Shot Noise and conductance spectroscopy on a single molecule junction Oren Tal Michael Krieger, Rik...

17
Shot Noise and conductance spectroscopy on a single molecule junction Oren Tal Michael Krieger, Rik Hortensius, Bas Leerink Robert Thijssen, Darko Djukic and Jan van Ruitenbeek Leiden University,Netherlands Capri Spring

Transcript of Shot Noise and conductance spectroscopy on a single molecule junction Oren Tal Michael Krieger, Rik...

Shot Noise and conductance spectroscopy on a single molecule junction

Oren TalMichael Krieger, Rik Hortensius, Bas Leerink

Robert Thijssen, Darko Djukic and Jan van Ruitenbeek

Leiden University,Netherlands

Capri Spring School 2007

Electron-Vibration Interaction

-80 -60 -40 -20 0 20 40 60 80-0.2

0.0

0.96

0.98

1.00

d2 I/dV

2 (ar

b. u

nits

)

d

I/dV

(G0)

Bias voltage (mV)

Inelastic Electron Tunneling SpectroscopyTypically low conductance ~10-5G0

Djukic et al. Phys. Rev. B (R). 71 (2005), 161402Thygesen et al. Phys. Rev. Lett. 94 (2005), 036807

Point Contact SpectroscopyTypically high conductance ~1G0

C2H2

Stipe et al. Rev. Sci. Inst.70 (1999), 137

H2

heGo 22

-60 -40 -20 0 20 40 600.97

0.98

0.99

dI/d

V [G

0]

Bias Voltage [mV]

Pt+H2O

Conductance curves of different molecular junctions

-60-40-20 0 20 40 600.22

0.24

0.26

0.28

dI/d

V [G

0]

Bias Voltage [mV]

Pt+H2O

-80 -40 0 40 800.30

0.32

0.34

0.36

0.38

0.40

dI/d

V [G

0]

Bias Voltage [mV]

Ag+O2

-60 -40 -20 0 20 40 600.92

0.94

0.96

0.98

1.00

dI/

dV [G

0]

Bias Voltage [mV]

Pt+H2

Step up

Step down

heGo 22

“step up” to “step down” shape transition as a function of conductance

-60 -40 -20 0 20 40 600.45

0.50

0.55

0.60

0.65

0.70Pt+H2O

dI/d

V [G

0]

Bias Voltage [mV]

Step size and direction in conductance curves

-60 -40 -20 0 20 40 600.45

0.50

0.55

0.60

0.65

0.70

dI/

dV

[G0]

-60-40-20 0 20 40 600.22

0.24

0.26

0.28

Bias Voltage [mV]

-60 -30 0 30 600.97

0.98

0.99

L. de la Vega, A. Martín-Rodero, N. Agraït, and A. Levy Yeyati, PRB 73, 075428 (2006)

Low Transmission

5.0

HighTransmission

5.0

(M. Paulsson et al. PRB 72, 201101R (2005) similar 0.5 transition)

Deviation from a single channel model

Single channel model:transition between “step up” to “step down”at 5.0

Do we have more then a single transmission channel for a Pt-H2O -Pt junction?

Shot Noise measurements

In our experiment:transition between “step up” to “step down”at GoG 65.0

i ih

eG

22

i i

i iiI eIS

)1(

2

i ih

eG

22

Shot noise in point contacts

τ1

τi

Shot noise in Pt+H2O single molecule junction

6

The transition between to occurs above 5.0 5.0 GoG 01.052.0

0.0 0.1 0.2 0.3 0.4 0.50

1

2

3

4

Fullshotnoise 1=0.48

2=0.04

Exc

ess

nois

e [1

0-2

6 A

2/H

z]

Bias Current [A]

GoG 01.052.0

0.0 0.2 0.4 0.6 0.80

1

2

3

4

1=0.95

2=0.05

Fullshotnoise

Exc

ess

nois

e [1

0-26

A2 /

Hz]

Bias Current [A]

GoG 01.000.1

At the main transmission channel has 5.0GoG 01.052.0

Conclusions

Point contact spectroscopy : The effect of electron - vibration interactions on the differential conductanceis inverted at a certain conductance. Shot noise measurements: More than a single transmission channel through the Pt-H2O-Pt junction

Using the combination of point contact spectroscopy and shot noisemeasurements the apparent deviation from the relevant models could beresolved.

Open question: what is the role of transmission channel mixing due to electron – vibration interactions?

Acknowledgments

Prof. Jan van Ruitenbeek

Michael KriegerRik HortensiusBas Leerink Robert ThijssenDarko DjukicChristian Martin Sander Otte

Ruud van EgmondBert Crama

Electron-Phonon Interaction

V

dI/dV

0V

Point Contact SpectroscopyTypically high transmission probability

V

dI/dV

0V

Inelastic Electron Tunneling SpectroscopyTypically low transmission probability

LeV

R

R

E

11

k

E

eV

e

e

i i

i iiI eIS

)1(

2

i ih

eG

22

Shot noise in point contacts

5 10 15 20

4x10-18

6x10-18

8x10-1810-17

0.8A

G=1.00+/-0.01G0

Tot

al n

oise

[V2 /

Hz]

Frequency [KHz]

0A

Lock-in

I-V

Spectrum Analyser

100100

1000 1000

100MFaraday cage

dipstick

PC

cryostat

battery

S1

S2

0.0 0.2 0.4 0.6 0.80

1

2

3

4

1=0.95

2=0.05F=0.095

Fullshotnoise

Exc

ess

nois

e [1

0-26

A2 /

Hz]

Bias Current [A]

Shot noise in Pt+H2O single molecule junction

6

0.0 0.1 0.2 0.3 0.4 0.50

1

2

3

4

Fullshotnoise 1=0.48

2=0.04F=0.554

G = 0.52 +/-0.01G0

Exc

ess

nois

e [1

0-2

6 A

2/H

z]

Bias Current [A]

At about G=0.5G0 the main transmission channel has 5.0

The transition between to occurs above 5.0 5.0 GoG 01.052.0

GoG 01.052.0 GoG 01.000.1

“ Elastic” and inelastic contributions

6

J. K. Viljan et al. PRB 72, 245415 (2005)

0 2 4 60

1000

2000

3000

Vb=0.1V

nu

mb

er

of c

ou

nts

Conductance (G0)

Pt

Conductance histograms: Pt

8 10 12 14 16 180

1

2

3

4

5

Co

nd

uct

an

ce (G

0)

Piezo voltage (V)

Pt

Conductance histograms: Pt+H2O

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00

500

1000

1500

2000

2500

30000.96G0 Vb=0.2V

1.16G0

Pt + H2O

No

. o

f co

un

ts

Conductance [G0]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.00

500

1000

1500

2000

2500

3000

1.00G0

0.20G0

Vb=0.1V

0.60G0

Pt + H2O

No

. o

f co

un

ts

Conductance [G0]

>at lower bias voltages lower peaksare more pronounced.

Conductance traces

0.30

1

2

3

4

C

on

du

cta

nce

(G0)

Piezo voltage (V)

Pt+H2O

0.2 0.30

1

2

3

4

Co

nd

uct

an

ce (G

0)

Piezo voltage (V)

Pt+H2O

0.2 0.3 0.40

1

2

3

4

Co

nd

uct

an

ce (G

0)

Piezo voltage (V)

Pt+H2O

0.2 0.30

1

2

3

4

Co

nd

uct

an

ce (G

0)

Piezo voltage (V)

Pt+H2O

>Pt-H2O-Pt configurations with higher conductance then 1G0 (?)