Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility...
Transcript of Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility...
![Page 1: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/1.jpg)
1
Ser[LOG] System
© Reveuse absolue - fotolia.de
Ser[LOG] Benefit from the expandability of the data logger Ser[LOG] and its modules and create your customized measuring station. For professional recording and processing of your meteorological data. This brochure will guide you through the possible combinations.
![Page 2: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/2.jpg)
2
MeteoWare_CS _3 Client
Revision: 01.11.2016 © 2015,2016 LAMBRECHT meteo GmbH MW_CS_3_Client_Manual.doc Page 34 of 53
Graph with 4 quarter screens, each with a sensor. Here the curves for the measurement series temperature PT100, relative humidity, air pressure and precipitation can be seen. Each curve has its own Y axis. The value display on the auxiliary line, at the mouse cursor, is shown for every curve.
+ 3 x
+ 2 x
Phot
os: ©
appl
er-,
©Ls
hop-
Foto
lia.c
om
22.1
7
Expansion possibilities
Das Ser[LOG] SystemAlmost unlimited possibilities with the Ser[LOG] system family! Up to 3 AnDiMod can be connected to the data logger Ser[LOG] and up to 2 AnDiMod measuring modules can be connected to the data logger Ser[LOG]Plus. You will recive 36 analog/ 11 digital inputs. In addition there are virtuals channels which can be defined by existing formula collection, e. g. dew point calculation, air pressure reduction or by freely definable formula ► A maximum of 60 channels are supported. Numerous state-of-the-art communication channels are available (Bluetooth, GSM, FTP, e-mail, SMS, Modbus-RTU, Modbus-TCP, SDI-12 etc.). The configuration is easily done with the app "Ser[LOG] Commander".
In the extraction, provision, analysis, visualization and archiving of large amounts of data the Lambrecht app "MeteoWare CS3" supports you.
Data logger Ser[LOG] for serial sensors• 6 serial interfaces (1 x configurable as SDI-12)• 2 digital status inputs• 2 potential-free relays (status inputs for recording states)
Analog/Digital Measuring Module AnDiModfor the expansion of Ser[LOG] and Ser[LOG]Plus. With RS485 bus for further analog modules. Each measuring module contains: • 12 analoge differential channels• 3 digital channels• 6 connections for the power supply of the sensors
Data logger Ser[LOG]Pluscombined Ser[LOG] + AnDiMod in one device. • 12 analog interfaces • 6 serial interfaces (1x interface assigned to AnDiMod ·
with RS485 bus for up to 2 x AnDiMod)
![Page 3: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/3.jpg)
3
Precipitation Humidity/Temperature Air Pressure Global RadiationWind
Flexible design · outstanding versatilityMany LAMBRECHT sensors are available for the composition of your individual system solution. We have summarized the selection criteria for you in an overview. So you can easily defy the growing challenges of your daily measurement tasks.
Connectable sensors
LAMBRECHT-sensor Parameter
Ser[LOG]Plus
ID 00.95770.100 000
Ser[LOG]
ID 00.95770.100 000
AnDiMod
ID 00.95770.100000
interfaces
u[sonic] Wind serial
EOLOS-IND Weather serial
com[b] Wind serial
PREOS Wind serial
ARCO-SERIAL Wind serial
WENTO-IND Weather serial
rain[e] Serie Precioitation serial
8126 X81. Air pressure serial
8095 THP series Temp./Humidity/Air pressure
serial
16103Global radiation serial/ analog
INDUSTRY Wind analog
PRO-WEA Wind analog
15189 Precipitation analog
8093.11 Temp./Humidity
analog
8121 Air pressure analog
16106Global radition analog
© Galyna Andrushko © Jan Will © Daniel Gustavsson © Lulu Berlu © ivan kmit - Fotolia.com
![Page 4: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/4.jpg)
4
One for allSer[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom for individual adjustments to your measuring tasks: • extensibility due to modular design• high flexibility due to a multitude of configuration options• many possibilities due to state-of-the-art communication interfaces Take a look at the technical data of the connectable sensors and create your individual system solution.
Serial sensors
Combined Ultrasonic Wind Sensor u[sonic] Id-No. 00.16470.000000
Measurement range: Wind direction: 0...359,9° • Wind speed: 0...75 m/s
Range of application: -40...+70 °C (with heating -50...+70 °C) • 0...100 % r. h.Accuracy: Wind direction: < 2° (> 1 m/s) RMSE • Wind speed: ± 0.2 m/s RMSE (v < 10 m/s) • ± 2 % RMSE (10 m/s < v < 65 m/s)
Static Wind Sensor com[b] Id-No. 00.16441.004112
Measurement range: Wind direction: 0...360° • Wind speed: 0.1...50 m/s
Range of application: -40...+70 °C • 100 m/s • 0...100 % r. F.
Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value
Static Weather Sensor EOLOS-IND/H Id-No. 00.16430.000002 unheated • 00.16430.010002 heated
Measurement range: Wind direction: 0...360° • Wind speed: 0.1...85 m/s • Air temperature: -40...+70 °C • Relative humidity: 0...100 % r. h. • Air pressure: 600...1100 hPa
Range of application: -30...+70 °C (unheated · under non-icing conditions) • -40...+70 °C (heated) • 0...100 m/s • 0...100 % r. F. Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value • Air temperature: ± 0.8 °C (v > 2 m/s) • Relative humidity: ± 3 % (10...90 %) • ± 4 % (0...100 %) • Air pressure: ± 2 hPa (-40...+85 °C) · ± 0.5 hPa at 25 °C
Static Wind Sensor PREOSId-No. 00.16440.014002
Measurement range: Wind direction: 0...360° • Wind speed: 0.1...65 m/s
Range of application: -40...+70 °C heated • 0...100 m/s • 0...100 % r. h.
Accuracy: Wind direction: ± 3° • Wind speed: ± 0.5 m/s ± 5 % of the meas. value
![Page 5: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/5.jpg)
5
Combined Wind Sensor ARCO-SERIALId-No. 00.14581.010010
Measurement range: Wind direction: 0...360° • Wind speed: 0.3 ... 75 m/sRange of application: -30...+70 °C (unheated · under non-icing conditions) • 0...80 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 2 % FS at 0.3 ... 50 m/s
Combined Weather Sensor WENTO-IND Id-No. 00.14516.210001
Measurement range: Wind direction: 0...360° • Wind speed: 0.3...75 m/s • Relative humidity: 0...100 % r. F. • Air pressure: 600...1100 hPa • Air temperature: -30...+70 °C
Range of application: -30...+70 °C heated • 0...80 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 2 % FS at 0.3...50 m/s • Relative humidity: ± 3 % (10...90 %); ± 4 % (0...100 %) • Air pressure: ± 2 hPa (-30...+70 °C) • Air temperature: ± 0.8 °C
PRO ModbusId-No. 00.14523.130030 • 00.14524.100030
Measurement range: Wind direction: 0...360° • Wind speed: 0.5...75 m/s
Range of application: -40...+70 °C (heated) • 0...100 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 1° • Wind speed: ± 0.3 m/s ≤ 10 m/s • ± 0.5 m/s in the range of 10...60 m/s
Weighing Precipitation Sensor rain[e]Id-No. 00.15184.000000 unheated • 00.15184.400000 heated
Measurement range: 0…20 mm/min resp. 0…1200 mm/h
Range of application: 0...+70 °C (unheated) • -40...+70 °C (heated · no icing, no snowdrift)Accuracy: ± 0.1 mm/min resp. ± 6 mm/h
Weighing Precipitation Sensor rain[e]H3Id-No. 00.15184.540020
Measurement range: 0…20 mm/min or rather 0…1200 mm/hRange of application: -40...+70 °C (no icing, no snow blowing)Accuracy: ± 0.1 mm/min or rather ± 6 mm/h
![Page 6: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/6.jpg)
6
Combined Sensor THP (8095)Id-No. 00.08095.000000
Measurement range: Temperature: -40...+70 °C • Relative humidity: 0...100 % r.h. • Barometric pressure: 500...1100 hPaAccuracy: Temperature: ± 0.3 °C at (v > 2 m/s) · ± 0.4 °C (10…40 °C) · ± 0.8 °C (-10…+70 °C) • Relative humidity: ± 3 % (10...90 %) r. h. · ± 4 % (0...100 %) r. h. • Barometric pressure: ± 2 hPa (-30...+70 °C) ± 1 hPa (-10...+60 °C)
Combined Sensor THP (8095-NAV) with membrane filter for special resistance to air pollutantsId-No. 00.08095.001000
Measurement range: Temperature: -40...+70 °C • Relative humidity: 0...100 % r.h. • Barometric pressure: 500...1100 hPaAccuracy: Temperature: ± 0.3 °C at (v > 2 m/s) · ± 0.4 °C (10…40 °C) · ± 0.8 °C (-10…+70 °C) • Relative humidity: ± 3 % (10...90 %) r. h. · ± 4 % (0...100 %) r. h. • Barometric pressure: ± 2 hPa (-30...+70 °C) ± 1 hPa (-10...+60 °C)
Pyranometer (16103) 'Second class'Id-No. 00.16103.500060
Measurement range: 0...1600 W/m2
Range of application: -40...+80 °CISO classification: Second classWMO performance level: Moderate quality
Air pressure sensor 8126 X81Id-No. 00.08126.481002
Measurement range: 35...2000 hPa
Range of application: -45...+85 °C during operation
Accuracy: ± 0.0144 % FS
Serial sensors
Pyranometer (16131.5-Modbus) 'First class'Id-No. 00.16131.501030
Measurement range: 0...3000 W/m2
Range of application: -40...+80 °CISO classification: First classWMO performance level: Good quality
![Page 7: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/7.jpg)
7
Wind Sensor INDUSTRY · incl. cableId-No. 00.14567.100180 Wind direction • 00.14577.100 180 Wind speed
Measurement range: Wind direction: 0...360° • Wind speed: 0.7...50 m/s
Range of application: -30...+70 °C (heated) • 0...60 m/sAccuracy: Wind direction: ± 2° • Wind speed: < ± 2 % FS
Wind Sensor PRO-WEA · incl. cableId-No. 00.14523.130080 Wind direction • 00.14524.100080 Wind speed
Measurement range: Wind direction: 0...360° • Wind speed: 0.5...60 m/s
Range of application: -40...+70 °C heated • max. gusts 100 m/s • 0...100 % r. h.Accuracy: Wind direction: ± 2° • Wind speed: ± 0.3 m/s ≤ 10 m/s • ± 0.5 m/s...60 m/s
Serial sensors
Analog sensors
Precipitation Sensor (15189)Id-No. 00.15189.002000 · 2 cm³ volume of tipping bucket · unheated 00.15189.402000 · 2 cm³ volume of tipping bucket · heated 00.15189.004000 · 4 cm³ volume of tipping bucket · unheated 00.15189.404000 · 4 cm³ volume of tipping bucket · heated
Measurement range: 2 cm³: 0...8 mm/min • 4 cm³: 0...16 mm/minRange of application: 0…+70 °C metering (unheated · frost resistant down to -20 °C) • -20...+70 °C (heated · no icing, no snowdrift)Accuracy: ± 2 % with intensity correction
Pyranometer (16130.5-Modbus) 'Secondary standard'Id-No. 00.16130.501030
Measurement range: 0...3000 W/m2
Range of application: -40...+80 °CISO classification: Secondary standardWMO performance level: High quality
![Page 8: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/8.jpg)
8
Pyranometer (16103) 'Second class'Ident-Nr. 00.16103.500060
Measurement range: 0...1600 W/m2
Range of application: -40...+80 °CCalibration uncertainty: < 1.8 % (k = 2)
Pyranometer (16106) · incl. cableId-No. 00.16106.000080
Measurement range: 0...1400 W/m2
Range of application: -40...+60 °CCosine error: < 10 % @ 80°
Air Pressure Sensor (8121) · incl. cableId-No. 00.08121.100002
Measurement range: 600...1100 hPa • switchable to 800...1100 hPaRange of application: Altitudes 0...4000 m • Temperatures -20...+70 °C • Humidity 0...99 % r. h. Accuracy: ± 1 hPa within the range of -10...+60 °C • < ± 2 hPa within the range of -20...-10 °C
Temperature Humidity Sensor (8093.11) · incl. cableId-No. 00.08093.110000
Measurement range: Temperature: -40...+60 °C • Relative humidity: 0...100 % r. h.
Range of application: Temperature: -40...+80 °C • Humidity: 0...100 % r. h.
Accuracy: Temperature: ± 0,2 °C at -27...+70 °C · Plus: ± 0.007 °C/ °C at: < +10 °C • > + 40 °C • Relative humidity: ± 2 % r.h. at: 5...95 % r. h. • +10...+40 °C · Plus: < 0.1 % r. h./ °C at: < +10 °C • > +40 °C
Analog sensors
Air Pressure Sensor (8128) ·Id-No. 00.08128.085072 • 00.08128.095072
Measurement range: 600...1100 hPa • 800...1100 hPaRange of application: Heights 0...3200 m • Temperatures -40...+60 °CAccuracy: ± 0,5 hPa in the range of 600...1100 hPa • ± 0,3 hPa in the range of 800...1100 hPa
![Page 9: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/9.jpg)
9
Accessories listIn the overview you will find the standard accessories you need to complete your individual weather station. We are also happy to realise your individual wishes. Just get in touch with us.
Name Id-No.. Image
Voltage supply
Mains adapter 60 W, with casing 00.14966.300000
Mains adapter 150 W, with casing 00.14966.200000
Mains adapter 240 W, with casing 00.14966.500000
Mains adapter 480 W, with casing 00.14966.600000
Kommunication and software
MeteoWare CS3 - Standard 36.09340.000000 without image
MeteoWare CS3 - Network 36.09340.100000 without image
MeteoWare CS3 - Network plus 36.09340.110000 without image
MeteoWare CS3 - Station plus 36.09340.200000 without image
Kabel
Cable for u[sonic] 10 m 32.16461.060000
Cable for EOLOS, WENTO (signal + supply) 10 m 32.16420.066100
Cable for ARCO (signal + supply) 10 m 32.14581.060000
Cable for rain[e] (signal + supply) 10 m 32.15184.060000
Additional cable for rain[e] heated, 1 m 32.15184.061000
Cable for 15189 (signal) 7 m 32.15188.060090
Additional cable for 15189 heated, 1 m 32.15188.061020
Cable for sensor THP, Modbus sensors 32.14567.060010
Installation
Aluminium tripod mast ( three-legged) 2.5 mTransport length: 1,45 m · useful length: 2.50 mPipe-Ø: 55/50 mm (Peak Ø: 50 mm) · pipe wall thickness: 2 mmaccessories included:· 3 ground spikes· Fastening material for housing 380 x 380 mm· Weight: approx. 7 kg
00.14627.000000
Aluminium telescopic mast, 3 mPeak-Ø: 50 mm
00.14627.030000 ohne Abb.
Wall bracket set, 150 mm, für 3 m aluminium telescopic mast 32.14627.030100
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
1A4
Wandhalterung
Status Änderungen Datum Name
Gezeichnet
Kontrolliert
Norm
Datum Name20.03.2014 Schönfelder
Mechanische Systeme LehmannDorfstrasse 3302629 Gnaschwitzwww. teleskopmast.de
Maßstab 1:2
Werkstoff: ALMg3
100.800110.0003a Znr. ergänzt 31.08.16 TE
Abwicklung 1:5
40
150
120°
120°
6
520,8
15140
220
345
20
8,5
2x
360
106
40
2x 11
33 33
60°
3-leg tripod base for 3 m aluminium telescopic mast 32.14627.030200
![Page 10: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/10.jpg)
10
750 mm outrigger for precipitation sensor, for 3 m aluminium telescopic mast, Ø 60 mm
32.14627.030300
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
1 A2
750mm Halbauslegerfür Niederschlagssensor 15189
100.900200.0104Status Änderungen Datum Name
Gezeichnet
Kontrolliert
Norm
Datum Name31.08.2016 Eckert
55
Klemmbacke KB55-V100.800400.0006-V
KD60 mitInbusschraube
115
Rohr Ø60x2 300lang
Rohr Ø55x2 700lang
Fuß Ø100, 15dick
750
Aluwinkel 40x40x5
770
Stainless steel mast (earth foundation) · for separate installation of precipitation sensors 15189 and rain[e] Pipe-Ø: 60 mm · Length: 1200 mm
00.15180.400000
Mast bracket for adapter 32.14966.030000
Wei
terg
abe
sow
ie V
ervi
elfä
ltigu
ng d
iese
r U
nter
lage
, Ver
wer
tung
und
Mitt
eilu
ng ih
res
Inha
lts n
icht
ge
stat
tet,
sow
ie n
icht
aus
dück
lich
zuge
stan
den.
Zuw
ider
hand
lung
ver
pflic
hten
zu
Scha
dens
ersa
tz.
Alle
Rec
hte
für
den
Fall
der
Pate
nter
teilu
ng o
der
Geb
rauc
hsm
uste
r-Ei
ntra
gung
vor
beha
lten.
Pass
ing
on a
nd d
uplic
atio
n of
thi
s do
cum
ent,
util
izat
ion
and
com
mun
icat
ion
ofit'
s co
nten
ts p
rohi
bite
d un
less
def
inite
ly p
erm
itted
. Inf
ringe
men
t is
bou
nd t
oco
mpe
nsat
ion.
All
right
s re
serv
ed fo
r pa
tent
or
regi
ster
ed p
atte
rn.
Zust. Änderungen Datum Name Dateiname Ersatz für:
Blatt
Bl
Bearb.Gepr.
Datum Name
Artikelnummer
Benennung
32.14966.030000.idw
1 / 1
20.01.2016 Krell
32.14966.030000
Masthalterung Cube
1 A4
Norm.
Revision
Bemerkung / Bestell-Nr.BenennungSach-Nr.Anz.Pos. Halteplatte33.14966.03000011 Unterlegscheibe 6,4 DIN 125 A A435.01251.60064142 Sechskantschraube M6 x 20 DIN 933 A235.09331.53380043 Sechskantmutter M6 DIN 934 A235.09341.50060044 Fächerscheibe 6,4 DIN 6798 A A435.67981.60064145je 60 cmSpannband69.61010.21000026 Spannschloss69.61010.21010027
Baugruppe wird nicht vormontiert
Weather-resistant sheet steel housing, suitable for installation of the Ser[LOG] series as well as power supply and communication unitDimensions: 380 x 380 x 210 mm
32.95666.030000
Mast bracket for sheet steel housing 32.95666.032000
Sensor shelter · Weather and radiation protection with natural ventilationtemperature operating range: -40...+70 °CNumber of lamellas: 11 piecesDimensions: Ø = 120 mm High = 300 mm (incl. mount)For mast diameter: 25...50 mmWeight: 950 gIncluded in delivery: Screw fitting for sensor-Ø 14...21 mm
00.08141.600000
Sensor shelter · Weather and radiation protection with artificial ventilationtemperature operating range: -40...+70 °CNumber of lamellas: 15 piecesDimensions: Ø = 150 mm High = 395 mm (incl. mount)For mast diameter: 25...50 mmWeight: 1.400 gIncluded in delivery: Screw fitting for sensor-Ø 14...21 mm
00.08141.600004
![Page 11: Ser LOG - LAMBRECHT · 2019. 3. 1. · 4 One for all Ser[LOG] stands for outstanding versatility and performance. The Ser[LOG] system family gives you the greatest possible freedom](https://reader036.fdocuments.net/reader036/viewer/2022070211/60fc9c79807c2c0f8969e3bb/html5/thumbnails/11.jpg)
11
You wish to tell us something or have a question?
Your contact person:Daniel DreilichTel: +49 551 [email protected]
LAMBRECHT meteo GmbH Friedländer Weg 65-6737085 Göttingen
Tel: +49 551 4958-0 www.lambrecht.net
Weather and radiation protection shelter 8141.6 TSfor traverse system
00.08141.610000
Set wind traverse consisting of:· 1 x 33.14627.001010 Traverse 750 mm· 1 x 32.14627.007000 · 1 x 32.14627.007000 2x Cover cap· 2 x 32.14627.002000 Holder parts WIND· 1 x 32.14627.001000 Mast bracket
32.14627.010000
Set traverse for pyranometer and TH consisting of:· 1 x 33.14627.001000 Traverse 1000 mm· 1 x 32.14627.007000 2x Cover cap· 1 x 32.14627.002000 Holder parts WIND· 1 x 32.14627.003000 Holder parts RADIATION· 1 x 32.14627.004010 Holder parts SENSOR SHELTER· 1 x 32.14627.001000 Mast bracket
32.14627.011000
Set Traverse for pyranometer and sensor shelter TS consisting of:· 1 x 33.14627.001000 Traverse 1000 mm· 1 x 32.14627.007000 2x Cover cap· 1 x 32.14627.003000 Holder parts RADIATION· 1 x 32.14627.001000 Mast bracket
32.14627.011010
Other accessoriesLightning rod 32.14565.019000
1 2 3 4
Fächerscheibe Mutter
Blitzschutzstab
Masthalterung
Bohrung B5 oder B6
B4B3
B6
B1 B2
B5
Mast Ø
InstallationsanweisungBlitzschutzstab
Technische Änderungen vorbehalten
Benötigtes Werkzeug ■ Ring-/Maulschlüssel oder Steckschlüssel o SW17 Mutter (Blitzschutz)
Da die Montage i. d. R. in großen Höhen statt ndet, muss das Montagepersonal bei der Installation die betreffenden Sicherheitsbestimmungen beachten.
Installieren des Blitzschutzstabes
32.14565.019000 Blitzschutzstab 1 Blitzschutzstab2 Fächerscheiben 10,42 Muttern M10
Beispiel: Montage der Blitzschutzstange an der MasthalterungDie Bohrungen B5 und B6 der Masthalterung 32.14627.001000 sind für die Montage einer opti-onalen Blitzschutzstange vorgesehen. Siehe auch "Installationsanweisung Traversen-System".
LAMBRECHT meteo GmbH Tel +49-(0)551-4958-0Friedländer Weg 65-67 Fax +49-(0)551-4958-31237085 Göttingen E-Mail [email protected] Internet www.lambrecht.net
14.16Quality System certified by DQS according toDIN EN ISO 9001:2008 Reg. No. 003748 QM08
WiFi router 00.90251.000000 (not illustrated)
Ground terminal block 4 x 3 32.14966.015000 (not illustrated)
Bracket for mast (for wind sensors INDUSTRY and PRO-WEA) 32.14627.001010 (not illustrated)
Micro SD card 8 GB (-25...+85 °C) · industrial standard 32.95800.010000 (not illustrated)
Wall bracket THP (indoor) 32.14629.010000 (not illustrated)Technische Änderungen vorbehaltenLAMBRECHT meteo GmbH Tel +49-(0)551-4958-0
Friedlaender Weg 65-67 Fax +49-(0)551-4958-31237085 Goettingen E-Mail [email protected]
Traversensystem 14627
25.15
Set Windtraverse32.14627.010000bestehend aus:1x 33.14627.001010 Traverse 750 mm1x 32.14627.007000 Set Abdeckkappen2x 32.14627.002000 Set Sensorhalterung, rund D301x 32.14627.001000 Set Masthalterung
Set Traverse für Pyranometer und TH32.14627.011000bestehend aus:1x 33.14627.001000 Set Traverse 1000 mm1x 32.14627.007000 Set Abdeckkappen1x 32.14627.002000 Set Sensorhalterung, rund D301x 32.14627.003000 Set Sensorhalterung, groß1x 32.14627.004010 Set Befestigungszapfen 100mm.1x 32.14627.001000 Set Masthalterung
Set Traverse für Pyranometer und Wetterhütte TS32.14627.011010bestehend aus:1x 33.14627.001000 Set Traverse 1000 mm1x 32.14627.007000 Set Abdeckkappen1x 32.14627.003000 Set Sensorhalterung, groß1x 32.14627.001000 Set Masthalterung
3-Bein-Teleskopmast 2,5 m Aluminium00.14627.000000