we wlewie doลผylnym 163 โ€“ Odprowadzanie nadmiaru pล‚ynu podawanego doลผylnie 164 โ€“ Czyszczenie ramienia z dostฤ™pem doลผylnym 164 โ€“ Instalacja pล‚ytek ze zล‚ฤ…czami defibrylatora 164 โ€“ Podล‚ฤ…czanie mankietu do pomiaru ciล›nienia krwi 164 โ€“ Kalibracja mankietu do pomiaru ciล›nienia krwi w LLEAP 164 โ€“ Kalibracja mankietu do pomiaru ciล›nienia krwi w SimPad 164โ€“ Wymiana ลบrenic 165 โ€“ Uลผywanie sprฤ™ลผarki zewnฤ™trznej 165

Specyfikacje 173

Oprogramowanie do symulacji 162

โ€“ Komputer instruktora 162 โ€“ Licencja oprogramowania 162 โ€“ Laerdal Simulation Home 162 โ€“ LLEAP 162 โ€“ Voice Conference Application 162 โ€“ Patient Monitor 162 โ€“ Session Viewer i SimView Server 162 โ€“ Inne aplikacje 162 โ€“ SimDesigner 162 โ€“ Pliki pomocy 162 โ€“ Do pobrania z internetu 162

Czฤ™ล›ci zamienne i akcesoria 175

Spis treล›ci

Page 158: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

156

Akumulator litowo-jonowy

Wstฤ™p

Wprowadzenie do symulatora SimJuniorโ„ข Symulator SimJunior jest realistycznym, peล‚nowymiarowym symulatorem pacjenta pediatrycznego opracowanym przez firmฤ™ Laerdal we wspรณล‚pracy z Amerykaล„skฤ… Akademiฤ… Pediatrii. Symulator SimJunior moลผna stosowaฤ‡ do indywidualnych lub zespoล‚owych szkoleล„ pracownikรณw sล‚uลผby zdrowia o rรณลผnych specjalizacjach medycznych.

Symulator SimJunior jest dostarczany w postaci w peล‚ni zmontowanej. Nie ma potrzeby montowania czฤ™ล›ci symulatora.

Szczegรณล‚owe informacje na temat przygotowania symulatora SimJunior do sesji szkoleniowej moลผna znaleลบฤ‡ w sekcji โ€žKonfiguracja symulatoraโ€.

Symulator SimJunior โ€” pomoc Instrukcja uลผytkowania (DFU) Instrukcje krok po kroku oraz ilustracje dotyczฤ…ce uลผytkowania symulatora SimJunior.

Oryginalne podrฤ™czniki uลผytkownika udostฤ™pniane przez producenta Naleลผy przestrzegaฤ‡ instrukcji zawartych we wszystkich instrukcjach uลผytkowania oraz postฤ™powaฤ‡ zgodnie z pouczeniami znajdujฤ…cymi siฤ™ na etykietach umieszczonych przez producenta. Instrukcja uลผytkowania symulatora SimJunior nie zastฤ™puje ani nie uchyla instrukcji udzielonych przez producenta.

Skrรณcona instrukcja instalacji symulatora SimJunior

Instrukcja krok po kroku dotyczฤ…ca instalacji symulatora SimJunior.

Instrukcja uลผytkowania (DFU) urzฤ…dzenia SimPad Instrukcja uลผytkowania urzฤ…dzenia SimPad zawiera instrukcje dotyczฤ…ce uลผytkowania urzฤ…dzeล„ Link Box i SimPad z symulatorem SimJunior.

Pliki pomocy aplikacji LLEAP (Laerdal Learning Application)Dostฤ™p do plikรณw pomocy do aplikacji LLEAP moลผna uzyskaฤ‡ z poziomu Laerdal Simulation Home, patrz Laerdal Simulation Home.

Tematy pomocy obejmujฤ… nastฤ™pujฤ…ce zagadnienia:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor.

Pomoc techniczna W celu uzyskania pomocy technicznej naleลผy skontaktowaฤ‡ siฤ™ z centrum pomocy technicznej firmy Laerdal.

Do pobrania z internetu Najnowszฤ… Instrukcjฤ™ uลผytkowania oraz nowsze wersje oprogramowania obsล‚ugujฤ…cego symulacjฤ™ moลผna pobraฤ‡ ze strony: www.laerdal.com/downloads

Materiaล‚y dostฤ™pne w serwisie SimCenter Serwis SimCenter zapewnia ล‚atwy dostฤ™p do sprawdzonych materiaล‚รณw oferowanych przez ล›wiatowych ekspertรณw w dziedzinie symulacji, uล‚atwiajฤ…c korzystanie z ich doล›wiadczeล„ i maksymalizujฤ…c korzyล›ci pล‚ynฤ…ce ze szkoleล„. Moลผna tam znaleลบฤ‡ rรณลผnorodne scenariusze opracowane specjalnie do stosowania z symulatorem SimJunior. Zapraszamy do odwiedzenia strony www.mysimcenter.com i sprawdzenia moลผliwoล›ci optymalizacji szkoleล„.

Informacje dotyczฤ…ce regulacji prawnych

Federal Communications Commission StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:โ€ข Reorient or relocate the receiving antenna.โ€ข Increase the separation between the equipment and receiver.โ€ข Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.โ€ข Consult the dealer or an experienced radio/TV technician for help.

Przestroga Zmiany lub modyfikacje, ktรณre nie zostaล‚y wyraลบnie zaakceptowane przez stronฤ™ odpowiedzialnฤ… za zgodnoล›ฤ‡ z przepisami, mogฤ… skutkowaฤ‡ wygaล›niฤ™ciem prawa uลผytkownika do dalszej eksploatacji urzฤ…dzenia.

Akumulatory litowo-jonowe naleลผy poddaฤ‡ recyklingowi.

Laerdal Medical AS niniejszym oล›wiadcza, ลผe oznaczony symbolem CE produkt speล‚nia zasadnicze wymagania i inne istotne przepisy dyrektywy 1999/5/WE.

Utylizowaฤ‡ zgodnie z lokalnymi wymaganiami i przepisami.

Zrzeczenie siฤ™ odpowiedzialnoล›ci Szkolenie przy uลผyciu symulatora SimJunior powinno odbywaฤ‡ siฤ™ pod kontrolฤ… odpowiednio przeszkolonego personelu technicznego lub medycznego zaznajomionego z zasadami szkoleniowymi oraz ogรณlnie przyjฤ™tymi procedurami medycznymi. Podobnie jak w przypadku innych symulatorรณw oraz podobnych urzฤ…dzeล„ szkoleniowych uลผytkownik moลผe spotkaฤ‡ siฤ™ z przybliลผeniami, odstฤ™pstwami i niedokล‚adnoล›ciami w odwzorowaniu cech anatomicznych oraz w zakresie modelowania procesรณw fizjologicznych. Wziฤ…wszy powyลผsze pod uwagฤ™, firma Laerdal nie gwarantuje, ลผe wszystkie funkcje zostaล‚y odwzorowane w sposรณb caล‚kowicie dokล‚adny.

Page 159: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

C

zynn

oล›ci

ko

nser

wac

yjne

C

zฤ™ล›c

i zam

ienn

e i a

kces

oria

Spec

yfika

cje

W

stฤ™p

Ro

zwiฤ…

zyw

anie

pr

oble

mรณw

157

Globalna gwarancja Informacje na temat gwarancji moลผna znaleลบฤ‡ w broszurze poล›wiฤ™conej globalnej gwarancji firmy Laerdal lub na stronie internetowej www.laerdal.com.

Kraj pochodzenia โ€” symulator SimJunior wyprodukowano w USA.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Wstฤ™p

Ogรณlne zasady konserwacji symulatora W celu uzyskania optymalnych parametrรณw eksploatacyjnych i  zapewnienia maksymalnie dล‚ugiego okresu eksploatacji symulatora i  jego elementรณw naleลผy postฤ™powaฤ‡ zgodnie z instrukcjami podanymi poniลผej.

Ogรณlne zasady konserwacji

Aby utrzymaฤ‡ powล‚oki skรณrne symulatora w jak najlepszym stanie, przed uลผyciem naleลผy myฤ‡ rฤ™ce oraz ukล‚adaฤ‡ symulator na czystej powierzchni. Firma Laerdal zaleca, aby:

โ€“ stosowaฤ‡ rฤ™kawiczki podczas odgrywania scenariuszy symulacyjnych. Naleลผy unikaฤ‡ uลผywania kolorowych rฤ™kawiczek z  tworzyw sztucznych, gdyลผ mogฤ… one powodowaฤ‡ odbarwienia skรณry symulatora.

โ€“ unikaฤ‡ stosowania flamastrรณw, pisakรณw tuszowych, acetonu, jodyny i innych plamiฤ…cych preparatรณw w pobliลผu symulatora. Naleลผy pamiฤ™taฤ‡, aby nie umieszczaฤ‡ symulatora na gazetach lub kolorowym papierze. Powstaล‚e w ten sposรณb plamy mogฤ… mieฤ‡ charakter trwaล‚y.

โ€“ czyล›ciฤ‡ skรณrฤ™ symulatora ล‚agodnym mydล‚em i wodฤ….

Z uwagi na brak moลผliwoล›ci naleลผytego zdezynfekowania drรณg oddechowych podczas uลผywania symulatora nie naleลผy podejmowaฤ‡ prรณb stosowania nastฤ™pujฤ…cych technik:

โ€“ oddychanie usta-usta/usta-maska,

โ€“ wprowadzanie do manekina sztucznych wymiocin lub pล‚ynรณw w celu ich odessania.

โ€“ Jeล›li sesja szkoleniowa obejmuje podawanie pล‚ynรณw we wlewie doลผylnym, natychmiast po szkoleniu naleลผy oprรณลผniฤ‡ ramiฤ™ z dostฤ™pem doลผylnym z wprowadzonych pล‚ynรณw.

โ€“ Naleลผy uลผywaฤ‡ wyล‚ฤ…cznie lubrykantu do drรณg oddechowych firmy Laerdal, stosujฤ…c go w niewielkich iloล›ciach.

โ€“ Naleลผy opล‚ukaฤ‡, oczyล›ciฤ‡ i osuszyฤ‡ moduล‚y symulatora.

โ€“ Ponownie zaล‚oลผyฤ‡ skรณrฤ™ tuล‚owia i posypaฤ‡ jej wewnฤ™trznฤ… powierzchniฤ™ talkiem, aby zmniejszyฤ‡ tarcie. Nie naleลผy wprowadzaฤ‡ talku do wnฤ™trza klatki piersiowej symulatora.

Otoczenie W niskiej temperaturze otoczenia przed uruchomieniem symulatora naleลผy odczekaฤ‡, aลผ osiฤ…gnie on temperaturฤ™ pokojowฤ….

Aby uniknฤ…ฤ‡ przegrzania i zmniejszyฤ‡ zuลผycie:

โ€“ podczas eksploatacji w temperaturach przekraczajฤ…cych 40ยฐC zawsze naleลผy pozostawiฤ‡ symulator do ostygniฤ™cia pomiฤ™dzy sesjami szkoleniowymi.

โ€“ podczas uลผytkowania na ล‚รณลผku symulator nie powinien byฤ‡ przykryty ciฤ™ลผkฤ… poล›cielฤ…, ktรณra uniemoลผliwia oddawanie ciepล‚a

Ogรณlne zasady postฤ™powania z symulatorem W celu unikniฤ™cia obraลผeล„ uลผytkownikรณw lub uszkodzenia produktu naleลผy przedsiฤ™wziฤ…ฤ‡ nastฤ™pujฤ…ce ล›rodki ostroลผnoล›ci:

โ€“ wprowadzanie pล‚ynรณw do wnฤ™trza symulatora powinno odbywaฤ‡ siฤ™ wyล‚ฤ…cznie w sposรณb opisany w niniejszym dokumencie,

โ€“ przed przystฤ…pieniem do wprowadzania jakichkolwiek instrumentรณw, rurek lub urzฤ…dzeล„ do drรณg oddechowych naleลผy nawilลผyฤ‡ drogi oddechowe jamy ustnej i nosowej lubrykantem dostarczonym wraz z symulatorem, przed uลผyciem naleลผy rรณwnieลผ nawilลผyฤ‡ instrumenty i rurki,

โ€“ podczas wentylacji do wnฤ™trza symulatora pacjenta nie wolno podawaฤ‡ nawilลผanego powietrza,

โ€“ nie naleลผy uลผywaฤ‡ symulatora, gdy rurki wewnฤ™trzne oraz przewody sฤ… rozล‚ฤ…czone,

โ€“ nie wolno uลผywaฤ‡ symulatora SimJunior na zewnฤ…trz w wilgotnym otoczeniu, gdyลผ moลผe siฤ™ to wiฤ…zaฤ‡ z ryzykiem poraลผenia prฤ…dem lub uszkodzenia symulatora,

โ€“ stosowanie defibrylatora w temperaturze powyลผej 35ยฐC moลผe spowodowaฤ‡ przegrzanie.

Ostrzeลผenie: nie wolno stosowaฤ‡ automatycznych urzฤ…dzeล„ do uciskania klatki piersiowej symulatora.

Uwaga, lateks: Ten produkt zawiera naturalny lateks, ktรณry moลผe wywoล‚ywaฤ‡ reakcje alergiczne u osรณb uczulonych.

Zagroลผenia zwiฤ…zane z defibrylacjฤ… Symulator SimJunior umoลผliwia prowadzenie zabiegรณw defibrylacji.

W tym celu moลผna zastosowaฤ‡ standardowy defibrylator. Podczas wykonywania zabiegu defibrylacji z uลผyciem symulatora istnieje ryzyko poraลผenia prฤ…dem. Naleลผy zachowaฤ‡ wszystkie standardowe ล›rodki bezpieczeล„stwa podczas stosowania defibrylatora z symulatorem.

โ€ข Naleลผy zapoznaฤ‡ siฤ™ i postฤ™powaฤ‡ zgodnie z doล‚ฤ…czonymi instrukcjami dotyczฤ…cymi bezpieczeล„stwa oraz instrukcjami uลผytkowania defibrylatora i jego akcesoriรณw.

โ€ข Naleลผy postฤ™powaฤ‡ zgodnie z protokoล‚em defibrylacji, uwaลผajฤ…c, by nie dopuล›ciฤ‡ do kontaktu miฤ™dzy ล‚yลผkami zewnฤ™trznymi defibrylatora i powierzchniฤ… elektrod podczas defibrylacji. Moลผna stosowaฤ‡ defibrylacjฤ™ o maksymalnej wartoล›ci do 300 J.

โ€ข Nieprzestrzeganie ล›rodkรณw ostroลผnoล›ci moลผe spowodowaฤ‡ obraลผenia ciaล‚a lub ล›mierฤ‡.

Dodatkowe informacje moลผna znaleลบฤ‡ w oryginalnej instrukcji uลผytkowania defibrylatora.

Ostrzeลผenia:

โ€“ Podczas wykonywania zabiegu defibrylacji naleลผy uลผywaฤ‡ zล‚ฤ…czy defibrylatora lub pล‚ytek stykowych umieszczonych na klatce piersiowej symulatora. Nie wolno wykorzystywaฤ‡ zล‚ฤ…czy do EKG, ktรณre przeznaczone sฤ… wyล‚ฤ…cznie do monitorowania  EKG. Defibrylacja przez zล‚ฤ…cza EKG spowoduje uszkodzenia wewnฤ™trznych ukล‚adรณw elektronicznych symulatora oraz moลผe wywoล‚aฤ‡ obraลผenia ciaล‚a uลผytkownika.

โ€“ Nie wolno przeprowadzaฤ‡ zabiegu defibrylacji na WYลฤ„CZONYM lub nieprawidล‚owo dziaล‚ajฤ…cym symulatorze pacjenta.

Page 160: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

158

Wstฤ™p

Aby zapobiec przegrzaniu symulatora podczas defibrylacji, nie naleลผy przekraczaฤ‡ sekwencji 3 wyล‚adowaล„ defibrylacyjnych w ciฤ…gu 45 sekund, po ktรณrych powinna nastฤ™powaฤ‡ trwajฤ…ca 1 minutฤ™ resuscytacja krฤ…ลผeniowo-oddechowa. Po upล‚ywie 30  minut naleลผy zaprzestaฤ‡ stosowania wyล‚adowaล„ na co najmniej 15 minut przed rozpoczฤ™ciem kolejnej sekwencji. Nie naleลผy powtarzaฤ‡ sekwencji przez okres dล‚uลผszy niลผ 4 godziny. Nie naleลผy rรณwnieลผ generowaฤ‡ wiฤ™cej niลผ dwรณch wyล‚adowaล„ o mocy 300 dลผuli na minutฤ™.

Ostrzeลผenia:

โ€“ Podczas defibrylacji symulator nie moลผe stykaฤ‡ siฤ™ z powierzchniami lub przedmiotami przewodzฤ…cymi prฤ…d.

โ€“ Unikaฤ‡ stosowania w ล›rodowisku, w ktรณrym znajdujฤ… siฤ™ substancje palne. Na przykล‚ad naleลผy unikaฤ‡ defibrylacji w atmosferze bogatej w czysty tlen. W przypadku stosowania stฤ™ลผonego tlenu w pobliลผu symulatora naleลผy zapewniฤ‡ dobrฤ… wentylacjฤ™.

โ€“ Korpus symulatora musi zawsze byฤ‡ suchy. โ€“ Przed przystฤ…pieniem do defibrylacji naleลผy poczekaฤ‡ na

aklimatyzacjฤ™ symulatora. Nagล‚e zmiany temperatury mogฤ… wywoล‚ywaฤ‡ kondensacjฤ™ na elementach elektronicznych, co moลผe wiฤ…zaฤ‡ siฤ™ z ryzykiem poraลผenia.

โ€“ Aby zapobiec pozostawianiu ล›ladรณw na skรณrze klatki piersiowej przez elektrody, nie naleลผy stosowaฤ‡ ลผeli przewodzฤ…cych ani podkล‚adek przewodzฤ…cych do defibrylacji, przeznaczonych do uลผytku u pacjentรณw.

โ€“ Zbyt mocne dociskanie zล‚ฤ…czy defibrylatora podczas defibrylacji moลผe powodowaฤ‡ wyล‚adowania ล‚ukowe i korozjฤ™ wลผerowฤ….

โ€“ Nie naleลผy przeprowadzaฤ‡ zabiegu defibrylacji symulatora bez zaล‚oลผonej skรณry korpusu.

Zagroลผenia mechaniczne i elektryczne Nie naleลผy uลผywaฤ‡ symulatora SimJunior, jeล›li:

โ€“ koล„czyny nie sฤ… podล‚ฤ…czone do tuล‚owia, โ€“ powล‚oki skรณrne sฤ… rozerwane lub nieprawidล‚owo zamocowane, โ€“ przewody wewnฤ™trzne lub zewnฤ™trzne, rurki lub zล‚ฤ…cza zostaล‚y

uszkodzone, โ€“ wewnฤ…trz lub na zewnฤ…trz symulatora widoczny jest wyciek pล‚ynu, โ€“ sล‚yszalne sฤ… nietypowe dลบwiฤ™ki wskazujฤ…ce na wyciek powietrza

lub uszkodzenie mechaniczne, โ€“ moลผna zaobserwowaฤ‡ oznaki nieprawidล‚owego dziaล‚ania

elementรณw elektrycznych, np. nietypowy zapach, dym lub brak reakcji symulatora.

Ostrzeลผenie:

โ€“ Naleลผy unikaฤ‡ ryzyka ล›ciล›niฤ™cia โ€“ Nie naleลผy uลผywaฤ‡ symulatora bez skรณry zewnฤ™trznej

Uลผytkowanie akumulatora i czynnoล›ci konserwacyjne โ€“ Naleลผy zawsze uลผywaฤ‡ akumulatorรณw zatwierdzonych do uลผytku

z symulatorem SimJunior i urzฤ…dzeniami Link Box oraz SimPad. โ€“ Naleลผy upewniฤ‡ siฤ™, ลผe akumulatory sฤ… prawidล‚owo zainstalowane.

Nieprawidล‚owy montaลผ i podล‚ฤ…czenie akumulatorรณw moลผe spowodowaฤ‡ zwarcie.

Ostrzeลผenia:

โ€“ Akumulatory naleลผy utylizowaฤ‡ zgodnie z lokalnymi przepisami. โ€“ Zewnฤ™trznej ล‚adowarki moลผna uลผywaฤ‡ wyล‚ฤ…cznie w pomieszczeniach

zamkniฤ™tych. โ€“ Akumulator symulatora moลผna ล‚adowaฤ‡ wyล‚ฤ…cznie w temperaturze

0ยฐCโ€“40ยฐC. โ€“ Akumulatorรณw nie wolno uลผywaฤ‡ w sposรณb niedozwolony,

demontowaฤ‡ ani podejmowaฤ‡ prรณb ich naprawy. Nie naleลผy uลผywaฤ‡ akumulatorรณw, ktรณre noszฤ… widoczne ล›lady uszkodzenia, dziaล‚ajฤ… nieprawidล‚owo lub sprawiajฤ… wraลผenie nieszczelnych.

โ€“ Naleลผy zwrรณciฤ‡ szczegรณlnฤ… uwagฤ™ na to, aby nie dotykaฤ‡ bezpoล›rednio elementรณw elektrycznych, gorฤ…cych lub emitujฤ…cych dym. W przypadku wycieku z akumulatora naleลผy go odล‚ฤ…czyฤ‡ i wyjฤ…ฤ‡ z urzฤ…dzenia, gdy tylko takฤ… czynnoล›ฤ‡ bฤ™dzie moลผna bezpiecznie wykonaฤ‡.

โ€“ Kontakt z pล‚ynami niesie zagroลผenie wybuchem. โ€“ Co 30 cykli ล‚adowania naleลผy caล‚kowicie rozล‚adowaฤ‡ akumulator

przed ponownym ล‚adowaniem. Aby rozล‚adowaฤ‡ akumulator, naleลผy uruchomiฤ‡ symulator w trybie zasilania z akumulatora i pozostawiฤ‡ go do automatycznego wyล‚ฤ…czenia.

โ€“ Zuลผyty akumulator moลผna zastฤ…piฤ‡ wyล‚ฤ…cznie akumulatorem przeznaczonym do uลผytku wraz z symulatorem Laerdal SimJunior.

Przechowywanie i transport โ€“ Caล‚kowicie naล‚adowanych akumulatorรณw nie wolno przechowywaฤ‡

przez okres dล‚uลผszy niลผ jeden miesiฤ…c. โ€“ Podczas transportu lotniczego akumulator moลผe znajdowaฤ‡ siฤ™

w symulatorze. โ€“ W przypadku transportu zapasowych akumulatorรณw naleลผy

skontaktowaฤ‡ siฤ™ z liniami lotniczymi lub firmฤ… przewozowฤ… w celu uzyskania informacji dotyczฤ…cych obowiฤ…zujฤ…cych przepisรณw zwiฤ…zanych z transportem.

Ostrzeลผenie:

โ€“ Symulator SimJunior wraz z akcesoriami i torbฤ… transportowฤ… sฤ… ciฤ™ลผkie. Naleลผy zawsze odpowiednio zabezpieczyฤ‡ symulator SimJunior podczas transportu i przechowywania w celu unikniฤ™cia obraลผeล„ ciaล‚a lub uszkodzenia produktu.

Page 161: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

C

zynn

oล›ci

ko

nser

wac

yjne

C

zฤ™ล›c

i zam

ienn

e i a

kces

oria

Spec

yfika

cje

W

stฤ™p

Ro

zwiฤ…

zyw

anie

pr

oble

mรณw

159

Noga z dostฤ™pem ล›rรณdkostnym

Port dostฤ™pu ล›rรณdkostnego do napeล‚niania nogi

Symulator SimJunior

Zล‚ฤ…cze do EKG prawego ramienia

Mostkowa pล‚ytka do defibrylacji

Ramiฤ™ z dostฤ™pem doลผylnym

Zล‚ฤ…cze do EKG prawej nogi

Przewรณd zasilacza

Zewnฤ™trzne zล‚ฤ…cze powietrzne

Przewรณd do symulatora (60โ€“pinowy)

Wstฤ™p

Zล‚ฤ…cze do EKG lewego ramienia

Ramiฤ™ do pomiaru ciล›nienia krwi

Koniuszkowa pล‚ytka do defibrylacji

Zล‚ฤ…cze do EKG lewej nogi

Page 162: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

160

Wstฤ™p

Symulator SimJunior Symulator SimJunior umoลผliwia prowadzenie interaktywnego symulacji w zakresie umiejฤ™tnoล›ci ratujฤ…cych ลผycie. System reaguje na stosowane interwencje kliniczne i informacje wprowadzane z poziomu jednostki sterujฤ…cej instruktora i/lub zachowuje siฤ™ zgodnie z uprzednio zaprogramowanymi scenariuszami, co umoลผliwia skuteczne ฤ‡wiczenie diagnostyki i leczenia pacjenta.

Symulator SimJunior jest wyposaลผony w funkcje symulowania spontanicznej akcji oddechowej, umoลผliwia ฤ‡wiczenie procedur udraลผniania i utrzymywania droลผnoล›ci drรณg oddechowych, emituje gล‚os i dลบwiฤ™ki, umoลผliwia monitorowanie EKG, a takลผe symuluje inne parametry kliniczne, dziฤ™ki czemu jest w peล‚ni funkcjonalnym symulatorem pacjenta pediatrycznego. Symulator SimJunior umoลผliwia obserwacjฤ™ i monitorowanie wiฤ™kszoล›ci parametrรณw ลผyciowych, dziฤ™ki czemu instruktor moลผe oceniฤ‡ umiejฤ™tnoล›ci uczestnikรณw symulacji w realistycznych sytuacjach klinicznych.

Funkcje symulatora SimJunior

โ€“ Realistycznie wykonane drogi oddechowe symulujฤ… rzeczywiste trudnoล›ci z utrzymaniem droลผnoล›ci drรณg oddechowych oraz umoลผliwiajฤ… ฤ‡wiczenie intubacji ustnej i nosowej

โ€“ Widoczna czynnoล›ฤ‡ oddechowa โ€“ Funkcje kardiologiczne, w tym defibrylacja i kardiowersja โ€“ Oczy z wymiennymi ลบrenicami (prawidล‚owe, rozszerzone lub zwฤ™ลผone) โ€“ Konwulsje symulujฤ…ce napady drgawkowe โ€“ Uciล›niฤ™cia klatki piersiowej โ€“ Dostฤ™p naczyniowy โ€“ Prawidล‚owe i nieprawidล‚owe tony serca, szmery oddechowe oraz

odgล‚osy z ukล‚adu pokarmowego

โ€“ Automatyczne sterowanie symulacjฤ… wedล‚ug uprzednio zaprogramowanego i zweryfikowanego scenariusza klinicznego

Moลผliwoล›ฤ‡ autonomicznego uruchamiania symulacji przy uลผyciu scenariuszy na urzฤ…dzeniu SimPad lub w aplikacji LLEAP (na komputerze). Przebieg stanu pacjenta jest wstฤ™pnie zaprogramowany, a symulator automatycznie reaguje na interwencje kliniczne przeprowadzone przez uczestnika symulacji.

Wymiary caล‚kowite

Dล‚ugoล›ฤ‡/szerokoล›ฤ‡ (sam symulator): 120 cm x 42,5  cm Waga (sam symulator): 11,36 kg

Ubranie symulatora SimJunior

SimJunior jest dostarczany wraz z odpowiednio przystosowanym ubraniem zapinanym na rzepy, co uล‚atwia jego zdejmowanie. Instrukcje dotyczฤ…ce prania ubraล„ znajdujฤ… siฤ™ na metkach. โ€“ Koszula โ€“ Krรณtkie spodenki โ€“ Bokserki

Ogรณlne funkcje kliniczne Funkcje drรณg oddechowych

Drogi oddechowe sฤ… anatomicznie prawidล‚owe do tchawicy. Na drogach oddechowych moลผna wykonywaฤ‡ nastฤ™pujฤ…ce zabiegi: โ€“ odchylenie gล‚owy/uniesienie podbrรณdka, โ€“ odciฤ…gniฤ™cie ลผuchwy z jej wyluksowaniem โ€“ ucisk i manipulacja chrzฤ…stkฤ… pierล›cieniowatฤ…, โ€“ odsysanie (ustne i nosowo-gardล‚owe).

Symulator poddaje siฤ™ wentylacji nastฤ™pujฤ…cymi metodami standardowymi i ratunkowymi: โ€“ wentylacja przy pomocy worka samorozprฤ™ลผalnego, โ€“ intubacja ustno-tchawicza, โ€“ intubacja nosowo-tchawicza.

Przed uลผyciem instrumentรณw wprowadzanych do drรณg oddechowych naleลผy nawilลผyฤ‡ je lubrykantem do drรณg oddechowych dostarczonym przez firmฤ™ Laerdal.

W celu zabezpieczenia droลผnoล›ci drรณg oddechowych symulatora moลผna stosowaฤ‡ nastฤ™pujฤ…ce urzฤ…dzenia i metody: โ€“ maska krtaniowa (rozmiar nr 2,5), โ€“ rurka dotchawicza (ล›rednica wewnฤ™trzna 4,5 z mankietem, 5,5 bez

mankietu).

Zaleca siฤ™ stosowanie giฤ™tkniego mandrynu. Mandryn nie moลผe wychodziฤ‡ z drugiej strony rurki dotchawiczej.

O niewล‚aล›ciwym wprowadzeniu rurki ล›wiadczy wystฤ…pienie okolicznoล›ci wymienionych poniลผej: โ€“ Intubacja do prawego odgaล‚ฤ™zienia โ€“ jednostronne unoszenie siฤ™

klatki piersiowej โ€“ Rozdฤ™cie ลผoล‚ฤ…dka โ€“ Brak szmerรณw oddechowych (patrz sekcja poล›wiฤ™cona

oddychaniu)

Funkcje symulatora moลผna tak skonfigurowaฤ‡, aby symulowaล‚y rรณลผne scenariusze droลผnoล›ci drรณg oddechowych: โ€“ Obrzฤ™k jฤ™zyka โ€“ prawidล‚owy, poล›redni, maksymalny โ€“ Pล‚uca otwarte/zamkniฤ™te

Akcja oddechowa

Przy uลผyciu symulatora SimJunior moลผna symulowaฤ‡ oddech spontaniczny z widocznym unoszeniem siฤ™ i opadaniem klatki piersiowej oraz zmiennฤ… czฤ™stoล›ciฤ… oddechรณw. Oddychanie jest generowane przez sprฤ™ลผarkฤ™ powietrza znajdujฤ…cฤ… siฤ™ w prawym udzie symulatora. โ€“ Obustronne wznoszenie siฤ™ i opadanie klatki piersiowej podczas

oddychania spontanicznego

โ€“ Jednostronne wznoszenie siฤ™ i opadanie klatki piersiowej w przypadku intubacji do prawego odgaล‚ฤ™zienia podczas wentylacji

โ€“ Jednostronne i dwustronne szmery pล‚ucne โ€“ Prawidล‚owe i nieprawidล‚owe szmery oddechowe โ€“ Zmienna czฤ™stoล›ฤ‡ oddechu (0โ€“60 oddechรณw na minutฤ™) โ€“ Miejsca osล‚uchiwania z przodu (4)

Lewe i prawe pล‚uco moลผna zamknฤ…ฤ‡ niezaleลผnie od siebie lub rรณwnoczeล›nie w celu wytworzenia czฤ™ล›ciowej lub caล‚kowitej niedroลผnoล›ci drรณg oddechowych. Symulator SimJunior umoลผliwia rรณwnieลผ prowadzenie wentylacji wspomaganej.

Uwaga: pล‚uca symulatora nie sฤ… przystosowane do uลผycia zastawki PEEP.

Page 163: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

C

zynn

oล›ci

ko

nser

wac

yjne

C

zฤ™ล›c

i zam

ienn

e i a

kces

oria

Spec

yfika

cje

W

stฤ™p

Ro

zwiฤ…

zyw

anie

pr

oble

mรณw

161

Wstฤ™p

Funkcje krฤ…ลผenia

Serce: โ€“ Obszerna biblioteka EKG, tฤ™tna w zakresie 0โ€“200โ€“ Tony serca โ€“ poล‚oลผenie przednie (1) โ€“ Monitorowanie rytmu EKG (4 zล‚ฤ…cza, 3 odprowadzenia EKG) โ€“ Wyล›wietlanie 12-odprowadzeniowego EKG (tylko przy uลผyciu

aplikacji LLEAP) โ€“ Tryb stymulacji โ€“ Defibrylacja i kardiowersja z zastosowaniem rzeczywistych

defibrylatorรณw

Defibrylacja: โ€“ Liczba wyล‚adowaล„ niezbฤ™dna do automatycznej konwersji jest

ustawiana osobno dla kaลผdej symulacji przypadku pacjenta

Piny do defibrylacji:

Piny do 3-odprowadzeniowego EKG:

Ciล›nienie krwi i tฤ™tno: โ€“ Ciล›nienie krwi mierzone rฤ™cznie poprzez osล‚uchiwanie wedล‚ug

metody Korotkowa โ€“ Dwustronne tฤ™tno na tฤ™tnicy szyjnej โ€“ Tฤ™tno centralne moลผna ustawiฤ‡ jako prawidล‚owe, sล‚abe/nitkowate

lub nieobecne โ€“ Tฤ™tno promieniowe i ramienne moลผna ustawiฤ‡ jako prawidล‚owe,

sล‚abe/nitkowate lub nieobecne โ€“ Tฤ™tno na tฤ™tnicy szyjnej, ramiennej i promieniowej

zsynchronizowane z EKG โ€“ Siล‚a tฤ™tna zmienna wraz z ciล›nieniem krwiโ€“ Urzฤ…dzenie wykrywa i rejestruje palpacyjne badanie tฤ™tna

Funkcje resuscytacji krฤ…ลผeniowo-oddechowej (RKO)

โ€“ Zgodne z wytycznymi na rok 2010

โ€“ Uciล›niฤ™cia generujฤ… wyczuwalne tฤ™tno, wykres pomiarรณw ciล›nienia krwi i artefakty EKG

โ€“ Realistyczna gล‚ฤ™bokoล›ฤ‡ uciskania i opรณr โ€“ Wykrywanie gล‚ฤ™bokoล›ci i tempa uciskรณw

Funkcje naczyniowe

Dostฤ™p doลผylny:

Dostฤ™p doลผylny jest moลผliwy na prawym ramieniu i dล‚oni. Ramiฤ™ z  dostฤ™pem doลผylnym moลผna skonfigurowaฤ‡ do pracy w trybach wkล‚ucia doลผylnego, wlewu oraz bolusa do: โ€“ ลผyล‚ obwodowych przedramienia, โ€“ doล‚u przedล‚okciowego i grzbietu dล‚oni.

Dostฤ™p ล›rรณdkostny:

Moลผliwoล›ฤ‡ dostฤ™pu do wlewu ล›rรณdkostnego: โ€“ guzowatoล›ฤ‡ piszczeli (prawa noga), โ€“ kostka przyล›rodkowa.

Uwaga: symulator SimJunior nie zostaล‚ wyposaลผony w punkty do podawania iniekcji domiฤ™ล›niowych. Nie wolno podawaฤ‡ iniekcji domiฤ™ล›niowych.

Ustawienia dลบwiฤ™kรณw symulatora SimJunior Symulator SimJunior moลผna osล‚uchiwaฤ‡ w rรณลผnych miejscach w celu monitorowania i wykrywania tonรณw serca, szmerรณw pล‚uc, odgล‚osรณw ลผoล‚ฤ…dka i jelit. Symulator SimJunior obsล‚uguje rรณwnieลผ funkcjฤ™ programowania gล‚osu.

Wiฤ™cej informacji na temat ustawiania dลบwiฤ™kรณw symulatora SimJunior znajduje siฤ™ w instrukcji uลผytkowania urzฤ…dzenia SimPad lub plikach pomocy aplikacji LLEAP.

Page 164: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

162

Oprogramowanie do symulacji

Komputer instruktora

Komputer instruktora zarzฤ…dza sesjami symulacji za pomocฤ… programu LLEAP. Do programu LLEAP, a takลผe innych aplikacji stosowanych podczas symulacji, moลผna uzyskaฤ‡ dostฤ™p z poziomu Laerdal Simulation Home.

Licencja oprogramowania Komputer instruktora jest wysyล‚any z firmy Laerdal Medical wraz ze wstฤ™pnie aktywowanฤ… licencjฤ… na zainstalowane oprogramowanie LLEAP.

Zmiany lub aktualizacja elementรณw sprzฤ™towych komputera (np.  wymiana twardego dysku lub pล‚yty gล‚รณwnej) mogฤ… skutkowaฤ‡ wygaล›niฤ™ciem licencji. Naleลผy skontaktowaฤ‡ siฤ™ z regionalnym przedstawicielem Laerdal w celu uzyskania pomocy w zakresie ponownej aktywacji licencji.

Laerdal Simulation HomeLaerdal Simulation Home to aplikacja, za pomocฤ… ktรณrej moลผna wyszukaฤ‡ i uruchomiฤ‡ program LLEAP oraz inne programy firmy Laerdal zwiฤ…zane z symulacjฤ… pacjenta. Z jej poziomu moลผna takลผe otworzyฤ‡ pliki pomocy. Aplikacja Laerdal Simulation Home znajduje siฤ™ w folderze Laerdal Medical w menu start systemu Windows (Windows 7).

Oprogramowanie stosowane podczas sesji symulacji skล‚ada siฤ™ z nastฤ™pujฤ…cych gล‚รณwnych aplikacji:

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server i Session Viewer

Ponadto do projektowania i przygotowania symulacji wykorzystuje siฤ™ program SimDesigner i inne aplikacje.

LLEAPLLEAP (Leardal Learning Application) to aplikacja obsล‚ugiwana przez instruktora, sล‚uลผฤ…ca do uruchamiania, sterowania i monitorowania sesji symulacji. Program LLEAP moลผe byฤ‡ obsล‚ugiwany w trybie automatycznym lub rฤ™cznym. Tryb automatyczny stosowany jest w przypadku scenariuszy wstฤ™pnie zaprogramowanych, zaล› tryb rฤ™czny umoลผliwia instruktorowi peล‚nฤ… rฤ™cznฤ… kontrolฤ™ nad przebiegiem sesji. Prowadzenie symulacji z wykorzystaniem trybu rฤ™cznego wymaga fachowej wiedzy medycznej, pozwalajฤ…cej zbudowaฤ‡ klinicznie realistyczne symulacje.

Voice Conference Application (VCA)Oprogramowanie VCA odpowiada za przesyล‚anie wszystkich odgล‚osรณw wykorzystywanych podczas symulacji. Umoลผliwia instruktorowi komunikacjฤ™ za poล›rednictwem symulatora w trakcie sesji. VCA moลผe sล‚uลผyฤ‡ takลผe do porozumiewania siฤ™ z pozostaล‚ymi instruktorami w sieci i tworzenia odrฤ™bnych kanaล‚รณw, za poล›rednictwem ktรณrych porozumiewaฤ‡ siฤ™ bฤ™dฤ… mogli wyล‚ฤ…cznie czล‚onkowie zespoล‚u.

Patient MonitorPatient Monitor to aplikacja emulujฤ…ca typowy szpitalny monitor pacjenta. Stanowi konsolฤ™ uczestnika symulacji. Zarรณwno instruktor, jak i uczestnicy symulacji mogฤ… jฤ… konfigurowaฤ‡ oraz sterowaฤ‡ niฤ… za pomocฤ… menu dotykowego monitora.

Session Viewer i SimView ServerSession Viewer i SimView Server to aplikacje rejestrujฤ…ce w trakcie symulacji materiaล‚y wideo i zrzuty z ekranu monitora pacjenta. Zapewniajฤ… takลผe interfejs umoลผliwiajฤ…cy przeprowadzenie podsumowania sesji. Po zakoล„czeniu sesji program LLEAP generuje pliki dziennika, ktรณre sฤ… nastฤ™pnie przesyล‚ane do aplikacji Session Viewer lub SimView Server i ล‚ฤ…czone z plikami wideo w celu przeprowadzenia podsumowania.

Session Viewer zazwyczaj uruchamiany jest lokalnie na tym samym komputerze, na ktรณrym uruchomiono program LLEAP, zaล› SimView Server na dedykowanym serwerze w sieci lokalnej. Przy pierwszym uruchomieniu programu LLEAP uลผytkownik proszony jest o wybรณr systemu podsumowania spoล›rรณd dostฤ™pnych na komputerze lub w sieci lokalnej. Ustawienie to moลผe zostaฤ‡ pรณลบniej zmienione.

Inne aplikacjePodczas obsล‚ugi sesji symulacji uลผywane sฤ… takลผe inne programy, na  przykล‚ad License Manager do obsล‚ugi licencji programรณw oraz Simulator Firmware & Network Wizard do aktualizacji firmware'u symulatora i rozwiฤ…zywania problemรณw z sieciฤ….

SimDesignerSimDesigner to aplikacja sล‚uลผฤ…ca do konfigurowania wstฤ™pnie zaprogramowanych scenariuszy uลผytkownika. Moลผe byฤ‡ uลผywana takลผe do analizy i wydruku graficznej reprezentacji scenariusza.

Instalacja aplikacji SimDesigner jest wymagana do konwersji starszych plikรณw aplikacji instruktora do formatรณw obsล‚ugiwanych przez program LLEAP.

Pliki pomocy

Wiฤ™cej informacji na temat programu LLEAP i innych aplikacji moลผna znaleลบฤ‡ w plikach pomocy:

1. Kliknij kolejno pozycje <Start> i <Wszystkie programy> w systemie Windows.

2. Wybierz <Laerdal Simulation Home>.

3. Wybierz <Pomoc>.

Do pobrania z internetuNajnowszy Podrฤ™cznik uลผytkownika oraz oprogramowanie moลผna pobraฤ‡ ze strony: www.laerdal.com/downloads.

Page 165: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

163

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

C

zynn

oล›ci

ko

nser

wac

yjne

C

zฤ™ล›c

i zam

ienn

e i a

kces

oria

Spec

yfika

cje

W

stฤ™p

Ro

zwiฤ…

zyw

anie

pr

oble

mรณw

Konfiguracja symulatora

Przygotowanie do symulacji Po przygotowaniu symulatora SimJunior oraz skonfigurowaniu wszystkich jednostek interaktywnych (SimPad lub komputer instruktora i monitor pacjenta) i przygotowaniu ich do uลผycia naleลผy przeprowadziฤ‡ koล„cowe przygotowania przed wล‚ฤ…czeniem symulatora SimJunior i przeprowadzeniem symulacji.

Koล„cowe przygotowania do symulacji obejmujฤ… nastฤ™pujฤ…ce czynnoล›ci:

โ€ข przygotowanie koล„czyny dolnej z dostฤ™pem ล›rรณdkostnym,

โ€ข podanie pล‚ynรณw we wlewie doลผylnym,

โ€ข odprowadzenie nadmiaru pล‚ynu podawanego doลผylnie,

โ€ข czyszczenie ramienia z dostฤ™pem doลผylnym,

โ€ข podล‚ฤ…czenie pล‚ytek ze zล‚ฤ…czami defibrylatora,

โ€ข podล‚ฤ…czanie mankietu do pomiaru ciล›nienia krwi,

โ€ข wymiana ลบrenic,

โ€ข podล‚ฤ…czenie sprฤ™ลผarki zewnฤ™trznej,

โ€ข zmiana ustawieล„ sprฤ™ลผarki wewnฤ™trznej.

Przygotowanie koล„czyny dolnej z dostฤ™pem ล›rรณdkostnym Prawa koล„czyna dolna symulatora jest przeznaczona do wlewu ล›rรณdkostnego. W prawej nodze odwzorowano anatomiฤ™ kolana, piszczeli, guzowatoล›ci piszczeli i kostki przyล›rodkowej. Prawa noga jest wyposaลผona w rurki do wlewu doลผylnego oraz jeden worek kroplรณwkowy peล‚niฤ…cy funkcjฤ™ zbiornika podczas wlewu.

Dodatkowe wymagania sprzฤ™towe:

โ€ข worek kroplรณwkowy oraz zestaw do podawania wlewu doลผylnego,

โ€ข koncentrat pล‚ynu imitujฤ…cego krew

โ€ข strzykawka o pojemnoล›ci 35 ml i igล‚a do wkล‚ucia ล›rรณdkostnego o rozmiarze 16 G

Aby wypeล‚niฤ‡ koล„czynฤ™ dolnฤ… z dostฤ™pem ล›rรณdkostnym i przygotowaฤ‡ jฤ… do uลผycia, naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci:

1. Unieล›ฤ‡ nogฤ™ pionowo,

2. Otworzyฤ‡ korek w piฤ™cie. 3. Przy uลผyciu strzykawki napeล‚niฤ‡ koล›ฤ‡ pล‚ynem symulujฤ…cym krew

w objฤ™toล›ci 240โ€“250 ml.4. Zamocowaฤ‡ rurki podล‚ฤ…czone do worka kroplรณwkowego.

(Przy uลผyciu regulatora obrotowego otworzyฤ‡ lub zamknฤ…ฤ‡ przewรณd w zaleลผnoล›ci od potrzeb, aby zniwelowaฤ‡ nadmierne ciล›nienie).

5. Zamknฤ…ฤ‡ rurkฤ™ biegnฤ…cฤ… do zbiornika, tak aby pล‚yn imitujฤ…cy krew pozostaล‚ w koล›ci w celu umoลผliwienia jego aspiracji.

6. Po wypeล‚nieniu worka zatrzymaฤ‡ wlew i wymieniฤ‡ worek na pusty.

Przed dล‚ugotrwaล‚ym przechowywaniem symulatora naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci: โ€“ odล‚ฤ…czyฤ‡ przewรณd do wlewu doลผylnego oraz zbiornik od stopy, โ€“ umoลผliwiฤ‡ peล‚ny drenaลผ pล‚ynu, โ€“ wysuszyฤ‡ nogฤ™ na powietrzu, bez zaล‚oลผonego korka.

Uwaga: nie stosowaฤ‡ fizjologicznego roztworu soli. Moลผe to przyczyniฤ‡ siฤ™ do szybszego zuลผycia nogi. W celu unikniฤ™cia odkล‚adania siฤ™ kamienia naleลผy stosowaฤ‡ wodฤ™ destylowanฤ… lub dejonizowanฤ….

Podanie pล‚ynรณw we wlewie doลผylnym Prawe ramiฤ™ z dostฤ™pem doลผylnym umoลผliwia prowadzenie symulacji w zakresie podawania lekรณw we wlewie doลผylnym, wprowadzania instrumentรณw przez dostฤ™p doลผylny, wlewรณw oraz bolusa do naczyล„ obwodowych przedramienia, doล‚u przedล‚okciowego oraz grzbietu dล‚oni.

Do symulacji poล›wiฤ™conych wlewom doลผylnym naleลผy stosowaฤ‡ igล‚y o rozmiarze od 20 do 22 G. Aby zapobiec zatkaniu siฤ™ ukล‚adu dostฤ™pu doลผylnego, do symulacji podawania lekรณw drogฤ… doลผylnฤ… naleลผy stosowaฤ‡ wyล‚ฤ…cznie wodฤ™ destylowanฤ… lub dejonizowanฤ….

Page 166: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

164

Konfiguracja symulatora

Odprowadzenie nadmiaru pล‚ynu podawanego doลผylnie Ukล‚ad doลผylnego podawania pล‚ynรณw jest ukล‚adem otwartym. Pล‚yny podawane doลผylnie sฤ… odprowadzane w trakcie ich podawania.

Przed kaลผdฤ… sesjฤ…: 1. Podล‚ฤ…czyฤ‡ rurkฤ™ przelewowฤ… dostฤ™pu doลผylnego (prawe ramiฤ™

symulatora) do zbiornika nadmiarowego (np. worek kroplรณwkowy). 2. Podczas symulacji nadmiar pล‚ynu powinien byฤ‡ odprowadzany do

zbiornika.

Czyszczenie ramienia z dostฤ™pem doลผylnym Ramiฤ™ z dostฤ™pem doลผylnym naleลผy oczyล›ciฤ‡ po kaลผdej sesji lub pod koniec kaลผdego dnia uลผycia, przepล‚ukujฤ…c je roztworem 60% izopropanolu lub 70% etanolu.

Instalacja pล‚ytek ze zล‚ฤ…czami defibrylatora Korpus symulatora wyposaลผono w dwa zล‚ฤ…cza do przewodรณw defibrylatora. Przed przystฤ…pieniem do defibrylacji naleลผy odkrฤ™ciฤ‡ i zdjฤ…ฤ‡ piny do defibrylacji.

Do zestawu symulatora doล‚ฤ…czone sฤ… dwie pล‚ytki ze zล‚ฤ…czami defibrylatora. Pล‚ytki ze zล‚ฤ…czami defibrylatora naleลผy zaล‚oลผyฤ‡ przed uลผyciem defibrylatora ล‚yลผkowego pod napiฤ™ciem. Naleลผy mocno przykrฤ™ciฤ‡ pล‚ytki zล‚ฤ…czy.

Podczas defibrylacji Wraz z symulatorem SimJunior moลผna stosowaฤ‡ standardowy defibrylator (niedoล‚ฤ…czony). Podczas przeprowadzania zabiegu defibrylacji z uลผyciem symulatora i prawdziwego defibrylatora istnieje ryzyko poraลผenia prฤ…dem. Naleลผy zachowaฤ‡ wszystkie standardowe ล›rodki bezpieczeล„stwa podczas stosowania defibrylatora na symulatorze.

Przestroga: podczas defibrylacji symulator nie moลผe stykaฤ‡ siฤ™ z powierzchniami lub przedmiotami przewodzฤ…cymi prฤ…d.

Ostrzeลผenia:

โ€“ Zabieg defibrylacji moลผna prowadziฤ‡ wyล‚ฤ…cznie przez zล‚ฤ…cza do defibrylacji.

โ€“ Nie naleลผy przeprowadzaฤ‡ zabiegu defibrylacji symulatora bez zaล‚oลผonej skรณry korpusu.

Podล‚ฤ…czanie mankietu do pomiaru ciล›nienia krwi

Symulator jest dostarczany z odpowiednio przystosowanym mankietem do pomiaru ciล›nienia krwi. Przed uลผyciem mankietu naleลผy podล‚ฤ…czyฤ‡ rurkฤ™ do biaล‚ego zล‚ฤ…cza ciล›nienia krwi z tyล‚u urzฤ…dzenia Link Box.

Uwaga: gล‚oล›nik generujฤ…cy odgล‚osy ciล›nienia krwi umieszczony jest w lewym dole przedล‚okciowym, zaznaczonym kรณล‚kiem na poniลผszej ilustracji. Tฤ™tno z tฤ™tnicy promieniowej i ramiennej moลผna zmierzyฤ‡ w obszarach oznaczonych prostokฤ…tami.

Kalibracja mankietu do pomiaru ciล›nienia krwi w LLEAP

1. W menu wybraฤ‡ opcjฤ™ <Narzฤ™dzia>.

2. W menu narzฤ™dzi wybraฤ‡ polecenie <Ustawienia Symulatora.

3. W podmenu wybraฤ‡ polecenie <Kalibruj ciล›nienie krwi>.

4. Postฤ™powaฤ‡ zgodnie z poleceniami kreatora wyล›wietlanymi na ekranie w celu przeprowadzenia kalibracji.

Kalibracja mankietu do pomiaru ciล›nienia krwi w SimPad

1. W menu wybraฤ‡ opcjฤ™ <Kalibracja>.

2. W menu rozwijanym wybraฤ‡ polecenie <Kalibruj ciล›nienie krwi>.

3. Postฤ™powaฤ‡ zgodnie z poleceniami kreatora wyล›wietlanymi na ekranie w celu przeprowadzenia kalibracji.

Page 167: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

165

Opr

ogra

mow

anie

do

 sym

ulac

ji

SKon

figur

acja

sym

ulat

ora

Czy

nnoล›

ci

kons

erw

acyj

ne

Czฤ™

ล›ci z

amie

nne

i akc

esor

iaSp

ecyfi

kacj

e

Wst

ฤ™p

Rozw

iฤ…zy

wan

ie

prob

lem

รณw

Konfiguracja symulatora

Wymiana ลบrenic.

Symulator SimJunior dostarczany jest z normalnymi ลบrenicami zaล‚oลผonymi na gaล‚ki oczne. Do zestawu SimJunior doล‚ฤ…czono osobny zestaw, w ktรณrego skล‚ad wchodzฤ… plastikowe wkล‚adki ลบrenic (zwฤ™ลผone i rozszerzone).

Wymiana ลบrenic:

1. Delikatnie rozszerzyฤ‡ powieki, uwaลผajฤ…c, aby nie rozerwaฤ‡ skรณry na twarzy symulatora.

2. Za pomocฤ… ssawki znajdujฤ…cej siฤ™ w zestawie lub paznokcia delikatnie zdjฤ…ฤ‡ ลบrenicฤ™ z gaล‚ki ocznej.

3. Zastฤ…piฤ‡ ลบrenicฤ™ odpowiedniฤ… wkล‚adkฤ…, zakล‚adajฤ…c jฤ… przy uลผyciu ssawki lub wciskajฤ…c jฤ… delikatnie na miejsce.

Uลผywanie sprฤ™ลผarki zewnฤ™trznej Sprฤ™ลผarkฤ™ zewnฤ™trznฤ… naleลผy podล‚ฤ…czyฤ‡ do przezroczystej rurki znajdujฤ…cej siฤ™ w wiฤ…zce przewodรณw wychodzฤ…cych po prawej stronie symulatora. W przypadku stosowania zewnฤ™trznej sprฤ™ลผarki moลผna wyล‚ฤ…czyฤ‡ sprฤ™ลผarkฤ™ wewnฤ™trznฤ… z poziomu urzฤ…dzenia SimPad lub urzฤ…dzenia LLEAP

Dodatkowe informacje na temat sprฤ™ลผarek zewnฤ™trznych oraz paneli regulacyjnych zgodnych z symulatorem SimJunior moลผna uzyskaฤ‡ od przedstawiciela firmy Laerdal.

Wล‚ฤ…czanie lub wyล‚ฤ…czanie sprฤ™ลผarki wewnฤ™trznej z poziomu urzฤ…dzenia SimPad

1. Wybraฤ‡ polecenie <Tryb rฤ™czny>, wybraฤ‡ wyglฤ…d ekranu i rozpoczฤ…ฤ‡ sesjฤ™.

2. W dolnym menu wybraฤ‡ opcjฤ™ <Rรณลผne>.

3. W podmenu wybraฤ‡ polecenie <Sprฤ™ลผarka>.

4. Wprowadziฤ‡ wล‚aล›ciwe zmiany w oknie dialogowym i kliknฤ…ฤ‡ OK.

Wล‚ฤ…czanie lub wyล‚ฤ…czanie sprฤ™ลผarki wewnฤ™trznej z poziomu aplikacji LLEAP

1. W menu wybraฤ‡ opcjฤ™ <Narzฤ™dzia>.

2. W menu narzฤ™dzi wybraฤ‡ polecenie <Ustawienie Symulatora>.

3. W podmenu wybraฤ‡ polecenie <Sprฤ™ลผarka wewnฤ™trzna>.

4. Wprowadziฤ‡ wล‚aล›ciwe zmiany w oknie dialogowym i kliknฤ…ฤ‡ OK.

Page 168: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

166

Uwaga: Informacje dotyczฤ…ce czฤ™ล›ci zamiennych znajdujฤ… siฤ™ w sekcji: Czฤ™ล›ci zamienne i akcesoria.

Przed dล‚uลผszym przechowywaniem lub wysyล‚kฤ… naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci:

โ€“ przepล‚ukaฤ‡ ramiฤ™ z dostฤ™pem doลผylnym roztworem 60% izopropanolu lub 70% etanolu, otworzyฤ‡ zawรณr spustowy na koล„cรณwce piฤ™ty prawej nogi symulatora.

Czynnoล›ci konserwacyjne

Czynnoล›ci obsล‚ugowe po kaลผdej sesji symulacji W celu zapewnienia jak najdล‚uลผszego czasu eksploatacji symulatora SimJunior naleลผy stosowaฤ‡ nastฤ™pujฤ…ce ล›rodki obsล‚ugi zapobiegawczej:

โ€“ wyล‚ฤ…czyฤ‡ urzฤ…dzenia SimPad i LinkBox oraz komputery,

โ€“ w razie potrzeby naล‚adowaฤ‡ akumulatory,

โ€“ przepล‚ukaฤ‡ ukล‚ad ramienia z dostฤ™pem doลผylnym oraz przeprowadziฤ‡ drenaลผ nogi z dostฤ™pem ล›rรณdkostnym (korek w koล„cรณwce nogi zostawiฤ‡ otwarty),

โ€“ po kaลผdej sesji, w czasie ktรณrej uลผywane byล‚o ramiฤ™ z dostฤ™pem doลผylnym, naleลผy je wypล‚ukaฤ‡ roztworem 60% izopropanolu lub 70% etanolu,

โ€“ wytrzeฤ‡ skรณrฤ™ wilgotnฤ… ล›ciereczkฤ…,

โ€“ zdjฤ…ฤ‡ mokre ubrania lub bieliznฤ™,

โ€“ usunฤ…ฤ‡ pozostaล‚oล›ci plastrรณw mokrฤ… ล›ciereczkฤ… lub alkoholem do dezynfekcji,

โ€“ w zaleลผnoล›ci od stopnia zuลผycia symulatora wymieniฤ‡ zuลผyte lub uszkodzone elementy,

โ€“ wymieniฤ‡ zล‚ฤ…cza i przewody z widocznymi oznakami uszkodzeล„.

โ€“ Czynnoล›ci obsล‚ugowe powinny byฤ‡ regularnie wykonywane przez wykwalifikowany personel

Czynnoล›ci serwisowe naleลผy wykonywaฤ‡ zawsze, gdy:

โ€“ doszล‚o do wycieku pล‚ynu wewnฤ…trz lub na zewnฤ…trz symulatora,

โ€“ symulator byล‚ uลผywany w zapylonym otoczeniu.

Page 169: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

167

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

Czy

nnoล›

ci

kons

erw

acyj

ne

Czฤ™

ล›ci z

amie

nne

i akc

esor

iaSp

ecyfi

kacj

e

Wst

ฤ™p

Rozw

iฤ…zy

wan

ie

prob

lem

รณw

Czynnoล›ci konserwacyjne

Otwieranie korpusu

Korpus symulatora moลผna otwieraฤ‡ w celu przeprowadzenia nastฤ™pujฤ…cych procedur: โ€“ podล‚ฤ…czanie lub wymiana koล„czyn, โ€“ wymiana akumulatora symulatora, โ€“ wymiana worka symulujฤ…cego unoszenie klatki piersiowej i worka

pล‚ucnego, โ€“ wymiana skรณry korpusu, โ€“ przeprowadzenie ogรณlnej kontroli.

Ostrzeลผenie: Korpus naleลผy otwieraฤ‡ od lewej do prawej strony, ostroลผnie odczepiajฤ…c skรณrฤ™. Nie naleลผy ciฤ…gnฤ…ฤ‡ mocno w celu uniesienia skรณry, gdyลผ moลผna w ten sposรณb uszkodziฤ‡ przewody w klatce piersiowej.

1. Odczepiฤ‡ skรณrฤ™ korpusu od uchwytรณw po lewej stronie korpusu i na obu barkach.

Wymiana akumulatora symulatora

1. Otworzyฤ‡ korpus symulatora.

2. Odwinฤ…ฤ‡ skรณrฤ™ korpusu w prawo.

3. Odล‚ฤ…czyฤ‡ przewรณd zล‚ฤ…cza defibrylatora.

4. Przewรณd zล‚ฤ…cza defibrylatora musi byฤ‡ odล‚ฤ…czony po prawej stronie symulatora poniลผej obrysu klatki piersiowej.

Uwaga: NIE WOLNO odล‚ฤ…czaฤ‡ rurek i przewodรณw ล‚ฤ…czฤ…cych piankฤ™ ลผoล‚ฤ…dka z symulatorem.

5. Zaล‚oลผyฤ‡ skรณrฤ™ korpusu, wykonujฤ…c czynnoล›ci 1โ€“4 w odwrotnej kolejnoล›ci.

2. Wysunฤ…ฤ‡ akumulator zza taล›my mocujฤ…cej.

3. Wysunฤ…ฤ‡ do gรณry zล‚ฤ…cze akumulatora z wnฤ™trza symulatora. Rozล‚ฤ…czyฤ‡ zล‚ฤ…cze akumulatora.

4. Wyjฤ…ฤ‡ akumulator z symulatora.

5. Zainstalowaฤ‡ naล‚adowany akumulator lub nowy akumulator zatwierdzony przez firmฤ™ Laerdal do stosowania z symulatorem SimJunior.

6. Podล‚ฤ…czyฤ‡ akumulator do symulatora.

7. Zaล‚oลผyฤ‡ skรณrฤ™ korpusu.

Page 170: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

168

Czynnoล›ci konserwacyjne

ลadowanie akumulatora symulatora

Akumulator symulatora ล‚aduje siฤ™ samoczynnie podczas pracy. Jeล›li zajdzie taka potrzeba, akumulator moลผna naล‚adowaฤ‡ przy pomocy dodatkowej ล‚adowarki zewnฤ™trznej.

1. Wyล‚ฤ…czyฤ‡ zasilanie symulatora za pomocฤ… urzฤ…dzenia Link Box.

2. Wyjฤ…ฤ‡ akumulator z symulatora.

3. Podล‚ฤ…czyฤ‡ odpowiedniฤ… ล‚adowarkฤ™ zewnฤ™trznฤ… (z przewodem zasilajฤ…cym speล‚niajฤ…cym lokalne wymagania) do dolnej czฤ™ล›ci akumulatora. Podล‚ฤ…czyฤ‡ przewรณd zasilajฤ…cy ล‚adowarki do gniazda ล›ciennego.

4. Po zakoล„czeniu ล‚adowania z powrotem zainstalowaฤ‡ akumulator w symulatorze.

Wymiana worka do symulacji unoszenia klatki piersiowej Worek do symulacji unoszenia klatki piersiowej znajduje siฤ™ w dolnej czฤ™ล›ci pล‚yty klatki piersiowej, centralnie pod pล‚ucami.

1. Otworzyฤ‡ skรณrฤ™ korpusu, aby odsล‚oniฤ‡ pล‚ytฤ™ klatki piersiowej. Patrz sekcja Otwieranie korpusu.

2. Odล‚ฤ…czyฤ‡ przezroczystฤ… rurkฤ™ od worka pล‚ucnego i wyjฤ…ฤ‡ worek. W celu uzyskania bardziej szczegรณล‚owych informacji, patrz: Wymiana worka pล‚ucnego

3. Odล‚ฤ…czyฤ‡ przezroczystฤ… rurkฤ™ od worka do symulacji unoszenia klatki piersiowej.

4. Zutylizowaฤ‡ stary worek.

5. Wล‚oลผyฤ‡ nowy worek.

6. Podล‚ฤ…czyฤ‡ rurki do nowego worka.

7. Zamknฤ…ฤ‡ korpus i zaล‚oลผyฤ‡ skรณrฤ™.

Wymiana worka pล‚ucnego Jeล›li dojdzie do wycieku, naleลผy wymieniฤ‡ worek pล‚ucny (w jamie klatki piersiowej).

1. Otworzyฤ‡ skรณrฤ™ korpusu.

2. Odล‚ฤ…czyฤ‡ przezroczyste rurki od spodu kaลผdej strony worka pล‚ucnego. Por. krok 2 na ilustracji w sekcji Wymiana worka symulujฤ…cego unoszenie klatki piersiowej.

3. Odล‚ฤ…czyฤ‡ gรณrny ล›rodkowy zacisk worka pล‚ucnego.

4. Wyjฤ…ฤ‡ worek z gniazda, ล‚agodnie ciฤ…gnฤ…c za jego ล›rodkowฤ… i gรณrnฤ… czฤ™ล›ฤ‡.

5. Aby zainstalowaฤ‡ nowy worek pล‚ucny, naleลผy wykonaฤ‡ wymienione czynnoล›ci w odwrotnej kolejnoล›ci.

Page 171: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

169

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

Czy

nnoล›

ci

kons

erw

acyj

ne

Czฤ™

ล›ci z

amie

nne

i akc

esor

iaSp

ecyfi

kacj

e

Wst

ฤ™p

Rozw

iฤ…zy

wan

ie

prob

lem

รณw

Wymiana powล‚ok skรณrnych symulatora W przypadku rozerwania, przedziurawienia lub poplamienia skรณry symulatora naleลผy jฤ… wymieniฤ‡.

Skรณra korpusu:

Wymiana skรณry korpusu symulatora: patrz sekcja โ€žOtwieranie korpusuโ€.

Skรณra ramienia:

Aby wymieniฤ‡ skรณrฤ™ ramienia symulatora, naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci:

1. Zdjฤ…ฤ‡ starฤ… skรณrฤ™ ramienia symulatora, ล›ciฤ…gajฤ…c jฤ… w dรณล‚ przez ramiฤ™ i dล‚oล„ lub *rozcinajฤ…c.

Aby podล‚ฤ…czyฤ‡ nowe ramiฤ™, naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci:

Czynnoล›ci konserwacyjne

Wymiana prawego ramienia z dostฤ™pem doลผylnym

1. Otworzyฤ‡ korpus; patrz sekcja โ€žOtwieranie korpusuโ€.

2. Zdemontowaฤ‡ stare ramiฤ™, odkrฤ™cajฤ…c ล›rubฤ™ mocujฤ…cฤ… ramiฤ™ do barku symulatora.

3. Upewniฤ‡ siฤ™, ลผe ล›ruba barku jest na tyle poluzowana, aby umoลผliwiฤ‡ ล‚atwe zsuniฤ™cie osi ramienia.

4. Zutylizowaฤ‡ stare ramiฤ™ zgodnie z okreล›lonymi wytycznymi.

1. Upewniฤ‡ siฤ™, ลผe ล›ruba barku jest na tyle luลบna, aby umoลผliwiฤ‡ ล‚atwe wsuniฤ™cie osi ramienia.

2. Podล‚ฤ…czyฤ‡ ramiฤ™ do odpowiednich punktรณw przyล‚ฤ…czeniowych w korpusie.

3. Ostroลผnie wsunฤ…ฤ‡ oล› ramienia w zawias barkowy, tak aby znalazล‚a siฤ™ w tej samej pล‚aszczyลบnie, co wnฤ™trze zawiasu.

4. Dokrฤ™ciฤ‡ ล›rubฤ™ barku kluczem imbusowym.

Wymiana prawej nogi z dostฤ™pem ล›rรณdkostnym Aby odล‚ฤ…czyฤ‡ dolnฤ… czฤ™ล›ฤ‡ prawej nogi, naleลผy wykonaฤ‡ nastฤ™pujฤ…ce czynnoล›ci:

1. Upewniฤ‡ siฤ™, ลผe z nogi wypuszczono caล‚kowicie pล‚yn.

2. Zdemontowaฤ‡ starฤ… nogฤ™ z dostฤ™pem ล›rรณdkostnym, odkrฤ™cajฤ…c ล›rubฤ™ mocujฤ…cฤ… jฤ… do uda.

3. Wysunฤ…ฤ‡ dolnฤ… czฤ™ล›ฤ‡ nogi z dostฤ™pem ล›rรณdkostnym z uda.

4. Zutylizowaฤ‡ starฤ… nogฤ™ z dostฤ™pem ล›rรณdkostnym zgodnie z okreล›lonymi wytycznymi.

Aby zamontowaฤ‡ nowฤ… nogฤ™ z dostฤ™pem ล›rรณdkostnym, naleลผy przeprowadziฤ‡ opisane czynnoล›ci w odwrotnej kolejnoล›ci.

Ostrzeลผenie: *Nie wolno dziurawiฤ‡ ani nacinaฤ‡ trzpienia ramienia.

2. Zutylizowaฤ‡ starฤ… skรณrฤ™.

3. Nawilลผyฤ‡ wnฤ™trze nowej skรณry ramienia ล‚agodnym detergentem wymieszanym z wodฤ….

4. Nawilลผyฤ‡ (lub namydliฤ‡) trzpieล„ mieszaninฤ… mydล‚a w pล‚ynie i wody.

5. Wsunฤ…ฤ‡ rฤ™kฤ™ symulatora do skรณry.

6. Nasunฤ…ฤ‡ skรณrฤ™ na palce, jak rฤ™kawiczkฤ™.

7. Nastฤ™pnie naciฤ…gnฤ…ฤ‡ skรณrฤ™ na pozostaล‚ฤ… czฤ™ล›ฤ‡ trzpienia.

Page 172: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

170

Rozwiฤ…zywanie problemรณw

Instalacja systemu

Problem

โ€ข Utrata danych lub caล‚kowita awaria systemu (ogรณlna awaria systemu).

Moลผliwe rozwiฤ…zanie

โ€ข W przypadku samoczynnego wyล‚ฤ…czenia siฤ™ systemu bฤ…dลบ utraty lub uszkodzenia wszystkich danych, naleลผy skontaktowaฤ‡ siฤ™ z regionalnym centrum serwisowym Laerdal.

LLEAPโ€ข Wybraฤ‡ seriฤ™ poleceล„ Pliki pomocy oprogramowania > LLEAP >

Rozwiฤ…zywanie problemรณw (pliki pomocy dostฤ™pne sฤ… z poziomu aplikacji Laerdal Simulation Home)

Laerdal Patient Monitorโ€ข Patrz Pliki pomocy oprogramowania > Laerdal Patient Monitor >

Rozwiฤ…zywanie problemรณw. (Pliki pomocy dostฤ™pne sฤ… z poziomu aplikacji Laerdal Simulation Home)

Podsumowania i rejestracja wideoโ€ข Patrz sekcja dotyczฤ…ca rozwiฤ…zywania problemรณw w pomocy

przeglฤ…darki SimView (pliki pomocy dostฤ™pne z poziomu ล‚ฤ…cza u doล‚u ekranu przeglฤ…darki SimView) sekcja dotyczฤ…ca rozwiฤ…zywania problemรณw w pomocy przeglฤ…darki SessionViewer Help (pliki pomocy dostฤ™pne z poziomu aplikacji Laerdal Simulation Home)

Symulator

Problem

โ€ข Nieprzewidywalne zachowanie.

Moลผliwe rozwiฤ…zania

โ€ข Nieprawidล‚owe dziaล‚anie symulatora moลผe byฤ‡ spowodowane przez poluzowane przewody, rurki lub zล‚ฤ…cza. Otworzyฤ‡ korpus i sprawdziฤ‡, czy ktรณrekolwiek podzespoล‚y zostaล‚y odล‚ฤ…czone lub czy sฤ… nieszczelne. Patrz sekcja: Konfiguracja symulatora โ€” Otwieranie korpusu.

โ€ข W przypadku wycieku pล‚ynรณw naleลผy wyล‚ฤ…czyฤ‡ zasilanie symulatora i skontaktowaฤ‡ siฤ™ z serwisem technicznym firmy Laerdal.

Zanieczyszczenie drรณg oddechowych

Problem

โ€ข Doszล‚o do zanieczyszczenia drรณg oddechowych symulatora w wyniku oddychania metodฤ… usta-usta.

Moลผliwe rozwiฤ…zanie

โ€ข Wyczyล›ciฤ‡ zewnฤ™trzne czฤ™ล›ci symulatora chusteczkami do czyszczenia symulatora. Wyczyล›ciฤ‡ wnฤ™trze jamy ustnej chusteczkami do czyszczenia symulatora. Wymieniฤ‡ worek pล‚ucny; patrz sekcja: Czynnoล›ci obsล‚ugowe โ€” Wymiana worka pล‚ucnego.

Ruch klatki piersiowej

Problem

โ€ข Brak ruchu klatki piersiowej symulatora.

Moลผliwe rozwiฤ…zania

โ€ข Upewniฤ‡ siฤ™, ลผe zasilanie symulatora jest wล‚ฤ…czone.

โ€ข Przy uลผyciu urzฤ…dzenia SimPad lub aplikacji LLEAP sprawdziฤ‡, czy โ€“ wartoล›ฤ‡ parametru awRR nie jest ustawiona na zero

โ€“ Opcja โ€žUnoszenie klatki piersiowejโ€ nie jest wyล‚ฤ…czona

โ€“ EKG jest ustawione na rytm perfuzyjny.

โ€“ Sprawdziฤ‡, czy nie doszล‚o do powikล‚aล„ w obrฤ™bie drรณg oddechowych, np. czy nie ustawiono maksymalnego oporu powietrza lub kurczu krtani.

โ€“ Sprawdziฤ‡, czy w oprogramowaniu LLEAP wล‚ฤ…czona jest sprฤ™ลผarka wewnฤ™trzna. Patrz sekcja: Wyล‚ฤ…czanie sprฤ™ลผarki wewnฤ™trznej.

โ€ข Sprawdziฤ‡, czy wszystkie zewnฤ™trzne ลบrรณdล‚a sprฤ™ลผonego powietrza sฤ… wyล‚ฤ…czone oraz czy rurka powietrzna nie zostaล‚a odล‚ฤ…czona od symulatora.

โ€ข Sprฤ™ลผarka wewnฤ™trzna mogล‚a siฤ™ przegrzaฤ‡. Odczekaฤ‡ okoล‚o 20 minut do wychล‚odzenia.

โ€ข Unoszenie klatki piersiowej ustawiono na obustronne (np. rurka dotchawicza zostaล‚a wprowadzona za gล‚ฤ™boko do oskrzeli).

โ€ข Worek do symulacji unoszenia klatki piersiowej jest nieszczelny bฤ…dลบ rurki do worka sฤ… poskrฤ™cane, zgniecione lub odล‚ฤ…czone. Wymieniฤ‡ worek do symulacji unoszenia klatki piersiowej w przypadku nieszczelnoล›ci; patrz sekcja: Czynnoล›ci obsล‚ugowe Wymiana worka do symulacji unoszenia klatki piersiowej.

โ€ข Sprawdziฤ‡, czy rurki powietrza nie przeciekajฤ… i czy wszystkie podล‚ฤ…czenia sฤ… szczelne. Wymieniฤ‡ rurki w przypadku nieszczelnoล›ci.

โ€ข Pล‚ytkie ruchy klatki piersiowej pomimo ciฤ…gล‚ej pracy sprฤ™ลผarki wewnฤ™trznej. Sprฤ™ลผarka wewnฤ™trzna mogล‚a siฤ™ zuลผyฤ‡. Skontaktuj siฤ™ z serwisem technicznym firmy Laerdal.

Pล‚uca Problem

โ€ข Pล‚uca nie funkcjonujฤ… prawidล‚owo

Moลผliwe rozwiฤ…zania

โ€ข Otworzyฤ‡ korpus i pล‚ytฤ™ klatki piersiowej. Sprawdziฤ‡, czy pล‚uca majฤ… doล›ฤ‡ miejsca, by siฤ™ rozszerzaฤ‡ oraz czy ich ruch nie jest ograniczony przez przewody.

โ€ข Sprawdziฤ‡, czy worek pล‚ucny zostaล‚ prawidล‚owo podล‚ฤ…czony i czy nie doszล‚o do skrฤ™cenia rurek.

โ€ข Sprawdziฤ‡, czy worek pล‚ucny znajduje siฤ™ w poล‚oลผeniu poziomym i czy zostaล‚ prawidล‚owo wล‚oลผony.

Page 173: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

171

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

C

zynn

oล›ci

ko

nser

wac

yjne

C

zฤ™ล›c

i zam

ienn

e i a

kces

oria

Spec

yfika

cje

W

stฤ™p

Ro

zwiฤ…

zyw

anie

pr

oble

mรณw

Rozwiฤ…zywanie problemรณw

โ€ข Sprawdziฤ‡, czy worek pล‚ucny nie zostaล‚ uszkodzony lub rozerwany.

โ€ข Sprawdziฤ‡, czy w drogach oddechowych symulatora nie ma przeszkรณd blokujฤ…cych przepล‚yw powietrza.

โ€ข Jeล›li regulacja podatnoล›ci pล‚uc nie spowoduje ลผadnej zmiany, naleลผy skontaktowaฤ‡ siฤ™ z serwisem technicznym firmy Laerdal.

โ€ข Jeล›li opรณr pล‚ucny nie zmieni siฤ™, naleลผy skontaktowaฤ‡ siฤ™ z serwisem technicznym firmy Laerdal.

Haล‚as mechaniczny podczas osล‚uchiwaniaW aplikacji LLEAP naleลผy kliknฤ…ฤ‡ polecenie <Obszar osล‚uchowy>.

Tฤ™tno (tฤ™tnica promieniowa i ramienna)

Problem

โ€ข Niewyczuwalne tฤ™tno

Moลผliwe rozwiฤ…zania

โ€ข Skรณra na elementach generujฤ…cych tฤ™tno moลผe byฤ‡ za bardzo naciฤ…gniฤ™ta โ€” poprawiฤ‡ uล‚oลผenie skรณry i uruchomiฤ‡ ponownie.

โ€ข Sprawdziฤ‡, czy ciล›nienie skurczowe zostaล‚o ustawione na wartoล›ฤ‡ co najmniej 60.

โ€ข Upewniฤ‡ siฤ™, ลผe sprฤ™ลผarka jest wล‚ฤ…czona.

Uwaga: jeล›li tฤ™tno w tฤ™tnicy promieniowej zostaล‚o ustawione na wartoล›ฤ‡ poniลผej 60, tฤ™tno obwodowe moลผe zanikaฤ‡.

Wyล‚ฤ…czanie symulatora

Problem

โ€ข Symulator nie odpowiada.

Rozwiฤ…zanie

1. Wyล‚ฤ…czyฤ‡ urzฤ…dzenie Link Box.

2. Wyล‚ฤ…czyฤ‡ urzฤ…dzenie SimPad; w przypadku korzystania z aplikacji LLEAP wyล‚ฤ…czyฤ‡ komputer instruktora.

3. Zrestartowaฤ‡ wszystkie urzฤ…dzenia.

Jeล›li symulator nadal nie odpowiada, naleลผy skontaktowaฤ‡ siฤ™ z przedstawicielem firmy Laerdal.

Page 174: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

172

Uwagi

Page 175: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

173

Opr

ogra

mow

anie

do

 sym

ulac

ji Ko

nfigu

racj

a sy

mul

ator

a

Czy

nnoล›

ci

kons

erw

acyj

ne

Czฤ™

ล›ci z

amie

nne

i akc

esor

iaSp

ecyfi

kacj

e

Wst

ฤ™p

Rozw

iฤ…zy

wan

ie

prob

lem

รณw

Specyfikacje

Wymiary caล‚kowite Dล‚ugoล›ฤ‡/szerokoล›ฤ‡ (tylko symulator): 120 cm x 42,5 cm Waga (tylko symulator): 11,36 kg

Zasilanie symulatora Zasilanie zewnฤ™trzne: Napiฤ™cie wejล›ciowe: 9 V DC, 1,5 A Akumulator wewnฤ™trzny: 7,4 V, 4,4 Ah, litowo-jonowy

Naleลผy uลผywaฤ‡ wyล‚ฤ…cznie akumulatorรณw i zewnฤ™trznych ลบrรณdeล‚ zasilania zatwierdzonych do stosowania z symulatorem SimJunior.

Ciล›nienie powietrza Wewnฤ™trzny zbiornik powietrza: Maks. 6 psi Zewnฤ™trzne zล‚ฤ…cze powietrza: Maks. 16 psi

Zakres dopuszczalnych temperatur Zakres temperatury pracy: +4ยบC do +40ยบC Zakres temperatury przechowywania: -15ยบC do +50ยบC

Otoczenie โ€” tylko symulator Wilgotnoล›ฤ‡ wzglฤ™dna: 20โ€“90% (bez kondensacji) NIE uลผywaฤ‡ na zewnฤ…trz w wilgotnym otoczeniu. Nie badano w ล›rodowisku zawierajฤ…cym powietrznฤ… zawiesinฤ™ soli.

Komunikacja radiowa Zakres dziaล‚ania: maks. 10 m

Tabela materiaล‚รณw symulatora Ubrania: baweล‚na, nylon Skรณra i drogi oddechowe: PCW Zewnฤ™trzne twarde tworzywa sztuczne: PCW, ABS Tworzywa wewnฤ™trzne: silikon, TPU (termoplastyczne

elastomery poliuretanowe), PCW, nitryl ABS, POM, nylon + epoksypoliuretan GF

Elementy metalowe: aluminium, mosiฤ…dz, stal

Uwaga, lateks: ten produkt zawiera naturalny lateks, ktรณry moลผe wywoล‚ywaฤ‡ reakcje alergiczne u osรณb uczulonych.

Minimalne wymagania sprzฤ™towe

โ€ข Procesor Intel i-core trzeciej generacji lub nowszy

โ€ข Ponad 3000 punktรณw w teล›cie PassMark โ€“ Oznaczenie CPU

โ€ข 4 GB RAM

โ€ข 120 GB miejsca na dysku

โ€ข 1366 x 768 lub wiฤ™cej

โ€ข Zestaw sล‚uchawkowy z mikrofonem

โ€ข Porty USB โ€“ 2

Minimalne wymagania dotyczฤ…ce oprogramowania

โ€ข Windows 7 lub Windows 8

โ€ข 100% DPI

Pล‚yny do czyszczenia Do czyszczenia symulatora naleลผy uลผywaฤ‡ jednego z nastฤ™pujฤ…cych ล›rodkรณw:

โ€“ 60% alkohol izopropylowy

โ€“ 70% etanol

โ€“ ล‚agodny roztwรณr mydล‚a w pล‚ynie i wody.

Pล‚yny podawane doลผylnie Naleลผy stosowaฤ‡ wyล‚ฤ…cznie wodฤ™ destylowanฤ… lub zdejonizowanฤ… do symulowania pล‚ynรณw podawanych doลผylnie i ล›rรณdkostnie.

Page 176: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

174

Uwagi

Page 177: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

175

Opr

ogra

mow

anie

do

 sym

ulac

ji

Konfi

gura

cja

sym

ulat

ora

Czy

nnoล›

ci

kons

erw

acyj

ne

Czฤ™

ล›ci z

amie

nne

i akc

esor

iaSp

ecyfi

kacj

e

Wst

ฤ™p

Rozw

iฤ…zy

wan

ie

prob

lem

รณw

Czฤ™ล›ci zamienne i akcesoria

Czฤ™ล›ci zamienne i akcesoria Najnowszฤ… wersjฤ™ rozdziaล‚u โ€žCzฤ™ล›ci zamienne i akcesoriaโ€ moลผna znaleลบฤ‡ na stronie www.laerdal.com.

Page 178: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

176

Uwagi

Page 179: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

177

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น 188

โ€“ ๅ„ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒใ‚ทใƒงใƒณๅพŒใฎใƒกใƒณใƒ†ใƒŠใƒณใ‚น 188 โ€“ ไธŠๅŠ่บซใ‚’้–‹ใ 189 โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชไบคๆ› 189 โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชๅ……้›ป 190 โ€“ ๅ‘ผๅธใƒใƒซใƒผใƒณใฎไบคๆ› 190โ€“ ่‚บใฎไบคๆ› 190 โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚นใ‚ญใƒณใฎไบคๆ› 191 โ€“ ๅณ IV ใ‚ขใƒผใƒ ใฎไบคๆ› 191 โ€“ ๅณ IO ใƒฌใƒƒใ‚ฐใฎไบคๆ› 191

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ 192

ใฏใ˜ใ‚ใซ 178

โ€“ ่ฆๅˆถๆƒ…ๅ ฑ 178โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎไธ€่ˆฌ็š„ใชใŠๆ‰‹ๅ…ฅใ‚Œ 179โ€“ SimJunior ๅ…จไฝ“ๅ†™็œŸ 181 โ€“ SimJunior ใฎๆฉŸ่ƒฝ 182

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ— 185

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใฎๆบ–ๅ‚™ 185โ€“ IO ใƒฌใƒƒใ‚ฐใฎๆบ–ๅ‚™ 185 โ€“ IV ๆถฒใฎๆŠ•ไธŽ 185 โ€“ ไฝ™ๅ‰ฐ IV ๆถฒใฎๆŽ’ๅ‡บ 186 โ€“ IV ใ‚ขใƒผใƒ ใฎใ‚ฏใƒชใƒผใƒ‹ใƒณใ‚ฐ 186 โ€“ ้™ค็ดฐๅ‹•ใ‚ขใƒ€ใƒ—ใ‚ฟใƒ—ใƒฌใƒผใƒˆใฎๅ–ใ‚Šไป˜ใ‘ 186 โ€“ ่ก€ๅœง่จˆใ‚ซใƒ•ใฎๆŽฅ็ถš 186 โ€“ LLEAP ใงใฎ่ก€ๅœง่จˆใ‚ซใƒ•ใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ 186 โ€“ SimPad ใงใฎ่ก€ๅœง่จˆใ‚ซใƒ•ใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ 186โ€“ ็žณๅญ”ใฎไบคๆ› 187โ€“ ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใฎไฝฟ็”จ 187

ไป•ๆง˜ 195

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข 184

โ€“ ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC 184โ€“ ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใƒฉใ‚คใ‚ปใƒณใ‚น 184 โ€“ Laerdal Simulation Home 184โ€“ LLEAP 184โ€“ Voice Conference Application 184โ€“ Patient Monitor 184โ€“ Session Viewer ใŠใ‚ˆใณ SimView Server 184โ€“ ใใฎไป–ใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณ 184โ€“ SimDesigner 184โ€“ ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซ 184โ€“ ใ‚ฆใ‚งใƒ–ใƒ€ใ‚ฆใƒณใƒญใƒผใƒ‰ 184

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช 197

็›ฎๆฌก JA

Page 180: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

178

SimJuniorโ„ข ใฎใ”็ดนไป‹ SimJunior ใฏ็ฑณๅ›ฝๅฐๅ…็ง‘ๅญฆไผšใฎๅ”ๅŠ›ใซใ‚ˆใ‚Šใƒฌใƒผใƒซใƒ€ใƒซใŒ่จญ่จˆใ—ใŸใƒชใ‚ขใƒซ ใช็ญ‰่บซๅคงใฎๅฐๅ…ๆ‚ฃ่€…ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใงใ™ใ€‚SiimJunior ใฏใ€ๅคšๅฒใซใ‚ใŸใ‚‹ ๅŒป็™‚ๅฐ‚้–€ๅˆ†้‡ŽใซใŠใ‘ใ‚‹ๅ€‹ไบบใ€ใพใŸใฏๅŒป็™‚ๅพ“ไบ‹่€…ใƒใƒผใƒ ใฎๆ•™่‚ฒใซไฝฟ็”จใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚

SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฏใ€ๅฎŒๅ…จใซ็ต„ใฟ็ซ‹ใฆใ‚‰ใ‚ŒใŸๅฝขใง็ดๅ“ใ•ใ‚Œใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒ‘ใƒผใƒ„ใ‚’็ต„ใฟ็ซ‹ใฆใ‚‹ๅฟ…่ฆใฏใ‚ใ‚Šใพใ›ใ‚“ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใฎใŸใ‚ใฎ SimJunior ใฎๆบ–ๅ‚™ใฎ่ฉณ็ดฐใซใคใ„ใฆใฏใ€ ใ€Œใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—ใ€ใฎ็ซ ใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

SimJunior ใƒ˜ใƒซใƒ— ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธ (DFU)

SimJunior ใฎไฝฟ็”จๆ‰‹้ †ใ‚’็คบใ—ใŸใ€ๆฎต้šŽใ”ใจใฎ่ชฌๆ˜Žใจๅ›ณ่งฃใงใ™ใ€‚

่ฃฝ้€ ๅ…ƒใฎๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธ ่ฃฝ้€ ๅ…ƒใŒๅˆฅ้€”ไฝœๆˆใ—ใŸใ™ในใฆใฎๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใ‚„ๆทปไป˜ๆ–‡ๆ›ธ็ญ‰ใฎๆณ•ๅฎš่กจ็คบใซๅพ“ใฃใฆใใ ใ•ใ„ใ€‚SimJunior ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใฏใ€่ฃฝ้€ ๅ…ƒใŒๆไพ›ใ—ใŸใƒžใƒ‹ใƒฅใ‚ขใƒซ็ญ‰ใซไปฃใ‚ใ‚‹ใ‚‚ใฎใงใฏใชใใ€ใพใŸๅ„ชๅ…ˆใ™ใ‚‹ใ‚‚ใฎใงใ‚‚ใ‚ใ‚Šใพใ›ใ‚“ใ€‚

SimJunior ใ‚ฏใ‚คใƒƒใ‚ฏใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—ใ‚ฌใ‚คใƒ‰ SimJunior ใ‚’ไฝฟ็”จใ™ใ‚‹้š›ใฎๆ‰‹้ †ใ‚’็คบใ—ใŸใ€ๆฎต้šŽใ”ใจใฎ่ชฌๆ˜Žใ‚ฌใ‚คใƒ‰ใงใ™ใ€‚

SimPad ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธ (DFU)

SimPad ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใซใฏใ€Link Box ใจ SimPad ใ‚’ SimJunior ใงไฝฟ็”จใ™ใ‚‹ๆ‰‹้ †ใ‚’่งฃ่ชฌใ—ใฆใ„ใพใ™ใ€‚

LLEAP (Laerdal Learning Application) ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซLLEAP ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซใฏใ€Laerdal Simulation Home ใ‹ใ‚‰ใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝใงใ™ใ€‚Laerdal Simulation Home ใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

ใƒ˜ใƒซใƒ—ใฎใƒˆใƒ”ใƒƒใ‚ฏใฏไปฅไธ‹ใฎ้€šใ‚Šใงใ™๏ผš

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ตใƒใƒผใƒˆ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ตใƒใƒผใƒˆใซใคใ„ใฆใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผ ใพใงใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

ใ‚ฆใ‚งใƒ–ใƒ€ใ‚ฆใƒณใƒญใƒผใƒ‰ www.laerdal.com/downloads ใ‹ใ‚‰ใ€ๆœ€ๆ–ฐใฎๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใŠใ‚ˆใณใ‚ทใƒŸใƒฅ ใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใฎๆœ€ๆ–ฐใƒใƒผใ‚ธใƒงใƒณใ‚’ใƒ€ใ‚ฆใƒณใƒญใƒผใƒ‰ใงใใพใ™ใ€‚

SimStore ใ‚ณใƒณใƒ†ใƒณใƒ„ SimStore ใงใฏใ€ไธ–็•Œไธญใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณๅฐ‚้–€ๅฎถใซใ‚ˆใ‚‹ๆคœ่จผๆธˆใฎ ใ‚ณใƒณใƒ†ใƒณใƒ„ใซ็ฐกๅ˜ใซใ‚ขใ‚ฏใ‚ปใ‚นใงใใ‚‹ใŸใ‚ใ€ใใฎ็ตŒ้จ“ใ‚’็”Ÿใ‹ใ—ใฆใ€ ใ‚ใ‚‰ใ‚†ใ‚‹ๅญฆ็ฟ’ใฎๆฉŸไผšใ‚’ๆœ€ๅคง้™ใซๆดป็”จใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚SimJunior ๅฐ‚็”จใซ้–‹็™บใ•ใ‚ŒใŸๆง˜ใ€…ใชใ‚ทใƒŠใƒชใ‚ชใŒไฝฟ็”จใงใใพใ™ใ€‚่ฉณ็ดฐใซใคใ„ใฆใฏใ€ www.mysimcenter.com ใงใ”็ขบ่ชใใ ใ•ใ„ใ€‚

่ฆๅˆถๆƒ…ๅ ฑ

Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

ๆณจๆ„ ใ‚ณใƒณใƒ—ใƒฉใ‚คใ‚ขใƒณใ‚นใฎ่ฒฌไปปใ‚’ๆœ‰ใ™ใ‚‹ๅฝ“ไบ‹่€…ใฎๆ˜Ž็คบ็š„ใชๆ‰ฟ่ชใชใ—ใซๅค‰ๆ›ดใ‚„ๆ”น้€ ใ‚’่กŒใฃใŸๅ ดๅˆใ€ๆฉŸๅ™จใ‚’ๆ“ไฝœใ™ใ‚‹ใƒฆใƒผใ‚ถใƒผๆจฉ้™ใŒ็„กๅŠนใจใชใ‚‹ ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚

Li-ion

ใƒชใƒใ‚ฆใƒ ใ‚คใ‚ชใƒณใƒใƒƒใƒ†ใƒชใฏใƒชใ‚ตใ‚คใ‚ฏใƒซใ—ใฆใใ ใ•ใ„ใ€‚

ๆœฌ่ฃฝๅ“ใฏใ€EMC ใซ้–ขใ™ใ‚‹ EU ๆŒ‡ไปค 2004/108/EC ใฎๅŸบๆœฌ่ฆไปถใซๆบ–ๆ‹ ใ—ใฆใ„ใพใ™ใ€‚

ๆœฌ่ฃฝๅ“ใฏใ€็‰นๅฎšๆœ‰ๅฎณ็‰ฉ่ณชไฝฟ็”จๅˆถ้™ (RoHS) ใซ้–ขใ™ใ‚‹ EU ๆŒ‡ไปค 2011/65/EU ใซๆบ–ๆ‹ ใ—ใฆใ„ใพใ™ใ€‚

ๅ„ๅœฐๅŸŸใฎ่ฆไปถใ‚„่ฆๅ‰‡ใซๅ‰‡ใ‚Šๅปƒๆฃ„ใ—ใฆใใ ใ•ใ„ใ€‚

ใฏใ˜ใ‚ใซ

ๅ…่ฒฌๆก้ … ใ‚นใ‚ฟใƒƒใƒ•่จ“็ทดใฎใŸใ‚ใฎ SimJunior ๆ‚ฃ่€…ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ทใ‚นใƒ†ใƒ ใฎไฝฟ็”จใฏใ€ๆ•™่‚ฒๅŽŸ็†ใ‚’็†่งฃใ—ใ€ๅบƒใ่ชใ‚ใ‚‰ใ‚ŒใŸๅŒป็™‚ใƒ—ใƒญใƒˆใ‚ณใƒซใ‚’็†่งฃใ—ใฆใ„ใ‚‹้ฉๅˆ‡ใช่จ“็ทดใ‚’ๅ—ใ‘ใŸๆŠ€่ก“่€…ใ€ใพใŸใฏๅŒป็™‚ๅพ“ไบ‹่€…ใฎ็›ฃ็ฃใฎใ‚‚ใจใซ่กŒใ‚ใ‚Œใ‚‹ๅฟ…่ฆใŒใ‚ใ‚Šใพใ™ใ€‚ใ™ในใฆใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚„ใใฎไป–ใฎ ็ ”ไฟฎ็”จๆฉŸ ๅ™จใจๅŒๆง˜ใ€่งฃๅ‰–ๅญฆ็š„็‰นๅพดใ‚„็”Ÿ็†ๅญฆ็š„ใƒขใƒ‡ใƒซใซใฏ่ฟ‘ไผผใ€ๅๅทฎใŠใ‚ˆใณไธๆญฃ็ขบๆ€งใŒๅญ˜ๅœจใ™ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚ใใฎใŸใ‚ใ€ใƒฌใƒผใƒซใƒ€ใƒซ ใฏใ™ในใฆใฎๆฉŸ่ƒฝใฎๅฎŒๅ…จใชๆญฃ็ขบๆ€งใ‚’ไฟ่จผใ™ใ‚‹ใ‚‚ใฎใงใฏใ‚ใ‚Šใพใ›ใ‚“ใ€‚

Page 181: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

179

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎไธ€่ˆฌ็š„ใชใŠๆ‰‹ๅ…ฅใ‚Œ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒ‘ใƒ•ใ‚ฉใƒผใƒžใƒณใ‚นใ‚’ๆœ€้ฉใซไฟใกใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใŠใ‚ˆใณใใฎ้ƒจๅ“ใฎ่€ไน…ๆ€งใ‚’ไฟใคใŸใ‚ใซใ€ไปฅไธ‹ใฎๆŒ‡็คบใซๅพ“ใฃใฆใใ ใ•ใ„ใ€‚

ไธ€่ˆฌ็š„ใชใŠๆ‰‹ๅ…ฅใ‚Œ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚นใ‚ญใƒณใฎ็Šถๆ…‹ใ‚’็ถญๆŒใ™ใ‚‹ใŸใ‚ใซใ€ไฝฟ็”จๅ‰ใซๆ‰‹ใ‚’ๆด—ใ„ใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ๆธ…ๆฝ”ใชใจใ“ใ‚ใซ็ฝฎใ„ใฆใใ ใ•ใ„ใ€‚ใƒฌใƒผใƒซใƒ€ใƒซใงใฏใ€ไปฅไธ‹ใ‚’ใŠๅ‹งใ‚ใ—ใฆใ„ใพใ™๏ผš

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ทใƒŠใƒชใ‚ชไธญใฏๆ‰‹่ข‹ใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚นใ‚ญใƒณใŒๅค‰่‰ฒใ™ใ‚‹ๅ ดๅˆใŒใ‚ใ‚‹ใฎใงใ€่‰ฒใคใใฎใ‚ดใƒ ๆ‰‹่ข‹ใฏไฝฟ็”จใ—ใชใ„ใ‚ˆใ†ใซใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใใฐใงใ€ใƒ•ใ‚งใƒซใƒˆใƒšใƒณใ€ใ‚คใƒณใ‚ฏใƒšใƒณใ€ใ‚ขใ‚ปใƒˆใƒณใ€ ใƒจใ‚ฆ็ด ใ€ใพใŸใฏใใฎไป–ใฎๆŸ“่‰ฒ่–ฌๅ‰คใ‚’ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ๆ–ฐ่ž็ด™ใ‚„่‰ฒใฎใคใ„ใŸ็ด™ใฎไธŠใซ็ฝฎใ‹ใชใ„ใ‚ˆใ†ๆณจๆ„ใ—ใฆใใ ใ•ใ„ใ€‚ๆฑšใ‚ŒใŒๅ–ใ‚Œใชใใชใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚นใ‚ญใƒณใฏไฝŽๅˆบๆฟ€ๆ€งใฎ็Ÿณ้นธใจๆฐดใงๆด—ๆต„ใ—ใฆใใ  ใ•ใ„ใ€‚

ๆฐ—้“ใฏ้ฉๅˆ‡ใซๆถˆๆฏ’ใงใใชใ„ใŸใ‚ใ€ๆœฌใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใงใฏไปฅไธ‹ใฎๆ‰‹ๆŠ€ใ‚’ๅฎŸ่กŒใ—ใชใ„ใงใใ ใ•ใ„๏ผš

โ€“ ๅฃๅฏพๅฃ/ๅฃๅฏพใƒžใ‚นใ‚ฏไบบๅทฅๅ‘ผๅธ

โ€“ ๅธๅผ•ใฎใŸใ‚ใฎๆจกๆ“ฌๅ็€‰็‰ฉใพใŸใฏๆถฒไฝ“ใฎๆŒฟๅ…ฅ

โ€“ ใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใ‚ปใƒƒใ‚ทใƒงใƒณใซ IV ใ‚ขใƒผใƒ ๅ†…ใงใฎๆถฒไฝ“ไฝฟ็”จใŒๅซใพใ‚Œใ‚‹ๅ ดๅˆใฏใ€ใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใ‚ปใƒƒใ‚ทใƒงใƒณใŒ็ต‚ใ‚ใ‚Šๆฌก็ฌฌใ€ใ‚ขใƒผใƒ ๅ†…ใ‹ใ‚‰ใฎๆŽ’ๅ‡บใ‚’่กŒใฃใฆใใ ใ•ใ„ใ€‚

โ€“ ใƒฌใƒผใƒซใƒ€ใƒซ็คพ่ฃฝใฎๆฝคๆป‘ใ‚นใƒ—ใƒฌใƒผใฎใฟใ‚’ใ€ๅฐ‘้‡ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆง‹ๆˆใƒขใ‚ธใƒฅใƒผใƒซใฏใ€ๆด—ๆต„ใ—ใ€ใ™ใ™ใ„ใ ไธŠใงใ€ ไนพใ‹ใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ่ƒดไฝ“ใฎใ‚นใ‚ญใƒณใ‚’่ฃ่ฟ”ใ—ใ€ใ‚นใ‚ญใƒณใฎๅ†…ๅดใซใƒ‘ใ‚ฆใƒ€ใƒผๅก—ๅธƒใ™ใ‚‹ใจ ๆ‘ฉๆ“ฆใ‚’ๆธ›ใ‚‰ใ™ใ“ใจใŒใงใใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒธ้ƒจๅ†…ใซใ€ ใƒ‘ใ‚ฆใƒ€ใƒผใ‚’ใ“ใผใ•ใชใ„ใ‚ˆใ†ใซใ—ใฆใใ ใ•ใ„ใ€‚

็’ฐๅขƒ ๅฏ’ๅ†ทๆกไปถไธ‹ใงใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใŒๅฎคๆธฉใซใชใ‚‹ใฎใ‚’ๅพ…ใฃใฆใ‹ใ‚‰ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

ใ‚ชใƒผใƒใƒผใƒ’ใƒผใƒˆใ‚’้˜ฒใŽใ€ๆ‘ฉ่€—ใ‚’ๆธ›ใ‚‰ใ™ใซใฏ๏ผš

โ€“ 40ยฐC ใ‚’่ถ…ใˆใ‚‹ๆธฉๅบฆใงไฝฟ็”จใ™ใ‚‹้š›ใฏใ€ๅธธใซใ‚ปใƒƒใ‚ทใƒงใƒณใจใ‚ปใƒƒใ‚ทใƒงใƒณ ใฎ้–“ใซใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ใ‚ฏใƒผใƒซใƒ€ใ‚ฆใƒณใ•ใ›ใพใ™ใ€‚

โ€“ ใƒ™ใƒƒใƒ‰ใงไฝฟ็”จใ™ใ‚‹้š›ใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‹ใ‚‰ใฎๆ”พ็†ฑใ‚’ๅฆจใ’ใ‚‹ๆใ‚ŒใŒใ‚ใ‚‹ใŸใ‚ใ€ๅŽšใ„ๅฏๅ…ทใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’่ฆ†ใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅ–ๆ‰ฑใ„ใซใคใ„ใฆ ๆ€ชๆˆ‘ใพใŸใฏ่ฃฝๅ“ใธใฎๆๅ‚ทใ‚’้ฟใ‘ใ‚‹ใŸใ‚ใซใ€ไปฅไธ‹ใซๆณจๆ„ใ—ใฆใใ ใ•ใ„๏ผš

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซๆถฒไฝ“ใ‚’ๆณจๅ…ฅใ™ใ‚‹้š›ใฏใ€ๅฟ…ใšๆœฌๆ›ธใฎๆŒ‡็คบใซๅพ“ใฃใฆใใ ใ•ใ„ใ€‚

โ€“ ๆ›ๆฐ—็”จใฎๅ„็จฎๅ™จๅ…ทใ‚„ใƒใƒฅใƒผใƒ–ใ‚’ๆŒฟๅ…ฅใ™ใ‚‹้š›ใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซ็คพ่ฃฝๆฝคๆป‘ใ‚นใƒ—ใƒฌใƒผใ‚’ๅฃ่…”ใŠใ‚ˆใณ้ผป่…”ๆฐ—้“ใซๅก—ๅธƒใ—ใฆใใ ใ•ใ„ใ€‚ ใพใŸใ€ไฝฟ็”จๅ‰ใซๅ™จๅ…ทใŠใ‚ˆใณใƒใƒฅใƒผใƒ–ใซใ‚‚ๆฝคๆป‘ใ‚นใƒ—ใƒฌใƒผใ‚’ๅก—ๅธƒใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ไบบๅทฅๅ‘ผๅธใชใฉใฎ้š›ใซๅŠ ๆนฟใฏ่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ๅ†…้ƒจใƒใƒฅใƒผใƒ–ใ‚„ใ‚ฑใƒผใƒ–ใƒซใŒๅˆ‡ใ‚Œใฆใ„ใ‚‹ๅ ดๅˆใฏใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ๅฑ‹ๅค–ใง้›จๅคฉๆ™‚ใชใฉใฎๆนฟๅบฆใฎ้ซ˜ใ„็’ฐๅขƒใงๆ‚ฃ่€…ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ไฝฟ็”จใ™ใ‚‹ใ“ใจใฏใŠใ‚„ใ‚ใใ ใ•ใ„ใ€‚ๆ„Ÿ้›ปใฎๅฑ้™บๆ€งใ‚„ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ ๆๅ‚ทใŒ็”Ÿใ˜ใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ 35ยฐC ใ‚’่ถ…ใˆใ‚‹ๆธฉๅบฆใง้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใ™ใ‚‹ใจใ‚ชใƒผใƒใƒผใƒ’ใƒผใƒˆใŒ็”Ÿใ˜ใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚

่ญฆๅ‘Š๏ผšใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใง่‡ชๅ‹•ๅฟƒใƒžใƒƒใ‚ตใƒผใ‚ธๅ™จใ‚’ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„

ใƒฉใƒ†ใƒƒใ‚ฏใ‚นใซ้–ขใ™ใ‚‹ๆณจๆ„๏ผšๆœฌ่ฃฝๅ“ใซใฏๅคฉ็„ถใ‚ดใƒ ใƒฉใƒ†ใƒƒใ‚ฏใ‚นใŒๅซใพใ‚ŒใฆใŠใ‚Šใ€ไบบไฝ“ใซๆŽฅ่งฆใ™ใ‚‹ใจใ‚ขใƒฌใƒซใ‚ฎใƒผๅๅฟœใ‚’ๅผ•ใ่ตทใ“ใ™ใ“ใจใŒใ‚ใ‚Šใพใ™ใ€‚

้™ค็ดฐๅ‹•ใฎๅฑ้™บ SimJunior ใงใฏ้™ค็ดฐๅ‹•ใŒๅฏ่ƒฝใงใ™ใ€‚

SimJunior ใงใฏ่‡จๅบŠ็”จใฎ้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใงใใพใ™ใ€‚้™ค็ดฐๅ‹•ไธญใ€้™ค็ดฐๅ‹•ๅ™จใ‚„ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซ่งฆใ‚Œใ‚‹ใจๆ„Ÿ้›ปใ™ใ‚‹ๅฑ้™บๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใง้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใ™ใ‚‹้š›ใฏใ€ใ™ในใฆใฎๆจ™ๆบ–็š„ๅฎ‰ๅ…จๆŽช็ฝฎใ‚’่ฌ›ใ˜ใฆใใ ใ•ใ„ใ€‚

โ€ข ้™ค็ดฐๅ‹•ๅ™จใŠใ‚ˆใณ้–ข้€ฃๆฉŸๅ™จใซๆทปไป˜ใ•ใ‚ŒใŸใ™ในใฆใฎๅฎ‰ๅ…จใŠใ‚ˆใณๆ“ไฝœใซ้–ขใ™ใ‚‹ๆŒ‡็คบใ‚’่ชญใฟใ€ๅพ“ใฃใฆใใ ใ•ใ„ใ€‚

โ€ข ้™ค็ดฐๅ‹•ใฎ้š›ใซใฏใ€้™ค็ดฐๅ‹•ใƒ‘ใƒ‰ใƒซใจ ECG ็ซฏๅญใŒๆŽฅ่งฆใ—ใชใ„ใ‚ˆใ†ใซใ—ใ€ๆญฃใ—ใ„ๆ‰‹้ †ใซๅพ“ใฃใฆใใ ใ•ใ„ใ€‚้™ค็ดฐๅ‹•ใ‚จใƒใƒซใ‚ฎใƒผใฏ 300 J ใพใงๅฎŸๆ–ฝใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚

โ€ข ๅฎ‰ๅ…จๅฏพ็ญ–ใ‚’่ฌ›ใ˜ใชใ„ๅ ดๅˆใฏใ€่ฒ ๅ‚ทใพใŸใฏๆญปไบกใ‚’ๅผ•ใ่ตทใ“ใ™ใŠใใ‚ŒใŒใ‚ใ‚Šใพใ™ใ€‚

่ฉณ็ดฐใซใคใ„ใฆใฏใ€้™ค็ดฐๅ‹•ๅ™จใฎ่ฃฝ้€ ๅ…ƒใŒๆไพ›ใ™ใ‚‹ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ้™ค็ดฐๅ‹•ใ‚’่กŒใ†้š›ใซใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒธ้ƒจใซใ‚ใ‚‹ๅฐ‚็”จใฎ้™ค็ดฐๅ‹•็”จ ใ‚ณใƒใ‚ฏใ‚ฟใพใŸใฏใƒ—ใƒฌใƒผใƒˆใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚ๅฟƒ้›ปๅ›ณใ‚ณใƒใ‚ฏใ‚ฟใซ ้™ค็ดฐๅ‹•ใฏ่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚ๅฟƒ้›ปๅ›ณใ‚ณใƒใ‚ฏใ‚ฟใงใฎ้™ค็ดฐๅ‹• ใซใ‚ˆใ‚Šใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๅ†…้ƒจใฎ้›ปๅญ้ƒจๅ“ใซใƒ€ใƒกใƒผใ‚ธใŒ็”Ÿใ˜ใ€ ไบบ่บซๅ‚ทๅฎณใŒ่ตทใ“ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใŒใ‚ชใƒ•ใซใชใฃใฆใ„ใ‚‹ๅ ดๅˆใ€ใพใŸใฏใƒžใƒใ‚ญใƒณใŒๆญฃๅธธใซๆฉŸ่ƒฝใ—ใฆใ„ใชใ„ๅ ดๅˆใฏใ€ใƒžใƒใ‚ญใƒณใซ้™ค็ดฐๅ‹•ใ‚’่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

ใฏใ˜ใ‚ใซ

ใ‚ฐใƒญใƒผใƒใƒซไฟ่จผ ใƒฌใƒผใƒซใƒ€ใƒซใ‚ฐใƒญใƒผใƒใƒซไฟ่จผๅ†Šๅญใ€ใพใŸใฏ www.laerdal.com/jp/ ใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

ๅŽŸ็”ฃๅ›ฝ - SimJunior ใฏใ€็ฑณๅ›ฝใง่ฃฝ้€ ใ•ใ‚Œใฆใ„ใพใ™ใ€‚

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 182: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

180

ใ‚ชใƒผใƒใƒผใƒ’ใƒผใƒˆใ‚’้˜ฒใใŸใ‚ใซใ€1 ๅˆ†้–“ใฎ CPR ๅพŒใซไธŽใˆใ‚‹้›ปๆฐ—ใ‚ทใƒงใƒƒใ‚ฏ ใฎ้ ปๅบฆใฏใ€45 ็ง’ใซ 3 ๅ›žใ‚’่ถ…ใˆใชใ„ใ‚ˆใ†ใซใ—ใฆใใ ใ•ใ„ใ€‚้™ค็ดฐๅ‹•ใ‚’ไผดใ†ใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใง 30 ๅˆ†ไปฅไธŠไฝฟ็”จใ—ใŸๅ ดๅˆใ€ๆฌกใฎไฝฟ็”จใฎๅ‰ใซๅฐ‘ใชใใจใ‚‚ 15 ๅˆ†้–“ใฏใ‚ทใƒงใƒƒใ‚ฏใ‚’่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚4 ๆ™‚้–“ใ‚’่ถ…ใˆใฆไฝœๅ‹•ใ‚’็นฐใ‚Š่ฟ”ใ•ใชใ„ใงใใ ใ•ใ„ใ€‚ ใพใŸใ€1 ๅˆ†้–“ใซ 2 x 300 ใ‚’่ถ…ใˆใ‚‹้™ค็ดฐๅ‹•ๅ™จใฎๆ”พ้›ปใ‚’่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ้™ค็ดฐๅ‹•ๆ™‚ใฏใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ๅฐŽ้›ปๆ€งใฎ้ขใ‚„็‰ฉใซๆŽฅ่งฆใ•ใ›ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ๅฏ็‡ƒๆ€งใฎ็‰ฉใŒ่ฟ‘ใใซใ‚ใ‚‹็’ฐๅขƒใงใฏไฝฟใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚ไพ‹ใˆใฐ้™ค็ดฐๅ‹•ใฎ้š›ใชใฉใฏ้ซ˜ๆฟƒๅบฆ้…ธ็ด ใ‚’้ ใ–ใ‘ใฆใŠใๅฟ…่ฆใŒใ‚ใ‚Šใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ฟ‘ใใง้ซ˜ๆฟƒๅบฆ้…ธ็ด ใ‚’ไฝฟ็”จใ™ใ‚‹ๅ ดๅˆใฏใ€ๅฟ…ใšๆ›ๆฐ—ใ‚’ใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒดไฝ“ใฏใ€ๅธธใซไนพ็‡ฅใ—ใŸ็Šถๆ…‹ใซใ—ใฆใŠใ„ใฆใใ ใ•ใ„ใ€‚

โ€“ ้™ค็ดฐๅ‹•ใฎๅ‰ใซใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ๅ‘จ่พบๆธฉๅบฆใซ้ †ๅฟœใ•ใ›ใฆใใ ใ•ใ„ใ€‚ๆ€ฅๆฟ€ใชๆธฉๅบฆๅค‰ๅŒ–ใง้›ปๅญ้ƒจๅ“ใซ็ต้œฒใŒ็”Ÿใ˜ใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใ€ใ“ใ‚Œใซใ‚ˆใ‚Šๆ„Ÿ้›ปใฎๅฑ้™บใŒ็™บ็”Ÿใ™ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ ไบบไฝ“็”จใฎ้™ค็ดฐๅ‹•ใƒ‘ใƒƒใƒ‰ใ‚„ๅฐŽ้›ปใ‚ธใ‚งใƒซใฏไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ้™ค็ดฐๅ‹•ๆ™‚ใซ้™ค็ดฐๅ‹•ใƒ‘ใƒ‰ใƒซใ‚’ๅผทใๆŠผใ—ไป˜ใ‘ใ™ใŽใ‚‹ใจใ€ใ‚ขใƒผใ‚ฏๆ”พ้›ปใŒ่ตทใ“ใฃใŸใ‚Šใ€็ฉดใŒใ‚ใ„ใŸใ‚Šใ™ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ ่ƒดไฝ“ใ‚นใ‚ญใƒณใŒๆญฃใ—ใ่ฃ…็€ใ•ใ‚Œใฆใ„ใชใ„ๅ ดๅˆใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซ้™ค็ดฐๅ‹•ใ‚’่กŒใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

ๆฉŸๆขฐ็š„ใพใŸใฏ้›ปๆฐ—็š„ๅฑ้™บ ไปฅไธ‹ใฎๅ ดๅˆใฏใ€SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„๏ผš

โ€“ ไธŠๅŠ่บซใซๅ››่‚ขใŒๅ–ใ‚Šไป˜ใ‘ใ‚‰ใ‚Œใฆใ„ใชใ„ใ€‚

โ€“ ใ‚นใ‚ญใƒณใŒ็ ดใ‚Œใฆใ„ใ‚‹ใ€ใ‚ใ‚‹ใ„ใฏใƒ•ใ‚กใ‚นใƒŠใƒผใŒ้ฉๅˆ‡ใซ้–‰ใพใฃใฆใ„ใชใ„ใ€‚

โ€“ ๅ†…้ƒจใพใŸใฏๅค–้ƒจใฎใ‚ฑใƒผใƒ–ใƒซใ€ใƒใƒฅใƒผใƒ–ใ‚ใ‚‹ใ„ใฏใ‚ณใƒใ‚ฏใ‚ฟใŒ ็ ดๆใ—ใฆใ„ใ‚‹ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๅ†…ใพใŸใฏใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่กจ้ขใซๆถฒๆผใ‚ŒใŒใ‚ใ‚‹ใ€‚

โ€“ ็ฉบๆฐ—ๆผใ‚Œใ‚„ๆฉŸๆขฐๆๅ‚ทใ‚’็คบใ™ใ‚ˆใ†ใช็•ฐๅธธ้ŸณใŒใ‚ใ‚‹ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ็„กๅๅฟœใ‚„็•ฐๅธธใชใซใŠใ„/็…™ใชใฉใฎ้›ปๆฐ—ๆฉŸ่ƒฝ ้šœๅฎณใฎๅ…†ๅ€™ใŒใ‚ใ‚‹ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ไบˆๆœŸใ›ใฌไธๅ…ทๅˆใ‚„ๆ€ชๆˆ‘ใ‚’้˜ฒใใŸใ‚ใ€ๅค–้ƒจใ‚นใ‚ญใƒณใ‚’่ฃ…็€ใ›ใšใซ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

ใƒใƒƒใƒ†ใƒชใฎไฝฟ็”จใŠใ‚ˆใณใƒกใƒณใƒ†ใƒŠใƒณใ‚น

โ€“ SimJuniorใ€Link Boxใ€SimPad ใฎ้›ปๆบ็”จใซใฏ็ด”ๆญฃใฎใƒใƒƒใƒ†ใƒชใ‚’ๅฟ…ใšไฝฟ็”จใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ใƒใƒƒใƒ†ใƒชใฏๅฟ…ใš้ฉๅˆ‡ใซๅ–ใ‚Šไป˜ใ‘ใ‚‹ใ‚ˆใ†ใซใ—ใฆใใ ใ•ใ„ใ€‚ใƒใƒƒใƒ†ใƒช ใ‚’่ชคใฃใฆๆŒฟๅ…ฅใ—ใŸใ‚Šใ€ๆŽฅ็ถšใ—ใŸใ‚Šใ™ใ‚‹ใจใ€ใ‚ทใƒงใƒผใƒˆใ™ใ‚‹ใŠใใ‚ŒใŒใ‚ใ‚Šใพใ™ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ๅœฐๅŸŸใฎ่ฆๅˆถใซๅพ“ใฃใฆใƒใƒƒใƒ†ใƒชใ‚’ๅปƒๆฃ„ใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ๅค–้ƒจใƒใƒƒใƒ†ใƒชๅ……้›ปๅ™จใฏใ€ๅฑ‹ๅค–ใงไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชใฏใ€0ยฐC๏ฝž40ยฐC ๆธฉๅบฆ็ฏ„ๅ›ฒใงใฎใฟๅ……้›ป ใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ใƒใƒƒใƒ†ใƒชใฎๅ–ๆ‰ฑใ„ใ‚’่ชคใฃใŸใ‚Šใ€ๅˆ†่งฃใ—ใŸใ‚Šใ€ไฟฎ็†ใ‚’่ฉฆใฟใŸใ‚Šใ—ใชใ„ใงใใ ใ•ใ„ใ€‚ใƒใƒƒใƒ†ใƒชใŒ็›ฎใซ่ฆ‹ใˆใฆๆๅ‚ทใ‚’ๅ—ใ‘ใฆใ„ใ‚‹ใ€ ๆญฃๅธธใซๅ‹•ไฝœใ—ใชใ„ใ€ๆผใ‚Œใฆใ„ใ‚‹ใ‚ˆใ†ใซ่ฆ‹ใˆใ‚‹ๅ ดๅˆใฏใ€ใใฎใƒใƒƒใƒ†ใƒชใ‚’ไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ้›ปๆฐ—ใŒๆตใ‚Œใฆใ„ใ‚‹ใ€็†ฑใใชใฃใฆใ„ใ‚‹ใ€ใพใŸใฏ็…™ใŒๅ‡บใฆใ„ใ‚‹้ƒจๅˆ†ใซ็›ดๆŽฅ่งฆใ‚Œใชใ„ใ‚ˆใ†ใซใ€็ดฐๅฟƒใฎๆณจๆ„ใ‚’ๆ‰•ใฃใฆใใ ใ•ใ„ใ€‚ใƒใƒƒใƒ†ใƒช ใซๆถฒๆผใ‚ŒใŒใ‚ใ‚‹ๅ ดๅˆใ€ใƒใƒƒใƒ†ใƒชใ‚’ๅค–ใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ไธญใฎๆถฒไฝ“ใซๆ™’ใ•ใ‚Œใ‚‹ใจ็ˆ†็™บใฎๅฑ้™บใŒใ‚ใ‚Šใพใ™ใ€‚

โ€“ 30 ๅ›žใฎๅ……้›ปใ‚ตใ‚คใ‚ฏใƒซใ”ใจใซใ€ไธ€ๆ—ฆใƒใƒƒใƒ†ใƒชใ‚’ๅฎŒๅ…จใซไฝฟใ„ๅˆ‡ใฃใฆใใ ใ•ใ„ใ€‚ใƒใƒƒใƒ†ใƒชใ‚’ไฝฟใ„ๅˆ‡ใ‚‹ใซใฏใ€่‡ชๅ‹•็š„ใซใ‚ทใƒฃใƒƒใƒˆใƒ€ใ‚ฆใƒณใ•ใ‚Œใ‚‹ใพใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชใ‚’ใ‚ชใƒณใซใ—ใฆใŠใใพใ™ใ€‚

โ€“ ใƒใƒƒใƒ†ใƒชใ‚’ๆ–ฐใ—ใไบคๆ›ใ™ใ‚‹้š›ใฏใ€ๅฟ…ใšใƒฌใƒผใƒซใƒ€ใƒซ SimJunior ใƒใƒƒใƒ†ใƒชใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

ไฟ็ฎกใจ่ผธ้€

โ€“ ใƒ•ใƒซๅ……้›ปใ—ใŸใƒใƒƒใƒ†ใƒชใƒผใ‚’๏ผ‘ใƒถๆœˆไปฅไธŠไฟ็ฎกใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซๅ…ฅใ‚ŒใŸใพใพ่ˆช็ฉบ่ผธ้€ ใงใใพใ™ใ€‚

โ€“ ใƒใƒƒใƒ†ใƒชใ‚’ๅ˜ไฝ“ใง่ผธ้€ใ™ใ‚‹้š›ใฏใ€่ˆช็ฉบไผš็คพใพใŸใฏ่ฒจ็‰ฉไผš็คพใซ ้€ฃ็ตกใ—ใ€ๆœ€ๆ–ฐใฎ่ผธ้€่ฆๅ‰‡ใ‚’ใ”็ขบ่ชใใ ใ•ใ„ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใŠใ‚ˆใณใ‚ขใ‚ฏใ‚ปใ‚ตใƒชใฏใ€ใ‚ใ‚‹็จ‹ๅบฆ้‡้‡ใŒใ‚ใ‚Šใพใ™ใ€‚่ผธ้€ไธญใซ SimJunior ใŒใ—ใฃใ‹ใ‚Šใจๅ›บๅฎšใ•ใ‚Œใฆใ„ใ‚‹ใ“ใจใ‚’ๅธธใซ็ขบ่ชใ—ใ€ๆ€ชๆˆ‘ใ‚„่ฃฝๅ“ใธใฎๆๅ‚ทใ‚’้˜ฒใใ‚ˆใ†ใซไฟ็ฎกใ—ใฆใใ ใ•ใ„ใ€‚

ใฏใ˜ใ‚ใซ

Page 183: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

181

IO ใƒฌใƒƒใ‚ฐ

IO ใƒฌใƒƒใ‚ฐๆณจๆฐดๅฃ

SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟ

ECG ใ‚ณใƒใ‚ฏใ‚ฟ (RA)

้™ค็ดฐๅ‹•็ซฏๅญ (Sternum)

IV ใ‚ขใƒผใƒ 

ECG ใ‚ณใƒใ‚ฏใ‚ฟ (RL)

้›ปๆบใ‚ฑใƒผใƒ–ใƒซ

ๅค–้ƒจ็ฉบๆฐ—ๆŽฅ็ถš

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚ฑใƒผใƒ–ใƒซ (60 pin)

ECG ใ‚ณใƒใ‚ฏใ‚ฟ (LA)

่ก€ๅœงใ‚ขใƒผใƒ 

้™ค็ดฐๅ‹•็ซฏๅญ (Apex)

ECG ใ‚ณใƒใ‚ฏใ‚ฟ (LL)

ใฏใ˜ใ‚ใซ

Page 184: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

182

SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟ SimJunior ใซใ‚ˆใ‚Šใ‚คใƒณใ‚ฟใƒฉใ‚ฏใƒ†ใ‚ฃใƒ–ใชๆ•‘ๅ‘ฝใ‚นใ‚ญใƒซใฎใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใŒๅฎนๆ˜“ใซใชใ‚Šใพใ™ใ€‚ใพใŸใ€ใ“ใฎ่ฃฝๅ“ใงใฏใ€ๆ‚ฃ่€…ๅฏพๅฟœใ‚„่จบๆ–ญใ‚’ๅŠนๆžœ็š„ใซใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใ™ใ‚‹ใŸใ‚ใฎไบ‹ๅ‰ใซใƒ—ใƒญใ‚ฐใƒฉใƒ ใ•ใ‚ŒใŸใ‚ทใƒŠใƒชใ‚ชใ‚’ไฝฟ็”จ ใ™ใ‚‹ใ“ใจใŒใงใใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฏๅ—่ฌ›่€…ใซใ‚ˆใ‚‹ไป‹ๅ…ฅใ‚„ใ€ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผใซใ‚ˆใ‚‹ๅˆถๅพกใซๅๅฟœใ—ใพใ™ใ€‚

่‡ช็™บๅ‘ผๅธใ€ๆฐ—้“็ฎก็†ใ€ๅฃฐใ€้Ÿณใ€ๅฟƒ้›ปๅ›ณใŠใ‚ˆใณใใฎไป–ใฎ่‡จๅบŠ็š„ใช็‰นๅพดใ‚’ๆŒใค SimJunior ใฏใ€ๆฉŸ่ƒฝใ‚’็ถฒ็พ…ใ—ใŸๅฐๅ…ๆ‚ฃ่€…ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใงใ™ใ€‚ SimJuniorใงใฏใ€ใปใจใ‚“ใฉใฎใƒใ‚คใ‚ฟใƒซใ‚ตใ‚คใƒณใ‚’่ฆณๅฏŸใ—ใ€่ช่ญ˜ใงใใ€ ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผใฏใƒชใ‚ขใƒซใช่‡จๅบŠ็š„็ŠถๆณใซๅŸบใฅใๅ—่ฌ›่€…ใฎใ‚นใ‚ญใƒซใ‚’่ฉ•ไพกใงใใพใ™ใ€‚

SimJunior ใฎๆฉŸ่ƒฝ

โ€“ ใƒ‡ใ‚ฃใƒ•ใ‚ฃใ‚ซใƒซใƒˆใ‚จใ‚ขใ‚ฆใ‚งใ‚คใƒžใƒใ‚ธใƒกใƒณใƒˆใ€็ตŒๅฃใƒป็ตŒ้ผปๆŒฟ็ฎกใซ ๅฏพๅฟœใ—ใŸใƒชใ‚ขใƒซใชๆฐ—้“

โ€“ ๅ‘ผๅธใฎ่ฆณๅฏŸใŒๅฏ่ƒฝ

โ€“ ้™ค็ดฐๅ‹•ใŠใ‚ˆใณใ‚ซใƒซใƒ‡ใ‚ฃใ‚ชใƒใƒผใ‚ธใƒงใƒณใชใฉใฎๅพช็’ฐ้–ข้€ฃๆฉŸ่ƒฝ

โ€“ ไบคๆ›ๅฏ่ƒฝใช็žณๅญ” (ๆญฃๅธธใƒปๆ•ฃๅคงใƒปๅŽ็ธฎ)

โ€“ ็—™ๆ”ฃใฎใ‚ทใƒŸใƒฅใƒฌใƒผใƒˆ

โ€“ ่ƒธ้ชจๅœง่ฟซ

โ€“ ่ก€็ฎก็ขบไฟ

โ€“ ๆญฃๅธธใพใŸใฏ็•ฐๅธธใชๅฟƒ้Ÿณใƒปๅ‘ผๅธ้Ÿณใƒป่…ธ้Ÿณ

โ€“ ใƒ—ใƒญใ‚ฐใƒฉใƒ ๆธˆใฟใ‹ใคๆคœ่จผๆธˆใฎๆ‚ฃ่€…ใ‚ทใƒŠใƒชใ‚ชใซๅŸบใฅใใ‚ชใƒผใƒˆใƒขใƒผใƒ‰ ใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณ

SimPad ใพใŸใฏ LLEAP (PC) ใฎใ‚ทใƒŠใƒชใ‚ชใ‚’ไฝฟใฃใฆใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚’ๅฎŸๆ–ฝใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚ๆ‚ฃ่€…ใฎๅฎนๆ…‹ใฎๅค‰ๅŒ–ใฏไบ‹ๅ‰ใซใƒ—ใƒญใ‚ฐใƒฉใƒŸใƒณใ‚ฐใ•ใ‚ŒใฆใŠใ‚Šใ€ๅ—่ฌ›่€…ใฎไป‹ๅ…ฅใซๅฟœใ˜ใฆ่‡ชๅ‹•็š„ใซๅๅฟœใ—ใพใ™ใ€‚

ใƒžใƒใ‚ญใƒณๅฏธๆณ• ้•ทใ•/ๅน… (ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆœฌไฝ“)๏ผš120 cm x 42.5 cm้‡้‡ (ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆœฌไฝ“)๏ผš11.36 kg

SimJunior ่กฃๆœ

SimJunior ใฏใ€่„ฑใŒใ›ใ‚„ใ™ใ„ใ‚ˆใ†ใซใƒžใ‚ธใƒƒใ‚ฏใƒ†ใƒผใƒ—ใง้–‹ใ่กฃๆœใŒไป˜ๅฑžใ—ใฆใ„ใพใ™ใ€‚ๆด—ๆฟฏ่กจ็คบใฏ่กฃๆœใฎใ‚ฟใ‚ฐใซ่จ˜่ผ‰ใ•ใ‚Œใฆใ„ใพใ™ใ€‚

โ€“ ใ‚ทใƒฃใƒ„

โ€“ ใ‚ทใƒงใƒผใƒ„

โ€“ ใƒœใ‚ฏใ‚ตใƒผใ‚ทใƒงใƒผใƒ„

่‡จๅบŠ็š„ๆฉŸ่ƒฝใฎๆฆ‚่ฆ ๆฐ—้“ใฎๆฉŸ่ƒฝ ๆฐ—้“ใฏๆฐ—็ฎกไธปๅˆ†ๅฒใพใง่งฃๅ‰–ๅญฆ็š„ใซๆญฃ็ขบใชๆง‹้€ ใงใ™ใ€‚ไธ‹่จ˜ใฎๆ‰‹ๆŠ€ใŒใงใใพใ™๏ผš

โ€“ ้ ญ้ƒจๅพŒๅฑˆใ‚ใ”ๅ…ˆๆŒ™ไธŠ

โ€“ ไธ‹้กŽๆŒ™ไธŠ

โ€“ ่ผช็Šถ่ปŸ้ชจๅœง่ฟซ

โ€“ ๅธๅผ• (ๅฃ่…”ใŠใ‚ˆใณ้ผปๅ’ฝ้ ญ)

ใฏใ˜ใ‚ใซ

็ทŠๆ€ฅๅบฆใซๅฟœใ˜ใŸ่ค‡ๆ•ฐใฎๆ‰‹ๆฎตใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆ›ๆฐ—ใ‚’่กŒใ†ใ“ใจใŒใงใใพใ™ใ€‚

โ€“ ใƒใƒƒใ‚ฐใƒžใ‚นใ‚ฏๆ›ๆฐ—

โ€“ ็ตŒๅฃๆฐ—็ฎกๆŒฟ็ฎก

โ€“ ็ตŒ้ผปๆฐ—็ฎกๆŒฟ็ฎก

ๆฐ—้“็ขบไฟ็”จใฎใƒ‡ใƒใ‚คใ‚นใ‚’ไฝฟ็”จใ™ใ‚‹ๅ‰ใซใ€ใƒฌใƒผใƒซใƒ€ใƒซ็ด”ๆญฃใฎๆฝคๆป‘ใ‚นใƒ—ใƒฌใƒผใ‚’ๅก—ๅธƒใ—ใฆใใ ใ•ใ„ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆฐ—้“ใ‚’็ขบไฟใ™ใ‚‹ไธŠใง้ฉๅˆ‡ใชใƒ‡ใƒใ‚คใ‚นใจๆ–นๆณ•ใฏไปฅไธ‹ใฎใจใŠใ‚Šใงใ™๏ผš

โ€“ ใƒฉใƒชใƒณใ‚ฒใƒซใƒžใ‚นใ‚ฏ (ใ‚ตใ‚คใ‚บ #2.5)

โ€“ ๆฐ—็ฎกใƒใƒฅใƒผใƒ– (ใ‚ตใ‚คใ‚บ๏ผš4.5 ใ‚ซใƒ•ไป˜ใใ€5.5 ใ‚ซใƒ•ใชใ—)

ใ‚นใ‚ฟใ‚คใƒฌใƒƒใƒˆใฎไฝฟ็”จใ‚’ใŠๅ‹งใ‚ใ—ใพใ™ใ€‚ๆฐ—็ฎกใƒใƒฅใƒผใƒ–ใฎๅ…ˆ็ซฏใ‹ใ‚‰ๅ‡บใชใ„ใ‚ˆใ†ใซใ—ใฆใใ ใ•ใ„ใ€‚

ๆฐ—็ฎกใƒใƒฅใƒผใƒ–ใฎไฝ็ฝฎใซ่ชคใ‚ŠใŒใ‚ใ‚‹ใจใ€ใใ‚Œใซๅฟœใ˜ใŸ็Šถๆ…‹ใŒๅ†็พ ใ•ใ‚Œใพใ™๏ผš

โ€“ ๅณไธปๆฐ—็ฎกๆŒฟ็ฎก - ็‰‡ๅดใ ใ‘่ƒธ้ƒจใŒไธŠๆ˜‡

โ€“ ่ƒƒ่†จๆบ€

โ€“ ่ƒธ้ƒจ้Ÿณใฎๆถˆๅคฑ (ๅ‘ผๅธใซใคใ„ใฆใฎ็ซ ใ‚’ๅ‚็…ง)

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆฉŸ่ƒฝใฏใ€ไปฅไธ‹ใฎใ‚ˆใ†ใชใ•ใพใ–ใพใชๆฐ—้“ใ‚ทใƒŠใƒชใ‚ชใ‚’็คบใ™ใ‚ˆใ†ใซ่จญๅฎšใงใใพใ™๏ผš

โ€“ ่ˆŒๆตฎ่…ซ - ใชใ—ใ€ไธญ็จ‹ๅบฆใ€ๆœ€ๅคง

โ€“ ๆฐ—้“ใฎ้–‹้€š/้–‰ๅกž

ๅ‘ผๅธๆฉŸ่ƒฝ SimJunior ใงใฏใ€่‡ช็™บๅ‘ผๅธใซใ‚ˆใ‚‹่ƒธ้ƒญใฎไธŠไธ‹ใ€ใŠใ‚ˆใณๅ‘ผๅธๆ•ฐใฎๅค‰ๅŒ–ใ‚’ใ‚ทใƒŸใƒฅใƒฌใƒผใƒˆใงใใพใ™ใ€‚่ƒธ้ƒญใฎไธŠไธ‹ใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅณๅคช่…ฟใซ็ต„ใฟ่พผใพใ‚ŒใŸใ‚จใ‚ขใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใซใ‚ˆใ‚Š็”Ÿๆˆใ•ใ‚Œใพใ™ใ€‚

โ€“ ่‡ช็™บๅ‘ผๅธใงใฎไธก่ƒธ้ƒจใฎไธŠไธ‹

โ€“ ็‰‡่‚บๆŒฟ็ฎกใซใ‚ˆใ‚‹ๆ›ๆฐ—ๆ™‚ใฎ็‰‡ๅดใฎ่ƒธ้ƒจไธŠไธ‹

โ€“ ็‰‡ๅดใŠใ‚ˆใณไธกๅดใฎ่‚บ้Ÿณ

โ€“ ๆญฃๅธธใŠใ‚ˆใณ็•ฐๅธธใชๅ‘ผๅธ้Ÿณ

โ€“ ๅคšๆง˜ใชๅ‘ผๅธๆ•ฐ (0๏ฝž60 ๅ›ž/ๅˆ†)

โ€“ ๅ‰่ƒธ้ƒจใฎ่ด่จบ (4)

ใพใŸๅฎŒๅ…จใชๆฐ—้“้–‰ๅกžใ‚’ใ‚ทใƒŸใƒฅใƒฌใƒผใƒˆใ™ใ‚‹ใŸใ‚ใซใ€ๅทฆๅดใฎ่‚บใจๅณๅดใฎ่‚บใ‚’ๅˆฅใ€…ใซใ€ใพใŸใฏไธกๆ–นใ‚’ไธ€ๅบฆใซ้–‰ใ˜ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฏใ€่ฃœๅŠฉๆ›ๆฐ—ใจใจใ‚‚ใซไฝฟ็”จใ™ใ‚‹ใ“ใจใ‚‚ใงใใพใ™ใ€‚

ๆณจ๏ผš่‚บใฏ PEEP ใƒใƒซใƒ–ใงใฎไฝฟ็”จใ‚’ๆƒณๅฎšใ—ใฆใ„ใพใ›ใ‚“ใ€‚

Page 185: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

183

ๅพช็’ฐๆฉŸ่ƒฝ

ๅพช็’ฐ๏ผš

โ€“ ่ฑŠๅฏŒใชๅฟƒ้›ปๅ›ณใƒฉใ‚คใƒ–ใƒฉใƒชใ€่„ˆๆ‹ใฏ 0๏ฝž200 ใพใง่จญๅฎšๅฏ่ƒฝ

โ€“ ๅฟƒ้Ÿณ - ๅ‰่ƒธ้ƒจ (1)

โ€“ ECG ใƒขใƒ‹ใ‚ฟใƒชใƒณใ‚ฐ (4 ใ‚ณใƒใ‚ฏใ‚ฟใ€3 ใƒชใƒผใƒ‰ๅฟƒ้›ปๅ›ณ)

โ€“ 12 ใƒชใƒผใƒ‰ ECG ่กจ็คบ (LLEAP ไฝฟ็”จๆ™‚ใฎใฟ)

โ€“ ใƒšใƒผใ‚ทใƒณใ‚ฐ

โ€“ ่‡จๅบŠ็”จใฎ้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใ—ใŸ้™ค็ดฐๅ‹•ใŠใ‚ˆใณใ‚ซใƒซใƒ‡ใ‚ฃใ‚ชใƒใƒผใ‚ธใƒงใƒณ

้™ค็ดฐๅ‹•๏ผš

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณๆ‚ฃ่€…็—‡ไพ‹ใ”ใจใซใ€่‡ชๅ‹•ๅค‰ๆ›ใซๅฟ…่ฆใชใ‚ทใƒงใƒƒใ‚ฏๆ•ฐใŒ่จญๅฎšใ•ใ‚Œใพใ™ใ€‚

้™ค็ดฐๅ‹•็ซฏๅญ๏ผš

3 ใƒชใƒผใƒ‰ ECG๏ผš

่ก€ๅœงใŠใ‚ˆใณ่„ˆๆ‹๏ผš

โ€“ ่ก€ๅœงใฏใ‚ณใƒญใƒˆใ‚ณใƒ•้Ÿณใฎ่ด่จบใ‚’่กŒใ„ๆ‰‹ๅ‹•ๆธฌๅฎšใงใใพใ™ใ€‚

โ€“ ไธกๅด้ ธๅ‹•่„ˆใฎ่งฆ่จบใ€‚

โ€“ ไธป่ฆใช่„ˆๆ‹ใฏใ€ๆญฃๅธธใƒปๅผฑใ„ใƒปใชใ—ใ€ใฎใ„ใšใ‚Œใ‹ใซ่จญๅฎšใงใใพใ™ใ€‚

โ€“ ๆฉˆ้ชจๅ‹•่„ˆ/ไธŠ่…•ใฎ่„ˆๆ‹ใ‚‚ใ€ๆญฃๅธธใƒปๅผฑใ„ใƒปใชใ—ใ€ใฎใ„ใšใ‚Œใ‹ใซ่จญๅฎšใงใใพใ™ใ€‚

โ€“ ๅฟƒ้›ปๅ›ณใจๅŒๆœŸใ—ใŸ้ ธๅ‹•่„ˆใ€ไธŠ่…•ใ€ๆฉˆ้ชจๅ‹•่„ˆใ€่„ˆๆ‹ใ€‚

โ€“ ่„ˆๆ‹ๅผทๅบฆใฏ่ก€ๅœงใซ้€ฃๅ‹•ใ€‚

โ€“ ่„ˆๆ‹ใŒ่งฆ่จบใ•ใ‚Œ่จ˜้Œฒใ•ใ‚Œใพใ™ใ€‚

CPR ๆฉŸ่ƒฝ

โ€“ 2010 ใ‚ฌใ‚คใƒ‰ใƒฉใ‚คใƒณใซๆบ–ๆ‹ ใ—ใฆใ„ใพใ™ใ€‚

โ€“ ่ƒธ้ชจๅœง่ฟซใซใ‚ˆใฃใฆใ€่งฆ่จบๅฏ่ƒฝใช่„ˆๆ‹ใ€่ก€ๅœงๆณขๅฝขใ€ใŠใ‚ˆใณ ECG ใ‚ขใƒผใƒใƒ•ใ‚กใ‚ฏใƒˆใŒ็™บ็”Ÿใ—ใพใ™ใ€‚

โ€“ ่ƒธ้ชจๅœง่ฟซใฎๆทฑใ•ใจ่ƒธ้ƒญๆŠตๆŠ—ใฏ่‡จๅบŠใซๅณใ—ใฆใ„ใพใ™ใ€‚

โ€“ ๅœง่ฟซใฎๆทฑๅบฆใจใƒ†ใƒณใƒใ‚’ๆคœๅ‡บใ—ใพใ™ใ€‚

่ก€็ฎกๆฉŸ่ƒฝ IV ็ขบไฟ๏ผš

ๅณ่…•ใจๅณๆ‰‹ใง IV ็ขบไฟใŒๅฏ่ƒฝใงใ™ใ€‚IV ใ‚ขใƒผใƒ ใฏไปฅไธ‹ใฎ้ƒจๅˆ†ใงใฎ้™่„ˆ่ทฏ็ขบไฟใ€็‚นๆปดใ€ๆ€ฅ้€Ÿ้™ๆณจใ‚’่กŒใชใˆใพใ™๏ผš

โ€“ ๅ‰่…•้ƒจใฎๆœซๆขข้™่„ˆ

โ€“ ่‚˜ๅ‰็ชฉใŠใ‚ˆใณๆ‰‹่ƒŒ

้ชจๅ†… (IO) ใ‚ขใ‚ฏใ‚ปใ‚น๏ผš

ไปฅไธ‹ใฎ IO ็ฉฟๅˆบใฎใ‚ขใ‚ฏใ‚ปใ‚นใ‚‚ๅฏ่ƒฝใงใ™๏ผš

โ€“ ่„›้ชจ็ฒ—้ข (ๅณ)

โ€“ ๅ†…ๆžœ

ๆณจ๏ผš SimJunior ใซใฏใ€็ญ‹่‚‰ๆณจๅฐ„ (IM) ใฎใงใใ‚‹้ƒจๅˆ†ใฏใ‚ใ‚Šใพใ›ใ‚“ใ€‚ ็ญ‹่‚‰ๆณจๅฐ„ใฏๅฎŸๆ–ฝใ—ใชใ„ใงใใ ใ•ใ„ใ€‚

SimJunior ใฎ้Ÿณๅฃฐ่จญๅฎš SimJunior ใฏใ€ๅฟƒ้Ÿณใ€่‚บ้Ÿณใ€่…ธ้Ÿณใฎ่ด่จบ็”จใซใ€่ค‡ๆ•ฐใฎ่ด่จบ็ฎ‡ๆ‰€ใŒใ‚ใ‚Šใพใ™ใ€‚ใพใŸ SimJunior ใงใฏใ€็™บๅฃฐใ‚‚่จญๅฎšใงใใพใ™ใ€‚

SimJunior ใฎ้Ÿณๅฃฐ่จญๅฎšใซ้–ขใ™ใ‚‹่ฉณ็ดฐใฏใ€SimPad ๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใพใŸใฏ LLEAP ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

ใฏใ˜ใ‚ใซ

Page 186: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

184

ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC

ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC ใฏใ€LLEAP ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใ‚’ไฝฟ็”จใ—ใฆใ‚ทใƒŸใƒฅ ใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒใ‚ทใƒงใƒณใ‚’็ฎก็†ใ—ใพใ™ใ€‚LLEAP ใŠใ‚ˆใณใใฎไป–ใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณ้–ข้€ฃใฎไพฟๅˆฉใชใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใซใฏใ€Laerdal Simulation Home ใ‹ใ‚‰ใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝใงใ™ใ€‚

ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใƒฉใ‚คใ‚ปใƒณใ‚น ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC ใฏใ€ไบ‹ๅ‰ใซใ‚ขใ‚ฏใƒ†ใ‚ฃใƒ™ใƒผใƒˆใ•ใ‚ŒใŸ LLEAP ็”จ ใƒฉใ‚คใ‚ปใƒณใ‚นใŒใ‚คใƒณใ‚นใƒˆใƒผใƒซใ•ใ‚ŒใŸ็Šถๆ…‹ใงๅ‡บ่ทใ•ใ‚Œใพใ™ใ€‚

ใ‚ณใƒณใƒ”ใƒฅใƒผใ‚ฟใฎใƒใƒผใƒ‰ใ‚ฆใ‚งใ‚ขใ‚’ๅค‰ๆ›ดใพใŸใฏๆ›ดๆ–ฐใ™ใ‚‹ใจ (ๆ–ฐใ—ใ„ใƒใƒผใƒ‰ ใƒ‰ใƒฉใ‚คใƒ–ใ‚„ใƒžใ‚ถใƒผใƒœใƒผใƒ‰็ญ‰)ใ€ใƒฉใ‚คใ‚ปใƒณใ‚นใŒ็„กๅŠนใซใชใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚ใƒฉใ‚คใ‚ปใƒณใ‚นใฎๅ†ใ‚ขใ‚ฏใƒ†ใ‚ฃใƒ™ใƒผใ‚ทใƒงใƒณใซใคใ„ใฆใฏใ€ใŠ่ฟ‘ใใฎ ใƒฌใƒผใƒซใƒ€ใƒซใ‚ตใƒใƒผใƒˆใซใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

Laerdal Simulation HomeLaerdal Simulation Home ใซใฏใ€LLEAP ใŠใ‚ˆใณใใฎไป–ๆ‚ฃ่€…ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใซ้–ข้€ฃใ™ใ‚‹ใƒฌใƒผใƒซใƒ€ใƒซใƒ—ใƒญใ‚ฐใƒฉใƒ ใŒใ‚ใ‚Šใ€ใใ‚Œใ‚‰ใ‚’่ตทๅ‹•ใ•ใ›ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚ใ•ใ‚‰ใซใ€ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซใ‚‚้–‹ใใ“ใจใŒใงใใพใ™ใ€‚Laerdal Simulation Home ใฏใ€Windows ใ‚นใ‚ฟใƒผใƒˆใƒกใƒ‹ใƒฅใƒผ (Windows 7) ๅ†…ใฎ Laerdal Medical ใƒ•ใ‚ฉใƒซใƒ€ๅ†…ใซใ‚ใ‚Šใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณ ใ‚ปใƒƒใ‚ทใƒงใƒณใงไฝฟ็”จใ•ใ‚Œใ‚‹ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใฏใ€ไปฅไธ‹ใฎใƒกใ‚คใƒณใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใซๅˆ†้กžใ•ใ‚Œใพใ™ใ€‚

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server ใพใŸใฏ Session Viewer

ใ•ใ‚‰ใซใ€SimDesigner ใจไป–ใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใ‚‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใฎ ่จญ่จˆใพใŸใฏๆบ–ๅ‚™ใซไฝฟ็”จใ—ใพใ™ใ€‚

LLEAPLaerdal Learning Application (LLEAP) ใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒ ใ‚ทใƒงใƒณใฎๅฎŸ่กŒใ€ใ‚ณใƒณใƒˆใƒญใƒผใƒซใ€็›ฃ่ฆ–ใ‚’ใ™ใ‚‹ใŸใ‚ใฎใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ็”จใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใงใ™ใ€‚LLEAP ใฏใ€ใ‚ชใƒผใƒˆใƒขใƒผใƒ‰ใพใŸใฏใƒžใƒ‹ใƒฅใ‚ขใƒซใƒขใƒผใƒ‰ใงๆ“ไฝœใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚ใƒ—ใƒญใ‚ฐใƒฉใƒ ๆธˆใฟใฎใ‚ทใƒŠใƒชใ‚ชใซใฏใ‚ชใƒผใƒˆใƒขใƒผใƒ‰ใ‚’ไฝฟ็”จใ—ใพใ™ใŒใ€ใƒžใƒ‹ใƒฅใ‚ขใƒซใƒขใƒผใƒ‰ใ‚’ไฝฟ็”จใ™ใ‚‹ใจใ€ ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒใ‚ทใƒงใƒณใ‚’ๅฎŒๅ…จใซๆ‰‹ๅ‹•ใงใ‚ณใƒณใƒˆใƒญใƒผใƒซใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚ใƒžใƒ‹ใƒฅใ‚ขใƒซใƒขใƒผใƒ‰ใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚’ๅฎŸ่กŒใ™ใ‚‹ใซใฏใ€้€šๅธธใ€่‡จๅบŠ็š„ใซ่‰ฏๅฅฝใชใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚’ไฝœๆˆใ™ใ‚‹ใŸใ‚ใซใ€ใ‚ใ‚‹็จ‹ๅบฆใฎๅŒปๅญฆ็š„ๅฐ‚้–€็Ÿฅ่ญ˜ใŒๅฟ…่ฆใงใ™ใ€‚

Voice Conference Application (VCA)VCA ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณไธญใซไฝฟ็”จใ•ใ‚Œใ‚‹ใ™ในใฆใฎ้Ÿณๅฃฐใ‚’ไผใˆใ‚‹ใฎใซๅฟ…่ฆใงใ™ใ€‚VCA ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใ‚’ไฝฟ็”จใ™ใ‚‹ใจใ€ ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผใฏใ€ใ‚ปใƒƒใ‚ทใƒงใƒณไธญใซใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟ็ตŒ็”ฑใงใ‚ณใƒŸใƒฅใƒ‹ใ‚ฑใƒผใ‚ทใƒงใƒณใ‚’ๅ–ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚ใ•ใ‚‰ใซ VCA ใ‚’ไฝฟ็”จใ™ใ‚‹ใจใ€ ใƒใƒƒใƒˆใƒฏใƒผใ‚ฏไธŠใฎๅˆฅใฎใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผใจใ‚‚ใ‚ณใƒŸใƒฅใƒ‹ใ‚ฑใƒผใ‚ทใƒงใƒณใ‚’ๅ–ใ‚‹ใ“ใจใŒใงใใ€ใพใŸใƒกใƒณใƒใƒผใฎใฟใŒ่ฉฑใ—ใŸใ‚Š่žใ„ใŸใ‚Šใ™ใ‚‹ใ“ใจใŒใงใใ‚‹ๅ€‹ๅˆฅใฎใƒใƒฃใƒณใƒใƒซใ‚’ไฝœๆˆใ™ใ‚‹ใ“ใจใ‚‚ใงใใพใ™ใ€‚

Patient Monitor

Patient Monitor ใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใงใฏใ€ไธ€่ˆฌ็š„ใชๆ‚ฃ่€…ใƒขใƒ‹ใ‚ฟใ‚’ๅ†็พใ—ใฆใ„ใพใ™ใ€‚็”ป้ขไธŠใฎใ‚ฟใƒƒใƒใƒกใƒ‹ใƒฅใƒผใ‚’ไฝฟ็”จใ—ใฆใ€ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ ใ ใ‘ใงใชใใ€ๅ—่ฌ›่€…ใ‚‚ใƒขใƒ‹ใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—ใ‚„ๆ“ไฝœใŒใงใใพใ™ใ€‚

Session Viewer ใŠใ‚ˆใณ SimView ServerSession Viewer ใŠใ‚ˆใณ SimView Server ใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณไธญใฎ ใƒ“ใƒ‡ใ‚ชใ‚ญใƒฃใƒ—ใƒใƒฃใจๆ‚ฃ่€…ใƒขใƒ‹ใ‚ฟใฎ็”ป้ขใ‚ญใƒฃใƒ—ใƒใƒฃใ‚’่จ˜้Œฒใ™ใ‚‹ใ‚ขใƒ—ใƒช ใ‚ฑใƒผใ‚ทใƒงใƒณใงใ€ใ•ใ‚‰ใซใ‚คใƒณใ‚ฟใƒผใƒ•ใ‚งใ‚คใ‚นใ‚’ไฝฟ็”จใ—ใฆใ‚ปใƒƒใ‚ทใƒงใƒณใฎใƒ‡ใ‚ฃใƒ–ใƒชใƒผใƒ•ใ‚ฃใƒณใ‚ฐใŒใงใใพใ™ใ€‚ใ‚ปใƒƒใ‚ทใƒงใƒณ็ต‚ไบ†ๅพŒใซใฏใ€LLEAP ใซ็”Ÿๆˆใ•ใ‚ŒใŸใƒญใ‚ฐใƒ•ใ‚กใ‚คใƒซใŒ่ปข้€ใ•ใ‚Œใ€Session Viewer ใพใŸใฏ SimView Server ใฎใƒ“ใƒ‡ใ‚ชใƒ•ใ‚กใ‚คใƒซใจ็ตฑๅˆใ•ใ‚Œใ€ใƒ‡ใ‚ฃใƒ–ใƒชใƒผใƒ•ใ‚ฃใƒณใ‚ฐใ‚’่กŒใชใˆใพใ™ใ€‚

Session Viewer ใฏใ€้€šๅธธ LLEAP ใซไฝฟ็”จใ•ใ‚Œใฆใ„ใ‚‹ใ‚ณใƒณใƒ”ใƒฅใƒผใ‚ฟใจๅŒใ˜ใƒญใƒผใ‚ซใƒซไธŠใงๅฎŸ่กŒใ•ใ‚Œใ€SimView Server ใฏใ€ใƒญใƒผใ‚ซใƒซใƒใƒƒใƒˆ ใƒฏใƒผใ‚ฏใฎๅฐ‚็”จใ‚ตใƒผใƒไธŠใงๅฎŸ่กŒใ•ใ‚Œใพใ™ใ€‚LLEAP ใฎๅˆๅ›ž่ตทๅ‹•ๆ™‚ใซใ€ ใ‚ณใƒณใƒ”ใƒฅใƒผใ‚ฟใพใŸใฏใƒญใƒผใ‚ซใƒซใƒใƒƒใƒˆใƒฏใƒผใ‚ฏไธŠใงไฝฟ็”จๅฏ่ƒฝใชใƒ‡ใ‚ฃใƒ–ใƒชใƒผ ใƒ•ใ‚ฃใƒณใ‚ฐใ‚ทใ‚นใƒ†ใƒ ใ‚’้ธๆŠžใ™ใ‚‹ใ‚ˆใ†ๆฑ‚ใ‚ใ‚‰ใ‚Œใพใ™ใ€‚ใ“ใ‚ŒใฏๅพŒใงๅค‰ๆ›ด ใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚

ใใฎไป–ใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณไป–ใซใ‚‚ใ€ใƒ—ใƒญใ‚ฐใƒฉใƒ ใƒฉใ‚คใ‚ปใƒณใ‚นใ‚’ๅ‡ฆ็†ใ™ใ‚‹ License Managerใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒ•ใ‚กใƒผใƒ ใ‚ฆใ‚งใ‚ขใ‚’ๆ›ดๆ–ฐใ™ใ‚‹ใƒใƒƒใƒˆใƒฏใƒผใ‚ฏใซ้–ขใ™ใ‚‹ๅ•้กŒใ‚’่งฃๆฑบใ™ใ‚‹ Simulator Firmware & Network Fixer ใชใฉใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒใ‚ทใƒงใƒณใจไฝต็”จใงใใ‚‹ใƒ—ใƒญใ‚ฐใƒฉใƒ ใŒใ‚ใ‚Šใพใ™ใ€‚

SimDesignerSimDesigner ใฏใ€ใƒ—ใƒญใ‚ฐใƒฉใƒ ๆธˆใฟใฎ็‹ฌ่‡ชใ‚ทใƒŠใƒชใ‚ชใ‚’ไฝœๆˆใ™ใ‚‹ใŸใ‚ใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใงใ™ใ€‚ใ•ใ‚‰ใซใ€ใ‚ทใƒŠใƒชใ‚ชใฎใ‚ฐใƒฉใƒ•ใ‚ฃใƒƒใ‚ฏ่กจ็คบใ‚„ๅฐๅˆทใซใ‚‚ไฝฟ็”จใ™ใ‚‹ใ“ใจใŒใงใใพใ™ใ€‚

้ŽๅŽปใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใงไฝœๆˆใ•ใ‚ŒใŸใ‚ทใƒŠใƒชใ‚ชใ‚’ LLEAP ๅฏพๅฟœใƒ•ใ‚กใ‚คใƒซๅฝขๅผใซๅค‰ๆ›ใ™ใ‚‹ใซใฏใ€SimDesigner ใ‚’ใ‚คใƒณใ‚นใƒˆใƒผใƒซใ™ใ‚‹ๅฟ…่ฆใŒใ‚ใ‚Šใพใ™ใ€‚

ใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซLLEAP ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚จใ‚ขใŠใ‚ˆใณใใฎไป–ใฎใ‚ขใƒ—ใƒชใ‚ฑใƒผใ‚ทใƒงใƒณใซใคใ„ใฆใฎ่ฉณ็ดฐใฏใ€ไปฅไธ‹ใฎๆ‰‹้ †ใงใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

1. Windows ใฎ <้–‹ๅง‹> <ใ™ในใฆใฎใƒ—ใƒญใ‚ฐใƒฉใƒ > ใ‚’ใ‚ฏใƒชใƒƒใ‚ฏใ—ใพใ™ใ€‚

2. <Laerdal Simulation Home> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

3. <ใƒ˜ใƒซใƒ—> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

ใ‚ฆใ‚งใƒ–ใƒ€ใ‚ฆใƒณใƒญใƒผใƒ‰ๆœ€ๆ–ฐใฎๅ–ๆ‰ฑ่ชฌๆ˜Žๆ›ธใŠใ‚ˆใณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใฏใ€www.laerdal.com/downloads ใงใƒ€ใ‚ฆใƒณใƒญใƒผใƒ‰ใ—ใฆใใ ใ•ใ„ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

Page 187: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

185

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใฎๆบ–ๅ‚™ SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆบ–ๅ‚™ใŒๆ•ดใ„ใ€้–ข้€ฃใ™ใ‚‹ๅ‘จ่พบๆฉŸๅ™จ (SimPad ใพใŸใฏใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC ใŠใ‚ˆใณๆ‚ฃ่€…ใƒขใƒ‹ใ‚ฟ) ใฎ่จญๅฎšใŒ็ต‚ใ‚ใฃใŸๅพŒใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณๅฎŸๆ–ฝใฎๅ‰ใซใ€ๅนพใคใ‹ๆœ€ๅพŒใฎๆบ–ๅ‚™ใ‚’ๅฟ…่ฆใจใ™ใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚

ๆœ€ๅพŒใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใฎๆบ–ๅ‚™ใซใฏใ€ไปฅไธ‹ใฎไฝœๆฅญใŒๅซใพใ‚Œใพใ™ใ€‚

โ€ข IO ใƒฌใƒƒใ‚ฐใฎๆบ–ๅ‚™

โ€ข IV ใฎๆŽฅ็ถš

โ€ข ไฝ™ๅˆ†ใช IV ๆถฒๆŽ’ๅ‡บใฎๆบ–ๅ‚™

โ€ข IV ใ‚ขใƒผใƒ ใฎใ‚ฏใƒชใƒผใƒ‹ใƒณใ‚ฐ

โ€ข ้™ค็ดฐๅ‹•ใƒ—ใƒฌใƒผใƒˆใฎๅ–ใ‚Šไป˜ใ‘

โ€ข ่ก€ๅœง่จˆใ‚ซใƒ•ใฎๆŽฅ็ถš

โ€ข ็žณๅญ”ใฎไบคๆ›

โ€ข ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใฎๆŽฅ็ถš

โ€ข ๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใฎ่จญๅฎšใฎๅค‰ๆ›ด

IO ใƒฌใƒƒใ‚ฐใฎๆบ–ๅ‚™ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅณ่„šใฏใ€้ชจ้ซ„็ฉฟๅˆบใฎ็ทด็ฟ’็”จใซ่จญ่จˆใ•ใ‚Œใฆใ„ใพใ™ใ€‚ ๅณ่„šใฎๆง‹้€ ใซใฏใ€่†ใ€่„›้ชจใ€่„›้ชจ็ฒ—้ขใ€ใŠใ‚ˆใณๅ†…ๆžœใŒๅซใพใ‚Œใพใ™ใ€‚ ๅณ่„šใซใฏใ€ใƒใƒฅใƒผใƒ–ใŠใ‚ˆใณๆณจๅ…ฅไธญใซๅฎนๅ™จใจใ—ใฆไฝฟ็”จใ™ใ‚‹ใŸใ‚ใฎ IV ใƒใƒƒใ‚ฐใŒ 1 ใคไป˜ใ„ใฆใ„ใพใ™ใ€‚

ไปฅไธ‹ใฎๅ™จๅ…ทใŒๅฟ…่ฆใงใ™๏ผš

โ€ข IV ใƒใƒƒใ‚ฐใŠใ‚ˆใณๆŠ•ไธŽใ‚ปใƒƒใƒˆ

โ€ข ๆ“ฌไผผ่ก€ๆถฒ

โ€ข 35 cc ใฎๆณจๅฐ„ๅ™จใŠใ‚ˆใณ 16 ใ‚ฒใƒผใ‚ธใฎ้ชจ้ซ„้‡

IO ใƒฌใƒƒใ‚ฐใธใฎๆถฒไฝ“ใฎๅ……ๅกซใŠใ‚ˆใณไฝฟ็”จๆบ–ๅ‚™๏ผš

1. ใƒฌใƒƒใ‚ฐใ‚’ๆŒใกไธŠใ’ใพใ™ใ€‚

2. ใ‹ใ‹ใจใซใ‚ใ‚‹ใƒ—ใƒฉใ‚ฐใ‚’้–‹ใ‘ใพใ™ใ€‚

3. ๆณจๅฐ„ๅ™จใ‚’ไฝฟใฃใฆใ€็ด„ 240๏ฝž250 cc ใฎๆ“ฌไผผ่ก€ๆถฒใง้ชจใ‚’ๆบ€ใŸใ—ใพใ™ใ€‚

4. IV ใƒชใ‚ถใƒผใƒใƒใƒƒใ‚ฐใซใƒใƒฅใƒผใƒ–ใ‚’ๆŽฅ็ถšใ—ใพใ™ใ€‚(ๅฟ…่ฆใซๅฟœใ˜ใ€ ใ‚ฏใƒฉใƒณใƒ—ใ‚’ไฝฟใฃใฆไธญใฎๅœงใ‚’่ชฟๆ•ดใ—ใฆใใ ใ•ใ„)

5. ๆ“ฌไผผ่ก€ๆถฒใŒๅธๅผ•็”จใซ้ชจๅ†…ใซๆฎ‹ใ‚‹ใ‚ˆใ†ใ€ใƒชใ‚ถใƒผใƒใƒใƒƒใ‚ฐใซใคใช ใŒใ‚‹ใƒใƒฅใƒผใƒ–ใ‚’้–‰ใ˜ใพใ™ใ€‚

6. ใƒชใ‚ถใƒผใƒใƒใƒƒใ‚ฐใŒไธ€ๆฏใซใชใฃใŸใ‚‰ๆณจๅ…ฅใ‚’ๅœๆญขใ—ใ€็ฉบใฎใƒใƒƒใ‚ฐใจไบคๆ›ใ—ใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ไฟ็ฎกใ™ใ‚‹ๅ‰ใซใ€ไปฅไธ‹ใ‚’่กŒใชใฃใฆใใ ใ•ใ„ใ€‚

โ€“ IV ใƒฉใ‚คใƒณใจใƒชใ‚ถใƒผใƒใƒใƒƒใ‚ฐใ‚’ใƒฌใƒƒใ‚ฐใ‹ใ‚‰ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

โ€“ ๆถฒไฝ“ใ‚’ใ™ในใฆๆŽ’ๅ‡บใ—ใพใ™ใ€‚

โ€“ ใƒฌใƒƒใ‚ฐใฏ็ฉบๆฐ—ไนพ็‡ฅใงใใ‚‹ใ‚ˆใ†ใซๅ–ใ‚Šๅค–ใ—ใฆไฟ็ฎกใ—ใพใ™ใ€‚

ๆณจ๏ผš็”Ÿ็†้ฃŸๅกฉๆฐดใชใฉใฏไฝฟ็”จใ—ใชใ„ใงใใ ใ•ใ„ใ€‚ใƒฌใƒƒใ‚ฐใฎๆๅ‚ทใฎๅŽŸๅ› ใจใชใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚ใƒŸใƒใƒฉใƒซๅˆ†ใฎ่“„็ฉใ‚’้ฟใ‘ใ‚‹ใŸใ‚ใ€่’ธ็•™ๆฐดใพใŸใฏ่„ฑใ‚คใ‚ชใƒณๆฐดใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

IV ๆถฒใฎๆŠ•ไธŽ IV ใ‚ขใƒผใƒ ใฏๅ‰่…•ๆœซๆขข้™่„ˆใ€่‚˜ๅ‰็ชฉใ€ๆ‰‹่ƒŒใ‹ใ‚‰ใฎ่–ฌๅ‰คๆŠ•ไธŽใ€้™่„ˆ่ทฏ ็ขบไฟใ€่ผธๆถฒใ€ๆ€ฅ้€Ÿ้™ๆณจ็”จใฎใƒˆใƒฌใƒผใƒ‹ใƒณใ‚ฐใ‚’ใ‚ตใƒใƒผใƒˆใ—ใพใ™ใ€‚

IV ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใซใฏใ€20๏ฝž22 ใ‚ฒใƒผใ‚ธใฎ้‡ใ‚’ไฝฟ็”จใ—ใพใ™ใ€‚้™่„ˆใฎ ่ฉฐใพใ‚Šใ‚’้˜ฒใใŸใ‚ใซใ€IV ่–ฌๅ‰คใฎใ‚ทใƒŸใƒฅใƒฌใƒผใƒˆใซใฏ่’ธ็•™ใพใŸใฏ่„ฑใ‚คใ‚ชใƒณ ๆฐดใฎใฟใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

Page 188: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

186

ไฝ™ๅ‰ฐ IV ๆถฒใฎๆŽ’ๅ‡บ IV ใ‚ขใƒผใƒ ใฏใ‚ชใƒผใƒ—ใƒณใ‚ทใ‚นใƒ†ใƒ ใงใ™ใ€‚่ผธๆถฒใชใฉใฎๆถฒไฝ“ใฏๆŠ•ไธŽใจๅŒๆ™‚ใซๆŽ’ๅ‡บใ•ใ‚Œใพใ™ใ€‚

ๅ„ใ‚ปใƒƒใ‚ทใƒงใƒณใฎๅ‰ใซไปฅไธ‹ใฎๆ‰‹้ †ใ‚’ๅฎŸ่กŒใ—ใฆใใ ใ•ใ„ใ€‚

1. IV ใ‚ชใƒผใƒใƒผใƒ•ใƒญใƒผใƒใƒฅใƒผใƒ– (ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅณ่…•ๅ†…) ใ‚’ใ‚ชใƒผใƒใƒผใƒ•ใƒญใƒผๅฎนๅ™จ (IV ใƒใƒƒใ‚ฐใชใฉ) ใซๅ–ใ‚Šไป˜ใ‘ใพใ™ใ€‚

2. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณไธญใ€ไฝ™ๅˆ†ใชๆถฒไฝ“ใŒๅฎนๅ™จใซๆŽ’ๅ‡บใ•ใ‚Œใ‚‹ใ‚ˆใ†ใซใ—ใพใ™ใ€‚

IV ใ‚ขใƒผใƒ ใฎใ‚ฏใƒชใƒผใƒ‹ใƒณใ‚ฐ ๅ„ใ‚ปใƒƒใ‚ทใƒงใƒณใฎๅพŒใ€ใพใŸใฏ 1 ๆ—ฅใฎไฝฟ็”จใฎๅพŒใงใ€IV ใ‚ขใƒผใƒ ใ‚’ 60% ใฎใ‚คใ‚ฝใƒ—ใƒญใƒ‘ใƒŽใƒผใƒซใพใŸใฏ 70% ใฎใ‚จใ‚ฟใƒŽใƒผใƒซใงๆด—ใ„ๆตใ—ใฆๆด—ๆต„ใ—ใฆใใ ใ•ใ„ใ€‚

้™ค็ดฐๅ‹•ใ‚ขใƒ€ใƒ—ใ‚ฟใƒ—ใƒฌใƒผใƒˆใฎๅ–ใ‚Šไป˜ใ‘ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟไธŠๅŠ่บซใซใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซใƒปใƒ•ใ‚ฃใƒชใƒƒใƒ—ใ‚น้™ค็ดฐๅ‹•ๅ™จ็”จใฎใ‚ณใƒใ‚ฏใ‚ฟใŒไบˆใ‚ๅ–ใ‚Šไป˜ใ‘ใ‚‰ใ‚Œใฆใ„ใพใ™ใ€‚ใƒ‘ใƒ‰ใƒซๅผ้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟใ†้š›ใฏใ€ใ“ใ‚Œใ‚’ไบคๆ›ใ™ใ‚‹ๅฟ…่ฆใŒใ‚ใ‚Šใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซใฏ 2 ใคใฎ้™ค็ดฐๅ‹•ใƒ—ใƒฌใƒผใƒˆใŒๅŒๆขฑใ•ใ‚Œใฆใ„ใพใ™ใ€‚้™ค็ดฐๅ‹•ใƒ‘ใƒ‰ใƒซไป˜ใฎ้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใ™ใ‚‹ๅ‰ใซใ€้™ค็ดฐๅ‹•ใƒ—ใƒฌใƒผใƒˆใ‚’ๅ–ใ‚Šไป˜ใ‘ใฆใŠใ„ใฆใใ ใ•ใ„ใ€‚ใƒ—ใƒฌใƒผใƒˆใฏๆ‰€ๅฎšใฎไฝ็ฝฎใซใ—ใฃใ‹ใ‚Šใจใƒใ‚ธใง็•™ใ‚ใพใ™ใ€‚

้™ค็ดฐๅ‹•ใฎๅฎŸๆ–ฝๆ™‚ SimJunior ใงใฏใ€่‡จๅบŠ็”จใฎ้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใงใใพใ™ใ€‚้™ค็ดฐๅ‹•ไธญใ€้™ค็ดฐ ๅ‹•ๅ™จใ‚„ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซ่งฆใ‚Œใ‚‹ใจๆ„Ÿ้›ปใ™ใ‚‹ๅฑ้™บๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใง้™ค็ดฐๅ‹•ๅ™จใ‚’ไฝฟ็”จใ™ใ‚‹้š›ใฏใ€ใ™ในใฆใฎๆจ™ๆบ–็š„ๅฎ‰ๅ…จๆŽช็ฝฎใ‚’่ฌ› ใ˜ใฆใใ ใ•ใ„ใ€‚

ๆณจๆ„๏ผš้™ค็ดฐๅ‹•ไธญใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’ๅฐŽ้›ป้ขใ‚„ๅฐŽ้›ปๆ€งใฎ็‰ฉใจๆŽฅ่งฆใ•ใ›ใชใ„ใงใใ ใ•ใ„ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ้™ค็ดฐๅ‹•ใฏใ€้™ค็ดฐๅ‹•ๅ™จใ‚ณใƒใ‚ฏใ‚ฟไธŠใงใฎใฟๅฎŸ่กŒใ—ใฆใใ ใ•ใ„ใ€‚

โ€“ ่ƒดไฝ“ใ‚นใ‚ญใƒณใŒใšใ‚Œใฆใ„ใ‚‹ๅ ดๅˆใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซ้™ค็ดฐๅ‹•ใ‚’่กŒ ใ‚ใชใ„ใงใใ ใ•ใ„ใ€‚

่ก€ๅœง่จˆใ‚ซใƒ•ใฎๆŽฅ็ถš ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซใฏใ€ๅฐ‚็”จใฎ่ก€ๅœงใ‚ซใƒ•ใŒๅŒๆขฑใ•ใ‚Œใฆใ„ใพใ™ใ€‚ไฝฟ็”จๅ‰ใซใ€ ใƒใƒฅใƒผใƒ–ใ‚’ Link Box ใฎๅด้ขใซใ‚ใ‚‹็™ฝ่‰ฒใฎ่ก€ๅœงใ‚ณใƒใ‚ฏใ‚ฟใซๆŽฅ็ถšใ—ใฆใใ ใ•ใ„ใ€‚

ๆณจ๏ผšใ‚ณใƒญใƒˆใ‚ณใƒ•้Ÿณๅ†็”Ÿ็”จใฎใ‚นใƒ”ใƒผใ‚ซใƒผใฏใ€ๅทฆ่…•ใฎ่‚˜ๅ‰็ชฉ (ไธ‹ๅ›ณ ใฎๅ††ใง็คบใ—ใŸ้ƒจๅˆ†) ใซใ‚ใ‚Šใพใ™ใ€‚ๆฉˆ้ชจๅ‹•่„ˆๆ‹ๅ‹•ใจไธŠ่…•ๆ‹ๅ‹•ใฏ ไธ‹ๅ›ณใฎๅ››่ง’ใงๅ›ฒใ‚“ใ ้ƒจๅˆ†ใง่งฆ็Ÿฅใงใใพใ™ใ€‚

LLEAP ใงใฎ่ก€ๅœง่จˆใ‚ซใƒ•ใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ

1. ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใƒ„ใƒผใƒซ> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

2. ใƒ„ใƒผใƒซใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

3. ใ‚ตใƒ–ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <่ก€ๅœง่จˆใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ> ใ‚’้ธๆŠž ใ—ใพใ™ใ€‚

4. ใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณใ‚’ๅฎŸ่กŒใ™ใ‚‹ใซใฏใ€็”ป้ขใ‚ฆใ‚คใ‚ถใƒผใƒ‰ใฎๆŒ‡็คบใซๅพ“ใ„ใพใ™ใ€‚

SimPad ใงใฎ่ก€ๅœง่จˆใ‚ซใƒ•ใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ

1. ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

2. ใƒ‰ใƒญใƒƒใƒ—ใƒ€ใ‚ฆใƒณใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <่ก€ๅœง่จˆใฎใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณ> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

3. ใ‚ญใƒฃใƒชใƒ–ใƒฌใƒผใ‚ทใƒงใƒณใ‚’ๅฎŸ่กŒใ™ใ‚‹ใซใฏใ€็”ป้ขใ‚ฆใ‚คใ‚ถใƒผใƒ‰ใฎๆŒ‡็คบใซๅพ“ใ„ใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

Page 189: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

187

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

็žณๅญ”ใฎไบคๆ› SimJunior ใฏๆญฃๅธธใช็žณๅญ”ใŒๅ–ใ‚Šไป˜ใ‘ใ‚‰ใ‚ŒใŸ็Šถๆ…‹ใง็ดๅ“ใ•ใ‚Œใพใ™ใ€‚ SimJunior ใซใฏใ€ไบคๆ›็”จใฎใƒ—ใƒฉใ‚นใƒใƒƒใ‚ฏ่ฃฝใฎ็žณๅญ” (ๆ•ฃๅคงใจๅŽ็ธฎ) ใŒๅ…ฅ ใฃใŸๅ€‹ๅˆฅใ‚ญใƒƒใƒˆใŒๅŒๆขฑใ•ใ‚Œใพใ™ใ€‚

็žณๅญ”ใ‚’ไบคๆ›ใ™ใ‚‹ใซใฏใ€ไปฅไธ‹ใฎๆ‰‹้ †ใ‚’ๅฎŸ่กŒใ—ใพใ™ใ€‚

1. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒ•ใ‚งใ‚คใ‚นใ‚นใ‚ญใƒณใ‚’็ ดใ‹ใชใ„ใ‚ˆใ†ใซๆณจๆ„ใ—ใชใŒใ‚‰ใ€ๆ…Ž้‡ใซใพใถใŸใ‚’ๅคงใใ้–‹ใใพใ™ใ€‚

2. ใ‚ญใƒƒใƒˆใซๅŒๆขฑใฎๅธ็€ใ‚ซใƒƒใƒ—ใƒ„ใƒผใƒซใ‚’ไฝฟใฃใฆใ€ใพใŸใฏ็ˆชใฎๅ…ˆใงใ€ ๆ…Ž้‡ใซ็›ฎใ‹ใ‚‰็žณๅญ”ใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

3. ๅธ็€ใ‚ซใƒƒใƒ—ใƒ„ใƒผใƒซใ‚’ไฝฟใ†ใ‹ใ€้ฉๆญฃใชไฝ็ฝฎใ‚’ใใฃใจๆŠผใ—ใฆ็žณๅญ”ใ‚’ ๅธŒๆœ›ใฎใ‚‚ใฎใจไบคๆ›ใ—ใพใ™ใ€‚

ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใฎไฝฟ็”จ ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใฏใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅณๅดใ‹ใ‚‰ๅ‡บใฆใ„ใ‚‹ใ‚ฑใƒผใƒ–ใƒซใฎๆŸใซใ‚ใ‚‹้€ๆ˜Žใชใƒใƒฅใƒผใƒ–ใซๆŽฅ็ถšใ—ใพใ™ใ€‚ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใ‚’ไฝฟ็”จใ—ใฆใ„ใ‚‹ๅ ดๅˆใฏใ€SimPad ใพใŸใฏ LLEAP ใฎ่จญๅฎšใงๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใ‚’ใ‚ชใƒ•ใซใ—ใพใ™ใ€‚

ๅค–้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŠใ‚ˆใณ SimJunior ใซๅฏพๅฟœใ™ใ‚‹ใƒฌใ‚ฎใƒฅใƒฌใƒผใ‚ฟใฎ่ฉณ็ดฐใซใคใ„ใฆใฏใ€ๆœ€ๅฏ„ใฎใƒฌใƒผใƒซใƒ€ใƒซ่ฒฉๅฃฒๆ‹…ๅฝ“่€…ใพใงใ”้€ฃ็ตกใใ ใ•ใ„ใ€‚

SimPad ใฎๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใ‚’ใ‚ชใƒณ/ใ‚ชใƒ•ใซใ™ใ‚‹

1. <ใƒžใƒ‹ใƒฅใ‚ขใƒซใƒขใƒผใƒ‰> ใ‚’่ตทๅ‹•ใ—ใ€ใƒ†ใƒผใƒžใ‚’้ธๆŠžใ—ใ€ใ‚ปใƒƒใ‚ทใƒงใƒณใ‚’้–‹ๅง‹ใ—ใพใ™ใ€‚

2. ไธ‹้ƒจใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใใฎไป–> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

3. ใ‚ตใƒ–ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ต> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

4. ใƒ€ใ‚คใ‚ขใƒญใ‚ฐใงๅธŒๆœ›ใ™ใ‚‹ๅค‰ๆ›ดใ‚’่กŒใฃใŸใ‚‰ใ€OK ใ‚’ใ‚ฏใƒชใƒƒใ‚ฏใ—ใพใ™ใ€‚

LLEAP ใงๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใ‚’ใ‚ชใƒณ/ใ‚ชใƒ•ใซใ™ใ‚‹

1. ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใƒ„ใƒผใƒซ> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

2. ใƒ„ใƒผใƒซใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—> ใ‚’้ธๆŠž ใ—ใพใ™ใ€‚

3. ใ‚ตใƒ–ใƒกใƒ‹ใƒฅใƒผใ‹ใ‚‰ <ๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ต> ใ‚’้ธๆŠžใ—ใพใ™ใ€‚

4. ใƒ€ใ‚คใ‚ขใƒญใ‚ฐใงๅธŒๆœ›ใ™ใ‚‹ๅค‰ๆ›ดใ‚’่กŒใฃใŸใ‚‰ใ€OK ใ‚’ใ‚ฏใƒชใƒƒใ‚ฏใ—ใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

Page 190: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

188

ๅ„ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ปใƒƒใ‚ทใƒงใƒณๅพŒใฎใƒกใƒณใƒ†ใƒŠใƒณใ‚น ไปฅไธ‹ใฏใ€SimJunior ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚’้•ทใใซใ‚ใŸใฃใฆไฝฟ็”จใงใใ‚‹ใ‚ˆใ†ใซใ™ใ‚‹ใŸใ‚ใซๅฟ…่ฆใชไบˆ้˜ฒ็ญ–ใงใ™ใ€‚

โ€“ SimPadใ€Link Box ใŠใ‚ˆใณ PC ใฎ้›ปๆบใ‚’ๅˆ‡ใ‚Šใพใ™

โ€“ ๅฟ…่ฆใซๅฟœใ˜ใฆใƒใƒƒใƒ†ใƒชใ‚’ๅ……้›ปใ—ใพใ™

โ€“ IV ใ‚ขใƒผใƒ ใ‚’ๆด—ๆต„ใ—ใ€IO ใƒฌใƒƒใ‚ฐใ‹ใ‚‰ๆถฒไฝ“ใ‚’ๆŠœใใพใ™ (IO ใƒฌใƒƒใ‚ฐ ้–‹ๅฃ้ƒจใฎไธ‹้ƒจใซใƒ—ใƒฉใ‚ฐใ‚’ๅทฎใ—่พผใ‚“ใ ใพใพ)

โ€“ IV ใ‚ขใƒผใƒ ใ‚’ไฝฟ็”จใ™ใ‚‹ๅ„ใ‚ปใƒƒใ‚ทใƒงใƒณๅพŒใซใ€60% ใ‚คใ‚ฝใƒ—ใƒญใƒ‘ใƒŽใƒผใƒซใ‚ขใƒซใ‚ณใƒผใƒซใพใŸใฏ 70% ใ‚จใ‚ฟใƒŽใƒผใƒซใง IV ใ‚ขใƒผใƒ ใ‚’ๆด—ใ„ๆตใ—ใพใ™

โ€“ ๆนฟใฃใŸๅธƒใงใ‚นใ‚ญใƒณใ‚’ๆ‹ญใใพใ™

โ€“ ๆนฟใฃใŸๅธƒใ‚„่กฃๆœใ‚’ๅค–ใ—ใพใ™

โ€“ ๆนฟใฃใŸๅธƒใ‚„ๆถˆๆฏ’็”จใ‚ขใƒซใ‚ณใƒผใƒซใงใƒ†ใƒผใƒ—ใฎๆฎ‹็•™็‰ฉใ‚’ๅ–ใ‚Š้™คใใพใ™

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎไฝฟ็”จๆณ•ใซๅŸบใฅใใ€ไฝฟ็”จๆธˆใฟใ€ใพใŸใฏๆๅ‚ทใฎใ‚ใ‚‹ใƒขใ‚ธใƒฅใƒผใƒซใ‚’ไบคๆ›ใ—ใพใ™

โ€“ ็›ฎใซ่ฆ‹ใˆใ‚‹ๆๅ‚ทใฎใ‚ใ‚‹ใ‚ฑใƒผใƒ–ใƒซใ€ใพใŸใฏใ‚ณใƒใ‚ฏใ‚ฟใ‚’ไบคๆ›ใ—ใพใ™

โ€“ ใƒžใƒใ‚ญใƒณใฎๆ•ดๅ‚™ใฏใ€ๅฎšๆœŸ็š„ใซ่กŒใฃใฆใใ ใ•ใ„

ไปฅไธ‹ใฎๅ ดๅˆใฏๅธธใซๆ•ดๅ‚™ใ‚’่กŒใฃใฆใใ ใ•ใ„๏ผš

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎไธญใ‚„่กจ้ขใซๆถฒไฝ“ใŒใ“ใผใ‚ŒใŸๅ ดๅˆ

โ€“ ใปใ“ใ‚Šใฃใฝใ„็’ฐๅขƒใงไฝฟ็”จใ—ใŸๅพŒ

ๆณจ๏ผšใ‚นใƒšใ‚ขใƒ‘ใƒผใƒ„ใฎๆƒ…ๅ ฑใซใคใ„ใฆใฏใ€ใ€Œๆถˆ่€—ๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒชใ€ ใฎ็ซ ใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

ไฟ็ฎกใŠใ‚ˆใณ็™บ้€ๆ™‚

โ€“ 60% ใฎใ‚คใ‚ฝใƒ—ใƒญใƒ‘ใƒŽใƒผใƒซ ใ‚ขใƒซใ‚ณใƒผใƒซใพใŸใฏ 70% ใฎใ‚จใ‚ฟใƒŽใƒผใƒซใง IV ใ‚ขใƒผใƒ ใ‚’ๆด—ใ„ใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅณ่ถณใฎๅบ•ใซใ‚ใ‚‹ๆŽ’ๆถฒใƒใƒซใƒ– ใ‚’้–‹ใใพใ™ใ€‚

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

Page 191: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

189

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ไธŠๅŠ่บซใ‚’้–‹ใ

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒดไฝ“ใ‚’้–‹ใใจใ€ไปฅไธ‹ใ‚’ๅฎŸ่กŒใงใใพใ™๏ผš

โ€“ ๅ››่‚ขใฎๅ–ใ‚Šไป˜ใ‘ใจไบคๆ›

โ€“ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชไบคๆ›

โ€“ ๅ‘ผๅธใƒใƒซใƒผใƒณใŠใ‚ˆใณ่‚บใฎไบคๆ›

โ€“ ่ƒดไฝ“ใ‚นใ‚ญใƒณใฎไบคๆ›

โ€“ ็ฐกๅ˜ใช็‚นๆคœ

่ญฆๅ‘Š๏ผš่ƒดไฝ“ใฏๅทฆใ‹ใ‚‰ๅณใธใ€ใ‚นใ‚ญใƒณใฎใƒ›ใƒƒใ‚ฏใ‚’ใใฃใจๅค–ใ—ใฆ้–‹ ใใพใ™ใ€‚่ƒดไฝ“ใฎใ‚นใ‚ญใƒณใฏไนฑๆšดใซๅผ•ใไธŠใ’ใชใ„ใงใใ ใ•ใ„ใ€‚็น‹ใŒใฃใฆใ„ใ‚‹ใ‚ฑใƒผใƒ–ใƒซใŒๆๅ‚ทใ™ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚

1. ่ƒดไฝ“ใฎๅทฆๅดใŠใ‚ˆใณไธก่‚ฉใซใ‚ใ‚‹ใ‚นใ‚ญใƒณใƒ›ใƒซใƒ€ใƒผใฎใƒ›ใƒƒใ‚ฏใ‚’ๅค–ใ—ใพใ™ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชไบคๆ›

1. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒดไฝ“ใ‚’้–‹ใใพใ™ใ€‚

2. ใ‚นใ‚ญใƒณใฏ่ƒดไฝ“ใฎๅณๅดใธ็•ณใ‚“ใงใŠใใพใ™ใ€‚

3. ้™ค็ดฐๅ‹•ใ‚ณใƒใ‚ฏใ‚ฟ ใ‚ฑใƒผใƒ–ใƒซใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

4. ้™ค็ดฐๅ‹•ใ‚ณใƒใ‚ฏใ‚ฟ ใ‚ฑใƒผใƒ–ใƒซใฏใ€่ƒธ้ƒจๅž‹ๆž ใฎไธ‹ใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ

ๅณๅดใงๅ–ใ‚Šๅค–ใ•ใชใ‘ใ‚Œใฐใชใ‚Šใพใ›ใ‚“ใ€‚

ๆณจ๏ผš่…น้ƒจใฎใƒ•ใ‚ฉใƒผใƒ ใจใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ้–“ใซๆŽฅ็ถšใ•ใ‚Œใฆใ„ใ‚‹ ใƒใƒฅใƒผใƒ–ใ‚„ใ‚ฑใƒผใƒ–ใƒซใฏๅค–ใ•ใชใ„ใงใใ ใ•ใ„ใ€‚

5. ใ‚นใƒ†ใƒƒใƒ— 1๏ฝž4 ใ‚’้€†ใฎ้ †ๅบใง่กŒใ„ใ€่ƒดไฝ“ใฎใ‚นใ‚ญใƒณใ‚’ไบคๆ›ใ—ใพใ™ใ€‚

2. ใƒใƒƒใƒ†ใƒช ใ‚นใƒˆใƒฉใƒƒใƒ—ใ‹ใ‚‰ใƒใƒƒใƒ†ใƒชใ‚’ใ‚นใƒฉใ‚คใƒ‰ใ•ใ›ใฆๅค–ใ—ใพใ™

3. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๅ†…ใฎใƒใƒƒใƒ†ใƒช้›ปๆบๆŽฅ็ถš้ƒจใ‚’ๅผ•ใไธŠใ’ใพใ™ใ€‚ใƒใƒƒใƒ†ใƒช้›ปๆบๆŽฅ็ถš้ƒจใฎใƒ›ใƒƒใ‚ฏใ‚’ๅค–ใ—ใพใ™ใ€‚

4. ใƒใƒƒใƒ†ใƒชใ‚’ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‹ใ‚‰ๅค–ใ—ใพใ™ใ€‚

5. ๅ……้›ปๆธˆใฟใฎใƒใƒƒใƒ†ใƒชใจไบคๆ›ใ™ใ‚‹ใ‹ใ€ๆญฃ่ฆๅ“ใฎๆ–ฐๅ“ SimJunior ใƒใƒƒใƒ†ใƒชใ‚’็”จๆ„ใ—ใพใ™ใ€‚

6. ใƒใƒƒใƒ†ใƒชใ‚’ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใซๆŽฅ็ถšใ—ใพใ™ใ€‚

7. ไธŠๅŠ่บซใฎใ‚นใ‚ญใƒณใ‚’ไบคๆ›ใ—ใพใ™ใ€‚

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

Page 192: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

190

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชๅ……้›ป

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชใฏใ€ๆ“ไฝœไธญใซ่‡ชๅ‹•็š„ใซๅ……้›ปใ•ใ‚Œใพใ™ใ€‚ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใƒใƒƒใƒ†ใƒชใฏใ€ๅฟ…่ฆใซๅฟœใ˜ใฆใ€ใ‚ชใƒ—ใ‚ทใƒงใƒณใฎๅค–้ƒจ้›ปๆบใ‚ขใƒ€ใƒ—ใ‚ฟใ‚’ไฝฟใฃใฆๅ……้›ปใงใใพใ™ใ€‚

1. Link Box ็ตŒ็”ฑใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ้›ปๆบใ‚’ๅˆ‡ใ‚Šใพใ™ใ€‚

2. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‹ใ‚‰ใƒใƒƒใƒ†ใƒชใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

3. ๅค–้ƒจ AC ใ‚ขใƒ€ใƒ—ใ‚ฟใ‚’ใƒใƒƒใƒ†ใƒชใซๆŽฅ็ถšใ—ใพใ™ใ€‚้›ปๆบใ‚ณใƒผใƒ‰ใ‚’ ใ‚ณใƒณใ‚ปใƒณใƒˆใซๆŽฅ็ถšใ—ใพใ™ใ€‚

4. ใƒใƒƒใƒ†ใƒชใฎๅ……้›ปใŒ็ต‚ไบ†ใ—ใŸใ‚‰ใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๅ†…ใฎใƒใƒƒใƒ†ใƒชใ‚’ ไบคๆ›ใ—ใพใ™ใ€‚

ๅ‘ผๅธใƒใƒซใƒผใƒณใฎไบคๆ› ๅ‘ผๅธใƒใƒซใƒผใƒณใฏใ€่‚บใฎไธ‹ใฎไธญๅฟƒใซใ‚ใ‚‹่ƒธ้ƒจใƒ—ใƒฌใƒผใƒˆใฎไธ‹็ซฏ้ƒจใซใ‚ใ‚Šใพใ™ใ€‚

1. ไธŠๅŠ่บซใ‚นใ‚ญใƒณใ‚’้–‹ใใ€่ƒธ้ƒจใƒ—ใƒฌใƒผใƒˆใ‚’้œฒๅ‡บใ•ใ›ใพใ™ใ€‚ใ€ŒไธŠๅŠ่บซใ‚’้–‹ใใ€ใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

2. ่‚บใซๆŽฅ็ถšใ•ใ‚Œใฆใ„ใ‚‹้€ๆ˜Žใชใƒใƒฅใƒผใƒ–ใ‚’ๅค–ใ—ใ€่‚บใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚่ฉณ็ดฐใฏใ€ใ€Œ่‚บใฎไบคๆ›ใ€ใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

3. ๅ‘ผๅธใƒใƒซใƒผใƒณใซๆŽฅ็ถšใ•ใ‚Œใฆใ„ใ‚‹้€ๆ˜Žใชใƒใƒฅใƒผใƒ–ใ‚’ๅค–ใ—ใพใ™ใ€‚

4. ๅคใ„ใƒใƒซใƒผใƒณใ‚’ๆจใฆใพใ™ใ€‚

5. ๆ–ฐใ—ใ„ใƒใƒซใƒผใƒณใ‚’ๅ–ใ‚Šไป˜ใ‘ใพใ™ใ€‚

6. ใƒใƒฅใƒผใƒ–ใ‚’ๆ–ฐใ—ใ„ใƒใƒซใƒผใƒณใซๅ†ๆŽฅ็ถšใ—ใพใ™ใ€‚

7. ่ƒดไฝ“ใ‚’้–‰ใ˜ใฆใ€่ƒดไฝ“ใฎใ‚นใ‚ญใƒณใ‚’ๅ…ƒใฎไฝ็ฝฎใซๆˆปใ—ใพใ™ใ€‚

่‚บใฎไบคๆ› ๆผใ‚ŒใŒใ‚ใ‚‹ๅ ดๅˆใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒธ่…”ๅ†…ใซใ‚ใ‚‹่‚บใ‚’ไบคๆ›ใ™ใ‚‹ๅฟ…่ฆ ใŒใ‚ใ‚Šใพใ™ใ€‚

1. ่ƒดไฝ“ใ‚’้–‹ใใพใ™ใ€‚

2. ไธก่‚บใฎไธ‹ใซ็น‹ใŒใฃใฆใ„ใ‚‹้€ๆ˜Žใชใƒใƒฅใƒผใƒ–ใ‚’ๅค–ใ—ใพใ™ใ€‚ใ€Œๅ‘ผๅธ ใƒใƒซใƒผใƒณใฎไบคๆ›ใ€ใฎใ‚นใƒ†ใƒƒใƒ— 2 ใฎ่ชฌๆ˜Žใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

3. ่‚บใฎไธŠ้ƒจไธญๅคฎใ‹ใ‚‰่‚บใƒใƒซใƒผใƒณ ใ‚ฏใƒชใƒƒใƒ—ใ‚’ๅค–ใ—ใพใ™ใ€‚

4. ่‚บใฎไธŠ้ƒจไธญๅคฎ้ƒจใ‚’ใ‚ฝใ‚ฑใƒƒใƒˆใ‹ใ‚‰้™ใ‹ใซๅผ•ใฃๅผตใ‚Šใพใ™ใ€‚

5. ้€†ใฎๆ‰‹้ †ใงใ€ๆ–ฐใ—ใ„่‚บใ‚’ๅ–ใ‚Šไป˜ใ‘ใพใ™ใ€‚

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

Page 193: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

191

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‚นใ‚ญใƒณใฎไบคๆ› ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚นใ‚ญใƒณใฏใ€่ฃ‚ใ‘ใŸใ‚Šใ€็ฉดใŒใ‚ใ„ใŸใ‚Šใ€ๆฑšใ‚ŒใŸใ‚Šใ—ใŸ้š›ใซใฏไบคๆ›ใŒๅฟ…่ฆใงใ™ใ€‚

ไธŠๅŠ่บซใ‚นใ‚ญใƒณ๏ผš ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒดไฝ“ใ‚นใ‚ญใƒณใ‚’ไบคๆ›ใ™ใ‚‹ใซใฏใ€ใ€Œ่ƒดไฝ“ใ‚’้–‹ใ‘ใ‚‹ใ€ใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

ใ‚ขใƒผใƒ ใฎใ‚นใ‚ญใƒณ๏ผšไปฅไธ‹ใฎๆ‰‹้ †ใงใ‚ขใƒผใƒ ใฎใ‚นใ‚ญใƒณใ‚’ไบคๆ›ใ—ใพใ™ใ€‚

1. ๅคใ„ใ‚ขใƒผใƒ ใ‚นใ‚ญใƒณใ‚’ๅผ•ใฃๅผตใฃใฆๅค–ใ™ใ€ๆˆ–ใ„ใฏใ‚นใ‚ญใƒณใ‚’ๅˆ‡ใ‚Šใพใ™*ใ€‚

่ญฆๅ‘Š๏ผš*ไธญใฎใ‚ขใƒผใƒ ใซ็ฉดใ‚’ใ‚ใ‘ใŸใ‚Šใ€ๅˆ‡ใฃใŸใ‚Šใ—ใชใ„ใ‚ˆใ†ใ” ๆณจๆ„ใใ ใ•ใ„ใ€‚

2. ๅคใ„ใ‚นใ‚ญใƒณใ‚’ๅปƒๆฃ„ใ—ใพใ™ใ€‚

3. ๆป‘ใ‚Šใ‚’่‰ฏใใ™ใ‚‹็‚บใ€ไฝŽๅˆบๆฟ€ๆ€งใฎๆถฒไฝ“ๆด—ๅ‰คๆฐดๆบถๆถฒใ‚’ๆ–ฐใ—ใ„ใ‚ขใƒผใƒ ใ‚นใ‚ญใƒณใฎๅ†…ๅดใซๅก—ๅธƒใ—ใพใ™ใ€‚

4. ๆป‘ใ‚Šใ‚’่‰ฏใใ™ใ‚‹็‚บใ€ไฝŽๅˆบๆฟ€ๆ€งใฎ็Ÿณ้นธๆฐดใ‚’ใ‚ขใƒผใƒ ใซๅก—ๅธƒใ—ใพใ™ใ€‚

5. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆ‰‹ใ‚’ใ‚นใ‚ญใƒณใฎไธญใซๅทฎใ—่พผใฟใพใ™ใ€‚

6. ๆ‰‹่ข‹ใ‚’ใฏใ‚ใ‚‹ใ‚ˆใ†ใซใ€ๆŒ‡ใฎ้ƒจๅˆ†ใฎ็šฎ่†šใ‚’ๆญฃใ—ใใƒ•ใ‚ฃใƒƒใƒˆใ•ใ›ใพใ™ใ€‚

7. ใ‚ขใƒผใƒ ใซๆฒฟใฃใฆใ‚นใ‚ญใƒณใ‚’ๅพใ€…ใซๅผ•ใไธŠใ’ใพใ™ใ€‚

ๆ–ฐใ—ใ„ใ‚ขใƒผใƒ ใ‚’ๅ–ใ‚Šไป˜ใ‘ใ‚‹ใซใฏใ€ไปฅไธ‹ใฎๆ‰‹้ †ใ‚’ๅฎŸ่กŒใ—ใพใ™ใ€‚

ๅณ IV ใ‚ขใƒผใƒ ใฎไบคๆ›

1. ใ€Œ่ƒดไฝ“ใ‚’้–‹ใใ€ใ‚’ๅ‚็…งใ—ใฆใ€่ƒดไฝ“ใ‚’้–‹ใใพใ™ใ€‚

2. ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่‚ฉใซใ‚ขใƒผใƒ ใ‚’ๅ›บๅฎšใ—ใฆใ„ใ‚‹ใƒœใƒซใƒˆใ‚’็ทฉใ‚ใ€ๅคใ„ ใ‚ขใƒผใƒ ใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

3. ่‚ฉใฎใƒใ‚ธใŒๅๅˆ†็ทฉใฟใ€ใ‚ขใƒผใƒ ใฎ่ปธใŒใ‚นใƒฉใ‚คใƒ‰ใ—ใฆๅค–ใ‚Œใ‚‹ใ“ใจใ‚’็ขบ่ชใ—ใพใ™ใ€‚

4. ๅคใ„ใ‚ขใƒผใƒ ใ‚’ๅปƒๆฃ„ใ—ใพใ™ใ€‚

1. ่…•ใฎ่ปธใŒใ‚นใƒ ใƒผใ‚บใซๅ…ฅใ‚‹ใ‚ˆใ†ใซใ€่‚ฉใฎใญใ˜ใ‚’ๅๅˆ†ใซ็ทฉใ‚ใฆใŠใใพใ™ใ€‚

2. ่ƒดไฝ“ใซใ‚ขใƒผใƒ ใ‚’ๆŽฅ็ถšใ—ใพใ™ใ€‚

3. ่ปธใŒๅ–ใ‚Šไป˜ใ‘้‡‘ๅ…ทใฎๅ†…้ƒจใซใดใฃใŸใ‚Š้‡ใญใ€่‚ฉใฎๅ–ใ‚Šไป˜ใ‘้‡‘ๅ…ทใซ ่…•ใฎ่ปธใ‚’ๆ…Ž้‡ใซๆŠผใ—่พผใฟใพใ™ใ€‚

4. ่‚ฉใฎใƒใ‚ธใ‚’ๅ…ญ่ง’ใƒฌใƒณใƒใง็ท ใ‚ใพใ™ใ€‚

ๅณ IO ใƒฌใƒƒใ‚ฐใฎไบคๆ› ไปฅไธ‹ใฎๆ‰‹้ †ใงๅณ IO ใƒฌใƒƒใ‚ฐใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

1. ใƒฌใƒƒใ‚ฐใฎไธญใฎๆถฒไฝ“ใŒ็ฉบใซใชใฃใฆใ„ใ‚‹ใ“ใจใ‚’็ขบ่ชใ—ใพใ™ใ€‚

2. ใƒฌใƒƒใ‚ฐใ‚’ๅ›บๅฎšใ—ใฆใ„ใ‚‹ใƒœใƒซใƒˆใ‚’็ทฉใ‚ใ€ๅคใ„ IO ใƒฌใƒƒใ‚ฐใ‚’ๅ–ใ‚Šๅค–ใ—ใพใ™ใ€‚

3. IO ใƒฌใƒƒใ‚ฐใ‚’ๅค–ใ—ใพใ™ใ€‚

4. ๅคใ„ IO ใƒฌใƒƒใ‚ฐใ‚’ๅปƒๆฃ„ใ—ใพใ™ใ€‚

ไธŠ่จ˜ใฎๆ‰‹้ †ใ‚’้€†ใซใ—ใฆๆ–ฐใ—ใ„ IO ใƒฌใƒƒใ‚ฐใ‚’ๅ–ใ‚Šไป˜ใ‘ใพใ™ใ€‚

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

Page 194: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

192

ใ‚ทใ‚นใƒ†ใƒ ่จญๅฎš

ๅ•้กŒ

โ€ข ใƒ‡ใƒผใ‚ฟๆๅคฑใ‚„ใ‚ทใ‚นใƒ†ใƒ ้šœๅฎณ (ไธ€่ˆฌใ‚ทใ‚นใƒ†ใƒ ้šœๅฎณ)ใ€‚

่งฃๆฑบๆณ•

โ€ข ใ‚ทใ‚นใƒ†ใƒ ใŒใ‚ทใƒฃใƒƒใƒˆใƒ€ใ‚ฆใƒณใ—ใŸใ‚Šใ€ใ™ในใฆใฎใƒ‡ใƒผใ‚ฟใŒๆๅคฑใ‚ใ‚‹ใ„ใฏ็ ดๆใ—ใŸๅ ดๅˆใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผใพใงใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

LLEAP

โ€ข ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซ > LLEAP > ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ ใ‚ฌใ‚คใƒ‰ใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ (Laerdal Simulation Home ใ‹ใ‚‰ใƒ˜ใƒซใƒ—ใซใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝใงใ™)ใ€‚

ใƒฌใƒผใƒซใƒ€ใƒซ Patient Monitor

โ€ข ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขใƒ˜ใƒซใƒ—ใƒ•ใ‚กใ‚คใƒซ > ใƒฌใƒผใƒซใƒ€ใƒซ Patient Monitor > ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ ใ‚ฌใ‚คใƒ‰ใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ (Laerdal Simulation Home ใ‹ใ‚‰ใƒ˜ใƒซใƒ—ใซใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝใงใ™)ใ€‚

ใƒ‡ใ‚ฃใƒ–ใƒชใƒผใƒ•ใ‚ฃใƒณใ‚ฐใŠใ‚ˆใณใƒ“ใƒ‡ใ‚ชใƒฌใ‚ณใƒผใƒ‡ใ‚ฃใƒณใ‚ฐโ€ข SimView ใƒ˜ใƒซใƒ—ใฎใƒˆใƒฉใƒ–ใƒซใƒผใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ (SimView ็”ป้ขไธ‹้ƒจใฎ

ใƒชใƒณใ‚ฏใ‹ใ‚‰ใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝ) ใพใŸใฏ Session Viewer ใƒ˜ใƒซใƒ—ใฎใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ ใ‚ฌใ‚คใƒ‰ (Laerdal Simulation Home ใ‹ใ‚‰ใ‚ขใ‚ฏใ‚ปใ‚นๅฏ่ƒฝ) ใฎใ‚ปใ‚ฏใ‚ทใƒงใƒณใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟ

ๅ•้กŒ

โ€ข ไบˆๆƒณๅค–ใฎๅ‹•ไฝœใ‚’ใ™ใ‚‹ใ€‚

่งฃๆฑบๆณ•

โ€ข ใ‚ฑใƒผใƒ–ใƒซใ€ใƒใƒฅใƒผใƒ–ใ‚ใ‚‹ใ„ใฏใ‚ณใƒใ‚ฏใ‚ฟใฎๆŽฅ็ถšใŒ็ทฉใใชใฃใฆใ„ใ‚‹ใจใ€ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ชคไฝœๅ‹•ใŒ็”Ÿใ˜ใ‚‹ๅ ดๅˆใŒใ‚ใ‚Šใพใ™ใ€‚่ƒดไฝ“ใ‚’้–‹ใใ€ๆŽฅ็ถš ใฎๅค–ใ‚Œใฆใ„ใ‚‹้ƒจๅ“ใŒใชใ„ใ‹็ขบ่ชใ—ใฆใใ ใ•ใ„ใ€‚ใ€Œใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ ใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ— - ไธŠๅŠ่บซใ‚’้–‹ใใ€ใฎใ‚ปใ‚ฏใ‚ทใƒงใƒณใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

โ€ข ๆถฒไฝ“ใŒๆผใ‚Œใฆใ„ใ‚‹ๅ ดๅˆใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ้›ปๆบใ‚’ๅˆ‡ใ‚Šใ€ใƒฌใƒผใƒซใƒ€ใƒซ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผใซใ”้€ฃ็ตกใใ ใ•ใ„ใ€‚

ๆฐ—้“ใฎๆฑšใ‚Œ

ๅ•้กŒ

โ€ข ๅฃๅฏพๅฃไบบๅทฅๅ‘ผๅธใงใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆฐ—้“ใŒๆฑšๆŸ“ใ•ใ‚ŒใŸใ€‚

่งฃๆฑบๆณ•

โ€ข ใƒžใƒใ‚ญใƒณใƒฏใ‚คใƒ—ใงใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅค–ๅดใ‚’ๆ‹ญใใพใ™ใ€‚ใƒžใƒใ‚ญ ใƒณใƒฏใ‚คใƒ—ใงๅฃ่…”ๅ†…ใ‚’ๆ‹ญใใพใ™ใ€‚่‚บใƒใƒซใƒผใƒณใ‚’ไบคๆ›ใ—ใพใ™ใ€‚ ใ€Œใƒกใƒณใƒ†ใƒŠใƒณใ‚น - ่‚บใƒใƒซใƒผใƒณใฎไบคๆ›ใ€ใฎ็ซ ใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

่ƒธ้ƒจใฎๅ‹•ใ

ๅ•้กŒ

โ€ข ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ่ƒธ้ƒจใŒๆŒ™ไธŠใ—ใชใ„ใ€‚

่งฃๆฑบๆณ•

โ€ข ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎ้›ปๆบใŒใ‚ชใƒณใซใชใฃใฆใ„ใ‚‹ใ“ใจใ‚’็ขบ่ชใ—ใพใ™ใ€‚

โ€ข SimPad ใพใŸใฏ LLEAP ใงไปฅไธ‹ใ‚’็ขบ่ชใ—ใพใ™ใ€‚

โ€“ ๅ‘ผๅธๆ•ฐ (awRR) ใŒใ‚ผใƒญใซ่จญๅฎšใ•ใ‚Œใฆใ„ใชใ„ใ€‚

โ€“ ่ƒธ้ƒญๆŒ™ไธŠใŒใ‚ชใƒ•ใซ่จญๅฎšใ•ใ‚Œใฆใ„ใชใ„ใ€‚

โ€“ ๅฟƒ้›ปๅ›ณใŒ่ก€ๆตใ‚’ไผดใ†่จญๅฎšใซใชใฃใฆใ„ใ‚‹ใ€‚

โ€“ ๆฐ—้“ๆŠตๆŠ—ใ‚„ๅ’ฝ้ ญ็—™ๆ”ฃใชใฉใฎๆฐ—้“ๅˆไฝต็—‡ใŒ่จญๅฎšใ•ใ‚Œใฆใ„ใชใ„ใ€‚

โ€“ ๅ†…่”ตใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŒ LLEAP ใงไฝฟ็”จๅฏ่ƒฝใจใชใฃใฆใ„ใ‚‹ใ€‚ ใ€Œๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใ‚’ใ‚ชใƒ•ใซใ™ใ‚‹ใ€ใฎใ‚ปใ‚ฏใ‚ทใƒงใƒณใ‚’ใ”ๅ‚็…งใใ ใ•ใ„ใ€‚

โ€ข ๅค–้ƒจๅœง็ธฎ็ฉบๆฐ—ๆบ(ใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใชใฉ)ใฎ้›ปๆบใŒใ‚ชใƒ•ใซใชใฃใฆ ใŠใ‚Šใ€ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใ‹ใ‚‰ๅ–ใ‚Šๅค–ใ•ใ‚Œใฆใ„ใ‚‹ใ‹็ขบ่ชใ—ใฆใใ ใ•ใ„ใ€‚

โ€ข ๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŒใ‚ชใƒผใƒใƒผใƒ’ใƒผใƒˆใ—ใฆใ„ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Š ใพใ™ใ€‚ใ‚ฏใƒผใƒซใƒ€ใ‚ฆใƒณใ™ใ‚‹ใพใง็ด„ 20 ๅˆ†ๅพ…ใกใพใ™ใ€‚

โ€ข ็‰‡ๅดใฎ่ƒธใ—ใ‹ๆŒ™ไธŠใ—ใชใ„็Šถๆ…‹ (ไพ‹ใˆใฐๆฐ—็ฎกใƒใƒฅใƒผใƒ–ใŒ็‰‡่‚บ ๆŒฟ็ฎกใซใชใฃใฆใ„ใ‚‹ใชใฉ) ใซใชใฃใฆใ„ใ‚‹ใ€‚

โ€ข ๅ‘ผๅธใƒใƒซใƒผใƒณใ‹ใ‚‰็ฉบๆฐ—ใŒๆผใ‚Œใฆใ„ใ‚‹ใ‹ใ€ๅ‘ผๅธใƒใƒซใƒผใƒณใธใฎ ใƒใƒฅใƒผใƒ–ใŒใญใ˜ใ‚ŒใฆๅฑˆๆŠ˜ใ—ใฆใ„ใ‚‹ใ‹ใ€ใพใŸใฏๅค–ใ‚Œใฆใ„ใ‚‹ใ€‚ ๆผใ‚Œใฆใ„ใ‚‹ๅ ดๅˆใฏๅ‘ผๅธใƒใƒซใƒผใƒณใ‚’ไบคๆ›ใ—ใฆใใ ใ•ใ„ใ€‚ ใ€Œใƒกใƒณใƒ†ใƒŠใƒณใ‚น - ๅ‘ผๅธใƒใƒซใƒผใƒณใฎไบคๆ›ใ€ใฎใ‚ปใ‚ฏใ‚ทใƒงใƒณใ‚’ๅ‚็…งใ—ใฆใใ ใ•ใ„ใ€‚

โ€ข ๆฐ—้“ใชใฉใฎๆŽฅ็ถšใซๆผใ‚ŒใŒใชใ„ใ‹็ขบ่ชใ—ใพใ™ใ€‚ใ™ในใฆใฎๆŽฅ็ถšใŒ ๅฎŒๅ…จใช็Šถๆ…‹ใ‹ใฉใ†ใ‹็ขบ่ชใ—ใพใ™ใ€‚ๆผใ‚ŒใŒใ‚ใ‚‹ๅ ดๅˆใ€่ฉฒๅฝ“ใƒ‘ใƒผใƒ„ ใ‚’ไบคๆ›ใ—ใพใ™ใ€‚

โ€ข ่ƒธ้ƒจใฎๅ‹•ใใŒๆต…ใใ€ๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŒๅธธใซๅ‹•ไฝœใ—ใฆใ„ใ‚‹ใ€‚ๅ†…้ƒจใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŒๆ‘ฉ่€—ใ—ใฆใ„ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Šใพใ™ใ€‚ใƒฌใƒผใƒซใƒ€ใƒซ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ตใƒผใƒ“ใ‚นใพใงใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

Page 195: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

193

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

่‚บ

ๅ•้กŒ

โ€ข ่‚บใŒๆญฃใ—ใๆฉŸ่ƒฝใ—ใชใ„

่งฃๆฑบๆณ•

โ€ข ไธŠๅŠ่บซใจ่ƒธ้ƒจใƒ—ใƒฌใƒผใƒˆใ‚’้–‹ใใพใ™ใ€‚่‚บใŒ่‡ช็”ฑใซ่†จใ‚‰ใฟใ€ใ‚ฑใƒผใƒ–ใƒซใŒ้‚ช้ญ”ใซใชใฃใฆใ„ใชใ„ใ‹็ขบ่ชใ—ใพใ™ใ€‚

โ€ข ่‚บใŒ้ฉๅˆ‡ใซๆŽฅ็ถšใ•ใ‚ŒใฆใŠใ‚Šใ€ใƒใƒฅใƒผใƒ–ใŒใญใ˜ใ‚Œใฆใ„ใชใ„ใ“ใจใ‚’็ขบ่ชใ—ใพใ™ใ€‚

โ€ข ่‚บใŒๆฐดๅนณใซใ€ไธ”ใค้ฉๅˆ‡ใชไฝ็ฝฎใง่ฃ…็€ใ•ใ‚Œใฆใ„ใ‚‹ใ“ใจใ‚’็ขบ่ชใ—ใพใ™ใ€‚

โ€ข ่‚บใซๅ‰ฒใ‚Œ็›ฎใ‚„่ฃ‚ใ‘็›ฎใŒใ‚ใ‚‹ใ‹ใฉใ†ใ‹ใ‚’็ขบ่ชใ—ใพใ™ใ€‚

โ€ข ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆฐ—้“ๅ†…้ƒจใง็ฉบๆฐ—ใฎๆตใ‚Œใ‚’้ฎใ‚‹ๅŽŸๅ› ใŒ็„กใ„ใ‹็ขบ่ช ใ—ใพใ™ใ€‚

โ€ข ่‚บใ‚ณใƒณใƒ—ใƒฉใ‚คใ‚ขใƒณใ‚นใ‚’่ชฟๆ•ดใ—ใฆใ‚‚ๅค‰ๅŒ–ใŒใชใ„ๅ ดๅˆใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผใพใงใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

โ€ข ่‚บๆŠตๆŠ—ใซๅค‰ๅŒ–ใŒใชใ„ๅ ดๅˆใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซ ใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผ ใพใงใŠๅ•ใ„ๅˆใ‚ใ›ใใ ใ•ใ„ใ€‚

่ด่จบไธญใซๆฉŸๆขฐใฎๅ‹•ไฝœ้ŸณใŒๆฐ—ใซใชใ‚‹LLEAP ใงใ€<่ด่จบใƒŸใƒฅใƒผใƒˆ> ใ‚’ใ‚ฏใƒชใƒƒใ‚ฏใ—ใพใ™ใ€‚

่„ˆๆ‹ (ๆฉˆ้ชจๅ‹•่„ˆใŠใ‚ˆใณไธŠ่…•)

ๅ•้กŒ

โ€ข ่„ˆๆ‹ใ‚’ๆ„Ÿ็Ÿฅใงใใชใ„

่งฃๆฑบๆณ•

โ€ข ่„ˆๆ‹ใƒฆใƒ‹ใƒƒใƒˆใŒใ‚นใ‚ญใƒณใงใใคใ่ฆ†ใ‚ใ‚Œใ™ใŽใฆใ„ใ‚‹ๅฏ่ƒฝๆ€งใŒใ‚ใ‚Š ใพใ™ใ€‚ใ‚นใ‚ญใƒณใ‚’่ชฟ็ฏ€ใ—็›ดใ—ใฆใใ ใ•ใ„ใ€‚

โ€ข ่ก€ๅœงใ‚’ 60 mmHg ไปฅไธŠใซ่จญๅฎšใ—ใฆใใ ใ•ใ„ใ€‚

โ€ข ใ‚ณใƒณใƒ—ใƒฌใƒƒใ‚ตใŒใ‚ชใƒณใซใชใฃใฆใ„ใ‚‹ใ“ใจใ‚’็ขบ่ชใ—ใฆใใ ใ•ใ„ใ€‚

ๆณจ๏ผš่ก€ๅœงใ‚’ 60 ไปฅไธ‹ใซ่จญๅฎšใ™ใ‚‹ใจๆœซๆขขๅ‹•่„ˆใฎๆ‹ๅ‹•ใŒใชใใชใ‚Šใพใ™ใ€‚

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ทใƒฃใƒƒใƒˆใƒ€ใ‚ฆใƒณ

ๅ•้กŒ

โ€ข ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅๅฟœใŒใชใ„ใ€‚

่งฃๆฑบๆณ•

1. Link Box ใฎ้›ปๆบใ‚’ใ‚ชใƒ•ใซใ—ใพใ™ใ€‚

2. SimPad ใฎ้›ปๆบใ‚’ไธ€ๆ—ฆใ‚ชใƒ•ใซใ™ใ‚‹ใ€ใพใŸ LLEAP ใ‚’ไฝฟ็”จใ—ใฆใ„ใ‚‹ ๅ ดๅˆใฏใ€ใ‚คใƒณใ‚นใƒˆใƒฉใ‚ฏใ‚ฟใƒผ PC ใ‚’ไธ€ๆ—ฆ็ต‚ไบ†ใ—ใพใ™ใ€‚

3. ใ™ในใฆใ‚’ๅ†่ตทๅ‹•ใ—ใพใ™ใ€‚

ใ“ใ‚Œใงใ‚‚็ŠถๆณใŒๆ”นๅ–„ใ—ใชใ„ๅ ดๅˆใฏใ€ใƒฌใƒผใƒซใƒ€ใƒซใƒ†ใ‚ฏใƒ‹ใ‚ซใƒซใ‚ปใƒณใ‚ฟใƒผใพใงใ”้€ฃ็ตกใใ ใ•ใ„ใ€‚

Page 196: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

194

ๆณจ

Page 197: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

195

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ใƒžใƒใ‚ญใƒณๅฏธๆณ• ้•ทใ•๏ผๅน… (ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆœฌไฝ“)๏ผš120 cm x 42.5 cm ้‡้‡ (ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆœฌไฝ“)๏ผš11.36 kg

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟ้›ปๆบ ๅค–้ƒจ้›ปๆบ๏ผš ๅ…ฅๅŠ›้›ปๅœง 9 VDCใ€1.5 A ๅ†…้ƒจใƒใƒƒใƒ†ใƒช๏ผš 7.4 Vใ€4.4 Ahใ€ใƒชใƒใ‚ฆใƒ ใ‚คใ‚ชใƒณ

ๅฐ‚็”จใฎ SimJunior ๅค–้ƒจ้›ปๆบใŠใ‚ˆใณใƒใƒƒใƒ†ใƒชใฎใฟใ‚’ไฝฟ็”จใ—ใฆใใ ใ•ใ„ใ€‚

็ฉบๆฐ—ๅœง ๅ†…้ƒจ็ฉบๆฐ—ใ‚ฟใƒณใ‚ฏ๏ผš ๆœ€ๅคง 6 psi ๅค–้ƒจ็ฉบๆฐ—ๆŽฅ็ถš๏ผš ๆœ€ๅคง 16 psi

ๆธฉๅบฆๅˆถ้™ ไฝฟ็”จๆธฉๅบฆ๏ผš +4ยบC ใ‹ใ‚‰ 40ยบC ไฟ็ฎกๆธฉๅบฆ๏ผš -15ยบC ใ‹ใ‚‰ 50ยบC

็’ฐๅขƒ - ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟๆœฌไฝ“ ็›ธๅฏพๆนฟๅบฆ๏ผš 20%๏ฝž90% (็ต้œฒใชใ—) ๆนฟใฃใŸๅฑ‹ๅค–็’ฐๅขƒใงใฎไฝฟ็”จใฏใŠใ‚„ใ‚ใใ ใ•ใ„ใ€‚ ๅกฉ้ขจ่ฉฆ้จ“ใฏ่กŒใฃใฆใ„ใพใ›ใ‚“ใ€‚

็„ก็ทš้€šไฟก ไฝœๅ‹•็ฏ„ๅ›ฒ๏ผš ๆœ€ๅคง 10 m

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๅŽŸๆๆ–™ไธ€่ฆง ่กฃๆœ๏ผš ็ถฟใ€ใƒŠใ‚คใƒญใƒณ ใ‚นใ‚ญใƒณใจๆฐ—้“๏ผš PVC ๅค–้ƒจ็กฌ่ณชใƒ—ใƒฉใ‚นใƒใƒƒใ‚ฏ๏ผš PVCใ€ABS ๅ†…้ƒจใƒ—ใƒฉใ‚นใƒใƒƒใ‚ฏ๏ผš ใ‚ทใƒชใ‚ณใƒณใ€TPUใ€PVCใ€ใƒ‹ใƒˆใƒชใƒซ ABSใ€POMใ€ใƒŠใ‚คใƒญใƒณ + GF ใ‚จใƒใ‚ญใ‚ทใƒใƒชใ‚ฆใƒฌใ‚ฟใƒณ ้‡‘ๅฑž้ƒจๅ“๏ผš ใ‚ขใƒซใƒŸใƒ‹ใ‚ฆใƒ ใ€็œŸใกใ‚…ใ†ใ€้‰„

ใ‚ณใƒณใƒ”ใƒฅใƒผใ‚ฟๆœ€ไฝŽ่ฆไปถ

โ€ข Intel i-core ็ฌฌ 3 ไธ–ไปฃไปฅ้™

โ€ข PassMark ใƒ™ใƒณใƒโ€•ใƒžใƒผใ‚ฏใ‚นใ‚ณใ‚ข 3,000 ไปฅไธŠ

โ€ข 4 GB RAM

โ€ข ใƒใƒผใƒ‰ใƒ‡ใ‚ฃใ‚นใ‚ฏ็ฉบใๅฎน้‡ 120 GB

โ€ข 1,366 x 768 ไปฅไธŠ

โ€ข ใƒžใ‚คใ‚ฏไป˜ใใƒ˜ใƒƒใƒ‰ใ‚ปใƒƒใƒˆ

โ€ข USB ใƒใƒผใƒˆ x 2

ใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ขๆœ€ไฝŽๅ‹•ไฝœ่ฆไปถ โ€ข Windows 7 ใพใŸใฏ Windows 8

โ€ข 100% DPI

ๆด—ๆต„ๆถฒ ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎๆด—ๆต„ใซใฏใ€ไปฅไธ‹ใฎใ„ใšใ‚Œใ‹ใ‚’ใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

โ€“ 60% ใ‚คใ‚ฝใƒ—ใƒญใƒ‘ใƒŽใƒผใƒซใ‚ขใƒซใ‚ณใƒผใƒซ

โ€“ 70% ใ‚จใ‚ฟใƒŽใƒผใƒซ

โ€“ ไฝŽๅˆบๆฟ€ๆ€งใฎๆถฒไฝ“็Ÿณ้นธใŠใ‚ˆใณๆฐด

IV ็”จใฎๆถฒไฝ“ IV ใŠใ‚ˆใณ IO ใฎใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใซใฏใ€่’ธ็•™ๆฐดใพใŸใฏ่„ฑใ‚คใ‚ชใƒณๆฐดใฎใฟใ”ไฝฟ็”จใใ ใ•ใ„ใ€‚

ไป•ๆง˜

Page 198: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

196

ๆณจ

Page 199: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

197

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ทใƒงใƒณใ‚ฝใƒ•ใƒˆใ‚ฆใ‚งใ‚ข

ใ‚ทใƒŸใƒฅใƒฌใƒผใ‚ฟใฎใ‚ปใƒƒใƒˆใ‚ขใƒƒใƒ—

ใƒกใƒณใƒ†ใƒŠใƒณใ‚น

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ไป•ๆง˜

ใฏใ˜ใ‚ใซ

ใƒˆใƒฉใƒ–ใƒซใ‚ทใƒฅใƒผใƒ†ใ‚ฃใƒณใ‚ฐ

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

ๆœ€ๆ–ฐ็‰ˆใฎๆถˆ่€—ๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒชใซใคใ„ใฆใฏใ€www.laerdal.com/jp/ ใ‚’ใ”่ฆงใใ ใ•ใ„

ไบˆๅ‚™้ƒจๅ“ใจใ‚ขใ‚ฏใ‚ปใ‚ตใƒช

Page 200: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

198

ๆณจ

Page 201: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

199

็ปดๆŠค 210

โ€“ ๆฏๆฌกๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ไน‹ๅŽ็š„็ปดๆŠค 210 โ€“ ๆ‰“ๅผ€่บฏๅนฒ 211โ€“ ๆ›ดๆขๆจกๆ‹Ÿไบบ็”ตๆฑ  211 โ€“ ๆจกๆ‹Ÿไบบ็”ตๆฑ ๅ……็”ต 212 โ€“ ๆ›ดๆข้ผ“่ƒธๆฐ”ๅ›Š 212 โ€“ ๆ›ดๆข่‚บ้ƒจๆฐ”ๅ›Š 212โ€“ ๆ›ดๆขๆจกๆ‹Ÿไบบ็šฎ่‚ค 213 โ€“ ๆ›ดๆขๅณ้™่„‰ๆณจๅฐ„่‡‚ 213 โ€“ ๆ›ดๆข้ชจๅ†…ๆณจๅฐ„ๅณ่…ฟ 213

ๆ•…้šœๆŽ’้™ค 214

ไป‹็ป 200

โ€“ ็›‘็ฎกไฟกๆฏ 200 โ€“ ๆจกๆ‹Ÿไบบๅธธ่ง„ไฟๅ…ป 201โ€“ SimJunior ๆฆ‚่งˆๅ›พ 203 โ€“ SimJunior ๅŠŸ่ƒฝ 204

ๆจกๆ‹Ÿไบบ่ฎพๅฎš 207

โ€“ ๆจกๆ‹Ÿๅ‡†ๅค‡ๅทฅไฝœ 207 โ€“ ๅ‡†ๅค‡้ชจๅ†…ๆณจๅฐ„่…ฟ 207 โ€“ ๆณจๅฐ„้™ๆณจๆถฒไฝ“ 207โ€“ ๆŽ’ๅนฒๅคšไฝ™็š„้™ๆณจๆถฒไฝ“ 208โ€“ ๆธ…ๆด—้™่„‰ๆณจๅฐ„่‡‚ 208 โ€“ ๅฎ‰่ฃ…้™ค้ขค้€‚้…ๅ™จๆฟ 208โ€“ ่ฟžๆŽฅ่ก€ๅŽ‹่ข–ๅธฆ 208 โ€“ ๆ กๅ‡† LLEAP ไธญ็š„่ก€ๅŽ‹่ข–ๅธฆ 208 โ€“ ๆ กๅ‡† SimPad ไธญ็š„่ก€ๅŽ‹่ข–ๅธฆ 208โ€“ ๆ›ดๆข็žณๅญ” 209โ€“ ไฝฟ็”จๅค–้ƒจๅŽ‹็ผฉๆœบ 209

่ง„ๆ ผ 217

ๆจกๆ‹Ÿ่ฝฏไปถ 206

โ€“ ๅฏผๅธˆไธชไบบ็”ต่„‘ 206 โ€“ ่ฝฏไปถ่ฎธๅฏ่ฏ 206 โ€“ Laerdal Simulation Home 206โ€“ LLEAP 206โ€“ Voice Conference Application 206โ€“ Patient Monitor 206โ€“ Session Viewer ๅ’Œ SimView Server 206โ€“ ๅ…ถไป–ๅบ”็”จ็จ‹ๅบ 206โ€“ SimDesigner 206โ€“ ๅธฎๅŠฉๆ–‡ๆกฃ 206โ€“ ็ฝ‘้กตไธ‹่ฝฝ 206

ๅค‡ไปถๅ’Œ้…ไปถ 219

็›ฎๅฝ• ZH

Page 202: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

200

ไป‹็ป

ไป‹็ป SimJuniorโ„ข ๆจกๆ‹Ÿ็ณป็ปŸ SimJunior ๆ˜ฏไธ€ไธช้€ผ็œŸ็š„็œŸไบบๅฐบๅฏธๅ„ฟ็ง‘็—…ไบบๆจกๆ‹Ÿไบบ๏ผŒ็”ฑๆŒชๅบฆไธŽ็พŽ

ๅ›ฝๅ„ฟ็ง‘ๅญฆไผšๅ…ฑๅŒ่ฎพ่ฎกใ€‚SimJunior ๅฏ็”จไบŽๅฏนๆฅ่‡ชๅคšไธชๅŒป็–—ๅญฆ็ง‘็š„

ไธ€ๅๆˆ–ๅคšๅๅŒป็–—ๆŠค็†ไธ“ไธšไบบๅ‘˜่ฟ›่กŒ่ฎญ็ปƒใ€‚

SimJunior ๆจกๆ‹Ÿ็ณป็ปŸๅทฒๅฎŒๅ…จ่ฃ…้…ๅฅฝใ€‚ๆ— ้œ€่ฃ…้…ๆจกๆ‹Ÿไบบ้ƒจไปถใ€‚

ๆœ‰ๅ…ณ SimJunior ๆจกๆ‹Ÿๅ‡†ๅค‡ๅทฅไฝœ็š„่ฏฆๆƒ…๏ผŒ่ฏทๅ‚้˜…โ€œๆจกๆ‹Ÿไบบ่ฎพ็ฝฎโ€้ƒจๅˆ†ใ€‚

SimJunior ๅธฎๅŠฉไฟกๆฏ ไฝฟ็”จ่ฏดๆ˜Ž (DFU)

ไฝฟ็”จ SimJunior ๆจกๆ‹Ÿ็ณป็ปŸ็š„ๅˆ†ๆญฅๆŒ‡็คบๅ’Œๅ›พ็คบใ€‚

ๅŽŸๅˆถ้€ ๅ•†็š„็”จๆˆทๆ‰‹ๅ†Œ

ๅบ”้ตๅฎˆๅŽŸๅˆถ้€ ๅ•†ๆไพ›็š„ๆ‰€ๆœ‰ๅ•็‹ฌ็”จๆˆทๆ‰‹ๅ†Œๅ’Œๆ ‡็ญพใ€‚SimJunior ไฝฟ็”จ

่ฏดๆ˜Žๅนถไธๅฏๅ–ไปฃๆˆ–ๆ›ฟไปฃๅŽŸๅง‹ๅˆถ้€ ๅ•†็š„ไฝฟ็”จ่ฏดๆ˜Žใ€‚

SimJunior ๅฟซ้€Ÿ่ฎพ็ฝฎๆŒ‡ๅ—

่ฎพ็ฝฎ SimJunior ๆจกๆ‹Ÿ็ณป็ปŸ็š„ๅˆ†ๆญฅๆŒ‡ๅ—ใ€‚

SimPad ไฝฟ็”จ่ฏดๆ˜Ž (DFU)

SimPad ไฝฟ็”จ่ฏดๆ˜Žๆไพ›ๆœ‰ๅ…ณ SimJunior ไธŽ Link Box ๅŠ SimPad ไฝฟ็”จ

็š„่ฏดๆ˜Žใ€‚

LLEAP ๅธฎๅŠฉๆ–‡ไปถ (Laerdal Learning Application)

ๅฏไปŽ Laerdal Simulation Home ่ฎฟ้—ฎ LLEAP ๅธฎๅŠฉๆ–‡ไปถ๏ผŒ่ฏทๅ‚่ง

Laerdal Simulation Homeใ€‚

ๅธฎๅŠฉไธป้ข˜ๅŒ…ๆ‹ฌ

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

ๆŠ€ๆœฏๆดๅŠฉ

ๅฆ‚้œ€ๆŠ€ๆœฏๆดๅŠฉ๏ผŒ่ฏท่”็ณปๆ‚จๅฝ“ๅœฐ็š„ๆŒชๅบฆๆŠ€ๆœฏๆœๅŠกไธญๅฟƒใ€‚

็ฝ‘้กตไธ‹่ฝฝ

่ฎฟ้—ฎ www.laerdal.com/downloads๏ผŒไธ‹่ฝฝๆœ€ๆ–ฐ็š„ไฝฟ็”จ่ฏดๆ˜Žๅ’Œๆ–ฐ็‰ˆๆจก

ๆ‹Ÿ่ฝฏไปถใ€‚

SimCenter ๅ†…ๅฎน SimCenter ไธบ่Žทๅ–ๆฅ่‡ชๅ…จ็ƒๆจกๆ‹Ÿไธ“ๅฎถ็ป่ฟ‡้ชŒ่ฏ็š„ๅ†…ๅฎนๆไพ›ไพฟๅˆฉ

็š„้€”ๅพ„๏ผŒไปŽ่€Œ่ฎฉๆ‚จๅฏไปฅๅˆฉ็”จไป–ไปฌ็š„็ป้ชŒๅนถไปŽๆฏไธ€ไธชๅญฆไน ๆœบไผšไธญ

่Žท็›Šๆœ€ๅคšใ€‚ๆ‚จๅฐ†ไผšๅ‘็Žฐไธ“ไธบ SimJunior ๅผ€ๅ‘็š„ๅคš็ง็—…ไพ‹ใ€‚่ฎฟ้—ฎ www.mysimcenter.com๏ผŒไบ†่งฃๅฆ‚ไฝ•ๅฏไปฅๅ…จ้ขไผ˜ๅŒ–ๆ‚จ็š„ๅญฆไน ไฝ“้ชŒใ€‚

็›‘็ฎกไฟกๆฏ

Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

ๆณจๆ„ไบ‹้กน ไปปไฝ•ๆœชๅพ—ๅˆฐ็›ธๅ…ณๆ–น๏ผˆ่ดŸ่ดฃๆ ธๆŸฅ่ฏฅ่ฎพๅค‡ๆ˜ฏๅฆๅˆ่ง„๏ผ‰ๆ˜Ž็กฎๆ‰นๅ‡†็š„ๅ˜

ๆ›ดๆˆ–ไฟฎๆ”น้ƒฝๅฏ่ƒฝไฝฟ็”จๆˆทๆ“ไฝœ่ฏฅ่ฎพๅค‡็š„ๆŽˆๆƒๆ— ๆ•ˆใ€‚

่ฏฅไบงๅ“็ฌฆๅˆ็†ไบ‹ไผšๆŒ‡ไปค 2004/108/EC ๅฏนไบŽ็”ต็ฃๅ…ผๅฎนๆ€ง (EMC) ็š„ๅŸบๆœฌ่ฆๆฑ‚ใ€‚

่ฏฅไบงๅ“็ฌฆๅˆ็†ไบ‹ไผšๆŒ‡ไปค 2011/65/EU ๅฏนไบŽไฝฟ็”จๆŸไบ›ๆœ‰ๅฎณ็‰ฉ

่ดจ็š„้™ๅˆถ (RoHS)ใ€‚

Li-ion

้”‚็ฆปๅญ็”ตๆฑ ๅบ”ๅฝ“่ฟ›่กŒๅ›žๆ”ถๅˆฉ็”จใ€‚

ๅค„็†ๆ–นๅผ็ฌฆๅˆๅฝ“ๅœฐ่ฆๆฑ‚ไธŽๆณ•่ง„ใ€‚

Page 203: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

ไป‹็ป

ๆ•…้šœๆŽ’้™ค

201

็ปดๆŠค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆจกๆ‹Ÿไบบๅธธ่ง„ไฟๅ…ป

้ตไปŽไธ‹ๅˆ—ๆŒ‡็คบ๏ผŒไปฅ็ปดๆŒๆจกๆ‹ŸไบบๅŠๅ…ถ็ป„ไปถ็š„ๆœ€ไฝณๆ€ง่ƒฝๅ’Œไฝฟ็”จๅฏฟๅ‘ฝใ€‚

ๅธธ่ง„ไฟๅ…ป

ไธบไฟๆŒๆจกๆ‹Ÿไบบ็šฎ่‚คๅซ็”Ÿ๏ผŒไฝฟ็”จๅ‰่ฏทๆด—ๆ‰‹๏ผŒๅนถๅฐ†ๅ…ถ็ฝฎไบŽๆดๅ‡€่กจ้ข

ไน‹ไธŠใ€‚ๆŒชๅบฆๅปบ่ฎฎ๏ผš

โ€“ ๅœจๆจกๆ‹Ÿ็—…ไพ‹ๆœŸ้—ด๏ผŒไฝฉๆˆดๆ‰‹ๅฅ—ใ€‚้ฟๅ…ไฝฟ็”จๅฝฉ่‰ฒๅก‘ๆ–™ๆ‰‹ๅฅ—๏ผŒ

ๅ› ไธบๅฎƒไปฌๅฏ่ƒฝไผš่‡ดไฝฟๆจกๆ‹Ÿไบบ็šฎ่‚คๅ˜่‰ฒใ€‚

โ€“ ๅˆ‡ๅ‹ฟๅœจๆจกๆ‹Ÿไบบ้™„่ฟ‘ไฝฟ็”จๆฏกๅฐ–ๆ ‡่ฎฐ็ฌ”ใ€ๅขจๆฐด็ฌ”ใ€ไธ™้…ฎใ€็ข˜ๆˆ–

ๅ…ถไป–ๆŸ“่‰ฒ่ฏ็‰ฉใ€‚ๆณจๆ„ๅ‹ฟๅฐ†ๆจกๆ‹Ÿไบบๆ”พๅœจๆŠฅ็บธๆˆ–ๅฝฉ่‰ฒ็บธๅผ 

ไน‹ไธŠใ€‚ๆŸ“่‰ฒๅฏ่ƒฝๆ˜ฏๆฐธไน…ๆ€ง็š„ใ€‚

โ€“ ๆจกๆ‹Ÿไบบ็šฎ่‚คๅฏ็”จ่‚ฅ็š‚ๅ’Œๆธ…ๆฐด่ฟ›่กŒๆธ…ๆดใ€‚

ๅˆ‡ๅ‹ฟๅ› ไธบๆ— ๆณ•้€‚ๅฝ“ๆธ…ๆดๆฐ”้“่€Œ่ฏ•ๅ›พๅœจ่ฏฅๆจกๆ‹Ÿไบบ่บซไธŠๆ–ฝ็”จไธ‹ๅˆ—

ๆŠ€ๆœฏ๏ผš

โ€“ ๅฃๅฏนๅฃ๏ผๅฃๅฏน้ข็ฝฉๅนๆฐ”

โ€“ ๆณจๅ…ฅๆจกๆ‹Ÿๅ‚ฌๅๅ‰‚ๆˆ–ๆŠฝๅธ็”จๆถฒไฝ“

โ€“ ๅฆ‚ๆžœๅŸน่ฎญ็Žฏ่Š‚ไธญๆถ‰ๅŠๅˆฐไธบ้™่„‰ๆณจๅฐ„่‡‚ๆณจๅ…ฅๆถฒไฝ“๏ผŒ่ฏทๅœจ่ฏฅ่Š‚่ฏพๅŽ็ซ‹ๅณๆŽ’ๅนฒ่‡‚ๅ†…็š„ๆถฒไฝ“ใ€‚

โ€“ ไป…ไฝฟ็”จๆŒชๅบฆๆฐ”้“ๆถฆๆป‘ๅ‰‚ๅนถ่Š‚็œ็”จ้‡ใ€‚

โ€“ ๅ†ฒๆด—ใ€ๆธ…ๆดๅนถๅนฒ็‡ฅๆจกๆ‹Ÿไบบ็ป„ไปถๆจกๅ—ใ€‚

โ€“ ๅฐ†่บฏๅนฒ็šฎ่‚คๆŠ˜่ตท๏ผŒๅนถๅœจๅ…ถๅ†…ไพงๆถ‚ๆ“ฆ็ฒ‰ๆœซ๏ผŒไปฅๅ‡ๅฐ‘ๆ‘ฉๆ“ฆใ€‚ๅˆ‡ๅ‹ฟ

ๅฐ†็ฒ‰ๆœซๆ’’ๅœจๆจกๆ‹Ÿไบบ่ƒธ่…”ๅ†…ใ€‚

็Žฏๅขƒ

ๅœจๅฏ’ๅ†ทๆกไปถไธ‹๏ผŒ่ฏท็ญ‰ๅˆฐๆจกๆ‹Ÿไบบ่พพๅˆฐๅฎคๆธฉๅŽๅ†ๅฏๅŠจใ€‚

้ฟๅ…่ฟ‡็ƒญๅนถๅ‡ๅฐ‘็ฃจๆŸ๏ผš

โ€“ ๅฝ“ไฝฟ็”จๆธฉๅบฆ้ซ˜ไบŽ 40ยฐC ๆ—ถ๏ผŒๅง‹็ปˆ็ญ‰ๆจกๆ‹Ÿไบบๅ†ทๅดไธ‹ๆฅๅŽๅ†่ฟ›่กŒ

ไธ‹ไธ€ไธช่ฎญ็ปƒ็Žฏ่Š‚ใ€‚

โ€“ ๅœจๅบŠไธŠไฝฟ็”จๆ—ถ๏ผŒไธๅพ—ๅœจๆจกๆ‹Ÿไบบ่บซไธŠ่ฆ†็›–ๆฒ‰้‡็š„่ขซ่คฅ๏ผŒไปฅๅ…

ๅฆจ็ขๆจกๆ‹Ÿไบบ่ฟ›่กŒ็ƒญไผ ้€’ใ€‚

ๆจกๆ‹Ÿไบบๅธธ่ง„ๅค„็†

้‡‡ๅ–ไธ‹ๅˆ—้ข„้˜ฒๆŽชๆ–ฝ๏ผŒไปฅ้ฟๅ…้€ ๆˆไบบ่บซไผคๅฎณๆˆ–ไบงๅ“ๆŸๅ๏ผš

โ€“ ไธฅๆ ผๆŒ‰็…งๆœฌๆ–‡ไปถไธญ็š„ๆŒ‡็คบไธบๆจกๆ‹Ÿไบบๆณจๅ…ฅๆถฒไฝ“

โ€“ ๅœจๆ’ๅ…ฅไปปไฝ•ๅ™จๆขฐใ€ๅฏผ็ฎกๆˆ–ๆฐ”้“่ฃ…็ฝฎๅ‰๏ผŒ็”จๆ‰€ๆไพ›็š„ๆถฆๆป‘ๅ‰‚

ๆถฆๆป‘ๅฃ่…”ๆˆ–้ผป่…”ๆฐ”้“ใ€‚ๅŒๆ—ถ๏ผŒๅœจไฝฟ็”จๅ‰๏ผŒๆถฆๆป‘่ฟ™ไบ›ๅ™จๆขฐๅ’Œ

ๅฏผ็ฎกใ€‚

โ€“ ้€šๆฐ”่ฟ‡็จ‹ไธญ๏ผŒๅˆ‡ๅ‹ฟๅฐ†ๆฝฎๆนฟ็ฉบๆฐ”ๅผ•ๅ…ฅ็ณป็ปŸใ€‚

โ€“ ๅฆ‚ๆžœๆจกๆ‹Ÿไบบ็š„ๅ†…้ƒจ็ฎก้“ๅ’Œ็บฟ็ผ†ๆ–ญๅผ€๏ผŒๅˆ‡ๅ‹ฟไฝฟ็”จใ€‚

โ€“ ๅˆ‡ๅ‹ฟๅœจๆฝฎๆนฟๆกไปถไธ‹ๅœจๆˆทๅค–ไฝฟ็”จ SimJunior ๆจกๆ‹Ÿไบบ๏ผŒๅฆๅˆ™ๅฏ่ƒฝ

ไผšๅธฆๆฅ็”ตๅ‡ปๅฑ้™ฉๆˆ–ๆŸๅๆจกๆ‹Ÿไบบใ€‚

โ€“ ๅœจๆธฉๅบฆ่ถ…่ฟ‡ 35ยฐC ๆ—ถไฝฟ็”จ้™ค้ขคๅ™จๅฏ่ƒฝไผšๅฏผ่‡ด่ฟ‡็ƒญใ€‚

่ญฆๅ‘Š๏ผšๅˆ‡ๅ‹ฟๅœจๆจกๆ‹Ÿไบบ่บซไธŠไฝฟ็”จ่‡ชๅŠจ่ƒธ้ƒจๆŒ‰ๅŽ‹ๅ™จใ€‚

ๅฐๅฟƒไนณ่ƒถ๏ผšๆœฌๅ“ๅซๆœ‰ๅคฉ็„ถๆฉก่ƒถไนณ่ƒถ๏ผŒไธŽไบบไฝ“ๆŽฅ่งฆๅŽๅฏ่ƒฝ

ไผšๅผ•่ตท่ฟ‡ๆ•ๅๅบ”ใ€‚

้™ค้ขคๅฑๅฎณ ็”จๆˆทๅฏๅฏน SimJunior ่ฟ›่กŒ้™ค้ขคๆ“ไฝœใ€‚

็”จๆˆทๅฏๅœจ SimJunior ไธŠๅบ”็”จไผ ็ปŸ้™ค้ขคๅ™จใ€‚้™ค้ขค่ฟ‡็จ‹ไธญ๏ผŒ้™ค้ขคๅ™จ

ๅ’Œๆจกๆ‹Ÿไบบๅฏ่ƒฝไผšๅธฆๆฅ็”ตๅ‡ปๅฑ้™ฉใ€‚ๅœจๆจกๆ‹ŸไบบไธŠไฝฟ็”จ้™ค้ขคๅ™จๆ—ถ๏ผŒ

ๅฟ…้กป้ต็…งๆ‰€ๆœ‰ๆ ‡ๅ‡†็š„ๅฎ‰ๅ…จๆณจๆ„ไบ‹้กนใ€‚

โ€ข ้˜…่ฏปๅนถ้ตๅฎˆ้™ค้ขคๅ™จๅŠ็›ธๅ…ณ่ฎพๅค‡้™„ๅธฆ็š„ๆ‰€ๆœ‰ๅฎ‰ๅ…จๅŠๆ“ไฝœ่ฏดๆ˜Žใ€‚

โ€ข ้™ค้ขคๆ—ถ๏ผŒ่ฏท้ตไปŽ้™ค้ขคๆ–นๆกˆ๏ผŒ้ฟๅ…็ขฐ่งฆๅค–้ƒจๅžซ็‰‡ๅ’Œไปปไฝ•็”ตๆž

้ƒจไฝใ€‚ๆœ€ๅคง่ดŸ่ทไผ ้€’ๅฏ่พพ 300 ็„ฆ่€ณใ€‚

โ€ข ไธ้ตไปŽๅฎ‰ๅ…จๆŽชๆ–ฝๅฏ่ƒฝไผšๅฏผ่‡ดไบบ่บซไผคๅฎณๆˆ–ๆญปไบกใ€‚

ๅฆ‚้œ€ไบ†่งฃๆ›ดๅคšไฟกๆฏ๏ผŒ่ฏทๅ‚้˜…้™ค้ขคๅ™จ็š„ๅŽŸๅง‹็”จๆˆทๆ‰‹ๅ†Œใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ่ฟ›่กŒ้™ค้ขคๆ“ไฝœๆ—ถ๏ผŒ่ฏทไฝฟ็”จ้™ค้ขคๅ™จ่ฟžๆŽฅๅ™จๆˆ–ๅฎ‰่ฃ…ๅœจๆจกๆ‹Ÿไบบ

่ƒธ้ƒจไธŠ็š„้›ท็”ตๆฟใ€‚่ฏทๅ‹ฟไฝฟ็”จไธ“็”จไบŽๅฟƒ็”ตๅ›พ็›‘ๆŽง็š„ๅฟƒ็”ตๅ›พ่ฟž

ๆŽฅๅ™จใ€‚ๅœจๅฟƒ็”ตๅ›พ่ฟžๆŽฅๅ™จไธŠไฝฟ็”จ้™ค้ขคๆณ•ๅฐ†ไผšๆŸๅๆจกๆ‹Ÿไบบ็š„ๅ†…

้ƒจ็”ตๅญ่ฎพๅค‡๏ผŒๅฏ่ƒฝไผšๅผ•่ตทไบบไฝ“ๆŸไผคใ€‚

โ€“ ๅˆ‡ๅ‹ฟๅœจๆจกๆ‹Ÿไบบๅค„ไบŽๅ…ณๆœบ็Šถๆ€ๆˆ–่€…ๅœจๅ…ถๆ— ๆณ•ๆญฃๅธธๅทฅไฝœๆ—ถ็ป™ๆจก

ๆ‹Ÿไบบ้™ค้ขคใ€‚

ไป‹็ป

ๅ…่ดฃๅฃฐๆ˜Ž ๅˆฉ็”จ SimJunior ็—…ไบบๆจกๆ‹Ÿ็ณป็ปŸๅฏนไบบๅ‘˜่ฟ›่กŒ็š„ๅŸน่ฎญๅบ”ๅœจ็ป้€‚ๅฝ“ๅŸน

่ฎญ็š„ๆŠ€ๆœฏๆˆ–ๅŒป็–—ไบบๅ‘˜็š„็›‘็ฃไธ‹่ฟ›่กŒ๏ผŒ่€Œไธ”่ฏฅ็ญ‰ไบบๅ‘˜่ฟ˜ๅฟ…้กปไบ†่งฃ

่ฎญ็ปƒๅŽŸๅˆ™ๅ’Œๅ…ฌ่ฎค็š„ๅŒป็–—ๆ–นๆกˆใ€‚ๆ‰€ๆœ‰ๆจกๆ‹Ÿไบบๆˆ–ๅ…ถไป–่ฏฅ็ญ‰ๅŸน่ฎญ่ฃ…็ฝฎ

ๅœจ่งฃๅ‰–็‰นๆ€งๅ’Œ็”Ÿ็†ๅปบๆจกๆ–น้ข๏ผŒ้ƒฝๅฏ่ƒฝๅญ˜ๆœ‰็›ธไผผใ€ไธๅŒๅ’Œไธๅ‡†็กฎ

ไน‹ๅค„ใ€‚ๅ› ๆญค๏ผŒๆŒชๅบฆไธ่ƒฝไฟ่ฏๆ‰€ๆœ‰ๅŠŸ่ƒฝ้ƒฝๅฎŒๅ…จๅ‡†็กฎใ€‚

ๅ…จ็ƒไฟไฟฎ ่ฏทๅ‚้˜…ๆŒชๅบฆๅ…จ็ƒไฟไฟฎๆ‰‹ๅ†Œ๏ผŒๆˆ–่ฎฟ้—ฎ www.laerdal.com/cn/ใ€‚

ๅŽŸไบงๅ›ฝโ€”โ€”SimJunior ็”ฑ็พŽๅ›ฝๅˆถ้€ ใ€‚

Laerdal Medical P.O.Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 204: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

202

้™ค้ขคๆœŸ้—ด๏ผŒไธบ้˜ฒๆญข่ฟ‡็ƒญ็Žฐ่ฑก๏ผŒๅˆ‡ๅ‹ฟ่ถ…่ฟ‡ๆญค้ข‘็Ž‡๏ผšๅœจ 1 ๅˆ†้’Ÿๅฟƒ่‚บ

ๅค่‹ๆœฏๅŽ๏ผŒ็ดงๆŽฅ็€ 45 ็ง’ๅ†…่ฟ›่กŒไธ€่ฝฎ 3 ไธ‹็š„็”ตๅ‡ป้™ค้ขคใ€‚30 ๅˆ†้’Ÿ

ไน‹ๅŽ๏ผŒๅœๆญขๆ‰€ๆœ‰็”ตๅ‡ป่กŒไธบ่‡ณๅฐ‘ 15 ๅˆ†้’Ÿ๏ผŒๅ†ๅผ€ๅง‹ๆ–ฐไธ€่ฝฎ็”ตๅ‡ปใ€‚

ๅˆ‡ๅ‹ฟๅฐ†่ฟ™ไธช่ฟ‡็จ‹้‡ๅคๆ“ไฝœ 4 ๅฐๆ—ถไปฅไธŠใ€‚ๆญคๅค–๏ผŒ้™ค้ขคๅ™จๆฏๅˆ†้’Ÿๆ”พ

็”ตไธๅพ—่ถ…่ฟ‡ 2 x 300ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ้™ค้ขคๆœŸ้—ด๏ผŒๆจกๆ‹Ÿไบบไธๅพ—ไธŽๅฏผ็”ต่กจ้ขๆˆ–็‰ฉไฝ“ๆŽฅ่งฆใ€‚

โ€“ ้ฟๅ…ๅœจๆ˜“็‡ƒ็Žฏๅขƒไธญไฝฟ็”จใ€‚ไพ‹ๅฆ‚๏ผŒ้™ค้ขค่ฟ‡็จ‹ไธญ๏ผŒๅบ”้ฟๅ…ไฝฟ็”จ้ซ˜

ๆต“ๅบฆ็š„็บฏๆฐงใ€‚ๅœจๆจกๆ‹Ÿไบบ้™„่ฟ‘ไฝฟ็”จ้ซ˜ๆต“ๅบฆๆฐงๆฐ”ๆ—ถ๏ผŒ้กป็กฎไฟ้€š้ฃŽ

่‰ฏๅฅฝใ€‚

โ€“ ๆจกๆ‹Ÿไบบ็š„่บฏไฝ“ๅฟ…้กปๆ—ถๅˆปไฟๆŒๅนฒ็‡ฅใ€‚

โ€“ ๅœจ่ฟ›่กŒ้™ค้ขคไน‹ๅ‰๏ผŒ่ฎฉๆจกๆ‹Ÿไบบๅ…ˆ้€‚ๅบ”ไธ€ไธ‹ใ€‚ๆธฉๅบฆ็š„็ช็„ถๅ˜ๅŒ–ๅฏ

่ƒฝไผšไฝฟๅ†ทๅ‡็‰ฉ่š้›†ๅœจ็”ตๅญ็ป„ไปถไธŠ๏ผŒๅนถๅฏ่ƒฝๅธฆๆฅ็”ตๅ‡ปๅฑ้™ฉใ€‚

โ€“ ไธบ้˜ฒๆญข่บฏๅนฒ็šฎ่‚ค็”ตๆžๅ‡น้™ท๏ผŒๅˆ‡ๅ‹ฟไฝฟ็”จ็—…ไบบไธ“็”จ็š„ๅฏผ็”ตๅ‡่ƒถๆˆ–

ๅฏผ็”ต้™ค้ขคๅžซใ€‚

โ€“ ้™ค้ขค่ฟ‡็จ‹ไธญ๏ผŒ่ฟ‡ๅบฆ็”จๅŠ›ๅ‘ไธ‹ๆŒ‰้™ค้ขค่ฟžๆŽฅๅ™จไนŸๅฏ่ƒฝๅผ•่ตท็”ตๅผงๆ”พ

็”ตๅ’Œๅ‡น้™ทใ€‚

โ€“ ๅœจ่บฏๅนฒ็šฎ่‚คๆœชๅฐฑไฝ็š„ๆƒ…ๅ†ตไธ‹๏ผŒ่ฏทๅ‹ฟๅฏนๆจกๆ‹Ÿไบบ่ฟ›่กŒ้™ค้ขคๆ“ไฝœใ€‚

ๆœบๆขฐๆˆ–็”ตๆฐ”ๅฑๅฎณ ๅœจไธ‹ๅˆ—ๆƒ…ๅ†ตไธ‹๏ผŒ่ฏทๅ‹ฟไฝฟ็”จ SimJunior ๆจกๆ‹Ÿไบบ๏ผš

โ€“ ๅ››่‚ขๆœช้™„็€ๅœจ่บฏๅนฒไธŠ

โ€“ ็šฎ่‚ค่ฃ‚ๅผ€ๆˆ–ๆฒกๆœ‰้€‚ๅฝ“็ดงๅ›บ

โ€“ ๅ†…้ƒจๆˆ–ๅค–้ƒจ็บฟ็ผ†ใ€็ฎก้“ๆˆ–่ฟžๆŽฅๅ™จๆŸๅใ€‚

โ€“ ๆœ‰ๆถฒไฝ“ๆณ„ๆผๅˆฐๆจกๆ‹Ÿไบบๅ†…้ƒจๆˆ–่กจ้ข

โ€“ ๆœ‰ๅผ‚ๅธธๅฃฐ้Ÿณๆ็คบ็ฉบๆฐ”ๆณ„ๆผๆˆ–ๆœบๆขฐๆŸๅ

โ€“ ๆœ‰่ฟน่ฑก่กจๆ˜Žๅ‡บ็Žฐ็”ตๆฐ”ๆ•…้šœ๏ผŒไพ‹ๅฆ‚ๆจกๆ‹Ÿไบบๆ— ๅๅบ”ๆˆ–ๅผ‚ๅธธๆฐ”

ๅ‘ณๆˆ–็ƒŸ้›พ

่ญฆๅ‘Š๏ผš

โ€“ ้ฟๅ…ๅคน็—›ๅฑ้™ฉ๏ผๆ— ๅค–้ƒจ็šฎ่‚คๆ—ถ๏ผŒ่ฏทๅ‹ฟไฝฟ็”จๆจกๆ‹Ÿไบบใ€‚

็”ตๆฑ ไฝฟ็”จๅ’Œ็ปดๆŠค

โ€“ ่ฏทๅŠกๅฟ…ไฝฟ็”จ่Žทๅ‡†็”จไบŽ SimJuniorใ€Link Boxใ€SimPad ็”ตๆบ็š„็”ตๆฑ ใ€‚

โ€“ ็กฎไฟๆญฃ็กฎๅฎ‰่ฃ…็”ตๆฑ ใ€‚ไธๆญฃ็กฎๅœฐๆ’ๅ…ฅๅ’Œ่ฟžๆŽฅ็”ตๆฑ ๅฏ่ƒฝไผš้€ ๆˆ

็Ÿญ่ทฏใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ๆ นๆฎๅฝ“ๅœฐๆณ•่ง„ๅผƒ็ฝฎ็”ตๆฑ ใ€‚

โ€“ ๅค–้ƒจ็”ตๆฑ ๅ……็”ตๅ™จไป…ๅฏๅœจๅฎคๅ†…ไฝฟ็”จใ€‚

โ€“ ๆจกๆ‹Ÿไบบ็”ตๆฑ ไป…ๅบ”ๅœจ 0ยฐC ๅˆฐ 40ยฐC ็š„ๆธฉๅบฆๆกไปถไธ‹่ฟ›่กŒๅ……็”ต

โ€“ ๅˆ‡ๅ‹ฟไธๅฝ“ๅค„็†ใ€ๆ‹†ๅธๆˆ–ๅฐ่ฏ•ไฟฎ็†็”ตๆฑ ใ€‚ๅฆ‚ๆžœ็”ตๆฑ ๆœ‰ๆ˜Žๆ˜พ

ๆŸๅใ€ๆ•…้šœๆˆ–ๅค–่กจๅ‡บ็Žฐๆธ—ๆผ๏ผŒๅˆ‡ๅ‹ฟไฝฟ็”จใ€‚

โ€“ ่ฏทๆ ผๅค–ๅฐๅฟƒ๏ผŒไปฅ้ฟๅ…็›ดๆŽฅๆŽฅ่งฆ็”ตๆฐ”ใ€็ผ็ƒญๆˆ–ๅ†’็ƒŸ้ƒจไปถใ€‚

ไธ€ๆ—ฆ็”ตๆฑ ๅ‘็”Ÿๆณ„ๆผ๏ผŒๅœจๆ–ญๅฎšๅฎ‰ๅ…จ็š„ๆƒ…ๅ†ตไธ‹๏ผŒๆ–ญๅผ€็”ตๆฑ ่ฟžๆŽฅ๏ผŒ

ๅฐ†ๅ…ถๅ–ๅ‡บใ€‚

โ€“ ็”ตๆฑ ๆถฒไฝ“ๆšด้œฒๅœจ็ฉบๆฐ”ไธญไผšๅธฆๆฅ็ˆ†็‚ธๅฑ้™ฉใ€‚

โ€“ ๆฏ 30 ไธชๅ……็”ตๅ‘จๆœŸ๏ผŒๅœจๅ†ๆฌกๅ……็”ตไน‹ๅ‰ๆŠŠ็”ตๆฑ ๅฎŒๅ…จ่€—ๅฐฝใ€‚่‹ฅ่ฆ

ๅฏน็”ตๆฑ ่ฟ›่กŒๅฎŒๅ…จๆ”พ็”ต๏ผŒ่ฏทๅœจ็”ตๆฑ ไพ›็”ต็š„ๆƒ…ๅ†ตไธ‹่ฟ่กŒๆจกๆ‹Ÿไบบ๏ผŒ

็›ด่‡ณๅ…ถ่‡ชๅŠจๅ…ณๆœบใ€‚

โ€“ ไป…้™ๆ›ดๆขๆŒชๅบฆ SimJunior ็”ตๆฑ ใ€‚

ๅ‚จๅญ˜ๅ’Œ่ฟ่พ“

โ€“ ๅˆ‡ๅ‹ฟๅฐ†ๅ……ๆปก็”ต็š„็”ตๆฑ ๅญ˜ๆ”พ่ถ…่ฟ‡ไธ€ไธชๆœˆใ€‚

โ€“ ็ฉบ่ฟๆ—ถ๏ผŒๆจกๆ‹Ÿไบบ็”ตๆฑ ๅฏๆ”พ็ฝฎๅœจๆจกๆ‹Ÿไบบไธญ่ฟ่พ“ใ€‚

โ€“ ่‹ฅ่ฆ่ฟ่พ“ๅค‡็”จ็”ตๆฑ ๏ผŒ่ฏท่”็ณป่ˆช็ฉบๅ…ฌๅธ๏ผŒไบ†่งฃๆœ€ๆ–ฐ่ฟ่พ“ๆณ•่ง„ใ€‚

่ญฆๅ‘Š๏ผš

โ€“ ๆ”พ็ฝฎๅœจ่ฟ่พ“็ฎฑ้‡Œๆ—ถ๏ผŒSimJunior ๆจกๆ‹Ÿไบบๅ’Œ็ป„่ฃ…ไปถๅพˆ้‡ใ€‚ๅœจ่ฟ่พ“

ๅ’Œๅ‚จๅญ˜่ฟ‡็จ‹ไธญ๏ผŒ่ฏทๅง‹็ปˆ็กฎไฟ็‰ข็‰ขๅ›บๅฎš SimJunior๏ผŒไปŽ่€Œ้ฟๅ…้€ 

ๆˆไบบ่บซไผคๅฎณๆˆ–ๆŸๅไบงๅ“ใ€‚

ไป‹็ป

Page 205: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

ไป‹็ป

ๆ•…้šœๆŽ’้™ค

203

็ปดๆŠค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

้ชจๅ†…ๆณจๅฐ„่…ฟ

้ชจๅ†…ๆณจๅฐ„่…ฟ็Œๆณจๅฃ

SimJunior ๆจกๆ‹Ÿ็ณป็ปŸ

ๅณ่‡‚ๅฟƒ็”ตๅ›พ่ฟž

ๆŽฅๅ™จ

่ƒธ้ชจ้™ค้ขคๆฟ

้™่„‰ๆณจๅฐ„่‡‚

ๅณ่…ฟๅฟƒ็”ตๅ›พ่ฟž

ๆŽฅๅ™จ

่ƒธ้ชจ้™ค้ขคๆฟ

ๅค–้ƒจ็ฉบๆฐ”่ฟžๆŽฅ

ๆจกๆ‹Ÿไบบ็บฟ็ผ†๏ผˆ60 ้’ˆ๏ผ‰

ๅทฆ่‡‚ๅฟƒ็”ตๅ›พ่ฟž

ๆŽฅๅ™จ

่ก€ๅŽ‹ๆ‰‹่‡‚

ๅฟƒๅฐ–้™ค้ขคๆฟ

ๅทฆ่…ฟๅฟƒ็”ตๅ›พ่ฟž

ๆŽฅๅ™จ

ไป‹็ป

Page 206: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

204

SimJunior ๆจกๆ‹Ÿ็ณป็ปŸ SimJunior ๅฏๅธฎๅŠฉ่ฟ›่กŒๆ•‘็”ŸๆŠ€่ƒฝไบ’ๅŠจๅŸน่ฎญ๏ผŒๅนถๅฏๅฏนไธดๅบŠๅนฒ้ข„ใ€ๅฏผๅธˆ

ๆŽงๅˆถๅ’Œ้ข„็ผ–็จ‹็—…ไพ‹ๅšๅ‡บๅ“ๅบ”๏ผŒไปŽ่€Œไฝฟๅญฆๅ‘˜่ƒฝๅคŸๆœ‰ๆ•ˆ็ปƒไน ๅฆ‚ไฝ•่ฏŠ

ๆ–ญๅ’Œๆฒป็–—็—…ไบบใ€‚

SimJunior ๅ…ทๆœ‰่‡ชไธปๅ‘ผๅธใ€ๆฐ”้“ๆŽงๅˆถใ€่ฏญ้Ÿณใ€ๅ‘ๅฃฐใ€ๅฟƒ็”ตๅ›พๅ’Œๅ…ถ

ไป–ไธดๅบŠๅŠŸ่ƒฝ๏ผŒๆ˜ฏๅŠŸ่ƒฝๅฎŒๅค‡็š„ๅ„ฟ็ง‘ๆจกๆ‹Ÿ็ณป็ปŸใ€‚SimJunior ่ƒฝๅคŸ่กจ็Žฐ

ๅ‡บๅฏไพ›่ง‚ๅฏŸๅ’Œ่ฏ†ๅˆซ็š„ๅคงๅคšๆ•ฐ็”Ÿๅ‘ฝไฝ“ๅพ๏ผŒ่€Œ่ฟ™ไนŸไฝฟๅฏผๅธˆ่ƒฝๅคŸๆ นๆฎ

้€ผ็œŸ็š„ไธดๅบŠ็Šถๅ†ตๅฏนๅญฆๅ‘˜็š„ๆŠ€่ƒฝ่ฟ›่กŒ่ฏ„ไผฐใ€‚

SimJunior ๅŠŸ่ƒฝ

โ€“ ็œŸๅฎžๆฐ”้“๏ผŒๅฏๆจกๆ‹Ÿๅ›ฐ้šพๆฐ”้“็ฎก็†ใ€ๅฃ่…”ๅ’Œ้ผป่…”ๆ’็ฎก

โ€“ ่ฟ›่กŒๆ˜Žๆ˜พๅ‘ผๅธ

โ€“ ๅฟƒ่„ๅŠŸ่ƒฝ๏ผŒๅŒ…ๆ‹ฌ้™ค้ขคๅ’Œๅฟƒ่„ๅคๅพ‹

โ€“ ๅฏๆ›ดๆข็žณๅญ”๏ผˆๆญฃๅธธใ€ๆ•ฃๅคงๆˆ–็ผฉๅฐ๏ผ‰็š„็œผ็›

โ€“ ๆจกไปฟ็™ซ็—ซๅ‘ไฝœ๏ผŒ่ฟ›่กŒๆŠฝๆ

โ€“ ่ƒธ้ƒจๆŒ‰ๅŽ‹

โ€“ ๅ…ทๆœ‰่ก€็ฎก้€š่ทฏ

โ€“ ๅฏๅ‘ๅ‡บๆญฃๅธธๅ’Œๅผ‚ๅธธ็š„ๅฟƒ้Ÿณใ€ๅ‘ผๅธ้Ÿณๅ’Œ่‚ ้ธฃ้Ÿณ

โ€“ ๅฏไพๆฎ้ข„็ผ–็จ‹ไธ”็ป็กฎ่ฎค็š„็—…ไบบ็—…ไพ‹๏ผŒ่ฟ›่กŒ่‡ชๅŠจๆจกๆ‹ŸๆŽงๅˆถ

ๅฏไฝฟ็”จ SimPad ไธŠ็š„็—…ไพ‹ๆˆ–ไฝฟ็”จ LLEAP๏ผˆไธชไบบ็”ต่„‘๏ผ‰่‡ชๅŠจ่ฟ่กŒ

ๆจกๆ‹Ÿใ€‚็—…ไบบ็—…ๆƒ…็š„ๅ‘ๅฑ•ๆ˜ฏ้ข„ๅ…ˆ็ผ–็จ‹็š„๏ผŒๆ นๆฎๅ‚ไธŽ่€…็š„ๅนฒ้ข„๏ผŒ

ไผš่‡ชๅŠจๅ“ๅบ”ใ€‚

ๆ€ปๅฐบๅฏธ

้•ฟ๏ผๅฎฝ๏ผˆไป…ๆจกๆ‹Ÿไบบ๏ผ‰๏ผš120 ๅŽ˜็ฑณ x 42.5 ๅŽ˜็ฑณ

้‡้‡๏ผˆไป…ๆจกๆ‹Ÿไบบ)๏ผš11.36 ๅ…ฌๆ–ค

SimJunior ่กฃ็‰ฉ

SimJunior ้…ๆœ‰ๅฎšๅˆถ็š„ไธ“็”จ่กฃ็‰ฉ๏ผŒ่ฏฅ่กฃ็‰ฉ้‡‡็”จ Velcro ๅฐผ้พ™ๆญๆ‰ฃ๏ผŒ

ไพฟไบŽ็ฉฟ่„ฑใ€‚ๆธ…ๆด—่ฏดๆ˜Ž่ฏท่ง่กฃ็‰ฉไธŠ็š„ๆ ‡็ญพใ€‚

โ€“ ่กฌ่กซ

โ€“ ็Ÿญ่ฃค

โ€“ ๅนณ่ง’็Ÿญ่ฃค

ไธ€่ˆฌไธดๅบŠๅŠŸ่ƒฝ

ๆฐ”้“็‰น็‚น

ๅœจ่งฃๅ‰–ๅญฆไธŠ๏ผŒๆฐ”้“ๅฏ็ฒพ็กฎ่‡ณๆฐ”็ฎกใ€‚ๆฐ”้“ๅฏ้€š่ฟ‡ไธ‹ๅˆ—ๆ–นๅผ่ฟ›่กŒ

ๆŽงๅˆถ๏ผš

โ€“ ไปฐๅคดๆŠฌ้ขๆณ•

โ€“ ไธ‹้ขŒๅ…ณ่Š‚๏ผˆๅ…ณ่Š‚้“ฐๆŽฅ๏ผ‰ๅ‰ๆŽจ

โ€“ ็Žฏ็Šถ่ฝฏ้ชจๅŽ‹่ฟซๅ’Œๆ“ไฝœ

โ€“ ๆŠฝๅธ๏ผˆๅฃ่…”ๅ’Œ้ผปๅ’ฝ๏ผ‰

ๆจกๆ‹Ÿไบบๅฏ้€š่ฟ‡ๅธธ่ง„ๅ’Œ็ดงๆ€ฅๆ–นๅผ่ฟ›่กŒ้€šๆฐ”๏ผ›

โ€“ ้ข็ฝฉ้€šๆฐ”

โ€“ ็ปๅฃๆฐ”็ฎกๆ’็ฎก

โ€“ ็ป้ผปๆฐ”็ฎกๆ’็ฎก

ๅœจไฝฟ็”จๆฐ”้“่ฎพๅค‡ๅ‰๏ผŒ็”จๆŒชๅบฆๆฐ”้“ๆถฆๆป‘ๅ‰‚่ฟ›่กŒๆถฆๆป‘ใ€‚

ไธ‹ๅˆ—่ฎพๅค‡ๆˆ–ๆ–นๆณ•้€‚ไบŽๅ›บๅฎšๆจกๆ‹Ÿไบบ็š„ๆฐ”้“๏ผš

โ€“ ๅ–‰็ฝฉๆฐ”้“๏ผˆๅฐบๅฏธ 2.5 ๅท๏ผ‰

โ€“ ๆฐ”็ฎกๅ†…ๆ’็ฎก๏ผˆๅฐบๅฏธ ID 4.5 ็ฟป่พน๏ผŒ5.5 ไธ็ฟป่พน๏ผ‰

ๅปบ่ฎฎไฝฟ็”จๅฏๅปถๅฑ•็š„ๆŽขๅคดโ€”โ€”็กฎไฟๅ…ถไธไผš้•ฟ่ฟ‡ๆฐ”็ฎกๅ†…ๆ’็ฎกใ€‚

ไธ‹ๅˆ—ๆจกๆ‹Ÿไบบ็Šถๅ†ต่กจ็คบ็ฎกๅญๆ”พ็ฝฎไธๆญฃ็กฎ๏ผš

โ€“ ๅณ่พนไธปๅนฒๆ’็ฎกโ€”โ€”ๅ•่พน่ƒธ้ƒจ้ผ“่ตท

โ€“ ่…น้ƒจ่†จ่ƒ€

โ€“ ๆ— ่ƒธ้Ÿณ๏ผˆ่ฏทๅ‚้˜…โ€œๅ‘ผๅธโ€้ƒจๅˆ†๏ผ‰

็”จๆˆทๅฏๅฏนๆจกๆ‹Ÿไบบ็š„ๅŠŸ่ƒฝ่ฟ›่กŒ่ฎพ็ฝฎ๏ผŒ่ฟ›่€Œๅ‘ˆ็Žฐๅ‡บๅ„็งๆฐ”้“็—…ไพ‹๏ผš

โ€“ ่ˆŒๆฐด่‚ฟโ€”โ€”ๆญฃๅธธใ€ไธญ็ญ‰ใ€ๆœ€ๅคง็จ‹ๅบฆ

โ€“ ่‚บๅผ€ๆ”พๆˆ–้—ญๅˆ

ๅ‘ผๅธๅŠŸ่ƒฝ

SimJunior ่ƒฝๅคŸๆจกๆ‹Ÿ่‡ชไธปๅ‘ผๅธ๏ผŒไธ”ไผดๆœ‰ๆ˜Žๆ˜พ็š„่ƒธ้ƒจ่ตทไผ๏ผŒๅ‘ผๅธ้ข‘

็Ž‡ๅฏๅ˜ใ€‚ๅ‘ผๅธๆ˜ฏ็”ฑๆจกๆ‹Ÿไบบๅณๅคง่…ฟๅ†…็š„ไธ€ไธชๅฐ้—ญๅผๆฐ”ไฝ“ๅŽ‹็ผฉๆœบไบง

็”Ÿ็š„ใ€‚

โ€“ ไธคไพง่ƒธ้ƒจๅฏ้š่‡ชไธปๅ‘ผๅธ่ตทไผ

โ€“ ้€šๆฐ”่ฟ‡็จ‹ไธญ๏ผŒๅ•ไพง่ƒธ้ƒจไผš้šๅณไธปๆ”ฏๆ’็ฎก่ตทไผ

โ€“ ๅ•ไพงๅ’ŒๅŒไพง่‚บ้ƒจๅ‡ๆœ‰่‚บ้Ÿณ

โ€“ ๆญฃๅธธๅ’Œๅผ‚ๅธธ็š„ๅ‘ผๅธ้Ÿณ

โ€“ ๅ‘ผๅธ้ข‘็Ž‡ๅฏๅ˜๏ผˆๆฏๅˆ†้’Ÿ 0-60 ๆฌกๅ‘ผๅธ๏ผ‰

โ€“ ่ƒธๅ‰ๅฌ่ฏŠ้ƒจไฝ๏ผˆ4 ไธช๏ผ‰

ๅทฆ่‚บๅ’Œๅณ่‚บๅฏๅ•็‹ฌๆˆ–ๅŒๆ—ถๅ…ณ้—ญ๏ผŒไปฅๅฝขๆˆ้ƒจๅˆ†ๆˆ–ๅฎŒๅ…จๆฐ”้“ๆข—้˜ปใ€‚

SimJunior ๆจกๆ‹Ÿไบบ่ฟ˜ๅฏไธŽ่พ…ๅŠฉ้€šๆฐ”่ฃ…็ฝฎไธ€ๅŒไฝฟ็”จใ€‚

ๆณจๆ„๏ผš่‚บ้ƒจไธๅฏไธŽๅ‘ผๆฐ”ๆœซๆญฃๅŽ‹ (PEEP) ้˜€้—จไธ€่ตทไฝฟ็”จใ€‚

ไป‹็ป

Page 207: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

ไป‹็ป

ๆ•…้šœๆŽ’้™ค

205

็ปดๆŠค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

่ก€ๆถฒๅพช็ŽฏๅŠŸ่ƒฝ

ๅฟƒ่„๏ผš

โ€“ ๅคง้‡็š„ๅฟƒ็”ตๅ›พๅบ“๏ผŒ่„‰ๆ่Œƒๅ›ดๅœจ 0-200 ไน‹้—ด

โ€“ ๅฟƒ้Ÿณโ€”โ€”่ƒธๅ‰ไฝ็ฝฎ๏ผˆ1 ไธช๏ผ‰

โ€“ ๅฟƒ็”ตๅ›พๅฟƒๅพ‹็›‘ๆต‹๏ผˆ4 ๆŽฅๅคด๏ผŒ3 ๅฏผ่”ๅฟƒ็”ตๅ›พ๏ผ‰

โ€“ 12 ๅฏผ่”ๅฟƒ็”ตๅ›พๆ˜พ็คบๅฑ๏ผˆไป…้™ LLEAP๏ผ‰

โ€“ ่ตทๆ

โ€“ ๅˆฉ็”จๅฏๅ……็”ต้™ค้ขคๅ™จ่ฟ›่กŒ้™ค้ขคๅ’Œๅฟƒ่„ๅคๅพ‹

้™ค้ขค๏ผš

โ€“ ่‡ชๅŠจ่ฝฌๆขๆ‰€้œ€็š„็”ตๅ‡ปๆฌกๆ•ฐๅฏๅœจๆฏไธชๆจกๆ‹Ÿ็—…ไบบ็—…ไพ‹ไธญ่ฟ›่กŒ่ฎพ็ฝฎ

้™ค้ขค่žบๆŸฑ๏ผš

3 ๅฏผ่”ๅฟƒ็”ตๅ›พ่žบๆŸฑ๏ผš

่ก€ๅŽ‹ๅ’Œ่„‰ๆ๏ผš

โ€“ ่ก€ๅŽ‹็”ฑๆŸฏๆฐ้Ÿณๅฌ่ฏŠๆ‰‹ๅŠจๆต‹้‡

โ€“ ๅŒไพง้ขˆๅŠจ่„‰่„‰ๆ

โ€“ ไธญๅฟƒ่„‰ๆๅฏ่ฎพ็ฝฎไธบๆญฃๅธธใ€ๅผฑๅ’Œๆ— 

โ€“ ๆกกๅŠจ่„‰๏ผ่‚ฑๅŠจ่„‰่„‰ๆๅฏ่ฎพ็ฝฎไธบๆญฃๅธธใ€ๅผฑๅ’Œๆ— 

โ€“ ้ขˆๅŠจ่„‰ใ€่‚ฑๅŠจ่„‰ใ€ๆกกๅŠจ่„‰่„‰ๆๅฏไธŽ ECG ๅŒๆญฅ

โ€“ ่„‰ๆๅผบๅบฆๅฏ้š่ก€ๅŽ‹ๅ˜ๅŒ–

โ€“ ๆฃ€ๆต‹ๅ’Œ่ฎฐๅฝ•่„‰ๆ่งฆ่ฏŠ

ๅฟƒ่‚บๅค่‹ๆœฏๅŠŸ่ƒฝ

โ€“ ้ตไปŽ 2010 ๅนดๆŒ‡ๅ—

โ€“ ๆŒ‰ๅŽ‹ไผšไบง็”Ÿๆ˜Žๆ˜พ็š„่„‰ๆใ€่ก€ๅŽ‹ๆณขๅฝขไปฅๅŠๅฟƒ็”ตๅ›พๅ›พๅƒ

โ€“ ้€ผ็œŸ็š„ๆŒ‰ๅŽ‹ๆทฑๅบฆๅ’Œ้˜ปๅŠ›

โ€“ ๅฏๆฃ€ๆต‹ๅˆฐๆŒ‰ๅŽ‹ๆทฑๅบฆๅ’Œ้€Ÿ็Ž‡

่ก€็ฎกๅŠŸ่ƒฝ

้™่„‰้€š้“๏ผš

้™่„‰้€š้“ไฝไบŽๅณ่‡‚ๅ’Œๅณๆ‰‹ไธŠใ€‚็”จๆˆทๅฏๅฏน้™่„‰ๆณจๅฐ„่‡‚่ฟ›่กŒ่ฎพ็ฝฎ๏ผŒ

ไปฅไพฟๅœจไธ‹ๅˆ—้ƒจไฝ่ฟ›่กŒ้™่„‰ๆณจๅ…ฅใ€่พ“ๆณจๅ’ŒๆŽจๆณจ๏ผš

โ€“ ๅ‰่‡‚ๅ‘จๅ›ด้™่„‰

โ€“ ่‚˜ๅ‰็ชๅ’Œๆ‰‹่ƒŒ

้ชจๅ†…้€š้“ (IO)๏ผš

ๅฏ่ฟ›่กŒ้ชจๅ†…่พ“ๆณจ็š„้€š่ทฏไฝไบŽ๏ผš

โ€“ ่ƒซ้ชจ็ป“่Š‚๏ผˆๅณ๏ผ‰

โ€“ ๅ†…่ธ

ๆณจๆ„๏ผšSimJunior ๅนถๆ— ่‚Œๅ†… (IM) ๆณจๅฐ„้ƒจไฝใ€‚่ฏทๅ‹ฟๅฐ่ฏ•่ฟ›่กŒ

่‚Œๅ†…ๆณจๅฐ„ใ€‚

SimJunior ๅฃฐ้Ÿณ่ฎพ็ฝฎ SimJunior ๆ”ฏๆŒๅฏนๅฟƒ้Ÿณใ€่‚บ้Ÿณๅ’Œ่‚ ้ธฃ้Ÿณ่ฟ›่กŒๅคš้ƒจไฝๅฌ่ฏŠๅ’Œ่ฏ†ๅˆซใ€‚

ๆ‚จ่ฟ˜ๅฏๅœจ SimJunior ไธŠ่ฎพ็ฝฎ่ฏญ้Ÿณใ€‚

ๅฆ‚้œ€ไบ†่งฃๆ›ดๅคšๆœ‰ๅ…ณ SimJunior ๅฃฐ้Ÿณ่ฎพๅฎš็š„ไฟกๆฏ๏ผŒ่ฏทๅ‚่ง SimPad ไฝฟ็”จ

่ฏดๆ˜Žๆˆ– LLEAP ๅธฎๅŠฉๆ–‡ไปถใ€‚

ไป‹็ป

Page 208: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

206

Session Viewer ๅ’Œ SimView Server

Session Viewer ๅ’Œ SimView Server ไฝœไธบไธ€็งๅบ”็”จ็จ‹ๅบ๏ผŒ้™คไบ†ๆไพ›่ฏ„ไผฐ่ฎญ็ปƒ็Žฏ่Š‚็š„็•Œ้ข๏ผŒ่ฟ˜ๅฏๅœจๆจกๆ‹Ÿ่ฟ‡็จ‹ไธญ่ฎฐๅฝ•่ง†้ข‘ๅ’Œ็—…ไบบ็›‘ๆŠคไปชๆˆชๅฑใ€‚่ฎญ็ปƒ็Žฏ่Š‚็ป“ๆŸๅŽ๏ผŒๅฐ†ไผšไผ ่พ“ LLEAP ็”Ÿๆˆ็š„ๆ—ฅๅฟ—ๆ–‡ไปถ๏ผŒ ๅนถ็ป“ๅˆ Session Viewer ๆˆ– SimView Server ๆœๅŠกๅ™จไธญ็š„่ง†้ข‘ๆ–‡ไปถ่ฟ›่กŒ่ฏ„ไผฐใ€‚

Session Viewer ้€šๅธธๅฏๅœจ็”จไบŽ LLEAP ็š„ๅŒไธ€ๅฐ็”ต่„‘ไธŠ่ฟ›่กŒๆœฌๅœฐ่ฟ่กŒ๏ผŒSimView Server ๅˆ™ๅœจๆœฌๅœฐ็ฝ‘็ปœไธญไธ“็”จๆœๅŠกๅ™จไธŠ่ฟ่กŒใ€‚ๅˆๆฌกๅผ€ๅง‹ LLEAP ่ฟ‡็จ‹ไธญ๏ผŒ็ณป็ปŸไผšๆ็คบๆ‚จ้€‰ๆ‹ฉๆ‚จ็”ต่„‘ๆˆ–ๆœฌๅœฐ็ฝ‘็ปœไธญๅฏ็”จ็š„่ฏ„ไผฐๆŠฅๅ‘Š็ณป็ปŸใ€‚็จๅŽๅฐ†ไผš่ฟ›่กŒๆ›ดๆ”นใ€‚

ๅ…ถไป–ๅบ”็”จ็จ‹ๅบ

่ฟ˜ๆœ‰ๅ…ถไป–ไธŽๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ๅŒๆ—ถไฝฟ็”จ็š„็จ‹ๅบ๏ผŒไพ‹ๅฆ‚็”จไบŽๅค„็†็จ‹ๅบ่ฎธๅฏ่ฏ็š„ License Manager ไปฅๅŠ็”จไบŽๆ›ดๆ–ฐๆจกๆ‹Ÿไบบๅ›บไปถๆˆ–ๆŽ’้™ค็ฝ‘็ปœ้—ฎ้ข˜ๆ•…้šœ็š„ Simulator Firmware & Network Fixerใ€‚

SimDesignerSimDesigner ๆ˜ฏ็”จไบŽ่ฎพ็ฝฎๆ‚จ่‡ชๅทฑ็š„้ข„็ผ–็จ‹็—…ไพ‹็š„ๅบ”็”จ็จ‹ๅบใ€‚่ฏฅ็จ‹ๅบไนŸๅฏ็”จไบŽๅˆ†ๆžๅนถๆ‰“ๅฐๅ‡บ็—…ไพ‹็š„ๅ›พ็คบใ€‚

ๅฟ…้กปๅฎ‰่ฃ… SimDesigner๏ผŒๅฐ†ๆ—ง็‰ˆๅฏผๅธˆๅบ”็”จ็จ‹ๅบๆ–‡ไปถ่ฝฌๆขๆˆ LLEAP ๅ…ผๅฎน็š„ๆ–‡ไปถๆ ผๅผใ€‚

ๅธฎๅŠฉๆ–‡ๆกฃ

ๅฆ‚้œ€ไบ†่งฃๆ›ดๅคšๆœ‰ๅ…ณ LLEAP ่ฝฏไปถๅ’Œๅ…ถไป–ๅบ”็”จ็จ‹ๅบ็š„ไฟกๆฏ๏ผŒ่ฏทๅ‚่งๅธฎๅŠฉๆ–‡ๆกฃ๏ผš

1. ็‚นๅ‡ป Windows <ๅผ€ๅง‹> <ๆ‰€ๆœ‰็จ‹ๅบ>ใ€‚

2. ้€‰ๆ‹ฉ <Laerdal Simulation Home>ใ€‚

3. ้€‰ๆ‹ฉ <ๅธฎๅŠฉ>ใ€‚

็ฝ‘้กตไธ‹่ฝฝ

่ฏท่ฎฟ้—ฎ www.laerdal.com/downloads๏ผŒไธ‹่ฝฝๆœ€ๆ–ฐ็š„็”จๆˆทๆŒ‡ๅ—ๅ’Œ ่ฝฏไปถใ€‚

ๆจกๆ‹Ÿ่ฝฏไปถ

ๅฏผๅธˆไธชไบบ็”ต่„‘

ๅฏผๅธˆไธชไบบ็”ต่„‘ไฝฟ็”จ LLEAP ๆฅ็ฎก็†ๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ใ€‚LLEAP ไธŽๅ…ถไป–ๅฎž็”จๆจกๆ‹Ÿ็›ธๅ…ณๅบ”็”จ็จ‹ๅบไธ€ๆ ท๏ผŒๅฏไปฅไปŽ Laerdal Simulation Home ่ฎฟ้—ฎใ€‚

่ฝฏไปถ่ฎธๅฏ่ฏ ๅฏผๅธˆไธชไบบ็”ต่„‘ๅœจไปŽๆŒชๅบฆๅŒป็–—่ขซ่ฟๅ‡บๆ—ถ๏ผŒๅณๅทฒๅฎ‰่ฃ…ไบ†ไธ€ไธช้ข„ๅ…ˆๆฟ€ๆดป็š„ LLEAP ่ฎธๅฏ่ฏใ€‚

ๅ˜ๆ›ดๆˆ–ๆ›ดๆ–ฐ็”ต่„‘่ฝฏไปถ๏ผˆไพ‹ๅฆ‚ๆ–ฐ็กฌ็›˜ๆˆ–ไธปๆฟ๏ผ‰ๅฏ่ƒฝไผšๅฏผ่‡ด่ฎธๅฏ่ฏๆ— ๆ•ˆใ€‚่ฏท่”็ณปๆ‚จๅฝ“ๅœฐ็š„ๆŒชๅบฆๆ”ฏๆŒ๏ผŒไปฅ่Žทๅพ—ๆœ‰ๅ…ณ้‡ๆ–ฐๆฟ€ๆดป่ฎธๅฏ่ฏ็š„ๅธฎๅŠฉใ€‚

Laerdal Simulation HomeLaerdal Simulation Home ๆ˜ฏไธ€ไธชๅบ”็”จ็จ‹ๅบ๏ผŒๅฏๅœจๅ…ถไธญๆ‰พๅˆฐๅนถๅผ€ๅง‹ LLEAP ๅ’Œๅ…ถไป–ไธŽ็—…ไบบๆจกๆ‹Ÿๆœ‰ๅ…ณ็š„ๆŒชๅบฆ็จ‹ๅบใ€‚ไนŸๅฏไปฅไปŽ่ฟ™้‡Œๆ‰“ๅผ€ๅธฎๅŠฉๆ–‡ไปถใ€‚Laerdal Simulation Home ไฝไบŽ Windows ๅผ€ๅง‹่œๅ•ไธ‹็š„ๆŒชๅบฆๅŒป็–—ๆ–‡ไปถๅคนไธญ (Windows 7)ใ€‚

ๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ไธญๆ‰€ไฝฟ็”จ็š„่ฝฏไปถๅฏๅˆ†ไธบไปฅไธ‹ๅ‡ ็งไธป่ฆๅบ”็”จ็จ‹ๅบ๏ผš

โ€“ LLEAP (Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server ๆˆ– Session Viewer

ๆญคๅค–๏ผŒSimDesigner ๅ’Œๅ…ถไป–ๅบ”็”จ็จ‹ๅบ็”จไบŽ่ฎพ่ฎกๆˆ–ๅ‡†ๅค‡ๆจกๆ‹Ÿใ€‚

LLEAPLaerdal Learning Application (LLEAP) ๆ˜ฏๅฏผๅธˆ็š„ๅบ”็”จ็จ‹ๅบ๏ผŒๅฏๅœจๅ…ถไธญ่ฟ่กŒใ€ๆŽงๅˆถๅ’Œ็›‘ๆต‹ๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ใ€‚LLEAP ๅฏไปฅ่‡ชๅŠจๆˆ–ๆ‰‹ๅŠจๆจกๅผ่ฟ›่กŒๆ“ไฝœใ€‚่‡ชๅŠจๆจกๅผ็”จไบŽ้ข„็ผ–็จ‹็š„็—…ไพ‹๏ผŒ่€Œๆ‰‹ๅŠจๆ“ไฝœๅ…่ฎธๅฏผๅธˆๅฎŒๅ…จๆ‰‹ๅŠจๆŽงๅˆถๆจกๆ‹Ÿ่ฎญ็ปƒ็Žฏ่Š‚ใ€‚ๅœจๆ‰‹ๅŠจๆจกๅผไธ‹่ฟ่กŒๆจกๆ‹ŸๅŸน่ฎญ้€šๅธธ้œ€่ฆไธ€ไบ›ๅŒป็–—ไธ“ไธš็Ÿฅ่ฏ†๏ผŒไปฅๅˆ›ๅปบๆœ‰ๆ•ˆ็š„ไธดๅบŠๆจกๆ‹Ÿใ€‚

Voice Conference Application (VCA)ๅฆ‚่ฆๅœจๆจกๆ‹Ÿ่ฟ‡็จ‹ไธญๅ‘้€ๆ‰€ๆœ‰่ฏญ้Ÿณ๏ผŒ้œ€่ฆไฝฟ็”จ VCA ่ฝฏไปถใ€‚ๅฎƒๅ…่ฎธๅฏผๅธˆๅœจ่ฎญ็ปƒ็Žฏ่Š‚ไธญ้€š่ฟ‡ๆจกๆ‹Ÿไบบ่ฟ›่กŒ้€šไฟกใ€‚VCA ไนŸๅฏ็”จไบŽๅฏผๅธˆไน‹้—ดๅœจ็ฝ‘็ปœไธŠ็š„้€šไฟก๏ผŒๅนถไธ”ๅˆ›ๅปบๅชๆœ‰ไผšๅ‘˜ๆ‰ๅฏ้€š่ฏๅ’Œๅฌๅ–็š„็‹ฌ็ซ‹้€š้“ใ€‚

Patient MonitorPatient Monitor ๅบ”็”จ็จ‹ๅบๆจกๆ‹ŸๅŒป้™ขไธญๅ…ธๅž‹็š„็—…ไบบ็›‘ๆŠคไปชใ€‚ๅฎƒๆ˜ฏๅญฆๅ‘˜็š„ๆŽงๅˆถๅฐ๏ผŒๅฏ็”ฑๅฏผๅธˆๅ’Œๅญฆๅ‘˜้€š่ฟ‡ๅฑๅน•ไธŠ็š„่งฆๆ‘ธ่œๅ•่ฟ›่กŒ่ฎพๅฎšๅ’ŒๆŽงๅˆถใ€‚

Page 209: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

207

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆจกๆ‹Ÿๅ‡†ๅค‡ๅทฅไฝœ ๅ‡†ๅค‡ๅฅฝ SimJunior ๆจกๆ‹ŸไบบๅŠ่ฎพ็ฝฎๅฅฝๆ‰€ๆœ‰้€‚็”จ็š„ไบคไบ’ๅผ่ฎพๅค‡

๏ผˆSimPad ๆˆ–ๅฏผๅธˆไธชไบบ็”ต่„‘ๅ’Œ็—…ไบบ็›‘ๆŠคไปช๏ผ‰๏ผŒๅนถๅšๅฅฝๅค‡็”จๅ‡†

ๅค‡ๅŽ๏ผŒๅœจ SimJunior ๅ‡†ๅค‡่ฟ่กŒๆจกๆ‹Ÿไน‹ๅ‰๏ผŒๅฏ่ƒฝ้œ€่ฆๆ‰ง่กŒๆœ€็ปˆ

ๅ‡†ๅค‡ๅทฅไฝœใ€‚

ๆœ€็ปˆๆจกๆ‹Ÿๅ‡†ๅค‡ๅŒ…ๆ‹ฌไปฅไธ‹ๆดปๅŠจ๏ผš

โ€ข ๅ‡†ๅค‡้ชจๅ†…ๆณจๅฐ„่…ฟ

โ€ข ๆณจๅฐ„้™ๆณจๆถฒไฝ“

โ€ข ๆŽ’ๅนฒๅคšไฝ™็š„้™ๆณจๆถฒไฝ“

โ€ข ๆธ…ๆด—้™่„‰ๆณจๅฐ„่‡‚

โ€ข ่ฟžๆŽฅ้™ค้ขค้€‚้…ๅ™จๆฟ

โ€ข ่ฟžๆŽฅ่ก€ๅŽ‹่ข–ๅธฆ

โ€ข ๆ›ดๆข็žณๅญ”

โ€ข ่ฟžๆŽฅๅค–้ƒจๅŽ‹็ผฉๆœบ

โ€ข ๆ›ดๆ”นๅ†…้ƒจๅŽ‹็ผฉๆœบ็š„่ฎพ็ฝฎ

ๅ‡†ๅค‡้ชจๅ†…ๆณจๅฐ„่…ฟ ๆจกๆ‹Ÿไบบ็š„ๅณ่…ฟ่ฎพ่ฎก็”จไบŽ็ปƒไน ้ชจๅ†…ๆณจๅฐ„ๆŠ€่ƒฝใ€‚ๅณ่…ฟ่งฃๅ‰–ๆจกๅž‹ๅŒ…ๆ‹ฌ

่†็›–ใ€่ƒซ้ชจใ€่ƒซ้ชจ็ป“่Š‚้ƒจไฝๅ’Œๅ†…่ธ้ƒจไฝใ€‚ๅณ่…ฟๅธฆๆœ‰้™่„‰็ฎก้“ๅ’Œ

ไธ€ไธช้™่„‰ๆณจๅฐ„่ข‹๏ผŒ็”จไบŽๅœจ่พ“ๆณจๆ—ถไฝœไธบๅฎนๅ™จใ€‚

ๆ‰€้œ€็š„ๅ…ถไป–่ฎพๅค‡๏ผš

โ€ข ้™่„‰ๆณจๅฐ„่ข‹ๅ’Œ้™่„‰็ป™่ฏ่ฃ…็ฝฎ

โ€ข ๆจกๆ‹Ÿ่ก€ๆถฒๆต“็ผฉๆถฒ

โ€ข 35 cc ๆณจๅฐ„ๅ™จๅ’Œ 16 ๅท้ชจๅ†…้’ˆๅคด

็Œๆณจ้ชจๅ†…ๆณจๅฐ„่…ฟๅนถๅšๅฅฝๅค‡็”จๅ‡†ๅค‡๏ผš

1. ๅž‚็›ดๆŠฌ้ซ˜่…ฟใ€‚

2. ๆ‰“ๅผ€่„šๅŽ่ทŸ็š„ๅกžๅญใ€‚

3. ไฝฟ็”จๆณจๅฐ„ๅ™จๅœจ้ชจๅ†…็Œๆณจ็บฆ 240 ่‡ณ 250 cc ๆจกๆ‹Ÿ่ก€ๆถฒใ€‚

4. ่ฟžๆŽฅๅทฒ่ฟžๆŽฅ่‡ณ้™่„‰ๅ‚จๅญ˜่ข‹็š„็ฎก้“ใ€‚๏ผˆ่ง†ไนŽ้œ€่ฆไฝฟ็”จ่พŠๅคนๆ‰“ๅผ€

ๆˆ–ๅ…ณ้—ญ่ฏฅ็ฎก็บฟ๏ผŒไปฅๅ‡่ฝปๅŽ‹ๅŠ›็ดฏ็งฏใ€‚๏ผ‰

5. ๅฐๅ ตๆตๅ…ฅๅ‚จๅญ˜่ข‹็š„็ฎก้“๏ผŒไปฅไฝฟๆจกๆ‹Ÿ่ก€ๆถฒไฟ็•™ๅœจ้ชจๅ†…ไพ›ๆŠฝๅธใ€‚

6. ๅ‚จๅญ˜่ข‹ๆณจๆปกๅŽ๏ผŒๅœๆญข่พ“ๆณจ๏ผŒๅนถ็”จ็ฉบ่ข‹ๅญๆ›ฟๆขใ€‚

ๅ‚จๅญ˜ๆจกๆ‹Ÿไบบไน‹ๅ‰๏ผš

โ€“ ไปŽ่ถณ้ƒจๅˆ†็ฆป้™่„‰็ฎก็บฟๅ’Œๅฎนๅ™จ

โ€“ ่ฎฉๆ‰€ๆœ‰ๆถฒไฝ“ๆŽ’ๅนฒ

โ€“ ๆ‹”ไธ‹ๅ‚จๅญ˜่…ฟๅกžๅญ๏ผŒ่ฎฉๅฎƒ้ฃŽๅนฒ

ๆณจๆ„๏ผšๅˆ‡ๅ‹ฟไฝฟ็”จ็›ๆฐดใ€‚็›ๆฐดๅฏ่ƒฝๅฏผ่‡ด่…ฟๅ˜่‰ฒใ€‚ไฝฟ็”จ่’ธ้ฆๆˆ–ๅŽป็ฆปๅญๆฐด๏ผŒ้ฟๅ…็ดฏ็งฏ็Ÿฟ็‰ฉ่ดจใ€‚

ๆณจๅฐ„้™ๆณจๆถฒไฝ“

ๅณ้™่„‰ๆณจๅฐ„่‡‚ๆ”ฏๆŒ่ฟ›่กŒๅ‰่‡‚ๅ‘จๅ›ด้™่„‰ใ€่‚˜ๅ‰็ชๅ’Œๆ‰‹่ƒŒ้™่„‰

็ป™่ฏใ€้™่„‰ๆณจๅ…ฅใ€่พ“ๆณจๅ’ŒๆŽจๆณจๅŸน่ฎญใ€‚

ไฝฟ็”จ 20 ๅˆฐ 22 ๅท้’ˆๅคด่ฟ›่กŒ้™่„‰ๆณจๅฐ„ๆจกๆ‹Ÿใ€‚ไธบ้˜ฒๆญขๅ ตๅกž้™่„‰็ณป็ปŸ๏ผŒ

่ฏทไป…ไฝฟ็”จ่’ธ้ฆๆˆ–ๅŽป็ฆปๅญๆฐดๆจกๆ‹Ÿ้™่„‰ๆณจๅฐ„่ฏ็‰ฉใ€‚

ๆจกๆ‹Ÿไบบ่ฎพๅฎš

Page 210: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

208

ๆŽ’ๅนฒๅคšไฝ™็š„้™ๆณจๆถฒไฝ“

้™ๆณจๆถฒไฝ“็ณป็ปŸๆ˜ฏไธ€ไธชๅผ€ๆ”พ็š„็ณป็ปŸใ€‚้™ๆณจๆถฒไฝ“ๅœจ็ป™่ฏ่ฟ‡็จ‹ไธญไผš่ขซ

ๆŽ’ๅนฒใ€‚

ๅœจๆฏๆฌก่ฎญ็ปƒ็Žฏ่Š‚ไน‹ๅ‰๏ผš

1. ๅฐ†้™่„‰ๆบขๆต็ฎก๏ผˆๅœจๆจกๆ‹Ÿไบบ็š„ๅณ่‡‚ไธŠ๏ผ‰่ฟžๆŽฅ่‡ณไธ€ไธชๆบขๆตๅฎนๅ™จ

๏ผˆไพ‹ๅฆ‚้™่„‰ๆณจๅฐ„่ข‹๏ผ‰ใ€‚

2. ๆจกๆ‹ŸๆœŸ้—ด๏ผŒๅ…่ฎธๅคšไฝ™็š„ๆถฒไฝ“ๆŽ’ๅ…ฅไธ€ไธชๅฎนๅ™จ้‡Œใ€‚

ๆธ…ๆด—้™่„‰ๆณจๅฐ„่‡‚

ๅœจๆฏๆฌก่ฎญ็ปƒ็Žฏ่Š‚ๅŽๆˆ–ไฝฟ็”จๅฝ“ๆ—ฅ๏ผŒ็”จ 60% ็š„ๅผ‚ไธ™้†‡ๆˆ– 70% ็š„ไน™้†‡

ๅ†ฒๆด—้™่„‰ๆณจๅฐ„่‡‚๏ผŒไปฅๆธ…ๆด้™่„‰ๆณจๅฐ„่‡‚ใ€‚

ๅฎ‰่ฃ…้™ค้ขค้€‚้…ๅ™จๆฟ

ๆจกๆ‹Ÿไบบ่บฏๅนฒไธŠ้…ๆœ‰ไธคไธช่žบๆŸฑ่ฟžๆŽฅๅ™จ๏ผŒไปฅไพ›้™ค้ขคๅ™จ็”ต็ผ†ไฝฟ็”จใ€‚

ๅœจๅฐ่ฏ•้™ค้ขคไน‹ๅ‰๏ผŒๆ‚จๅฟ…้กปๆ—‹ๆพๅนถๅ–ไธ‹้™ค้ขคๅ™จ่žบๆ “ใ€‚

ๆจกๆ‹Ÿไบบ้…ๅค‡ไธคไธช้™ค้ขค้€‚้…ๅ™จๆฟใ€‚ๅฐ†ๅธฆ็”ต็š„้™ค้ขคๅ™จไธŽ้™ค้ขคๅžซไธ€่ตทไฝฟ

็”จไน‹ๅ‰๏ผŒๅฟ…้กปๅฎ‰่ฃ…ๅฅฝ้™ค้ขค้€‚้…ๅ™จๆฟใ€‚ๅฐ†ๅžซๆฟ็‰ขๅ›บๅœฐๆ—‹็ดงๅˆฐไฝใ€‚

้™ค้ขคๆœŸ้—ด

ๅฏๅœจ SimJunior ไธŠๅบ”็”จไผ ็ปŸ้™ค้ขคๅ™จ๏ผˆๆœชๅŒ…ๅซๅœจๆœฌไบงๅ“ไธญ๏ผ‰ใ€‚ๅœจ็Žฐ

ๅœบ้™ค้ขค่ฟ‡็จ‹ไธญ๏ผŒ้™ค้ขคๅ™จๅ’Œๆจกๆ‹Ÿไบบๅฏ่ƒฝ้€ ๆˆ็”ตๅ‡ปๅฑ้™ฉใ€‚ๅœจๆจกๆ‹Ÿไบบ

ไธŠไฝฟ็”จ้™ค้ขคๅ™จๆ—ถ๏ผŒๅฟ…้กป้ต็…งๆ‰€ๆœ‰ๆ ‡ๅ‡†็š„ๅฎ‰ๅ…จๆณจๆ„ไบ‹้กนใ€‚

ๆณจๆ„๏ผš้™ค้ขค่ฟ‡็จ‹ไธญ๏ผŒๆจกๆ‹ŸไบบไธๅฏๆŽฅ่งฆๅˆฐๅฏผ็”ต่กจ้ขๆˆ–็‰ฉไฝ“ใ€‚

่ญฆๅ‘Š:

โ€“ ้™ค้ขคไป…ๅฏๅœจ้™ค้ขคๅ™จ่ฟžๆŽฅๅ™จไธŠ่ฟ›่กŒใ€‚

โ€“ ๅœจ่บฏๅนฒ็šฎ่‚คไฝ็ฝฎไธ้€‚ๅฝ“็š„ๆƒ…ๅ†ตไธ‹๏ผŒ่ฏทๅ‹ฟๅฏนๆจกๆ‹Ÿไบบ่ฟ›่กŒ้™ค้ขค

ๆ“ไฝœใ€‚

่ฟžๆŽฅ่ก€ๅŽ‹่ข–ๅธฆ

ๆจกๆ‹Ÿไบบ้…ๆœ‰ไธ€ไธชๅฎšๅˆถ็š„่ก€ๅŽ‹่ข–ๅธฆใ€‚ๅœจไฝฟ็”จๅ‰๏ผŒๅฐ†็ฎกๅญ่ฟžๆŽฅ่‡ณ

ๆŽฅ็บฟ็›’ๅŽ้ข็š„็™ฝ่‰ฒ่ก€ๅŽ‹่ฟžๆŽฅๅ™จไธŠใ€‚

ๆณจๆ„๏ผšๆจกๆ‹Ÿไบบ็š„่ก€ๅŽ‹ๆ‰ฌๅฃฐๅ™จไฝไบŽๅทฆ่‚˜ๅ‰็ชๅค„๏ผˆไธ‹ๅ›พ็”ปๅœˆ

ๅŒบๅŸŸ๏ผ‰ใ€‚ๆกกๅŠจ่„‰ๅ’Œ่‚ฑๅŠจ่„‰่„‰ๆไฝไบŽ็ŸฉๅฝขๅŒบๅŸŸใ€‚

ๆ กๅ‡† LLEAP ไธญ็š„่ก€ๅŽ‹่ข–ๅธฆ

1. ไปŽ่œๅ•ไธญ้€‰ๆ‹ฉ <ๅทฅๅ…ท>ใ€‚

2. ไปŽๅทฅๅ…ท่œๅ•ไธญ้€‰ๆ‹ฉ <ๆจกๆ‹Ÿไบบ่ฎพๅฎš>ใ€‚

3. ไปŽๅญ่œๅ•ไธญ้€‰ๆ‹ฉ <ๆ กๅ‡†่ก€ๅŽ‹>ใ€‚

4. ้ต็…งๅฑๅน•ไธŠ็š„ๅ‘ๅฏผๆŒ‡็คบๆ‰ง่กŒๆ กๅ‡†ใ€‚

ๆ กๅ‡† SimPad ไธญ็š„่ก€ๅŽ‹่ข–ๅธฆ

1. ไปŽ่œๅ•ไธญ้€‰ๆ‹ฉ <ๆ กๅ‡†>ใ€‚

2. ไปŽไธ‹ๆ‹‰่œๅ•ไธญ้€‰ๆ‹ฉ <ๆ กๅ‡†่ก€ๅŽ‹>ใ€‚

3. ้ต็…งๅฑๅน•ไธŠ็š„ๅ‘ๅฏผๆŒ‡็คบๆ‰ง่กŒๆ กๅ‡†ใ€‚

ๆจกๆ‹Ÿไบบ่ฎพๅฎš

Page 211: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

209

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆ›ดๆข็žณๅญ”

SimJunior ้…ๆœ‰ๅทฒ็ปๅฎ‰่ฃ…ๅœจ็œผๅ†…็š„ๆญฃๅธธ็žณๅญ”ใ€‚SimJunior ้…ๆœ‰ๅซ

ๅก‘ๆ–™็žณๅญ”ๆ’ๅ…ฅ็‰ฉ๏ผˆ็ผฉๅฐๅ’Œๆ•ฃๅคง๏ผ‰็š„ๅ•็‹ฌๅฅ—ไปถใ€‚

่‹ฅ่ฆๆ›ดๆข็žณๅญ”๏ผš

1. ๅฐๅฟƒๅœฐๆŽฐๅผ€็œผ็‘๏ผŒๆณจๆ„ไธ่ฆๆ’•็ ดๆจกๆ‹Ÿไบบ็š„่„ธ้ƒจ็šฎ่‚คใ€‚

2. ไฝฟ็”จไธŽๅฅ—ไปถไธ€่ตทๆไพ›็š„ๅธๆฏๅทฅๅ…ทๆˆ–็”จๆ‚จ็š„ๆŒ‡็”ฒ่พน็ผ˜๏ผŒๅฐๅฟƒ

ๅœฐไปŽ็œผๅ†…ๅ–ๅ‡บ็žณๅญ”ใ€‚

3. ไฝฟ็”จๅธๆฏๅทฅๅ…ทๆˆ–้€š่ฟ‡่ฝป่ฝปๆŒ‰ๅŽ‹ๅˆฐไฝ๏ผŒๅฐ†็žณๅญ”ๆ›ดๆขๆˆๆ‰€้œ€็š„

ๆ’ๅ…ฅ็‰ฉใ€‚

ไฝฟ็”จๅค–้ƒจๅŽ‹็ผฉๆœบ ๅค–้ƒจๅŽ‹็ผฉๆœบ่ฟžๆŽฅ่‡ณไฝไบŽๆจกๆ‹Ÿไบบๅณ่พน็š„็บฟ็ผ†ๆŸๅ‡บๅฃๅค„็š„ๅนฒๅ‡€็ฎกๅญใ€‚

ไฝฟ็”จๅค–้ƒจๅŽ‹็ผฉๆœบๆ—ถ๏ผŒๆ‚จๅฏไปฅไปŽ SimPad ๆˆ– LLEAP ๅ…ณ้—ญๅค–้ƒจๅŽ‹็ผฉๆœบใ€‚

ๅฆ‚้œ€ไบ†่งฃๆœ‰ๅ…ณๅค–้ƒจๅŽ‹็ผฉๆœบๅ’Œ่ฐƒๆ•ดๅ™จ้ขๆฟไธŽ SimJunior ็š„ๅ…ผๅฎนๆ€ง็š„

ๆ›ดๅคšไฟกๆฏ๏ผŒ่ฏท่”็ณปๆ‚จๅฝ“ๅœฐ็š„ๆŒชๅบฆไปฃ่กจใ€‚

ๆ‰“ๅผ€ๆˆ–ๅ…ณ้—ญ SimPad ไธญ็š„ๅ†…้ƒจๅŽ‹็ผฉๆœบ

1. ๅผ€ๅง‹ <ๆ‰‹ๅŠจๆจกๅผ>๏ผŒ้€‰ๆ‹ฉไธ€ไธชไธป้ข˜ๅนถๅผ€ๅง‹่ฎญ็ปƒ็Žฏ่Š‚ใ€‚

2. ไปŽๅบ•้ƒจ่œๅ•ไธญ้€‰ๆ‹ฉ <ๅ…ถไป–>ใ€‚

3. ไปŽๅญ่œๅ•ไธญ้€‰ๆ‹ฉ <ๅŽ‹็ผฉๆœบ>ใ€‚

4. ๅœจๅฏน่ฏๆก†ไธญ่ฟ›่กŒๆ‰€้œ€ๆ›ดๆ”นๅนถ็‚นๅ‡ป็กฎๅฎšใ€‚

ๆ‰“ๅผ€ๆˆ–ๅ…ณ้—ญ LLEAP ไธญ็š„ๅ†…้ƒจๅŽ‹็ผฉๆœบ

1. ไปŽ่œๅ•ไธญ้€‰ๆ‹ฉ <ๅทฅๅ…ท>ใ€‚

2. ไปŽๅทฅๅ…ท่œๅ•ไธญ้€‰ๆ‹ฉ <ๆจกๆ‹Ÿไบบ่ฎพๅฎš>ใ€‚

3. ไปŽๅญ่œๅ•ไธญ้€‰ๆ‹ฉ <ๅ†…้ƒจๅŽ‹็ผฉๆœบ>ใ€‚

4. ๅœจๅฏน่ฏๆก†ไธญ่ฟ›่กŒๆ‰€้œ€ๆ›ดๆ”นๅนถ็‚นๅ‡ป็กฎๅฎšใ€‚

ๆจกๆ‹Ÿไบบ่ฎพๅฎš

Page 212: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

210

ๆณจๆ„๏ผšๆœ‰ๅ…ณๅค‡ไปถ็š„ไฟกๆฏ๏ผŒ่ฏทๅ‚่งไธ‹ๅˆ—้ƒจๅˆ†๏ผšๅค‡ไปถๅ’Œ้…ไปถใ€‚

ๅญ˜ๆ”พๆˆ–่ฟ่พ“ไน‹ๅ‰

โ€“ ็”จ 60% ็š„ๅผ‚ไธ™้†‡ๆˆ– 70% ็š„ไน™้†‡ๅ†ฒๆด—้™่„‰ๆณจๅฐ„่‡‚ใ€‚ๆ‰“ๅผ€ๆจกๆ‹Ÿ

ไบบๅณ่„šๅบ•้ƒจ็š„ๆŽ’ๆถฒ้˜€

ๆฏๆฌกๆจกๆ‹ŸๅŸน่ฎญ็Žฏ่Š‚ไน‹ๅŽ็š„็ปดๆŠค

ไธบ็กฎไฟ SimJunior ๆจกๆ‹Ÿไบบ็š„ไฝฟ็”จๅฏฟๅ‘ฝ๏ผŒ้œ€้‡‡ๅ–ไปฅไธ‹้ข„้˜ฒๆŽชๆ–ฝใ€‚

โ€“ ๆ–ญๅผ€ SimPadใ€ๆŽฅ็บฟ็›’ๅŠไธชไบบ็”ต่„‘็š„็”ตๆบ

โ€“ ๅฟ…่ฆๆ—ถไธบ็”ตๆฑ ๅ……็”ต

โ€“ ๅ†ฒๆด—้™่„‰ๆณจๅฐ„่‡‚็ณป็ปŸๅนถ่ฎฉ้ชจๅ†…ๆณจๅฐ„่…ฟๅ˜ๅนฒ๏ผˆ่ฎฉ้ชจๅ†…ๆณจๅฐ„่…ฟๅบ•

้ƒจ็š„ๅกžๅญไฟๆŒๆ‰“ๅผ€๏ผ‰

โ€“ ๆฏๆฌกๅœจไฝฟ็”จไบ†้™่„‰ๆณจๅฐ„่‡‚็š„่ฎญ็ปƒ็Žฏ่Š‚ไน‹ๅŽ๏ผŒ้ƒฝไฝฟ็”จ 60% ็š„ๅผ‚ไธ™้†‡ๆˆ– 70% ็š„ไน™้†‡ๆฅๅ†ฒๆด—้™่„‰ๆณจๅฐ„่‡‚

โ€“ ็”จไธ€ๅ—ๆนฟๅธƒๆฅๆ“ฆๆ‹ญ็šฎ่‚ค

โ€“ ๆ‹ฟๅผ€ๆนฟๅธƒๆˆ–ไบš้บปๅ“

โ€“ ็”จๆนฟๅธƒๆˆ–ๅค–็”จ้…’็ฒพๆ“ฆๆŽ‰่ƒถๅธฆๆฎ‹็•™็‰ฉ

โ€“ ๆ นๆฎๆจกๆ‹Ÿไบบ็š„ไฝฟ็”จๆƒ…ๅ†ต๏ผŒๆ›ดๆขๅทฒๆŸ่€—ๆˆ–ๆŸๅ็š„ๆจกๅ—ใ€‚

โ€“ ๆ›ดๆขๆœ‰ๅฏ่งๆŸๅ็š„็”ต็ผ†ๆˆ–่ฟžๆŽฅๅ™จ

โ€“ ๅบ”่ฏทๅˆๆ ผไบบๅฃซๅฎšๆœŸ่ฟ›่กŒไฟๅ…ป

ๅฆ‚ไธ‹ๆƒ…ๅ†ตๆ€ปๆ˜ฏ้œ€่ฆ่ฟ›่กŒ็ปดไฟฎ๏ผš

โ€“ ๅฝ“ๆถฒไฝ“ๆบขๅ‡บๅˆฐๆจกๆ‹Ÿไบบๅ†…้ƒจๆˆ–่กจ้ขๆ—ถ

โ€“ ๅœจ็ฐๅฐ˜ๆปกๅธƒ็š„็Žฏๅขƒไธญไฝฟ็”จไน‹ๅŽ

็ปดๆŠค

Page 213: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

211

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆ‰“ๅผ€่บฏๅนฒ

ๆ‰“ๅผ€ๆจกๆ‹Ÿไบบ่บฏๅนฒ๏ผŒๆ‰ง่กŒ็›ธๅ…ณ็จ‹ๅบ๏ผŒไพ‹ๅฆ‚๏ผš

โ€“ ่ฟžๆŽฅๆˆ–ๆ›ดๆขๅ››่‚ข

โ€“ ๆ›ดๆขๆจกๆ‹Ÿไบบ็”ตๆฑ 

โ€“ ๆ›ดๆข้ผ“่ƒธๆฐ”ๅ›Šๅ’Œ่‚บ้ƒจๆฐ”ๅ›Š

โ€“ ๆ›ดๆข่บฏๅนฒ็šฎ่‚ค

โ€“ ่ฟ›่กŒไธ€่ˆฌๆ€งๆฃ€ๆŸฅ

่ญฆๅ‘Š๏ผšไปŽๅทฆๅˆฐๅณๆ‰“ๅผ€่บฏๅนฒ๏ผŒ่ฝป่ฝป่งฃๅผ€็šฎ่‚คใ€‚ๅˆ‡ๅ‹ฟ็”จๅŠ›ๆ‹‰ๆ‰ฏ

ไปฅๆ‰ฏ่ตท่บฏๅนฒ็šฎ่‚ค๏ผŒ่ฟ™ๆ ทๅฏ่ƒฝไผšๆŸๅ่ƒธ้ƒจ็บฟ็ผ†ใ€‚

1. ่งฃๅผ€่บฏๅนฒๅทฆไพงๅ’ŒๅŒ่‚ฉ็š„่บฏๅนฒ็šฎ่‚คๅ›บๅฎšๅ™จใ€‚

ๆ›ดๆขๆจกๆ‹Ÿไบบ็”ตๆฑ 

1. ๆ‰“ๅผ€ๆจกๆ‹Ÿไบบ่บฏๅนฒใ€‚

2. ๅฐ†่บฏๅนฒ็šฎ่‚คๆŠ˜ๅ ่‡ณๅณไพงใ€‚

3. ๆ–ญๅผ€้™ค้ขค่ฟžๆŽฅๅ™จ็บฟ็ผ†ใ€‚

4. ๆจกๆ‹Ÿไบบๅณไพง่ƒธ้ƒจๆจกๅž‹ไธ‹็š„้™ค้ขค่ฟžๆŽฅๅ™จ็บฟ็ผ†ๅฟ…้กปๆ–ญๅผ€ใ€‚

ๆณจๆ„๏ผšๅˆ‡ๅ‹ฟๆ–ญๅผ€ๅฐ†่…น้ƒจๆณกๆฒซ่ฟžๆŽฅ่‡ณๆจกๆ‹Ÿไบบ็š„็ฎก้“ๅ’Œ ็”ต็ผ†ใ€‚

5. ๆŒ‰็›ธๅ็š„้กบๅบๆ‰ง่กŒ็ฌฌ 1 ่‡ณ 4 ๆญฅ๏ผŒๅฐ†่บฏๅนฒ็šฎ่‚คๆขๅคๅŽŸ็Šถใ€‚

2. ๅฐ†็”ตๆฑ ๆป‘ๅ‡บ็”ตๆฑ ๆž็‰‡ใ€‚

3. ไปŽๆจกๆ‹Ÿไบบๅ†…้ƒจๆ‹”่ตท็”ตๆฑ ็”ตๆบ่ฟžๆŽฅใ€‚่งฃๅผ€็”ตๆฑ ็”ตๆบ

่ฟžๆŽฅใ€‚

4. ไปŽๆจกๆ‹Ÿไบบๅ†…ๅ–ๅ‡บ็”ตๆฑ ใ€‚

5. ๆขไธŠๅทฒๅ……็”ต็š„็”ตๆฑ ๆˆ–ๅฎ‰่ฃ…ไธ€ๅ—็ปๆŒชๅบฆๆ ธๅ‡†็š„ๆ–ฐ SimJunior ็”ตๆฑ ใ€‚

6. ๅฐ†็”ตๆฑ ่ฟžๆŽฅ่‡ณๆจกๆ‹Ÿไบบใ€‚

7. ๆ›ดๆข่บฏๅนฒ็šฎ่‚คใ€‚

็ปดๆŠค

Page 214: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

212

ๆจกๆ‹Ÿไบบ็”ตๆฑ ๅ……็”ต

ๆจกๆ‹Ÿไบบ็”ตๆฑ ๅœจ่ฟ่กŒๆ—ถๅณ่‡ช่กŒๅ……็”ตใ€‚ๅฆ‚ๅฟ…่ฆ๏ผŒๆจกๆ‹Ÿไบบ็”ตๆฑ ๅฏไฝฟ็”จ

้€‰้…ๅค–้ƒจ็”ตๆบ้€‚้…ๅ™จ่ฟ›่กŒๅ……็”ตใ€‚

1. ้€š่ฟ‡ๆŽฅ็บฟ็›’ๅ…ณ้—ญๆจกๆ‹Ÿไบบ็š„็”ตๆบใ€‚

2. ไปŽๆจกๆ‹ŸไบบไธŠๅ–ไธ‹ๆจกๆ‹Ÿไบบ็”ตๆฑ ใ€‚

3. ๅฐ†ไธ€ไธช็ปๆ ธๅ‡†็š„ๅค–้ƒจ็”ตๆฑ ๅ……็”ตๅ™จ๏ผˆๅธฆๆœ‰็ฌฆๅˆๅฝ“ๅœฐ่ง„ๆ ผ็š„็”ต

ๆบ็บฟ๏ผ‰่ฟžๆŽฅ่‡ณๆจกๆ‹Ÿไบบ็”ตๆฑ ๅบ•้ƒจใ€‚ๅฐ†็”ตๆฑ ๅ……็”ตๅ™จ็š„็”ตๆบๆ’ๅคดๆ’

ๅ…ฅๅฃ่ฃ…็”ตๆบๆ’ๅบงไธŠใ€‚

4. ๅฝ“็”ตๆฑ ๅฎŒๆˆๅ……็”ตๆ—ถ๏ผŒ่ฏทๆ›ดๆขๆจกๆ‹Ÿไบบๅ†…็š„็”ตๆฑ ใ€‚

ๆ›ดๆข้ผ“่ƒธๆฐ”ๅ›Š

้ผ“่ƒธๆฐ”ๅ›ŠไฝไบŽ่ƒธๆฟ่พƒไฝŽ็š„ไธ€็ซฏ๏ผŒ่‚บ้ƒจไธ‹้ข็š„ไธญๅฟƒไฝ็ฝฎใ€‚

1. ๆ‰“ๅผ€่บฏๅนฒ็šฎ่‚ค๏ผŒ้œฒๅ‡บ่ƒธๆฟใ€‚ๅ‚่งๆ‰“ๅผ€่บฏๅนฒใ€‚

2. ๆ–ญๅผ€่ฟžๆŽฅ่‡ณ่‚บ้ƒจๆฐ”ๅ›ŠไธŠ็š„้€ๆ˜Ž็ฎก๏ผŒ็„ถๅŽๅ–ไธ‹่‚บ้ƒจๆฐ”ๅ›Šใ€‚

ๅฆ‚้œ€ๆ›ดๅคš่ฏฆ็ป†ไฟกๆฏ๏ผŒ่ฏทๅ‚่งๆ›ดๆข่‚บ้ƒจๆฐ”ๅ›Šใ€‚

3. ๆ–ญๅผ€่ฟžๆŽฅ่‡ณ้ผ“่ƒธๆฐ”ๅ›ŠไธŠ็š„้€ๆ˜Ž็ฎกใ€‚

4. ไธขๅผƒๆ—ง็š„ๆฐ”ๅ›Šใ€‚

5. ๆ’ๅ…ฅๆ–ฐ็š„ๆฐ”ๅ›Šใ€‚

6. ๅฐ†็ฎก้“้‡ๆ–ฐ่ฟžๆŽฅ่‡ณๆ–ฐๆฐ”ๅ›Šใ€‚

7. ๅ…ณ้—ญ่บฏๅนฒ๏ผŒ็„ถๅŽๆ›ดๆข่บฏๅนฒ็šฎ่‚คใ€‚

ๆ›ดๆข่‚บ้ƒจๆฐ”ๅ›Š

ๅฆ‚ๆžœๅ‡บ็Žฐๆผๆฐ”็Žฐ่ฑก๏ผŒๅˆ™ๅบ”ๆ›ดๆข่‚บ้ƒจๆฐ”ๅ›Š๏ผˆไฝไบŽ่ƒธ่…”ๅ†…๏ผ‰ใ€‚

1. ๆ‰“ๅผ€่บฏๅนฒ็šฎ่‚คใ€‚

2. ๆ–ญๅผ€่ฟžๆŽฅ่‡ณ่‚บ้ƒจๆฐ”ๅ›Šๅ„ไพงไธ‹้ข็š„้€ๆ˜Ž็ฎกใ€‚่ฏทๅ‚้˜…ๆ›ดๆข้ผ“่ƒธ

ๆฐ”ๅ›Šไธญ็š„็ฌฌ 2 ๆญฅๅ›พ็คบใ€‚

3. ๆ–ญๅผ€่ฟžๆŽฅ่‡ณ้กถ้ƒจไธญๅฟƒไฝ็ฝฎ็š„่‚บ้ƒจๆฐ”ๅ›Šๅคนใ€‚

4. ่ฝป่ฝปๅœฐๅฐ†่‚บ้ƒจๆฐ”ๅ›Š็š„้กถ้ƒจไธญๅฟƒ้ƒจๅˆ†ไปŽๅ…ถๅ‡นๆงฝไธญๆ‹‰่ตทใ€‚

5. ๆŒ‰็›ธๅ็š„็จ‹ๅบๅฎ‰่ฃ…ๆ–ฐ็š„่‚บ้ƒจๆฐ”ๅ›Šใ€‚

็ปดๆŠค

Page 215: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

213

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆ›ดๆขๆจกๆ‹Ÿไบบ็šฎ่‚ค

ๅฆ‚ๆžœๆจกๆ‹Ÿไบบ็šฎ่‚คๆ’•่ฃ‚ใ€็ฉฟๅญ”ๆˆ–ๅผ„่„๏ผŒๅˆ™ๅฏ่ƒฝ้œ€่ฆๆ›ดๆขใ€‚

่บฏๅนฒ็šฎ่‚ค๏ผš

ๅฆ‚้œ€ๆ›ดๆขๆจกๆ‹Ÿไบบ่บฏๅนฒ็šฎ่‚ค๏ผŒ่ฏทๅ‚่งๆ‰“ๅผ€่บฏๅนฒใ€‚

ๆ‰‹่‡‚็šฎ่‚ค๏ผš

ๅฆ‚้œ€ๆ›ดๆขๆจกๆ‹Ÿไบบๆ‰‹่‡‚็šฎ่‚ค๏ผš

1. ้€š่ฟ‡ๅฐ†ๆ—ง็šฎ่‚คไปŽๆ‰‹่‡‚ๅ’Œๆ‰‹ไธŠๆ‰’ไธ‹ๆˆ–*ๅ‰ชๅผ€็šฎ่‚ค๏ผŒ็งป้™คๆ—ง็š„ๆจก

ๆ‹Ÿไบบๆ‰‹่‡‚็šฎ่‚คใ€‚

่ญฆๅ‘Š๏ผš*่ฏทๅ‹ฟๅˆบ็ ดๆˆ–ๅ‰ชๅผ€ๅฟƒ่ฝด่‡‚ใ€‚

ๅฆ‚้œ€ๅฎ‰่ฃ…ๆ–ฐๆ‰‹่‡‚๏ผš

ๆ›ดๆขๅณ้™่„‰ๆณจๅฐ„่‡‚

1. ๆ‰“ๅผ€่บฏๅนฒ๏ผŒๅ‚่งๆ‰“ๅผ€่บฏๅนฒใ€‚

2. ๆ—‹ๅผ€ๅฐ†ๆ‰‹่‡‚ๅ›บๅฎšๅˆฐๆจกๆ‹Ÿไบบ่‚ฉ่†€ไธŠ็š„่žบ้’‰๏ผŒๅ–ไธ‹ๆ—งๆ‰‹่‡‚ใ€‚

3. ็กฎไฟ่‚ฉ่†€่žบไธๅทฒๅ……ๅˆ†ๆ—‹ๆพ๏ผŒไปฅไฝฟ่‡‚่ฝด่ƒฝๅคŸ่ฝปๆพๆป‘ๅ‡บใ€‚

4. ๆ นๆฎ็‰นๅฎšๆŒ‡ๅ—ไธขๅผƒๆ—งๆ‰‹่‡‚ใ€‚

1. ็กฎไฟ่‚ฉ้ƒจ่žบ้’‰่ถณๅคŸๆพ๏ผŒไปฅไปค่‡‚่ฝดๅฏไปฅ่ฝปๆพๆป‘ๅˆฐไฝใ€‚

2. ๅฐ†ๆ‰‹่‡‚่ฟžๆŽฅ่‡ณ่บฏๅนฒไธŠ็š„็›ธๅบ”่ฟžๆŽฅ็‚นใ€‚

3. ไป”็ป†ๅฐ†่‡‚่ฝดๆŽจ้€่ฟ›่‚ฉ้ƒจๆ”ฏๆžถ๏ผŒไปฅไฝฟ่‡‚่ฝดไธŽๆ”ฏๆžถๅ†…้ƒจ้ฝๅนณใ€‚

4. ็”จๅ†…ๅ…ญ่ง’ๆ‰ณๆ‰‹็ดงๅ›บ่‚ฉ่†€่žบไธใ€‚

ๆ›ดๆข้ชจๅ†…ๆณจๅฐ„ๅณ่…ฟ

ๅฆ‚้œ€ๆ‹†ๅธๅณๅฐ่…ฟ๏ผš

1. ็กฎไฟ่…ฟ้ƒจ็š„ๆ‰€ๆœ‰ๆถฒไฝ“ๅ‡ๅทฒๆŽ’ๅนฒใ€‚

2. ๆ—‹ๆพๅฐ†้ชจๅ†…ๆณจๅฐ„่…ฟๅ›บๅฎšๅˆฐๅคง่…ฟไธŠ็š„่žบ้’‰๏ผŒๅ–ไธ‹ๆ—ง็š„่…ฟ้ชจใ€‚

3. ๅฐ†้ชจๅ†…ๆณจๅฐ„ๅฐ่…ฟไปŽๅคง่…ฟๆป‘ๅ‡บใ€‚

4. ๆ นๆฎ็‰นๅฎšๆŒ‡ๅ—ไธขๅผƒๆ—ง็š„้ชจๅ†…ๆณจๅฐ„่…ฟใ€‚

ๆŒ‰็›ธๅ็š„้กบๅบๆ‰ง่กŒไปฅไธŠ็จ‹ๅบ๏ผŒๅฎ‰่ฃ…ๆ–ฐ็š„่…ฟ้ชจใ€‚

2. ไธขๅผƒๆ—ง็šฎ่‚คใ€‚

3. ็”จๆธฉๅ’Œ็š„ๆด—ๆถคๅ‰‚ๅŠ ๆฐด๏ผŒๆถฆๆป‘ๆ–ฐๆ‰‹่‡‚็šฎ่‚ค็š„ๅ†…้ขใ€‚

4. ็”จๆธฉๅ’Œ็š„็š‚ๆถฒๅŠ ๆฐดๆถฆๆป‘๏ผˆๆˆ–ๆถ‚ๆŠน๏ผ‰ๅฟƒ่ฝดใ€‚

5. ๅฐ†ๆจกๆ‹Ÿไบบ็š„ๆ‰‹้ƒจๆป‘ๅ…ฅ็šฎ่‚คไธญใ€‚

6. ่ฎฉๆ‰‹ๆŒ‡่ฆ†ไธŠ็šฎ่‚ค๏ผˆๅƒๆˆดๆ‰‹ๅฅ—ไธ€ๆ ท๏ผ‰ใ€‚

7. ๅฐ†็šฎ่‚คไธŠๆ‹‰๏ผŒไฝฟๅ…ถ่ฆ†็›–ๆ‰‹่‡‚ๅฟƒ่ฝดใ€‚

็ปดๆŠค

Page 216: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

214

็ณป็ปŸ่ฎพ็ฝฎ

้—ฎ้ข˜

โ€ข ๆ•ฐๆฎไธขๅคฑๆˆ–ๆ•ดไธช็ณป็ปŸๆ•…้šœ๏ผˆๆ•ดไฝ“็ณป็ปŸๆ•…้šœ๏ผ‰ใ€‚

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ๅฆ‚ๆžœ็ณป็ปŸๅ…ณ้—ญๆˆ–ๆ‰€ๆœ‰ๆ•ฐๆฎ้ƒฝไธขๅคฑๆˆ–ๆŸๅ๏ผ›่ฏท่”็ณปๆ‚จๅฝ“ๅœฐ็š„

ๆŒชๅบฆๆœๅŠกไธญๅฟƒใ€‚

LLEAP

โ€ข ๅ‚่ง่ฝฏไปถๅธฎๅŠฉๆ–‡ไปถ > LLEAP > ๆ•…้šœๆŽ’้™คๆŒ‡ๅ—ใ€‚๏ผˆๅฏไปŽ Laerdal Simulation Home ไธญ่ฎฟ้—ฎๅธฎๅŠฉ๏ผ‰

ๆŒชๅบฆ Patient Monitor

โ€ข ๅ‚่ง่ฝฏไปถๅธฎๅŠฉๆ–‡ไปถ > ๆŒชๅบฆ Patient Monitor > ๆ•…้šœๆŽ’้™คๆŒ‡ๅ—ใ€‚

๏ผˆๅฏไปŽ Laerdal Simulation Home ไธญ่ฎฟ้—ฎๅธฎๅŠฉ๏ผ‰

่ฏ„ไผฐๆŠฅๅ‘Šๅ’Œๅฝ•ๅƒ

โ€ข ๅ‚่ง SimView ๅธฎๅŠฉไธญ็š„ๆ•…้šœๆŽ’้™ค้ƒจๅˆ†๏ผˆๅฏ้€š่ฟ‡ SimView ๅฑๅน•

ไธ‹ๆ–น็š„้“พๆŽฅ่ฎฟ้—ฎ๏ผ‰ๆˆ–่€… Session Viewer ๅธฎๅŠฉไธญ็š„ๆ•…้šœๆŽ’้™คๆŒ‡ๅ—

้ƒจๅˆ†ใ€‚๏ผˆๅฏ้€š่ฟ‡ Laerdal Simulation Home ่ฎฟ้—ฎ๏ผ‰

ๆจกๆ‹Ÿไบบ

้—ฎ้ข˜

โ€ข ไธๅฏ้ข„ๆต‹็š„่กŒไธบใ€‚

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ๆจกๆ‹Ÿไบบๆ•…้šœๅฏ่ƒฝ็”ฑ็บฟ็ผ†ใ€็ฎก้“ๆˆ–่ฟžๆŽฅๅ™จๆพ่„ฑๅผ•่ตทใ€‚ๆ‰“ๅผ€่บฏ

ๅนฒ๏ผŒๆฃ€ๆŸฅๆ˜ฏๅฆๆœ‰ไปปไฝ•้ƒจไปถๆ–ญๅผ€ๆˆ–ๆณ„ๆผใ€‚ๅ‚่งๆจกๆ‹Ÿไบบ่ฎพๅฎšโ€”โ€”

ๆ‰“ๅผ€่บฏๅนฒ้ƒจๅˆ†ใ€‚

โ€ข ๅฆ‚ๆžœๅ‘็”Ÿๆถฒไฝ“ๆณ„ๆผ๏ผŒๅ…ณ้—ญๆจกๆ‹Ÿไบบ๏ผŒๅนถ่”็ณปๆŒชๅบฆๆŠ€ๆœฏๆœๅŠก้ƒจใ€‚

ๆฐ”้“ๆฑกๆŸ“

้—ฎ้ข˜

โ€ข ๆจกๆ‹Ÿไบบ็š„ๆฐ”้“ๅœจ็ป่ฟ‡ๅฃๅฏนๅฃไบบๅทฅๅ‘ผๅธไน‹ๅŽ๏ผŒๅฐฑไผš่ขซๆฑกๆŸ“ใ€‚

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ไฝฟ็”จๆจกๆ‹Ÿไบบๆนฟๅทพๆธ…ๆด—ๆจกๆ‹Ÿไบบ็š„ๅค–้ขใ€‚ไฝฟ็”จๆจกๆ‹Ÿไบบๆนฟๅทพๆธ…ๆด—ๅฃ

่…”ๅ†…้ƒจใ€‚ๆ›ดๆข่‚บ้ƒจๆฐ”ๅ›Š๏ผŒ่ฏทๅ‚้˜…ไธ‹ๅˆ—้ƒจๅˆ†๏ผš็ปดๆŠคโ€”โ€”ๆ›ดๆข

่‚บ้ƒจๆฐ”ๅ›Šใ€‚

่ƒธ้ƒจ่ฟๅŠจ

้—ฎ้ข˜

โ€ข ๆจกๆ‹Ÿไบบ็š„่ƒธ้ƒจไธๅ†ไธŠไธ‹่ตทไผใ€‚

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ๆฃ€ๆŸฅๆจกๆ‹Ÿไบบ็š„็”ตๆบๆ˜ฏๅฆๅทฒๆ‰“ๅผ€ใ€‚

โ€ข ๅœจ SimPad ๆˆ– LLEAP ไธญๆฃ€ๆŸฅ็กฎไฟ

โ€“ ๆฐ”้“ๅ‘ผๅธ็Ž‡ๆœช่ฎพๅฎšไธบ้›ถ

โ€“ ่ƒธ้ƒจ่ตทไผๆœช่ฎพๅฎšไธบๅ…ณ้—ญ

โ€“ ๅฟƒ็”ตๅ›พ่ฎพๅฎšไธบ็Œๆต่Š‚ๅพ‹ใ€‚

โ€“ ๆœช่ฎพๅฎšๆฐ”้“ๅนถๅ‘็—‡๏ผŒๅฆ‚ๆœ€ๅคงๅ‘ผๅธ้˜ปๅŠ›ๆˆ–ๅ–‰็—‰ๆŒ›ใ€‚

โ€“ ็กฎ่ฎค LLEAP ไธญ็š„ๆ•ดๅˆๅŽ‹็ผฉๆœบๅทฒๅฏ็”จใ€‚่ฏทๅ‚้˜…ไธ‹ๅˆ—้ƒจๅˆ†๏ผšๅ…ณ้—ญ

ๅ†…้ƒจๅŽ‹็ผฉๆœบใ€‚

โ€ข ๅฆ‚ๆžœไฝฟ็”จ็š„ๆ˜ฏๅค–้ƒจๅŽ‹็ผฉ็ฉบๆฐ”ๆบ๏ผŒๆฃ€ๆŸฅๅ…ถๆ˜ฏๅฆๆ‰“ๅผ€๏ผŒ็ฉบๆฐ”ๆ’

็ฎกๆ˜ฏๅฆ่ฟžๆŽฅๅˆฐๆจกๅž‹ใ€‚

โ€ข ๅ†…้ƒจๅŽ‹็ผฉๆœบๅฏ่ƒฝ่ฟ‡็ƒญใ€‚็ญ‰ๅพ…ๅคง็บฆ 20 ๅˆ†้’Ÿ๏ผŒๅพ…ๅ…ถๅ†ทๅดไธ‹ๆฅใ€‚

โ€ข ่ƒธ้ƒจ่ตทไผ่ขซ่ฎพ็ฝฎไธบไธคไพง๏ผˆไพ‹ๅฆ‚๏ผŒET ็ฎกๆ’ๅ…ฅๆ”ฏๆฐ”็ฎกๅคชๆทฑ๏ผ‰ใ€‚

โ€ข ้ผ“่ƒธๆฐ”ๅ›Šๆผๆฐ”ๆˆ–่ฟžๆŽฅ่‡ณ้ผ“่ƒธๆฐ”ๅ›Š็š„็ฎก้“ๆ‰ญ็ป“ๆˆ–ๅทฒๆ–ญๅผ€ใ€‚ๅฆ‚ๆžœ

้ผ“่ƒธๆฐ”ๅ›Šๆผๆฐ”๏ผŒ่ฏท่ฟ›่กŒๆ›ดๆข๏ผŒๅ‚่ง็ปดๆŠคโ€”โ€”ๆ›ดๆข้ผ“่ƒธๆฐ”ๅ›Šใ€‚

โ€ข ๆฃ€ๆŸฅ็ฉบๆฐ”ๆ’็ฎกๆ˜ฏๅฆๆผๆฐ”๏ผ›ๆฃ€ๆŸฅๆ‰€ๆœ‰่ฟžๆŽฅๆ˜ฏๅฆๅฎŒๅฅฝใ€‚ๅฆ‚ๆžœ

ๆผๆฐ”๏ผŒๆ›ดๆข็ฎก้“้ƒจๅˆ†ใ€‚

โ€ข ๆต…ๅฑ‚่ƒธ้ƒจ่ฟๅŠจๅ’Œๅ†…้ƒจๅŽ‹็ผฉๆœบๆŒ็ปญ่ฟ่กŒใ€‚ๅ†…้ƒจๅŽ‹็ผฉๆœบๅฏ่ƒฝ

็ฃจๆŸใ€‚่”็ณปๆŒชๅบฆๆŠ€ๆœฏๆœๅŠก้ƒจใ€‚

่‚บ้ƒจ

้—ฎ้ข˜

โ€ข ่‚บ้ƒจไธๆญฃๅธธ่ฟไฝœ

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ๆ‰“ๅผ€่บฏๅนฒๅ’Œ่ƒธๆฟใ€‚็กฎๅฎš่‚บ้ƒจ่ƒฝ่‡ช็”ฑๆ‰ฉๅผ ๏ผŒไธ”ไธ่ขซไปปไฝ•็”ต็ผ†ๆŸ็ผšใ€‚

โ€ข ๆฃ€ๆŸฅ็กฎไฟๅทฒ้€‚ๅฝ“่ฟžๆŽฅ่‚บ้ƒจๆฐ”ๅ›Š๏ผŒไธ”็ฎกๅญๆœชๆ‰ญๆ›ฒใ€‚

โ€ข ๆฃ€ๆŸฅ็กฎไฟ่‚บ้ƒจๆฐ”ๅ›Šๅค„ไบŽๆฐดๅนณไฝ็ฝฎ๏ผŒไธ”ๆ’ๅ…ฅๆญฃ็กฎใ€‚

ๆ•…้šœๆŽ’้™ค

Page 217: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

215

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

โ€ข ๆฃ€ๆŸฅ่‚บ้ƒจๆฐ”ๅ›Šๆ˜ฏๅฆๆœ‰่ฃ‚็บนๆˆ–่ฃ‚็ผใ€‚

โ€ข ็กฎๅฎšๆจกๆ‹Ÿไบบ็š„ๆฐ”้“ไธญๆฒกๆœ‰ๅฏ่ƒฝ้˜ปๅกžๆฐ”ๆต็š„้˜ป็ข็‰ฉใ€‚

โ€ข ๅฆ‚ๆžœๅœจ่ฐƒๆ•ด่‚บ้กบๅบ”ๆ€งๆ—ถๆ— ๅ˜ๅŒ–๏ผŒ่ฏท่”็ณปๆŒชๅบฆๆŠ€ๆœฏๆœๅŠก้ƒจใ€‚

โ€ข ๅฆ‚ๆžœ่‚บ้ƒจ้˜ปๅŠ›ๆฒกๆœ‰ๅ˜ๅŒ–๏ผŒ่ฏท่”็ณปๆŒชๅบฆๆŠ€ๆœฏๆœๅŠก้ƒจใ€‚

ๅฌ่ฏŠ่ฟ‡็จ‹ไธญ็š„ๆœบๆขฐๅ™ช้Ÿณ

ๅœจ LLEAP ไธญ๏ผŒ็‚นๅ‡ป <ๅฌ่ฏŠ้›†ไธญ>ใ€‚

่„‰ๆ๏ผˆๆกกๅŠจ่„‰ๅ’Œ่‚ฑๅŠจ่„‰่„‰ๆ๏ผ‰

้—ฎ้ข˜

โ€ข ๆ‘ธไธๅˆฐ่„‰ๆ

ๅฏ่ƒฝ็š„่งฃๅ†ณๆ–นๆกˆ

โ€ข ่„‰ๆ่ฃ…็ฝฎไธŠ็š„็šฎ่‚คๅฏ่ƒฝ่ฟ‡็ดงโ€”โ€”้‡ๆ–ฐ่ฐƒๆ•ด็šฎ่‚ค๏ผŒๅ†้‡ๅฏใ€‚

โ€ข ็กฎไฟๅฐ†ๆ”ถ็ผฉๅŽ‹่ฎพ็ฝฎไธบ่‡ณๅฐ‘ 60ใ€‚

โ€ข ็กฎไฟๅทฒๆ‰“ๅผ€ๅŽ‹็ผฉๆœบใ€‚

ๆณจๆ„๏ผšๅฆ‚ๆžœ่ก€ๅŽ‹่ฎพไธบ 60 ไปฅไธ‹๏ผŒๅˆ™ๅ‘จๅ›ด่„‰ๆๅฏ่ƒฝๆถˆๅคฑใ€‚

ๆจกๆ‹Ÿไบบๅ…ณๆœบ

้—ฎ้ข˜

โ€ข ๆจกๆ‹Ÿไบบๆ— ๅ“ๅบ”ใ€‚

่งฃๅ†ณๆ–นๆกˆ

1. ๆ–ญๅผ€ Link Box ็”ตๆบใ€‚

2. ๅ…ณ้—ญ SimPad๏ผŒๅฆ‚ๆžœๆ‚จๆญฃๅœจไฝฟ็”จ LLEAP๏ผŒๅˆ™ๅ…ณ้—ญๅฏผๅธˆไธชไบบ็”ต่„‘

็š„็”ตๆบใ€‚

3. ้‡ๅฏๆ‰€ๆœ‰่ฃ…็ฝฎใ€‚

ๅฆ‚ๆžœๆจกๆ‹Ÿไบบไป็„ถๆ— ๅ“ๅบ”๏ผŒ่ฏท่”็ณปๆ‚จ็š„ๆŒชๅบฆไปฃ่กจใ€‚

ๆ•…้šœๆŽ’้™ค

Page 218: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

216

ๆณจ้‡Š

Page 219: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

217

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

็ปดๆŠค

ๆ•…้šœๆŽ’้™ค

่ง„ๆ ผ

ๅค‡ไปถๅ’Œ้…ไปถ

ๆ€ปๅฐบๅฏธ

้•ฟ๏ผๅฎฝ๏ผˆไป…ๆจกๆ‹Ÿไบบ๏ผ‰๏ผš 120 ๅŽ˜็ฑณ x 42.5 ๅŽ˜็ฑณ

้‡้‡๏ผˆไป…ๆจกๆ‹Ÿไบบ๏ผ‰๏ผš 11.36 ๅ…ฌๆ–ค

ๆจกๆ‹Ÿไบบ็”ตๆบ

ๅค–้ƒจ็”ตๆบ๏ผš ่พ“ๅ…ฅ็”ตๅŽ‹ 9VDCใ€1.5A ๅ†…้ƒจ็”ตๆฑ ๏ผš 7.4Vใ€4.4Ahใ€้”‚็ฆปๅญ

่ฏทไป…ไฝฟ็”จ็ปๆ ธๅ‡†็š„ SimJunior ๅค–้ƒจ็”ตๆบๅ’Œ็”ตๆฑ ใ€‚

ๆฐ”ๅŽ‹ ๅ†…้ƒจๆฐ”ๆงฝ๏ผš ๆœ€ๅคง 6 psi ๅค–้ƒจ็ฉบๆฐ”่ฟžๆŽฅ๏ผš ๆœ€ๅคง 16 psi

ๆธฉๅบฆ้™ๅˆถ

ๆ“ไฝœๆธฉๅบฆ๏ผš +4ยบC ๅˆฐ 40ยบCๅญ˜ๆ”พๆธฉๅบฆ๏ผš -15ยบC ๅˆฐ 50ยบC

็Žฏๅขƒโ€”โ€”ไป…ๆจกๆ‹Ÿไบบ

็›ธๅฏนๆนฟๅบฆ๏ผš 20% - 90%๏ผˆไธๅ‡็ป“๏ผ‰

ๅˆ‡ๅ‹ฟๅœจๆฝฎๆนฟ็š„ๆˆทๅค–ๆกไปถไธ‹ไฝฟ็”จใ€‚

ๆœช่ฟ›่กŒ็›้›พ่ฏ•้ชŒใ€‚

ๅฐ„้ข‘้€šไฟก

ๆ“ไฝœ่Œƒๅ›ด๏ผš ๆœ€ๅคง 10 ็ฑณ

ๆจกๆ‹Ÿไบบ็š„ๆๆ–™ๅ›พ่กจ

ๆœ้ฅฐ๏ผš ๆฃ‰ใ€ๅฐผ้พ™

็šฎ่‚คๅ’Œๆฐ”้“๏ผš PVC ๅค–ๅฑ‚็กฌ่ดจๅก‘ๆ–™๏ผš PVCใ€ABS ๅ†…้ƒจๅก‘ๆ–™๏ผš ็ก…ๆ ‘่„‚ใ€TPUใ€PVCใ€่…ˆ ABSใ€POMใ€ๅฐผ้พ™ + GF ็Žฏๆฐงโ€”โ€”่šๆฐจ้…ฏ

้‡‘ๅฑž็ป„ไปถ๏ผš ้“ใ€้ป„้“œใ€้’ข

ๆœ€ไฝŽ็”ต่„‘้…็ฝฎ่ฆๆฑ‚

โ€ข ่‹ฑ็‰นๅฐ” i-core ไธ‰ไปฃๆˆ–ๆ›ดๆ–ฐ็‰ˆๆœฌ

โ€ข ่ถ…่ฟ‡ 3,000 PassMark - CPU Mark

โ€ข 4 GB ๅ†…ๅญ˜

โ€ข 120 GB ็กฌ็›˜็ฉบ้—ด

โ€ข 1,366 x 768 ๆˆ–ๆ›ดๅฅฝ

โ€ข ๅธฆ้บฆๅ…‹้ฃŽ็š„่€ณๆœบ

โ€ข USB ็ซฏๅฃ โ€“ 2

ๆœ€ไฝŽ่ฝฏไปถ่ฆๆฑ‚

โ€ข Windows 7 ๆˆ– Windows 8

โ€ข 100% DPI

ๆธ…ๆด—ๆถฒไฝ“

ๅฆ‚้œ€ๆธ…ๆดๆจกๆ‹Ÿไบบ๏ผŒ่ฏท้€‰็”จไปฅไธ‹ๆถฒไฝ“๏ผš

โ€“ ๆต“ๅบฆไธบ 60% ็š„ๅผ‚ไธ™้†‡้…’็ฒพ

โ€“ ๆต“ๅบฆไธบ 70% ็š„ไน™้†‡

โ€“ ๆถฒไฝ“็š‚ๅ’Œๆฐด็š„ๆธฉๅ’Œๆบถๆถฒ

้™ๆณจๆถฒไฝ“

่ฏทไป…ไฝฟ็”จ่’ธ้ฆๆˆ–ๅŽป็ฆปๅญๆฐดๆจกๆ‹Ÿ้™่„‰ๆณจๅฐ„ๆถฒไฝ“ๅ’Œ้ชจๅ†…ๆณจๅฐ„

ๆถฒไฝ“ใ€‚

่ง„ๆ ผ

Page 220: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

218

ๆณจ้‡Š

Page 221: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

219

็ปดๆŠค

่ง„ๆ ผ

ไป‹็ป

ๆจกๆ‹Ÿ่ฝฏไปถ

ๆจกๆ‹Ÿไบบ

่ฎพๅฎš

ๆ•…้šœๆŽ’้™ค

ๅค‡ไปถๅ’Œ้…ไปถ

ๅค‡ไปถๅ’Œ้…ไปถ

ๅฆ‚้œ€่Žทๅพ—ๅค‡ไปถๅ’Œ้…ไปถ็š„ๆœ€ๆ–ฐ็‰ˆๆœฌ๏ผŒ่ฏท่ฎฟ้—ฎ www.laerdal.com/cn/

ๅค‡ไปถๅ’Œ้…ไปถ

Page 222: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

220

ๆณจ้‡Š

Page 223: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

221

์œ ์ง€ ๊ด€๋ฆฌ 232

โ€“ ๊ฐ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜ ํ›„ ์œ ์ง€ ๊ด€๋ฆฌ 232 โ€“ ์ƒ๋ฐ˜์‹  ์—ด๊ธฐ 233โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ๊ต์ฒด 233 โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „ 234 โ€“ ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด 234 โ€“ ํ ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด 234 โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€ ๊ต์ฒด 235 โ€“ ์˜ค๋ฅธ์ชฝ IV ํŒ” ๊ต์ฒด 235 โ€“ ์˜ค๋ฅธ์ชฝ IO ๋‹ค๋ฆฌ ๊ต์ฒด 235

๋ฌธ์ œ ํ•ด๊ฒฐ 236

๊ฐœ์š” 222

โ€“ ๊ทœ์ œ ์ •๋ณด 222 โ€“ ์ผ๋ฐ˜์ ์ธ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ด€๋ฆฌ 223โ€“ SimJunior ๊ฐœ๊ด€๋„ 225 โ€“ SimJunior ๊ธฐ๋Šฅ 226

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ • 229

โ€“ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ค€๋น„ 229 โ€“ IO ๋‹ค๋ฆฌ ์ค€๋น„ 229โ€“ IV ์ˆ˜์•ก ํˆฌ์—ฌ 229 โ€“ IV ์ˆ˜์•ก ๋ฐฐ์ถœ 230 โ€“ IV ํŒ” ์„ธ์ฒ™ 230 โ€“ ์ œ์„ธ๋™ ์–ด๋Œ‘ํ„ฐ ํ”Œ๋ ˆ์ดํŠธ ์„ค์น˜ 230 โ€“ ํ˜ˆ์•• ์ปคํ”„ ์—ฐ๊ฒฐ 230 โ€“ LLEAP์—์„œ ํ˜ˆ์•• ์ปคํ”„ ๋ณด์ • 230 โ€“ SimPad์—์„œ ํ˜ˆ์•• ์ปคํ”„ ๋ณด์ • 230โ€“ ๋™๊ณต ๊ต์ฒด 231โ€“ ์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ ์‚ฌ์šฉ 231

์‚ฌ์–‘ 239

์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์†Œํ”„ํŠธ์›จ์–ด 228

โ€“ ๊ฐ•์‚ฌ PC 228 โ€“ ์†Œํ”„ํŠธ์›จ์–ด ๋ผ์ด์„ ์Šค 228 โ€“ Laerdal Simulation Home 228โ€“ LLEAP 228โ€“ Voice Conference Application 228โ€“ Patient Monitor 228โ€“ Session Viewer ๋ฐ SimView Server 228โ€“ ๊ธฐํƒ€ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ 228โ€“ SimDesigner 228โ€“ ๋„์›€๋ง ํŒŒ์ผ 228โ€“ ์›น ๋‹ค์šด๋กœ๋“œ 228

์˜ˆ๋น„ ๋ถ€ํ’ˆ ๋ฐ ๋ถ€์†ํ’ˆ 241

๋ชฉ์ฐจ KO

Page 224: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

222

๊ฐœ์š”

SimJuniorโ„ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์†Œ๊ฐœ

SimJunior๋Š” Laerdal์ด ๋ฏธ๊ตญ ์†Œ์•„๊ณผํ•™ํšŒ(American Academy of Pediatrics)์™€ ํ•จ๊ป˜ ์„ค๊ณ„ํ•œ ์‹ค์ œ ํฌ๊ธฐ์˜ ์‚ฌ์‹ค์ ์ธ ์†Œ์•„ ํ™˜์ž ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์ž…๋‹ˆ๋‹ค. SimJunior๋Š” ์—ฌ๋Ÿฌ ์˜๋ฃŒ ๋ถ„์•ผ์˜ ์ „๋ฌธ๊ฐ€ ๊ฐœ์ธ์ด๋‚˜ ํŒ€์„ ๊ต์œกํ•˜๊ธฐ ์œ„ํ•ด ์‚ฌ์šฉ๋ฉ๋‹ˆ๋‹ค.

SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋Š” ์™„์ „ํžˆ ์กฐ๋ฆฝ๋œ ์ƒํƒœ๋กœ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ๋ถ€ํ’ˆ์„ ๋ณ„๋„๋กœ ์กฐ๋ฆฝํ•  ํ•„์š”๊ฐ€ ์—†์Šต๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์œ„ํ•ด SimJunior๋ฅผ ์ค€๋น„ํ•˜๋Š” ๊ฒƒ๊ณผ ๊ด€๋ จํ•œ ์ž์„ธํ•œ ์‚ฌํ•ญ์€ "์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •" ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

SimJunior ๋„์›€๋ง ์‚ฌ์šฉ์„ค๋ช…์„œ(DFU)

SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์‚ฌ์šฉ์— ํ•„์š”ํ•œ ๋‹จ๊ณ„๋ณ„ ์„ค๋ช… ๋ฐ ์‚ฌ์ง„

์› ์ œ์กฐ์—…์ฒด์˜ ์‚ฌ์šฉ์„ค๋ช…์„œ

์› ์ œ์กฐ์—…์ฒด์˜ ๋ชจ๋“  ๋ณ„๋„ ์‚ฌ์šฉ์„ค๋ช…์„œ์™€ ๋ผ๋ฒจ ๋‚ด์šฉ์„ ์ค€์ˆ˜ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค. SimJunior ์‚ฌ์šฉ์„ค๋ช…์„œ๋Š” ์› ์ œ์กฐ์—…์ฒด์˜ ์‚ฌ์šฉ์„ค๋ช…์„œ๋ฅผ ๋Œ€์‹ ํ•˜๊ฑฐ๋‚˜ ๋Œ€์ฒดํ•˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.

SimJunior ๋น ๋ฅธ ์„ค์ • ๊ฐ€์ด๋“œ

SimJunior ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์‹œ์Šคํ…œ ์„ค์ •์— ๋Œ€ํ•œ ๋‹จ๊ณ„๋ณ„ ๊ฐ€์ด๋“œ

SimPad ์‚ฌ์šฉ์„ค๋ช…์„œ(DFU)

SimPad ์‚ฌ์šฉ์„ค๋ช…์„œ๋Š” Link Box์™€ SimPad๋ฅผ SimJunior์™€ ํ•จ๊ป˜ ์‚ฌ์šฉํ•˜๋Š” ๋ฐฉ๋ฒ•์— ๋Œ€ํ•ด ์„ค๋ช…ํ•ฉ๋‹ˆ๋‹ค.

LLEAP ๋„์›€๋ง ํŒŒ์ผ(Laerdal Learning Application)

LLEAP ๋„์›€๋ง ํŒŒ์ผ์€ Laerdal Simulation Home์—์„œ ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. Laerdal Simulation Home์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

๋„์›€๋ง ์ฃผ์ œ๋Š” ๋‹ค์Œ๊ณผ ๊ฐ™์Šต๋‹ˆ๋‹ค:

โ€“ LLEAP

โ€“ Session Viewer

โ€“ Voice Conference Application

โ€“ SimDesigner

โ€“ Trend Editor

๊ธฐ์ˆ ์  ๋„์›€

๊ธฐ์ˆ  ๊ด€๋ จ ๋„์›€์„ ๋ฐ›์œผ๋ ค๋ฉด ํ˜„์ง€ Laerdal ๊ธฐ์ˆ  ์„œ๋น„์Šค ์„ผํ„ฐ์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

์›น ๋‹ค์šด๋กœ๋“œ

www.laerdal.com/downloads์— ๋ฐฉ๋ฌธํ•ด ์ตœ์‹  ์‚ฌ์šฉ์„ค๋ช…์„œ์™€ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์†Œํ”„ํŠธ์›จ์–ด ์ƒˆ ๋ฒ„์ „์„ ๋‹ค์šด๋กœ๋“œํ•˜์‹ญ์‹œ์˜ค.

SimCenter ์ฝ˜ํ…์ธ 

SimCenter์—์„œ๋Š” ์ „ ์„ธ๊ณ„ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ „๋ฌธ๊ฐ€์˜ ๊ฒ€์ฆ๋œ ์ฝ˜ํ…์ธ ์— ์‰ฝ๊ฒŒ ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ์œผ๋ฏ€๋กœ ๊ทธ๋“ค์˜ ๊ฒฝํ—˜์„ ํ™œ์šฉํ•˜์—ฌ ๋ชจ๋“  ํ•™์Šต ๊ธฐํšŒ๋ฅผ ์ตœ๋Œ€ํ•œ ํ™œ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. SimJunior๋ฅผ ์œ„ํ•ด ํŠน๋ณ„ํžˆ ๊ฐœ๋ฐœ๋œ ๋‹ค์–‘ํ•œ ์‹œ๋‚˜๋ฆฌ์˜ค๋ฅผ ์ฐพ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. www.mysimcenter.com์„ ๋ฐฉ๋ฌธํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ˆ˜์—…์„ ๋ณด๋‹ค ์‰ฝ๊ฒŒ ์ ์šฉํ•  ์ˆ˜ ์žˆ๋Š” ๋ฐฉ๋ฒ•์„ ๊ฒ€์ƒ‰ํ•ด ๋ณด์‹ญ์‹œ์˜ค.

๊ทœ์ œ ์ •๋ณด

Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

โ€ข Reorient or relocate the receiving antenna.

โ€ข Increase the separation between the equipment and receiver.

โ€ข Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

โ€ข Consult the dealer or an experienced radio/TV technician for help.

์ฃผ์˜ ๊ทœ์ • ์ค€์ˆ˜์˜ ์ฑ…์ž„์„ ์ง€๊ณ  ์žˆ๋Š” ๋‹น์‚ฌ์ž๊ฐ€ ๋ช…์‹œ์ ์œผ๋กœ ์Šน์ธํ•˜์ง€ ์•Š์€ ๋ณ€๊ฒฝ์ด๋‚˜ ๊ฐœ์กฐ๋Š” ์‚ฌ์šฉ์ž๊ฐ€ ๋ณธ ์žฅ๋น„๋ฅผ ์กฐ์ž‘ํ•  ์ˆ˜ ์žˆ๋Š” ๊ถŒํ•œ์„ ๋ฌดํšจํ™”ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

Li-ion

๋ฆฌํŠฌ ์ด์˜จ ๋ฐฐํ„ฐ๋ฆฌ๋Š” ์žฌํ™œ์šฉํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

์ œํ’ˆ์€ ์ „์ž๊ธฐ ์ ํ•ฉ์„ฑ(EMC)์— ๋Œ€ํ•ด Council Directive 2004/ 108/EC์˜ ํ•„์ˆ˜ ์š”๊ตฌ ์กฐ๊ฑด์„ ์ค€์ˆ˜ํ•ฉ๋‹ˆ๋‹ค.

์ œํ’ˆ์€ RoHS(Restriction of the use of certain hazardous substances, ์œ ํ•ด๋ฌผ์งˆ ์ œํ•œ์ง€์นจ)์— ๋Œ€ํ•ด Council Directive 2011/65/EU๋ฅผ ์ค€์ˆ˜ํ•ฉ๋‹ˆ๋‹ค.

ํ˜„์ง€ ์š”๊ฑด๊ณผ ๊ทœ์ •์— ๋”ฐ๋ผ ํ๊ธฐํ•˜์‹ญ์‹œ์˜ค.

Page 225: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

223

๊ฐœ์š”

์ผ๋ฐ˜์ ์ธ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ด€๋ฆฌ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์™€ ๊ทธ ๊ตฌ์„ฑํ’ˆ์˜ ์„ฑ๋Šฅ๊ณผ ์ˆ˜๋ช…์„ ์ตœ์ƒ์œผ๋กœ ์œ ์ง€ํ•˜๋ ค๋ฉด ์•„๋ž˜ ์ง€์‹œ์‚ฌํ•ญ์„ ๋”ฐ๋ฅด์‹ญ์‹œ์˜ค.

์ผ๋ฐ˜์  ๊ด€๋ฆฌ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€๋ฅผ ๊นจ๋—ํ•œ ์ƒํƒœ๋กœ ์œ ์ง€ํ•˜๊ธฐ ์œ„ํ•ด ์‚ฌ์šฉ ์ „์—๋Š” ์†์„ ์”ป๊ณ  ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ๊นจ๋—ํ•œ ํ‘œ๋ฉด ์œ„์— ๋†“์œผ์‹ญ์‹œ์˜ค. Laerdal ๊ถŒ์žฅ ์‚ฌํ•ญ:

โ€“ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์‹œ๋‚˜๋ฆฌ์˜ค ์‹ค์Šต์ค‘ ์žฅ๊ฐ‘์„ ์ฐฉ์šฉํ•˜์‹ญ์‹œ์˜ค. ์ƒ‰๊น”์ด ์žˆ๋Š” ํ”Œ๋ผ์Šคํ‹ฑ ์žฅ๊ฐ‘์„ ์‚ฌ์šฉํ•˜๋ฉด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€๊ฐ€ ๋ณ€์ƒ‰๋  ์ˆ˜ ์žˆ์œผ๋ฏ€๋กœ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ทผ์ฒ˜์—์„œ ํŽ ํŠธ ๋งˆ์ปค, ์ž‰ํฌํŽœ, ์•„์„ธํ†ค, ์š”์˜ค๋“œ, ๋˜๋Š” ๊ธฐํƒ€ ์ฐฉ์ƒ‰ ์•ฝํ’ˆ์„ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์‹ ๋ฌธ์ด๋‚˜ ์ƒ‰์ข…์ด ์œ„์— ๋†“์ง€ ์•Š๋„๋ก ์ฃผ์˜ํ•˜์‹ญ์‹œ์˜ค. ์–ผ๋ฃฉ์ด ์˜๊ตฌ์ ์œผ๋กœ ๋‚จ์„ ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€๋Š” ์ˆœํ•œ ๋ฌผ๋น„๋ˆ„๋กœ ๋‹ฆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๊ธฐ๋„๋Š” ์ ์ ˆํžˆ ์‚ด๊ท ํ•  ์ˆ˜ ์—†์œผ๋ฏ€๋กœ ์ด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ๋Š” ๋‹ค์Œ๊ณผ ๊ฐ™์€ ์ˆ ๊ธฐ๋Š” ์‹œ๋„ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ๊ตฌ๊ฐ• ๋Œ€ ๊ตฌ๊ฐ•/๊ตฌ๊ฐ• ๋Œ€ ๋งˆ์Šคํฌ ํ™˜๊ธฐ

โ€“ ์ธ๊ณต ๊ตฌํ† ๋ฌผ ๋˜๋Š” ํก์ž…์šฉ ์•ก์ฒด์˜ ์‚ฝ์ž…

โ€“ ๊ต์œก ์„ธ์…˜์—์„œ IV ํŒ”์— ์ˆ˜์•ก์„ ํˆฌ์—ฌํ•œ ๊ฒฝ์šฐ, ๊ต์œก ์„ธ์…˜ ํ›„ ์ฆ‰์‹œ ํŒ”์—์„œ ์•ก์ฒด๋ฅผ ๋นผ๋‚ด์‹ญ์‹œ์˜ค.

โ€“ Laerdal ๊ธฐ๋„ ์œคํ™œ์ œ๋งŒ์„ ์‚ฌ์šฉํ•˜๋˜, ์ ์ •๋Ÿ‰ ๋งŒํผ๋งŒ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ตฌ์„ฑํ’ˆ ๋ชจ๋“ˆ์„ ์„ธ์ฒ™ํ•œ ํ›„ ํ—น๊ตฌ์–ด ๊ฑด์กฐ์‹œํ‚ค์‹ญ์‹œ์˜ค.

โ€“ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๋’ค๋กœ ์ ‘์€ ํ›„ ๋‚ด๋ถ€์— ํŒŒ์šฐ๋”๋ฅผ ๋ฟŒ๋ ค ๋งˆ์ฐฐ์„ ์ค„์ด์‹ญ์‹œ์˜ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ‰๋ถ€ ๊ตฌ๋ฉ์— ํŒŒ์šฐ๋”๋ฅผ ํ˜๋ฆฌ์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

ํ™˜๊ฒฝ ์ถ”์šด ํ™˜๊ฒฝ์—์„œ๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์ž‘๋™ํ•˜๊ธฐ ์ „, ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜จ๋„๊ฐ€ ์‹ค๋‚ด ์˜จ๋„์™€ ๊ฐ™์•„์งˆ ๋•Œ๊นŒ์ง€ ๊ธฐ๋‹ค๋ฆฝ๋‹ˆ๋‹ค.

๊ณผ์—ด์„ ๋ฐฉ์ง€ํ•˜๊ณ  ๋งˆ๋ชจ๋ฅผ ์ค„์ด๋Š” ๋ฐฉ๋ฒ•:

โ€“ 40ยฐC ์ด์ƒ์˜ ์˜จ๋„์—์„œ ์‚ฌ์šฉํ•  ๋•Œ์—๋Š” ํ•ญ์ƒ ๊ต์œก ์„ธ์…˜ ์‚ฌ์ด์— ๋งˆ๋„คํ‚น์˜ ์—ด์„ ์‹ํžˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์นจ๋Œ€์—์„œ ์‚ฌ์šฉ ์‹œ, ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ ๋ฐฉ์—ด์„ ๋ง‰๋Š” ๋ฌด๊ฑฐ์šด ์นจ๊ตฌ๋กœ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ๋ฎ์œผ๋ฉด ์•ˆ ๋ฉ๋‹ˆ๋‹ค.

์ผ๋ฐ˜์ ์ธ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ทจ๊ธ‰

์•„๋ž˜์˜ ์˜ˆ๋ฐฉ์ฑ…์„ ์ค€์ˆ˜ํ•ด ์‹ ์ฒด์  ์ƒํ•ด ๋˜๋Š” ์ œํ’ˆ ์†์ƒ์„ ๋ฐฉ์ง€ ํ•˜์‹ญ์‹œ์˜ค:

โ€“ ์ด ์„ค๋ช…์„œ์˜ ์ง€์‹œ ์‚ฌํ•ญ์— ๋”ฐ๋ผ์„œ๋งŒ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์•ก์ฒด๋ฅผ ์ฃผ์ž…ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ๊ธฐ๊ตฌ, ํŠœ๋ธŒ, ๋˜๋Š” ๊ธฐ๋„ ์žฅ๋น„๋ฅผ ์‚ฝ์ž…ํ•˜๊ธฐ ์ „์—๋Š” ์ œ๊ณต๋ฐ›์€ ์œคํ™œ์ œ๋ฅผ ๊ตฌ๊ฐ• ๋ฐ ๋น„๊ฐ• ๊ธฐ๋„์— ๋ฐ”๋ฆ…๋‹ˆ๋‹ค. ๋˜ํ•œ ๊ธฐ๊ตฌ ๋ฐ ํŠœ๋ธŒ๋ฅผ ์‚ฌ์šฉํ•˜๊ธฐ ์ „์—๋Š” ์œคํ™œ์ œ๋ฅผ ๋ฐ”๋ฆ…๋‹ˆ๋‹ค.

โ€“ ์ธ๊ณตํ˜ธํก ์‹œ ๊ฐ€์Šตํ™”๋œ ๊ณต๊ธฐ๋ฅผ ์ฃผ์ž…ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ๋‚ด๋ถ€ ํŠœ๋ธŒ์™€ ์ผ€์ด๋ธ”์ด ๋ถ„๋ฆฌ๋˜์–ด ์žˆ์œผ๋ฉด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์Šตํ•œ ์ƒํƒœ๋กœ ์‹ค์™ธ์—์„œ SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์‚ฌ์šฉํ•˜๋ฉด ๊ฐ์ „์ด๋‚˜ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์†์ƒ์ด ๋ฐœ์ƒํ•  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ 35ยฐC๊ฐ€ ๋„˜๋Š” ์˜จ๋„์—์„œ ์ œ์„ธ๋™๊ธฐ๋ฅผ ์‚ฌ์šฉํ•˜๋ฉด ๊ณผ์—ด๋  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.

๊ฒฝ๊ณ : ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์ž๋™ ํ‰๋ถ€ ์••๋ฐ• ๊ธฐ๊ธฐ๋ฅผ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

๋ผํ…์Šค ์ทจ๊ธ‰ ์ฃผ์˜: ์ด ์ œํ’ˆ์—๋Š” ์ฒœ์—ฐ๊ณ ๋ฌด ๋ผํ…์Šค๊ฐ€ ํฌํ•จ๋˜์–ด ์žˆ์–ด ์ธ์ฒด์— ์ ‘์ด‰ํ–ˆ์„ ๊ฒฝ์šฐ์— ์•Œ๋Ÿฌ์ง€ ๋ฐ˜์‘์„ ์ผ์œผํ‚ฌ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์ œ์„ธ๋™ ์œ„ํ—˜ SimJunior๋Š” ์ œ์„ธ๋™์„ ํ—ˆ์šฉํ•ฉ๋‹ˆ๋‹ค.

์ผ๋ฐ˜์  ์ œ์„ธ๋™๊ธฐ๋ฅผ SimJunior์— ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ œ์„ธ๋™ ์ค‘, ์ œ์„ธ๋™๊ธฐ์™€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—๋Š” ๊ฐ์ „์˜ ์œ„ํ—˜์ด ์žˆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์ œ์„ธ๋™๊ธฐ๋ฅผ ์‚ฌ์šฉํ•  ๋•Œ๋Š” ๋ชจ๋“  ํ‘œ์ค€ ์•ˆ์ „ ์ˆ˜์น™์„ ์ค€์ˆ˜ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ์ œ์„ธ๋™๊ธฐ์™€ ๊ด€๋ จ ์žฅ๋น„์™€ ํ•จ๊ป˜ ์ œ๊ณต๋œ ๋ชจ๋“  ์•ˆ์ „ ๋ฐ ์ž‘๋™๋ฒ•์„ ์ฝ๊ณ  ๋”ฐ๋ฅด์‹ญ์‹œ์˜ค.

โ€ข ์ œ์„ธ๋™ ์ค‘์—๋Š” ์™ธ๋ถ€ ํŒจ๋“ค๊ณผ ์ „๊ทน ๋ถ€์œ„ ๊ฐ„์˜ ์ ‘์ด‰์„ ๋ฐฉ์ง€ํ•จ์œผ๋กœ์จ ์ œ์„ธ๋™๊ธฐ ํ”„๋กœํ† ์ฝœ์„ ๋”ฐ๋ฅด์‹ญ์‹œ์˜ค. 300J๊นŒ์ง€ ์ œ์„ธ๋™ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€ข ์•ˆ์ „ ์กฐ์น˜๋ฅผ ๋”ฐ๋ฅด์ง€ ์•Š์œผ๋ฉด ๋ถ€์ƒ์ด๋‚˜ ์‚ฌ๋ง์„ ์ดˆ๋ž˜ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๋ณด๋‹ค ์ž์„ธํ•œ ์ •๋ณด๋Š” ์ œ์„ธ๋™๊ธฐ์˜ ์‚ฌ์šฉ์„ค๋ช…์„œ๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

๊ฒฝ๊ณ  ์‚ฌํ•ญ:

โ€“ ์ œ์„ธ๋™์„ ์ˆ˜ํ–‰ํ•  ๋•Œ์—๋Š” ์ œ์„ธ๋™๊ธฐ ์ปค๋„ฅํ„ฐ ๋˜๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ํ‰๋ถ€์— ์žฅ์ฐฉ๋˜์–ด ์žˆ๋Š” ์žฝ ํ”Œ๋ ˆ์ดํŠธ๋ฅผ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค. ECG ๋ชจ๋‹ˆํ„ฐ๋ง ์šฉ๋„๋กœ๋งŒ ์„ค๊ณ„๋œ ECG ์ปค๋„ฅํ„ฐ์—๋Š” ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ECG ์ปค๋„ฅํ„ฐ์—์„œ ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜๋ฉด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ๋‚ด๋ถ€ ์ „์ž ๋ถ€ํ’ˆ์ด ์†์ƒ๋˜๊ณ  ๋ถ€์ƒ์ด ๋ฐœ์ƒํ•  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ „์›์ด ๊บผ์ ธ ์žˆ๊ฑฐ๋‚˜ ์ •์ƒ ์ž‘๋™ํ•˜์ง€ ์•Š์„ ๋•Œ ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

์ฑ…์ž„์˜ ์ œํ•œ

์˜๋ฃŒ์ง„ ํ›ˆ๋ จ์„ ์œ„ํ•œ SimJunior ํ™˜์ž ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์‹œ์Šคํ…œ์˜ ์‚ฌ์šฉ์€ ์ ํ•ฉํ•œ ์‚ฌ์šฉ์ž ๊ต์œก์„ ๋ฐ›๊ณ , ๊ต์œก์  ์›์น™์€ ๋ฌผ๋ก  ์ ์ •ํ•œ ์˜๋ฃŒ ํ”„๋กœํ† ์ฝœ์— ๋Œ€ํ•ด ์ดํ•ด๋ฅผ ํ•˜๊ณ  ์žˆ๋Š” ๊ธฐ์ˆ ์ž ๋˜๋Š” ์˜๋ฃŒ์ธ์ด ๋‹ด๋‹นํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค. ๋‹ค๋ฅธ ๋ชจ๋“  ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋‚˜ ์œ ์‚ฌํ•œ ๊ต์œก์šฉ ๊ธฐ๊ธฐ์™€ ๋งˆ์ฐฌ๊ฐ€์ง€๋กœ ํ•ด๋ถ€ํ•™์  ๊ธฐ๋Šฅ ๋ฐ ์ƒ๋ฆฌ์  ๋ชจ๋ธ๋ง์—๋Š” ๊ทผ์‚ฌ์น˜, ๋ณ€๋™ ๋ฐ ๋ถ€์ •ํ™•ํ•œ ์‚ฌํ•ญ์ด ์žˆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๋”ฐ๋ผ์„œ Laerdal์—์„œ๋Š” ๋ชจ๋“  ํŠน์„ฑ์ด ์ „์ ์œผ๋กœ ์ •ํ™•ํ•˜๋‹ค๋Š” ๋ณด์žฅ์„ ํ•˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.

์ œํ•œ๋ณด์ฆ

Laerdal ์ œํ•œ๋ณด์ฆ ์ฑ…์ž๋ฅผ ์‚ดํŽด๋ณด์‹œ๊ฑฐ๋‚˜ www.laerdal.com/kr/์„ ์ฐธ์กฐํ•˜์‹œ๊ธฐ ๋ฐ”๋ž๋‹ˆ๋‹ค.

์ œ์กฐ ๊ตญ๊ฐ€ - SimJunior๋Š” ๋ฏธ๊ตญ์—์„œ ์ œ์กฐํ•ฉ๋‹ˆ๋‹ค.

Laerdal Medical P.O. Box 38 226 FM 116 Gatesville, Texas 76528, USA

Page 226: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

224

๊ฐœ์š”

์ œ์„ธ๋™์‹œ ๊ณผ์—ด๋˜์ง€ ์•Š๋„๋ก 45์ดˆ ๊ฐ„ ์ œ์„ธ๋™์„ 3ํšŒ ๋„˜๊ฒŒ ์—ฐ์†์ ์œผ๋กœ ์‹ค์‹œํ•˜์ง€ ๋ง๊ณ  ๊ทธ ํ›„์—๋Š” 1๋ถ„ ๊ฐ„ CPR์„ ์‹ค์‹œํ•ฉ๋‹ˆ๋‹ค. ์ „๊ธฐ ์ถฉ๊ฒฉ์„ ์ฃผ๋Š” ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜์„ 30๋ถ„ ์ด์ƒ ์ง€์†ํ•˜์ง€ ๋งˆ์‹œ๊ณ , 30๋ถ„ ํ›„์—๋Š” ๋‹ค์Œ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์ƒˆ๋กœ ์‹œ์ž‘ํ•˜๊ธฐ ์ „์— 15๋ถ„ ์ด์ƒ ์ „๊ธฐ์ถฉ๊ฒฉ ์‹œํ–‰์„ ๋ชจ๋‘ ๋ฉˆ์ถ”์‹ญ์‹œ์˜ค. ์ด ๊ณผ์ •์„ 4์‹œ๊ฐ„ ์ด์ƒ ๋ฐ˜๋ณตํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ๋˜ํ•œ ๋ถ„๋‹น 2 x 300J ์ด์ƒ์˜ ์ œ์„ธ๋™๊ธฐ ๋ฐฉ์ „์„ ์‹ค์‹œํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

๊ฒฝ๊ณ  ์‚ฌํ•ญ:

โ€“ ์ œ์„ธ๋™ ๋„์ค‘ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋Š” ์ „๋„์„ฑ ํ‘œ๋ฉด ๋˜๋Š” ๋ฌผ์ฒด์— ์ ‘์ด‰ํ•˜์ง€ ์•Š๋„๋ก ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ๋ชจ๋“  ์ธํ™”์„ฑ ํ™˜๊ฒฝ์—์„œ๋Š” ์‚ฌ์šฉ์„ ํ”ผํ•˜์‹ญ์‹œ์˜ค. ์˜ˆ๋ฅผ ๋“ค์–ด, ๊ณ ๋†๋„ ์‚ฐ์†Œ์˜ ์‚ฌ์šฉ์€ ์ œ์„ธ๋™ ์ค‘ ํ”ผํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ทผ์ฒ˜์—์„œ ๊ณ ๋†๋„ ์‚ฐ์†Œ๋ฅผ ์‚ฌ์šฉํ•  ๊ฒฝ์šฐ ํ™˜๊ธฐ๋ฅผ ์ž˜ ์‹œํ‚ค์‹ญ์‹œ์˜ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒ๋ฐ˜์‹ ์€ ํ•ญ์ƒ ๊ฑด์กฐํ•œ ์ƒํƒœ๋ฅผ ์œ ์ง€ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜๊ธฐ ์ „์— ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๊ฐ€ ์˜จ๋„์— ์ ์‘ํ•˜๋„๋ก ๋‘์‹ญ์‹œ์˜ค. ์˜จ๋„์˜ ๊ธ‰๊ฒฉํ•œ ๋ณ€ํ™”๋Š” ์ „๊ธฐ ๋ถ€ํ’ˆ์— ์‘๊ฒฐ์„ ์œ ๋ฐœํ•˜์—ฌ ๊ฐ์ „์˜ ์œ„ํ—˜์ด ๋”ฐ๋ฅผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€์— ์ „๊ทน์œผ๋กœ ์ธํ•œ ์ž๊ตญ์ด ๋‚จ์ง€ ์•Š๋„๋ก ํ™˜์ž์šฉ ์ „๋„์„ฑ ์ ค์ด๋‚˜ ์ „๋„์„ฑ ์ œ์„ธ๋™ ํŒจ๋“œ๋ฅผ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์ œ์„ธ๋™ ์ค‘ ์ œ์„ธ๋™ ์ปค๋„ฅํ„ฐ๋ฅผ ๋„ˆ๋ฌด ์„ธ๊ฒŒ ๋ˆŒ๋Ÿฌ๋„ ์•„ํฌ์™€ ์ ์‹์„ ์œ ๋ฐœํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๊ฐ€ ์žฅ์ฐฉ๋˜์–ด ์žˆ์ง€ ์•Š์€ ๊ฒฝ์šฐ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

๊ธฐ๊ณ„์  ๋˜๋Š” ์ „๊ธฐ์  ์œ„ํ—˜

๋‹ค์Œ์˜ ๊ฒฝ์šฐ SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์ƒ๋ฐ˜์‹ ์— ์‚ฌ์ง€๊ฐ€ ๋ถ€์ฐฉ๋˜์–ด ์žˆ์ง€ ์•Š์€ ๊ฒฝ์šฐ

โ€“ ํ”ผ๋ถ€๊ฐ€ ์ฐข์–ด์กŒ๊ฑฐ๋‚˜ ์˜ฌ๋ฐ”๋ฅด๊ฒŒ ๊ณ ์ •๋˜์ง€ ์•Š์€ ๊ฒฝ์šฐ

โ€“ ๋‚ด๋ถ€ ๋˜๋Š” ์™ธ๋ถ€ ์ผ€์ด๋ธ”, ํŠœ๋ธŒ ๋˜๋Š” ์ปค๋„ฅํ„ฐ๊ฐ€ ์†์ƒ๋œ ๊ฒฝ์šฐ

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋‚ด๋ถ€ ๋˜๋Š” ํ‘œ๋ฉด์— ์•ก์ฒด ๋ˆ„์ˆ˜๊ฐ€ ์žˆ๋Š” ๊ฒฝ์šฐ

โ€“ ๊ณต๊ธฐ ์œ ์ถœ ๋˜๋Š” ๊ธฐ๊ณ„์  ์†์ƒ์„ ๋‚˜ํƒ€๋‚ด๋Š” ๋น„์ •์ƒ์ ์ธ ์†Œ์Œ์ด ๋“ค๋ฆด ๊ฒฝ์šฐ

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๊ฐ€ ์‘๋‹ตํ•˜์ง€ ์•Š๊ฑฐ๋‚˜, ๋น„์ •์ƒ์ ์ธ ๋ƒ„์ƒˆ๋‚˜ ์—ฐ๊ธฐ๊ฐ€ ๋‚˜๋Š” ๋“ฑ ์ „๊ธฐ์  ์˜ค์ž‘๋™ ์ง•ํ›„๊ฐ€ ์žˆ๋Š” ๊ฒฝ์šฐ

๊ฒฝ๊ณ :

โ€“ ๊ณ ์žฅ์˜ ์œ„ํ—˜์„ ๋ฐฉ์ง€ํ•˜์‹ญ์‹œ์˜ค. ์™ธ๋ถ€ ํ”ผ๋ถ€ ์—†์ด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

๋ฐฐํ„ฐ๋ฆฌ ์‚ฌ์šฉ ๋ฐ ์œ ์ง€

โ€“ SimJunior, Link Box ๋ฐ SimPad์— ์ „์›์„ ๊ณต๊ธ‰ํ•˜๋ ค๋ฉด ์Šน์ธ ๋ฐ›์€ ๋ฐฐํ„ฐ๋ฆฌ๋งŒ์„ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

โ€“ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์˜ฌ๋ฐ”๋ฅด๊ฒŒ ์„ค์น˜ํ•˜์‹ญ์‹œ์˜ค. ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์˜ฌ๋ฐ”๋ฅด์ง€ ์•Š๊ฒŒ ์„ค์น˜ํ•˜๋ฉด ํšŒ๋กœ๊ฐ€ ํ•ฉ์„ ๋  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๊ฒฝ๊ณ  ์‚ฌํ•ญ:

โ€“ ๋ฐฐํ„ฐ๋ฆฌ๋Š” ํ˜„์ง€ ๊ทœ์ •์— ๋”ฐ๋ผ ํ๊ธฐํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์™ธ๋ถ€ ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „๊ธฐ๋Š” ์‹ค๋‚ด์—์„œ๋งŒ ์‚ฌ์šฉํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ๋Š” 0ยฐC~40ยฐC ์‚ฌ์ด์˜ ์˜จ๋„์—์„œ๋งŒ ์ถฉ์ „ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์˜ค์šฉ, ๋ถ„ํ•ดํ•˜๊ฑฐ๋‚˜ ์ˆ˜๋ฆฌํ•˜๋ ค๊ณ  ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ๋ฐฐํ„ฐ๋ฆฌ๊ฐ€ ์™ธ๊ด€์ƒ ์†์ƒ์„ ์ž…์—ˆ๊ฑฐ๋‚˜, ์˜ค์ž‘๋™ ํ•˜๊ฑฐ๋‚˜, ๋ˆ„์•ก์ด ๋˜๋Š” ๊ฒƒ์œผ๋กœ ๋ณด์ด๋ฉด ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์ „๊ธฐ ๋ถ€ํ’ˆ, ๊ณ ์—ด, ๋˜๋Š” ์—ฐ๊ธฐ๊ฐ€ ๋ฐœ์ƒํ•˜๋Š” ๋ถ€ํ’ˆ๊ณผ ์ง์ ‘์  ์ ‘์ด‰์„ ๋ฐฉ์ง€ํ•˜๋„๋ก ๊ฐ๋ณ„ํžˆ ์ฃผ์˜ํ•˜์‹ญ์‹œ์˜ค. ๋ฐฐํ„ฐ๋ฆฌ ๋ˆ„์•ก์˜ ๊ฒฝ์šฐ, ์•ˆ์ „ํ•˜๋‹ค๊ณ  ํŒ๋‹จ์ด ๋œ ๋•Œ์— ๋ฐฐํ„ฐ๋ฆฌ ์—ฐ๊ฒฐ์„ ์ฐจ๋‹จํ•œ ํ›„ ๊บผ๋‚ด์‹ญ์‹œ์˜ค.

โ€“ ์•ก์ฒด์— ๋…ธ์ถœ์‹œํ‚ค๋ฉด ํญ๋ฐœ์˜ ์œ„ํ—˜์ด ๋”ฐ๋ฆ…๋‹ˆ๋‹ค.

โ€“ ๋งค 30ํšŒ ์ถฉ์ „ ์ฃผ๊ธฐ๋งˆ๋‹ค ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์™„์ „ํžˆ ๋ฐฉ์ „์‹œํ‚จ ๋‹ค์Œ ์ถฉ์ „ํ•˜์‹ญ์‹œ์˜ค. ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ๋ฐฉ์ „์‹œํ‚ค๋ ค๋ฉด ์ž๋™์œผ๋กœ ๊บผ์งˆ ๋•Œ๊นŒ์ง€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ๋ฐฐํ„ฐ๋ฆฌ ์ „์›์œผ๋กœ ์ž‘๋™ํ•˜์‹ญ์‹œ์˜ค.

โ€“ Laerdal SimJunior ๋ฐฐํ„ฐ๋ฆฌ๋กœ๋งŒ ๊ต์ฒดํ•˜์‹ญ์‹œ์˜ค.

๋ณด๊ด€ ๋ฐ ์šด์†ก

โ€“ ์™„์ถฉ๋œ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ 1๊ฐœ์›” ์ด์ƒ ๋ณด๊ด€ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ๋Š” ํ•ญ๊ณต ์šด์†ก ์‹œ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋‚ด์— ์žฅ์ฐฉ๋œ ์ƒํƒœ๋กœ ์šด๋ฐ˜ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์—ฌ๋ถ„์˜ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์šด๋ฐ˜ํ•  ๋•Œ์—๋Š” ์ตœ์‹  ์šด์†ก ๊ทœ์ •์„ ์œ„ํ•ด ํ•ญ๊ณต์‚ฌ ๋˜๋Š” ๋ฐฐ์†ก์—…์ฒด์—๊ฒŒ ์—ฐ๋ฝํ•˜์‹ญ์‹œ์˜ค.

๊ฒฝ๊ณ :

โ€“ SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐ ๋ถ€์†ํ’ˆ์€ ์šด๋ฐ˜์šฉ ์ผ€์ด์Šค์— ํ•จ๊ป˜ ๋‹ด์„ ๊ฒฝ์šฐ ๋ฌด๊ฒ์Šต๋‹ˆ๋‹ค. ์šด์†ก ๋ฐ ๋ณด๊ด€ ์ค‘์—๋Š” ์‹ ์ฒด์  ์ƒํ•ด ๋˜๋Š” ์ œํ’ˆ ์†์ƒ์„ ๋ฐฉ์ง€ํ•˜๊ธฐ ์œ„ํ•ด SimJunior๋ฅผ ํ•ญ์ƒ ๋‹จ๋‹จํžˆ ๊ณ ์ •์‹œํ‚ค์‹ญ์‹œ์˜ค.

Page 227: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

225

IO ๋‹ค๋ฆฌ

IO ๋‹ค๋ฆฌ ํฌํŠธ

SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ

ECG(์šฐ์ธก ํŒ”) ์ปค๋„ฅํ„ฐ

Sternum ์ œ์„ธ๋™ ํŒ

์ •๋งฅ๋กœ ํ™•๋ณด์šฉ ํŒ”

ECG(์šฐ์ธก ๋‹ค๋ฆฌ) ์ปค๋„ฅํ„ฐ

์ „์› ์ผ€์ด๋ธ”

์™ธ๋ถ€ ๊ณต๊ธฐ ์—ฐ๊ฒฐ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ผ€์ด๋ธ”(60ํ•€)

๊ฐœ์š”

ECG(์ขŒ์ธก ํŒ”) ์ปค๋„ฅํ„ฐ

ํ˜ˆ์•• ์ธก์ •์šฉ ํŒ”

Apex ์ œ์„ธ๋™ ํŒ

ECG(์ขŒ์ธก ๋‹ค๋ฆฌ) ์ปค๋„ฅํ„ฐ

Page 228: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

226

๊ฐœ์š”

SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ SimJunior๋Š” ์ธ๋ช…๊ตฌ์กฐ ์ˆ ๊ธฐ์˜ ์ธํ„ฐ๋ž™ํ‹ฐ๋ธŒํ•œ ๊ต์œก ํ›ˆ๋ จ์„ ์šฉ์ดํ•˜๊ฒŒ ํ•˜๊ณ  ์ž„์ƒ์  ๊ฐœ์ž…, ๊ฐ•์‚ฌ์˜ ์ œ์–ด, ํ™˜์ž ์ง„๋‹จ ๋ฐ ์น˜๋ฃŒ์— ๋Œ€ํ•œ ํšจ๊ณผ์  ์—ฐ์Šต์„ ์œ„ํ•œ ์‚ฌ์ „ ํ”„๋กœ๊ทธ๋žจ๋œ ์‹œ๋‚˜๋ฆฌ์˜ค์— ๋ฐ˜์‘ํ•ฉ๋‹ˆ๋‹ค.

์ž์—ฐ์Šค๋Ÿฌ์šด ํ˜ธํก, ๊ธฐ๋„ ์กฐ์ ˆ, ์Œ์„ฑ, ์‚ฌ์šด๋“œ, ECG ๋ฐ ๊ธฐํƒ€ ์ž„์ƒ์  ๊ธฐ๋Šฅ์„ ํฌํ•จํ•ด SimJunior๋Š” ์™„๋ฒฝํ•œ ๊ธฐ๋Šฅ์„ ์ˆ˜ํ–‰ํ•˜๋Š” ์†Œ์•„์šฉ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์ž…๋‹ˆ๋‹ค. SimJunior๋Š” ๋Œ€๋ถ€๋ถ„์˜ ํ™œ๋ ฅ ์ง•ํ›„์˜ ๊ด€์ฐฐ ๋ฐ ์ธ์‹์„ ๊ฐ€๋Šฅํ•˜๊ฒŒ ํ•˜์—ฌ ๊ฐ•์‚ฌ๊ฐ€ ์‚ฌ์‹ค์ ์ธ ์ž„์ƒ ์ƒํ™ฉ์— ๊ธฐ๋ฐ˜ํ•ด ํ•™์ƒ๋“ค์˜ ๊ธฐ๋Ÿ‰์„ ํ‰๊ฐ€ํ•  ์ˆ˜ ์žˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

SimJunior ๊ธฐ๋Šฅ

โ€“ ์–ด๋ ค์šด ๊ธฐ๋„ ๊ด€๋ฆฌ, ๊ตฌ๊ฐ• ๋ฐ ๋น„๊ฐ• ํŠœ๋ธŒ ์‚ฝ๊ด€์˜ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์œ„ํ•œ ์‚ฌ์‹ค์ ์ธ ๊ธฐ๋„

โ€“ ๊ด€์ฐฐ ๊ฐ€๋Šฅํ•œ ํ˜ธํก

โ€“ ์ œ์„ธ๋™ ๋ฐ ์‹ฌ์กฐ์œจ ์ „ํ™˜์„ ํฌํ•จํ•˜๋Š” ์‹ฌ์žฅ ๊ธฐ๋Šฅ

โ€“ ๊ต์ฒด ๊ฐ€๋Šฅํ•œ ๋™๊ณต(์ •์ƒ, ์‚ฐ๋Œ€, ์ถ•๋™ ํ˜•ํƒœ)๊ณผ ํ•จ๊ป˜ ์ œ๊ณต๋˜๋Š” ๋ˆˆ

โ€“ ๋ฐœ์ž‘์„ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ํ•˜๊ธฐ ์œ„ํ•œ ๋ฐœ์ž‘

โ€“ ๊ฐ€์Šด ์••๋ฐ•

โ€“ ์ •๋งฅ๋กœ ํ™•๋ณด

โ€“ ์ •์ƒ ๋ฐ ๋น„์ •์ƒ์ ์ธ ์‹ฌ์Œ, ํ˜ธํก์Œ ๋ฐ ์žฅ์Œ

โ€“ ์‚ฌ์ „ ํ”„๋กœ๊ทธ๋ž˜๋ฐ๊ณผ ์ž…์ฆ๋œ ํ™˜์ž ์‹œ๋‚˜๋ฆฌ์˜ค๋ฅผ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•œ ์ž๋™ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ œ์–ด

SimPad ๋˜๋Š” LLEAP(PC)์˜ ์‹œ๋‚˜๋ฆฌ์˜ค๋ฅผ ์ด์šฉํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์ž์ฒด์ ์œผ๋กœ ์‹คํ–‰ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ํ™˜์ž ์ฆ์ƒ์˜ ๋ฐœํ˜„์€ ์‚ฌ์ „์— ํ”„๋กœ๊ทธ๋ž˜๋ฐ๋˜์–ด ์žˆ์œผ๋ฉฐ ๊ต์œก์ƒ์˜ ๊ฐœ์ž…์— ๋”ฐ๋ผ ์ž๋™์œผ๋กœ ๋ฐ˜์‘ํ•ฉ๋‹ˆ๋‹ค.

์ „์ฒด ์น˜์ˆ˜

๊ธธ์ด/ํญ(์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ํ•œํ•จ): 120cm x 42.5cm ๋ฌด๊ฒŒ(์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ํ•œํ•จ): 11.36kg

SimJunior ์˜๋ณต

SimJunior๋Š” ํƒˆ๋ถ€์ฐฉ์ด ์šฉ์ดํ•œ ๋ฒจํฌ๋กœ๊ฐ€ ๋ถ€์ฐฉ๋˜์–ด ์žˆ๋Š” ๋งž์ถค ๋””์ž์ธ ์˜๋ณต์ด ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์„ธํƒ์— ๋Œ€ํ•œ ์•ˆ๋‚ด ์‚ฌํ•ญ์€ ์˜๋ณต์˜ ๋ผ๋ฒจ์— ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ์…”์ธ 

โ€“ ๋ฐ˜๋ฐ”์ง€

โ€“ ์‚ฌ๊ฐ ํŒฌํ‹ฐ

์ผ๋ฐ˜ ์ž„์ƒ์  ๊ธฐ๋Šฅ

๊ธฐ๋„ ํŠน์„ฑ

๊ธฐ๋„๋Š” ํ•ด๋ถ€ํ•™์ ์œผ๋กœ ์‹ค์ œ์™€ ์œ ์‚ฌํ•œ ๊ธฐ๊ด€์œผ๋กœ ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค. ๋‹ค์Œ๊ณผ ๊ฐ™์€ ์ˆ ๊ธฐ๋ฅผ ์ ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค:

โ€“ ๋จธ๋ฆฌ ๊ธฐ์šธ์ž„ / ํ„ฑ ๋“ค์–ด์˜ฌ๋ฆฌ๊ธฐ

โ€“ ํ„ฑ ๋“ค์–ด์˜ฌ๋ฆฌ๊ธฐ(์—ฐ์ ‘์‹ ํ„ฑ ํฌํ•จ)

โ€“ ์œค์ƒ ์••๋ฐ• ๋ฐ ์กฐ์ž‘

โ€“ ํก์ž…(๊ตฌ๊ฐ• ๋ฐ ๋น„๊ฐ•)

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋Š” ์ผ๋ฐ˜์ ์ธ ์ฒ˜์น˜์™€ ์‘๊ธ‰ ์ƒํ™ฉ์‹œ ๋‹ค์Œ๊ณผ ๊ฐ™์€ ๋ฐฉ๋ฒ•์˜ ํ™˜๊ธฐ ์ˆ ๊ธฐ๋ฅผ ์‹ค์‹œํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ ๋ฐฑ-๋งˆ์Šคํฌ ์ธ๊ณตํ˜ธํก

โ€“ ๊ตฌ๊ธฐ๊ด€ ์‚ฝ๊ด€

โ€“ ๋น„๊ธฐ๊ด€ ์‚ฝ๊ด€

๊ธฐ๋„ ์žฅ๋น„๋Š” ์‚ฌ์šฉ ์ „ Laerdal ๊ธฐ๋„ ์œคํ™œ์ œ๋ฅผ ๋ฐ”๋ฅด์‹ญ์‹œ์˜ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ๊ธฐ๋„๋ฅผ ํ™•๋ณดํ•˜๊ธฐ ์œ„ํ•ด ์ ํ•ฉํ•ฉ ์žฅ๋น„ ๋˜๋Š” ๋ฐฉ๋ฒ•์€ ๋‹ค์Œ๊ณผ ๊ฐ™์Šต๋‹ˆ๋‹ค.

โ€“ ํ›„๋‘ ๋งˆ์Šคํฌ(LMA) (์‚ฌ์ด์ฆˆ #2.5)

โ€“ ๊ธฐ๊ด€ ๋‚ด ํŠœ๋ธŒ ์‚ฝ๊ด€(์‚ฌ์ด์ฆˆ ID 4.5 ์ปคํ”„ํ˜•, 5.5 ๋น„-์ปคํ”„ํ˜•)

ํŠœ๋ธŒ ์‚ฝ์ž…์‹œ์—๋Š” ํƒ์นจ์„ ์‚ฌ์šฉํ•˜๋Š” ๊ฒƒ์ด ์ข‹์Šต๋‹ˆ๋‹ค. ํƒ์นจ์€ ET ํŠœ๋ธŒ ๋์„ ๋„˜์–ด์„œ ์‚ฝ์ž…ํ•˜์ง€ ์•Š๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

๋‹ค์Œ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒํƒœ๋Š” ํŠœ๋ธŒ ์žฅ์ฐฉ์ด ์˜ฌ๋ฐ”๋ฅด์ง€ ์•Š์Œ์„ ๋‚˜ํƒ€๋ƒ…๋‹ˆ๋‹ค.

โ€“ ์šฐ์ธก ๊ธฐ๊ด€์ง€ ์‚ฝ๊ด€ - ํŽธ์ธก ํ‰๋ถ€ ์ƒ์Šน

โ€“ ์œ„ ํŒฝ๋งŒ

โ€“ ํ‰๋ถ€์Œ ์†Œ์‹ค(ํ˜ธํก ๋‹จ์› ์ฐธ์กฐ)

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ธฐ๋Šฅ์€ ๋‹ค์–‘ํ•œ ๊ธฐ๋„ ์‹œ๋‚˜๋ฆฌ์˜ค๋ฅผ ํ‘œํ˜„ํ•˜๊ธฐ ์œ„ํ•œ ์„ค์ •์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

โ€“ ํ˜€ ๋ถ€์ข… - ์ •์ƒ, ์ค‘๊ฐ„ ๋ฐ ์ตœ๋Œ€ ์ˆ˜์ค€

โ€“ ํ ๊ฐœ๋ฐฉ ๋˜๋Š” ํ์‡„

ํ˜ธํก ๊ธฐ๋Šฅ

SimJunior๋Š” ๊ฐ€์‹œ์ ์ธ ํ‰๋ถ€ ์ƒ์Šน๊ณผ ํ•˜๊ฐ• ๋ฐ ๋‹ค์–‘ํ•œ ํ˜ธํก์ˆ˜์™€ ํ•จ๊ป˜ ์ž์—ฐ์Šค๋Ÿฌ์šด ํ˜ธํก ์‹œ๋ฎฌ๋ ˆ์ด์…˜์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. ํ˜ธํก์€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋ฅธ์ชฝ ํ—ˆ๋ฒ…์ง€ ๋‚ด๋ถ€์— ์žฅ์ฐฉ๋˜์–ด ์žˆ๋Š” ์ปดํ”„๋ ˆ์„œ์—์„œ ์ƒ์„ฑํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์ž์—ฐ์Šค๋Ÿฌ์šด ํ˜ธํก์„ ๋‚˜ํƒ€๋‚ด๋Š” ์–‘์ชฝ ํ‰๋ถ€ ์ƒ์Šน ๋ฐ ํ•˜๊ฐ•

โ€“ ํ™˜๊ธฐ ์ค‘ ์šฐ์ธก ๊ธฐ๊ด€์ง€(mainstem) ์‚ฝ๊ด€๊ณผ ํ•จ๊ป˜ ํ‰๋ถ€ ํ•œ์ชฝ๋งŒ ์ƒ์Šน ๋ฐ ํ•˜๊ฐ•

โ€“ ํ•œ์ชฝ ๋ฐ ์–‘์ชฝ ํ์Œ

โ€“ ์ •์ƒ ๋ฐ ๋น„์ •์ƒ์  ํ˜ธํก์Œ

โ€“ ๋‹ค์–‘ํ•œ ํ˜ธํก์ˆ˜(๋ถ„๋‹น 0~60ํšŒ)

โ€“ ์ „๋ฉด๋ถ€ ์ฒญ์ง„ ๋ถ€์œ„(4)

์ขŒ์ธก ํ์™€ ์šฐ์ธก ํ๋Š” ๋”ฐ๋กœ ๋˜๋Š” ํ•จ๊ป˜ ํ์‡„์‹œ์ผœ ๋ถ€๋ถ„์  ๋˜๋Š” ์ „์ฒด์ ์ธ ๊ธฐ๋„ ํ์‡„๋ฅผ ๊ตฌํ˜„ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋Š” ๋ณด์กฐ ํ™˜๊ธฐ๋„ ํ•จ๊ป˜ ์ ์šฉํ•  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.

์ฐธ๊ณ : ํ๋Š” PEEP ๋ฐธ๋ธŒ์™€ ํ•จ๊ป˜ ์‚ฌ์šฉํ•˜๋„๋ก ์ œ์ž‘๋˜์ง€ ์•Š์•˜์Šต๋‹ˆ๋‹ค.

Page 229: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

227

๊ฐœ์š”

์ˆœํ™˜ ๊ด€๋ จ ๊ธฐ๋Šฅ

์‹ฌ์žฅ:

โ€“ ๋‹ค์–‘ํ•œ ECG library, ๋งฅ๋ฐ• ๋ฒ”์œ„ 0~200

โ€“ ์‹ฌ์Œ - ์ „๋ฉด๋ถ€ ์œ„์น˜(1)

โ€“ ECG ๋ฆฌ๋“ฌ ๋ชจ๋‹ˆํ„ฐ๋ง(4-์ปค๋„ฅํ„ฐ, 3-lead ECG)

โ€“ 12-lead ECG ๋””์Šคํ”Œ๋ ˆ์ด(LLEAP ์‚ฌ์šฉ์— ํ•œํ•จ)

โ€“ ์ธ๊ณต์‹ฌ์žฅ๋ฐ•๋™์กฐ์œจ(pacing)

โ€“ ์‹ค์ œ ์ œ์„ธ๋™๊ธฐ๋ฅผ ์‚ฌ์šฉํ•œ ์ œ์„ธ๋™ ๋ฐ ์‹ฌ์กฐ์œจ์ „ํ™˜

์ œ์„ธ๋™:

โ€“ ์ œ์„ธ๋™์‹œ ์‹ฌ์ „๋„ ๋ฆฌ๋“ฌ ์ž๋™ ์ „ํ™˜์— ํ•„์š”ํ•œ ์ „๊ธฐ ์ถฉ๊ฒฉ ํšŸ์ˆ˜๋Š” ๊ฐ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ํ™˜์ž ์‚ฌ๋ก€ ๋ณ„๋กœ ์„ค์ •๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.

์ œ์„ธ๋™ ์Šคํ„ฐ๋“œ:

3-lead ECG ์Šคํ„ฐ๋“œ:

ํ˜ˆ์•• ๋ฐ ๋งฅ๋ฐ•:

โ€“ ์ฝ”๋กœํŠธ์ฝ”ํ”„ ์Œ์„ ์ฒญ์ง„ํ•˜์—ฌ ํ˜ˆ์•• ์ˆ˜๋™ ์ธก์ •

โ€“ ์–‘์ชฝ ๊ฒฝ๋™๋งฅ

โ€“ ์ค‘์‹ฌ ๋งฅ๋ฐ•์€ ์ •์ƒ(Normal), ์•ฝํ•จ(Weak), ์†Œ์‹ค(Absent)๋กœ ์„ค์ •์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์š”๊ณจ/์ƒ์™„ ๋งฅ๋ฐ•์€ ์ •์ƒ(Normal), ์•ฝํ•จ(Weak), ์†Œ์‹ค(Absent) ๋กœ ์„ค์ •์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

โ€“ ECG์™€ ์ผ์น˜๋œ ๊ฒฝ๋™๋งฅ, ์ƒ์™„, ์š”๊ณจ ๋งฅ๋ฐ•

โ€“ BP์— ๋”ฐ๋ผ ๋ณ€๊ฒฝ ๊ฐ€๋Šฅํ•œ ๋งฅ๋ฐ• ๊ฐ•๋„

โ€“ ๋งฅ๋ฐ• ์ด‰์ง„์ด ๊ฐ์ง€๋˜์–ด ๊ธฐ๋ก๋ฉ๋‹ˆ๋‹ค.

CPR ๊ธฐ๋Šฅ

โ€“ 2010 ๊ฐ€์ด๋“œ๋ผ์ธ์„ ์ค€์ˆ˜ํ•จ

โ€“ ์••๋ฐ•์œผ๋กœ ์ด‰์ง€ ๊ฐ€๋Šฅํ•œ ๋งฅ๋ฐ•, ํ˜ˆ์•• ํŒŒํ˜• ๋ฐ ECG ๊ฐ„์„ญ๊ตฌํ˜„(artifact)์ด ์ƒ์„ฑ๋จ

โ€“ ์‹ค์ œ์™€ ๊ฐ™์€ ์••๋ฐ• ๊นŠ์ด์™€ ์ €ํ•ญ

โ€“ ์••๋ฐ• ๊นŠ์ด ๋ฐ ์••๋ฐ• ์†๋„์˜ ๊ฐ์ง€

ํ˜ˆ์•ก ์ฃผ์ž… ๊ธฐ๋Šฅ

IV ํ™•๋ณด:

IV ํ™•๋ณด๋Š” ์˜ค๋ฅธํŒ” ๋ฐ ์˜ค๋ฅธ์†์—์„œ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. IV ํŒ”์€ IV ์‚ฝ์ž…, ์ธํ“จ์ „ ๋ฐ bolus ํˆฌ์—ฌ์— ๋Œ€ํ•ด ์„ค์ •์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค:

โ€“ ์ „๋ฐ•์˜ ๋ง์ดˆ ํ˜ˆ๊ด€

โ€“ ํŒ” ์˜ค๊ธˆ ๋ฐ ์†๋“ฑ

๊ณจ๋‚ด(IO) ์ฃผ์‚ฌ:

๊ณจ๋‚ด(IO) ์ฃผ์‚ฌ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค:

โ€“ ๊ฒฝ๊ณจ ์กฐ๋ฉด(์˜ค๋ฅธ์ชฝ)

โ€“ ๊ฒฝ๊ณจ ๋‚ด์ธก

์ฐธ๊ณ : SimJunior์—๋Š” ๊ทผ์œก(IM) ์ฃผ์‚ฌ ๋ถ€์œ„๊ฐ€ ์—†์Šต๋‹ˆ๋‹ค. IM ์ฃผ์‚ฌ๋ฅผ ์‹œ๋„ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

SimJunior์— ๋Œ€ํ•œ ์‚ฌ์šด๋“œ ์„ค์ •

SimJunior๋Š” ์‹ฌ์Œ, ํ์Œ, ์žฅ์Œ์˜ ์ฒญ์ง„ ๋ฐ ์ธ์ง€ํ•˜๋Š” ๋ฐ ํ•„์š”ํ•œ ์—ฌ๋Ÿฌ ๋ถ€์œ„๋ฅผ ์ง€์›ํ•ฉ๋‹ˆ๋‹ค. SimJunior๋Š” ์Œ์„ฑ ์„ค์ •๋„ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

SimJunior ์‚ฌ์šด๋“œ ์„ค์ •์— ๊ด€ํ•œ ์ž์„ธํ•œ ๋‚ด์šฉ์€ SimPad ์‚ฌ์šฉ์„ค๋ช…์„œ ๋˜๋Š” LLEAP ๋„์›€๋ง ํŒŒ์ผ์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

Page 230: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

228

๊ฐ•์‚ฌ PC

๊ฐ•์‚ฌ PC๋Š” LLEAP ์†Œํ”„ํŠธ์›จ์–ด๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜์„ ๊ด€๋ฆฌํ•ฉ๋‹ˆ๋‹ค. Laerdal Simulation Home์—์„œ LLEAP๊ณผ ๊ธฐํƒ€ ์œ ์šฉํ•œ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ๊ด€๋ จ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์— ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์†Œํ”„ํŠธ์›จ์–ด ๋ผ์ด์„ ์Šค

๊ฐ•์‚ฌ PC๋Š” Laerdal Medical์—์„œ ์‚ฌ์ „ ํ™œ์„ฑํ™”๋œ LLEAP ๋ผ์ด์„ ์Šค๊ฐ€ ์„ค์น˜๋œ ์ƒํƒœ๋กœ ๋ฐฐ์†ก๋ฉ๋‹ˆ๋‹ค.

์ปดํ“จํ„ฐ ํ•˜๋“œ์›จ์–ด๋ฅผ ๊ต์ฒดํ•˜๊ฑฐ๋‚˜ ๊ฐฑ์‹ ํ•˜๋ฉด(์˜ˆ: ์ƒˆ ํ•˜๋“œ ๋“œ๋ผ์ด๋ธŒ๋‚˜ ๋งˆ๋”๋ณด๋“œ) ๋ผ์ด์„ ์Šค๊ฐ€ ์‚ญ์ œ๋  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค. ๋ผ์ด์„ ์Šค ์žฌํ™œ์„ฑํ™” ์ž‘์—…์— ๋„์›€์ด ํ•„์š”ํ•˜๋‹ค๋ฉด ํ˜„์ง€ Laerdal ์ง€์›ํŒ€์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

Laerdal Simulation HomeLaerdal Simulation Home์€ LLEAP ๋ฐ ํ™˜์ž ์‹œ๋ฎฌ๋ ˆ์ด์…˜๊ณผ ๊ด€๋ จ๋œ ๊ธฐํƒ€ Laerdal ํ”„๋กœ๊ทธ๋žจ์„ ์ฐพ๊ณ  ์‹œ์ž‘ํ•  ์ˆ˜ ์žˆ๋Š” ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์ž…๋‹ˆ๋‹ค. ๋„์›€๋ง ํŒŒ์ผ๋„ ์—ฌ๊ธฐ์—์„œ ์—ด ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. Laerdal Simulation Home์€ Windows ์‹œ์ž‘ ๋ฉ”๋‰ด(Windows 7) ์•„๋ž˜ Laerdal Medical ํด๋”์— ์žˆ์Šต๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜์—์„œ ์‚ฌ์šฉ๋˜๋Š” ์†Œํ”„ํŠธ์›จ์–ด๋Š” ๋‹ค์Œ์˜ ์ฃผ์š” ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์œผ๋กœ ๋ถ„๋ฅ˜ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

โ€“ LLEAP(Laerdal Learning Application)

โ€“ Voice Conference Application

โ€“ Patient Monitor

โ€“ SimView Server ๋˜๋Š” Session Viewer

์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์„ค๊ณ„ ๋˜๋Š” ์ค€๋น„ํ•˜๋Š” ๊ณผ์ •์—์„œ SimDesigner ๋ฐ ๊ธฐํƒ€ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ๋„ ์‚ฌ์šฉ๋ฉ๋‹ˆ๋‹ค.

LLEAPLLEAP(Laerdal Learning Application)์€ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜์„ ์‹คํ–‰, ์ œ์–ด ๋ฐ ๋ชจ๋‹ˆํ„ฐํ•˜๋Š” ๊ฐ•์‚ฌ์šฉ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์ž…๋‹ˆ๋‹ค. LLEAP์€ ์ž๋™ ๋˜๋Š” ์ˆ˜๋™ ๋ชจ๋“œ๋กœ ์ž‘๋™ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ž๋™ ๋ชจ๋“œ๋Š” ์‚ฌ์ „ ํ”„๋กœ๊ทธ๋ž˜๋ฐ๋œ ์‹œ๋‚˜๋ฆฌ์˜ค์— ์‚ฌ์šฉ๋˜๋ฉฐ, ์ˆ˜๋™ ๋ชจ๋“œ๋Š” ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜ ์ „๋ฐ˜์— ๊ฑธ์ณ ๊ฐ•์‚ฌ๊ฐ€ ์ง์ ‘ ์ œ์–ดํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ˆ˜๋™ ๋ชจ๋“œ์—์„œ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์‹คํ–‰ํ•˜๋ ค๋ฉด ์ž„์ƒ์ ์ธ ์Œํ–ฅ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์ƒ์„ฑํ•˜๋Š” ๋ฐ ํ•„์š”ํ•œ ์˜๋ฃŒ ์ „๋ฌธ ์ง€์‹์ด ์š”๊ตฌ๋ฉ๋‹ˆ๋‹ค.

Voice Conference Application(VCA)์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ค‘์— ์‚ฌ์šฉ๋˜๋Š” ๋ชจ๋“  ์Œ์„ฑ์„ ์ „์†กํ•˜๋ ค๋ฉด VCA ์†Œํ”„ํŠธ์›จ์–ด๊ฐ€ ํ•„์š”ํ•ฉ๋‹ˆ๋‹ค. ๊ฐ•์‚ฌ๋Š” ์„ธ์…˜ ์ค‘ VCA ์†Œํ”„ํŠธ์›จ์–ด๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ํ†ตํ•ด ์˜์‚ฌ์†Œํ†ต์„ ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๋˜ํ•œ ๋„คํŠธ์›Œํฌ์˜ ๋‹ค๋ฅธ ๊ฐ•์‚ฌ๋“ค๊ณผ ์˜๊ฒฌ์„ ๋‚˜๋ˆ„๊ณ  ํšŒ์›๋“ค๋งŒ ์˜์‚ฌ์†Œํ†ตํ•  ์ˆ˜ ์žˆ๋Š” ๋ณ„๋„์˜ ์ฑ„๋„์„ ๋งŒ๋“ค ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

Patient MonitorPatient Monitor ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์€ ์ผ๋ฐ˜์ ์ธ ๋ณ‘์›์˜ ํ™˜์ž ๋ชจ๋‹ˆํ„ฐ์™€ ์œ ์‚ฌํ•ฉ๋‹ˆ๋‹ค. ํ•™์Šต์ž์šฉ ์ œ์–ด ์žฅ์น˜๋กœ์„œ, ๊ฐ•์‚ฌ์™€ ํ•™์Šต์ž๊ฐ€ ํ™”๋ฉด์˜ ํ„ฐ์น˜ ๋ฉ”๋‰ด๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์„ค์ • ๋ฐ ์ œ์–ดํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

Session Viewer ๋ฐ SimView ServerSession Viewer ๋ฐ SimView Server๋Š” ์‹œ๋ฎฌ๋ ˆ์ด์…˜ํ•˜๋Š” ๋™์•ˆ ๋™์˜์ƒ ๋ฐ ํ™˜์ž ๋ชจ๋‹ˆํ„ฐ ํ™”๋ฉด์˜ ์บก์ฒ˜๋ฅผ ๊ธฐ๋กํ•˜๊ณ , ์„ธ์…˜์„ ๋””๋ธŒ๋ฆฌํ•‘ํ•˜๋Š” ์ธํ„ฐํŽ˜์ด์Šค๋ฅผ ์ œ๊ณตํ•˜๋Š” ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์ž…๋‹ˆ๋‹ค. ์„ธ์…˜ ์ข…๋ฃŒ ํ›„ ๋””๋ธŒ๋ฆฌํ•‘์„ ์œ„ํ•ด Session Viewer ๋ฐ SimView Server์— LLEAP์— ์ƒ์„ฑ๋œ ๋กœ๊ทธ ํŒŒ์ผ์ด ๋™์˜์ƒ ํŒŒ์ผ๊ณผ ํ•จ๊ป˜ ์ „์†ก ๋ฐ ๋ณ‘ํ•ฉ๋ฉ๋‹ˆ๋‹ค.

SimView Server๋Š” ์ผ๋ฐ˜์ ์œผ๋กœ LLEAP์— ์‚ฌ์šฉ๋˜๋Š” ๊ฐ™์€ ์ปดํ“จํ„ฐ์—์„œ ๋กœ์ปฌ๋กœ ์‹คํ–‰๋˜๊ณ , SimView Server๋Š” ๋กœ์ปฌ ๋„คํŠธ์›Œํฌ์˜ ์ „์šฉ ์„œ๋ฒ„์—์„œ ์‹คํ–‰๋ฉ๋‹ˆ๋‹ค. LLEAP์„ ์ฒ˜์Œ ์‹คํ–‰ํ•˜๋ฉด ์ปดํ“จํ„ฐ ๋˜๋Š” ๋กœ์ปฌ ๋„คํŠธ์›Œํฌ์—์„œ ์‚ฌ์šฉ ๊ฐ€๋Šฅํ•œ ๋””๋ธŒ๋ฆฌํ•‘ ์‹œ์Šคํ…œ์„ ์„ ํƒํ•˜๋ผ๋Š” ๋ฉ”์‹œ์ง€๊ฐ€ ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค. ์„ ํƒ ํ•ญ๋ชฉ์€ ๋‚˜์ค‘์— ๋ณ€๊ฒฝํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๊ธฐํƒ€ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ

์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜๊ณผ ํ•จ๊ป˜ ์‚ฌ์šฉํ•˜๋Š” ๋‹ค๋ฅธ ํ”„๋กœ๊ทธ๋žจ๋“ค๋„ ์žˆ์Šต๋‹ˆ๋‹ค. ์˜ˆ๋ฅผ ๋“ค์–ด License Manager๋Š” ํ”„๋กœ๊ทธ๋žจ ๋ผ์ด์„ ์Šค๋ฅผ ์ฒ˜๋ฆฌํ•˜๋ฉฐ Simulator Firmware & Network Fixer๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ํŽŒ์›จ์–ด๋ฅผ ์—…๋ฐ์ดํŠธํ•˜๊ฑฐ๋‚˜ ๋„คํŠธ์›Œํฌ ๋ฌธ์ œ๋ฅผ ํ•ด๊ฒฐํ•ฉ๋‹ˆ๋‹ค.

SimDesignerSimDesigner๋Š” ์‚ฌ์šฉ์ž๊ฐ€ ์‚ฌ์ „ ํ”„๋กœ๊ทธ๋ž˜๋ฐ ์‹œ๋‚˜๋ฆฌ์˜ค๋ฅผ ๊ตฌ์„ฑํ•  ์ˆ˜ ์žˆ๋Š” ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์ž…๋‹ˆ๋‹ค. ์‹œ๋‚˜๋ฆฌ์˜ค์˜ ๊ทธ๋ž˜ํ”ฝ ํ‘œํ˜„์„ ๋ถ„์„ํ•˜๊ณ  ์ธ์‡„ํ•˜๋Š” ์ž‘์—…์—๋„ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๋ ˆ๊ฑฐ์‹œ ๊ฐ•์‚ฌ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ ํŒŒ์ผ์„ LLEAP ํ˜ธํ™˜ ํŒŒ์ผ ํ˜•์‹์œผ๋กœ ๋ณ€ํ™˜ํ•  ์ˆ˜ ์žˆ๋„๋ก SimDesigner๋ฅผ ์„ค์น˜ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

๋„์›€๋ง ํŒŒ์ผ

LLEAP ์†Œํ”„ํŠธ์›จ์–ด ๋ฐ ๊ธฐํƒ€ ์‘์šฉ ํ”„๋กœ๊ทธ๋žจ์— ๋Œ€ํ•œ ๋ณด๋‹ค ์ž์„ธํ•œ ์ •๋ณด๋Š” ๋„์›€๋ง ํŒŒ์ผ์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

1. Windows์˜ <์‹œ์ž‘>, <๋ชจ๋“  ํ”„๋กœ๊ทธ๋žจ>์„ ํด๋ฆญํ•ฉ๋‹ˆ๋‹ค.

2. <Laerdal Simulation Home>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

3. <๋„์›€๋ง>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

์›น ๋‹ค์šด๋กœ๋“œ

www.laerdal.com/kr/downloads์— ๋ฐฉ๋ฌธํ•ด ์ตœ์‹  ์‚ฌ์šฉ์„ค๋ช…์„œ์™€ ์†Œํ”„ํŠธ์›จ์–ด๋ฅผ ๋‹ค์šด๋กœ๋“œํ•˜์‹ญ์‹œ์˜ค.

์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์†Œํ”„ํŠธ์›จ์–ด

Page 231: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

229

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ค€๋น„

SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๊ฐ€ ์ค€๋น„๊ฐ€ ์™„๋ฃŒ๋˜๊ณ  ํ•ด๋‹นํ•˜๋Š” ๋ชจ๋“  ์ธํ„ฐ๋ž™ํ‹ฐ๋ธŒ ์žฅ์น˜(SimPad ๋˜๋Š” ๊ฐ•์‚ฌ PC ๋ฐ ํ™˜์ž ๋ชจ๋‹ˆํ„ฐ)๊ฐ€ ์„ค์น˜ ์™„๋ฃŒ๋˜์–ด ์‚ฌ์šฉ ์ค€๋น„๊ฐ€ ์™„๋ฃŒ๋œ ํ›„ SimJunior๊ฐ€ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ๊ตฌ๋™ํ•˜๊ธฐ ์ „ ์ตœ์ข… ์ค€๋น„๋ฅผ ์ˆ˜ํ–‰ํ•  ํ•„์š”๊ฐ€ ์žˆ์Šต๋‹ˆ๋‹ค.

์ตœ์ข… ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์ค€๋น„์—๋Š” ๋‹ค์Œ ์ˆ˜ํ–‰ ๋‚ด์—ญ์ด ํฌํ•จ๋ฉ๋‹ˆ๋‹ค:

โ€ข IO ๋‹ค๋ฆฌ ์ค€๋น„

โ€ข IV ์ˆ˜์•ก ํˆฌ์—ฌ

โ€ข ๊ณผ๋„ํ•œ IV ์ˆ˜์•ก ๋ฐฐ์ถœ

โ€ข IV ํŒ” ์„ธ์ฒ™

โ€ข ์ œ์„ธ๋™๊ธฐ ์–ด๋Œ‘ํ„ฐ ํ”Œ๋ ˆ์ดํŠธ ์—ฐ๊ฒฐ

โ€ข ํ˜ˆ์•• ์ปคํ”„ ์—ฐ๊ฒฐ

โ€ข ๋™๊ณต ๊ต์ฒด

โ€ข ์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ ์—ฐ๊ฒฐ

โ€ข ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ์— ๋Œ€ํ•œ ์„ค์ • ๋ณ€๊ฒฝ

IO ๋‹ค๋ฆฌ ์ค€๋น„

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋ฅธ์ชฝ ๋‹ค๋ฆฌ๋Š” ๊ณจ๋‚ด ์ฃผ์ž… ๊ธฐ์ˆ ์„ ์—ฐ์Šตํ•˜๊ธฐ ์œ„ํ•ด ์„ค๊ณ„๋˜์—ˆ์Šต๋‹ˆ๋‹ค. ์˜ค๋ฅธ์ชฝ ๋‹ค๋ฆฌ์˜ ํ•ด๋ถ€ํ•™์  ๊ตฌ์กฐ๋Š” ๋ฌด๋ฆŽ, ๊ฒฝ๊ณจ (์ •๊ฐ•์ด๋ผˆ), ๊ฒฝ๊ณจ ์กฐ๋ฉด ๋ฐ ๊ฒฝ๊ณจ ๋‚ด์ธก ๋ถ€๋ถ„์œผ๋กœ ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค. ์˜ค๋ฅธ์ชฝ ๋‹ค๋ฆฌ๋Š” IV ํŠœ๋ธŒ ๋ฐ ์ฃผ์ž… ์ค‘ ์ €์žฅ์†Œ๋กœ ์‚ฌ์šฉํ•˜๋Š” ํ•œ ๊ฐœ์˜ IV ๋ฐฑ๊ณผ ํ•จ๊ป˜ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค.

ํ•„์š”ํ•œ ์ถ”๊ฐ€ ์žฅ๋น„:

โ€ข IV ๋ฐฑ ๋ฐ ํˆฌ์—ฌ ์„ธํŠธ

โ€ข ์ธ์กฐ ํ˜ˆ์•ก ๋†์ถ•๋ฌผ

โ€ข 35cc ์ฃผ์‚ฌ ๋ฐ 16-G ๊ณจ๋‚ด ์ฃผ์‚ฌ๋ฐ”๋Š˜

IO ๋‹ค๋ฆฌ๋ฅผ ์ฑ„์šด ํ›„ ์‚ฌ์šฉํ•˜๊ธฐ ์œ„ํ•œ ์ค€๋น„ ๋ฐฉ๋ฒ•:

1. ๋‹ค๋ฆฌ๋ฅผ ๋“ค์–ด ์˜ฌ๋ ค ์ˆ˜์ง์œผ๋กœ ์„ธ์›๋‹ˆ๋‹ค.

2. ๋ฐœ๋’ค๊ฟˆ์น˜์— ์žˆ๋Š” ํ”Œ๋Ÿฌ๊ทธ๋ฅผ ์—ฝ๋‹ˆ๋‹ค.

3. ์ฃผ์‚ฌ๊ธฐ๋ฅผ ์‚ฌ์šฉํ•ด ๋ผˆ์— ์•ฝ 240cc ๋‚ด์ง€ 250cc์˜ ์ธ์กฐ ํ˜ˆ์•ก์„ ์ฑ„์›๋‹ˆ๋‹ค.

4. IV ์ €์žฅ์šฉ ๋ฐฑ์— ์—ฐ๊ฒฐ๋œ ํŠœ๋ธŒ๋ฅผ ๋ถ€์ฐฉํ•ฉ๋‹ˆ๋‹ค. (๋กค๋Ÿฌ ํด๋žจํ”„๋ฅผ ์‚ฌ์šฉํ•ด ์••๋ ฅ ์ƒ์Šน์„ ์™„ํ™”ํ•˜๊ธฐ ์œ„ํ•ด ํ•„์š”์— ๋”ฐ๋ผ ๋ผ์ธ์„ ์—ด๊ฑฐ๋‚˜ ๋‹ซ์Šต๋‹ˆ๋‹ค.)

5. ์ €์žฅ์šฉ ๋ฐฑ์— ๋“ค์–ด๊ฐ€๋Š” ํŠœ๋ธŒ๋ฅผ ๋‹ซ์•„ ์ธ์กฐ ํ˜ˆ์•ก์ด ํก์ž…์„ ์œ„ํ•ด ๋ผˆ ์†์— ๋‚จ์•„์žˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

6. ์ €์žฅ์šฉ ๋ฐฑ์ด ๊ฐ€๋“ ์ฐจ๋ฉด, ์ฃผ์ž…์„ ์ค‘๋‹จํ•˜๊ณ  ์ด๋ฅผ ๋นˆ ๋ฐฑ๊ณผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์‚ฌ์šฉ ํ›„, ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ณด๊ด€:

โ€“ ๋ฐœ์—์„œ IV ๋ผ์ธ๊ณผ ์ €์žฅ์šฉ ๋ฐฑ์„ ๋–ผ์–ด๋ƒ…๋‹ˆ๋‹ค.

โ€“ ๋ชจ๋“  ์•ก์ฒด๊ฐ€ ํ˜๋Ÿฌ ๋‚˜์˜ค๊ฒŒ ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ํ”Œ๋Ÿฌ๊ทธ๋ฅผ ๋–ผ์–ด๋‚ธ ๋‹ค๋ฆฌ๋ฅผ ๊ฑด์กฐ์‹œํ‚ค๊ณ  ๋ณด๊ด€ํ•ฉ๋‹ˆ๋‹ค.

์ฐธ๊ณ : ์‹์—ผ์ˆ˜๋ฅผ ํˆฌ์—ฌํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ์ด๋Š” ๋‹ค๋ฆฌ๋ฅผ ๋ถ€์‹์‹œํ‚ฌ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๋ฏธ๋„ค๋ž„ ์ถ•์  ๋ฐฉ์ง€๋ฅผ ์œ„ํ•ด ์ฆ๋ฅ˜์ˆ˜ ๋˜๋Š” ํƒˆ์—ผ์ˆ˜๋ฅผ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

IV ์ˆ˜์•ก ํˆฌ์—ฌ

์˜ค๋ฅธ์ชฝ IV ํŒ”์€ ํŒ”๋š, ํŒ” ์˜ค๊ธˆ ๋ฐ ์†๋“ฑ์˜ ๋ง์ดˆ ์ •๋งฅ์— ๋Œ€ํ•œ IV ์•ฝ๋ฌผ ํˆฌ์—ฌ, IV ์‚ฝ์ž…, ์ฃผ์ž… ๋ฐ bolus ํˆฌ์—ฌ์— ๋Œ€ํ•œ ์‹ค์Šต์„ ์ง€์›ํ•ฉ๋‹ˆ๋‹ค.

IV ์‹œ๋ฎฌ๋ ˆ์ด์…˜์—์„œ๋Š” 20~22G ๋ฐ”๋Š˜์„ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค. IV ์‹œ์Šคํ…œ์ด ๋ง‰ํžˆ์ง€ ์•Š๋„๋ก ํ•˜๊ธฐ ์œ„ํ•ด์„œ๋Š” ์‹œ๋ฎฌ๋ ˆ์ด์…˜์‹œ IV ์•ฝ๋ฌผ๋กœ ์ฆ๋ฅ˜์ˆ˜ ๋˜๋Š” ํƒˆ์—ผ์ˆ˜๋งŒ์„ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •

Page 232: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

230

IV ์ˆ˜์•ก ๋ฐฐ์ถœ

IV ์ˆ˜์•ก ์‹œ์Šคํ…œ์€ ๊ฐœ๋ฐฉํ˜• ์‹œ์Šคํ…œ์ž…๋‹ˆ๋‹ค. IV ์ˆ˜์•ก์€ ํˆฌ์—ฌ๋˜๋ฉด์„œ ๋ฐฐ์ถœ๋ฉ๋‹ˆ๋‹ค.

๊ฐ ์„ธ์…˜ ์ „:

1. (์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋ฅธํŒ”์— ์žˆ๋Š”) IV ์˜ค๋ฒ„ํ”Œ๋กœ์šฐ ํŠœ๋ธŒ๋ฅผ ์˜ค๋ฒ„ํ”Œ๋กœ์šฐ ์šฉ๊ธฐ(IV ๋ฐฑ ๋“ฑ)์— ๋ถ€์ฐฉํ•ฉ๋‹ˆ๋‹ค.

2. ์‹œ๋ฎฌ๋ ˆ์ด์…˜์ด ์ง„ํ–‰๋˜๋Š” ๋™์•ˆ ์šฉ๊ธฐ์— ํˆฌ์—ฌ๋œ ์ˆ˜์•ก์ด ๋ฐฐ์ถœ๋˜๋„๋ก ํ•˜์‹ญ์‹œ์˜ค.

IV ํŒ” ์„ธ์ฒ™

๊ฐ ์„ธ์…˜ ํ›„ ๋˜๋Š” ์‚ฌ์šฉ ๋‹น์ผ ํ›„ IV ํŒ”์„ 60% ์ด์†Œํ”„๋กœํŒ์˜ฌ ๋˜๋Š” 70% ์—ํƒ„์˜ฌ๋กœ ์„ธ์ฒ™ํ•ฉ๋‹ˆ๋‹ค.

์ œ์„ธ๋™ ์–ด๋Œ‘ํ„ฐ ํ”Œ๋ ˆ์ดํŠธ ์„ค์น˜

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒ๋ฐ˜์‹ ์—๋Š” ์ œ์„ธ๋™ ์ผ€์ด๋ธ”์šฉ ์Šคํ„ฐ๋“œ ์ปค๋„ฅํ„ฐ๊ฐ€ ๋‘ ๊ฐœ ์žฅ์ฐฉ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค. ์ œ์„ธ๋™์„ ์‹œ๋„ํ•˜๊ธฐ ์ „, ๋ฐ˜๋“œ์‹œ ์ œ์„ธ๋™๊ธฐ ์Šคํ„ฐ๋“œ๋ฅผ ์ œ๊ฑฐํ•˜๊ณ  ๋ณผํŠธ๋ฅผ ํ’€์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

2๊ฐœ์˜ ์ œ์„ธ๋™ ์–ด๋Œ‘ํ„ฐ ํ”Œ๋ ˆ์ดํŠธ๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์™€ ํ•จ๊ป˜ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์ œ์„ธ๋™๊ธฐ ์–ด๋Œ‘ํ„ฐ ํŒ์€ ์‹ค์ œ ์ œ์„ธ๋™๊ธฐ๋ฅผ ์ œ์„ธ๋™ ํŒจ๋“ค๊ณผ ํ•จ๊ป˜ ์‚ฌ์šฉํ•˜๊ธฐ ์ „ ๋ฐ˜๋“œ์‹œ ์ œ์ž๋ฆฌ์— ์žฅ์ฐฉ๋˜์–ด ์žˆ์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค. ์–ด๋Œ‘ํ„ฐ ํŒ์„ ์ œ์ž๋ฆฌ์— ๋‹จ๋‹จํžˆ ๊ณ ์ •์‹œํ‚ต๋‹ˆ๋‹ค.

์ œ์„ธ๋™ ์‹œํ–‰์ค‘

์ผ๋ฐ˜์  ์ œ์„ธ๋™๊ธฐ(๋ถˆํฌํ•จ ์‚ฌํ•ญ)๋ฅผ SimJunior์— ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ „๋ฅ˜๋ฅผ ํ†ตํ•œ ์ œ์„ธ๋™์‹œ์—๋Š” ์ œ์„ธ๋™๊ธฐ์™€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ๊ฐ์ „ ์œ„ํ—˜์ด ์žˆ์„ ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์ œ์„ธ๋™๊ธฐ๋ฅผ ์‚ฌ์šฉํ•  ๋•Œ๋Š” ๋ชจ๋“  ํ‘œ์ค€ ์•ˆ์ „ ์ˆ˜์น™์„ ์ค€์ˆ˜ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

์ฃผ์˜: ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜๋Š” ๋™์•ˆ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๊ฐ€ ์ „๋„์„ฑ ํ‘œ๋ฉด์ด๋‚˜ ๋ฌผ์ฒด์— ๋‹ฟ์•„ ์žˆ์–ด์„œ๋Š” ์•ˆ ๋ฉ๋‹ˆ๋‹ค.

๊ฒฝ๊ณ  ์‚ฌํ•ญ:

โ€“ ์ œ์„ธ๋™์€ ์ œ์„ธ๋™๊ธฐ ์ปค๋„ฅํ„ฐ์—์„œ๋งŒ ์‹ค์‹œํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๊ฐ€ ์žฅ์ฐฉ๋˜์–ด ์žˆ์ง€ ์•Š์€ ๊ฒฝ์šฐ์—๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์ œ์„ธ๋™์„ ์‹ค์‹œํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

ํ˜ˆ์•• ์ปคํ”„ ์—ฐ๊ฒฐ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋Š” ๋งž์ถคํ˜• ํ˜ˆ์•• ์ปคํ”„์™€ ํ•จ๊ป˜ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์‚ฌ์šฉ ์ „ Link Box ๋’ท๋ฉด์— ์žˆ๋Š” ํฐ์ƒ‰ BP ์ปค๋„ฅํ„ฐ์— ํŠœ๋ธŒ๋ฅผ ์—ฐ๊ฒฐํ•˜์‹ญ์‹œ์˜ค.

์ฐธ๊ณ : ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ํ˜ˆ์••์šฉ ์Šคํ”ผ์ปค๋Š” ์•„๋ž˜ ๋™๊ทธ๋ผ๋ฏธ๋กœ ํ‘œ์‹œ๋œ ์™ผํŒ” ์˜ค๊ธˆ์— ์žˆ์Šต๋‹ˆ๋‹ค. ์š”๊ณจ ๋ฐ ์ƒ์™„ ๋งฅ๋ฐ•์€ ์‚ฌ๊ฐํ˜•์œผ๋กœ ํ‘œ์‹œ๋œ ๋ถ€๋ถ„์— ์žˆ์Šต๋‹ˆ๋‹ค.

LLEAP์—์„œ ํ˜ˆ์•• ์ปคํ”„ ๋ณด์ •

1. ๋ฉ”๋‰ด์—์„œ <๋„๊ตฌ>๋ฅผ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

2. ๋„๊ตฌ ๋ฉ”๋‰ด์—์„œ <์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

3. ํ•˜์œ„ ๋ฉ”๋‰ด์—์„œ <ํ˜ˆ์•• ๋ณด์ •>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

4. ์Šคํฌ๋ฆฐ ๋งˆ๋ฒ•์‚ฌ ์ง€์‹œ๋ฅผ ๋”ฐ๋ผ ๋ณด์ •์„ ์ˆ˜ํ–‰ํ•ฉ๋‹ˆ๋‹ค.

SimPad์—์„œ ํ˜ˆ์•• ์ปคํ”„ ๋ณด์ •

1. ๋ฉ”๋‰ด์—์„œ <๋ณด์ •>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

2. ๋“œ๋กญ๋‹ค์šด ๋ฉ”๋‰ด์—์„œ <BP ๋ณด์ •>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

3. ์Šคํฌ๋ฆฐ ๋งˆ๋ฒ•์‚ฌ ์ง€์‹œ๋ฅผ ๋”ฐ๋ผ ๋ณด์ •์„ ์ˆ˜ํ–‰ํ•ฉ๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •

Page 233: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

231

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

๋™๊ณต ๊ต์ฒด

SimJunior๋Š” ๋ˆˆ์— ์‚ฝ์ž…๋˜์–ด ์žˆ๋Š” ์ •์ƒ ์‚ฌ์ด์ฆˆ์˜ ๋™๊ณต๊ณผ ํ•จ๊ป˜ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ํ”Œ๋ผ์Šคํ‹ฑ ๋™๊ณต ์žฅ์ฐฉ๋ฌผ(์ •์ƒ, ์‚ฐ๋Œ€, ์ถ•๋™)์ด ํฌํ•จ๋œ ๊ฐœ๋ณ„ ํ‚คํŠธ๊ฐ€ SimJunior์™€ ํ•จ๊ป˜ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค.

๋™๊ณต ๊ต์ฒด ๋ฐฉ๋ฒ•:

1. ๋ˆˆ๊บผํ’€์„ ์กฐ์‹ฌ์Šค๋Ÿฝ๊ฒŒ ๋„“๊ฒŒ ๋ฒŒ๋ฆฝ๋‹ˆ๋‹ค. ์ด๋•Œ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์–ผ๊ตด ํ”ผ๋ถ€๊ฐ€ ์ฐข์–ด์ง€์ง€ ์•Š๋„๋ก ์ฃผ์˜ํ•ฉ๋‹ˆ๋‹ค.

2. ํ‚คํŠธ์— ์ œ๊ณต๋œ ํก์ž…์šฉ ์ปต ํˆด์ด๋‚˜ ์†ํ†ฑ์˜ ๋ ๋ถ€๋ถ„์„ ์‚ฌ์šฉํ•ด ๋ˆˆ์—์„œ ๋™๊ณต์„ ์กฐ์‹ฌ์Šค๋Ÿฝ๊ฒŒ ๊บผ๋ƒ…๋‹ˆ๋‹ค.

3. ํก์ž…์šฉ ์ปต ํˆด์„ ์‚ฌ์šฉํ•˜๊ฑฐ๋‚˜ ์ž๋ฆฌ์— ๋งž๊ฒŒ ๋ถ€๋“œ๋Ÿฝ๊ฒŒ ๋ˆŒ๋Ÿฌ ๋™๊ณต์„ ์›ํ•˜๋Š” ์žฅ์ฐฉ๋ฌผ๋กœ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ ์‚ฌ์šฉ

์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋ฅธ์ชฝ ์ธก๋ฉด์—์„œ ๋‚˜์˜ค๋Š” ์ผ€์ด๋ธ” ๋ฌถ์Œ์— ์žˆ๋Š” ํˆฌ๋ช… ํŠœ๋ธŒ์— ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค. ์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ๋ฅผ ์‚ฌ์šฉํ•  ๋•Œ SimPad๋‚˜ LLEAP์—์„œ ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ๋ฅผ ๋Œ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

SimJunior์™€ ํ˜ธํ™˜๋˜๋Š” ์™ธ๋ถ€ ์ปดํ”„๋ ˆ์„œ ๋ฐ ์ œ์–ด ์žฅ์น˜ ํŒจ๋„์— ๋Œ€ํ•œ ๋ณด๋‹ค ์ž์„ธํ•œ ์ •๋ณด๋Š” ํ˜„์ง€ Laerdal ๋Œ€๋ฆฌ์ ์— ์—ฐ๋ฝํ•˜์‹œ๊ธฐ ๋ฐ”๋ž๋‹ˆ๋‹ค.

SimPad์—์„œ ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ ์ผœ๊ฑฐ๋‚˜ ๋„๊ธฐ

1. <์ˆ˜๋™ ๋ชจ๋“œ>๋ฅผ ์‹œ์ž‘ํ•˜๊ณ  ์ฃผ์ œ(ํ…Œ๋งˆ)๋ฅผ ์„ ํƒํ•œ ๋‹ค์Œ ์„ธ์…˜์„ ์‹œ์ž‘ํ•ฉ๋‹ˆ๋‹ค.

2. ํ•˜๋‹จ ๋ฉ”๋‰ด์—์„œ <๊ธฐํƒ€>๋ฅผ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

3. ํ•˜์œ„ ๋ฉ”๋‰ด์—์„œ <์ปดํ”„๋ ˆ์„œ>๋ฅผ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

4. ๋Œ€ํ™” ์ƒ์ž์—์„œ ์›ํ•˜๋Š” ๋ณ€๊ฒฝ์„ ํ•œ ๋‹ค์Œ ํ™•์ธ์„ ํด๋ฆญํ•ฉ๋‹ˆ๋‹ค.

LLEAP์—์„œ ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ ์ผœ๊ฑฐ๋‚˜ ๋„๊ธฐ

1. ๋ฉ”๋‰ด์—์„œ <๋„๊ตฌ>๋ฅผ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

2. ๋„๊ตฌ ๋ฉ”๋‰ด์—์„œ <์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •>์„ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

3. ํ•˜์œ„ ๋ฉ”๋‰ด์—์„œ <๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ>๋ฅผ ์„ ํƒํ•ฉ๋‹ˆ๋‹ค.

4. ๋Œ€ํ™” ์ƒ์ž์—์„œ ์›ํ•˜๋Š” ๋ณ€๊ฒฝ์„ ํ•œ ๋‹ค์Œ ํ™•์ธ์„ ํด๋ฆญํ•ฉ๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์ •

Page 234: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

232

์ฐธ๊ณ : ์˜ˆ๋น„ ๋ถ€ํ’ˆ์— ๋Œ€ํ•œ ์ •๋ณด๋Š” "์˜ˆ๋น„ ๋ถ€ํ’ˆ ๋ฐ ๋ถ€์†ํ’ˆ" ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

๋ณด๊ด€ ๋˜๋Š” ๋ฐฐ์†ก ์ „

โ€“ IV ํŒ”์„ 60% ์ด์†Œํ”„๋กœํŒ์˜ฌ ์•Œ์ฝ”์˜ฌ, ๋˜๋Š” 70% ์—ํƒ„์˜ฌ๋กœ ์„ธ์ฒ™ํ•ฉ๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋ฅธ์ชฝ ๋ฐœ ๋ฐ”๋‹ฅ๋ฉด์— ์žˆ๋Š” ๋ฐฐ์ˆ˜ ๋ฐธ๋ธŒ๋ฅผ ์—ฝ๋‹ˆ๋‹ค.

๊ฐ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ์„ธ์…˜ ํ›„ ์œ ์ง€ ๊ด€๋ฆฌ

๋‹ค์Œ ์˜ˆ๋ฐฉ ์กฐ์น˜๋“ค์€ SimJunior ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค๋žœ ์ˆ˜๋ช…์„ ๋ณด์žฅํ•˜๊ธฐ ์œ„ํ•ด ํ•„์š”ํ•ฉ๋‹ˆ๋‹ค.

โ€“ SimPad, Link Box ๋ฐ PC์˜ ์ „์›์„ ๋•๋‹ˆ๋‹ค.

โ€“ ํ•„์š”ํ•œ ๊ฒฝ์šฐ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•ฉ๋‹ˆ๋‹ค.

โ€“ IV ํŒ” ์‹œ์Šคํ…œ์„ ์„ธ์ฒ™ํ•˜๊ณ  IO ๋‹ค๋ฆฌ์˜ ์•ก์ฒด๋ฅผ ๋นผ๋ƒ…๋‹ˆ๋‹ค (IO ๋‹ค๋ฆฌ ๋ฐ”๋‹ฅ๋ฉด์˜ ํ”Œ๋Ÿฌ๊ทธ๋ฅผ ๊ฐœ๋ฐฉํ•œ ์ƒํƒœ๋กœ ๋†“์•„ ๋‘ก๋‹ˆ๋‹ค).

โ€“ IV ํŒ”์„ ์‚ฌ์šฉํ•œ ์„ธ์…˜ ํ›„์—๋Š” 60% ์ด์†Œํ”„๋กœํŒ์˜ฌ ์•Œ์ฝ”์˜ฌ ๋˜๋Š” 70% ์—ํƒ„์˜ฌ๋กœ IV ํŒ”์„ ์„ธ์ฒ™ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์ –์€ ํ—๊ฒŠ์œผ๋กœ ํ”ผ๋ถ€๋ฅผ ๋‹ฆ์Šต๋‹ˆ๋‹ค.

โ€“ ์ –์€ ์˜๋ณต์ด๋‚˜ ์ด๋ถˆ์„ ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค.

โ€“ ํ…Œ์ดํ”„ ์ž”์—ฌ๋ฌผ์„ ์Šต๊ธฐ๊ฐ€ ์žˆ๋Š” ์ฒœ์ด๋‚˜ ์†Œ๋…์šฉ ์•Œ์ฝ”์˜ฌ๋กœ ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์‚ฌ์šฉ์— ๋”ฐ๋ผ ์†Œ๋ชจ๋˜์—ˆ๊ฑฐ๋‚˜ ์†์ƒ๋œ ๋ชจ๋“ˆ์„ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์œก์•ˆ์œผ๋กœ ์†์ƒ์ด ํ™•์ธ๋˜๋Š” ์ผ€์ด๋ธ” ๋˜๋Š” ์ปค๋„ฅํ„ฐ๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

โ€“ ์ž๊ฒฉ์„ ๊ฐ–์ถ˜ ๋‹ด๋‹น์ž์—๊ฒŒ ์ •๊ธฐ์ ์œผ๋กœ ์„œ๋น„์Šค๋ฅผ ๋ฐ›์•„์•ผ ํ•ฉ๋‹ˆ๋‹ค.

๋‹ค์Œ๊ณผ ๊ฐ™์€ ๊ฒฝ์šฐ์— ํ•ญ์ƒ ์ •๋น„๋ฅผ ์‹ค์‹œํ•˜์‹ญ์‹œ์˜ค.

โ€“ ์•ก์ฒด๊ฐ€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ๋‚ด ์™ธ๋ถ€๋กœ ์œ ์ถœ๋œ ๊ฒฝ์šฐ

โ€“ ๋จผ์ง€๊ฐ€ ๋งŽ์€ ํ™˜๊ฒฝ์—์„œ ์‚ฌ์šฉํ•œ ํ›„

์œ ์ง€ ๊ด€๋ฆฌ

Page 235: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

233

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

์ƒ๋ฐ˜์‹  ์—ด๊ธฐ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒ๋ฐ˜์‹ ์„ ์—ด์–ด ๋‹ค์Œ๊ณผ ๊ฐ™์€ ์ ˆ์ฐจ๋ฅผ ์ˆ˜ํ–‰ํ•ฉ๋‹ˆ๋‹ค.

โ€“ ํŒ”๋‹ค๋ฆฌ ๋ถ€์ฐฉ ๋˜๋Š” ๊ต์ฒด

โ€“ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ๊ต์ฒด

โ€“ ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ ๋ฐ ํ ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด

โ€“ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€ ๊ต์ฒด

โ€“ ์ผ๋ฐ˜์ ์ธ ์ ๊ฒ€

๊ฒฝ๊ณ : ์ƒ๋ฐ˜์‹ ์„ ์™ผ์ชฝ์—์„œ ์˜ค๋ฅธ์ชฝ ๋ฐฉํ–ฅ์œผ๋กœ ์—ด๊ณ , ํ”ผ๋ถ€๋ฅผ ๋ถ€๋“œ๋Ÿฝ๊ฒŒ ๋–ผ์–ด๋ƒ…๋‹ˆ๋‹ค. ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๋“ค๋ ค๊ณ  ๋„ˆ๋ฌด ์„ธ๊ฒŒ ์žก์•„๋‹น๊ธฐ์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ์ด๋Š” ํ‰๋ถ€ ์ผ€์ด๋ธ”์„ ์†์ƒ์‹œํ‚ฌ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

1. ์ƒ๋ฐ˜์‹  ์™ผ์ชฝ๊ณผ ๊ฐ ์–ด๊นจ์— ์žˆ๋Š” ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€ ํ™€๋”๋ฅผ ๋–ผ์–ด๋ƒ…๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ๊ต์ฒด

1. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒ๋ฐ˜์‹ ์„ ์—ฝ๋‹ˆ๋‹ค.

2. ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ์˜ค๋ฅธ์ชฝ์œผ๋กœ ์ ‘์Šต๋‹ˆ๋‹ค.

3. ์ œ์„ธ๋™ ์ปค๋„ฅํ„ฐ ์ผ€์ด๋ธ”์„ ๋ถ„๋ฆฌํ•ฉ๋‹ˆ๋‹ค.

4. ์ œ์„ธ๋™ ์ปค๋„ฅํ„ฐ ์ผ€์ด๋ธ”์€ ํ‰๋ถ€ ํผ ์•„๋ž˜์˜ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์˜ค๋ฅธ์ชฝ์—์„œ ๋ถ„๋ฆฌํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

์ฐธ๊ณ : ์œ„์žฅ๊ด€ ์Šคํฐ์ง€๋ฅผ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์—ฐ๊ฒฐํ•˜๋Š” ํŠœ๋ธŒ์™€ ์ผ€์ด๋ธ”์„ ๋ถ„๋ฆฌํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

5. 1~4๋‹จ๊ณ„๋ฅผ ์—ญ์ˆœ์œผ๋กœ ์ˆ˜ํ–‰ํ•˜์—ฌ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๊ต์ฒดํ•˜์‹ญ์‹œ์˜ค.

2. ๋ฐฐํ„ฐ๋ฆฌ ์ŠคํŠธ๋žฉ์—์„œ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ๊บผ๋ƒ…๋‹ˆ๋‹ค.

3. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋‚ด๋ถ€์—์„œ๋ถ€ํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ์ „์› ์—ฐ๊ฒฐ์„ ์œ„๋กœ ๋‹น๊น๋‹ˆ๋‹ค. ๋ฐฐํ„ฐ๋ฆฌ ์ „์› ์—ฐ๊ฒฐ์„ ๋–ผ์–ด๋ƒ…๋‹ˆ๋‹ค.

4. ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ๋“ค์–ด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ ๊บผ๋ƒ…๋‹ˆ๋‹ค.

5. ์ถฉ์ „์ด ์™„๋ฃŒ๋œ ๋ฐฐํ„ฐ๋ฆฌ๋กœ ๊ต์ฒดํ•˜๊ฑฐ๋‚˜ Laerdal์ด ์Šน์ธํ•œ ์ƒˆ๋กœ์šด SimJunior ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์„ค์น˜ํ•ฉ๋‹ˆ๋‹ค.

6. ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค.

7. ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

์œ ์ง€ ๊ด€๋ฆฌ

Page 236: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

234

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ๋Š” ์ž‘๋™์„ ํ•˜๋ฉฐ ์ž๊ฐ€ ์ถฉ์ „ํ•ฉ๋‹ˆ๋‹ค. ํ•„์š”ํ•œ ๊ฒฝ์šฐ, ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ๋Š” ์„ ํƒ ์‚ฌ์–‘์ธ ์™ธ๋ถ€ ์ „์› ์–ด๋Œ‘ํ„ฐ๋ฅผ ์‚ฌ์šฉํ•ด ์ถฉ์ „ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

1. Link Box๋ฅผ ํ†ตํ•ด ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์ „์›์„ ๋•๋‹ˆ๋‹ค.

2. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ ๊บผ๋ƒ…๋‹ˆ๋‹ค.

3. (ํ˜„์ง€ ๊ทœ๊ฒฉ์— ๋ถ€ํ•ฉํ•˜๋Š” ์ „์› ์ฝ”๋“œ๊ฐ€ ์žˆ๋Š”) ์Šน์ธ๋œ ์™ธ๋ถ€ ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „๊ธฐ๋ฅผ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๋ฐฐํ„ฐ๋ฆฌ ํ•˜๋‹จ์— ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค. ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „๊ธฐ์˜ ์ „์„ ์„ ๋ฒฝ๋ฉด ์ฝ˜์„ผํŠธ์— ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค.

4. ์ถฉ์ „์ด ์™„๋ฃŒ๋œ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ๋ฐฐํ„ฐ๋ฆฌ์™€ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด

ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ๋Š” ํ‰๋ถ€ ํŒ์˜ ์•„๋ž˜์ชฝ ๋๋ถ€๋ถ„, ํ ์•„๋ž˜ ์ค‘์•™์— ์žˆ์Šต๋‹ˆ๋‹ค.

1. ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ์—ด์–ด ๊ฐ€์ŠดํŒ์„ ๋…ธ์ถœ์‹œํ‚ต๋‹ˆ๋‹ค. ์ƒ๋ฐ˜์‹  ์—ด๊ธฐ๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

2. ํ ์ฃผ๋จธ๋‹ˆ์—์„œ ํˆฌ๋ช… ํŠœ๋ธŒ์˜ ์—ฐ๊ฒฐ์„ ๋Š๊ณ  ํ ์ฃผ๋จธ๋‹ˆ๋ฅผ ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค. ์ž์„ธํ•œ ๋‚ด์šฉ์€ ํ ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด ๋‹จ์›์„ ์ฐธ์กฐํ•ฉ๋‹ˆ๋‹ค.

3. ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ์—์„œ ํˆฌ๋ช… ํŠœ๋ธŒ์˜ ์—ฐ๊ฒฐ์„ ๋ถ„๋ฆฌํ•ฉ๋‹ˆ๋‹ค.

4. ์‚ฌ์šฉํ•œ ์ฃผ๋จธ๋‹ˆ๋ฅผ ํ๊ธฐํ•ฉ๋‹ˆ๋‹ค.

5. ์ƒˆ ์ฃผ๋จธ๋‹ˆ๋ฅผ ์‚ฝ์ž…ํ•ฉ๋‹ˆ๋‹ค.

6. ์ƒˆ๋กœ์šด ์ฃผ๋จธ๋‹ˆ์— ํŠœ๋ธŒ๋ฅผ ๋‹ค์‹œ ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค.

7. ์ƒ๋ฐ˜์‹ ์„ ๋‹ซ๊ณ  ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

ํ ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด

๋ˆ„์ˆ˜๊ฐ€ ๋ฐœ์ƒํ•˜๋ฉด ํ ์ฃผ๋จธ๋‹ˆ(ํ‰๋ถ€ ๊ตฌ๋ฉ ๋‚ด์— ์œ„์น˜)๋ฅผ ๊ต์ฒดํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

1. ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€ ์—ด๊ธฐ.

2. ํˆฌ๋ช… ํŠœ๋ธŒ๋ฅผ ํ ์ฃผ๋จธ๋‹ˆ์˜ ๊ฐ ์ธก๋ฉด ์•„๋ž˜์—์„œ ๋ถ„๋ฆฌํ•ฉ๋‹ˆ๋‹ค. ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ ๊ต์ฒดํ•˜๊ธฐ์˜ 2๋‹จ๊ณ„ ์‚ฌ์ง„์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

3. ์ƒ๋‹จ ์ค‘์•™์—์„œ ํ ์ฃผ๋จธ๋‹ˆ ํด๋ฆฝ์„ ๋ถ„๋ฆฌํ•ฉ๋‹ˆ๋‹ค.

4. ํ ์ฃผ๋จธ๋‹ˆ์˜ ์ƒ๋‹จ ์ค‘์•™ ๋ถ€๋ถ„์„ ์†Œ์ผ“์—์„œ ๋ถ€๋“œ๋Ÿฝ๊ฒŒ ๋‹น๊ฒจ ๋ฝ‘์Šต๋‹ˆ๋‹ค.

5. ์ ˆ์ฐจ๋ฅผ ์—ญ์ˆœ์œผ๋กœ ์ˆ˜ํ–‰ํ•˜์—ฌ ์ƒˆ๋กœ์šด ํ ์ฃผ๋จธ๋‹ˆ๋ฅผ ์„ค์น˜ํ•ฉ๋‹ˆ๋‹ค.

์œ ์ง€ ๊ด€๋ฆฌ

Page 237: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

235

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€ ๊ต์ฒด

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํ”ผ๋ถ€๋Š” ์ฐข์–ด์ง€๊ฑฐ๋‚˜ ๊ตฌ๋ฉ์ด ๋‚˜๊ฑฐ๋‚˜ ์–ผ๋ฃฉ์ด ๋ฌป์œผ๋ฉด ๊ต์ฒดํ•ด์•ผ ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€:

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ƒ๋ฐ˜์‹  ํ”ผ๋ถ€๋ฅผ ๊ต์ฒดํ•˜๋ ค๋ฉด ์ƒ๋ฐ˜์‹  ์—ด๊ธฐ ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

ํŒ” ํ”ผ๋ถ€:

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํŒ” ํ”ผ๋ถ€๋ฅผ ๊ต์ฒดํ•˜๋Š” ๋ฐฉ๋ฒ•:

1. ๋‚ก์€ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ํŒ” ํ”ผ๋ถ€๋ฅผ ํŒ”๊ณผ ์†์—์„œ ๋ถ„๋ฆฌ์‹œํ‚ค๊ฑฐ๋‚˜ ํ”ผ๋ถ€๋ฅผ *์ž˜๋ผ ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค.

์ƒˆ๋กœ์šด ํŒ”์„ ๋ถ€์ฐฉํ•˜๋Š” ๋ฐฉ๋ฒ•:

์˜ค๋ฅธ์ชฝ IV ํŒ” ๊ต์ฒด

1. ์ƒ๋ฐ˜์‹  ์—ด๊ธฐ ๋‹จ์›์„ ์ฐธ์กฐํ•˜์—ฌ ์ƒ๋ฐ˜์‹ ์„ ์—ฝ๋‹ˆ๋‹ค.

2. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์–ด๊นจ์— ํŒ”์„ ๊ณ ์ •์‹œํ‚ค๋Š” ๋ณผํŠธ๋ฅผ ํ’€์–ด ๋‚ก์€ ํŒ”์„ ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค.

3. ์–ด๊นจ์˜ ๋‚˜์‚ฌ๋ฅผ ํ—๊ฒ๊ฒŒ ํ•˜์—ฌ ์–ด๊นจ ์ถ•์„ ์‰ฝ๊ฒŒ ๋นผ๋‚ผ ์ˆ˜ ์žˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

4. ๋‚ก์€ ํŒ”์„ ๋ช…์‹œ๋œ ์ง€์นจ์— ๋”ฐ๋ผ ํ๊ธฐํ•ฉ๋‹ˆ๋‹ค.

1. ํŒ”์˜ ์ถ•์ด ์ œ์ž๋ฆฌ์— ์‰ฝ๊ฒŒ ๋ฐ€๋ ค ๋“ค์–ด๊ฐˆ ์ˆ˜ ์žˆ๋„๋ก ๊ฒฌ๊ด€์ ˆ ๋‚˜์‚ฌ๊ฐ€ ์ถฉ๋ถ„ํžˆ ๋Š์Šจํ•œ์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค.

2. ์ƒ๋ฐ˜์‹ ์˜ ํ•ด๋‹น ์—ฐ๊ฒฐ์ ์— ์–ด๊นจ๋ฅผ ์—ฐ๊ฒฐํ•ฉ๋‹ˆ๋‹ค.

3. ์ถ•์ด ๊ฒฌ๊ด€์ ˆ ๋ธŒ๋ผ์ผ“ ๋‚ด๋ถ€์™€ ์ด์–ด์ง€๋„๋ก ๊ฒฌ๊ด€์ ˆ ๋ธŒ๋ผ์ผ“ ์•ˆ์œผ๋กœ ํŒ” ์ถ•์„ ์กฐ์‹ฌ์Šค๋Ÿฝ๊ฒŒ ๋ฐ€์–ด ๋„ฃ์Šต๋‹ˆ๋‹ค.

4. Allen ๋‚˜์‚ฌ์šฉ ์ŠคํŒจ๋„ˆ๋ฅผ ์‚ฌ์šฉํ•ด ์–ด๊นจ ๋‚˜์‚ฌ๋ฅผ ์กฐ์ž…๋‹ˆ๋‹ค.

์˜ค๋ฅธ์ชฝ IO ๋‹ค๋ฆฌ ๊ต์ฒด ์˜ค๋ฅธ์ชฝ ๋‹ค๋ฆฌ ํ•˜๋‹จ์„ ๋–ผ์–ด๋‚ด๋Š” ๋ฐฉ๋ฒ•:

1. ๋‹ค๋ฆฌ ๋‚ด์˜ ์•ก์ฒด๋Š” ๋ชจ๋‘ ๋ฐฐ์ˆ˜๋˜๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

2. ๋„“์ ๋‹ค๋ฆฌ์— ๋‚ก์€ IO ๋‹ค๋ฆฌ๋ฅผ ๊ณ ์ •์‹œํ‚ค๋Š” ๋ณผํŠธ๋ฅผ ํ’€์–ด ์ œ๊ฑฐํ•ฉ๋‹ˆ๋‹ค.

3. IO ๋‹ค๋ฆฌ ํ•˜๋‹จ์„ ๋„“์ ๋‹ค๋ฆฌ์—์„œ ๋นผ๋ƒ…๋‹ˆ๋‹ค.

4. ๋‚ก์€ IO ๋‹ค๋ฆฌ๋ฅผ ๋ช…์‹œ๋œ ์ง€์นจ์— ๋”ฐ๋ผ ํ๊ธฐํ•ฉ๋‹ˆ๋‹ค.

์œ„์˜ ์ ˆ์ฐจ๋ฅผ ์—ญ์ˆœ์œผ๋กœ ์ˆ˜ํ–‰ํ•˜์—ฌ ์ƒˆ๋กœ์šด IO ๋‹ค๋ฆฌ๋ฅผ ๋ถ€์ฐฉํ•ฉ๋‹ˆ๋‹ค.

๊ฒฝ๊ณ : *์‹ฌ์ถ•(Mandrel) ํŒ”์— ๊ตฌ๋ฉ์„ ๋‚ด๊ฑฐ๋‚˜ ์ž๋ฅด์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

2. ๋‚ก์€ ํ”ผ๋ถ€๋ฅผ ํ๊ธฐํ•ฉ๋‹ˆ๋‹ค.

3. ๋ฌผ์„ ํ˜ผํ•ฉํ•œ ์ค‘์„ฑ ์„ธ์ œ๋กœ ์ƒˆ๋กœ์šด ํŒ” ํ”ผ๋ถ€์˜ ๋‚ด๋ถ€๋ฅผ ๋งค๋„๋Ÿฝ๊ฒŒ ํ•ฉ๋‹ˆ๋‹ค.

4. ๋ฌผ์„ ํ˜ผํ•ฉํ•œ ์ค‘์„ฑ ์„ธ์ œ๋กœ ์‹ฌ์ถ•(Mandrel)์„ ๋งค๋„๋Ÿฝ๊ฒŒ(๋˜๋Š” ๋น„๋ˆ„ ๊ฑฐํ’ˆ์งˆ) ํ•ฉ๋‹ˆ๋‹ค.

5. ํ”ผ๋ถ€ ์•ˆ์œผ๋กœ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์†์„ ๋ฐ€์–ด ๋„ฃ์Šต๋‹ˆ๋‹ค

6. ์žฅ๊ฐ‘์„ ๋ผ์šฐ๋“ฏ์ด ์†๊ฐ€๋ฝ๋“ค์„ ํ”ผ๋ถ€์— ๋ผ์›๋‹ˆ๋‹ค.

7. ํŒ” ์‹ฌ์ถ•(Mandrel)์— ํ”ผ๋ถ€๋ฅผ ์ž…ํž™๋‹ˆ๋‹ค.

์œ ์ง€ ๊ด€๋ฆฌ

Page 238: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

236

์‹œ์Šคํ…œ ์„ค์น˜

๋ฌธ์ œ

โ€ข ๋ฐ์ดํ„ฐ ์†์‹ค ๋˜๋Š” ์ „์ฒด ์‹œ์Šคํ…œ ์žฅ์• (์ผ๋ฐ˜์  ์‹œ์Šคํ…œ ์žฅ์• ).

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ์‹œ์Šคํ…œ์ด ์ •์ง€๋˜๊ฑฐ๋‚˜ ๋ชจ๋“  ๋ฐ์ดํ„ฐ๊ฐ€ ์†์‹ค ๋˜๋Š” ์†์ƒ๋œ ๊ฒฝ์šฐ์—๋Š” ํ˜„์ง€ Laerdal ์„œ๋น„์Šค ์„ผํ„ฐ์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

LLEAPโ€ข ์†Œํ”„ํŠธ์›จ์–ด ๋„์›€๋ง ํŒŒ์ผ > LLEAP > ๋ฌธ์ œ ํ•ด๊ฒฐ ๊ฐ€์ด๋“œ๋ฅผ

์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค. (๋„์›€๋ง์€ Laerdal Simulation Home์—์„œ ์•ก์„ธ์Šค ๊ฐ€๋Šฅ)

Laerdal Patient Monitorโ€ข ์†Œํ”„ํŠธ์›จ์–ด ๋„์›€๋ง ํŒŒ์ผ > Laerdal Patient Monitor > ๋ฌธ์ œ

ํ•ด๊ฒฐ ๊ฐ€์ด๋“œ๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค. (๋„์›€๋ง์€ Laerdal Simulation Home์—์„œ ์•ก์„ธ์Šค ๊ฐ€๋Šฅ)

๋””๋ธŒ๋ฆฌํ•‘ ๋ฐ ๋น„๋””์˜ค ๋…นํ™”

โ€ข SimView ๋„์›€๋ง(SimView ํ™”๋ฉด ํ•˜๋‹จ ๋งํฌ์—์„œ ์•ก์„ธ์Šค ๊ฐ€๋Šฅ)์˜ ๋ฌธ์ œ ํ•ด๊ฒฐ ๋‹จ์›์ด๋‚˜ Session Viewer ๋„์›€๋ง(Laerdal Simulation Home์—์„œ ์•ก์„ธ์Šค ๊ฐ€๋Šฅ)์˜ ๋ฌธ์ œ ํ•ด๊ฒฐ ๊ฐ€์ด๋“œ๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ

๋ฌธ์ œ

โ€ข ์˜ˆ์ƒ์น˜ ๋ชปํ•œ ํ–‰๋™.

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์˜ ์˜ค์ž‘๋™์€ ์ผ€์ด๋ธ”, ํŠœ๋ธŒ ๋˜๋Š” ์ปค๋„ฅํ„ฐ๊ฐ€ ๋Š์Šจํ•ด ๋ฐœ์ƒํ•  ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค. ์ƒ๋ฐ˜์‹ ์„ ์—ด๊ณ  ๋ถ„๋ฆฌ๋˜์—ˆ๊ฑฐ๋‚˜ ๋ˆ„์ถœ์ด ๋ฐœ์ƒํ•œ ํ•ญ๋ชฉ์ด ์žˆ๋Š”์ง€ ์ ๊ฒ€ํ•ฉ๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ค์น˜ - ์ƒ๋ฐ˜์‹  ์—ด๊ธฐ ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

โ€ข ์ˆ˜์•ก์ด ๋ˆ„์ถœ๋˜๋Š” ๊ฒฝ์šฐ์—๋Š” ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ „์›์„ ๋„๊ณ  Laerdal ๊ธฐ์ˆ  ์„œ๋น„์Šค์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

๊ธฐ๋„ ์˜ค์—ผ

๋ฌธ์ œ

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ธฐ๋„๊ฐ€ ๊ตฌ๊ฐ• ๋Œ€ ๊ตฌ๊ฐ• ๊ตฌ์กฐ ํ˜ธํก์œผ๋กœ ์ธํ•ด ์˜ค์—ผ๋˜์—ˆ์Šต๋‹ˆ๋‹ค.

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ธ์ฒ™์ œ๋กœ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์™ธ๋ถ€๋ฅผ ์„ธ์ฒ™ํ•ฉ๋‹ˆ๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ธ์ฒ™์ œ๋กœ ๊ตฌ๊ฐ• ๋‚ด๋ถ€๋ฅผ ์„ธ์ฒ™ํ•ฉ๋‹ˆ๋‹ค. ํ ์ฃผ๋จธ๋‹ˆ๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค. ์œ ์ง€๊ด€๋ฆฌ - ํ ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

ํ‰๋ถ€ ์›€์ง์ž„

๋ฌธ์ œ

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ ํ‰๋ถ€๊ฐ€ ์ƒ์Šน๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋ฅผ ์—ฐ๊ฒฐํ•˜๋Š” ์ „์›์ด ์ผœ์ ธ ์žˆ๋Š”์ง€ ์ ๊ฒ€ํ•ฉ๋‹ˆ๋‹ค.

โ€ข SimPad ๋˜๋Š” LLEAP์—์„œ ๋‹ค์Œ์„ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค.

โ€“ awRR์ด 0์œผ๋กœ ์„ค์ •๋˜์–ด ์žˆ์ง€ ์•Š์€์ง€

โ€“ ํ‰๋ถ€ ์ƒ์Šน์ด OFF๋กœ ์„ค์ •๋˜์–ด ์žˆ์ง€ ์•Š์€์ง€

โ€“ ECG๊ฐ€ ๊ด€๋ฅ˜ ๋ฆฌ๋“ฌ์œผ๋กœ ์„ค์ •๋˜์–ด ์žˆ๋Š”์ง€

โ€“ ์ตœ๋Œ€ ๊ณต๊ธฐ ์ €ํ•ญ ๋˜๋Š” ํ›„๋‘ ๋ฐœ์ž‘๊ณผ ๊ฐ™์€ ๊ธฐ๋„ ํ•ฉ๋ณ‘์ฆ์ด ์„ค์ •๋˜์–ด ์žˆ์ง€ ์•Š์€์ง€

โ€“ ์ปดํ”„๋ ˆ์„œ๊ฐ€ LLEAP์—์„œ ํ™œ์„ฑํ™”๋˜์—ˆ๋Š”์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค. ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ ๋„๊ธฐ ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

โ€ข ์™ธ๋ถ€ ์••์ถ• ๊ณต๊ธฐ ๊ณต๊ธ‰์›์ด ๋ชจ๋‘ ๊บผ์ ธ ์žˆ์œผ๋ฉฐ ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์—์„œ ๊ณต๊ธฐ ํŠœ๋ธŒ๊ฐ€ ๋ถ„๋ฆฌ๋˜์–ด ์žˆ๋Š”์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค.

โ€ข ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ๊ฐ€ ๊ณผ์—ด๋  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹๋„๋ก ์•ฝ 20๋ถ„๊ฐ„ ๊ธฐ๋‹ค๋ฆฝ๋‹ˆ๋‹ค.

โ€ข ํ‰๋ถ€ ์ƒ์Šน์ด ์–‘์ชฝ์œผ๋กœ ์„ค์ •๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค(์˜ˆ๋ฅผ ๋“ค์–ด, ET-ํŠœ๋ธŒ๊ฐ€ ๊ธฐ๊ด€์ง€์— ๋„ˆ๋ฌด ๊นŠ์ด ์‚ฝ์ž…๋˜์–ด ์žˆ๋Š” ๊ฒฝ์šฐ).

โ€ข ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ๊ฐ€ ๋ˆ„์ˆ˜๋˜๊ฑฐ๋‚˜, ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ๋ฅผ ์—ฐ๊ฒฐํ•˜๋Š” ํŠœ๋ธŒ๊ฐ€ ๋น„ํ‹€์–ด์ ธ ์žˆ๊ฑฐ๋‚˜, ๊ผฌ์—ฌ ์žˆ๊ฑฐ๋‚˜, ์—ฐ๊ฒฐ์ด ๋Š์–ด์ ธ ์žˆ์Šต๋‹ˆ๋‹ค. ๋ˆ„์ถœ์ด ์žˆ์„ ๊ฒฝ์šฐ ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค. ์œ ์ง€๊ด€๋ฆฌ - ํ‰๋ถ€ ์ƒ์Šน ์ฃผ๋จธ๋‹ˆ ๊ต์ฒด๊ธฐ ๋‹จ์›์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.

โ€ข ๊ณต๊ธฐ ํŠœ๋ธŒ์— ๋ˆ„์ถœ์ด ์žˆ๋Š”์ง€ ์ ๊ฒ€ํ•˜๊ณ , ๋ชจ๋“  ์—ฐ๊ฒฐ๋ถ€๊ฐ€ ์ •์ƒ์ธ์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค. ๋ˆ„์ถœ์ด ์žˆ๋Š” ๊ฒฝ์šฐ์—๋Š” ํŠœ๋ธŒ ๋ถ€์œ„๋ฅผ ๊ต์ฒดํ•ฉ๋‹ˆ๋‹ค.

โ€ข ํ‰๋ถ€ ์›€์ง์ž„์ด ์–•๊ณ  ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ๊ฐ€ ๊ณ„์† ๊ตฌ๋™๋ฉ๋‹ˆ๋‹ค. ๋‚ด๋ถ€ ์ปดํ”„๋ ˆ์„œ๊ฐ€ ๋งˆ๋ชจ๋˜์—ˆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. Laerdal ๊ธฐ์ˆ  ์„œ๋น„์Šค์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

ํ

๋ฌธ์ œ

โ€ข ํ๊ฐ€ ์ •์ƒ์ ์œผ๋กœ ๊ธฐ๋Šฅํ•˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ์ƒ๋ฐ˜์‹ ๊ณผ ๊ฐ€์ŠดํŒ์„ ์—ฝ๋‹ˆ๋‹ค. ํ๊ฐ€ ์ž์œ ๋กญ๊ฒŒ ํŒฝ์ฐฝ๋  ์ˆ˜ ์žˆ์œผ๋ฉฐ ์ผ€์ด๋ธ”์ด ๋ฐฉํ•ดํ•˜๊ณ  ์žˆ์ง€ ์•Š์€์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค.

๋ฌธ์ œ ํ•ด๊ฒฐ

Page 239: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

237

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

โ€ข ํ ์ฃผ๋จธ๋‹ˆ๊ฐ€ ์ ์ ˆํžˆ ์—ฐ๊ฒฐ๋˜์–ด ์žˆ์œผ๋ฉฐ ํŠœ๋ธŒ๊ฐ€ ๋น„ํ‹€์–ด์ ธ ์žˆ์ง€ ์•Š์€์ง€ ์ ๊ฒ€ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ํ ์ฃผ๋จธ๋‹ˆ๊ฐ€ ์ˆ˜ํ‰ ์œ„์น˜๋กœ ์˜ฌ๋ฐ”๋ฅด๊ฒŒ ์‚ฝ์ž…๋˜์–ด ์žˆ๋Š”์ง€ ์ ๊ฒ€ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ํ ์ฃผ๋จธ๋‹ˆ์— ํ ์ง‘์ด๋‚˜ ์ฐข์–ด์ง„ ๋ถ€๋ถ„์ด ์žˆ๋Š”์ง€ ์ ๊ฒ€ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ๊ธฐ๋„ ์•ˆ์— ๊ธฐ๋ฅ˜๋ฅผ ๋ง‰์„ ์ˆ˜ ์žˆ๋Š” ์žฅ์• ๋ฌผ์ด ์—†๋Š”์ง€ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค.

โ€ข ํ ์ˆœ์‘๋„๋ฅผ ์กฐ์ ˆํ•ด๋„ ๋ณ€ํ™”๊ฐ€ ์—†์œผ๋ฉด Laerdal ๊ธฐ์ˆ  ์„œ๋น„์Šค์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

โ€ข ํ ์ €ํ•ญ์— ๋ณ€ํ™”๊ฐ€ ์—†์œผ๋ฉด Laerdal ๊ธฐ์ˆ  ์„œ๋น„์Šค์— ๋ฌธ์˜ํ•˜์‹ญ์‹œ์˜ค.

์ฒญ์ง„ ์‹œ ๊ธฐ๊ณ„์  ์†Œ์Œ

LLEAP ์—์„œ <์ฒญ์ง„ ํฌ์ปค์Šค>๋ฅผ ํด๋ฆญํ•ฉ๋‹ˆ๋‹ค.

๋งฅ๋ฐ•(์š”๊ณจ ๋ฐ ์ƒ์™„)

๋ฌธ์ œ

โ€ข ๋งฅ๋ฐ•์„ ๋Š๋‚„ ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค.

๊ฐ€๋Šฅํ•œ ํ•ด๊ฒฐ์ฑ…

โ€ข ๋งฅ๋ฐ• ์žฅ์น˜ ์œ„๋กœ ํ”ผ๋ถ€๊ฐ€ ๋„ˆ๋ฌด ์กฐ์—ฌ์ ธ ์žˆ์„ ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค. ํ”ผ๋ถ€๋ฅผ ๋‹ค์‹œ ์กฐ์ ˆํ•˜๊ณ  ์žฌ๋ถ€ํŒ…ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ํ˜ˆ์••์ด ์ˆ˜์ถ•๊ธฐ์—์„œ ์ ์–ด๋„ 60์œผ๋กœ ์„ค์ •๋˜๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

โ€ข ์ปดํ”„๋ ˆ์„œ๊ฐ€ ์ผœ์ ธ ์žˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค.

์ฐธ๊ณ : ์š”๊ณจ ๋งฅ๋ฐ•์ด 60 ๋ฏธ๋งŒ์œผ๋กœ ์„ค์ •๋˜์–ด ์žˆ๋Š” ๊ฒฝ์šฐ, ๋ง์ดˆ ๋งฅ๋ฐ•์ด ์‚ฌ๋ผ์งˆ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ •์ง€

๋ฌธ์ œ

โ€ข ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์‘๋‹ต์ด ์—†์Šต๋‹ˆ๋‹ค.

ํ•ด๊ฒฐ์ฑ…

1. Link Box ์ „์›์„ ๋•๋‹ˆ๋‹ค.

2. SimPad๋ฅผ ๋•๋‹ˆ๋‹ค. LLEAP์„ ์‚ฌ์šฉ ์ค‘์ธ ๊ฒฝ์šฐ์—๋Š” ๊ฐ•์‚ฌ PC๋ฅผ ๋•๋‹ˆ๋‹ค.

3. ๋ชจ๋“  ๊ฒƒ์„ ๋‹ค์‹œ ์‹œ์ž‘ํ•ฉ๋‹ˆ๋‹ค.

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๊ฐ€ ์—ฌ์ „ํžˆ ๋ฐ˜์‘ํ•˜์ง€ ์•Š์œผ๋ฉด ๊ท€ํ•˜์˜ Laerdal ๋‹ด๋‹น์ž์—๊ฒŒ ์—ฐ๋ฝํ•˜์‹œ๊ธฐ ๋ฐ”๋ž๋‹ˆ๋‹ค.

๋ฌธ์ œ ํ•ด๊ฒฐ

Page 240: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

238

์ฐธ๊ณ 

Page 241: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

239

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

์ „์ฒด ์น˜์ˆ˜

๊ธธ์ด/ํญ(์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ํ•œํ•จ): 120cm x 42.5cm ๋ฌด๊ฒŒ(์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ์— ํ•œํ•จ): 11.36kg

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์ „์›

์™ธ๋ถ€ ์ „์›: ์ž…๋ ฅ ์ „์•• 9VDC, 1.5A ๋‚ด๋ถ€ ๋ฐฐํ„ฐ๋ฆฌ: 7.4V, 4.4Ah, ๋ฆฌํŠฌ ์ด์˜จ

์Šน์ธ ๋ฐ›์€ SimJunior ์™ธ๋ถ€ ์ „์› ์žฅ์น˜ ๋ฐ ๋ฐฐํ„ฐ๋ฆฌ๋งŒ์„ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

๊ณต๊ธฐ์••

๋‚ด๋ถ€ ๊ณต๊ธฐ ํƒฑํฌ: ์ตœ๋Œ€ 6psi ์™ธ๋ถ€ ๊ณต๊ธฐ ์—ฐ๊ฒฐ: ์ตœ๋Œ€ 16psi

์˜จ๋„ ์ œํ•œ

์ž‘๋™ ์˜จ๋„: +4ยบC ~ 40ยบC ๋ณด๊ด€ ์˜จ๋„: -15ยบ ~ 50ยบC

ํ™˜๊ฒฝ - ์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ๋งŒ ํ•œํ•จ

์ƒ๋Œ€ ์Šต๋„: 20% ~ 90%(๋น„์‘๊ฒฐ) ๋งˆ๋„คํ‚น์ด ์ –์€ ์ƒํƒœ์—์„œ๋Š” ์‹ค์™ธ์—์„œ ์‚ฌ์šฉํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค. ์—ผ์ˆ˜ ๋ถ„๋ฌด ํ…Œ์ŠคํŠธ๋ฅผ ๊ฑฐ์น˜์ง€ ์•Š์•˜์Šต๋‹ˆ๋‹ค.

RF ํ†ต์‹  ์ž‘๋™ ๋ฒ”์œ„: ์ตœ๋Œ€ 10m

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์†Œ์žฌ ๋„ํ‘œ

์˜๋ณต: ๋ฉด, ๋‚˜์ผ๋ก  ํ”ผ๋ถ€ ๋ฐ ๊ธฐ๋„: PVC ์™ธ๋ถ€ ๊ฒฝ์งˆ ํ”Œ๋ผ์Šคํ‹ฑ: PVC, ABS ๋‚ด๋ถ€ ํ”Œ๋ผ์Šคํ‹ฑ: ์‹ค๋ฆฌ์ฝ˜, TPU, PVC, ๋‹ˆํŠธ๋ฆด ABS, POM, ๋‚˜์ผ๋ก  + GF ์—ํญ์‹œ ํด๋ฆฌ์šฐ๋ ˆํƒ„ ๊ธˆ์† ์„ฑ๋ถ„: ์•Œ๋ฃจ๋ฏธ๋Š„, ํ™ฉ๋™, ๊ฐ•์ฒ 

์ปดํ“จํ„ฐ ์ตœ์†Œ ์‚ฌ์–‘

โ€ข Intel i-core 3์„ธ๋Œ€ ์ด์ƒ

โ€ข PassMark - CPU Mark 3,000์  ์ด์ƒ

โ€ข 4GB RAM

โ€ข 120GB ํ•˜๋“œ ๋””์Šคํฌ ๊ณต๊ฐ„

โ€ข 1,366x768 ์ด์ƒ

โ€ข ํ—ค๋“œ์…‹(๋งˆ์ดํฌ ํฌํ•จ)

โ€ข USB ํฌํŠธ โ€“ 2

์ตœ์†Œ ์†Œํ”„ํŠธ์›จ์–ด ์š”๊ตฌ ์‚ฌํ•ญ

โ€ข Windows 7 ๋˜๋Š” Windows 8

โ€ข 100% DPI

์„ธ์ •์•ก

์‹œ๋ฎฌ๋ ˆ์ดํ„ฐ ์„ธ์ฒ™์‹œ์—๋Š” ๋‹ค์Œ ์ค‘ ํ•˜๋‚˜๋ฅผ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

โ€“ 60% ์ด์†Œํ”„๋กœํŒ์˜ฌ ์•Œ์ฝ”์˜ฌ

โ€“ 70% ์—ํƒ„์˜ฌ

โ€“ ์ค‘์„ฑ์„ธ์ œ์™€ ๋ฌผ

IV ์ˆ˜์•ก

IV ๋ฐ IO ์ˆ˜์•ก์„ ํˆฌ์—ฌ์‹œ์—๋Š” ์ฆ๋ฅ˜์ˆ˜ ๋˜๋Š” ํƒˆ์—ผ์ˆ˜๋งŒ ์‚ฌ์šฉํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ํ•˜์‹ญ์‹œ์˜ค.

์‚ฌ์–‘

Page 242: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

240

์ฐธ๊ณ 

Page 243: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

241

์‹œ๋ฎฌ

๋ ˆ์ด

์…˜ ์†Œ

ํ”„ํŠธ

์›จ์–ด

์‹œ๋ฎฌ

๋ ˆ์ด

ํ„ฐ ์„ค

์ •์œ 

์ง€ ๊ด€

๋ฆฌ ์˜ˆ

๋น„ ๋ถ€

ํ’ˆ ๋ฐ

๋ถ€์†

ํ’ˆ์‚ฌ

์–‘๊ฐœ

์š”๋ฌธ

์ œ ํ•ด

๊ฒฐ

์˜ˆ๋น„ ๋ถ€ํ’ˆ ๋ฐ ๋ถ€์†ํ’ˆ

์˜ˆ๋น„ ๋ถ€ํ’ˆ ๋ฐ ๋ถ€์†ํ’ˆ์˜ ์ตœ์‹  ๋ฒ„์ „์€ ๋‹ค์Œ์„ ๋ฐฉ๋ฌธํ•˜์‹ญ์‹œ์˜ค. www.laerdal.com/kr/

์˜ˆ๋น„ ๋ถ€ํ’ˆ ๋ฐ ๋ถ€์†ํ’ˆ

Page 244: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

242

์ฐธ๊ณ 

Page 245: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

243

Page 246: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

244

Page 247: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare
Page 248: SimJunior - Laerdal Medical...SimJunior is a realistic, life-size pediatric patient simulator designed by Laerdal in collaboration with the American Academy of Pediatrics. healthcare

Rev

B

ยฉ 2015 Laerdal Medical AS. All rights reserved. Manufacturer : Laerdal Medical CorporationP.O. Box 38, 226 FM 116, Gatesville, Texas 76528 USAT: +1 (254) 865-7221

Distributed in EU by Laerdal Medical ASP.O. Box 377, Tanke Svilandsgate 30, 4002 Stavanger, NorwayT: (+47) 51 51 17 00

Printed in USA

www.laerdal.com