Office Space Planning Guidelines
August 2012
![Page 2: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/2.jpg)
Assessment of Space Planning Principles
Office Space Planning Guidelines
What were the shortcomings of the former space planning?
High proportion of space assigned to individual work space, low proportion to shared work space and support spaceInflexibleDid not support informal collaboration and teamworkAccess to daylight and views were limited
![Page 3: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/3.jpg)
What We Have Done
Office Space Planning Guidelines
• Assessed user requirements• Appraised the planning potential of the Secretariat Building• Reviewed relevant best practice in public and private offices• Developed space planning guidelines
![Page 4: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/4.jpg)
Lessons From User Requirements
Office Space Planning Guidelines
Accommodate both interaction and individual concentrated work• Support the need for privacy• Deal with noise and distraction
Support high levels of collaborative work• More meeting spaces• More varied settings for meetings
Respond to users’ desire for change• Greater consistency of space allocation• Collocation is a higher priority than more individual space• Better paper handling and file storage• Present a fresh image for the UN – in space and its management• Improve environmental quality (air and temperature)• Better ergonomics and more comfort
![Page 5: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/5.jpg)
Pre-Renovation Typical Floor Plan
Office Space Planning Guidelines
Almost no perimeter open spaceLow level of shared spacesHigh level of individual spaceWasted double circulation
TV
DO
WN
UP
DOWN
UP
Interactive/support areas Enclosed officesOpen offices
N S
W
E
![Page 6: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/6.jpg)
Former Individual Workspace Guidelines
Office Space Planning Guidelines
UNITED NATIONS SPACE GUIDELINES AND TYPICAL LAYOUT
D-2 (336sqft)
D-1(i) (258sqft)
D-1(ii) (192sqft)
P-5 (144sqft)
P1-4 (96sqft)
G-PL (80sqft)
G-OL (48sqft)
USG/ASG (420sqft)
Many variations exist
![Page 7: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/7.jpg)
New Space Planning Design Principles
Office Space Planning Guidelines
• Provide more opportunity for team work/collegiality• Improve flexibility in space use• Allocate office space in a rationalized, simplified and streamlined
way• Realize organizational values of openness• Use daylight and views• Reduce wasted double circulation
![Page 8: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/8.jpg)
New Individual Workspace Guidelines, Compared To Former
Office Space Planning Guidelines
D-2 (336sqft)
D-1(i) (258sqft)
D-1(ii) (192sqft)
P-5 (144sqft)
P1-4 (96sqft)
G-PL (80sqft)
G-OL (48sqft)
Existing
New
Workstyle C Professionals
(96sqft)(Open)
Workstyle A USG/ASG (384sqft)
(Enclosed)
Workstyle B Directors (192sqft)(Enclosed)
Workstyle D General
Services (64sqft)(Open)
USG/ASG (420sqft)
![Page 9: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/9.jpg)
New Individual Workspace Guidelines
Office Space Planning Guidelines
Simplification of office size guidelinesImplement 4 work space types (compared to currently 8+types)
Work space sizes are multiples of each other, for easy reconfiguration
USG/ASG 24’X16’=384sqft Directors 12’X16’=192sqft
Professionals 12’X8’=96sqft General Services 8’X8’=64sqft
![Page 10: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/10.jpg)
New Shared Resources on Every Floor
Office Space Planning Guidelines
Resource Area Space Guideline 12’x16’ = 192 sqft
Arrival Point Space Guideline 8’x12’ = 96 sqft Visitors touchdown Space Guideline 8’ x 8’ = 64 sqft
Browsery Space Guideline 6’x8’ = 48 sqft
Focus Booths Space Guideline 4’x6’ = 24 sqft Pantry Space Guideline 2’x10’ = 20 sqft
Typical 8 seats per floorOne per floor
Typical 2 per floorTypical 3 per floor
Typical 3 per floor
![Page 11: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/11.jpg)
New Shared Meeting Spaces on Every Floor
Office Space Planning Guidelines
Small Meeting Room Space Guideline 8’x12’ = 96 sqft
Medium Meeting Room Space Guideline 12 x16’ =192 sqft
Open Informal Space Guideline 8’x8’ = 64 sqft
Soft Meeting Space Guideline 8’ x 8’ = 64 sqft
Large meeting rooms are consolidated on the 15th & 27th
elevator crossover floors
Typical 2 per floor
Typical 2 per floor
Typical 1 per floor
Typical 1 per floor
![Page 12: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/12.jpg)
New Meeting Room Plans, Floors 15 & 27
Office Space Planning Guidelines
Reception & Visitor Areawith Resource area, Pantry, Coat Closet
CombinableConference Rooms
Suite for short-term use
Breakout Areas
Access through twoElevator Banks Conference
RoomsTouchdownOffice Area
![Page 13: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/13.jpg)
Open vs. Closed Spaces
Office Space Planning Guidelines
Pre-renovation
Post-renovation
![Page 14: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/14.jpg)
Individual vs. Shared Spaces
Office Space Planning Guidelines
Pre-renovation
Post-renovationPlus shared meeting
room floors 15 and 27
![Page 15: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/15.jpg)
Circulation
Office Space Planning Guidelines
Pre-renovation• No controlled security access• Broken circulation pattern• Primary and secondary closed
floor circulation
Post-renovationOption for controlled security
accessNo division between departmentsFull loop around coreOpen floor circulation
Point of Access
![Page 16: Shared Space Planning Guidelines Update Aug12](https://reader034.fdocuments.net/reader034/viewer/2022042510/55cf8fe9550346703ba12c94/html5/thumbnails/16.jpg)
New Space Guidelines at Work in the Secretariat Building
Office Space Planning Guidelines
Professional workstationPantry
General Service workstation Professional workstation