Shrinkage Properties of Kenaf Bio Fibrous Concrete ......Compacting Factor Test (BS 1881-103: 1993)...

16
Shrinkage Properties of Kenaf Bio Fibrous Concrete Composite for Sustainable Construction 1* Ogunbode, E. B . , 2 Kure M. A., 1 Alao, T. O., 2 Mohoro, I. S. & 2 Adamu, B. 1 Department of Building, Federal University of Technology, Minna-Nigeria 2 Department of Building Technology, Niger State Polytechnic, Zungeru-Nigeria [email protected] Keywords: , K

Transcript of Shrinkage Properties of Kenaf Bio Fibrous Concrete ......Compacting Factor Test (BS 1881-103: 1993)...

  • Shrinkage Properties of Kenaf Bio Fibrous Concrete Composite for Sustainable

    Construction

    1*Ogunbode, E. B., 2Kure M. A., 1Alao, T. O., 2Mohoro, I. S. & 2Adamu, B.

    1Department of Building, Federal University of Technology, Minna-Nigeria 2Department of Building Technology, Niger State Polytechnic, Zungeru-Nigeria

    [email protected]

    Keywords: , K

    mailto:[email protected]

  • Materials and Methods Materials and Mix Proportion

  • Table 1: Details of Kenaf Fibre (KF)

    Natural fibre Length (mm) 25, 50 and 75

    65.4 Density (kg/m3) 1200 Tensile Strength (N/mm2) 135-930

    Cellulose (%) 31-57 Hemicelluloses (%) 21-23 Lignin (%) 4.79-19.0 Pectin (%)

    Table 2

    Mix type KF length (lf) (mm)

    KF volume (Vf) (%)

    Cement (Kg/m3)

    CA (Kg/m3)

    FA (Kg/m3)

    Water (Kg/m3)

    KF volume fraction (Vf) (Kg/m3)

    KBFCC 1A

    KBFCC 2A KBFCC 3A KBFCC 4A KBFCC 5A KBFCC 6A KBFCC 1B

    KBFCC 2B KBFCC 3B KBFCC 4B

    KBFCC 5B KBFCC 6B KBFCC 1C

    KBFCC 2C KBFCC 3C KBFCC 4C KBFCC 5C KBFCC 6C

    KF Kenaf Fibre, FA- Fine Aggregate, CA Coarse Aggregate

  • Concrete Testing Fresh Concrete Properties Test

    Slump Test (ASTM C143/C143M, 2017)

    Vebe Test (BS EN, 12350-3: 2009)

    (a) (b) (c)

    Figure 2 An operational procedures for slump test: (a) Abrams slump apparatus, (b and c) Measurement of slump

  • (a) Set up for Vebe test (b) VB apparatus in operation

    Figure 3 Operational procedures for Vebe test Compacting Factor Test (BS 1881-103: 1993)

    Shrinkage Test

    weight of partially compacted concreteCFweight of fully compacted concrete (1)

  • Figure 4 Operational procedures for compacting factor test

    16

    1 0

    )0(

    161

    i l

    lilsh (2)

    Where:

    sh Shrinkage strain (length change of the specimens at any age)

    il Measured distance between ith pair of gage points

    0l Original distance between ith pair of gage points measured immediately after demoulding.

  • Figure 5 An operational sequence for Shrinkage test

    Results and Discussion Concrete

  • Shrinkage KBFCC

  • Figure 9: Influence of 25 mm Fibre length and age of exposure on the free drying Shrinkage of concrete

    Figure 10: Influence of 50 mm Fibre length and age of exposure on the free drying Shrinkage of concrete

    Figure 11: Influence of fibre addition 75 mm Fibre length and age of exposure on the free drying Shrinkage of

    concrete *Vf = Volume of kenaf fibre, to = exposure age of specimen to shrinkage testing

  • Conclusions

    References

  • Verlag Berlin Heidelberg