Scott Wireframe SCBA: End User Training -...

25
Scott Wireframe SCBA: End User Training

Transcript of Scott Wireframe SCBA: End User Training -...

Page 1: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Scott Wireframe

SCBA: End User

Training

Page 2: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Objective: • Give end users of the Scott Safety

Wireframe SCBA adequate knowledge of SCBA: o Components o Operation: Donning & Doffing o Maintenance & Inspection

Page 3: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

This training does not supersede users reading product information and manuals that are received with these products.

Be sure to consult your department or organizational guidelines in the operation of these products.

Page 4: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Know your SCBA: • Wireframe Airpack with Kevlar Straps • High Pressure Hose Coupling • Pressure Reducer • RIC UAC – Rapid Intervention Company

Universal Air Connection • Pak Alert & Pak Tracker Module • Control Console • E-Z Flo Plus Regulator • Regulator Quick Disconnect

Page 5: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak
Page 6: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Kevlar Straps

Control Console

Pak Alert/Pak

Tracker

High Pressure

Hose Coupling

RIC UAC

E-Z Flo

Plus

Regulator

Quick

Disconnect Pressure Reducer

Page 7: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Control Console

Manual Pak Alert

Activation

Multi-Function Button

Indicator Lights

Remote

Pressure Gauge

Page 8: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

E-Z Flo Plus Regulator

E-Z Flo Air

Saver Switch

Regulator Release Tab

Purge Valve

HUD

Regulator Gasket

Page 9: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Pak Alert/Pak Tracker

Pak Tracker and Pass

Alert Module

Module Battery

Compartment

(6 AA Batteries)

Page 10: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

RIC UAC: More on this connection port will be discussed in the RIT Pack Presentation.

RIC UAC without

Cover On

Page 11: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Heads Up Display (HUD): allows for continuous monitoring of air supply:

o At full air supply – 2 green lights o At ¾ air supply – 1 green light o At ½ air supply – 1 yellow flashing light o At ¼ air supply – 1 red flashing light with

vibra-alert activation o Orange light on the right of HUD will flash

only when the HUD batteries are low • 6 AA batteries = approximately 80 hrs. of

service life

Page 12: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Donning • Ensure all straps are fully extended and not tangled • Place SCBA on the ground (or hold in front of your

body while standing), cylinder down, harness up, with cylinder valve away from body

• Open cylinder valve completely (you should hear 3 chirps to indicate your SCBA is on)

• Grasp Wireframe at the center with both hands • Lift SCBA above head and bend forward • Lay SCBA on back, with arms inside shoulder straps • Tighten shoulder straps down as you straighten up • Fasten waist strap and adjust to your waist size

Page 13: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Donning (Cont’d) • Don your AV-Series mask • Slide hood over mask and put helmet on • Hold regulator with red purge valve at the 12 o’clock

position over your mask • Place regulator over mask and make quarter turn

counterclockwise until regulator tab clicks in • Take one rapid breath to begin air flow and then

begin breathing normally • Ensure HUD indicator lights are on and displaying 2

green lights (if cylinder is full)

Page 14: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Doffing • Remove regulator from your facepiece by using release

tab and depressing saver switch simultaneously • Fully extend all straps (shoulder and waist) • Unclip waist strap and remove from shoulders • Turn off cylinder valve completely • Bleed all air from the system by opening purge valve

(keep open until vibra-alert briefly activates) • Press yellow multi-function button on control console

twice to turn unit off (you may hear a few chirps before unit beeps to indicate it is off)

• If the unit does not turn off ensure cylinder valve is closed and all air is truly relieved from the system

Page 15: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Maintenance: General End User Maintenance • Changing batteries

o Turn screw in battery cover counterclockwise o Remove cover (screw will remain set in cover) o Remove all old batteries and replace with new

ones o Once batteries are replaced and cover is

re-secured, turn on airpack to inspect that HUD is functioning

Page 16: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Maintenance (cont’d): • Ensure coupling gasket is in place and replace as

needed • Clean all components with manufacturer

recommended cleaning components

Page 17: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection: • Inspect harness and wireframe (look for warn or

fraying straps) • Inspect your AV-series facepiece for cracks in the lens

or in the face seal and missing components (check nose seal, voicemitters, head harness, etc.)

• Inspect cylinder: o 1st remove cylinder from Airpack o Check hydro date (5 years on Carbon Fiber),

inspect valve, threads, gauge and outside wrap for cuts, deformities, etc.

Page 18: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Place cylinder back in airpack to continue inspection • Begin with E-Z Flo regulator:

o Check for deformities throughout regulator and hose

o Ensure purge valve is off o Ensure air saver switch is depressed o Connect regulator to a facepiece

• Remove regulator quick disconnect hose coupling and then reconnect to ensure ease of connection point

Page 19: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Before turning on the airpack, activate manual pak

alert by hitting red button once to ensure it is functional (hit yellow button twice to clear)

• Inspect control console and cables for cracks or breaks

• Check battery level: o Press and hold yellow multi-function button o If a green button flashes on control console

batteries check okay o If the light is red or does not display, batteries do

not have sufficient power

Page 20: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Open cylinder valve while listening and looking for

the following: o Regulator vibra alert alarm (short activation) o Pack alert will sound 3 short chirps o All 5 lights on HUD will illuminate

• Check Control Console to ensure: o Gauge is reading at full o Green light is flashing

Page 21: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Connect regulator to facepiece and check the

following: o Place mask to face and inhale sharply to begin

breathing air o Press air saver switch and remove from face o Check purge valve to ensure air will flow freely

Page 22: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Ensure HUD & vibra alert respond to no air:

o Shut down cylinder and place mask over face o breathe down all air in the system o HUD should respond to no air and vibra alert

should activate

Page 23: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Leave airpack motionless for 10 seconds to allow

pak alert to begin pre-alarm cycle, shake airpack to ensure motion will stop the alarm

• Again leave airpack motionless, now for 30 seconds, and allow pak alert to go into full alarm o Clear out this alarm by pressing yellow

multi-function button twice

Page 24: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak

Inspection (Cont’d): • Follow turn off instructions in the operation section

of this presentation • If any issues are found in performing your airpack

inspection tag the airpack as needing repair and ensure it is serviced by a Certified Scott Safety Technician

Page 25: Scott Wireframe SCBA: End User Training - AAAaaaemergency.com/wp-content/uploads/2014/03/Scott-Safety... · 2018. 3. 4. · • Leave airpack motionless for 10 seconds to allow pak