Siemens Acuson 3D TEEBruce Bollen, MD
Missoula AnesthesiologyInternational Heart Institute of Montana
Missoula, Montana
![Page 2: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/2.jpg)
Dr. Bollen 2015
SCA Echo WeekMarch 23-27, 2015
Atlanta, GA
![Page 3: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/3.jpg)
Dr. Bollen 2015
Siemens Matrix Array TEE probe
Over 2,000 piezo crystals in transducer
Allows simultaneous biplane imaging
Designed for acquisition of 3D matrix volumes
Probe programmable for preferred views
Designed to minimize thermal issues
![Page 4: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/4.jpg)
Dr. Bollen 2015
Siemens 4D Matrix Volume Analysis
Siemens Acuson 3D allows 4D volume analysis Allows for 4D Volume Review using
multiplane reconstruction of 3D volume sets into 2D cropped planes– D’art 3D volume viewing
– Slice (multislice capabilities) of 3D volumereview using 2D cropped planes
– Allows orientation of image in cropped plane by rotation, up, down.
![Page 5: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/5.jpg)
Dr. Bollen 2015
MV 4D Volume Assessment
![Page 6: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/6.jpg)
Dr. Bollen 2015
AV (Root) 4D Volume Assessment
![Page 7: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/7.jpg)
Dr. Bollen 2015
Siemens 3D volume eSie Valve Programs
Utilizes eSie Valve analysis programs to simplify valve analysis– Mitral
• Multiplane cropping• PISA assessment• MV modeling
– Aortic • Multiplane cropping• AV (Root) modeling
– Aortic – Mitral• Combines MV and Aortic models.
![Page 8: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/8.jpg)
Dr. Bollen 2015
eSie Valve- Mitral Valve
Utilizes eSie Valve keys to set up MV orientation for anlaysis
4 boxes of echo: 3 2D cropped planes and 4th of 3D image/model
![Page 9: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/9.jpg)
Dr. Bollen 2015
Beginning of eSie Valve Mitral
![Page 10: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/10.jpg)
Dr. Bollen 2015
eSie Valve- mitral opened
![Page 11: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/11.jpg)
Dr. Bollen 2015
eSie valve MV modeling
Siemens eSie valve allows MV modeling with various ways to view
![Page 12: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/12.jpg)
Dr. Bollen 2015
Siemens eSie Valve MV Modeling
![Page 13: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/13.jpg)
Dr. Bollen 2015
Siemens eSie Valve MV Modeling
![Page 14: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/14.jpg)
Dr. Bollen 2015
Siemens eSie Valve MV Modeling
![Page 15: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/15.jpg)
Dr. Bollen 2015
Siemens eSie Valve MV Modeling -Analysis
![Page 16: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/16.jpg)
Dr. Bollen 2015
Siemens eSie Valve Aortic Valve
![Page 17: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/17.jpg)
Dr. Bollen 2015
Siemens eSie Valve Aortic Valve (Root)
![Page 18: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/18.jpg)
Dr. Bollen 2015
Siemens eSie Valve Aortic Valve -Modeling
![Page 19: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/19.jpg)
Dr. Bollen 2015
Siemens eSie Valve Aortic Valve Modeling
![Page 20: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/20.jpg)
Dr. Bollen 2015
Siemens eSie Valve AV Modeling Analysis Analysis - Surgical
![Page 21: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/21.jpg)
Dr. Bollen 2015
Siemens eSie Valve AV Modeling Analysis Analysis - Diagnosis
![Page 22: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/22.jpg)
Dr. Bollen 2015
Siemens eSie Valve AV Modeling Analysis Analysis - Intervention
![Page 23: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/23.jpg)
Dr. Bollen 2015
Siemens combined AV-MV Modeling
Siemens has developed a combined AV-MV modeling system
Potential to look at AV-MV interactions
Frame Rate resolution will be one diagnostic concern
![Page 24: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/24.jpg)
Dr. Bollen 2015
Siemens Combined AV-MV Modeling
![Page 25: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/25.jpg)
Dr. Bollen 2015
Siemens LV and RV Modeling
Siemens Also has LV and RV modeling programs with their 4D analysis
![Page 26: Siemens Acuson 3D TEE Bruce Bollen, MD Missoula Anesthesiology International Heart Institute of Montana Missoula, Montana.](https://reader037.fdocuments.net/reader037/viewer/2022110103/5697c0141a28abf838ccd628/html5/thumbnails/26.jpg)
Dr. Bollen 2015
Post Procedure Analysis Singo Dynamics- Siemens overall imaging
storage system for CT, MRI, Cath, and echo Utilizes advanced E2 applications for CT, MRI Can utilizes eSie Applications Ultrasound Workstation- For those hospitals
with Siemens echo machine, but without Singo Dynamics system.
Ultrasound Workstation utilizes eSie Applications.