High-Definition Digital Particle Size Analyzer
Saturn DigiSizer® II
Sensitivity, High Resolution, Reproducibility, Repeatability
Features
• Measuresbothorganicandinorganicparticlesrangingfrom40nanometersto2.5millimetersequivalentsphericaldiameter.
• CCDdetectorcontainsoverthreemilliondetectorelementsproducingextremelyhigh-resolutiondata.
• Adjustableliquidsamplehandlingunitforautomaticsampling,dilution,anddisper-sionisavailableinbothstandardandlow-volumeconfigurations.
• OnecomputercancontroluptotwoSaturnDigiSizerseachwithaliquidsamplehandlingunit.
• OptionalMasterTech052Autosamplerprovidesunattendedanalysisofupto18samples.
Saturn DigiSizer II High-Definition Digital Particle Size Analyzer
Major Advance in Particle Sizing Technology
Particlesizingtechniqueshaveadvancedsignificantlythroughoutthepastseveraldecades.Oneofthemostimportantcontributionstothisfieldistheapplicationoflaser-basedtechnologies,complementedwiththeuseofmodernphotodetectorsanddigitalcomputers.Forsometime,progressinlaserlightscatteringtechnologyhasledtofasteranalyses,butthequalityofthemeasurementwaslimited,oftenduetoinadquenciesinthedetector.Recognizingthisneedforbetterdetectioncapability,MicromeriticsdevelopedtheSaturnDigiSizer,aninstrumentthatemployedalaserdiodeandmoderncharge-coupleddevice(CCD)detectortosignificantlyimprovethesensitivity,resolution,reproducibility,andrepeatabilityofthelaserlightscatteringparticlesizingtechnique.
WiththeSaturnDigiSizerII,Micromeriticshasagainimprovedthisparticlesizetechnique.Utilizingastate-of-the-artCCDdetectorcontainingoverthreemilliondetectorelements,Mietheory,anduniquedesignanddatareductionfeatures,theSaturnDigiSizerIIgivesusersanextremelyhighlevelofresolutionandsensitivitynotavailableinotherlaserparticlesizingsystems.Thelevelofdetail,accuracy,andresolutionenablestheextractionofallavailableinformationfromthestaticlightscatteringpattern.Userscannowmeasurethesamematerialonmultipleinstrumentslocatedatdifferentlocationsaroundtheworldandgetthesame,highlydetailedsizedistributionmeasurementoneachinstrument.TheSaturnDigiSizerIIisfullyautomatedandrequireslittleoperatorintervention.
• Fast,detailedresultsarerepeatableon,andreproduciblebetween,everySaturnDigiSizerII.
• User-friendlyanalysisprogramincludeswizardsandintuitivescreensandisdesignedtooperateintheWindows®environment.
Cosmetics – Theappearance,application,andpackagingofcosmeticsareinfluencedbytheparticlesizedistributionofthebasepowders,suchastalc,andthepigmentsusedincoloring.
Abrasives–Performanceofabrasives,eitherinpowderformorafterbeingattachedtoabacking,isdictatedbythesizedistributionoftheabrasivepowder.Oversizedparticlesleadtoscratchingandgouging.Undersizedparticlesmayleadtocloggingoftheabrasivepapers.
Mining–Refiningefficiencyofmaterialsisrelatedstronglytotheparticlesizedistributionoftherawmineral.Forproductsthatareusedwithoutchemicalchange,thesizeofparticlestakenfromtheminemaybetoolargeforfinalusage.Analysesperformedontheextractedmineralswillhelpdeterminetheamountofsizereductionneededoncetheproductreachestheprocessingplant.
Column Packing Materials–Theback-pressureofthepackedbedwithinthecolumnisadirectfunctionofthesizeofthechannelsthroughthebedand,thus,thesizedistributionofthecolumnpackingmaterial.Oversizedparticlescreatevoidsinthebed,reducingefficiencyduetoremixingoftheseparatedsamplecomponents.Undersizedparticlesleadtoblockageofflowpathsthroughthebed,increasingtheback-pressureandanalysistime.Aproperdistributionleadstogreaterseparationefficiency.
Applications
Pharmaceuticals – Particlesizeplaysamajorroleintheabilitytoprocess,blend,tablet,andpackageadrugsubstance.Theusefulshelflifeanddissolutionrate(governinghowrapidlythemedicinebecomesavailabletothebody)dependupontheparticlesizeofthematerial.
Ceramics – ParticleSizeinformationhelpstodeterminecuringandbondingprocedures,controlporestructure,ensureadequategreenbodystrength,andproduceafinalproductofdesiredstrength,texture,appearance,anddensity.
Catalysts – Flowpropertiesoffluid-crackingcatalystsdependupontheparticlesizedistributionoftheparticles.Surfaceareaandporestructureofacidcatalystsandcatalystsupportsresultfromtheparticlesizedistributionoftheparticlesthatareusedtoproducethem.
Paints and Coatings – Theparticlesizedistributionofthepigmentorfillerinfluencestheporosity,gloss,texture,color,colorsaturation,brightness,solidscontent,andfilmadhesionproperties.Theresultingporositycancontrolapplicationpropertiessuchasfluidity,dryingorsettingtime,andfilmthickness.
Saturn DigiSizer II Advantages
✔ Superiorsensitivity
✔ Higherresolution
✔ Superioranalysis-to-analysisrepeatability
✔ Greateraccuracy
✔ Betterreproducibility
✔ Exceptionaldataquality
✔ Fullyautomatedsystem
✔ Versatilesamplehandlingoptions
✔ Easy-to-usesoftware
✔ 21CFRPart11softwareoption
✔ IQ/OQvalidationserviceoption
✔ Noproprietary“black-box”algorithms
Revolutionary Approach to Particle Sizing
Patented Optical Design
CCDswereoriginallydevelopedandusedforhigh-sensitivityandhigh-resolutionrequirementsofimagingforastronomy.TheSaturnDigiSizerIIcapturesthescatteringpatternusingapatentedopticaldesignthatemploysaCCDasthelightdetector.Ahigh-definitiondigitalrepresentationofthescatteringpattern,whichcontainsalloftheinformationrequiredtodeterminetheparticlesizedistribution,iscaptured.
Micromeritics’applicationoftheCCDarrayeliminatestheneedformechanicalfine-tuningofopticalalignment.Theinstrumentisautomaticallyalignedbyre-mappingtheCCDarraysothatthescatteringangleassignedtoeachelementisexacttolessthan0.005degreerelativetothecentral,unscatteredlightbeam.TheSaturnDigiSizerII’sCCDarrayhasmorethanthreemilliondetectorelements.Theresultingextremelyhighresolutionmakesitpossibletodetectsubtledifferencesinthescatteringpatternsand,therefore,subtledifferencesinparticlesizedistributions.Theseminutedifferencesinsampleparticlesizemayindicateamanufacturingvariance,corroborateorrefutetheoreticalstudies,orhelpexplainnaturalprocesses.Higherresolutionmeansgreaterknowledgeaboutdifferencesbetweensamples.
Advanced design features enable the Saturn DigiSizer to measure a light scattering pattern over a broad range of scattering angles with a dynamic intensity range from 1 to 1x1010. Combined with the high angular resolution of the CCD, the detector system provides an effective resolution of several million pixels at different positions in the scattering pattern, each detecting minute variations in light intensity. The Saturn DigiSizer’s high resolution enables the instrument to detect extremely small variations in the scattering pattern that are not detected by lower resolution instruments. It is this high level of accuracy that allows the Saturn DigiSizer to provide more detailed and precise particle size information than laser diffraction particle sizing systems of conventional design.The Saturn DigiSizer’s
high resolution enables the instrument to detect extremely small variations in the scattering pattern that are not detected by lower resolution instruments.
Micromeritics’ New Approach to an Old Technique
Theoriesconcerningtherelationshipbetweenanassemblageofparticlesandthepatternoflightitscatteredwereproposedinthe1800’s,mathematicallyunifiedbyMiein1908,andeloquentlysummarizedbyvandeHulstin1957.Bytheearly1970’s,laserlightscatteringparticlesizinginstrumentswerebecomingcommerciallyavailable.Amajorproblemwiththistechnique,evenupuntiltoday,hasbeenthelackofagreementbetweenanalysesofthesamesamplematerialbyinstrumentsfromdifferentmanufacturers,andevenbetweendifferentmodelsproducedbythesamemanufacturer.Thisisprimarilybecauseofmeasurementoftoofewdatapointsinthescatteringpatternandtheinadequateattemptstocompensateforlowresolutionandothershortcomingsusingsoftware-basedalgorithms.
Micromeriticshastakenanewandmoreeffectivedesignapproachtomeasuringthescatteringpattern.Ratherthanuseaphotodiodearraytocaptureaveragelightintensityreadingsoverextendedregionsofthescatteringpattern,theSaturnDigiSizerIIusesahigh-resolutionCCDarrayinastepwisemannertocaptureatruedigitalrepresentationofthescatteringpattern–notsimplythe50-or100-lightmeasurementswithinthepatternastakenwithnon-digitaltechniques.
Withthishigh-resolution,closelyspacedarrayofdata,theintensityversusangleplotofdataispracticallycontinuous.Thus,Mietheorycanbeapplieddirectly,withoutcompensationalgorithmsandwithoutconcernoverwhetherthedistributionismonomodalormultimodal.ThequalityoftheSaturnDigiSizerIIanalysisisapparentuponoverlayingtheangleversesintensityplotofexperimentaldatafromananalysisofareferencematerial(oramixtureofdifferentsizereferencematerials)withtheangleversusintensityplotofdatacalculatedfromMietheoryforthereferencesize(s).SuchacomparisonisastandardreportprovidedbytheSaturnDigiSizerII.
Superior Data Reduction and Reporting
Inaddition,Micromeritics’confirm™21CFRPart11softwareassistswithcompliancetoFDAregulations.CombinedwithMicromeritics’IQandOQservices,theusercanbeassuredthattheSaturnDigiSizerIIsystemisvalidatedforaccuracy,reliability,consistentperformance,andprovidessafeguardstoprotecttheintegrityofanalysisrecords.Systemaccessislimitedtoauthorizedindividuals.Secure,computer-generated,time-stampedaudittrailsareintegralpartsofthesoftwareprogram.
Wide Range of Data Presentation Options
Withmanyinstrumentsthatemploythestaticlightscatteringtechnique,afinalreportofreduceddatatypicallyistheonlyoutputavailable.TheSaturnDigiSizerII,however,allowsyoutoaccesstherawdata.Forinstance,animageofthescatteringpattern(2-Dand3-Drepresentations)canbedisplayed,oryoucanreceivea592-pointintensityversusangledatareportintabularorgraphicalform.Toallowaquickassessmentofthefitoftheoreticalmodelstoexperimentaldata,youalsocanobtainanoverlayplotofmeasureddatacalculatedfromMietheory.
TheSaturnDigiSizerII’spowerful,easy-to-useandversatileuserinterfaceprovidesalltheconvenientfeaturesyouexpectfromaWindows-basedprogramsuchaspoint-and-clickmenus,multitaskingcapability,copytoclipboard,andmore.ThefamiliarWindowsformatreducesthetimerequiredfortrainingandeliminatestheneedformostoff-linedatamanipulation,resultinginincreasedproductivity.TheanalysisprogramisdesignedtooperateintheWindowsenvironmentandincludeswizardsandintuitivescreensenablingyoutoperformsystemoperationsquicklyandefficiently.
This repeat analysis of a blend of 10 latex standards demonstrates the size resolution and repeatability of the calculated distribution.
This is an analysis of two narrow-distribution latex microspheres which differ in size by only 10%. Notice the baseline resolution.
The Goodness of Fit graph of a 102-µm latex standard shows the agreement between the calculated PSD and the measured light scattering data.
Typical histogram of a mixture of 50-, 80-, and 160-µm latex standards with cumulative size distribution.
Reduction of Raw Data Based on Mie Theory Ensures Exceptional Data Quality
MicromeriticsemploystheMietheory(ortheoperatorcanchoosetouseFraunhoferforparticlesthatarebothlargeandopaque)toreduceexperimentaldatausingawell-published,non-negativeleastsquaresmethod.Thesetheoriesdescribelightscatteringviatheoreticalmodels.NomodificationstothetheoryaremadewiththeSaturnDigiSizerII,andnoassumptionsofmodalityordistributiontypeareused.ThisismadepossiblebytheremarkablyhighresolutionoftheopticalsystemallowingverynarrowsizeclassestobeusedinfittingthedatatoMietheory.
TheapplicationofMietheoryprovidesunambiguoussizedata.Inadditiontoreportingthedata,theSaturnDigiSizerIIcangenerateaplotthatshowshowwellexperimentalmeasurementscomparewiththeoreticalMiecalculationsforthescatteringpatternfromthereporteddistribution.
Analysis of a blend of a sample of 44- to 53-µm glass beads and a sample of 125- to 149-µm glass beads.
This magnified view of the frequency distribution for the 5.010-µm latex standard demonstrates the remarkable repeatability of the Saturn DigiSizer II.
This PSD History chart of 94 analyses of garnet illustrates the reproducibility of the Saturn DigiSizer II.
Accessories
TheSaturnDigiSizerIISystemincludesmanyoptionsthatallowyoutotailoryourinstrumentaccordingtoyourspecificneeds.Multiplesampledispersionsystemoptions,anautomaticautosampler,andadeviceforremovingdissolvedgasesfromthesuspensionliquidareavailableandcontributetotheversatilityofthesystem.TheseoptionsarealldesignedandmanufacturedwiththesamecareandattentiontodetailthatproducedtheSaturnDigiSizer.
Liquid Sample Handling Units
TheSaturnDigiSizerII’ssamplehandlingunitensuresthateverysamplewillbecorrectlydispersed.Micromeritics’patented,state-of-the-artliquidsamplehandlingunits(LSHU)workwiththeinstrumentsoftwaretoassurethatsamplesuspensionisoftheproperconcentration.Acontinuousflowthroughthereservoirprovidesamixingactionsufficienttokeepallsamplematerialsuspendedandpreventsthesettlingofparticles.TheLSHUhasseveralautomatedfeaturessuchasabuilt-inultrasonicprobe,automaticliquidlevelcontrol,particleconcentrationdetection,andasamplecirculationsystemthatcontinuouslymaintainsdispersion.Auto-dispersionandauto-dilutionfeaturesmonitorthesample’sconcentrationandaddliquidasneededuntiloptimumconcentrationisobtained.
Toreducethepossibilityofsamplecarryoverbetweenanalyses,theLSHUhasapatentedreservoirrinsedesign.Whileotherdesignssimplyfillandemptythereservoirtorinse,theSaturnDigiSizer’sLSHUhasafeaturethatspraysthereservoirwallsasthefluidlevelrecedes.Thisremovesresiduethatotherwisemightclingtothesurface.
TheLSHUSystemisavailableintwoconfigurations,astandardversionandalow-volumeversion.MicromeriticscanhelpyoudeterminetheLSHUthatfitsyourspecificneeds.
Standard Liquid Sample Handling Unit
Thestandardunitincludesareservoirthatisadjustablebetween590to690mLofdispersedsamplewithacirculationpumprateof5–19Lperminute.Itcancirculateparticlesfrom0.04to2500µm.Thehighflowratebettersupportsparticlesthathaveaninherentlyhighersettlingvelocity.Inaddition,thehighersystemclearancehelpstoavoidattritionoftheparticlesduringcirculation.
Applications:
• Coarseparticles
• High-densityparticles
• Quantityofsample,liquidsupplyand/orwastedisposalisnotaproblem
Low-Volume Liquid Sample Handling Unit
Thelow-volumeunitincludesareservoirthatisadjustablebetween100to120mLofdispersedsamplewithacirculationpumprateof2–12Lperminute.Itcancirculateparticlesfrom0.04to750µmindiameter.Thelow-volumeliquidsamplehandlingunitreducescostbyusingsmalleramountsofsample,andreducestheexpenseofwastedisposal.
Applications:
• Samplequantityislimited
• Supplyofdispersionliquidislimitedand/orexpensive
• Dispersionliquidmaybehazardoustouseand/ormakedisposaldifficult
AquaPrep™
Whenusingwaterasasuspensionliquidduringparticlesizeanalysis,itispossibleforatmosphericgasestobereleasedfromsolutionformingminutebubblesthatbecomeincorporatedwiththesampledispersion.Thishasadisruptiveeffectonparticlesizeanalysisbecausethebubblescirculatethroughthemeasurementzoneoftheanalyzerandaredetectedasiftheywereparticles.Thiscanresultinthereportingofparticlesizeclassesthatarenotactuallypresent.Removingthesebubblesisrequiredforobtainingthemostaccurateparticlesizedata,particularlywhenusingahighlysensitiveanalyzerliketheSaturnDigiSizerII.Micromeritics’AquaPrepsolvesthisproblembyrecirculatingwaterthroughahydrophobiccapsuleconsistingofmanythin-walledcapillaries.Avacuumpumpprovideslowpressureontheoutsideofthecapillaries.Theresultisadiffusionofdissolvedairfromthewaterthroughthecapillarywallsandremovalthroughthevacuumpump.
TheAquaPrepcanprepare10litersofwaterinlessthan2hours(atstandardtemperatureandpressure)andensuresthatyouobtainthemostaccuraterepresentationpossibleoftheparticlesizedistributioninyoursample.
MasterTech™ Autosampler
TheMasterTechAutosamplerprovidesassurancethatallsamplesarepreparedandanalyzedexactlythesameway.TheMasterTechisdesignedtoincreasethroughput,repeatability,andreproducibilitywhilereducingoperatorinvolvement.Upto18samplescanbequeuedtorunsequentiallyandcompletelyunattended,includingautomaticstirringorsonicationpriortotransfertotheanalysissystem.TheSaturnDigiSizerII’soperatingsoftwarecontrolstheMasterTech,andinformationaboutdispersionisstoredinthesamplefileforfuturereference.
TheMasterTechfeaturesapowerfulultrasonicprobeforsampledispersion.Powertotheprobetipisadjustableandthedrivingcircuitisself-tuningformaintainingefficientandconsistentsonicenergylevels.Afront-paneldigitalreadoutletsyouknowwhenthedesiredpowerisreached,andthatsamepowerisappliedeachtimethemethodisrepeated.
To request a quote or additional product information, visit Micromeritics’ web site at www.micromeritics.com, contact your local Micromeritics sales representative, or our Customer Service Department at (770) 662-3636.
Windows is a registered trademark ofMicrosoft Corporation.
Micromeritics Instrument Corporation4356 Communications Drive Norcross, GA 30093 USATelephones:U.S. Sales (770) 662-3633International Sales (770) 662-3660Fax (770) 662-3696
Micromeritics ChinaNo. 1025 Jiahui YuanHua-Ao (Epoch) CenterNo. 31 Zi Zhu Yuan RoadHai Dian DistrictBeijing 100089 P.R. CHINATelephone (+86) (0)10-6848-9371 or 72 (+86) (0)10-6848-9403Fax (+86) (0)10-6848-9371 or 72
Micromeritics European Technical CenterAvantis Science ParkRutherford 108D-52072 AachenGERMANYTelephone (+49) (0)241-189-446-0Fax (+49) (0)241-189-446-11
Micromeritics GmbHAvantis Science ParkRutherford 108D-52072 AachenGERMANYTelephone (+49) (0)241-189-446-0Fax (+49) (0)241-189-446-11
Micromeritics Ltd.Unit 2, Chestnut House178-182 High Street NorthDunstable, Bedfordshire LU6 1AT ENGLANDTelephone (+44) (0)1582-475248Fax (+44) (0)1582-475252
Micromeritics N.V./S.A.Eugene Plaskylaan 140B1030 Brussels BELGIUMTelephone (+32) (0)2-743-39-74Fax (+32) (0)2-743-39-79
Micromeritics SRLVia W. Tobagi n. 26/720068 Peschiera BorromeoMilano ITALYTelephone (+39) (0)2 553 02833Fax (+39) (0)2 553 02843
Micromeritics France S.A.Parc AlataRue Antoine Laurent LavoisierF-60550 Verneuil-en-HalatteFRANCETelephone (+33) (0)3-44-64-60-80Fax (+33) (0)3-44-64-60-89
For additional product and materials analysis service details visit