SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision...

23
F.E.C. EL: 100'-0" A 1 . 01 3 4 1 2 A101 1 A101 101 000 1 ROOM 202A 150 SF A A ENLARGED PLAN / DETAIL IDENTIFICATION SECTION IDENTIFICATION INTERIOR ELEVATION IDENTIFICATION DIMENSION TO CENTERLINE DIMENSION LINE EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED NEW CONSTRUCTION CENTERLINE DOOR NUMBER WINDOW NUMBER PARTITION TYPE Room Name ELEVATION MARKER SPOT ELEVATION ROOF PITCH KEYED NOTE EXTERIOR ELEVATION IDENTIFICATION FURNITURE TAG NORTH ARROW DRAWING REVISION / REVISION NUMBER A101 1 SHEET NUMBER COLUMN GRID TAG ACCESSIBLE ELEMENT CLEAR FLOOR SPACES FOR WHEELCHAIR: 2'-6" x 4'-0" AND 5'-0" DIAMETER DIRECTION OF DOWNWARD SLOPE STAIR TAG ROOM FINISH TAG 3' - 0" 3' - 0" WALL CEILING BASE FLOOR SEMI RECESSED FIRE EXTINGUISHER 12 6.0 1 N R @ 7 1/2" 20 XX XX WALL CEILING WALL FINISH TAG FINISH TRANSITION TAG 0 Detail Number Sheet Number Detail Number Sheet Number Elevation Number Sheet Number Sheet Number Sequence Sheet Type Discipline Elevation Number Sheet Number Room Number Room Area (If Displayed) ROOM TAG C L ACOUSTICAL TILE ALUMINUM CARPET DISTURBED EARTH UNDIST. EARTH EIFS GLASS ELEVATION GLASS SECTION GYPSUM BOARD HOMOSOTE INSULATION - RIGID GRAVEL MASONRY - CONC. BLOCK PLYWOOD SAND SHINGLE STEEL STONE WOOD drawing prepared by drawing title description date mark R E V I S I O N S IMPROVEMENTS TO 40 SHORE ROAD BI-NN-665 WATERFORD, CONNECTICUT 14052 AEA PROJECT No. STATE OF CONNECTICUT DEPARTMENT OF CONSTRUCTION SERVICES DIVISION OF CONSTRUCTION SERVICES AMENTA|EMMA ARCHITECTS, P.C. 242 TRUMBULL STREET HARTFORD CT, 06103 6.27.2014 SD SUBMISSION project CAD no. project no. date scale drawn by approved by drawing no. P:\14052.rvt 12.17.2014 DD SUBMISSION 7.14.2017 FOR BIDDING JULY 14, 2017 As indicated GENERAL NOTES, SYMBOLS, GRAPHICS LEGEND G1.00 AF CB 19 FOR THE EXECUTION OF THE WORK TO BE PERFORMED UNDER THIS CONTRACT AND FOR THE MANUFACTURE OR TRANSPORTATION OF ANY OF THE MATERIALS OR EQUIPMENT TO BE USED OR INSTALLED, THE CONTRACTOR SHALL EMPLOY ONLY SUCH LABOR THROUGHOUT AS WILL NOT INTERFERE WITH THE SPEEDY AND UNINTERRUPTED COMPLETION OF THE PROJECT. ALL WORK SHALL BE DONE BY MECHANICS SKILLED IN THEIR TRADE AND SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH THE BEST TRADE PRACTICES. 20 ANY MATERIALS DELIVERED OR WORK PERFORMED, CONTRARY TO THE DRAWINGS AND SPECIFICATIONS AND APPROVED SHOP DRAWINGS, SHALL BE REMOVED BY THE CONTRACTOR AT HIS OWN EXPENSE, AND THE SAME SHALL BE REPLACED WITH OTHER MATERIALS OR WORK SATISFACTORY TO THE ARCHITECT. THE CONTRACTOR SHALL ALSO ASSUME THE COST OF REPLACING THE WORK WHICH MAY BE DISTURBED. 21 THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY AND ACCURATELY LAYING OUT THE WORK AND FOR THE LINES AND MEASUREMENTS HEREIN. HE SHALL ESTABLISH NECESSARY REFERENCE LINES AND PERMANENT BENCH MARKS FROM WHICH BUILDING LINES AND ELEVATIONS SHALL BE TAKEN. ELEVATION HEIGHTS OF ALL WORK INCLUDING BUT NOT LIMITED TO SOFFITS, CEILINGS, DOORS, HOLLOW METAL SHALL BE TRUE AND LEVEL WITHIN A MAXIMUM TOLERANCE OF 1/8" OVERALL THE ENTIRE PROJECT. 22 FOR ALL PARTITIONS REFER TO PARTITION SYMBOLS ON DRAWINGS AND THE PARTITION TYPE DETAILS WHICH SHOWS PARTITION CORES AND FINISHES. 23 A. THE PREMISES AND THE JOB SITE SHALL BE MAINTAINED IN A REASONABLY NEAT AND ORDERLY CONDITION AND KEPT FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND RUBBISH DURING THE ENTIRE CONSTRUCTION PERIOD. REMOVE CRATES, CARTONS AND OTHER FLAMMABLE WASTE MATERIALS OR TRASH FROM THE WORK AREAS AT THE END OF EACH WORKING DAY. B. ELECTRICAL CLOSETS, PIPE AND DUCT SHAFTS, CHASES, FURRED SPACES AND SIMILAR SPACES WHICH ARE GENERALLY UNFINISHED SHALL BE CLEANED AND LEFT FREE FROM RUBBISH, LOOSE PLASTER, MORTAR DRIPPINGS, EXTRANEOUS CONSTRUCTION MATERIALS, DIRT AND DUST. C. CARE SHALL BE TAKEN BY WORKMEN NOT TO MARK, SOIL, OR OTHERWISE DEFACE FINISHED SURFACES. IN THE EVENT THAT FINISHED SURFACES BECOME DEFACED, THE CONTRACTOR IS RESPONSIBLE FOR CLEANING AND RESTORING SUCH SURFACES TO THEIR ORIGINAL CONDITION. IF THIS IS NOT POSSIBLE, DAMAGED SURFACES SHALL BE REPLACED. D. CLEAN UP IMMEDIATELY UPON COMPLETION OF EACH TRADE'S WORK. E. CLEAN AREAS OF THE BUILDING IN WHICH PAINTING AND FINISHING WORK IS TO BE PERFORMED JUST PRIOR TO THE START OF THIS WORK, AND MAINTAIN THESE AREAS IN SATISFACTORY CONDITION FOR PAINTING AND FINISHING. F. THIS CLEANING INCLUDES THE REMOVAL OF TRASH AND RUBBISH FROM THESE AREAS, BROOM CLEANING OF FLOORS, THE REMOVAL OF ANY PLASTER, MORTAR, DUST AND OTHER EXTRANEOUS MATERIALS FROM FINISH SURFACES, INCLUDING BUT NOT LIMITED TO, MISCELLANEOUS METAL, WOODWORK, PLASTER, GYPSUM DRYWALL, MASONRY, CONCRETE, MECHANICAL AND ELECTRICAL EQUIPMENT, PIPING, DUCTWORK, CONDUIT, AND SURFACES VISIBLE AFTER GRILLES, REGISTERS AND OTHER SUCH FIXTURES OR DEVICES ARE IN PLACE. G. IN ADDITION TO THE CLEANING SPECIFIED ABOVE AND THE MORE SPECIFIC CLEANING WHICH MAY BE REQUIRED IN VARIOUS SECTIONS OF THE SPECIFICATIONS, THE PREMISES SHALL BE PREPARED FOR OCCUPANCY BY: (i)A THOROUGH CLEANING THROUGHOUT INCLUDING WASHING OR CLEANING BY OTHER APPROVED METHODS OF ALL FLOORS AND SURFACES ON WHICH DIRT OR DUST HAS COLLECTED AND BY WASHING GLASS, REMOVING ALL PAINT, PUTTY AND STAINS THEREFROM. (ii)PROVIDING AND MAINTAINING PROTECTION OF EXISTING AND INSTALLED PORTIONS OF THE WORK. (iii)LEAVING ALL FIXTURES AND EQUIPMENT IN AN UNDAMAGED, BRIGHT, CLEAN, POLISHED CONDITION. (iv)CLEAN AND POLISH ALL HARDWARE, AND OTHER METAL WORK. (v)FOR FINAL CLEANING, CONTRACTOR SHALL ENGAGE THE SERVICES OF A PROFESSIONAL CLEANING COMPANY TO ACCOMPLISH THE FOLLOWING: REMOVAL OF PUTTY STAINS AND PAINT SPOTS, WASHING AND POLISHING OF GLASS, CLEANING AND POLISHING OF ALL EXPOSED FINISH HARDWARE, AND A THOROUGH CLEANING OF ALL SURFACES; RESILIENT TILE / SHEET VINYL FLOORING POLISHED & BUFFED 24 THE CONTRACTOR SHALL KEEP THE ARCHITECT INFORMED OF THE PROGRESS OF HIS WORK. NO WORK SHALL BE CLOSED OR COVERED UNTIL IT HAS BEEN DULY INSPECTED AND APPROVED. SHOULD UNINSPECTED WORK BE COVERED, THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, UNCOVER ALL SUCH WORK SO THAT IT CAN BE PROPERLY INSPECTED AND AFTER SUCH INSPECTION, HE SHALL PROPERLY REPAIR AND REPLACE ALL WORK INTERFERED WITH. 25 THE WORK IS SUBJECT TO INSPECTION BY THE ARCHITECT AND ACCEPTANCE BY THE OWNER. 26 PROTECT OWNER'S PROPERTY, EQUIPMENT AND EMPLOYEES FROM INJURY AND DAMAGE. 27 ALL HVAC, PLUMBING, SPRINKLER AND ELECTRICAL LINES ARE TO BE COORDINATED SO THAT NO CONFLICTS OCCUR. ANY CONFLICTS WHICH RESULT IN A RELOCATION OF A FINISHED SURFACE MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. 28 CONTRACTOR SHALL CONSULT WITH ELECTRICAL AND PLUMBING SUB-CONTRACTORS FOR LOCATIONS OF CONDUIT AND PIPES IN FOUNDATION, SLABS ON GRADE, AND EXTERIOR WALLS AND SHALL INSTALL WATERTIGHT PIPE SLEEVES AT THEIR RESPECTIVE LOCATIONS. 29 A SET OF THE INSTRUCTION MANUALS AND INSTALLATION INSTRUCTIONS OF ALL EQUIPMENT AND ACCESSORIES INSTALLED IN THIS JOB SHALL BE KEPT BY THE CONTRACTOR AND TURNED OVER TO THE OWNER AT THE COMPLETION OF THE JOB. IN ADDITION, AS-BUILT DRAWINGS OF THE COMPLETED WORK ARE TO BE COMPLETED, SIGNED AND SEALED, AND DELIVERED TO THE ARCHITECT AND OWNER AT THE COMPLETION OF THE JOB. 30 PROVIDE ADEQUATE BACKUP AND BLOCKING FOR ALL WALL OR CEILING MOUNTED EQUIPMENT, ARCHITECTURAL WOODWORK, HANDRAILS, LIGHTING OR OTHER MISCELLANEOUS ITEMS AS SHOWN ON DRAWINGS TO ASSURE A SECURE INSTALLATION. 31 SUBMITTALS THAT REQUIRE THE REVIEW OF THE ARCHITECT/ENGINEERING TEAM SHALL BE DELIVERED IN DIGITAL FORMAT, AND IF REQUIRED BY THE ARCHITECTURE/ENGINEERING TEAM, BE SUBMITTED AS HARDCOPY AS WELL. A SEVEN (7) BUSINESS DAY PERIOD OF TIME WILL BE ALOTTED FOR ARCHITECT'S/ENGINEER'S REVIEW OF THE CONSTRUCTION SUBMITTAL, AND IT CANNOT BE GUARANTEED THAT AN EXPEDITED SCHEDULE CAN BE ACCOMMODATED. 32 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING OR OBTAINING SHOP DRAWINGS FROM THE SUBCONTRACTORS AND MANUFACTURERS. THE APPROVAL AND SUBMITTAL OR SHOP DRAWINGS TO THE ARCHITECT REPRESENTS THAT THE CONTRACTOR HAS REVIEWED AND VERIFIED THE USE OF APPROPRIATE MATERIALS, PROPER FIELD MEASUREMENTS, FIELD CONSTRUCTION REQUIREMENTS, AND HAVE COORDINATED THE INFORMATION CONTAINED IN THE SUBMITTAL. DEVIATIONS FROM THE CONTRACT DOCUMENTS MUST BE CALLED TO THE ATTENTION OF THE ARCHITECT IN WRITING AND REQUIRES SPECIFIC APPROVAL OF THE ARCHITECT. ARCHITECTURAL APPROVAL OF THE SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF ERRORS OR OMISSIONS, PER AIA DOCUMENT A201-2007 STANDARDS. 33 ALL QUESTIONS TO THE ARCHITECT/ENGINEERING TEAM SHALL BE SUBMITTED AS REQUEST'S FOR INFORMATION (RFI'S), WITH THE CONSTRUCTION MANAGER'S LETTERHEAD. THE CONSTRUCTION MANAGER WILL PROVIDE A NUMBER TO THE RFI. A ONE (1) WEEK PERIOD OF TIME WILL BE ALOTTED FOR ARCHITECTURAL/ENGINEERING REVIEW OF THE RFI. ALL CORRESPONDENCE REGARDING RFI'S WILL BE FROM THE CONSTRUCTION MANAGER TO THE ARCHITECT. THE ARCHITECT WILL DISSEMINATE THE INFORMATION TO THE APPROPRIATE ENGINEER'S IF REQUIRED. NO SUB-CONTRACTOR IS TO CONTACT THE ARCHITECT OR ENGINEER WITH A QUESTION DIRECTLY; ALL QUESTIONS TO THE ARCHITECTURE/ENGINEERING TEAM SHALL BE SENT THROUGH THE CONSTRUCTION MANAGER. 1 THE TERM CONTRACTOR IS USED IN THESE NOTES TO IDENTIFY THE PARTY WHO IS CONTRACTED TO THE OWNER AND WHO CAUSES THE WORK OF THE CONTRACT TO BE PERFORMED EITHER BY HIS OWN FORCES OR BY OTHER CONTRACTORS RETAINED BY HIM. 2 THE CONTRACTOR SHALL DO THIS WORK IN ACCORDANCE WITH LOCAL LAWS AND ORDINANCES HAVING JURISDICTION. OTHER THAN THE BULDING PERMIT, THE CONTRACTOR SHALL OBTAIN ALL OTHER PERMITS AND APPROVALS AS REQUIRED BY LAW FOR THE COMPLETION OF THE WORK AND ISSUANCE OF A FULL CERTIFICATE OF OCCUPANCY. 3 THE SUBMISSION OF A PROPOSAL BY THE CONTRACTOR WILL BE CONSTRUED AS EVIDENCE THAT A CAREFUL AND THOROUGH EXAMINATION OF THE SITE HAS BEEN MADE AND LATER CLAIMS FOR LABOR, MATERIALS OR EQUIPMENT REQUIRED OR FOR DIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED. IT SHALL ALSO CONSTITUTE A REPRESENTATION THAT THE CONTRACTOR HAS CHECKED AND VERIFIED ALL QUANTITIES, WORK AND MATERIALS INVOLVED AND THAT HE SHALL TAKE RESPONSIBILITY FOR ANY DEFICIENCIES THEREIN. 4 BEFORE ORDERING ANY MATERIAL OR DOING ANY WORK, EACH TRADE SHALL VERIFY ALL MEASUREMENTS IN THE FIELD AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED ON ACCOUNT OF DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THE MEASUREMENTS INDICATED ON THE DRAWINGS; ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE ARCHITECT FOR CONSIDERATION AND CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 5 ALL OF THE ARCHITECT'S DRAWINGS AND CONSTRUCTION NOTES ARE COMPLIMENTARY AND WHAT IS CALLED FOR BY EITHER WILL BE BINDING AS IF CALLED FOR BY ALL: ANY WORK SHOWN OR REFERRED TO ON ANY ONE DRAWING SHALL BE PROVIDED AS THOUGH SHOWN ON ALL DRAWINGS. WHENEVER AN ITEM IS SPECIFIED AND/OR SHOWN ON THE DRAWINGS BY DETAIL OR REFERENCE IT SHALL BE CONSIDERED TYPICAL FOR OTHER ITEMS WHICH ARE OBVIOUSLY INTENDED TO BE THE SAME EVEN THOUGH NOT SO DESIGNATED OR SPECIFICALLY NAMED BUT DO SERVE THE SAME FUNCTION. 6 THE WORK TO BE PERFORMED CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT, TOOLS, TRANSPORTATION, SUPPLIES, FEES, MATERIALS, AND SERVICES IN ACCORDANCE WITH THESE NOTES AND DRAWINGS AND PERFORMING ALL OPERATIONS NECESSARY TO CONSTRUCT AND INSTALL COMPLETE AND IN SATISFACTORY CONDITION THE VARIOUS MATERIALS AND EQUIPMENT AT THE LOCATIONS SHOWN. IT IS INTENDED THAT THE DRAWINGS INCLUDE EVERYTHING REQUISITE AND NECESSARY TO FINISH THE ENTIRE WORK PROPERLY, NOTWITHSTANDING THE FACT THAT EVERY ITEM NECESSARILY INVOLVED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. ANY ITEM WHICH MAY BE REASONABLY CONSTRUED AS INCIDENTAL TO THE PROPER AND SATISFACTORY COMPLETION OF THE WORK IN ACCORDANCE WITH THE INTENT OF THESE NOTES AND DRAWINGS IS HEREBY INCLUDED. 7 THE CONTRACTOR SHALL ABIDE BY AND COMPLY WITH THE TRUE INTENT AND MEANING OF THE DRAWINGS AND NOTES TAKEN AS A WHOLE AND SHALL NOT AVAIL HIMSELF OF ANY OBVIOUS ERRORS OR OMISSIONS, SHOULD ANY EXIST. SHOULD ANY ERROR OR DISCREPANCY APPEAR OR ANY DOUBT ARISE AS TO THE TRUE MEANING OF THE DRAWINGS OR NOTES, THE CONTRACTOR SHALL BRING SUCH ITEMS TO THE ATTENTION OF THE ARCHITECT BEFORE SUBMISSION OF PROPOSAL FOR EXPLANATION OR CORRECTION OF SAME. AFTER THE SUBMISSION OF PROPOSAL, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL SUCH ITEMS. 8 THE CHARACTER AND SCOPE OF THE WORK ARE ILLUSTRATED BY THE DRAWINGS AND NOTES. TO INTERPRET AND EXPLAIN THE DRAWINGS OTHER INFORMATION DEEMED NECESSARY BY THE ARCHITECT WILL BE FURNISHED TO THE CONTRACTOR WHEN AND AS REQUIRED BY THE WORK, AND IT IS TO BE UNDERSTOOD THAT SAID ADDITIONAL INFORMATION OR DRAWINGS ARE TO BE OF EQUAL FORCE WITH THESE. 9 FULL SIZE OR LARGE SCALE DETAILS OR DRAWINGS SHALL GOVERN SMALL SCALE DRAWINGS WHICH THEY ARE INTENDED TO AMPLIFY. DETAILS OR CONDITIONS INDICATED FOR A PORTION OF THE WORK BUT NOT CARRIED OUT FULLY FOR OTHER PORTIONS SHALL APPLY THROUGHOUT TO ALL SIMILAR PORTIONS EXCEPT AS OTHERWISE SPECIFICALLY NOTED. IN EVERY CASE THE GREATER QUANTITY, OR A MORE EXPENSIVE ITEM OR METHOD SHALL BE ASSUMED OVER A LESSER QUANTITY OR A LESS EXPENSIVE ONE AND DIMENSIONS SHALL BE FIGURED RATHER THAN DETERMINED BY RULE OR SCALE. 10 ALL PARTITIONS ARE DIMENSIONED TO THE FINISHED FACES OF WALLS. ALL PARTITION THICKNESSES SHOWN ARE NOMINAL DIMENSIONS. 11 ALL MISCELLANEOUS WOOD BLOCKING, GROUNDS, FURRING AS REQUIRED, TO BE FIRE RETARDANT TREATED. 12 THE PROJECT HAS BEEN DESIGNED AND DETAILED FOR THE SPECIFIC MATERIALS AND EQUIPMENT SPECIFIED. NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT. IF THE SPECIFIED MATERIAL IS NOT AVAILABLE, THE CONTRACTOR SHALL PROPOSE AN ALTERNATE MATERIAL AND SHALL PROVIDE DRAWINGS, SAMPLES, SPECIFICATIONS, MANUFACTURER'S LITERATURE, PERFORMANCE DATA, ETC. IN ORDER THAT THE ARCHITECT CAN EVALUATE THE PROPOSED SUBSTITUTION. IF THE SUBSTITUTION AFFECTS A CORRELATED FUNCTION, ADJACENT CONSTRUCTION, OR THE WORK OF ANY OTHER CONTRACTOR OR TRADE, THE NECESSARY CHANGES AND MODIFICATIONS TO THE AFFECTED WORK SHALL BE SUBMITTED WITH THE SUBSTITUTION AND ACCOMPLISHED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER. NO REQUESTS FOR SUBSTITUTES WILL BE ENTERTAINED BY THE ARCHITECT DUE TO CONTRACTOR'S FAILURE TO ORDER MATERIALS IN A TIMELY MANNER. 13 THE STANDARD SPECIFICATIONS OF THE MANUFACTURERS APPROVED FOR USE IN THE PROJECT ARE HEREBY MADE A PART OF THESE NOTES WITH THE SAME FORCE AND EFFECT AS THOUGH HEREIN WRITTEN OUT IN FULL, EXCEPT THAT WHEREVER THE DRAWINGS REQUIRE HEAVIER MEMBERS, BETTER QUALITY MATERIALS OR ARE OTHERWISE MORE STRINGENT, THESE STRINGENT REQUIREMENTS SHALL GOVERN. 14 THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF HE CANNOT FOR ANY REASON COMPLY WITH ALL THE REQUIREMENTS OF THESE NOTES AND DRAWINGS. 15 THE CONTRACTOR SHALL COORDINATE AND SUPERVISE THE WORK OF ALL SUB-CONTRACTORS. HE SHALL BE RESPONSIBLE FOR GIVING ALL TRADES SUCH INFORMATION, PLANS OR DETAILS AS MAY BE REQUIRED FOR THE PROPER INSTALLATION AND COMPLETION OF THEIR WORK. 16 THE CONTRACTOR SHALL SUBMIT ALL FABRICATION SHOP DRAWINGS, SAMPLES, AND FIXTURE CUTS FOR THE ARCHITECT'S REVIEW AS REQUIRED AND/OR INDICATED ON DRAWINGS. THE ARCHITECT'S REVIEW SHALL NOT BE CONSTRUED AS AN INDICATION THAT SUBMITTAL IS CORRECT OR SUITABLE NOR THAT WORK REPRESENTED BY SUBMITTAL COMPLIES WITH THE DRAWINGS, EXCEPT AS TO MATTERS OF FINISH, COLOR, AND OTHER AESTHETIC MATTERS. ACTION NOTED ABOVE DOES NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY TO COORDINATE ALL TRADES AND TO CHECK QUANTITIES AND DIMENSIONS AGAINST CONDITIONS IN THE FIELD. CONTRACTORS AND ENGINEERS SHALL ASSUME RESPONSIBILITY FOR ALL ERRORS ON THEIR DRAWINGS. 17 ALL MATERIALS REQUIRED FOR THE PERFORMANCE OF THIS CONTRACT SHALL BE NEW AND OF THE BEST QUALITY OF KINDS SPECIFIED, ALL SUBJECT TO THE APPROVAL OF THE ARCHITECT. THE USE OF OLD OR SECOND-HAND MATERIALS IS STRICTLY FORBIDDEN. THE CONTRACTOR SHALL, IF REQUIRED, FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF MATERIALS AND WORKMANSHIP. MATERIALS SHALL BE USED IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. UPON REQUEST, THE MANUFACTURER'S REPRESENTATIVE SHALL GO TO THE SITE AND INSTRUCT THE MECHANICS IN THE USE OF THE MATERIALS OR SHALL SUPERVISE THEIR USE. 18 THE CONTRACTOR SHALL PROVIDE BLOCKING AT ALL LOCATIONS FOR SCHEDULED WALL CABINETS AND/OR TV WALL MOUNTING BRACKETS; REFER TO DRAWINGS FOR LOCATION. 16 GENERAL NOTES TO TOP OF (SEE OTHER WORD) TV TELEVISION TW TOP OF WALL TYP TYPICAL U -------------------------------------------- - U.O.N. UNLESS OTHERWISE NOTED V -------------------------------------------- - VCT VINYL COMPOSTION TILE VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VT VINYL TILE VWC VINYL WALL COVERING W -------------------------------------------- - W/O WITHOUT WC WATER CLOSET WD WOOD WP WORK POINT WR WATER RESISTENT/REPELLANT HW HOT WATER I -------------------------------------------- - ID INSIDE DIAMETER IN INCH INCL INCLUDED / INCLUDING INSUL INSULATION INT INTERIOR INV INVERT J -------------------------------------------- - JAN JANITOR JC JANITOR'S CLOSET L -------------------------------------------- - LAB LABORATORY LAM LAMINATE LAV LAVATORY LB POUND LF LINEAR FOOT LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL M -------------------------------------------- - MACH MACHINE MAINT MAINTENANCE MATL MATERIAL MAX MAXIMUM MBL MARBLE MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY PLYWOOD MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINUMUM MISC MISCELLANEOUS MM MILLIMETER MO MASONRY OPENING MTD MOUNTED MTG MOUNTING N NORTH N -------------------------------------------- - NA NOT APPLICABLE NC NOISE CRITERIA NIC NOT IN CONTACT NOM NOMINAL NTS NOT TO SCALE O -------------------------------------------- - OC ON CENTER OD OUTSIDE DIAMETER/DIMENSION OFCI OWNER FURNISHED, CONTR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OPP OPPOSITE ORD OVERFLOW ROOF DRAIN OVHD OVERHEAD P -------------------------------------------- - P. PAINT PBD PARTICLEBOARD PC PRECAST CONCRETE PERF PERFORATED PERIM PERIMETER PERP PERPENDICULAR PL PLATE PLAM PLASTIC LAMINATE PLF POUNDS PER LINEAR FOOT PR PAIR PREFAB PREFABRICATED PROJ PROJECT PSF POUNDS PER SQUARE FOOT PT POINT PTD PAINTED Q -------------------------------------------- - QT QUARRY TILE QTY QUANTITY R RADIUS OR RISER R -------------------------------------------- - RB RESILIENT BASE RCP REFLECTED CEILING PLAN RD ROOF DRAIN REF REFERENCE REINF REINFORCED / REINFORCING REQ'D REQUIRED REV REVISION/REVISED RM ROOM RO ROUGH OPENING RWL RAIN WATER LEADER S -------------------------------------------- - SC SOLID CORE SCHED SCHEDULE SF SQUARE FEET/FOOT SIM SIMILAR SP STANDPIPE SPEC SPECIFICATION SQ SQUARE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL T -------------------------------------------- - T&G TONGUE AND GROOVE T. TREAD TC TOP OF CURB TEL TELEPHONE OR TELECOM (E) EXISTING (N) NEW (R) RELOCATED A: -------------------------------------------- - AC AIR CONDITIONING ACC ACCESSIBLE ACT ACOUSTICAL CEILING TILE ADD ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE ARCH ARCHITECTURAL AV AUDIO VISUAL B -------------------------------------------- - BD BOARD BLDG BUILDING BO BOTTOM OF BUR BUILT-UP ROOFING C -------------------------------------------- - CB CATCH BASIN CG CORNER GUARD CIP CAST-IN-PLACE CJ CONTROL / CONSTRUCTION JOINT CL CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CO CLEANOUT COL COLUMN CONC CONCRETE CONT CONTINUOUS COORD COORDINATE CORR CORRIDOR CT CERAMIC TILE CW COLD WATER D -------------------------------------------- - DEMO DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPENSER DN DOWN DO DOOR OPENING DP DIMENSION POINT DR DOOR DS DOWNSPOUT DW DISHWASHER DWG DRAWING E -------------------------------------------- - EA EACH EFS EXTERIOR INSULATION & FINISH SYSTEM EIFS EXTERIOR FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ELECT ELECTRICAL ELEV ELEVATOR EMERG EMERGENCY EQ EQUAL EQUIP EQUIPMENT EWC ELECTRICAL WATER COOLER EXH EXHAUST EXIST EXISTING EXT EXTERIOR F -------------------------------------------- - FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF&E FURNITURE, FINISHES, & EQUIPMENT FFEL FINISH FLOOR ELEVATION FHC FIRE HOSE CABINET FL FLOOR FND FOUNDATION FO FACE OF FP FIRE PROTECTION FPG FIREPROOFING FRTW FIRE RETARDANT TREATED WOOD FT FEET FURN FURNITURE FWC FABRIC WALLCOVERING FWP FABRIC WRAPPED PANEL G GROUND G -------------------------------------------- - GA GAUGE / GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS RIBER REINFORCED GYPSUM GL GLASS GYPBD GYPSUM WALLBOARD H -------------------------------------------- - HB HOSE BIB HC HOLLOW CORE HCP HANDICAPPED HDWD HARDWOOD HDWR HARDWARE HM HOLLOW METAL (STEEL FRAME) HORIZ HORIZONTAL HR HOUR HVAC HEATING, VENTILATION, AIR CONDITIONING 8 ABBREVIATIONS 4 SYMBOL LEGEND 1 GRAPHICS LEGEND

Transcript of SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision...

Page 1: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

F.E.C.

EL: 100'-0"

A 1.01

3

4

1

2

A101

1A101

101

000

1

ROOM

202A

150 SF

A

A

ENLARGED PLAN / DETAIL IDENTIFICATION

SECTION IDENTIFICATION

INTERIOR ELEVATION IDENTIFICATION

DIMENSION TO CENTERLINE

DIMENSION LINE

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE REMOVED

NEW CONSTRUCTION

CENTERLINE

DOOR NUMBER

WINDOW NUMBER

PARTITION TYPE

Room Name

ELEVATION MARKER

SPOT ELEVATION

ROOF PITCH

KEYED NOTE

EXTERIOR ELEVATION IDENTIFICATION

FURNITURE TAG

NORTH ARROW

DRAWING REVISION / REVISION NUMBER

A101

1

SHEET NUMBER

COLUMN GRID TAG

ACCESSIBLE ELEMENT

CLEAR FLOOR SPACES FOR WHEELCHAIR: 2'-6" x 4'-0" AND 5'-0" DIAMETER

DIRECTION OF DOWNWARD SLOPE

STAIR TAG

ROOM FINISH TAG

3' - 0"

3' - 0"

WALL

CEILING

BASE

FLOOR

SEMI RECESSED FIRE EXTINGUISHER

12

6.0

1

N

R @ 7 1/2"20

XX

XX

WALLCEILING

WALL FINISH TAG

FINISH TRANSITION TAG

0

Detail NumberSheet Number

Detail NumberSheet Number

Elevation NumberSheet Number

Sheet Number SequenceSheet Type

Discipline

Elevation NumberSheet Number

Room Number

Room Area (If Displayed)

ROOM TAG

CL

ACOUSTICAL TILE

ALUMINUM

CARPET

DISTURBED EARTH

UNDIST. EARTH

EIFS

GLASS ELEVATION

GLASS SECTION

GYPSUM BOARD

HOMOSOTE

INSULATION - RIGID

GRAVEL

MASONRY -CONC. BLOCK

PLYWOOD

SAND

SHINGLE

STEEL

STONE

WOOD

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICESDIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.242 TRUMBULL STREET HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.17.2014 DD SUBMISSION

7.14.2017 FOR BIDDING

JULY 14, 2017

As indicated

GENERAL NOTES, SYMBOLS,GRAPHICS LEGEND

G1.00

AF

CB

19 FOR THE EXECUTION OF THE WORK TO BE PERFORMED UNDER THIS CONTRACT AND FOR THEMANUFACTURE OR TRANSPORTATION OF ANY OF THE MATERIALS OR EQUIPMENT TO BE USED ORINSTALLED, THE CONTRACTOR SHALL EMPLOY ONLY SUCH LABOR THROUGHOUT AS WILL NOTINTERFERE WITH THE SPEEDY AND UNINTERRUPTED COMPLETION OF THE PROJECT. ALL WORKSHALL BE DONE BY MECHANICS SKILLED IN THEIR TRADE AND SHALL BE INSTALLED IN A NEAT ANDWORKMANLIKE MANNER IN ACCORDANCE WITH THE BEST TRADE PRACTICES.

20 ANY MATERIALS DELIVERED OR WORK PERFORMED, CONTRARY TO THE DRAWINGS ANDSPECIFICATIONS AND APPROVED SHOP DRAWINGS, SHALL BE REMOVED BY THE CONTRACTOR AT HISOWN EXPENSE, AND THE SAME SHALL BE REPLACED WITH OTHER MATERIALS OR WORKSATISFACTORY TO THE ARCHITECT. THE CONTRACTOR SHALL ALSO ASSUME THE COST OFREPLACING THE WORK WHICH MAY BE DISTURBED.

21 THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY AND ACCURATELY LAYING OUT THEWORK AND FOR THE LINES AND MEASUREMENTS HEREIN. HE SHALL ESTABLISH NECESSARYREFERENCE LINES AND PERMANENT BENCH MARKS FROM WHICH BUILDING LINES AND ELEVATIONSSHALL BE TAKEN. ELEVATION HEIGHTS OF ALL WORK INCLUDING BUT NOT LIMITED TO SOFFITS,CEILINGS, DOORS, HOLLOW METAL SHALL BE TRUE AND LEVEL WITHIN A MAXIMUM TOLERANCE OF1/8" OVERALL THE ENTIRE PROJECT.

22 FOR ALL PARTITIONS REFER TO PARTITION SYMBOLS ON DRAWINGS AND THE PARTITION TYPEDETAILS WHICH SHOWS PARTITION CORES AND FINISHES.

23 A. THE PREMISES AND THE JOB SITE SHALL BE MAINTAINED IN A REASONABLY NEAT AND ORDERLYCONDITION AND KEPT FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND RUBBISH DURINGTHE ENTIRE CONSTRUCTION PERIOD. REMOVE CRATES, CARTONS AND OTHER FLAMMABLE WASTEMATERIALS OR TRASH FROM THE WORK AREAS AT THE END OF EACH WORKING DAY.

B. ELECTRICAL CLOSETS, PIPE AND DUCT SHAFTS, CHASES, FURRED SPACES AND SIMILAR SPACESWHICH ARE GENERALLY UNFINISHED SHALL BE CLEANED AND LEFT FREE FROM RUBBISH, LOOSEPLASTER, MORTAR DRIPPINGS, EXTRANEOUS CONSTRUCTION MATERIALS, DIRT AND DUST.

C. CARE SHALL BE TAKEN BY WORKMEN NOT TO MARK, SOIL, OR OTHERWISE DEFACE FINISHEDSURFACES. IN THE EVENT THAT FINISHED SURFACES BECOME DEFACED, THE CONTRACTOR ISRESPONSIBLE FOR CLEANING AND RESTORING SUCH SURFACES TO THEIR ORIGINAL CONDITION. IFTHIS IS NOT POSSIBLE, DAMAGED SURFACES SHALL BE REPLACED.

D. CLEAN UP IMMEDIATELY UPON COMPLETION OF EACH TRADE'S WORK.

E. CLEAN AREAS OF THE BUILDING IN WHICH PAINTING AND FINISHING WORK IS TO BE PERFORMEDJUST PRIOR TO THE START OF THIS WORK, AND MAINTAIN THESE AREAS IN SATISFACTORYCONDITION FOR PAINTING AND FINISHING.

F. THIS CLEANING INCLUDES THE REMOVAL OF TRASH AND RUBBISH FROM THESE AREAS, BROOMCLEANING OF FLOORS, THE REMOVAL OF ANY PLASTER, MORTAR, DUST AND OTHER EXTRANEOUSMATERIALS FROM FINISH SURFACES, INCLUDING BUT NOT LIMITED TO, MISCELLANEOUS METAL,WOODWORK, PLASTER, GYPSUM DRYWALL, MASONRY, CONCRETE, MECHANICAL AND ELECTRICALEQUIPMENT, PIPING, DUCTWORK, CONDUIT, AND SURFACES VISIBLE AFTER GRILLES, REGISTERS ANDOTHER SUCH FIXTURES OR DEVICES ARE IN PLACE.

G. IN ADDITION TO THE CLEANING SPECIFIED ABOVE AND THE MORE SPECIFIC CLEANING WHICHMAY BE REQUIRED IN VARIOUS SECTIONS OF THE SPECIFICATIONS, THE PREMISES SHALL BEPREPARED FOR OCCUPANCY BY:

(i)A THOROUGH CLEANING THROUGHOUT INCLUDING WASHING OR CLEANING BY OTHER APPROVEDMETHODS OF ALL FLOORS AND SURFACES ON WHICH DIRT OR DUST HAS COLLECTED AND BYWASHING GLASS, REMOVING ALL PAINT, PUTTY AND STAINS THEREFROM.

(ii)PROVIDING AND MAINTAINING PROTECTION OF EXISTING AND INSTALLED PORTIONS OF THE WORK.

(iii)LEAVING ALL FIXTURES AND EQUIPMENT IN AN UNDAMAGED, BRIGHT, CLEAN, POLISHEDCONDITION.

(iv)CLEAN AND POLISH ALL HARDWARE, AND OTHER METAL WORK.

(v)FOR FINAL CLEANING, CONTRACTOR SHALL ENGAGE THE SERVICES OF A PROFESSIONALCLEANING COMPANY TO ACCOMPLISH THE FOLLOWING: REMOVAL OF PUTTY STAINS AND PAINTSPOTS, WASHING AND POLISHING OF GLASS, CLEANING AND POLISHING OF ALL EXPOSED FINISHHARDWARE, AND A THOROUGH CLEANING OF ALL SURFACES; RESILIENT TILE / SHEET VINYLFLOORING POLISHED & BUFFED

24 THE CONTRACTOR SHALL KEEP THE ARCHITECT INFORMED OF THE PROGRESS OF HIS WORK. NOWORK SHALL BE CLOSED OR COVERED UNTIL IT HAS BEEN DULY INSPECTED AND APPROVED.SHOULD UNINSPECTED WORK BE COVERED, THE CONTRACTOR SHALL, AT HIS OWN EXPENSE,UNCOVER ALL SUCH WORK SO THAT IT CAN BE PROPERLY INSPECTED AND AFTER SUCH INSPECTION,HE SHALL PROPERLY REPAIR AND REPLACE ALL WORK INTERFERED WITH.

25 THE WORK IS SUBJECT TO INSPECTION BY THE ARCHITECT AND ACCEPTANCE BY THE OWNER.

26 PROTECT OWNER'S PROPERTY, EQUIPMENT AND EMPLOYEES FROM INJURY AND DAMAGE.

27 ALL HVAC, PLUMBING, SPRINKLER AND ELECTRICAL LINES ARE TO BE COORDINATED SO THAT NOCONFLICTS OCCUR. ANY CONFLICTS WHICH RESULT IN A RELOCATION OF A FINISHED SURFACE MUSTBE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION.

28 CONTRACTOR SHALL CONSULT WITH ELECTRICAL AND PLUMBING SUB-CONTRACTORS FORLOCATIONS OF CONDUIT AND PIPES IN FOUNDATION, SLABS ON GRADE, AND EXTERIOR WALLS ANDSHALL INSTALL WATERTIGHT PIPE SLEEVES AT THEIR RESPECTIVE LOCATIONS.

29 A SET OF THE INSTRUCTION MANUALS AND INSTALLATION INSTRUCTIONS OF ALL EQUIPMENT ANDACCESSORIES INSTALLED IN THIS JOB SHALL BE KEPT BY THE CONTRACTOR AND TURNED OVER TOTHE OWNER AT THE COMPLETION OF THE JOB. IN ADDITION, AS-BUILT DRAWINGS OF THECOMPLETED WORK ARE TO BE COMPLETED, SIGNED AND SEALED, AND DELIVERED TO THEARCHITECT AND OWNER AT THE COMPLETION OF THE JOB.

30 PROVIDE ADEQUATE BACKUP AND BLOCKING FOR ALL WALL OR CEILING MOUNTED EQUIPMENT,ARCHITECTURAL WOODWORK, HANDRAILS, LIGHTING OR OTHER MISCELLANEOUS ITEMS AS SHOWNON DRAWINGS TO ASSURE A SECURE INSTALLATION.

31 SUBMITTALS THAT REQUIRE THE REVIEW OF THE ARCHITECT/ENGINEERING TEAM SHALL BEDELIVERED IN DIGITAL FORMAT, AND IF REQUIRED BY THE ARCHITECTURE/ENGINEERING TEAM, BESUBMITTED AS HARDCOPY AS WELL. A SEVEN (7) BUSINESS DAY PERIOD OF TIME WILL BE ALOTTEDFOR ARCHITECT'S/ENGINEER'S REVIEW OF THE CONSTRUCTION SUBMITTAL, AND IT CANNOT BEGUARANTEED THAT AN EXPEDITED SCHEDULE CAN BE ACCOMMODATED.

32 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING OR OBTAINING SHOP DRAWINGS FROM THESUBCONTRACTORS AND MANUFACTURERS. THE APPROVAL AND SUBMITTAL OR SHOP DRAWINGS TOTHE ARCHITECT REPRESENTS THAT THE CONTRACTOR HAS REVIEWED AND VERIFIED THE USE OFAPPROPRIATE MATERIALS, PROPER FIELD MEASUREMENTS, FIELD CONSTRUCTION REQUIREMENTS,AND HAVE COORDINATED THE INFORMATION CONTAINED IN THE SUBMITTAL. DEVIATIONS FROM THECONTRACT DOCUMENTS MUST BE CALLED TO THE ATTENTION OF THE ARCHITECT IN WRITING ANDREQUIRES SPECIFIC APPROVAL OF THE ARCHITECT. ARCHITECTURAL APPROVAL OF THE SHOPDRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF ERRORS OROMISSIONS, PER AIA DOCUMENT A201-2007 STANDARDS.

33 ALL QUESTIONS TO THE ARCHITECT/ENGINEERING TEAM SHALL BE SUBMITTED AS REQUEST'S FORINFORMATION (RFI'S), WITH THE CONSTRUCTION MANAGER'S LETTERHEAD. THE CONSTRUCTIONMANAGER WILL PROVIDE A NUMBER TO THE RFI. A ONE (1) WEEK PERIOD OF TIME WILL BE ALOTTEDFOR ARCHITECTURAL/ENGINEERING REVIEW OF THE RFI. ALL CORRESPONDENCE REGARDING RFI'SWILL BE FROM THE CONSTRUCTION MANAGER TO THE ARCHITECT. THE ARCHITECT WILLDISSEMINATE THE INFORMATION TO THE APPROPRIATE ENGINEER'S IF REQUIRED. NOSUB-CONTRACTOR IS TO CONTACT THE ARCHITECT OR ENGINEER WITH A QUESTION DIRECTLY; ALLQUESTIONS TO THE ARCHITECTURE/ENGINEERING TEAM SHALL BE SENT THROUGH THECONSTRUCTION MANAGER.

1 THE TERM CONTRACTOR IS USED IN THESE NOTES TO IDENTIFY THE PARTY WHO IS CONTRACTED TOTHE OWNER AND WHO CAUSES THE WORK OF THE CONTRACT TO BE PERFORMED EITHER BY HISOWN FORCES OR BY OTHER CONTRACTORS RETAINED BY HIM.

2 THE CONTRACTOR SHALL DO THIS WORK IN ACCORDANCE WITH LOCAL LAWS AND ORDINANCESHAVING JURISDICTION. OTHER THAN THE BULDING PERMIT, THE CONTRACTOR SHALL OBTAIN ALLOTHER PERMITS AND APPROVALS AS REQUIRED BY LAW FOR THE COMPLETION OF THE WORK ANDISSUANCE OF A FULL CERTIFICATE OF OCCUPANCY.

3 THE SUBMISSION OF A PROPOSAL BY THE CONTRACTOR WILL BE CONSTRUED AS EVIDENCE THAT ACAREFUL AND THOROUGH EXAMINATION OF THE SITE HAS BEEN MADE AND LATER CLAIMS FORLABOR, MATERIALS OR EQUIPMENT REQUIRED OR FOR DIFFICULTIES ENCOUNTERED, WHICH COULDHAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED. ITSHALL ALSO CONSTITUTE A REPRESENTATION THAT THE CONTRACTOR HAS CHECKED AND VERIFIEDALL QUANTITIES, WORK AND MATERIALS INVOLVED AND THAT HE SHALL TAKE RESPONSIBILITY FORANY DEFICIENCIES THEREIN.

4 BEFORE ORDERING ANY MATERIAL OR DOING ANY WORK, EACH TRADE SHALL VERIFY ALLMEASUREMENTS IN THE FIELD AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME. NOEXTRA CHARGE OR COMPENSATION WILL BE ALLOWED ON ACCOUNT OF DIFFERENCE BETWEENACTUAL DIMENSIONS AND THE MEASUREMENTS INDICATED ON THE DRAWINGS; ANY DISCREPANCIESBETWEEN THE DRAWINGS AND FIELD CONDITIONS WHICH MAY BE FOUND SHALL BE SUBMITTED TOTHE ARCHITECT FOR CONSIDERATION AND CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

5 ALL OF THE ARCHITECT'S DRAWINGS AND CONSTRUCTION NOTES ARE COMPLIMENTARY AND WHATIS CALLED FOR BY EITHER WILL BE BINDING AS IF CALLED FOR BY ALL: ANY WORK SHOWN ORREFERRED TO ON ANY ONE DRAWING SHALL BE PROVIDED AS THOUGH SHOWN ON ALL DRAWINGS.WHENEVER AN ITEM IS SPECIFIED AND/OR SHOWN ON THE DRAWINGS BY DETAIL OR REFERENCE ITSHALL BE CONSIDERED TYPICAL FOR OTHER ITEMS WHICH ARE OBVIOUSLY INTENDED TO BE THESAME EVEN THOUGH NOT SO DESIGNATED OR SPECIFICALLY NAMED BUT DO SERVE THE SAMEFUNCTION.

6 THE WORK TO BE PERFORMED CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT, TOOLS,TRANSPORTATION, SUPPLIES, FEES, MATERIALS, AND SERVICES IN ACCORDANCE WITH THESENOTES AND DRAWINGS AND PERFORMING ALL OPERATIONS NECESSARY TO CONSTRUCT ANDINSTALL COMPLETE AND IN SATISFACTORY CONDITION THE VARIOUS MATERIALS AND EQUIPMENT ATTHE LOCATIONS SHOWN. IT IS INTENDED THAT THE DRAWINGS INCLUDE EVERYTHING REQUISITEAND NECESSARY TO FINISH THE ENTIRE WORK PROPERLY, NOTWITHSTANDING THE FACT THATEVERY ITEM NECESSARILY INVOLVED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. ANY ITEMWHICH MAY BE REASONABLY CONSTRUED AS INCIDENTAL TO THE PROPER AND SATISFACTORYCOMPLETION OF THE WORK IN ACCORDANCE WITH THE INTENT OF THESE NOTES AND DRAWINGS ISHEREBY INCLUDED.

7 THE CONTRACTOR SHALL ABIDE BY AND COMPLY WITH THE TRUE INTENT AND MEANING OF THEDRAWINGS AND NOTES TAKEN AS A WHOLE AND SHALL NOT AVAIL HIMSELF OF ANY OBVIOUSERRORS OR OMISSIONS, SHOULD ANY EXIST. SHOULD ANY ERROR OR DISCREPANCY APPEAR ORANY DOUBT ARISE AS TO THE TRUE MEANING OF THE DRAWINGS OR NOTES, THE CONTRACTORSHALL BRING SUCH ITEMS TO THE ATTENTION OF THE ARCHITECT BEFORE SUBMISSION OFPROPOSAL FOR EXPLANATION OR CORRECTION OF SAME. AFTER THE SUBMISSION OF PROPOSAL,THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL SUCH ITEMS.

8 THE CHARACTER AND SCOPE OF THE WORK ARE ILLUSTRATED BY THE DRAWINGS AND NOTES. TOINTERPRET AND EXPLAIN THE DRAWINGS OTHER INFORMATION DEEMED NECESSARY BY THEARCHITECT WILL BE FURNISHED TO THE CONTRACTOR WHEN AND AS REQUIRED BY THE WORK, ANDIT IS TO BE UNDERSTOOD THAT SAID ADDITIONAL INFORMATION OR DRAWINGS ARE TO BE OF EQUALFORCE WITH THESE.

9 FULL SIZE OR LARGE SCALE DETAILS OR DRAWINGS SHALL GOVERN SMALL SCALE DRAWINGS WHICHTHEY ARE INTENDED TO AMPLIFY. DETAILS OR CONDITIONS INDICATED FOR A PORTION OF THE WORKBUT NOT CARRIED OUT FULLY FOR OTHER PORTIONS SHALL APPLY THROUGHOUT TO ALL SIMILARPORTIONS EXCEPT AS OTHERWISE SPECIFICALLY NOTED. IN EVERY CASE THE GREATER QUANTITY,OR A MORE EXPENSIVE ITEM OR METHOD SHALL BE ASSUMED OVER A LESSER QUANTITY OR A LESSEXPENSIVE ONE AND DIMENSIONS SHALL BE FIGURED RATHER THAN DETERMINED BY RULE ORSCALE.

10 ALL PARTITIONS ARE DIMENSIONED TO THE FINISHED FACES OF WALLS. ALL PARTITIONTHICKNESSES SHOWN ARE NOMINAL DIMENSIONS.

11 ALL MISCELLANEOUS WOOD BLOCKING, GROUNDS, FURRING AS REQUIRED, TO BE FIRE RETARDANTTREATED.

12 THE PROJECT HAS BEEN DESIGNED AND DETAILED FOR THE SPECIFIC MATERIALS AND EQUIPMENTSPECIFIED. NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE EXPRESS WRITTEN CONSENT OF THEARCHITECT. IF THE SPECIFIED MATERIAL IS NOT AVAILABLE, THE CONTRACTOR SHALL PROPOSE ANALTERNATE MATERIAL AND SHALL PROVIDE DRAWINGS, SAMPLES, SPECIFICATIONS,MANUFACTURER'S LITERATURE, PERFORMANCE DATA, ETC. IN ORDER THAT THE ARCHITECT CANEVALUATE THE PROPOSED SUBSTITUTION. IF THE SUBSTITUTION AFFECTS A CORRELATEDFUNCTION, ADJACENT CONSTRUCTION, OR THE WORK OF ANY OTHER CONTRACTOR OR TRADE, THENECESSARY CHANGES AND MODIFICATIONS TO THE AFFECTED WORK SHALL BE SUBMITTED WITHTHE SUBSTITUTION AND ACCOMPLISHED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THEOWNER. NO REQUESTS FOR SUBSTITUTES WILL BE ENTERTAINED BY THE ARCHITECT DUE TOCONTRACTOR'S FAILURE TO ORDER MATERIALS IN A TIMELY MANNER.

13 THE STANDARD SPECIFICATIONS OF THE MANUFACTURERS APPROVED FOR USE IN THE PROJECTARE HEREBY MADE A PART OF THESE NOTES WITH THE SAME FORCE AND EFFECT AS THOUGHHEREIN WRITTEN OUT IN FULL, EXCEPT THAT WHEREVER THE DRAWINGS REQUIRE HEAVIERMEMBERS, BETTER QUALITY MATERIALS OR ARE OTHERWISE MORE STRINGENT, THESE STRINGENTREQUIREMENTS SHALL GOVERN.

14 THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF HE CANNOT FOR ANY REASONCOMPLY WITH ALL THE REQUIREMENTS OF THESE NOTES AND DRAWINGS.

15 THE CONTRACTOR SHALL COORDINATE AND SUPERVISE THE WORK OF ALL SUB-CONTRACTORS. HESHALL BE RESPONSIBLE FOR GIVING ALL TRADES SUCH INFORMATION, PLANS OR DETAILS AS MAY BEREQUIRED FOR THE PROPER INSTALLATION AND COMPLETION OF THEIR WORK.

16 THE CONTRACTOR SHALL SUBMIT ALL FABRICATION SHOP DRAWINGS, SAMPLES, AND FIXTURE CUTSFOR THE ARCHITECT'S REVIEW AS REQUIRED AND/OR INDICATED ON DRAWINGS. THE ARCHITECT'SREVIEW SHALL NOT BE CONSTRUED AS AN INDICATION THAT SUBMITTAL IS CORRECT OR SUITABLENOR THAT WORK REPRESENTED BY SUBMITTAL COMPLIES WITH THE DRAWINGS, EXCEPT AS TOMATTERS OF FINISH, COLOR, AND OTHER AESTHETIC MATTERS. ACTION NOTED ABOVE DOES NOTRELIEVE THE CONTRACTOR FROM RESPONSIBILITY TO COORDINATE ALL TRADES AND TO CHECKQUANTITIES AND DIMENSIONS AGAINST CONDITIONS IN THE FIELD. CONTRACTORS AND ENGINEERSSHALL ASSUME RESPONSIBILITY FOR ALL ERRORS ON THEIR DRAWINGS.

17 ALL MATERIALS REQUIRED FOR THE PERFORMANCE OF THIS CONTRACT SHALL BE NEW AND OF THEBEST QUALITY OF KINDS SPECIFIED, ALL SUBJECT TO THE APPROVAL OF THE ARCHITECT. THE USEOF OLD OR SECOND-HAND MATERIALS IS STRICTLY FORBIDDEN. THE CONTRACTOR SHALL, IFREQUIRED, FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF MATERIALS ANDWORKMANSHIP. MATERIALS SHALL BE USED IN ACCORDANCE WITH MANUFACTURER'S PRINTEDINSTRUCTIONS. UPON REQUEST, THE MANUFACTURER'S REPRESENTATIVE SHALL GO TO THE SITEAND INSTRUCT THE MECHANICS IN THE USE OF THE MATERIALS OR SHALL SUPERVISE THEIR USE.

18 THE CONTRACTOR SHALL PROVIDE BLOCKING AT ALL LOCATIONS FOR SCHEDULED WALL CABINETSAND/OR TV WALL MOUNTING BRACKETS; REFER TO DRAWINGS FOR LOCATION.

16 GENERAL NOTES

TO TOP OF (SEE OTHER WORD)

TV TELEVISION

TW TOP OF WALL

TYP TYPICAL

U ---------------------------------------------

U.O.N. UNLESS OTHERWISE NOTED

V ---------------------------------------------

VCT VINYL COMPOSTION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VT VINYL TILE

VWC VINYL WALL COVERING

W ---------------------------------------------

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WP WORK POINT

WR WATERRESISTENT/REPELLANT

HW HOT WATER

I ---------------------------------------------

ID INSIDE DIAMETER

IN INCH

INCL INCLUDED / INCLUDING

INSUL INSULATION

INT INTERIOR

INV INVERT

J ---------------------------------------------

JAN JANITOR

JC JANITOR'S CLOSET

L ---------------------------------------------

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LB POUND

LF LINEAR FOOT

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

M ---------------------------------------------

MACH MACHINE

MAINT MAINTENANCE

MATL MATERIAL

MAX MAXIMUM

MBL MARBLE

MDF MEDIUM DENSITYFIBERBOARD

MDO MEDIUM DENSITY OVERLAYPLYWOOD

MECH MECHANICAL

MEP MECHANICAL, ELECTRICAL,PLUMBING

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINUMUM

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

MTD MOUNTED

MTG MOUNTING

N NORTH

N ---------------------------------------------

NA NOT APPLICABLE

NC NOISE CRITERIA

NIC NOT IN CONTACT

NOM NOMINAL

NTS NOT TO SCALE

O ---------------------------------------------

OC ON CENTER

OD OUTSIDEDIAMETER/DIMENSION

OFCI OWNER FURNISHED, CONTRINSTALLED

OFOI OWNER FURNISHED, OWNERINSTALLED

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

OVHD OVERHEAD

P ---------------------------------------------

P. PAINT

PBD PARTICLEBOARD

PC PRECAST CONCRETE

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PL PLATE

PLAM PLASTIC LAMINATE

PLF POUNDS PER LINEAR FOOT

PR PAIR

PREFAB PREFABRICATED

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PT POINT

PTD PAINTED

Q ---------------------------------------------

QT QUARRY TILE

QTY QUANTITY

R RADIUS OR RISER

R ---------------------------------------------

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFERENCE

REINF REINFORCED / REINFORCING

REQ'D REQUIRED

REV REVISION/REVISED

RM ROOM

RO ROUGH OPENING

RWL RAIN WATER LEADER

S ---------------------------------------------

SC SOLID CORE

SCHED SCHEDULE

SF SQUARE FEET/FOOT

SIM SIMILAR

SP STANDPIPE

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

T ---------------------------------------------

T&G TONGUE AND GROOVE

T. TREAD

TC TOP OF CURB

TEL TELEPHONE OR TELECOM

(E) EXISTING

(N) NEW

(R) RELOCATED

A: ---------------------------------------------

AC AIR CONDITIONING

ACC ACCESSIBLE

ACT ACOUSTICAL CEILING TILE

ADD ADDITIONAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

ARCH ARCHITECTURAL

AV AUDIO VISUAL

B ---------------------------------------------

BD BOARD

BLDG BUILDING

BO BOTTOM OF

BUR BUILT-UP ROOFING

C ---------------------------------------------

CB CATCH BASIN

CG CORNER GUARD

CIP CAST-IN-PLACE

CJ CONTROL / CONSTRUCTIONJOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

COORD COORDINATE

CORR CORRIDOR

CT CERAMIC TILE

CW COLD WATER

D ---------------------------------------------

DEMO DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DN DOWN

DO DOOR OPENING

DP DIMENSION POINT

DR DOOR

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

E ---------------------------------------------

EA EACH

EFS EXTERIOR INSULATION &FINISH SYSTEM

EIFS EXTERIOR FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELECT ELECTRICAL

ELEV ELEVATOR

EMERG EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRICAL WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXT EXTERIOR

F ---------------------------------------------

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHERCABINET

FF&E FURNITURE, FINISHES, &EQUIPMENT

FFEL FINISH FLOOR ELEVATION

FHC FIRE HOSE CABINET

FL FLOOR

FND FOUNDATION

FO FACE OF

FP FIRE PROTECTION

FPG FIREPROOFING

FRTW FIRE RETARDANT TREATEDWOOD

FT FEET

FURN FURNITURE

FWC FABRIC WALLCOVERING

FWP FABRIC WRAPPED PANEL

G GROUND

G ---------------------------------------------

GA GAUGE / GAGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCEDCONCRETE

GFRG GLASS RIBER REINFORCEDGYPSUM

GL GLASS

GYPBD GYPSUM WALLBOARD

H ---------------------------------------------

HB HOSE BIB

HC HOLLOW CORE

HCP HANDICAPPED

HDWD HARDWOOD

HDWR HARDWARE

HM HOLLOW METAL (STEELFRAME)

HORIZ HORIZONTAL

HR HOUR

HVAC HEATING, VENTILATION, AIRCONDITIONING

8 ABBREVIATIONS 4 SYMBOL LEGEND

1 GRAPHICS LEGEND

Page 2: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

TYPICAL LOCATION FOR TWO ROWS OF LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC.

3' -

2"

FINISH FLOOR

POWER AND TELEPHONE RECEPTACLE

DOOR LEVER, PULL

LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. CLUSTER (SEE PLAN FOR QUANTITY OF EACH CLUSTER)

THERMOSTAT, INTERCOM OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER

FIRE ALARM DEVICE

DOOR FRAME

COAT HOOK

DOOR OR OPENING

1' - 0"

TYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, WALL HUNG TELEPHONE, FIRE ALARM DEVICES, FIRE EXTINGUISHER, ETC. ON WALLS 2'-6" OF LENGTH OR LESS

FINISH FLOOR

POWER AND TELEPHONE RECEPTACLE

LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. CLUSTER (SEE PLAN FOR QUANTITY OF EACH CLUSTER)

THERMOSTAT, INTERCOM OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER

FIRE ALARM DEVICE

DOOR FRAME OR CORNER

EQ.

DOOR OR OPENING

WALL OR CORNER

EQ.

IF 2' - 6" OR LESS

REFER TO 8/G1.01 FOR PLAN DIAGRAMTYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, WALL HUNG TELEPHONE, FIRE ALARM DEVICES, FIRE EXTINGUISHER, ETC. FOR DOORS AT OPEN POSITION

FINISH FLOOR

LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. CLUSTER (SEE PLAN FOR QUANTITY OF EACH CLUSTER)

THERMOSTAT, INTERCOM OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER

FIRE ALARM DEVICE

DOOR ATOPEN POSITION

6"

TYPICAL LOCATION FOR FIRE ALARM PULL STATION, WARDEN STATION & FIRE EXTINGUISHER CABINETS

OP

ER

AB

LE C

OM

PO

NE

NT

4' -

0"

MA

X T

O H

IGH

ES

T

OP

ER

AB

LE C

OM

PO

NE

NT

4' -

0"

MA

X T

O H

IGH

ES

T

FIRE ALARM PULL STATION

WARDEN STATION

FIRE EXTINGUISHER CABINET

U.O

.N.

1' -

6"

6"

EQ EQ EQ EQ

FINISH FLOOR

POWER AND TELEPHONE RECEPTACLE CENTER BETWEEN PANEL AND JOINT

TYPICAL WALL PANEL JOINT

TYPICAL HEIGHTS OF MILLWORK COUNTERTOPS, WORKSURFACES, AND TRANSACTIONS SURFACES, UNLESS OTHERWISE NOTED ON ELEVATIONS OR PLANS

FINISH FLOOR

MILLWORK WORKSURFACE

CABINET / PANTRY MILLWORK & COUNTERTOP

TRANSACTION OR BAR HEIGHT COUNTERTOP

2' -

5"

2' -

10"

3' -

6"

6"

OUTLET LOCATION

*

*

**

TO

ILE

T S

EA

T1'

- 5

" T

.O.

LINE OF TOILET1' - 4" TO CENTER-

TOILET FRONT ELEVATION(1 1/2" DIAMETER GRAB

BARS ASSUMED IN DIAGRAM)

OF

18"

VE

RT

ICA

L G

RA

B B

AR

3' -

4"

TO

BO

TT

OM

CENTERLINE OF GRAB BAR

3' - 4" FROM SCHEDULEDWALL FINISH FACE TO

CA

LL F

OR

AID

1' -

0"

TO

BO

TT

OM

OF

CO

RD

FO

R

TOILET SIDE ELEVATION(1 1/2" DIAMETER GRAB BARS

ASSUMED IN DIAGRAM)

RE

CE

PT

AC

LE2'

- 1

0 3/

4" T

.O. W

AS

TE

PA

PE

R T

OW

EL

DIS

PE

NS

ER

3' -

10

3/4"

TO

BO

TT

OM

OF

MOUNT WITH OPERABLE PART OF DISPENSER @ 4'-0".

NOTE: PROVIDE BLOCKING AS REQUIRED FOR ALL TOILET ACCESSORY INSTALLATIONS

UNDERLAVATORY GUARD, 102800

LAVATORY SIDE ELEVATION

NOTE: ALL EXPOSED PIPES BELOW THE SINK OR COUNTERTOP SHALL BE INSULATED AND ALL SHARP OR ABRASIVE SURFACES SHALL BE REMOVED OR PROTECTED.

FLU

SH

VA

LVE

V.I.

F.

2' -

1"

HE

IGH

T O

F

NOTE: ENSURE HEIGHT OF FLUSH VALVE ACCOMMODATES PROPER INSTALLATION OF REAR GRAB BAR

OF

DIS

PE

NS

ER

1' -

7"

TO

OU

TLE

T

CL

CL

SURFACE MOUNTED PAPER TOWEL DISPENSER &

SURFACE MOUNTED WASTE RECEPTACLE

SOAPDISPENSER

NOTE: PLACE FLUSH VALVE ON WIDE SIDE OF STALL, RE: PLUMBING

4' -

0"

MOP AND BROOM HOLDER

OF 18" GRAB BAR

4

11

15

13

2

3

4

1

38

4

1

2

3

17

18

16

31

3' -

4"

FLU

SH

OM

ET

ER

2' -

6"

T.O

. FLU

SH

OM

ET

ER

V.I.

F. W

ITH

SU

BM

ITT

ED

1 1/

2" M

IN.

DO

WN

GR

AB

BA

R

2' -

11"

T.O

. SW

ING

GR

AB

BA

R2'

- 9

" T

.O. 3

6"

GR

AB

BA

R2'

- 9

" T

.O. 3

6" R

EA

R W

ALL

GR

AB

BA

R2'

- 1

1" T

.O. 4

2" S

IDE

WA

LL

CL

12"

2' - 0"1' - 0"

FLOOR MOUNTED TOILET PLAN

NOTE: 11" MAXIMUM REACH DEPTH FOR OPERABLE PORTION OF FAUCET17" MINIMUM DEPTH OF LAVATORY

13

38

NOTE: MOUNTING HEIGHTS INDICATED ON THIS SHEET SHALL GOVERN THROUGHOUT ENTIRE PROJECT, UNLESS SPECIFIC DIMENSIONS AND/OR REQUIREMENTS ARE PROVIDED/INDICATED WITHIN THE A SERIES OF DRAWINGS. COORDINATE INSTALLATION OF OWNER SUPPLIED ITEMS WITH MOUNTING HEIGHT DIAGRAM. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO INSTALLATION OR ROUGH-IN OF ANY ITEMS IN QUESTION.

CONTROL AND HAND SHOWER INSTALLATION ZONE

AUTOMATIC DOOR OPENER

RE: DOOR SCHEDULE

COORDINATE WITH CRASH RAILS

2' -

10"

UNDERMOUNT LAVATORY SINK PLAN

2' - 8 1/2"

2' -

6"

7

11

SOLID-SURFACE COUNTERTOP

REQUIRED KNEE AND TOE CLEARANCE

11" MIN.

6"

MIN

.9"

27"

MIN

.

8" MIN.

5' - 0" MIN.

CL16"-18"

6" 1

12"

3' -

4"

2

CL

EQ EQ

3

15

NOTE: ALL TOILET ACCESSORIES SHALL BE LOCATED WITHIN 48" OF TOILET

STANDARD ROLL IN SHOWER PLAN "GANGED SHOWER" LAYOUT

ROLL IN SHOWER WALL, WALL ELEVATION,

("BACK WALL" CONTROL WALL)

REFER TO SHEET A5.00 FOR FLOOR

PITCHING INFORMATION2'

- 6

" M

IN.

RE

FE

R T

O A

1.00

REFER TO A1.00

9

9

6" M

AX

.

1'-7

" M

AX

.

6" MAX.

LINEAR FLOOR DRAIN, RE: PLUMBING

2' -

7 1

/4"

C LS

HO

WE

R

CO

NT

RO

LS

3' -

2"

4' -

0"

2' -

9"

MIN

.

3' -

0"

MA

X

CL

ACCESSIBLE HAND SHOWER SYSTEM, RE: PLUMBING

OF CONTROLS AND WALL

EQ EQ

2' -

8"

2

6' -

8"

3' - 1"

"BACK WALL"

12 3

/8"

C LO

F

DR

AIN

EQ EQ

CLOF

SINK

R 1/2"

2' -

10"

MA

X.

6

OF

DIS

PE

NS

ER

1' -

7"

TO

OU

TLE

T

TOILET PAPER DISPENSER

2

13

3 1/

4"

5' -

0"

MIN

.

16" MIN.27" MAX

10

1' -

5"

NOTE: SHOWER HEAD AND CONTROLS SHALL HAVE THERMOSTAT THAT CONTROLS THE TEMPERATURE OF THE WATER TO BE 1200 MAX.

NOTE: COORDINATE TEMPERATURE CONTROL LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION.

("B

AC

K W

ALL

" C

ON

TR

OL

WA

LL)

1 1/2" MAX.

2 1/

2" M

AX

.

2'-6" X 5'-0" APPROACH ZONE

10

5' DIA. TURNING RADIUS, TYP.

2'-6" X 5'-0" CLEAR AREA

END WALL

1'-3

" M

IN.

1' -

4"

MA

X.

2

3' - 0" MAX.

PROVIDE BLOCKING IN WALL FOR FUTURE FOLD DOWN SEAT

+ - 3' - 0"

10 3/4"

3' - 6"3 1/

4"

1.0 EXISTING BUILDING (Chapter 34) 1.1 Continuation of Existing Use 1.2 Change of Use 1.3 Complying with International Existing Building Code

2.0 NEW BUILDING OR ADDITIONS 2.1 Exceeds Threshold Building Limits

6.0 MEANS OF EGRESS 6.1 Occupant Load by Floor

6.2 Total Occupant Load

7.0 FIRE RESISTANT RATING OF STRUCTURAL ELEMENTS (TABLE 602) 7.1 Structural Frame, including columns, girders, & trusses 7.2 Bearing Walls

7.2.1 Exterior (704) (not less than table 602)7.2.2 Interior

7.3 Non-bearing walls and partitions7.3.1 Exterior (704) (not less than table 602)7.3.2 Interior

7.4 Floor Construction including Supporting Beams & Joists (714)

7.5 Roof Construction Including Supporting Beams & Joists (714)

7.6 Fire Walls & Party Walls (Table 705.4)Note: An automatic sprinkler system is allowed to substitute for1 HR fire resistant construction per table 601

1.0 FIXTURE COUNTS (TABLE 403.1) Group I-1

malefemale

TOTALS

INTERNATIONAL PLUMBING CODE (ICC 2003)yesyesyes

nonono

N/AN/AN/A

XXX

yes no N/AX

3 stories 50 feet1 story 20 feet2 stories 15 feet COMPLIANT

8.0 FIRE PROTECTION SYSTEM 8.1 Fire Suppression System (Fully Sprinklered) (Existing) 8.2 Alarms 8.3 Automatic Fire Detection System 8.4 Smoke Control System 8.5 Supervision

occupant load2424

48

TOILETratios req.1/10 3 41/10 3 4

6 8

LAVATORYratios req.1/10 3 6 1/10 3 6

6 12

SHOWER/BATHTUBSratios 1/8 3 31/8 3 3

FOUNTAINratios req. 1/100 1 1 1/100 1 1

2 2

UTILITY SINKratios req.1 1

0

13.0 USE GROUP CLASSIFICATION (302.1) CASE 1 (Single use or non-separated mixed use) 3.1 Single Occupancies

4.0 HEIGHTS AND AREA COMPUTATION + CONSTRUCTION TYPE 4.1 Type of Construction Assumed for Review (602)

4.2 Building Height (tabular with allowable adjustments) 4.2.1 Allowable Building Height (Table 503):4.2.2 Height Modifications (504.2) Fully Sprinklered, ADD:4.2.3 Actual Building Height:

5.0 AREA COMPUTATION - (tabular with allowable adjustments) 5.1 Type of Construction Assumed for Review (602)

5.2 Allowable Tabular Floor Area (Table 503): 5.7 Actual Gross Floor Area

5.3 LARGEST Floor Area - Main Level

Lower Level Main Level14 33

47 occupants

provided provided req. provided

6 6

provided

7,541 s.f. COMPLIANT

Lower Level Main Level3,770 sf 7,541 sf

10,500 s.f. per floor

provided30

3

yesyesyesyesyes

nonononono

N/AN/AN/AN/AN/A

XXX

XX

STATE BUILDING CODE (IBC International Building Code 2012, as supplemented in 2016)

APPLICABLE CODES:- 2012 INTERNATIONAL BUILDING CODE, 2016 CONNECTICUT SUPPLEMENT- 2010 AMERICANS WITH DISABILITIES ACT AND ASSOCIATED GUIDELINES- 2009 ICC/ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES,

2016 CONNECTICUT SUPPLEMENT- 2012 INTERNATIONAL PLUMBING CODE, 2016 CONNECTICUT SUPPLEMENT- 2012 INTERNATIONAL MECHANICAL CODE, 2016 CONNECTICUT SUPPLEMENT- 2012 INTERNATIONAL ENERGY CONSERVATION CODE, 2016 CONNECTICUT SUPPLEMENT- 2014 NATIONAL ELECTRICAL CODE NFPA 70, 2016 CONNECTICUT SUPPLEMENT

- 2016 CONNECTICUT STATE FIRE SAFETY CODEPart I: ADMINISTRATIVE Part II: GENERALPart III: NEW CONSTRUCTION, RENOVATION, OR CHANGE

OF USE2012 INTERNATIONAL FIRE CODE

I-1 GROUP HOME

5A - COMBUSTIBLE, PROTECTED

5A - COMBUSTIBLE, PROTECTED

1 HR

1 HR

1 HR

0 HR

0 HR

1 HR

1 HR

N/A

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICESDIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.242 TRUMBULL STREET HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.17.2014 DD SUBMISSION

7.14.2017 FOR BIDDING

JULY 14, 2017

As indicated

TYPICAL MOUNTING HEIGHTSAND CLEARANCES, CODE INFO

G1.01

CDL

CAB

NOTE: ALL GANG OUTLETS SHALL BE VERTICALLY MOUNTED 18" A.F.F. AT DEVICE C.L.ALL GANG OUTLETS SHALL BE HORIZONTALLY MOUNTED AT 6"

9 TYPICAL MOUNTING HEIGHTSNTS

2 TYPICAL SURFACE HEIGHTSNTS

10TYPICAL MOUNTING HEIGHTS @ CORNER

CONDITIONNTS

5TYPICAL MOUNTING HEIGHTS IN A WALL

PANEL ASSEMBLYNTS

6TYPICAL MOUNTING HEIGHTS @ DOOR

WHEN OPENNTS

3TYPICAL MOUNTING HEIGHTS @ FIRE

PROTECTION EQUIPMENTNTS7

TYPICAL MOUNTING LOCATION @ DOOR

WHEN OPENNTS

KEYNOTE # TOILET ACCESSORY / PLUMBING FIXTURE

18 WASTE RECEPTACLE, 102800

19 NOT USED

20 NOT USED

21 NOT USED

22 NOT USED

23 NOT USED

24 NOT USED

25 NOT USED

26 NOT USED

27 NOT USED

28 NOT USED

29 NOT USED

30 NOT USED

31 MOP AND BROOM HOLDER, 102800

32 NOT USED

33 NOT USED

34 NOT USED

35 NOT USED

36 NOT USED

37 NOT USED

38 FLOOR MOUNTED TOILET, RE: PLUMBING

KEYNOTE # TOILET ACCESSORY / PLUMBING FIXTURE

1 36" LONG GRAB BAR, 102800

2 42" LONG GRAB BAR, 102800

3 18" TALL GRAB BAR, 102800

4 SWING-DOWN GRAB BAR, 102800.HORIZONTAL DISTANCE FROM CENTER OFSWING DOWN GRAB BAR TO CENTER OFTOILET SHALL MATCH DISTANCE OF SIDEGRAB BAR TO CENTER OF TOILET

5 5'-0" DIAMETER TURNING RADIUS AREA

6 4'-8" X 5'-0" CLEAR FLOOR AREA FORTOILET

7 2'-6" X 4'-0" CLEAR FLOOR AREA

8 ADA COMPLIANT UTILITY SINK, RE:PLUMBING

9 48" LONG GRAB BAR, 102800

10 FOLDING SEAT, N.I.C. (FUTURE)

11 UNDERMOUNT SINK IN COUNTER, RE:PLUMBING

12 NOT USED

13 TOILET PAPER DISPENSER, 102800.HORIZONTAL DISTANCE FROM CENTER OFDISPENSER TO FRONT OF TOILET TO BE7"-9"

14 NOT USED

15 EMERGENCY CALL FOR AID, RE:ELECTRICAL

16 SOAP DISPENSER, 102800

17 PAPER TOWEL DISPENSER, 102800

MOUNTING HEIGHT DIAGRAM

= OWNER SUPPLIED, CONTRACTOR INSTALLED*

CODE INFORMATION

1 TOILET ACCESSORY KEYNOTESNTS

Page 3: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 4: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 5: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 6: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 7: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

1

HOLLOW METAL DOOR FRAME

SEE DOOR SCHEDULE

SE

E D

OO

R S

CH

ED

ULE

A

SEE SCHEDULE

SE

E S

CH

ED

ULE

1-3/4" THK. FLUSH, SOLID CORE, PAINT GRADE WOOD

DOOR; PAINT TO MATCH ADJACENT GWB WALLS

B

SEE SCHEDULE

SE

E S

CH

ED

ULE

1-3/4" THK. FLUSH, SOLID CORE, PAINT GRADE WOOD

DOOR; PAINT TO MATCH ADJACENT GWB WALLS

2"

1/2" THROAT WIDTH 1/2"

2" 2"VARIES

F1

SCHEDULED CEILING

POPLAR CROWN MOULDING, BROSCO B-614 OR EQUAL

5/4 x 3 POPLAR FACE FRAME

1/2" BALTIC BIRCH PLYWOOD RECESSED PANEL

1X PAINTED POPLAR SHELF, TYP. OF 3

CONTINUOUS "U-SHAPED" ALUMINUM PILASTER, CLEAR ALUMINUM FINISH, TYP. (OUTWATER PRODUCTS SERIES 255 OR EQUAL) - ROUTE OUT PLYWOOD TO PROVIDE FLUSH INSTALLATION

3/4" BALTIC BIRCH PLYWOOD CABINET BOX (TOP, BOTTOM AND BACK) WITH DADO JOINTS

4 1/

4"1"

2 1/

2"2

1/2"

LINE OF 3/4" BALTIC BIRCH PLYWOOD CABINET BOX BEYOND

2' -

0"

1"

1' -

0"

1"1'

- 0

"2

1/2"

1 x POPLAR TRIM, TYP.

3/4" BALTIC PLYWOOD BOTTOM SHELF

5/4" PAINTED POPLAR CABINET SUPPORT BRACKET, BOTH SIDES

CONTINUOUS WOOD CLEAT, TYP. BACK AND SIDES -SECURE TO PARTITIONS AS NECESSARY

WALL FINISH AS SCHEDULED

1" THICK BALTIC PLYWOOD SHELF - LAMINATE 2 LAYERS OF 1/2" OR PROVIDE 1" THICK PANEL

NOTE: ALL COMPONENTS OF CABINET (PLYWOOD, POPLAR, ETC.) TO RECEIVE PAINT FINISH. PREPARE SURFACE AS NECESSARY FOR PAINT FINISH

RECESSED CLOCK OUTLET,RE: ELECTRICAL - TYP. EACH OPEN SHELF

ALI

GN

ALI

GN

8"

8"

1 1/4"

1 1/

4"

R 6 3

/4"

ALI

GN

1 X POPLAR

5 1/

2"

1"1' - 2"

1/2 SOLID SURFACE COUNTER ADHERED WITH SILICONE TO 3/4" CONTINUOUS

PARTICLEBOARD, TYP. 123623.13 - SCRIBE COUNTER TO WALL

WALL PARTITION AS SCHEDULED

FINISH FLOOR AS SCHEDULED

1/2" SOLID SURFACE BACKSPLASH, 123623.13

RETURN BACKSPLASH AND CLEAT WHEN COUNTER MEETS ADJACENT WALL, 123623.13

NOTE: ALL EXPOSED PIPES BELOW THE COUNTERTOP

SHALL BE INSULATED AND ALL SHARP OR ABRASIVE SURFACES

SHALL BE REMOVED OR PROTECTED

18"X36" SLANTED MIRROR WITH STAINED WOOD FRAME WITH

MITERED CORNERS

UNDERMOUNT SINK AND FAUCET AS SCHEDULED, RE: PLUMBING -

ADJUST SENSOR TO ACTIVATE WITHIN 11" OF COUNTER EDGE

NOTE: G.C. TO PROVIDE FIRE TREATED WOOD BLOCKING AS

REQUIRED FOR THE MOUNTING OF CABINETRY, COUNTERS, ETC. TYP.

MOTION ACTIVATING FAUCET, ACTIVATION TO OCCUR WITHIN 11"

OF COUNTER EDGE8"

2' -

3"

1' - 5"9"

6"

2" x 2" STEEL TUBE FULLY WELDED TO 3" X 3" STEEL TUBE IN WALL (2 BRACKET ASSEMBLIES PER SINK)

STAINED OAK WOOD END CAP TO MATCH FRAME

12A4.00

3' -

4"

MA

X. T

.O. R

EF

LEC

TIN

G S

UR

FA

CE

4 7/8" @ MIRROR

2 1/2"

2 ' - 11"

2 1/2"

2' - 6"

2' -

10"

CONTINUOUS FRENCH CLEAT

1 1/

4"2"

2' -

6 3

/4"

CLE

AR

2' -

10"

2"

1/2"

1/4"

3" X 9" X 1/8" STEEL PLATE ANCHORED TO CONCRETE SLAB W/ (4) 1/2" "DIA." EXPOXY BOLTS AT EACH POST

3" X 3" STEEL TUBE WITHIN WALL, WELDED TO STEEL BASE PLATE

4"

1/4"

1/4"

1/2" PLYWOOD BACKING

2" X 2" CONTINUOUS STEEL TUBE, FULLY WELDED TO STEEL BRACKET ASSEMBLIES

1/4"

CL DRAIN

8 3/8"

STAINED OAK WOOD END CAP AND MIRROR FRAME

3/4" PLYWOOD MIRROR BACKER

1/4" MIRROR GLASS

1X2 CONT. NAILER

3/4"

2 1/2"

FINISHED WALL SURFACE AS SCHEDULED

1"

1/2" PLYWOOD

JAMB ANCHOR, 081113 (4 PER JAMB)

PROVIDE CONT. SEALANT AROUND FRAME, 079200, BOTH SIDES OF DOOR

HM FRAME, 081113

SCHEDULED DOOR

EXISTING PARTITION TO REMAIN -MODIFY AS NECESSARY FOR NEW DOOR OPENING

(2) 2X WOOD STUDS - DEPTH TO MATCH EXISTING WALL CONSTRUCTION

1/2" TILE BACKING PANEL OVER EXISTING PARTITION, 093013. SECURE TO EXISTING PARTITION WITH LATEX PORTLAND CEMENT, 093000

CERAMIC TILE - TYPE AS INDICATED ON ELEVATIONS AND FINISH SCHEDULE ON LATEX PORTLAND CEMENT, 093000

1/8"

ALIGN

JAMB ANCHOR, 081113 (4 PER JAMB)

PROVIDE CONT. SEALANT AROUND FRAME, 079200, BOTH SIDES OF DOOR

HM FRAME, 081113

SCHEDULED DOOR

GYPSUM BOARD AS SCHEDULED IN PARTITION TYPES, 092900

2 (20) GAUGE MTL STUDS, 092216, AT JAMB (REPLACE STUDS WITH METAL RUNNER AT HEAD)

TILE BACKING PANELS, 093000

LATEX PORTLAND CEMENT MORTAR, 093000

CERAMIC TILE - TYPE AS INDICATED ON ELEVATIONS AND FINISH SCHEDULE, 093000

1/8"

ALIGN

JAMB ANCHOR, 081113 (4 PER JAMB)

PROVIDE CONT. SEALANT AROUND FRAME, 079200, BOTH SIDES OF DOOR

HM FRAME, 081113

SCHEDULED DOOR

2 (20) GAUGE MTL STUDS, 092216, AT JAMB (REPLACE STUDS WITH METAL RUNNER AT HEAD) - AT SIM. JAMB CONDITION PROVIDE (2) 2X WOOD STUDS TO MATCH EXISTING PARTITION - REFER TO DETAIL 3/A4.00 FOR ADDITIONAL NOTES

GYPSUM BOARD AS SCHEDULED, BOTH SIDES, 092900

NOTES

1 ALL NEW DOORS WITHIN SCOPE OF WORK AREA SHALL RECEIVEBUILDING STANDARD LEVER TYPE (ADA COMPLIANT) HARDWARE.FINISH TO MATCH EXISTING.

2 PAINT ALL WOOD DOORS - COLOR AS SELECTED BY ARCHITECT

REMARKS

A EXISTING DOOR TO REMAIN

B INDICATED DOOR WIDTH IS FOR (2) EQUAL DOORS

C DOOR IS INSTALLED INTO AN EXISTING PARTITION - VERIFYTHROAT DEPTH PRIOR TO SUBMITTING SHOP DRAWINGS

D PROVIDE POWER TO DOOR FOR DOOR OPERATION

HW SET (PER DOOR)

HW SET #11 PASSAGE FUNCTION LOCKSET MATCH EX. SARGENT1 DOOR OPERATOR 6010/6060 NORTON1 WALL SWITCH 531 NORTON1 PERIMETER GASKET S88 PEMKO4 SILENCERS 608/609 ROCKWOOD2 ARMOR PLATE K1062 48" 4BE CSK ROCKWOOD1 ELECTRIC STRIKE 9600 HES1 FLOOR/WALL STOP 404/440 ROCKWOOD4 HINGE (HEAVYWEIGHT) T4A3786 4-1/2" X 4-1/2" MCKINNEY

HW SET #21 CYLINDRICAL LOCK (STOREROOM) MATCH EX. SARGENT1 PERIMETER GASKET S88 PEMKO3 SILENCERS 608/609 ROCKWOOD2 ARMOR PLATE K1062 48" 4BE CSK ROCKWOOD1 FLOOR/WALL STOP 404/440 ROCKWOOD3 HINGE (HEAVYWEIGHT) T4A3786 4-1/2" X 4-1/2" MCKINNEY1 PERMANENT CORE 6300 X 4 KEYS SARGENT1 SURFACE CLOSER 351 PH10 SARGENT

HW SET #31 CYLINDRICAL LOCK (STOREROOM) MATCH EX. SARGENT1 PERIMETER GASKET S88 PEMKO3 SILENCERS 608/609 ROCKWOOD2 ARMOR PLATE K1062 48" 4BE CSK ROCKWOOD1 FLOOR/WALL STOP 404/440 ROCKWOOD6 HINGE (HEAVYWEIGHT) T4A3786 4-1/2" X 4-1/2" MCKINNEY2 FLUSH BOLT (@ INACTIVE LEAF) 555 ROCKWOOD1 DUST PROOF STRIKE 570 ROCKWOOD1 PERMANENT CORE 6300 X 4 KEYS SARGENT

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICESDIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.242 TRUMBULL STREET HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.17.2014 DD SUBMISSION

7.14.2017 FOR BIDDING

JULY 14, 2017

As indicated

DOOR SCHEDULE, DOORDETAILS, ELEVATIONS

A4.00

KDC

Approver

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

DOOR AND FRAME SCHEDULE

#

DOOR FRAME HEADDETAIL

JAMBDETAIL

SILLDETAIL

FIRERATING

HARDWARESET REMARKSWIDTH HEIGHT TYPE MATERIAL TYPE MATERIAL ELEVATION THROAT SIZE

102A 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 3/A4.00 (SIM) 3/A4.00 19/A5.00 - 1 C, D

102B 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 3/A4.00 (SIM) 3/A4.00 19/A5.00 - 1 C, D

103 4' - 0" 7' - 0" B HM F1 HM 1 0' - 5 1/8" 2/A4.00 (SIM) 2/A4.00 - 3 B

104 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 3/A4.00 (SIM) 3/A4.00 19/A5.00 - 1 C

105 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 7/A4.00 (SIM) 7/A4.00 (SIM) - - 2 C

120 3' - 0" 7' - 0" A HM F1 HM 1 0' - 5 1/8" 2/A4.00 (SIM) 2/A4.00 - 2

121 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 3/A4.00 (SIM) 3/A4.00 19/A5.00 - 1 C, D

122 3' - 6" 7' - 0" A HM F1 HM 1 0' - 4 7/8" 3/A4.00 (SIM) 3/A4.00 19/A5.00 - 1 C, D

E101 3' - 6" 7' - 0" EX EX EX EX EX EX EX EX EX EX A

SCALE: 1/4" = 1'-0"

DOOR AND FRAME TYPES LEGEND FRAME DETAILSSCALE: 1 1/2" = 1'-0"16 TYPICAL MILLWORK SECTION

SCALE: 1" = 1'-0"18 TYPICAL SECTION AT SINK

SCALE: 3" = 1'-0"12 MIRROR DETAIL

SCALE: 3" = 1'-0"3 HM JAMB DETAIL - TYPE E PARTITIONS

SCALE: 3" = 1'-0"2 HM JAMB DETAIL - TYPE U PARTITIONS

SCALE: 3" = 1'-0"7 HM JAMB DETAIL

DOOR & HARDWARE NOTES

elwellde
Typewritten Text
ADD-ALT 2
elwellde
Line
elwellde
Line
elwellde
Line
elwellde
Line
Page 8: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

CT-1

GWB-1

N/A

CT-3

CT-1

GWB-1

N/A

CT-3

PT-1

GWB-1

RB-1

CT-3

PT-2

GWB-1

RB-2

CT-3

REPAIR EXISTING WALL FINISH TO MATCH EXISTING ADJACENT AFTER

NEW DOOR INSTALLATION EX. VCT

CT-3

EX. VCT

CT-3

EX. VCT

CT-3

EXISTING

EXISTING

EXISTING

EXISTING

PROVIDE NEW / REPAIR EXISTING FINISH TO MATCH EXISTING ADJACENT,

TYP. FULL EXTENTS OF LINETYPE

EX

. VC

T

CT

-3

CT-2

GWB-1

N/A

CT-3

PT-1

GWB-1

RB-1

CT-3

CT-2

GWB-1

N/A

CT-3

PROVIDE NEW / REPAIR EXISTING FINISH TO MATCH EXISTING ADJACENT,

TYP. FULL EXTENTS OF LINETYPE

EX

. VC

T

CT

-3

EX

. VC

T

CT

-3

BATHING ROOM

101

PITCH TO DRAIN1:48

18A5.00

+1 1/4"

+0"

+0" +0" +0" +0"

+3/8"

+3/8"

+1 1/4"

+1 1/4"

PITCH TO DRAIN1:48

+1 1/4"

+3/8"

+3/8"

+1 1/4" +1 1/4"

18A5.00

MIR

UP

UP

1:48

MA

X.

1:48

MA

X.

CONTRACTOR SHALL COORDINATE FINAL HEIGHT OF TILE FLOOR TO ACCOMMODATE THE HEIGHT OF FLOOR TRENCH DRAIN

CE

ILIN

GW

AL

L

GWB-1 INTERIOR GYPSUM WALL BOARD CEILING - PAINTED (PT-1)

PT-1

PT-2

FIELD COLOR

ACCENT COLOR

RB-1 RUBBER BASE TO BE USED WITH PT-1

MARK DESCRIPTION

FINISH LEGEND

GENERAL NOTES

1. FRAMES TO BE PAINTED THE SAME COLOR AS WALL DOOR IS LOCATED ON, UNLESS OTHERWISE NOTED.

2. ALL DOORS (SCHEDULED TO BE PAINTED) TO BE PAINTED SAME COLOR AS WALL DOOR IS LOCATED ON.

3. REFER TO INTERIOR ELEVATIONS FOR WALL TILE PATTERN AND EXTENTS.

4. ALL WALLS TO BE PAINTED PT-1, UNLESS OTHERWISE NOTED.

5. CENTER ALL FLOOR TILE WITHIN ROOM UNLESS OTHERWISE NOTED.

6. ALL GYPSUM BOARD CEILINGS AND SOFFITS TO BE PT-1, UNLESS OTHERWISE NOTED.

7. PROVIDE BULLNOSE TILE MATCHING FIELD TILE AT ALL CERAMIC TILE OUTSIDE CORNER CONDITIONS.

8. PRIOR TO INSTALLATION OF ALL TILE / STONE PRODUCTS, TILE / STONE SUBCONTRACTOR TO CONFIRM LAYOUT WITH ARCHITECT.

9. ALL FINISHES SHALL BE APPLIED/INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONSAND/OR INSTRUCTIONS.

10. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE EXISTING CONDITIONS AND REPORT ANYDISCREPANCIES OR CONFLICTS TO THE ARCHITECT PRIOR TO BEGINNING INSTALLATION OF FINISH MATERIAL.

11. ENSURE THAT ALL WALL TILE IS INSTALLED WITH TRUE HORIZONTAL LINES. AT SLOPING FLOOR LOCATIONS, CUT TILETO MATCH SLOPE OF FLOOR TO MAINTAIN CONSISTENT JOINT THICKNESS BETWEEN WALL AND FLOOR, 1/4" MAX.

FINISH TAG

X

X

X

X

CEILING FINISH

WALL FINISH

BASE FINISH

FLOOR FINISH

RB-2 RUBBER BASE TO BE USED WITH PT-2

FINISH

FINISH

FINISH TRANSITION TAG

CT-1 CERAMIC TILE - 6" X 36" - MEN'S ROOMS

CT-2 CERAMIC TILE - 18" X 18" - WOMEN'S ROOMS

N/A NO BASE - CERAMIC WALL TILE EXTENDS TO FLOORBA

SE

CT-3 MOSAIC CERAMIC TILE - 3" X 3"

FL

OO

R

T.O.S.0' - 0"

EXISTING CONCRETE SLAB ON GRADE OR SLAB ON DECK TO REMAIN

1/4" / 12"

NEW SANITARY PIPING,RE: PLUMBING

CERAMIC TILE AS SCHEDULED ON THICKSET MORTAR BED, 093013. PITCH SETTING BED TO DRAIN

WATERPROOFING MEMBRANE, 093013

LINEAR FLOOR DRAIN, RE: PLUMBING

WATERPROOFING MEMBRANE - TYP. OF

LINETYPE, 093013

2" MIN. LAP

SHOWER SIDE

EXISTING VCT FLOORING TO REMAIN

FLEXIBLE SEALANT, 093013

WATERPROOF MEMBRANE/CRACK ISOLATION MEMBRANE BELOW ALL NEW TILE/THRESHOLD - TURN MEMBRANE UP AT THRESHOLD, 093013

TILE FLOORING ON THICKSET SETTING BED -PITCH UP AS PER PITCHING DIAGRAM

1/4"

1/4"

MARBLE THRESHOLD ON 1/8" SETTING BED, 093013

1/8"

(V

.I.F

.)

1" 1"PROVIDE CONTINUOUS SEALANT BETWEEN VCT AND

MARBLE THRESHOLD

ALIGN

BULLNOSE TILE AT SILL, JAMBS AND HEAD CONDITIONS, TYP.

DRAIN LEFT IN THE PROJECT FOR FUTURE POTENTIAL SHOWER LOCATION

EXISTING WINDOW

CONTINUOUS SEALANT AROUND PERIMETER

PRESSURE TREATED 2X WOOD BLOCKING

+1 1/4"

PIT

CH

TO

DR

AIN

1:48

PIT

CH

TO

DR

AIN

1:48

18A5.00

+0" +3/8"

+0" +3/8" +1 1/4"+1 1/4"

+1 1/4"

18A5.00

UP

UP

1:48 MAX.

1:48 MAX.

CONTRACTOR SHALL COORDINATE FINAL HEIGHT OF TILE FLOOR TO ACCOMMODATE THE HEIGHT OF THE FLOOR TRENCH DRAIN

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICESDIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.242 TRUMBULL STREET HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.17.2014 DD SUBMISSION

7.14.2017 FOR BIDDING

JULY 14, 2017

As indicated

FINISH PLAN AND SCHEDULE,FLOORING DETAILS

A5.00

Designer

Approver

SCALE: 1/4" = 1'-0"8 FIRST FLOOR FINISH PLAN OF MENS ROOM

SCALE: 1/4" = 1'-0"6 FIRST FLOOR FINISH PLAN OF WOMENS ROOM

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

SCALE: 1/4" = 1'-0"16 FLOOR PITCHING DIAGRAM - MEN'S ROOM

SCALE: 3" = 1'-0"18 DETAIL @ LINEAR FLOOR DRAIN

SCALE: 12" = 1'-0"19 TRANSITION @ EXISTING VCT TO NEW TILE

SCALE: 3" = 1'-0"17 DETAIL @ WINDOW SILL/GRAB BAR

SCALE: 1/4" = 1'-0"14 FLOOR PITCHING DIAGRAM - WOMENS ROOM

elwellde
Rectangle
elwellde
Line
elwellde
Line
elwellde
Line
elwellde
Typewritten Text
ADD-ALT 2
elwellde
Typewritten Text
ADD-ALT 2 ADD-ALT 2
Page 9: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 10: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces
Page 11: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

EXISTING JANITOR'S CLOSET

CLOSET120

WOMEN'S ROOM A121

WOMEN'S ROOM B122

BATHING ROOM101

MEN'S ROOM A102

CLOSET103

MEN'S ROOM B104

JANITOR'S CLOSET105

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014

DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

FLOOR PLANS

1/4"=1'-0"

SJH

ALO

M1.1

elwellde
Rectangle
elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2 ADD-ALT 2
elwellde
Typewritten Text
ADD-ALT 2
elwellde
Typewritten Text
ADD-ALT 2
Page 12: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014

DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

MECHANICAL SYMBOLS, LEGENDS

AND ABBREVIATIONS

N.T.S.

SJH

ALO

M2.1

Page 13: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014

DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

MECHANICAL DETAILS

N.T.S.

SJH

ALO

M2.2

Page 14: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014

DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

MECHANICAL SCHEDULES

AND DETAILS

N.T.S.

SJH

ALO

M3.1

elwellde
Typewritten Text
ADD-ALT 2
elwellde
Line
elwellde
Line
elwellde
Typewritten Text
ADD-ALT 2
elwellde
Line
Page 15: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

EXISTING JANITOR'S CLOSET

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

PER PLAN

ELECTRICAL DEMOLITION

FLOOR PLANS

ED1.1

LP

RR

elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2 ADD-ALT 2
Page 16: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

ELECTRICAL LEGEND

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

PER PLAN

ELECTRICAL SYMBOLS AND

NOTES

E0.0

LP

RR

Page 17: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

OF DOOR ANDOVERHEAD TRACKING

CL

OF DOOR ANDOVERHEAD TRACKING

CL

CLOSET120

WOMEN'S ROOM A121

WOMEN'S ROOM B122

BATHING ROOM101

MEN'S ROOM A102

CLOSET103

MEN'S ROOM B104

JANITOR'S CLOSET105

BATHING ROOM101

MEN'S ROOM A102

CLOSET103

MEN'S ROOM B104

JANITOR'S CLOSET105

OF DOOR ANDOVERHEAD TRACKING

CL

OF DOOR ANDOVERHEAD TRACKING

CL

CLOSET120

WOMEN'S ROOM A121

WOMEN'S ROOM B122

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

PER PLAN

ELECTRICAL FLOOR PLAN

E1.1

LP

RR

elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2ADD-ALT 2
Page 18: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

4'-0"

4'-0"

26'-0"

7'-11

31/32

"

OPEN TOBEYOND

OPEN TOBEYOND

OPEN CUBBIES

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

PER PLAN

ELECTRICAL DETAILS

E4.1

LP

RR

Page 19: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

E6.1

LP

RR

PER PLAN

ELECTRICAL POWER RISER

AND SCHEDULES

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014

DD SUBMISSION

July 14, 2017

07.14.2017FOR BIDDING

elwellde
Typewritten Text
Page 20: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

EXISTING JANITOR'S CLOSET

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

PARTIAL PLANS

PLUMBING DEMOLITION

1/4"=1'-0"

JRB

DM

PD1.0

elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2ADD-ALT 2
Page 21: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

ABBREVIATIONS PLUMBING PIPING SYMBOL LEGENDPLUMBING VALVE / FITTING SYMBOL LEGEND

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

PLUMBING ABBREVIATIONS,

SYMBOLS AND LEGEND

N.T.S.

JRB

DM

P0.1

Page 22: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

CL CLCL CL

OF DOOR ANDOVERHEAD TRACKING

CL

OF DOOR ANDOVERHEAD TRACKING

CL

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

PLUMBING PARTIAL PLANS

FIRST FLOOR

1/4"=1'-0"

JRB

DM

P1.0

elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2 ADD-ALT 2
Page 23: SHEET NUMBER ENLARGED PLAN / DETAIL IDENTIFICATION...Jul 16, 2019  · drawing revision / revision number a101 1 sheet number column grid tag accessible element clear floor spaces

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

OF DOOR ANDOVERHEADTRACKING

CL CL

BATHING ROOM101

MEN'S ROOM A102

CLOSET103

MEN'S ROOM B104

JANITOR'S CLOSET105

OF DOOR ANDOVERHEAD TRACKING

CL

OF DOOR ANDOVERHEAD TRACKING

CL

CLOSET120

WOMEN'S ROOM A121

WOMEN'S ROOM B122

drawing prepared by

drawing title

descriptiondatemark

R E V I S I O N S

IMPROVEMENTS TO 40 SHORE ROAD

BI-NN-665

WATERFORD, CONNECTICUT 06385

14052

AEA PROJECT No.

STATE OF CONNECTICUTDEPARTMENT OF CONSTRUCTION SERVICES

DIVISION OF CONSTRUCTION SERVICES

AMENTA|EMMA ARCHITECTS, P.C.

242 TRUMBULL STREET

HARTFORD CT, 06103

6.27.2014 SD SUBMISSION

project

CAD no. project no.

date

scale

drawn by

approved by

drawing no.

P:\14052.rvt

12.19.2014DD SUBMISSION

July 14, 2017

N

WOMEN'S ROOM

MEN'S ROOM

PORCH

07.14.2017FOR BIDDING

FIRE PROTECTION PLANS

1/4"= 1'-0"

GFL

RHR

FP1.1

elwellde
Rectangle
elwellde
Typewritten Text
ADD-ALT 2
elwellde
Typewritten Text
ADD-ALT 2ADD-ALT 2