International Conference TOWARDS NET ZERO ENERGY BUILDINGS Aalborg University (Sydhaven) , Copenhagen, Denmark Tuesday, April 30th, 2013 Session E : Lessons learned from NetZEB Annex 52 Case studies Recommended building solutions Michael Donn & François Garde Sub Task leaders / SubTask C IEA SHC Task 40 / ECBCS Annex 52 Towards Net Zero Energy Solar Buildings TASK 40/ANNEX 52

Transcript of Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency...

Page 1: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

International Conference TOWARDS NET ZERO ENERGY BUILDINGS

Aalborg University (Sydhaven) , Copenhagen, Denmark Tuesday, April 30th, 2013

Session E : Lessons learned from NetZEB Annex 52 Case studies Recommended building solutions

Michael Donn & François Garde Sub Task leaders / SubTask C IEA SHC Task 40 / ECBCS Annex 52 Towards Net Zero Energy Solar Buildings TASK 40/ANNEX 52

Page 2: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Who we are

Prof. François Garde - Director of Sustainable

Construction Department - ESIROI, Université de la

Réunion - Coordinator IEA NetZEB STC Dr Michael Donn - Victoria University SOAD - CBPR - Coordinator IEA NetZEB STC

http://moyakarta.ucoz.ru/rastr/anti-world-map.jpg

Latitude 40

Latitude 20

Page 3: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Net ZEB: What is going on ?

IEA Task 40/Annex 52 Towards Net Zero Solar Energy Buildings www.iea-shc.org/task40

Target : Joint international research to advance NZEB to practical reality in the marketplace. Subtask A: Definitions and Implication (Germany/Italy) Subtask B: Design process and tools (Canada) Subtask C: Development of solution sets for different climates, building types and functions (Reunion/FRA, NZ) Subtask D: Dissemination and Outreach (Canada)

7 mandatory criteria: 30 NZEB identified worldwide so far Web data base

Page 4: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

IEA Task 40/Annex 52 : 19 Countries involved Towards Net Solar Energy Buildings

Singapore

IEA – Task 40/Annex 52 : “Towards Net Zero Energy Solar Buildings” 19 countries involved 30 buildings Cooling Challenges;

Heating Challenges; Heating AND Cooling Challenges.

Page 5: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

International Conference TOWARDS NET ZERO ENERGY BUILDINGS

Aalborg University (Sydhaven) , Copenhagen, Denmark Tuesday, April 30th, 2013

Pixel Schiestk-Schutzhütte

Sundays Elithis Tower

Green Office

Kyoto Highschool Limeil Brevannes

Pantin primary school

IES Cargese

Page 6: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

ENERPOS Meridian

Daycare in Monheim

Prim. sch. in HohenNeuendorf

Lajon school

Ilet du centre

Solar XXI

CIrce

Marché international

Zero Energy Building at BCA

Page 7: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Plus Energy houses « weiz » EcoTerra

Riverdale

Plus energy settlement Kraftwerk

Leaf House Lima

Kleehauser

Energy Flex Family Riehen

Page 8: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

The netZEB balance concept

Igor Sartori , Assunta Napolitano , Karsten Voss

Energy and Buildings Volume 48 2012 220 - 232 http://dx.doi.org/10.1016/j.enbuild.2012.01.032

Page 9: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Monitored data vs design data – Non Res

Page 10: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Monitored data vs design data – Res

Page 11: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

11

Thermal comfort in hot conditions

• Two main principles: – Solar protection – Cross natural ventilation

Page 12: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Comfort approach Givoni zones of comfort

Page 13: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Building climate analysis

• Classify Temperature, Humidity, Solar, Daylight and Wind climates for the

use in generalising Solution Sets

• Initial study - traditional external climate classification did not

account for the non-residential building challenges.

Residential = Heating dominated

Non-Residential = Heating dominated

• Accounts for local climate and building standards

Page 14: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Climate Analysis

Page 15: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Site Context

What are solution sets ?

1. Building Challenge Solution Set - The set of solutions used to lower the energy needed by a particular building challenge.

2. Whole Building

Solution Set - The set of solutions used to lower the energy consumption of the whole building.

Design Hierarchy and Solution Sets

Page 16: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Many ‘Solutions’

Page 17: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Case Study - Enerpos

Page 18: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Passive design Solutions • Cross ventilated • Solar shading • Large windows for daylighting

Energy efficiency

Solutions • T5 lightings • Ceiling fans

Renewable Energy Solutions • PV (50 kWp)

ENERPOS on Reunion Island U-values

• Roof : 0,34 W/m2.K • Walls : 3,45 W/m2.K

Page 19: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

BiPV Roofs 370 m²/49 kWp

Page 20: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting
Page 21: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Monitoring - Energy use and production

• Energy use (Net Floor Area ; Final Energy) : 14 kWh/m².y

• Production (Net Floor Area ; Final Energy) : 78 kWh/m².y

Consumption is 10 times less than a standard university building in Reunion Island

• Max load: 8 W/m² 4 times less than a standard building

• Mismatch?

ENERPOS is net zero on an annual,

monthly and daily scale

Page 22: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Comfort approach

Maximum allowable indoor temperature with natural ventilation and ceiling fans => 30°C

100% 97% 92% 93% 90% 93% 77% 45%

Comfort > 80% Comfort < 80%

Page 23: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

POE - User feedback

Page 24: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

6 case studies

Canada to Brisbane Denmark to Reunion Island Melbourne to Oslo Lisbon to Santiago Wellington to Roma Reunion Isl. to Christchurch

Solution set identification – Performance Sketch: major design ideas? – Change Climate – new solution set(s)?

Givoni Comfort Analysis – BEES template based EnergyPlus models

Performance Sketch Energy Analysis – BEES template based EnergyPlus models

Page 25: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

PIXEL in Melbourne

Page 26: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Passive measures • Cooling:

• Green Roof • Solar shading • Natural Ventilation • Tinted glass

• Heating:

• Heat recovery ventilator

• Daylight systems:

• Exterior fixed solar shading

The BUILDING

Page 27: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Energy efficiency measures

• Artificial Lighting: 3 W/m2

• Computer Network: 4.2 W/m2

• Plug load: 10 W/m2

• Hydronic in-slab pipework in chilled ceilling

The BUILDING

Page 28: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Energy Generation

• PV

• Wind

The BUILDING

Page 29: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

PIXEL in Oslo

Melbourne

Oslo

Page 30: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

SOUTH

PV Wind Turbines

NORTH

Glazing

Shading

Night cooling

Insulation

Lighting Power Density & controls

STPV

Orientation

Ventilation

PIXEL in Oslo

Page 31: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Passive solutions - Re-orient - No night cooling - Double glazing - Shade transparency - Insulation - Natural ventilation EES - Increase lighting power density - Lighting controls RES - PV on the roof - Semi-transparent PV for the shading Estimated NZEB

Page 32: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Overheating

0

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40 45

Hum

idity ratio (g water/kg dry air)

Temperature (°C)

Page 33: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

With natural ventilation (in summer)

Page 34: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Energyflex : overall picture

Location : Copenhagen, Denmark 2 buildings with different activities JUST 1 BUILDING STUDIED: family house – 4 people! Net floor area per building: 216m² Ground floor: bedrooms – 1st floor: living spaces

Page 35: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Energyflex : original solutions set

• Passive design techniques • Volume to surface ratio: 0.55 [1/m] compact! • High insulation:

average Uopaque = 0.1 [W/m²K] Uglazed = 0.75 [W/m²K]

• Energy efficiency technologies • Floor heating coupled with ground source heat pump • Mechanical ventilation with heat recovery and coupled with heat

pump

• Renewable enegy technologies • Fixed photovoltaics • Solar thermal domestic hot water

Page 36: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Location change

Copenhagen, Denmark

St Pierre, La Réunion

Page 37: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Climatic conditions Outdoor temperature

Copenhagen, Denmark St Pierre, La Réunion

Heating dominated Cooling dominated

Page 38: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Not so much comfort in 1m/s zone…we have to go to 2m/s! HIGHER NATURAL VENTILATION AND CEILING FANS!

BASE CASE from DENMARK To REUNION ISLAND

% of comfort (0 m/s) 13%

% of comfort (1 m/s) 56%

Hrs of discomf. (0m/s) 7579 h

Hrs of discomf. (1m/s) 3824 h

Base case : La Reunion

Page 39: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Energyflex Family in Reunion New solutions set

• Cross natural ventilation, high porosity, • Ceiling fans • Large shading • High insulation of the roof (maintained) • Low thermal mass and low insulation of the

walls • No double glazing, louvres. Change of the pattern but not the shape of the building (life outside!)

Page 40: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Conclusions Recommended building solutions

• NZEB are narrow buildings for daylighting and cross ventilation

• Air-conditioning can be avoided

• Crucial role of ceiling fans (even for cold climates)

• Comfort, comfort, comfort

• Integration of the role of the users at the early design stage

Page 41: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Lessons Learned • Aim of Lessons Learned:

– Understand the issues related to the design and technologies of the net zero energy building method

• Interviewed design teams • 7 of the 30 Cases examined:

– Non-residential – Office and Education

• IDP – essential

• Energy Performance must be early goal

• Hierarchy when designing Net ZEBs : Passive Design → Energy Efficiency Systems → Renewable Energy Solutions.

• Energy end-use: office equipment 50%.

• Ceiling fans, instead of active cooling 18-30°C comfort band works in any climate when coupled with natural ventilation and ceiling fans

Page 42: Session E : Lessons learned from NetZEB Annex 52 Case ... · - Double glazing - Shade transparency - Insulation - Natural ventilation . EES - Increase lighting power density - Lighting

Ceiling fans Green Office - Paris