Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics –...

21
Sensus Radio Solutions

Transcript of Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics –...

Page 1: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

Sensus Radio Solutions

Page 2: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

2  

§  End Point with The Following Characteristics –  Static remanent magnetic field technology

–  R800, DN15 - DN40

–  IP68,T50, 90 bar

–  Composite material

–  Simple installation

–  For any quality of water

–  Embedded radio communication

–  Alarms and data logging

–  15 year battery life

iPERL

Page 3: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

3  

Sensus Radio Evolution – Walk By Drive By

IP  Network  

SIRT  (  Sensus  Installa+on  Radio  Tool  )  

Windows  /  Android    Handheld  

MDM  /  Billing    System  

Sensus  End  Points  

Page 4: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

4  

§  SIRT* with multiple antenna for best in class

radio performance

WalkBy

4  

SIRT*  Sensus  Interface  Radio  Tool  

Page 5: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

5  

Drive By Performance

*  

*Line  of  Sight  (LoS)  without  obstacles  

Page 6: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

6  

Sensus Radio Evolution – Fixed Radio

IP  Network  

Gateway    

Repeaters  

SIRT  (  Sensus  Installa+on  Radio  Tool  )  

Windows  /  Android    Handheld  

MDM  /  Billing    System  

Sensus  End  Points  

Page 7: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

7  

SensusRF in Fixed Radio Network

7  

Page 8: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

8  

SensusRF Gateway & Repeaters

8  

SensusRF  Gateway  and  up  to  7  stages  of    repeaters  enable  to  extend  the  radio  range    

Ø  Scheduled  reading  of  programmed  meters  Ø  Transparent  mode  Ø  Remote  reading  and  network  maintenance  Ø  Self  Healing  network  -­‐  using  alternaSve  path  Ø  GPRS  and  Ethernet  connecSon  Ø  100mW  (868MHz)  Ø  IP65  (raining  environment,  outdoor  usage)  Ø  Main  Power  Supply,  Solar  Panel  Ø  Uses  HTTPS  for  high  data  security  level  Ø  Immediate  alarm  fucSonaliSes  

Page 9: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

9  

Sensus Radio Evolution- Long Range Radio

IP  Network  

Gateway    

Repeaters  

FlexNet  LRR  

SIRT  (  Sensus  Installa+on  Radio  Tool  )  

Windows  /  Android    Handheld  

MDM  /  Billing    System  

Sensus  End  Points  

Page 10: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

10  

FlexNet – Long Range Radio •  FlexNet  –  Radio  network  enabling  smart  energy  &  resource  management  

•  One  network:  –  Smart  Metering  

•  Electric  •  Gas  •  Water  

–  Smart  Grid  

–  Smart  CiSes  

–  Demand  Management  

Page 11: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

11  

•  250MHz to 1,000MHz spectrum provide excellent balance between coverage, capacity and building penetration; making high meter connectivity economically viable

• Rapid roll-out of coverage

Radio Spectrum Considerations

FREQUENCY  SPECTRUM  

5  GHz  250  -­‐  1,000  MHz  60  MHz  

Capacity    

Coverage

 

100Km  

10Km  

1Km  

High  

Medium  

Excellent  

Building  PenetraRon  

Coverage/penetraRon  vs  Capacity  

Page 12: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

12  

FlexNet Range •  FlexNet  provides  excepRonal  coverage  to  all  end-­‐points  in  all  areas:  

–  End  point  locaSons:  indoors,  outdoors,  water  pits  

–  Environment:  dense  urban,  urban,  suburban,  rural  

•  FlexNet  uses  advanced  modulaRon,  dedicated  spectrum    

•  Typical  coverage  areas:  

–  Urbanised  areas  circa  2Km  up  to  5Km  range  

–  Rural  areas  circa  10Km  up  to  20Km  range  

FlexNet  (2–5  Km)  

Mesh  /  Low  Power  Radio  (<  500m)  

Cellular  (1-­‐2  Km)  

Page 13: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

13  

Macro Diversity

Base  StaRon  A  

•  All  Base  StaRons  are  always  listening  for  all  end  points  

•  Networks  are  designed  with  overlapping  cell  edge  coverage  

•  Redundancy  and  resiliency  from  day  one  

–  No  need  to  wait  for  surrounding  end-­‐points  to  be  installed  as  required  for  mesh  based  soluSons  

Base  StaRon  B  

Base  StaRon  C  

Page 14: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

14  

Licensed  Spectrum  versus  Unlicensed  Spectrum:  Scalability  and    Latency  handling  

Mesh Network Point to Multipoint Network

Multiple Prioritized Channels One Shared Channel

UNE  82326  

Page 15: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

15  

Fixed Radio Benefits

Customer  Service  Impact  

Reduced  Energy  ConsumpSon  

More  Efficient  Leakage  Management  

Recovered  Revenue  From  Faulty  Meters  

Improved  ForecasSng  Data  

Deferred  Capital  Expenditure  

ReputaSon  Management  

Value  Added  Services  

Reduced  LiabiliSes  to  3rd  ParSes  

Carbon  ReducSon  

Benefits   DefiniSons  

OperaSonal  Benefits  

AddiSonal  Benefits  

Regulatory  Benefits  

 Reduced  cost  of  dealing  with  customer  contact,  due  to  detailed  and  regular  informaSon  and  ability  to  answer  enquiries  quickly.    Reduced  energy  and  treatment  costs  from  decreased  water  demand  from  households  and  reduced  leakage    

 Reduced  network  and  customer  supply  pipe  leakage  management  costs    

 Increased  revenue  from  more  efficient  idenSficaSon  of  faulty  meters      Demand  forecasSng  and  security  of  supply  resilience,  short  and  long  term    Deferred  capital  investment  in  new  water  supply  infrastructure  as  a  result  of  water  demand  reducSon      Avoided  costs  and  revenue  opportuniSes  from  more  effecSve  reputaSon  management  with  customers  and  regulator      Revenue  from  providing  a  non-­‐core  services  such  as  a  monitoring  service  for  social  care  in  the  home,  or  reduce  household  insurance  costs.      Reduced  liabiliSes  to  regulator  for  fines,  and  potenSal  substanSal  legal  liabiliSes  from  backflow  incidents      Reduced  carbon  from  reduced  hot  water  heaSng  in  the  home  and  reduced  travelling  for  meter  reading    

Page 16: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

Case Studies

Page 17: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

17  

Great  Britain  contract  details  

Approx.  50%  of    UK  coverage  area  

Technology    

Region    

EsRmated                          Contract  Value  

Deployment  Scale  

Long  Range  Radio    technology  by  Sensus  operaRng  over  Arqiva’s  licensed  400MHz  band        

Northern  England  and  Scotland  113,255km²  (43,726miles²)    Represents  around  half  the  coverage  area  of  the  UK  programme  

 £625m  ($969m)        UK  Government  contract  over  15  years            

16  million  electric  and  gas  meters  to  be  connected  to  the  FlexNet  network  10  million    homes  and  small  businesses  

Page 18: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

18  

Great  Britain  Project  Details  

Technology    

Region    

EsRmated                          Contract  Value  

Deployment  Scale  

Long  Range  Radio    technology  by  Sensus  operaRng  over  Arqiva’s  licensed  400MHz  band    

The  Thames  Valley  13,000  Square  Kilometres              

 To  Be  Announced            

9  million  water  meters  to  be  connected  to  the  FlexNet  network.      

Page 19: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

19  

Canada  –  City  of  Barrie  Project  Details  

Technology   Region  Deployment  Scale  

Long  Range  Radio    technology  by  Sensus      

 PopulaRon  132,00  78  Square  Kilometres      

45,000  water  meters  connected  to  the  FlexNet  network.  

Page 20: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar

20  

Utility Grade Performance

Customer Terrain Area km2 End

Points Actually

Connected

Power Stream Dense Urban 800 325,000 99.1%

NVE (Nevada Electric)

Dense Urban & Sparse rural 141,154 800,000 99.2%

PGE (Portland General)

Dense Urban & Mountainous Rural 10,360 800,000 99.2%

Southern Company All terrains present 317,000 3,937,000 99.5%

Page 21: Sensus Radio Solutions - Energia Media · 2! End Point with The Following Characteristics – Static remanent magnetic field technology – R800, DN15 - DN40 – IP68,T50, 90 bar