Script:-.Air Condition Script

download Script:-.Air Condition Script

of 11

Transcript of Script:-.Air Condition Script

  • 7/28/2019 Script:-.Air Condition Script

    1/11

    Air conditioningMarine air conditioning

    Marine air conditioner is also the same as the other conditioners available

    in today's market. It has bought a revolution in the air conditioning industry

    introducing one in the marine system.

    It involves almost in all the fields. Marine air systems are a leading supplier

    in the chilled water systems for more yachts on a worldwide basis.

    They are designed by the domestic environment corporation, which wasdeveloped by Taylor made group. Along with this marine chilled water

    system, domestic environmental corporation also launched its air

    conditioners and refrigerators.

    This uses the HVAC system of cooling the temperature. Domestic

    Corporation serves as one of the leading suppliers in accessory and airconditioning products. This also works same as the other conditioners. It

    also helps in controlling the temperature of the room and the humidity of

    the air.

  • 7/28/2019 Script:-.Air Condition Script

    2/11

    It maintains a constant temperature once it is regulated. This air conditioner

    almost works under the same mechanism and its components comprised in

    the central cooling unit.

    Advantages and disadvantages in marine air conditionersThere are both the advantage and the disadvantages with this system. The

    main advantage is that it is located in the less occupied areas and it

    requires no pipe line to connect with the other. This system is used for any

    size of boat or any size budget.

    It has made the marine air conditioners more adaptable and easy to install.

    This would be the smallest, lightest and the quietest conditioner in the

    market. It uses varies digital controls to keep track of the system. Marine air

    conditioning lowers the noise levels and it eliminates the zoning of central

    equipment.

    Marine air conditioning helps in controlling the temperature and to maintain

    the quality of the air. It works more than the other cooling central

    equipment. The total life cycle of the equipment is favorably more than the

    central equipment. It also cost less than other system.

    Air conditioningAir conditioning is the process of altering the properties of air. It is meant of

    human comfort. Air conditioning and ventilation is the simultaneous process

    of heating or cooling of air, humidity control as per human comfort, air

    filtration, air circulation and odor control

  • 7/28/2019 Script:-.Air Condition Script

    3/11

    AHU of ductable AC

    Air conditioning and refrigeration are provided through the removal of heat.

    Heat can be removed through radiation, convection, and by heat pumpsystems through the refrigeration cycle. Refrigeration conduction media

    such as water, air, ice, and chemicals are referred to as refrigerants.

    An air conditioning system, or a standalone air conditioner, provides

    cooling, ventilation, and humidity control for all or part of a building.

    The refrigeration cycle uses four essential elements to cool. The system

    refrigerant starts its cycle in a gaseous state. The compressor pumps the

    refrigerant gas up to a high pressure and temperature. From there it enters

    a heat exchanger (sometimes called a "condensing coil" or condenser)

    where it loses energy (heat) to the outside, cools, and condenses into its

    liquid phase. The liquid refrigerant is returned to another heat exchanger

    where it is allowed to evaporate; hence the heat exchanger is often called

    an "evaporating coil" or evaporator. A metering device regulates the

    refrigerant liquid to flow at the proper rate. As the liquid refrigerant

    evaporates it absorbs energy (heat) from the inside air, returns to the

    compressor, and repeats the cycle. In the process, heat is absorbed from

    indoors and transferred outdoors, resulting in cooling of the building.

    http://en.wikipedia.org/wiki/Thermal_radiationhttp://en.wikipedia.org/wiki/Convectionhttp://en.wikipedia.org/wiki/Heat_pumphttp://en.wikipedia.org/wiki/Heat_pumphttp://en.wikipedia.org/wiki/Refrigeration_cyclehttp://en.wikipedia.org/wiki/Refrigeranthttp://en.wikipedia.org/wiki/Air_conditionerhttp://en.wikipedia.org/wiki/Air_conditioning#Humidity_controlhttp://en.wikipedia.org/wiki/Air_conditioning#Humidity_controlhttp://en.wikipedia.org/wiki/Air_conditionerhttp://en.wikipedia.org/wiki/Refrigeranthttp://en.wikipedia.org/wiki/Refrigeration_cyclehttp://en.wikipedia.org/wiki/Heat_pumphttp://en.wikipedia.org/wiki/Convectionhttp://en.wikipedia.org/wiki/Thermal_radiation
  • 7/28/2019 Script:-.Air Condition Script

    4/11

    In variable climates, the system may include a reversing valve that

    switches from heating in winter to cooling in summer. By reversing the flow

    of refrigerant, the heat pump refrigeration cycle is changed from cooling to

    heating or vice versa. This allows a facility to be heated and cooled by a

    single piece of equipment by the same means, and with the same

    hardware.

    Central, 'all-air' air conditioning systems (or package systems) with a

    combined outdoor condenser/evaporator unit are often installed in modern

    residences, offices, and public buildings, but are difficult to retrofit (install in

    a building that was not designed to receive it) because of the bulky air

    ducts required.

    An alternative to central systems is the use of separate indoor and outdoor

    coils in split systems. These systems, although most often seen in

    residential applications, are gaining popularity in small commercial

    buildings. The evaporator coil is connected to a remote condenser unit

    using refrigerant piping between an indoor and outdoor unit instead of

    ducting air directly from the outdoor unit. Indoor units with directional vents

    mount onto walls, suspended from ceilings, or fit into the ceiling. Other

    indoor units mount inside the ceiling cavity, so that short lengths of duct

    handle air from the indoor unit to vents or diffusers around the rooms.

    Dehumidification (air drying) in an air conditioning system is provided by

    the evaporator. Since the evaporator operates at a temperature below dew

    point, moisture in the air condenses on the evaporator coil tubes. This

    moisture is collected at the bottom of the evaporator in a pan and removed

    by piping to a central drain or onto the ground outside. A dehumidifieris an

    http://en.wikipedia.org/wiki/Reversing_valvehttp://en.wikipedia.org/wiki/Dew_pointhttp://en.wikipedia.org/wiki/Dew_pointhttp://en.wikipedia.org/wiki/Dehumidifierhttp://en.wikipedia.org/wiki/Dehumidifierhttp://en.wikipedia.org/wiki/Dew_pointhttp://en.wikipedia.org/wiki/Dew_pointhttp://en.wikipedia.org/wiki/Reversing_valve
  • 7/28/2019 Script:-.Air Condition Script

    5/11

    air-conditioner-like device that controls the humidity of a room or building. It

    is often employed in basements which have a higherrelative

    humidity because of their lower temperature (and propensity for damp

    floors and walls). In food retailing establishments, large open chiller

    cabinets are highly effective at dehumidifying the internal air. Conversely, a

    humidifier increases the humidity of a building.

    Air conditioned buildings often have sealed windows, because open

    windows would work against an HVAC system intended to maintain

    constant indoor air conditions.

    All modern air conditioning systems, even small window package units, are

    equipped with internal air filters. These are generally of a lightweight gauzy

    material, and must be replaced or washed as conditions warrant. For

    example, a building in a high dust environment, or a home with furry pets,

    will need to have the filters changed more often than buildings without

    these dirt loads. Failure to replace these filters as needed will contribute to

    a lower heat exchange rate, resulting in wasted energy, shortened

    equipment life, and higher energy bills; low air flow can result in "iced-up"

    or "iced-over" evaporator coils, which can completely stop air flow.

    Additionally, very dirty or plugged filters can cause overheating during a

    heating cycle, and can result in damage to the system or even fire.

    Because an air conditioner moves heat between the indoor coil and the

    outdoor coil, both must be kept clean. This means that, in addition to

    replacing the air filter at the evaporator coil, it is also necessary to regularly

    clean the condenser coil. Failure to keep the condenser clean will

    eventually result in harm to the compressor, because the condenser coil is

    http://en.wikipedia.org/wiki/Relative_humidityhttp://en.wikipedia.org/wiki/Relative_humidityhttp://en.wikipedia.org/wiki/Humidityhttp://en.wikipedia.org/wiki/Humidityhttp://en.wikipedia.org/wiki/Relative_humidityhttp://en.wikipedia.org/wiki/Relative_humidity
  • 7/28/2019 Script:-.Air Condition Script

    6/11

    responsible for discharging both the indoor heat (as picked up by the

    evaporator) and the heat generated by the electric motor driving the

    compressor.

    Outside, fresh air is generally drawn into the system by a vent into the

    indoor heat exchanger section, creating positive air pressure. The

    percentage of return air made up of fresh air can usually be manipulated by

    adjusting the opening of this vent.

    Heat pumpIt is a reversible device that does mechanical work to extract heat from a

    cooler place and deliver heat to a warmer place. The heat delivered to the

    warmer place is, approximately, the sum of the original heat and the work

    done. Greater temperature differences between the warm and cold regions

    require greater amounts of work. In warm weather the heat pump acts like

    a traditional air conditioner, removing heat from the indoors and delivering

    heat to the outdoors. In cool weather, it removes heat from the outdoors

    and delivers heat to the indoors. The efficiency of a heat pump as a heating

    device depends upon the outdoor temperature. At 50F; (10C;) a heat

    pump is more efficient than a traditional heating system. Below 32F; (0C;)

    it is less efficient and requires augmenting with conventional heaters.

    In the construction of office buildings in the United States, air-conditioning

    systems are commonly included as integral parts of the structure. First

    used c.1900 in the textile industry, air conditioning found little use outside

    factories until the late 1920s. It is of great importance in chemical,

  • 7/28/2019 Script:-.Air Condition Script

    7/11

    pharmaceutical and other industrial plants where air contamination,

    humidity, and temperature affect manufacturing processes.

    Dew point temperature (DPT)It is that temperature at which a moist air sample atthe same pressure would

    reach water vapor saturation. At this saturation point,water vapor would begin to

    condense into liquid water fog or (if below freezing)solid hoarfrost, as heat

    is removed. The dew point temperature is measured easilyand provides

    useful information, but is normally not considered an independentproperty. It

    duplicates information available via other humidity properties and thesaturation

    curve.

    Tonnage of refrigerationIt is the amount of heat required to change one matric ton of water to ice in

    24 hours

    1 TR = 12000 btu/hr = 3000kcal/hr BTU (British thermal unit)

    Refrigeration cycle

  • 7/28/2019 Script:-.Air Condition Script

    8/11

    Diagram of a refrigeration cycleconsisting of

    1) Condensing coil

    2) Expansion valve3) Evaporator coil4) Compressor

    Relative Humidity (RH)It is the ratio of the mole fraction of water vapor to the mole fraction of

    saturated moist air at the same temperature and pressure. RH is

    dimensionless, and is usually expressed as a percentage. Lines of constant RH

    Reflect the physics of air and water: they are determined via experimental

    measurement. Note: the notion that air "holds" moisture, or that moisture

    dissolves in dry air and saturates the solution at some proportion, is an erroneous

    concept

    Humidity Ratio

    It is the proportion of mass of water vapor per unit mass of dry air at the

    given conditions (DBT, WBT, DPT, RH, etc.). It is typically the ordinate or

    vertical axis of the graph. For a given DBT there will be a particular

    humidity ratio for which the air sample is at 100% relative humidity: the

    relationship reflects the physics of water and air and must be measured.

    Humidity Ratio is dimensionless, but is sometimes expressed as grams of

    water per kilogram of dry air or grains of water per pound of air.

  • 7/28/2019 Script:-.Air Condition Script

    9/11

    Air conditioner maintain the humidity,temp,pressure,sound,air velocity,dust

    control. If we have to maintain more than 2-4 rooms at a time with one airconditioner then we are using this type of air conditioner. In this system one ductor line have to go through all rooms to flow the pure & cooled air to the rooms &

    one duct or line have to bring all corrosive air outside the rooms & flows intooutwards. This type of conditioner called ductable air conditioner.

    Chilled water air conditioner

    Chilled water air conditioning systems are commonly used in applications

    that need large cooling capacity such as hypermarket, industrial process,commercial air conditioning such as offices and factories. More and more homes

    are using this system to air conditioned their entire house because of its cost-effectiveness and no hazard of having refrigerant piped all over the house. Chiller

    is used to remove heat from the water which is then circulated through othercomponents to absorb heat from the space.

    Cooling tower

    In most chiller applications, a water-cooled condenser uses a cooling tower to

    reduce the temperature of the condenser. The water is then sent to the coolingtower by the use of a pump to be cooled by evaporation of the water in the coolingtower.

  • 7/28/2019 Script:-.Air Condition Script

    10/11

    Air cooled chiller

    A chiller is a machine that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. This liquid can then be circulated

    through a heat exchanger to cool air or equipment as required. In air conditioning

    systems, chilled water is typically distributed to heat exchangers, orcoils, in airhandling units or other types of terminal devices which cool the air in their

    respective space(s), and then the water is re-circulated back to the chiller to becooled again.

    Advantages of marine air conditioners

    It is located in the less occupied areas and it requires no pipe lines to connectwith the other.

    This would be the smallest, lightest and the quietest conditioner in themarket.

    This system can be used for any size of the boat and it has made the marineair conditioners more adaptable and easy to install.

    Marine air conditioners lowers the noise level and it eliminates the zoning ofcentral equipment.

    It helps in controlling the temperature and to maintain the quality of the air. Works more than other cooling central equipment. Total life cycle of the equipment is favorable more than the central

    equipment.

    It costs less than other systems.

  • 7/28/2019 Script:-.Air Condition Script

    11/11

    Submitted byNiaz v shanavaz