2
CM100 Receptor SC9000 Digital Receiver Alarm Control Panel Safecom SAFECOM Communication Paths SAFECOM RADIO PANEL Customer Site Back-up Communications Printer RF2000 Radio Modems 1 to 8 Automation Software Repeater Sites 1 to 8 SC9000 Receiver Digital Dialler T R FEATURES: 32 Programmable User Codes 2 Auxiliary Codes Entry Exit Warning 16 Programmable Burglary Zones Zone Lockout Swinger Shutdown Sensor Watch Day Alarm Remote Arming / Automatic Arming Answering Machine Bypass Safecom Telemetry System Built-in Dual Redundancy Transmission to Monitoring Centre is Instantaneous Supervises the System Constantly Partionable to Four Separate Areas Unique Fire Alarm Sound 6 Programmable Outputs - Expandable to 14 Outputs 4 Separate Entry Timers EDMSAT - Satellite Siren Compatible Walk Test Mode Dynamic Battery Testing Event Memory Recall Upload / Download Programmable SD-125 Radio is Warranted for 12 Months SPECIFICATIONS: Temp. Range: SC8016 -20° to +65°C (non-condensing) SD125 Radio -10° to +60°C (non condensing) Remote Outputs: 3 controllable from monitoring centre Power Supply: Determined by the amount of current required to drive any auxiliary devices Current Consumption: Panel + Interface 85mA (not in alarm) Codepads LCD=15mA, LED=55mA all LEDs on SD-125 55mA in Receive Mode 1.1A in Transmit Mode EDM Supplier #: N771 Detection Systems Australia Supplier #: N663 If an If an intruder intruder cuts your cuts your telephone telephone line... line... ...will your ...will your monitoring monitoring centre centre respond? respond? DS284TH Photoelectric Smoke Detector with Heat sensor DS840 TriTech Mirrored Optic PIR/Microwave Detector DS940 PIR Detector DS820i TriTech PIR/Microwave Detector DS303 PIR Detector Electronics Design & Manufacturing (A.C.N. 002 907 271) 5 Huntingwood Drive, Huntingwood NSW 2148, Australia Telephone: (61-2) 9672 1777 Facsimile: (61-2) 9672 1717 Available From: ACCESSORIES Security Solutions for the New Millennium

description

Security Solutionsfor the New Millennium

Transcript of Security Solutions for the New Millennium

Page 1: Security Solutions for the New Millennium

CM100

Receptor SC9000Digital Receiver

Alarm ControlPanel

Safecom

SAFECOM Communication Paths

SAFECOMRADIO PANEL

Customer Site

Back-upCommunications

Printer

RF2000Radio

Modems1 to 8

Automation Software

RepeaterSites1 to 8

SC9000 Receiver

Digital Dialler

T

R

FEATURES:� 32 Programmable User Codes

� 2 Auxiliary Codes

� Entry Exit Warning

� 16 Programmable Burglary Zones

� Zone Lockout

� Swinger Shutdown

� Sensor Watch

� Day Alarm

� Remote Arming / Automatic Arming

� Answering Machine Bypass

� Safecom® Telemetry System Built-in

� Dual Redundancy

� Transmission to Monitoring Centre isInstantaneous

� Supervises the System Constantly

� Partionable to Four Separate Areas

� Unique Fire Alarm Sound

� 6 Programmable Outputs - Expandable to 14 Outputs

� 4 Separate Entry Timers

� EDMSAT - Satellite Siren Compatible

� Walk Test Mode

� Dynamic Battery Testing

� Event Memory Recall

� Upload / Download Programmable

� SD-125 Radio is Warranted for 12 Months

SPECIFICATIONS:Temp. Range:SC8016 -20° to +65°C (non-condensing)SD125 Radio -10° to +60°C (non condensing)

Remote Outputs: 3 controllable from monitoring centre

Power Supply: Determined by the amount of current required to drive any auxiliary devices

Current Consumption:Panel + Interface 85mA (not in alarm)Codepads LCD=15mA, LED=55mA all

LEDs onSD-125 55mA in Receive Mode

1.1A in Transmit Mode

EDM Supplier #: N771

Detection Systems Australia Supplier #: N663

If anIf anintruderintrudercuts yourcuts yourtelephonetelephoneline...line...

...will your...will yourmonitoringmonitoringcentrecentrerespond?respond?

DS284TH PhotoelectricSmoke Detector with Heat sensor

DS840 TriTech®

Mirrored Optic

PIR/Microwave Detector

DS940 PIR

Detector

DS820i TriTech®

PIR/Microwave Detector

DS303

PIR Detector

Electronics Design & Manufacturing (A.C.N. 002 907 271)

5 Huntingwood Drive, Huntingwood NSW 2148, Australia

Telephone: (61-2) 9672 1777 � Facsimile: (61-2) 9672 1717

Available From:

ACCESSORIES

Security Solutions for the New Millennium

®

Page 2: Security Solutions for the New Millennium

If you are using a dialler based system, the monitoring centre has noway of telling whether your phone line (which your security system usesto transmit alarm messages) has been compromised.

EDM & Safecom® together...The EDM Solution SC8016 security system provides sophisticatedelectronic surveillance for your home or business. Incorporating the verylatest in wireless communications SAFECOM®, provides a high speed packet

telemetry signalling via a UHF data radio. Together, both systems providesuperior reliability and performance in alarm systems. Where othersystems rely solely on the telephone to transmit signals to the alarmcentre, SC8016 uses wireless telemetry signalling ensuring acontinuous monitoring of your system all the time.

How fast is Safecom® compared to adialer based system?All messages such as open and close reports,system status events and alarm messages aretransmitted from your site to the monitoringcentre in less than a quarter of a second. Likewe said, high speed signalling. Diallers maytake 30 seconds or more, depending on thesystem used. Safecom® is almostinstantaneous.

Double the supervisionSafecom® is so intelligent, your system listensinto communications with other Safecom®

systems in your area. If your system stopshearing Safecom® �air traffic� to other systems,it will use the phone line to warn the monitoringcentre that there is a problem. This effectivelygives you constant supervision, irrespective ofthe poll rate set for your system. Even if yoursystem was only polled once a day, your systemis constantly verifying its communication paths,both via the phone line and the wireless path.That�s real security!

What happens if my phone line getcut?The Safecom® system even supervises yourphone line and will alert the monitoring systemif your phone line is cut. If your wireless systemfails, we report wireless failure via the phoneline. In any case, as your system is supervised,your monitoring centre will know if either pathhas failed as your system is constantlysupervised.

How much does Safecom® costcompared to other supervisedsystems?Safecom® will cost a little more than aconventional dialler system and the monitoringfee will naturally be a little more than a diallersystem, however, when you factor in thereduction in call charges you will probably besaving money. At the same time, you will havea more secure system.

Do you know the real cost of your current monitoring system?If you have a commercial system with say four partitions, your dialler system may make more than40 calls per week to the monitoring centre at local call rates. If your system has multiple open andclose reports per day, the costs are even higher. With Safecom®, all call costs are eliminated as allreports are sent by wireless. No matter how many �calls� per day, there are no call charges.

What other benefits does Safecom® Provide?Safecom® provides a dual redundant path forcommunications. Not only does it prove a supervisedcommunications path, it can also provide a �dualredundant path� for emergencies. With Safecom®, yourprimary communications link to your monitoring centre iswireless, however, we can still connect your system to thephone lines as a back-up communications path. If onesystem is compromised, you have two communicationpaths to your monitoring centre. This is called dualredundancy�.

Sophisticated two-waycommunicationsThe Solution SC8016 provides sophisticated, two-way,dual path reporting and high supervision functions toyour security system. It helps to overcomeattempts by sophisticated criminals to compromiseyour system. Your authorized dealer will behappy to provide more information on theextraordinary features of Solution 16 system.

Technology is changing the way security systems are monitored and the Solution to line failure is SAFECOM®

TM

Security Solutions for the new millennium...visit our web site: www.edm.com.au � www.detectionsys.com

SC8016 Codepad

®