Scheda Essential 0914 - Zeppelin Medical€¦ · In respects of Directive 93/42/CEE and s.a.a....

2
Bisturi a Risonanza Quantica Molecolare Ricerca e sviluppo al servizio del benessere Quantum Molecular Resonance Generator Research and development for your health ESSENTIAL

Transcript of Scheda Essential 0914 - Zeppelin Medical€¦ · In respects of Directive 93/42/CEE and s.a.a....

Page 1: Scheda Essential 0914 - Zeppelin Medical€¦ · In respects of Directive 93/42/CEE and s.a.a. (2007/47/CE) and following international standards: IEC 60601-1, IEC 60601-1-2, IEC

Bisturi a Risonanza Quantica Molecolare

Ricerca e sviluppo al servizio del benessere

QuantumMolecular Resonance Generator

Research and developmentfor your health

ESSENTIAL

Page 2: Scheda Essential 0914 - Zeppelin Medical€¦ · In respects of Directive 93/42/CEE and s.a.a. (2007/47/CE) and following international standards: IEC 60601-1, IEC 60601-1-2, IEC

Via Leonardo Da Vinci, 1336066 Sandrigo (Vicenza) [email protected]. +39 0444 239519 | +39 0444 914173+39 0444 919400fax +39 0444 914319

EN ISO 13485: 2012EN ISO 9001: 2008

PATENTEDU.S. - E.P.

ww

w.te

leam

edic

al.c

omESSENTIAL

Rev

. 09/

14 -

IE

BISTURI A RISONANZA QUANTICA MOLECOLARELa tecnologiaESSENTIAL si basa sulla tecnologia della Risonanza Quantica Molecolare che genera campi elettrici in altafrequenza con una speciale combinazione di onde.Lo spettro ad alte frequenze quantizzate (4MHz con armoniche) genera quanti di energia in grado di rompere i legami molecolari a temperature minime. La coagulazione dei vasi sanguigni si ottiene attivando il processo naturale di denaturazione proteica del fibrinogeno, mantenendo la temperatura del tessuto circostante al di sotto dei 65°C.

Modalità bipolare Funzione di coagulo

VantaggiBassissima temperatura di lavoro Assenza di diffusione termica laterale Non necessita di irrigazione Assenza di escara Miglior cicatrizzazione del tessuto Completa assenza di stimolazioni neuromuscolari

Caratteristiche tecnicheConforme alla Direttiva 93/42/CEE e s.m.i. (2007/47/CE) e alle norme internazionali IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-2-2. Potenza in uscita: Coagulo bipolare 70W/25 Ω. Spettro di alte frequenze quantizzate: 4-8-12-16MHz. Due microprocessori per il controllo del sistema e dei circuiti di sicurezza. Autodiagnosi ad ogni accensione. Pedale di tipo elettrico.Apparecchio di classe I con parti applicate di tipo CF con circuito paziente isolato (flottante).

Essential è un prodotto brevettato da Telea Electronic Engineering s.r.l.

QUANTUM MOLECULAR RESONANCE GENERATORThe technologyESSENTIAL is based on the Quantum Molecular Resonance Technology which creates high frequency fields combined in such a peculiar way in order to minimaze the transfer of energy into a thermal form.The quantized high frequency spectrum (4MHz with harmonics) generates quanta of energy with a sufficient value to break up the molecular bonds without increasing the kinetic energy, inducing only a modest temperature increase. The coagulation of the blood vessels is achieved by activating the natural process of denaturation of the fibrinogen, while keeping the temperature of the surrounding tissue below 65 ° C.

Bipolar outputCoagulation function

AdvantagesVery low working temperature No lateral heat No irrigation needed No eschar Better healing of the tissue Total absence of neuromuscular stimulation

Technical featuresIn respects of Directive 93/42/CEE and s.a.a. (2007/47/CE) and following international standards: IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-2-2. Output power: Bipolar Coagulation 70W/25 Ω. Quantized high frequencies spectrum: 4-8-12-16MHz.Two microprocessors checking the system and the safety circuits. Autotest after every switch on. Electric pedal.Class I Equipment with type CF applied parts with isolated (floating) patient circuit.

Essential is a patented product by Telea Electronic Engineering s.r.l.

Codice/Ref. code: 2501029