6
Seegene NIMBUS IVD Efficient one-step process from nucleic acid extraction to PCR setup

Transcript of Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies...

Page 1: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

6541

-EN

1906

26B-

01

Seegene

NIMBUS IVDEfficient one-step process from nucleic acid extraction to PCR setup

Page 2: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

Seegene NIMBUS IVD is an easy-to-use liquid handling workstation from primary sample tube to nucleic acid(NA) extraction and PCR setup. It provides convenient process of your lab works by minimizing hands-on time and maximizing assay reliability.

Seegene’s automated MDx platform

Suitable for high-throughput

Traceability from sample to resultusing barcode system

Reliable performance & minimal hands-on time

Automatic process from primary sample tube to NA extraction and PCR setup

Simultaneous extraction of multiple specimen types

Convenient operation program

Ready-to-use reagent cartridge

Accepts multiple primaryand secondary vial types

Real-time PCRCFX96 DX from

NA extraction to PCR setup

One-step process

Specimens

- Whole Blood- Serum- Plasma- Cells- Urine

- LBC (Liquid based cytology) specimen- Swabs (Nasopharyngeal, Vaginal, Cervical, Urethral Rectal)- Aspirate (Nasopharyngeal)- BAL (Bronchoalveolar lavage)- Sputum

- Stool- Cary-Blair- CSF

96 X 4 Universal Cartridge Kit

Wash Bu�er 3Universal

WB353 mL

LOT

Elution Bu�erUniversal

EB15 mL

LOT

Lysis Bu�erUniversal

LB22 mL

LOT

Binding Bu�erUniversal

BB

WARNING

63 mLLOT

Wash Bu�er 1Universal

WB1

WARNING

53 mLLOT

Wash Bu�er 2Universal

WB2

9 mL

□ Before use, add 44 mL Ethanol to obtain 53 mL Wash Bu�er 2.

LOT

Universal Cartridge Kit

NIMBUS IVD

NIMBUS IVDSeegene

Page 3: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

HPV

Ready-to-use reagent cartridge system • Predispensed extraction reagents for up to 96 samples in one, re-useable cartridge• Eliminate hands-on time for reagent preparation• Verify reagent volume by barcode system

Maximizing workflow efficiency • Multiple specimen types and assays run at the same time • Open system for laboratory developed tests

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

Simultaneous nucleic acid extraction of multiple specimen types • Single set of reagent for extraction of bacterial, viral, genomic, parasitic, fungal DNA and/or RNA from multiple specimen types• Enhanced efficiency of working hours by reducing sample process time

Simultaneous extraction for multiple assays

- Urine-Genital swab

- Nasopharyngeal swab- Aspirate- Sputum / BAL

- Stool

- Liquid based cytology- Cervical swab

HPV Assay

STI Assay

RV/RBAssay

GIAssay

HPV STI RV/RB GI

NIMBUS IVD

<Time>

HPV STI RV/RB GI

STI

RV/RB

GI

SAVE TIME SAVE COST SAVE LABOR

Other systems

Seegene'sSystem

Seegene NIMBUS IVD

Page 4: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

* HAMILTON’s innovative technologies applied to NIMBUS IVD

HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology attaches disposable tips using a highly robust lock-and-key style mechanism. This enables improving a positional precision and eliminating mechanical stress and minimizing the production of aerosols. And air displacement pipetting system similar to high precision hand-held electronic pipettors can reduce risk of contamination or sample dilution. Anti-Droplet Control (ADC) technology can control pressure changes of liquid channels in real-time. Upon activation, ADC prevents inadvertent dripping from the channels, reducing the risk of contaminating the deck.

Extraction of maximum 72 samples depending on primary sample rack (option) • Optional use of 40 or 72 samples• Maximize sample capacity and throughput by replacing primary sample rack [5 x 12] with [5 x 18]

Option 1 (40 samples)5 x 12 primary sample rack

Option 2 (72 samples)5 x 18 primary sample rack

Convenient operation using ‘Seegene Launcher’ program • Intuitive tutorial session for each step of entire process• Easy integration of sample information by barcode scanner or LIS• Convenient to trace remaining reagent volume by barcode system• One click away to run various assays

Seegene NIMBUS IVD

Page 5: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

One-step process from NA extraction to PCR setup(can be used for PCR setup only) • Maximize user convenience by minimizing hands-on time• Selectable functions : entire process from NA extraction to PCR setup, extraction only, and PCR setup only• Reduction of risks for contamination and human error

Extraction Other equipment

PCR setupNIMBUSIVD

Catcher

Pitcher

DPO™ primer Target

Pitcher

5’

5’

5’

3’ 3’

3’

Tagging portion

R Q

3’

3’ 3’

5’5’

R3’

3’ 5’5’

Q

5’

3’

QR

3’ 5’

Non-target site

No extension No extension

Non-target site

When separate extraction instruments are already set up, it can be exclusively used for PCR Setup.

All in One platform for broad multiplex MDx assays • One platform to cover various disease area• Cost-effective to utilize one provider for all solution

* In development

RVFluRSV

...

GINoroRota

H. pylori..

TBMDRXDR

.

..

RBBPCP

.

..

STICTNG

.

..

SNPThrombosis

Thalassemia*...

All in One Platform

HPVHPV16HPV18

...Meningitis

HSV 1CMV

.

..

HAICPEVREESBL.

.

NIMBUS IVDAutomated NA extraction & PCR setup

CFX96 DXDetection by Real-time PCR

Seegene ViewerAutomated data analysis

Seegene NIMBUS IVD

Page 6: Seegene NIMBUS IVD - Triolab€¦ · Seegene NIMBUS IVD * HAMILTON’s innovative technologies applied to NIMBUS IVD HAMILTON’s proprietary CO-RE(Compressed O-Ring Expansion) technology

6541

-EN

1906

26B-

01

Not Available for Sale in the United States

• ORDERING INFORMATION

Category Products Cat. No.

Instrument

CFX96 DXOptical Reaction Module 1845097-IVD

Thermal Cycler 1841000-IVD

Seegene NIMBUS IVD 65415-03

Seegene STARlet IVD 67930-03

Extraction reagent STARMag 96 x 4 Universal Cartridge Kit 744300.4.UC384

Consumable

High Volume Tips(1000㎕) 235905

Standard Volume Tips(300 ㎕) 235903

NIMBUS-Waste Bag 65803-01

NIMBUS-96 Deep Well Micro Plate 67930-03

Independent liquid channels 4 ea

CO-RE gripper arm for labware movements 1 set

Sample rack (selection) : Sample rack for 32 samplesSample rack for [5 x 12]Sample rack for [5 x 18]

2 ea1 ea1 ea

Tip racks 4 ea

Magnetic separater 1 ea

Heater/Shaker (up to 100 °C) 1 ea

PCR plate rack 1 ea

Extraction cartridge rack 2 ea

PCR reagent rack 1 ea

UV Lights 2 ea

• COMPONENT

Power input 100-240 VAC, 50-60 Hz, 5 A

Power consumption Maximum 600 W

Dimensions 1041 (W) X 673 (D) X 800 (H) mm(When the door is open, the height is 1230 mm)

Weight 101.4 kg

Maximum Sample capacity 1-72 samples

TAT 3 hrs to process 72 samples(From NA extraction to PCR setup)

Deck capacity 5 x 12 (for 40 samples) , 5 x 18 (for 72 samples)

Pipetting channel 4 channels

Dispensing accuracy(when using 300㎕ Tip)

10㎕ : 3%, 50㎕ : 1.5%, 300㎕ : 1%

Dispensing precision (when using 300㎕ Tip) 10㎕ : 2%, 50㎕ : 1%, 300㎕ : 1%

• SPECIFICATION

www.seegene.comTaewon Bldg. 91 Ogeum-ro, Songpa-gu, Seoul 05548, Republic of Korea / Tel : +82-2-2240-4000 / Fax : +82-2-2240-4040 / E-mail : [email protected]

MIDDLE EASTDubai, UAETel : +971-4-558-7110 E-mail : [email protected]

USACalifornia, USATel : +1-925-448-8172E-mail : [email protected]

CANADAToronto, CanadaTel : +1-800-964-5680E-mail : [email protected]

BRAZILBelo Horizonte, BrazilTel : +55-31-25153003E-mail : [email protected]

MEXICOMéxico city, MéxicoTel : + 52 (55)-8848-9646E-mail : [email protected]

GERMANY Düsseldorf, GermanyvTel : +49-211-9943-4260E-mail : [email protected]