SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop...

25
SIMATIC S7-1200 FW 4.2 TIA na dosah – září 2016 siemens.cz/micro © Siemens, s.r.o. 2016

Transcript of SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop...

Page 1: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

SIMATIC S7-1200 FW 4.2TIA na dosah – září 2016

siemens.cz/micro© Siemens, s.r.o. 2016

Page 2: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Ondřej Rakušan

DF FA AS

Siemensova 1

155 00 Praha

Mobile: +420 (724) 607 475Phone: +420 (233) 032 470

E-mail:[email protected]

Rakušan Ondřej / DF FA AS

www.siemens.cz

Page 3: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200Novinky: Firmware V4.2 a TIA Portal V14

Nové bezpečnostní CPU:

Hardwarové novinky

Reflection instructions (GetSymbolName,GetSymbolPath, GetInstanceName,GetInstancePath, GetBlockName)

Data block control (CREATE_DB, DELETE_DB,ATTR_DB)

Distributed IO (GETIO, SETIO, GETIO_PART,SETIO_PART, RCVREC, PRVREC, D_ACT_DP)

Diagnostics (Get_Name, GetStationInfo,GetSMCInfo, GetChecksum)

Alarming (Gen_UsrMsg)

Nové programovací instrukce

Watch table

Online backup

Communication – more details

Define user-defined page as start page

Display of copy protection and know-how protection

Web server

Time synchronization

Media Redundancy Protocol (MRP)

S7 routing

PROFIsafe for CPU 121xFC

PROFIenergy

Support 3964R protocol

Komunikace

Online funkce

Backup/restore

Technologické funkce

Gate control

Velikost paměti

unlinked DB: 64kè 256k

CPU1212(F)C: Load memory 2 MB

Save traces to Memory Card (SMC)

CPU 1212FC DC/DC/DCCPU 1212FC DC/DC/Rly

SM 1238 Energy Meter 480 V AC

Ochrana Know how

Copy protect external Load memory

Page 4: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200Novinky: Firmware V4.2 a TIA Portal V14

Novinky SIMATIC S7-1200

Nové moduly• SM1236 AI - Energy Meter• CPU 1212FC DC/DC/DC + DC/DC/RLY

Nové instrukcePřiblížení k S7-1500 (D_ACT_DP, Gen_UsrMsg,…)

Komunikace• MRP at CPU 1215/17 as client• S7-Routing• PROFIsafe

Web server

• Uživatelské stránky jako startovní• Nový vzhled Watch Table• Zobrazení možností CPU• Backup/Restore

Backup/Restore Backup/Restore

09/201609/2016

Page 5: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

• Diagnostická zpráva je vygenerována při dosažení uživatelemdefinované hranice

• Identifikace s využitím LED na CPU• Informace je dostupná v uživatelském programu s využitím instrukce

“GetSMCinfo” block:• Využití paměti SMC (volná + obsazená)• Počet cyklů čtení/zápis

Životnost SIMATIC Memory karty

• Při intenzivním využívání karty (Data Log + Receptury) je zaručenabezpečnost uložených dat a možnost naplánování údržby

Výhody

SIMATIC S7-1200 – Novinky Firmware V4.2Diagnostika a informace o SIMATIC Memory kartě

Seite 5

S7-1500S7-1200NEW NEW

Page 6: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Záloha z Online CPU

STEP 7 Webserver (FW V2.0/4.2) Display (S7-1500 CPU V2.0)

Actual values of all DBs (instance and global DBs) ü ü ü

Software blocks (FCs, FBs, DBs,….) * ü ü ü

PLC variables (variable and constant names) ü ü ü

Hardware configuration ü ü ü

Monitoring tables (Web server) ü ü ü

Actual values of Memory Bits, Timer and Counter ü ü ü

Retentive data ü ü ü

Archives, recipes (PLC) ü ü ü

General data on the SMC (e.g. Help, …) ü ü ü

Backup stored on Project / PC PC Available on SMC

Novinky SIMATIC CPUBackup & Restore

***

PLC in Stop

PLC in Run

F-PLC

* Standard blocks F-PLC S7-1500S7-1200NEW

S7-1500: V13 SP1 / SATS7-1200: V14

NEW

Page 7: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200 – Novinky Firmware V4.2Komunikace – Časová synchronizace S7-1200

Synchronizace času mezi CPU a CP/CM• CPU se chová jako time master• Cyklická synchronizace času CP/CM s CPU• Vzdálené ovládání: CPU získá časovou synchronizaci z CP

Synchronizace času mezi moduly S7-1200

S7-1500S7-1200 ET 200SP

Page 8: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200 – Novinky Firmware V4.2Komunikace – Media redundancy

Založeno na kruhové topologii (IEC 61158-5-10)

Max. 50 bodů v kruhu• PROFINET IO-Controller• PROFINET IO-Devices

200 ms čas na rekonfiguraci

CPU 1215/17 jako MRP klient

Konfigurace a diagnostika v STEP7

Industrial Ethernet

PROFINET

• Bezpečná komunikace!!

S7-1500S7-1200NEW

Page 9: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200 – Novinky Firmware V4.2Komunikace – S7 routing

• Umožňuje komunikaci mezi odlišnými podsítěmi

• SIMATIC S7-1200 se chová jako router

• Založeno na PROFINETU

192.168.0.1 192.168.0.3

177.168.0.1

192.168.0.2

S7 routedConnection

Subn

et1

Subnet 2

Routing mezi CPU a CM/CP, např. pro přenos HMI projektu z ES do panelu

S7-1500S7-1200NEW

Page 10: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200 – Novinky Firmware V4.2Webserver - Watchtable

Nové vlastnosti webového serveru…totožné s SIMATIC S7-1500

S7-1500S7-1200NEW

Page 11: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Ondřej RakušanSales Area ManagerDF FA AS

Siemensova 1

155 00 Praha

Mobile: +420 (724) 607 475Phone: +420 (233) 032 470

E-mail:[email protected]

Rakušan Ondřej / DF FA AS

www.siemens.cz

Děkuji za pozornost

Page 12: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Novinky Simatic S7-1200F

Vojtěch KubáňProduct manager Safety, ET200, SitopDF FA AS

Siemensova 1155 00 Praha 13Tel: 233 032 416E-Mail:[email protected]

DF FA S MP PLC 2

Page 13: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Novinky pro SIMATIC S7-1200CPU 1212FC a PROFIsafe

DF FA S MP PLC 2

Fail-safe SIMATIC S7-1200 CPU’s(DC/DC/DC; DC/DC/Rly) F-DI1215F

§ CPU 1212FC*§ CPU 1214FC§ CPU 1215FC

FW 4.2*§ Všechny F-PLCs podporují

PROFIsafe.Výhody:§ Snadná aktivace bezp. funkcí

pohonů§ Lze ušetřit F-DQ, F-RQ§ Přímé připojení mobilního panelu§ Výměna bezp. dat s jinou 12xxFC

nebo ET200

§ Rychlejší běh bezp. programu

*Vyžaduje Step 7 Safety Basic nebo Advanced V14

Page 14: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Vlastnosti CPU CPU 1211C CPU 1212FC CPU 1214FC CPU 1215FC CPU 1217C

Standard CPU DC/DC/DC, AC/DC/RLY, DC/DC/RLY DC/DC/DC

Failsafe CPU - DC/DC/DC, DC/DC/RLY -

Work Memory, Integrated 50 KB 75 / 100 KB 100 / 125 KB 125 / 150 KB 150 KB

Load Memory, Integrated 1 MB 2 MB 4 MB 4 MB 4 MB

Retentive Memory, Integ. 10 KB 10 KB 10 KB 10 KB 10 KB

Bit Memory (M) 4 KB 4 KB 8 KB 8 KB 8 KB

Integ. Standard Digital I/O 6 Inputs / 4 Outputs 8 Inputs / 6 Outputs 14 Inputs / 10 Outputs 14 Inputs / 10 Outputs 14 Inputs / 10 Outputs*)

Integ. Standard Analog I/O 2 Inputs 2 Inputs / 2 Outputs

Process Image Size 1024 Bytes for Inputs / 1024 Bytes for Outputs

Signal Board Expansion 1 max.

Signal Module Expansion none 2 max. 8 max.

Max. Local I/O – Digital 14 82 284 284 284

Max. Local I/O – Analog 3 19 67 69 69

Nová centrála pro SIMATIC S7-1200CPU 1212FC

Page 15: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

STEP 7 Safety Basic V14…s výhodou využívá vlastností TIA portálu i pro Safety

Rychlý start se Safety§ Jednotné použití – stejný jako

Advanced

§ Struktura F-programu se vytvoříautomaticky po vložení F-CPU

§ Integrovaná, certifikovanáknihovna se všemi běžnými safetyfunkcemi

§ 6ES7833-1FB14-0YA5 179 EUR

+

Zjednodušené ověření§ Globální koncept knihoven pro IO

moduly i funkční bloky včetněsignatury

§ Standardní a průkaznádokumentace bezpečnostníhoprogramu dle normy

+

Výhody§ Využití vlastností TIA Portal je

výhodné i pro safety§ Využití know-how ze STEPU 7

1:1 i pro Safety

+

Efektivita• Centrální Safety Administration

Editor zobrazení a nastavenísafety parametrů

• Test/simulace bezpečnostníchprogramů v S7-PLCSIM

o

+

Rychlý vývoj aplikací§ Využití již vytvořených knihoven

(skládání z hotových komponentvčetně signatur)

§ Programování ve F-FBD a F-LAD

+

Page 16: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1500 Software Controller V14Safety Integrated i pro automatizaci na PC

Nezávislost na Windows +

+

Jednotná konfiguracev TIA PortalNení nutné nic nastavovat ve

Windows

+

Snadná integracePC aplikací

+

Safety IntegratedJeden kontrolér a jedno vývojovéprostředí pro standardní i failsafeaplikaci

+

DF FA S MP PLC 2

Open controllervyužití karet ET200SP včetněsafety

Page 17: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

ET200SP Motor Starter

Hlavní výhody

Kompaktní designJednotná velikost, direkt i reverzační

Snadné zapojeníErgonomická instalace i zapojení

Dostatečný výkonaž do 4 kW ve 3 nastavitelných rozsazích

Snadná integraceIntegrace do ET 200SP, v TIA Portal a v TIASelection Tool, diagnostika

IMAGE

Page 18: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200 – novinky FW V4.2SM1238 Energy Meter 480VAC

SM1238Energy Meter 480VAC

Article Nr.: 6ES7238-5XA32-0XB0

Power supply Vstupy pro měřenínapětí

L1 – L3 directlybez transf: 110V – 480V PH – PH

Vstupy pro měření proudu

L1 – L3 připojený přesproudové trafo;1 nebo 5A

Napěťová trafa U > 480 V

N L1

• Šířka 45 mm• Diag- LED• Podpora sítí TN a TT• Měření el. Veličin 1f 3f• Ukládání hodnot do NV ram

L1 a N přímo připojeny síť

No supply with 24V ofthe CPU

Page 19: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC S7-1200Energy meter

Rozvod:

Princip zapojení

480V

10 KV

Ethernet

Ethernet

*)

*) Current transformer

Energy data

management

+ ..SIMATICPLC S7-1200

SM 1238 Energy Meter

• Napětí

• Proudy

• Fáz. posun

• Výkon – činný, jalový

• Energie

• Frekvence

• Minima a maxima

• Provozní hodiny

• Čítání pulzů

Záznám el. veličin:

Page 20: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

SIMATIC Energy Suite

• Energetický managementPlně integrován do TIA Portal

• Automatiké generováníenergetického programu v PLC

• Analýza spotřeby energií přes webovérozhraní, včetně reportů

S tím souvisí: SIMATIC Energy suite pro TIA Portal V14

Page 21: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Snížení nákladů na energie díky integrovanému energetickému managementu

Co to je

*) Current transformer

• Volitelné rozšíření

• Plně integrované do TIA Portálu

• Licencování dle počtu měřáků

• Funkční bloky pro PLC a Obrazovky proHMI

• Snadné připojení měřáků (Sentron,Simocode, Sinamics, ale i od výrobcůtřetích stran)

• Logování ve WinCC a na MMC

• Reporting

Výhody:

Page 22: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Vzhled Energy Suite

Page 23: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Napájecí zdroj SITOP PSU8600Vlastnosti

Integrovaná Ethernet/Profinet rozhraní-komunikace s ostatními prvky projektu,jako jsou HMI a PLC…

Podpora Energy managementu, ukládáníaktuálních dat a vypínání výstupů

Individuálně konfigurovatelné výstupy, malé rozměry, vysoká účinnost

Integrace v prostředí TIA portalúspora nákladů během návrhu,provozu a údržby

Modulární napájecí zdroj volně rozšířitelný bez nutnosti drátování jednotlivýchčástí …Možnosti připojení buffer modulů pro překlenutí krátkodobých výpadků napájení

…napájecí zdroj SITOP PSU8600 je nedílnou součástí vývojového prostředí TIA Portal

Kompletní monitoring

a diagnostika během provozu či preventivníkontroly

Page 24: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Power Supply System SITOP PSU86002015 – nové vlastnosti a rozšiřující moduly

System modulesCNX8600 BUF8600

max. 4 max. 2

Basic unitPSU8600, 3-ph.

1 Output 4 Outputs

4 Outputs,4 x 5 A

100 msat 40 A

4 Outputs,4 x 10 A

300 msat 40 A

24 V DC/40 A, 4 x 10 A

Nové vlastnosti napájecího systému PSU8600:§ Až 4 rozšiřující moduly = 20 outputs§ Nastavitelné výstupní napětí 5 až 28 V DC§ Web-Server-enabling switch na base unit§ Signalizace shut down IPC v případě výpadku napájení (max. 20 s při 40 A, tedy při 800s při odběru 1A)

24 V DC/20 A, 4 x 5 A

NEW

24 V DC/40 A

NEW

NEW

24 V DC/20 A

10 sat 40 A

NEW

4 sat 40 A

NEW

Page 25: SIMATIC S7-1200 FW 4 - Siemens · PDF fileSIMATIC S7-1200 FW 4.2 TIA na dosah ... PLC in Stop PLC in Run F-PLC * Standard blocks F-PLC S7-1200 S7-1500 NEW ... • Pln ě integrované

© Siemens, s.r.o. 2016

Děkuji za pozornost!

Vojtěch KubáňProduct manager Safety, ET200, SitopDF FA AS

Siemensova 1155 00 Praha 13Tel: 233 032 416E-Mail:[email protected]