SEALED BURNER RANGETOPS - Winning Appliances · sealed burner rangetops installation instructions...

20
SEALED BURNER RANGETOPS INSTALLATION INSTRUCTIONS Rangetop series ICBSRT ICBSRT364C ICBSRT364G ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F Models ICBSRT304

Transcript of SEALED BURNER RANGETOPS - Winning Appliances · sealed burner rangetops installation instructions...

SEALED BURNER RANGETOPSINSTALLATION INSTRUCTIONS Rangetop series ICBSRT

ICBSRT364CICBSRT364GICBSRT486CICBSRT486GICBSRT484CGICBSRT484F

Models ICBSRT304

33

As you follow these instruc tions, you willnoticeWARNING and CAUTION symbols. Thisblocked information is impor tant for the safeand efficient installation of Wolf equipment.There are two types of potential hazards thatmay occur during installation.

Another footnote we would like to identify isIMPORTANT NOTE: This highlights informa-tion that is especially relevant to a problem-free installation.

signals a situation where minor injury orproduct damage may occur if you do notfollow instructions.

states a hazard that may cause seriousinjury or death if precautions are notfollowed.

WOLF® is a registered trademark of Wolf Appliance, Inc.

CONTACTINFORMATION

Sub-Zero Group Australia Pty Ltd

Level 10, 469 La Trobe Street

Melbourne Victoria 3000

Phone 03 9600 2218

subzero-wolf.com.au

4

W O L F S E A L E D BUR N E R R A N G E TO P

I N S TA L LAT I ON R E Q U I R E M E N T S

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in yourbuilding.

Immediately call your gas supplierfrom a neighbor’s phone. Followthe gas supplier’s instructions.

If you cannot reach your gasIMPORTANT NOTE:

Installation and service must be

Do not store or use gasoline orother flammable vapors and liquidsin the vicinity of this or any otherappliance.

The use of a gas cooking applianceresults in the production of heat andmoisture in the room in which it isinstalled. Ensure that the kitchen iswell ventilated; keep natural ventila-tion holes open or install a mechani-cal ventilation device (mechanicalextractor hood)

Prolonged intensive use of the appli-ance may for additional ventilation,for example opening of a window, or more effective ventilation, forexample increasing the level ofmechanical ventilation where

This appliance shall be installed

in accordance with the regula-

tions in force and only used in a

well ventilated space. Read the

instructions before installing or

using this appliance.

WHAT TO DO IF YOU SMELL GAS:

STATUTORY REQUIREMENTS

supplier, call the fire department.

This appliance shall be installedin accordance with the manufacturer’sinstallation instructions, local gasfitting regulations, municipal buildingcodes, electrical wiring regulations,and AS/NZS 5601 the AustralianStandard for gas installations. Referalso to AS/NZS 5601 for gas pipesizing tables.

Not suitable for use in marine craft,caravan or mobile home. Unless eachburner is fitted with a flame safeguard.

The appliance must not be modified. performed by an authorized person.

present.

A ventilation range hood must be installed for use with the Wolf sealed burner rangetops.

5

W O L F S E A L E D BUR N E R R A N G E TO P

R AT I N G P L AT EI N F O R M AT I O N

Model Number

Serial Number

I N S TA L LAT I ON R E Q U I R E M E N T S

IMPORTANT NOTE: This installation must

be completed by a qualified installer,

service agency or gas supplier.

IMPORTANT NOTE: Save these InstallationInstructions for the local inspector’s use.

Please read the entire Installation Instruc-tions prior to installation.

Installer: please retain these instructionsfor local inspector’s reference, then leavethem with the homeowner.

Homeowner: please read and keep theseinstructions for future reference and be sureto read the entire Use & Care Informationprior to use.

IMPORTANT NOTE: This appliance must beinstalled in accordance with local codes. Thecorrect voltage, frequency and amperage mustbe supplied to the appliance from a dedicated,grounded circuit which is protected by aproperly sized circuit breaker or time delayfuse. The proper voltage, frequency, andamperage ratings are listed on the productrating plate.

Record the model and serial numbers beforeinstalling the sealed rangetop. Both numbersare listed on the rating plate, located on theunderside of the sealed rangetop. Refer to theillustration below.

BEFORE YO U S TA RT

Proper installation is your responsibility.Have a qualified technician install thissealed rangetop. You must also assure thatelectrical installation is adequate and incompliance with all local codes and ordi-nances.

Prior to installation, ensure that the localdistribution conditions (nature of the gasand gas pressure) and the adjustment ofthe appliance are compatible.

Proper gas supply connection must beavailable; refer to Gas Supply Requirementson page 12. Electrical ground is required;see Electrical Requirements on page 15.

The adjustment conditions for this appli-ance are stated on the label (or ratingplate). The data plate can be found on theunderside of the sealed rangetop.

Rating plate location

Location of rating plateunder control panel

6

I N S TA L LAT I ON I N S T R U C T I O N S

BEFORE YO U S TA RT

Check the location where the rangetop willbe installed. The location should be awayfrom strong draft areas, such as windows,doors and strong heating vents or fans. Donot obstruct the flow of air. The area inwhich you are installing this appliance musthave an adequate supply of fresh air toensure proper combustion and ventilation.

This appliance is not connected to acombustion products evacuation device. It shall be installed and connected in accor-dance with current installation regulations.Particular attention shall be given to therelevant requirements regarding ventilation.

All openings in the wall where the rangetopis to be installed must be sealed.

I N S TA L LAT I ON S P E C I F I C AT I O N S

Wolf sealed burner rangetops come in 762 mm, 914 mm and 1219 mm widths. Illus-trations on pages 9–11 provide the overalldimensions and installation specifications foreach width of sealed burner rangetop.

Each rangetop is designed to fit betweencabinets set at the distance specified by theunit. For example, a 914 mm rangetop will fit a914 mm opening.

IMPORTANT NOTE: Cabinet opening dimen-sions shown in the Installation Specificationsillustrations must be used. These dimensionsprovide for required clearances.

IMPORTANT NOTE: Locate the electricalsupply within dimensions shown in theInstallation Specifications illustrations.

Refer to the Installation Specifications illustra-tion for your model on pages 9–11 for theexact rough opening dimensions and locationof the gas and electrical supply.

I S L A N D | P E N I N S U L A I N S TA L L AT I O N S

Minimum clearances to combustiblesurfaces:

Island Installations: Minimum 305 mmclearance to rear wall that rises above thecountertop.

Peninsula Installations: Minimum 152 mmclearance to side walls and minimum 305 mm clearance to rear wall that risesabove the countertop.

Refer to the Installation Specificationsillustration for your model on pages 9–11 for the exact rough opening dimensions.

7

W O L F SEALED BURNER RANGETOP

MINIMUM C L E A R A N C E S

IMPORTANT NOTE: Caution must be usedin planning the proper installation of the Wolfsealed burner rangetop to avoid fire ordamage to adjacent cabinetry or kitchenequipment. Be sure to follow the minimumclearances established in the finished roughopening dimensions.

Refer to the Installation Specificationsillustration for your model on pages 9–11 for the exact rough opening dimensions.

WA L L I N S TA L L AT I O N S

Minimum clearances to combustiblesurfaces:

Minimum 457 mm clearance from bottomof upper cabinet to countertop, within 152 mm minimum side clearance.

Minimum spacing between overhead sidecabinets must be greater than or equal tothe nominal width of the rangetop. Themaximum depth of overhead and sidecabinets is 330 mm, within 152 mm sideclearance.

0 mm clearance for adjacent combustiblematerials below the countertop, both sidesand rear.

Bottom of ventilation hood must be 762 mm minimum to 914 mm maximumfrom countertop.

Minimum clearances for sealed burnerrangetops without a ventilation hood:

Model ICBSRT304: 762 mm minimumvertical distance from countertop tocombustible materials above the rangetop.

All Other Sealed Burner Rangetops:

Surface Burners or Griddle (G) Models:914 mm minimum vertical distance fromcountertop to combustible materials abovethe rangetop.

Charbroiler (C) Models: 1118 mm minimumvertical distance from countertop tocombustible materials above the rangetop.

Failure to locate the rangetop withoutthe proper clearances will result in a firehazard.

R I S E R R E Q U I R E M E N T S

Installations against a combustible surface:

Model ICBSRT304: No riser requirements.

914 mm Sealed Burner Rangetops: Aminimum 254 mm riser is required for allcharbroiler (C) or griddle (G) modelsinstalled against a combustible surface.

1219 mm Sealed Burner Rangetops: Aminimum 254 mm riser is required for allcharbroiler (C) or griddle (G) modelsinstalled against a combustible surface.

V E N T I L A T I O N

A suuitable ventilation range hood must be installed.

Important Note: It is recommended thatyou operate the Wolf Sealed Burner Rangetopwith a Wolf Pro ventilation hood. Contact your Wolf dealer for details.

Important Note: When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop.

8

I N S TA L LAT I ON I N S T R U C T I O N S

VENTILATIONHOOD

762 mmOPENING WIDTH

762 mm minTO 914 mm maxTO BOTTOM OF

VENTILATION HOOD

762 mm minCOUNTERTOP

TO COMBUSTIBLEMATERIALS

19 mmPLATFORM

TOP VIEWOF PLATFORM

E G

406 mm

406 mm

102 mm BACKWALL

ISLAND INSTALLATIONS: 305 mm MINIMUMCLEARANCE FROM BACK OF RANGETOP TO

COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–0 mm TO NON-COMBUSTIBLE MATERIALS

LOCATION OF GAS ANDELECTRICAL SUPPLY CUT-OUT

WITHIN SHADED AREATHROUGH BOTTOM OF

PLATFORM

914 mm

457 mm minTO COUNTERTOP

19 mmPLATFORM

216mm

COOKINGSURFACE

191 mm

610 mm

330 mmmax

152 mm minTO

COMBUSTIBLEMATERIALS

(BOTH SIDES)

759 mmOVERALL WIDTH

616 mm

318mmWITH

127 mmRISER

445mmWITH

254 mmRISER

699mmWITH

508 mmRISER

724 mmOVERALL DEPTH

216 mmOVERALLHEIGHT

COOKINGSURFACE

191mm

235mm

I N S TA L L AT I O N S P E C I F I C AT I O N S

O V E R A L L D I M E N S I O N S

Overall Width 759 mm

Overall Height(to cooking surface) 216 mm

Overall Depth 724 mm

Dimensions may vary to ±3 mm.

762 mm S E A L E D B U R N E R R A N G E TO P

Opening Width 762 mm

Note A:Side clearances. If the distancemeasured from the periphery of thenearest burner to any vertical surfaceis less than 200 mm, the surface shallbe protected in accordance with AS/NZS 5601

Note B:The rangehood fitted above thecooktop must be installed accordingto the installation instructions forthe rangehood. A minimumdistance of 750 mm is required for arange hood and 750 mm for anexhaust fan.

9

W O L F S E A L E D BUR N E R R A N G E TO P

VENTILATION HOOD

914 mmFINISHED ROUGH OPENING WIDTH

762 mm min TO914 mm max

TO BOTTOM OFVENTILATION HOOD

914 mm minCOUNTERTOP

TO COMBUSTIBLEMATERIALS

1118 mm minFOR CHARBROILER

19 mmPLATFORM

TOP VIEWOF PLATFORM

E G

406 mm

406 mm

102 mm BACKWALL

ISLAND INSTALLATIONS: 305 mm MINIMUMCLEARANCE FROM BACK OF RANGETOP TO

COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–0 mm TO NON-COMBUSTIBLE MATERIALS

LOCATION OF GAS ANDELECTRICAL SUPPLY CUT-OUT

WITHIN SHADED AREATHROUGH BOTTOM OF

PLATFORM

914 mm

457 mm minTO COUNTERTOP

19 mmPLATFORM

216mm

COOKINGSURFACE

191 mm

610 mm

330 mmmax

152 mm minTO

COMBUSTIBLEMATERIALS

(BOTH SIDES)

911 mmOVERALL WIDTH

616 mm

724 mmOVERALL DEPTH

216 mmOVERALLHEIGHT

COOKINGSURFACE

191mm

235mm

445mmWITH

254 mmRISER

699mmWITH

508 mmRISER

I N S TA L L AT I O N S P E C I F I C AT I O N S

O V E R A L L D I M E N S I O N S

Overall Width 911 mm

Overall Height(to cooking surface) 216 mm

Overall Depth 724 mm

Dimensions may vary to ±3 mm.

914 mm S E A L E D B U R N E R R A N G E TO P

IMPORTANT NOTE:A minimum 254 mmriser is required forall charbroiler (C) orgriddle (G) modelsinstalled against acombustible surface.

Opening Width 914 mm

instructions for future reference and be sureHomeowner: please read and keep these

Note A:Side clearances. If the distancemeasured from the periphery of thenearest burner to any vertical surfaceis less than 200 mm, the surface shallbe protected in accordance withAS/NZS 5601

Note: BThe rangehood fitted above thecooktop must be installed accordingto the installation instructions forthe rangehood. A minimumdistance of 750 mm is required for arange hood and 750 mm for an exhaust fan.

10

I N S TA L LAT I ON I N S T R U C T I O N S

VENTILATION HOOD

1219 mmFINISHED ROUGH OPENING WIDTH

762 mm min TO914 mm max

TO BOTTOM OFVENTILATION HOOD

914 mm minCOUNTERTOP

TO COMBUSTIBLEMATERIALS

1118 mm minFOR CHARBROILER

LOCATION OF GAS ANDELECTRICAL SUPPLY CUT-OUT

WITHIN SHADED AREATHROUGH BOTTOM OF

PLATFORM

19 mm PLATFORM

TOP VIEWOF PLATFORM

E G

406 mm

406 mm

102 mm BACKWALL

ISLAND INSTALLATIONS: 305 mm MINIMUMCLEARANCE FROM BACK OF RANGETOP TO

COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–0 mm TO NON-COMBUSTIBLE MATERIALS

914 mm

457 mm minTO COUNTERTOP

19 mmPLATFORM

216mm

COOKINGSURFACE

191 mm

610 mm

330 mmmax

152 mm minTO

COMBUSTIBLEMATERIALS

(BOTH SIDES)

1216 mmOVERALL WIDTH

616 mm

724 mmOVERALL DEPTH

216 mmOVERALLHEIGHT

COOKINGSURFACE

191mm

235mm

318mmWITH

127 mmRISER

445mmWITH

254 mmRISER

699mmWITH

508 mmRISER

I N S TA L L AT I O N S P E C I F I C AT I O N S

O V E R A L L D I M E N S I O N S

Overall Width 1216 mm

Overall Height(to cooking surface) 216 mm

Overall Depth 724 mm

Dimensions may vary to ±3 mm.

1219 mm S E A L E D B U R N E R R A N G E TO P

IMPORTANT NOTE:For 1219 mm sealedburner rangetops,a minimum 254 mmriser is required forall charbroiler (C) orgriddle (G) modelsinstalled against acombustible surface.

Opening Width 1219 mm

Note A:Side clearances. If the distancemeasured from the periphery of thenearest burner to any vertical surfaceis less than 200 mm, the surface shallbe protected in accordance withAS/NZS 5601

Note B:The rangehood fitted above thecooktop must be installed accordingto the installation instructions forthe rangehood. A minimumdistance of 750 mm is required for arange hood and 750 mm for anexhaust fan.

11

W O L F S E A L E D BUR N E R R A N G E TO P

I M P O RTA N TN OT E

This installation

must conform with

local codes and

ordinances.

I N S TA L L T H E R A N G E TO P

Prepare the finished rough opening for therangetop according to the Installation Specifi-cations illustration for your model on pages9–11. The platform must be 19 mm thick andinclude a cut-out at the right rear for gassupply and electrical connections.

IMPORTANT NOTE: The platform must belevel to ensure that the cooking surface islevel.

Remove and discard all packing materials,including cardboard and tape on the outside ofthe rangetop. Remove the burner grates andstyrofoam off the top cooking surface. Besure to remove the burner caps packaged instyrofoam below the burner grates.

If your installation requires a riser, it must beattached to the rangetop before installation.Refer to the installation instructions packagedwith the riser.

Position the rangetop on the platform. Gassupply and electrical connections should bemade before the rangetop is placed in its final

IMPORTANT NOTE: The sealed rangetop mustbe connected to a regulated gas supply.

IMPORTANT NOTE: This installation mustconform with local codes and ordinances.

The rating plate, located on the underside ofthe burner box, has information on the type ofgas that should be used. If this informationdoes not agree with the type of gas available,check with the local gas supplier.

An ISO 7-1 gas inlet thread is provided on allunits. Please contact your local Wolf dealer ifan ISO 228-1 or other gas inlet thread isrequired. Pipe joint compounds, suitable foruse with LP gas should be used. LP gas suppli-ers usually determine the size and materials

If rigid pipe is used as a gas supply line, acombination of pipe fittings must be used toobtain an in-line connection to the sealedrangetop. All strains must be removed fromthe supply and gas lines so the sealed

EXPLOSION HAZARD—

Securely tighten all external gas

connections.

Failure to do so can result in explosion,

fire or death.

GAS SUPPLY R E Q U I R E M E N T S

used on the system.

Flexible hose must be certified to AS1869 class B or D10mm in diameter and no longer than 1200mm long.The hose must not be kinked or be able to touch anyhot surface. The supply connection point must beaccessible when installed.

rangetop will be level and in line.

position.

GAS CONNECTION:Fit regulator (N.G.) or Propane fitting (LPG), the direction for gas flow is indicated on the regulator.Check correct operation of each burner individuallyand in combination. Burner flames should be clear

abnormality, check that the burner heads are blue, with no yellow tipping. If the burners show any

correctly located and refer to trouble shooting page 16. If satisfactory performance can not be obtainedcontact Multyflex or the local gas utility.Note: These burner have no aeration adjustment.

Instruct the user in the operation of the appliancebefore leaving. A duplicate plate can be attached tothe inside top of an adjacent cupboard.

12

INSTAL LATI ON I N S T R U C T I O N S

GAS R AT I N G

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Model No: ICBSRT486GSerial No:Gas type NG LPGTest point press. (kPa) 1.0 2.75Injector sizes (mm)

RHF/CF 1.80 1.09RHR/CR 1.80 1.09Griddle 1.70 1.09LHF 1.80 1.09LHR 1.35 0.89

Total Consumption (MJ/h) 94.0 94.1Electrical compliance: in accordance withAS/NZS3100 240 V AC, 10 amps, 50 Hz

Made in USA

MF0

49

GSCS20230SAI GLOBAL

AS4551

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218

GAS SUPPLY R E Q U I R E M E N T S

G A S L E A K T E S T I N G

Use a brush and liquid detergent to test all gasconnections for leaks. Bubbles around connec-tions will indicate a leak. If a leak appears, shutoff the gas valve and adjust connections. Thencheck connections again. Clean all the deter-gent solution from the rangetop.

13

W O L F S E A L E D BUR N E R R A N G E TO P

Never test for a gas leak with a match or

other flame.

14

I N S TA L LAT I ON I N S T R U C T I O N S

E LECTRICAL R E Q U I R E M E N T S

ELECTRICAL SHOCK HAZARD—

Plug into a grounded 3-prong adapter.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these instructions can

result in electric shock, fire or death.

R E C O M M E N D E D G R O U N D M E T H O D

IMPORTANT NOTE: For your personal safety,this sealed rangetop must be grounded. Thissealed rangetop is equipped with a 3-prongground plug. To minimize possible shockhazard, the cord must be plugged into amating 3-prong ground-type outlet, groundedin conformance with all local codes and ordi-nances. If a mating outlet is not available, it isthe obligation of the customer to have aproperly grounded, 3-prong outlet installed bya qualified electrician.

IMPORTANT NOTE: If product is connected toa GFCI protected outlet, nuisance tripping ofpower supply may occur, resulting in loss ofproduct operation.

W I R I N G D I A G R A M

The wiring diagram covering the electricalcircuit is located on the inside left wall of therangetop.

IMPORTANT NOTE: If codes permit and aseparate ground wire is used, it is recom-mended that a qualified electrician determinethat the ground path is adequate.

IMPORTANT NOTE: Check with a qualifiedelectrician if you are not sure whether thesealed rangetop is properly grounded.

IMPORTANT NOTE: Do not ground to a gaspipe.

A 220-240 V AC, 50/60 Hz, fused electricalsupply is required. A time-delay fuse or circuitbreaker is recommended. It is recommendedthat a separate circuit serving only this appli-ance be provided.

Electronic ignition systems operate withinwide voltage limits, but proper ground andpolarity are necessary. In addition to checkingthat the outlet provides 220-240 V AC powerand is correctly grounded, the outlet must bechecked by a qualified electrician to see if it iswired with correct polarity.

This appliance, when installed, must be electri-cally grounded in accordance with local codes.

15

W O L F S E A L E D BUR N E R R A N G E TO P

SURFACE B U R N E R S

I N I T I A L L I G H T I N G

The surface burners use electronic igniters inplace of standing pilots. When the sealedrangetop control knob is pushed in and turnedto the position, the system creates a sparkto light the burner. This sparking continuesuntil the electronic ignition senses a flame. Ifthe burner fails to ignite after 10 seconds,return the knob to the position and attemptto ignite by turning the knob back to the position.

Be sure to place the burner heads and caps oneach burner base and position the burnergrates over the burner bases and heads beforelighting.

To check operation of the surface burners,push in and turn each control knob to the position. The flame should light within fourseconds.

If the burners do not light properly, turncontrol knob to the position. Check that theburner heads and caps are in the properposition. Check that the power supply cord isplugged in and that the circuit breaker orhouse fuse has not blown. Check operationagain, if the burners do not light properly atthis point, contact a Wolf authorized servicecenter.

IMPORTANT NOTE: Initial lighting of thesurface burners may take slightly longer, as airin the system must be purged before gas canbe supplied to the burner.

S E A L E D R A N G E TO P R E M O VA L

If it is necessary to remove the sealedrangetop for cleaning or service, shut off thegas supply. Disconnect the gas and electricsupply. Remove the mounting brackets on theright and left side of the burner box andremove the sealed rangetop. Reinstall in thereverse order and check the gas connection forleaks.

TROUBLE S H O OT I N G

IMPORTANT NOTE: If the sealed rangetopdoes not operate properly, follow these trou-bleshooting steps:

Verify that power is being supplied to thesealed rangetop.

Check that gas valves are turned to the ONposition.

Check the gas supply and electricalconnections to ensure that the installationhas been completed correctly.

Follow troubleshooting procedures asdescribed in the Wolf Sealed Burner Rangetops Use & Care Information.

If the sealed rangetop still does not work,contact a Wolf authorized service center. Donot attempt to repair the sealed rangetopyourself. Wolf is not responsible for servicerequired to correct a faulty installation.

16

I F YO U N E E D S E RV I C E

For service in your area, contact either yourWolf dealer or visit the Showroom Locatorsection of our website, wolfappliance.comto find the regional distributor by country.

When calling for service, you will need thesealed rangetop model and serial numbers.Both numbers are listed on the rating plate,located on the underside of the sealedrangetop. Refer to the illustration on page 6for location of the rating plate.

I N S TA L LAT I ON I N S T R U C T I O N S

The information and images in this book are the copyright property of Wolf Appliance, Inc., anaffiliate of Sub-Zero, Inc. Neither this book nor anyinformation or images contained herein may becopied or used in whole or in part without theexpress written permission of Wolf Appliance,Inc.,an affiliate of Sub-Zero, Inc.

©Wolf Appliance, Inc. all rights reserved.

CONTACTINFORMATION

Sub-Zero Group Australia Pty Ltd

Level 10, 469 La Trobe Street

Melbourne Victoria 3000

Phone 03 9600 2218

subzero-wolf.com.au

ICB Sealed Burner Rangetop (ICBSRT) SeriesICB Sealed Burner Rangetop (ICBSRT) SeriesWiring Diagrams

7-2#820376 ­ Revision A ­ October, 2011

SW

1S

W2

SW

3S

W4

SW

5S

W6

LIN

EN

OT

US

ED

NE

UT

RA

LG

ND

GA

S V

ALV

E

NO

T U

SE

DN

OT

US

ED

GA

S V

ALV

E

S1

S2

S3

S4

CN

TR

L, IG

NT

R,

VA

LVE

4 P

T

LEF

T R

EA

RS

1

LEF

T F

RO

NT

S2

RIG

HT

RE

AR

S3

RIG

HT

FR

ON

T

S4

LEFT REARSWITCH SW1

LEFT FRONTSWITCH SW2

RIGHT FRONTSWITCH SW4

RIGHT REARSWITCH SW3

10 VDC SOLENOID

SP

AR

KE

R W

IRE

SP

AR

KE

R W

IRE

SP

AR

KE

R W

IRE

SP

AR

KE

R W

IRE

3-GRN/YLW

4-G

RN

/YLW

2-W

HT 1-B

LAC

K

6-O

RA

NG

E7-

OR

AN

GE

14-BLACK

8-B

LUE

9-B

LUE

10-B

LUE

11-B

LUE

5-WHITE

15-BLACK

16-B

LAC

K17

-BLA

CK

18-B

LAC

K

CA

PP

ED

CO

NN

EC

TO

R

GR

OU

ND

N IN

L1 IN

230V

50

CY

CLE

S

WIRING SCHEMATIC Model: ICBSRT304 - This wiring information is provided for use by qualified service personnel only.- Disconnect appliance from electrical supply before beginning service.- Be sure all grounding devices are connected when service is complete.- Failure to observe the above warnings may result in severe electrical shock.

Wiring DiagramsICB Sealed Burner Rangetop (ICBSRT) SeriesICB Sealed Burner Rangetop (ICBSRT) Series

7-7 #820376 ­ Revision A ­ October, 2011

2-W

HT

1-B

LK

8-B

LUE

9-B

LUE

29-B

LK26

-BLK

/OR

N

GR

IDD

LET

HE

RM

OS

TAT

2 VDCINDICATOR

LED

RIGHT REARSWITCH

SW3

11-B

LUE

RIGHT FRONTSWITCH

SW4

21-B

LK

10 VDCSOLENOID

7-ORN

230 V50 CYCLES

N IN

L1 IN

GR

OU

ND

3-GRN/YEL

6-ORN

RIG

HT

FR

ON

TS

4

RIG

HT

RE

AR

S3

GRIDDLEDIRECT

SPARK IGNITORMODULE

4-G

RN

/YE

L

NO

T U

SE

D

CO

NT

RO

L, IG

NT

R,

VA

LVE

5 P

T

NO

T U

SE

D

GA

S V

ALV

EG

AS

VA

LVE

GN

DN

EU

TR

AL

NO

T U

SE

DLI

NE

SW

6

SW

4S

W5

SW

3S

W2

SW

1

S5

S4

S3

S2

S1

SP

AR

KE

R W

IRE

18-B

LK

SP

AR

KE

R W

IRE

LEF

TR

EA

RS

1

SP

AR

KE

R W

IRE

LEFT FRONTSWITCH

SW2

17-B

LK

LEF

TF

RO

NT

S2

LFT REARSWITCH

SW1

16-BLK

5-WHT

14-BLK

15-BLK

27-G

RN

/YE

L

28-B

LK 25-W

HT

24-O

RN

10 VDCSOLENOID

23-O

RN

12345678910GND

SP

AR

K1

J4

SP

AR

KE

R W

IRE

CHARBROILERS5

SP

AR

KE

R W

IRE

SP

AR

KE

R W

IRE

DIRECT SPARKIGNITOR MODULE

CHARBRLRSWITCH

SW5

13-B

LUE

19-B

LK20

-BLK

10-B

LUE

CAPPERCONNECTORS

12-B

LUE

JUMPER

WIRING SCHEMATIC Model: ICBSRT484CG - This wiring information is provided for use by qualified service personnel only.- Disconnect appliance from electrical supply before beginning service.- Be sure all grounding devices are connected when service is complete.- Failure to observe the above warnings may result in severe electrical shock.

ICB Sealed Burner Rangetop (ICBSRT) SeriesWiring Diagrams

7-8#820376 - Revision A - October, 2011

NO

T U

SE

DN

OT

US

ED

GA

S V

ALV

EG

AS

VA

LVE

GN

DN

EU

TR

AL

NO

T U

SE

DLI

NE

SW

6

SW

4S

W5

SW

3S

W2

SW

1

S5

S4

S3

S2S1

17-B

LK

16-BLK

8-B

LUE

9-B

LUE

FRENCHTOPSWITCH

SW5

12-B

LUE

13-B

LUE

19-B

LK20

-BLK

RIGHT REARSWITCH

SW3

10-B

LUE

11-B

LUE

RIGHT FRONTSWITCH

SW4

21-B

LK

10 VDCSOLENOID

7-ORN

230 V50 CYCLES

N IN

L1 IN

GR

OU

ND 3-GRN/YEL

6-ORN

RIG

HT

FR

ON

TS

4

RIG

HT

RE

AR

S3

1-B

LK

2-W

HT

FRENCHTOPS5

4-G

RN

/YE

L

CO

NT

RO

L, IG

NT

R,

VA

LVE

5 P

TS

PA

RK

ER

WIR

E

18-B

LK

SP

AR

KE

R W

IRE

LEF

TR

EA

RS

1

SP

AR

KE

R W

IRE LEFT FRONT

SWITCHSW2

LEF

TF

RO

NT

S2

LEFT REARSWITCH

SW1

5-WHT

14-BLK15-BLK

SP

AR

KE

R W

IRE

SP

AR

KE

R W

IRE

JUMPER

CAPPERCONNECTORS

CA

PP

ER

CO

NN

EC

TO

RS

WIRING SCHEMATIC Model: ICBSRT484F - This wiring information is provided for use by qualified service personnel only.- Disconnect appliance from electrical supply before beginning service.- Be sure all grounding devices are connected when service is complete.- Failure to observe the above warnings may result in severe electrical shock.

74

M F 0 5 1

Sub-Zero Group Australia Pty Ltd

Level 10, 469 La Trobe Street

Melbourne Victoria 3000

Phone +61 3 9600 2218

subzero-wolf.com.au