SDMyers Carilec Transformer Maintenance and Reliability

25
Transformer Maintenance and Reliability Aris Peña, CRL Senior Business Development Manager

Transcript of SDMyers Carilec Transformer Maintenance and Reliability

Page 1: SDMyers Carilec Transformer Maintenance and Reliability

Transformer Maintenance

and Reliability

Aris Peña, CRL Senior Business Development

Manager

Page 2: SDMyers Carilec Transformer Maintenance and Reliability

• Introduction

• Maintenance, aging

and testing

• Life-extension services

• Moisture reduction

• Reliability

• Conclusions

Content Overview

Page 3: SDMyers Carilec Transformer Maintenance and Reliability

• Maintenance and reliability

are inseparable

• Influencing factors in

maintenance decisions

• Maintenance and monitoring

methods

Introduction

Page 4: SDMyers Carilec Transformer Maintenance and Reliability

Maintenance, Aging and Testing

Corrective Maintenance

Reacting to problems when they occur

Preventive Maintenance

Routine repairs and maintenance

Predictive Maintenance

Utilizes trending data for optimal performance

Page 5: SDMyers Carilec Transformer Maintenance and Reliability

Maintenance, Aging and Testing

Life of transformer = Life of paper

Oxidation attacks and

destroys paper

Page 6: SDMyers Carilec Transformer Maintenance and Reliability

Life-extension Services

Acid level in oil: Data from 5,000+ transformers

Non-serviced group: Elevated acid levels

Average acid level: 0.11 mg KOH/g

Serviced group: Oil reclamation had been performed

Average acid level: 0.03 mg KOH/g

Page 7: SDMyers Carilec Transformer Maintenance and Reliability

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0 10 20 30 40 50 60 70 80 90 100

Aci

d N

o. (m

g K

OH

/g)

Age (Years)

Acid Number as a function of Age(5,839 oil-filled transformers >500 kVA)

Non-serviced (1,675)

Serviced (4,164)

Page 8: SDMyers Carilec Transformer Maintenance and Reliability

Life-extension Services

Acids attack insulating paper

Insulating paper loses tensile strength

The paper is irreversibly weakened

WHEN PAPER STRENGTH

DECREASES, THE RISK

OF FAILURE INCREASES

Page 9: SDMyers Carilec Transformer Maintenance and Reliability

750x Magnification

Acid’s Effect on Paper: 0.05% Acid

Page 10: SDMyers Carilec Transformer Maintenance and Reliability

750x Magnification

Acid’s Effect on Paper: 0.30% Acid

Page 11: SDMyers Carilec Transformer Maintenance and Reliability

Life-extension Services

Study of 1,534 oil-filled transformers

Oil services include…

• Reclamation

• Moisture Reduction

• Oxidation Inhibitor Restoration

Page 12: SDMyers Carilec Transformer Maintenance and Reliability

Life-extension Services

Page 13: SDMyers Carilec Transformer Maintenance and Reliability

Moisture Reduction Passive online drying systems

Specs: 38,000 liters

Primary: 345 kVA

Secondary: 154 kVA

Duration: 12 months on 11 months off

Page 14: SDMyers Carilec Transformer Maintenance and Reliability

Reliability Looking to the future

A contingency plan is essential

• Spare transformer

• Double-connected

substation

• Available rental

• Mobile substation

Page 15: SDMyers Carilec Transformer Maintenance and Reliability

Reliability

Page 16: SDMyers Carilec Transformer Maintenance and Reliability

Reliability

Page 17: SDMyers Carilec Transformer Maintenance and Reliability

Reliability

Page 18: SDMyers Carilec Transformer Maintenance and Reliability

Reliability

Page 19: SDMyers Carilec Transformer Maintenance and Reliability

Reliability

Page 20: SDMyers Carilec Transformer Maintenance and Reliability

DGA Monitoring

Reliability

Page 21: SDMyers Carilec Transformer Maintenance and Reliability

• Degassing

• Removal of Acid and Sludge

• Moisture Reduction

• Processing | Equipment

• Fault Gas Monitoring

• Inspection and Repair

• Regasketing

• Full Electrical Testing

Reliability Actions Transformer PM and PdM Strategies

Page 22: SDMyers Carilec Transformer Maintenance and Reliability

DGA Monitoring

• 1-gas monitor

Hydrogen present in most faults

• 8-gas monitor

Very effective solution

Higher-budget applications

• Intuitive data presentation

• Complete data management system

Page 23: SDMyers Carilec Transformer Maintenance and Reliability

Data Management Transformer Dashboard®

Mechanical and

Maintenance

Fluid

Analysis

Health

Center

Monitor

Data

ET and IR

Data

Page 24: SDMyers Carilec Transformer Maintenance and Reliability

Assessing risk is essential to securing a

reliable electrical system

Aging infrastructure demands an ambitious

maintenance strategy

Proactive steps contribute to valuable

uptime and life extension

Conclusions

Page 25: SDMyers Carilec Transformer Maintenance and Reliability

Aris Peña Business Development

Representative

Thank you!