Series 3800 Shower Assembly - Lawler Manufacturing Company
Transcript of Series 3800 Shower Assembly - Lawler Manufacturing Company
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS3 hand spray and DV1 diverter valve.
Series 3800 Shower AssemblyENG. NO. 3800-1-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
6 "OPTIONAL
N.P.T. TEMPERED OUTLET
1 "2
6 "
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS1 hand spray, DV1 diverter valve and TF2 diverter tub filler.
Series 3800 Shower AssemblyENG. NO.3800-2-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
6 "OPTIONAL
N.P.T. TEMPERED OUTLET
1 "2
6 "
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblySeries 3800 thermostatic mixing valve, SC1 straight stop and checks and SH6 shower head.
ENG. NO. 3800-3-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblySeries 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, HS3 hand spray, TH5 dial thermometer, DV1 diverter valve and TF2 diverter tub filler.
ENG. NO. 3800-4-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
6 "OPTIONAL
N.P.T. TEMPERED OUTLET
1 "2
6 "
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblySeries 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange and TH5 dial thermometer.
ENG. NO. 3800-5-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblySeries 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange and TF2 diverter tub filler.
ENG. NO. 3800-6-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblySeries 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, TH5 dial thermometer, VC3 concealed volume control and TF2 diverter tub filler.
ENG. NO. 3800-7-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower AssemblyENG. NO. 3800-8-A
Series 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, VC3 concealed volume control and TF2 diverter tub filler.
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
Series 3800 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks, SH1 shower head, arm and flange, and VC3 concealed volume control.
ENG. NO. 3800-9-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
Series 3800 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks and SH1 shower head, arm and flange.
ENG. NO. 3800-10-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
Series 3800 Shower AssemblyIf the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks and HS3 hand spray.
ENG. NO. 3800-11-A
48 "
FLOOR LINE
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
28 "
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
ENG. NO. 3800-12-A
Series 3800 thermostatic mixing valve, SC1 straight stop and checks and HS3 hand spray and TF2 diverter tub filler.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 Shower Assembly
48 "
FLOOR LINE
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
N.P.T. TEMPERED OUTLET
1 "2
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1
28 "
DATA SHEET
www.lawlervalve.com
5330 East 25th StreetIndianapolis, Indiana 46218
Phone (317) 261-1212Fax (317) 261-1208 Design and specification subject to change without notice.
If the angle stop and checks with removable strainers are required, see ENG 3800 A for details.
Series 3800 thermostatic mixing valve, SC1 straight stop and checks, SH6 institutional shower head, HS1 hand spray and DV1 diverter valve.
Series 3800 Shower AssemblyENG. NO.3800-13-A
48 "
FLOOR LINE
28 "
1 "2
N.P.T.HOT
INLET
N.P.T.COLDINLET
1 "2
13 "4
3 1"2
9 1"2
FINISHEDWALL
6 "OPTIONAL
N.P.T. TEMPERED OUTLET
1 "2
6 "
WARM COLD
HOT SHUT
1 "2
2
N.P.T.TEMPEREDOUTLET
1 "2
ALL PIPING N.P.T.1 "2
MIN.
MAX.
HOLE IN WALL7 " DIA.
3 "4
13 "4
1