Server : Installs Server and Client on one PC only (Setup...
-
Upload
nguyenquynh -
Category
Documents
-
view
242 -
download
4
Transcript of Server : Installs Server and Client on one PC only (Setup...
Server : Installs Server and Client on one PC only (Setup.exe)Communications Modules : USB Drivers and utilities Documents : All manuals in PDF formatClient : Installs Client (Setup.exe)Firmware: Various Firmware FilesUpdate: Service packs (if needed)Adobe Acrobat Reader Included on DVD
TIP: To configure the IP address of the RBH-UNC100-XXX use the ‘Device Discovery’ tool built into the Integra32 software. Install the Integra32 software… Login…go to tools menu… select ‘Device Discovery’ . Choose the proper network card and select search… any controllers on the network segment will be displayed. Select the desired controller and edit….enter the IP address and select ok. The default password is ‘password’.
License : Feature KeyWeb : Web Server InstallerDVR : Integration PacksFingerprint : Integration Packs
THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILSProcessor: Intel Core 2 Duo or betterMemory: 1-2 GB depending on OSStorage: 20 GB, or more if neededDVD-ROM, Ethernet Port, USB portsOperating System: WindowsEditions: Pro, Business, Ultimate 32 Bit: Windows 7, 8, Server 2003, 2008 64 Bit: 7, 8, Server 2008
Integra32
ServerUNC100
Static LAN IP AddressRequired for UNC
Static Internet IPAddress for Router
Router on siteBroadband Modem
CAT5 (300’ Max.)
Port Forwarding - Configure Router to forward designated IP port on Internet IP address (as entered in Integra32) to a port on Local Network (UNC100). Example: In Integra32 software set 5.6.23.7 port 75. On remote router forward remote site port 75 on 5.6.23.7 to UNC100 on port 3002 on 192.168.1.125
CAT5
RBH does not provide tech support on port forwarding!
Internet
PC to Router to Internet to Router to Controller
INTE
RNET
CONT
ROLL
ER W
ITH
LAN
GATE
WAY
- UN
C100
OVER
VIEW
DVD
CONT
ENTS
PC S
PEC
Note1 : Remove paper from Lithium battery when installing Note2 : If using standby battery on UNC100 DC voltage in must be 13.5 to 13.8 volts to properly charge the standby battery
TX: Flashing = RS485 NormalRX: Controllers 2 thru 15 online
RUN: Flashing = Normal
HOST: Flashing Red = Host is PollingFlashing Green = Controller replyFlashing red and Green = Normal
TROUBLE: Off = Normal
UNC100
Panel2
Panel16
Panel Network # 1
Panel Network # 32RS-485 BusUp to 4,000’
LAN / WAN /INTERNET
Client # 2
Client # 10
Integra32
Server
Up to 9 simultaneous clients: Up to 32 simultaneous connections to Server (panel networks) Only ONE Server!
Thin and Web clients are available for Internet connectionsUp to 64 doors (32 x 2-door panels or 16 x 4-door panels) per Integra32 Server
Up to 32 doors (16 x 2-door panels or 8 x 4-door panels) per Panel Network
Client # 3
(Includes 1 client)Panel2
Panel16
UNC100Panel Network # 2
LAN / WAN /INTERNET
JP3 on Circuit Board
IN
POWER
OUT
Address SW1 SW2 SW3 SW4
1 X O O O
2 O X O O
3 X X O O
4 O O X O
5 X O X O
6 O X X O
7 X X X O
8 O O O X
9 X O O X
10 O X O X
11 X X O X
12 O O X X
13 X O X X
14 O X X X
15 X X X X
Denotes 12vdc in or 12vdc out when using POE
A. UNC100 and PC are on the same subnet:UNC : XXX.XXX.ZZZ.AAA PC : XXX.XXX.ZZZ.BBBTo configure UNC100 type in it’s address into web browser.
B. UNC100 and PC are on the same net, different subnets:UNC: XXX.XXX.ZZZ.AAA PC : XXX.XXX.YYY.BBBUse IPLocator to detect UNC100 and change it’s IP address, go to A
C. UNC100 and PC are on different nets and/or subnets:Manually set your PCs IP address to match net/subnet of the UNC100, go to A to configure UNC100.
OUTP
UTS
RTE : to keep door unlocked we need re-triggering of RTE input (Each trigger extends unlock timer)
DC : N.O. sensors are wired in parallel, N.C. sensors in series
Wiring : Up tp 1,000’ on 18-22 AWG 2-Cond. cable
SUPP
ORT
READ
ERS
INPU
TSAC
CESS
POI
NTS
For Support Call : 201-663-9070 / Option 1
Web site : www.rbh-access.comE-mail : [email protected]
RTEInstalled
DCInstalled
Lock by timer
Lockon door close
Door Forced
Door Held Open
Yes Yes Yes Yes Yes YesNo Yes Yes Yes No* YesNo No Yes No No No
RTE : Request to Exit, typically motion detector, crash bar, exit button - Shunts door contact and unlocks door for exitDC : Door Contact (a.k.a. door switch, DSM) - Monitors whetherthe door is opened or closedReader : Card, Fingerprint Reader with/or keypad with Wiegand Interface - Reads user credentials, PINs, etc.Lock : Electric strike, lock set, magnetic lock or any electrically actuated device - secures an access pointAccess Point : Door, gate, turnstile, any point with secured access
RTE
R
DC
L
AccessPoint
* Will activate every time door is opened to exit, you can turn “Disable Door Forced Open” feature on
“ON State”Setting
OperationType
“Output Off”Relay is:
“Output On” Relay is:
N.O.Mark
N.C. Mark
Energized Fail-Secure Off On N.O. N.C.
De-energized Fail-Safe On Off N.C.* N.O.*
Lock
* Functionality of relay polls will be reversed vs. printed marking
Relay Outputs (Marked #N.O./#N.C./#C): Maximum rating 5A @ 30V, Dry, Form “C” relay
Voltage Outputs (Marked #OC) : 100mA, -12VDC, for solid state devices only (LED, Piezo, etc.)N.O.N.C. COC
+
+ -12V 0V
LED
Marking
INSTALL DIODE on DC powered locks! 1N4007 Diode installed at the lock will prevent damage to the controller. Please, use MOVs (metal oxide varistors) for AC powered locks.
Diode 1N4007White stripe to +
NO LOCKS! on OC outputs
Supervision type
Detects state changes:
Supervised secure
Supervised in alarm
None Yes No No.1 Resistor Yes Yes No2 Resistor Yes Yes Yes
MarkingCircuit Type: Normally Closed Normally Open N. C. 1 Resistor N. O. 1 Resistor N. C. 2 Resistors N. O. 2 Resistors N. C. & N.O. 1 Resistor
Open Alarm Restore Alarm Trouble Trouble Trouble TroubleShort Restore Alarm Trouble Alarm Trouble Trouble Alarm
1K N/A N/A Restore Restore Restore Alarm Restore2K N/A N/A N/A N/A Alarm Restore N/A
Circuit State Default
1K Resistor Color code: Brown Black Red / Gold: 5% tolerance
Complete database is stored on the Server PC, cards and settings are transferred to the
panel during the download. Panel retains this data and operates independently, sending
events to Server and receiving commands from it. It is not possible to “upload” hardware
configuration or card database from the panel. Please configure Integra32 Server’s built in backup function to preserve your data in case of PC failure!
Function RBH HID AWID TerminalLED Brown Orange Brown GRN
Buzzer Blue Yellow Yellow BUZData 0 Green Green Green D0Data 1 White White White D1
Ground Black Black Black 0VPower Red Red Red 12V
Reader LED StatusRed Locked
Green Unlocked
Blinking “High Security” Mode
Reader Sounder EventLong Beep Access Granted
Two Short Beeps Access DeniedFour Beeps Mode Changed
Beeping DHO Warning or PIN request
Continuously On Door Forced or Door Held Open Alarm
See reader manual for actual color codes!
RED GRN BUZ D0 D1 0V 12V
To EXIT Reader
GRN RED BUZ D0 D1 SIG 0V 12V
To ENTRY Reader
To Controller
RBH-EXITRDR
EXITRDR : This module allows reporting of direction on doors
with readers installed on both sides, while using a single
reader port on the controller (RBH reader wiring shown)
Wiring : Up to 500’ Max from Reader to Panel on 18 AWG 6-Cond. Shielded Cable
THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS
NOTE
S
-