    Alternating Current

    24. Alternating Currents

    Content

    24.1 Characteristics of alternating currents

    24.2 The transformer

    24.3 Transmission of electrical energy

    24.4 Rectification

    Learning Outcomes

    Candidates should be able to:

    (a) show an understanding of and use the terms period, frequency, peak valueand root-mean-square value as applied to an alternating current or voltage.

    * (b) deduce that the mean power in a resistive load is half the maximum power

    for a sinusoidal alternating current.* (c) represent a sinusoidally alternating current or voltage by an equation of the

    form x = xosint.

  • 7/28/2019 Section v 24 Alternating Currents

    2/25

    (d) distinguish between r.m.s. and peak values and recall and solve problems using the

    relationship Irms = Io/2 for the sinusoidal case.

    (e) show an understanding of the principle of operation of a simple iron-cored

    transformer and recall and solve problems using Ns/Np = Vs/Vp = Ip /Is for an ideal

    transformer.

    (f) show an appreciation of the scientific and economic advantages of alternating

    current and of high voltages for the transmission of electrical energy.

    * (g) distinguish graphically between half-wave and full-wave rectification.

    (h) explain the use of a single diode for the half-wave rectification of an alternating

    current.

    (i) explain the use of four diodes (bridge rectifier) for the full-wave rectification of analternating current.

    * (j) analyse the effect of a single capacitor in smoothing, including the effect of the

    value of capacitance in relation to the load resistance.

  • 7/28/2019 Section v 24 Alternating Currents

    3/25

    Direct current

    When a battery is connected to a circuit, the current flows steadilyin one direction

    This sort of current is known as direct currentor in short d.c.

    However the domestic and industrial electricity supply producedby generators at a power station is one which does not use directcurrent but alternating current

    Direct current Alternating current

    0 Time

  • 7/28/2019 Section v 24 Alternating Currents

    4/25

    Alternating currents

    An alternating current (a.c.) or voltage is one which continuouslyreverses its direction of flow after a certain interval of time, that is, it

    varies in magnitude and direction with time. The amplitude or magnitude of such a current (for a a.c of sinusoidal wave

    form) at any time frame is as follows:

    I = I0sin t I = I0sin 2ft I = I0sin 2(t/T)where, I = current at any time t in amperes A

    I0 = peak current= 2f, angular frequency, rad s-1f= /2, frequency in Hz or no. of cycles per second

    T = 1/f= period in seconds

    The time for one complete alternation, a cycle, is the period T. The number

    of cycles in one second is the frequency f. The frequency of an alternatingcurrent may range from 50 Hz to 100 Hz. Fore.m.f., the same formulaeapply

    Sometimes the term peak-to-peak is used which means 2Io or 2Vo i.e. twicethe amplitude value

  • 7/28/2019 Section v 24 Alternating Currents

    5/25

    Other forms of alternating currents

    The following are some other wave forms of alternating currents produced by specially-

    designed electronic circuits:

    I orV 1 cycle I orV 1 cycle

    I0

    t t

    T/2 T

    Saw-toothed wave Square wave

  • 7/28/2019 Section v 24 Alternating Currents

    6/25

    Power in a resistor From the picture of a sinosoidal wave although it is clear that the average

    value of an alternating current is zero, it does not mean that when an a.c

    source is connected to a resistor, no power is generated in the resistor

    Using I = I0sin t and the powerP = I2R generated in a resistance RP = Io

    2R sin2t Because Io

    2 and sin2t are always positive, the powerP is alwayspositive

    The above expression gives the power at any instant of time, but what ismuch more useful is the average or mean power which is the powergenerated in the resistor

  • 7/28/2019 Section v 24 Alternating Currents

    7/25

    Root-Mean-Square (r.m.s.) value of an A.C. The root-mean-square value of an alternating current is defined as the equivalent

    value of the steady d.c. which would dissipate energy at the same average rate in a

    given resistance. It is also called the effective value of an a.c. A direct current with a value ofI equal to the r.m.s current Irms of an a.c. circuit

    will produce exactly the same heating effect in a resistor

    Because the current in an a.c. changes direction many times in a second, theeffective value of the current (Irms or Ir) is thus an average value of currents Ithroughout one whole cycle of the currents sinusoidal wave.

    Pac = Idc2R = Ir2R

    Ir2 = average value of I2= I0

    2/2

    Ir = I0/2 = I0/1.414 = 0.707 I0 Similarly,Vr = V0/2 V0 =2 Vr In specifying a domestic supply voltage, it is the r.m.s. value that is quoted

    If the voltage of an a.c. mains supply is 240 V (r.m.s.), an electrical appliance mustbe able to stand up to a peak value of2 x 240 V (= 339.4 V) in order for it to beable to be used on the mains.

    The r.m.s value of the current or voltage is that value of the direct current or

    voltage that would produce heat at the same rate in a resistor

  • 7/28/2019 Section v 24 Alternating Currents

    8/25

    R.m.s. the mathematics

    The r.m.s value of a function f(x) within the range ax b isgiven by:

    2

    1

    2

    )(1

    dxxfabb

    a

    If f(x) = sin x and integrating for x between x = 0 and x = 2

    gives

    2

    12

    2

    0sin

    02/

    1

    dxx

    = 2

    1

    2

    0)2cos1(

    2

    dxx

    =

    21

    2

    1

    =2

    1

  • 7/28/2019 Section v 24 Alternating Currents

    9/25

    Mean power of a.c.

    Mean power Pac = Ir2R= (I0/2)2.R= 1/2 ( I0

    2R) = 1/2 P0 That is, mean power is half the maximum power or peak power for an a.c. passing

    through a resistive load.

    V = V0.sint I = I0.sint

    0 t

    P

    I02R P =( I0

    2.sin2t).R

    1/2 I02R

    0 t

  • 7/28/2019 Section v 24 Alternating Currents

    10/25

    Example

    A 1.5 kW heater is connected to the domestic supply which is quoted as 240V. Calculate the peak current in the heater, and its resistance.

    Solution

    From P = Vrms x Irms , Irms = 1500/240 = 6.3 A

    Hence peak current I0 is 6.3 x 1.414 = 8.8 Aand the resistance R = Vrms/Irms = 240/6.3 = 38 ohms

  • 7/28/2019 Section v 24 Alternating Currents

    11/25

    Transformer principles

    A transformer is a device used for stepping-up (or down) an a.c. supplyvoltage using the Mutual Induction Principle. Basically it consists of two coilsof wires, one called the primary and the other the secondary, of anappropriate number of turns. These coils normally wind round a laminatedsoft-iron core for better permeability of the magnetic field or flux linkage ofthe two coils giving a higher flux.

    When an alternating voltage Vp is applied to the primary coil, it sets up afluctuating magnetic field which in turn induces a back e.m.f. Ep. The currentIp in the primary coil is given by:

    Vp -Ep= Ip.Rp( Rp=primary coil resistance )As p = Np

    Ep = dp/dt = Npd/dt For an ideal transformer, Rp 0 giving VpEp.

    i.e. Vp = Npd/dtwhere Np is the number of turns in the primary coil and the flux in the ironcore linking the coils.

  • 7/28/2019 Section v 24 Alternating Currents

    12/25

    cont..

    At the secondary coil where it is connected to a load, the output voltage Vs isgiven by:

    Vs = Es -IsRs ( Rs= secondary coil resistance )

    and Es is the mutually induced e.m.f. in the secondary coil.

    Es = ds/dt = Nsd/dt Again, for an ideal transformer, Rs 0 giving VsEs.

    i.e. Vs = Nsd/dt Vs/Vp = Ns/Np

  • 7/28/2019 Section v 24 Alternating Currents

    13/25

    cont..

    The voltage Vp applied to the primary, from the source current, is usedsimply in overcoming the back-e.m.f. Ep., if we neglect the resistance of thewire. Therefore, it is equal in magnitude to E

    p. (This is analogous to saying,

    in mechanics, that action and reaction are equal and opposite.)

    For an ideal transformer (i.e. 100% efficient), the power supply in the primarycoil will be fully transferred to the secondary output.

    Hence: VpIp= VsIs or Vs/Vp= Ip/Is

    Thus for an ideal transformer,

    So the transformer steps voltage up or down according to its 'turns-ratio'.The voltage may be stepped up from 25,000 to 400,000 volts for high-

    tension transmission and stepped down from 240 V to 6 V for ringing bells.

    s

    p

    p

    s

    p

    s

    I

    I

    N

    N

    V

    V

    primaryinvoltageApplied

    secondaryine.m.f.Induced

  • 7/28/2019 Section v 24 Alternating Currents

    14/25

    Energy Losses and Efficiency in Transformer There are 4 main losses:

    (a)Heat is lost in coils (primary and secondary) due to resistance of the

    windings. For transformers handling very high electrical power, the windingsare made of very thick wires to reduce power lost as heat. The windings areinsulated and immersed in oil for cooling purpose.

    (b)The alternating flux in the primary induces eddy current in the iron core thatcauses heat loss.

    (c)The magnetisation and demagnetisation of the iron core give rise to the

    hysteresis loss and hence power loss.(d)When the flux produced by the primary is not 100% linked to the secondary,

    then the input electrical power will not be fully transferred to the secondaryoutput as flux leakage occurs. (does not pass through iron core).

    Efficiency = (power in secondary/power in primary) x 100%

  • 7/28/2019 Section v 24 Alternating Currents

    15/25

    Electrical power transmission

    When electricity is transmitted from a source, such as a power station to adistant load, such as a factory or household, power is lost as Joule heatingI2R through the transmission cables where R is the total resistance of thecables.

    Suppose the electrical power generated Pgenis to be delivered at a p.d. ofVby the supply lines of total resistance R.The current in thesupply line willbe:

    I = Pgen/V

    Hence, the power loss as heat will be given by:Ploss= I

    2R = (Pgen/V)2R

    The equation indicates that for lower power loss, V has to be high in value.Hence for economic reasons, transmission must be at high V and low I state.But a low I means a thicker and costlier cable while higher voltage will resultin higher insulation cost. The result is a solution taking cable resistance, thevoltage of transfer and insulation cost into consideration.

    Example

  • 7/28/2019 Section v 24 Alternating Currents

    16/25

    Example(1) A power station generates a power of 200 MW at a potential difference of

    400 kV. This input power is transmitted to a distant town through a pair ofoverhead lines whose total resistance is 5.0 .

    (a) Calculate (i) the current in the wires (ii) the voltage between the terminalsat the far end of the lines.

    (b) State, in each case, a reason why the designers of the transmissionsystem did not choose an input voltage of: (i) 240 V (ii) 2.0 MV.

    (c) (i) Give one example of a situation where it is essential to route powercables underground. (ii) State one disadvantage, other than high cost, oflaying power cables underground.

    Solution

    (a) (i) I = P/V = 200 x 106/(400 X 103) = 500 A

    (ii) Voltage drop = IR = 500 x 5.0 = 2500 = 2.5 kV

    Voltage between terminals at far end of lines = 400 2.5 = 397.5 kV

    (b) (i) Current high, hence requires thick expensive cables.(ii) Need tall pylons, wide cables spacing, costly insulation, possible

    discharge in air.

    (c) (i) Airfields; wide stretches of water.

    (ii) Difficult to dissipate heat; insulation problems; risk of damage bydigger; difficulty of access if faults arise; biological effects ofelectric/magnetic fields/radiation from currents near ground level.

  • 7/28/2019 Section v 24 Alternating Currents

    17/25

    Electrocution

    Electrocution is actually due to the amount of current that flows through thebody.

    The amount of current depends on the resistance offered by the personbetween the wire and the earth.

    A current of 0.1 A is able to cause death due to fibrillation (uncontrolledcontractions of the heart).

    People touching live wires may get their hand stuck to the wire due tocontraction of the muscles. It is therefore current, not voltage, which is

    dangerous.

  • 7/28/2019 Section v 24 Alternating Currents

    18/25

    Rectification

    A.C. is important and useful in power generation and distribution since a.c.can be stepped up for minimum power-loss transmission.

    For electrical and electronic devices operating on d.c. sources only (e.g.radio, television, computers etc.), rectification of the a.c. (i.e. to change it tod.c.) is necessary through use of appropriate rectifiers (diodes)

    Alternating current can be converted to direct current (i.e. rectified) bymaking use of devices which conduct appreciable amounts of current in onedirection only. Such devices are called rectifiers and include thermionicdiodes, metal rectifiers and semiconductor diodes.

    A rectifier is an electrical device which converts alternating current todirect current, a process known as rectification. Rectifiers are used ascomponents of power supplies and as detectors of radio signals.

    Rectifiers may be made of solid state diodes, vacuum tube diodes, mercuryarc valves, and other technologies.

  • 7/28/2019 Section v 24 Alternating Currents

    19/25

    cont..

    A rectifier is said to be forward-biased when it isconnected to a power supply in such a way that itconducts. If connected the other way, the rectifier isreverse-biased. The current-voltage curve of atypical rectifier is shown below:

    Current through rectifier

    Low-resista nce when

    Forward-biased

    O PD across rectifier

    High-resistance when reverse-biased

  • 7/28/2019 Section v 24 Alternating Currents

    20/25

    Half-wave rectification by a single diode

    The rectifier conducts only during thehalf cycle which means that the outputacross the load will consist of only the

    positive half-cycles. Although theoutput is pulsating, it is unidirectional,i.e. direct current.

    X

    Alternating supply Load

    Y

    Supply PD

    O t

    PD acrossload

    O t

  • 7/28/2019 Section v 24 Alternating Currents

    21/25

    Full-wave rectification It is more satisfactory also to make use of

    the negative hal-cycles as well and this canbe achieved by using an arrangement of 4rectifiers (diodes) known as a bridge

    rectifier. When P is positive, diodes across PQ and

    SR conduct; when R is positive, diodesacross RQ and SP conduct. In each case thecurrent through the load is in the samedirection from Q to S. The p.d. across theload has the form shown below.

    Thus, full-wave rectification allows the

    load to draw current from the supply oneach half of each cycle and therefore thepower that can be utilized is double thatachieved with half-wave rectification.

    P.D. across

    load

    O t

  • 7/28/2019 Section v 24 Alternating Currents

    22/25

    Smoothing by a single capacitor

    The pulsating unidirectional rectified current output produced by both half-wave and full-wave rectifiers is still not a good approximation to the steady

    direct current required for most electronic equipment It can be made more steady (smoothed) by inserting a suitable capacitor in

    parallel with the load or across the output terminals of the bridge circuit The effect is to reduce the fluctuations in the unidirectional output Generally a larger value of the capacitor will give better smoothing although the

    more important factor is the resistor-capacitortime-constant

    X

    Pulsating Smoothing Load CurrentRectified p.d. capacitor

  • 7/28/2019 Section v 24 Alternating Currents

    23/25

    cont..

  • 7/28/2019 Section v 24 Alternating Currents

    24/25

    cont.. As the rectifier voltage increases, it charges the capacitor and also supplies current to

    the load. At the end of the quarter cycle the capacitor is charged to its peak value Vm ofthe rectifier voltage. Following this the rectifier voltage starts to decrease as it enters

    the next quarter cycle. This initiates the discharge of the capacitor through the load. At points such as A the p.d. across the load has just reached its maximum value. If the

    capacitor were not present, the p.d. would start to fall to zero along the broken curve.However, as soon as the p.d. across the load starts to fall, it becomes less than thatacross the capacitor and the capacitor starts to discharge through the load. Since thecharging process causes plate X to be positive, the discharge drives current through theload in the same direction as it flowed during charging.

    P.D. across Smoothed p.d.

    load A Ripplevoltage

    O time

    Unsmoothed half-wave rectified p.d.

    P.D. across

    Load A Smoothed p.d.

    O time

    Unsmoothed half-wave rectified p.d.