Page 1 of 114 SAR Test Report Report No.: AGC00377160401EH01 PRODUCT DESIGNATION : Smart Phone BRAND NAME : CUBOT MODEL NAME : RAINBOW CLIENT : Shenzhen Huafurui Technology Co., Ltd. DATE OF ISSUE : Apr. 28,2016 STANDARD(S) : EN 50360:2001+A1:2012; EN 62209-1: 2006; IEC 62209-1: 2005; EN 62209-2:2010; IEC 62209-2:2010; EN 50566:2013 ; REPORT VERSION : V1.0 Attestation of Global Compliance(Shenzhen) Co., Ltd. CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context.

Transcript of SAR Test Report - CUBOT · SAR Test Report Report No.: AGC00377160401EH01 PRODUCT DESIGNATION : ......

Page 1 of 114

SAR Test Report

Report No.: AGC00377160401EH01

PRODUCT DESIGNATION : Smart Phone

BRAND NAME : CUBOT

MODEL NAME : RAINBOW

CLIENT : Shenzhen Huafurui Technology Co., Ltd.

DATE OF ISSUE : Apr. 28,2016

STANDARD(S) : EN 50360:2001+A1:2012; EN 62209-1: 2006; IEC 62209-1: 2005; EN 62209-2:2010; IEC 62209-2:2010; EN 50566:2013 ;

REPORT VERSION : V1.0

Attestation of Global Compliance(Shenzhen) Co., Ltd.

CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context.

Report No.: AGC00377160401EH01 Page 2 of 114

Report Revise Record

Report Version Revise Time Issued Date Valid Version Notes

V1.0 / Apr. 28,2016 Valid Original Report

Report No.: AGC00377160401EH01 Page 3 of 114

Test Report Certification Applicant Name Shenzhen Huafurui Technology Co., Ltd.

Applicant Address Room 07B,Tower A, Modern Window Building, Huaqiang North Road, Futian District, Shenzhen, P.R. China

Manufacturer Name Shenzhen Huafurui Technology Co., Ltd.

Manufacturer Address Room 07B,Tower A, Modern Window Building, Huaqiang North Road, Futian District, Shenzhen, P.R. China

Product Designation Smart Phone

Brand Name CUBOT

Model Name RAINBOW

Different Description N/A

EUT Voltage DC3.8V by battery

Applicable Standard EN 50360:2001+A1:2012; EN 62209-1: 2006; IEC 62209-1: 2005;

EN 62209-2:2010; IEC 62209-2:2010; EN 50566:2013;

Test Date Apr. 21,2016 to Apr. 25,2016

Performed Location Attestation of Global Compliance(Shenzhen) Co., Ltd.

2 F, Building 2, No.1-No.4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang Street, Bao'an District, Shenzhen, China

Report Template AGCRT-EC-3G/SAR (2016-01-01)

Tested By

Bobby wang(Wang Zhicheng)

Apr. 28,2016

Checked By

Angela Li(Li Jiao)

Apr. 28,2016

Authorized By

Solger Zhang(Zhang Hongyi)

Authorized Officer Apr. 28,2016

Report No.: AGC00377160401EH01 Page 4 of 114

TABLE OF CONTENTS

1. SUMMARY OF MAXIMUM SAR VALUE ....................................................................................................... 5

2. GENERAL INFORMATION ............................................................................................................................ 6

2.1. EUT DESCRIPTION ...................................................................................................................................... 6

3. SAR MEASUREMENT SYSTEM ..................................................................................................................... 8

3.1. THE DASY5 SYSTEM USED FOR PERFORMING COMPLIANCE TESTS CONSISTS OF FOLLOWING ITEMS.................... 8 3.2. DASY5 E-FIELD PROBE .............................................................................................................................. 9 3.3. DATA ACQUISITION ELECTRONICS DESCRIPTION ............................................................................................. 9 3.4. ROBOT ..................................................................................................................................................... 10 3.5. LIGHT BEAM UNIT ..................................................................................................................................... 10 3.6. DEVICE HOLDER ........................................................................................................................................ 11 3.7. MEASUREMENT SERVER ............................................................................................................................. 11 3.8. PHANTOM .............................................................................................................................................. 12

4. SAR MEASUREMENT PROCEDURE .......................................................................................................... 13

4.1. SPECIFIC ABSORPTION RATE (SAR) ........................................................................................................... 13 4.2. SAR MEASUREMENT PROCEDURE ............................................................................................................. 14

5. TISSUE SIMULATING LIQUID ..................................................................................................................... 15

5.1. THE COMPOSITION OF THE TISSUE SIMULATING LIQUID ................................................................................... 15 5.2. TISSUE DIELECTRIC PARAMETERS FOR HEAD AND BODY PHANTOMS .............................................................. 15 5.3. TISSUE CALIBRATION RESULT ..................................................................................................................... 16

6. SAR SYSTEM CHECK PROCEDURE ......................................................................................................... 17

6.1. SAR SYSTEM CHECK PROCEDURES ........................................................................................................... 17 6.2. SAR SYSTEM CHECK ................................................................................................................................ 18

7. EUT TEST POSITION ................................................................................................................................... 20

7.1. DEFINE TWO IMAGINARY LINES ON THE HANDSET ......................................................................................... 20 7.2. CHEEK POSITION ...................................................................................................................................... 21 7.3. TILT POSITION ........................................................................................................................................... 21 7.4. BODY WORN POSITION .............................................................................................................................. 22

8. SAR EXPOSURE LIMITS ............................................................................................................................ 23

9. TEST EQUIPMENT LIST ............................................................................................................................. 24

10. MEASUREMENT UNCERTAINTY .............................................................................................................. 25

11. CONDUCTED POWER MEASUREMENT .................................................................................................. 28

12. TEST RESULTS ........................................................................................................................................ 36

12.1. SAR TEST RESULTS SUMMARY ................................................................................................................ 36

APPENDIX A. SAR SYSTEM CHECK DATA ................................................................................................... 45

APPENDIX B. SAR MEASUREMENT DATA.................................................................................................... 49

APPENDIX C. TEST SETUP PHOTOGRAPHS &EUT PHOTOGRAPHS ...................................................... 114

APPENDIX D. CALIBRATION DATA ............................................................................................................. 114

Report No.: AGC00377160401EH01 Page 5 of 114

1. SUMMARY OF MAXIMUM SAR VALUE The maximum results of Specific Absorption Rate (SAR) found during testing for EUT are as follows:

Frequency Band Highest Reported 10g-SAR(W/Kg) SAR Test Limit

(W/Kg) Head Body-worn(with 5mm separation)

GSM 900 0.429 0.900

2.0

DCS 1800 0.192 0.926

WCDMA Band I 0.177 1.291

WCDMA Band VIII 0.274 0.378

WIFI 2.4G 0.298 0.200

Simultaneous Reported SAR

1.458

SAR Test Result PASS

This device is compliance with Specific Absorption Rate (SAR) for general population/uncontrolled exposure limits (2.0W/Kg).

Report No.: AGC00377160401EH01 Page 6 of 114

2. GENERAL INFORMATION

2.1. EUT Description

General Information

Product Designation Smart Phone

Test Model RAINBOW

Hardware Version W363_MB_V1.1

Software Version N/A

Device Category Portable

RF Exposure Environment Uncontrolled

Antenna Type Internal

GSM and GPRS&EGPRS

Support Band GSM 850 GSM 900 DCS 1800 PCS 1900

GPRS & EGPRS Type Class B

GPRS & EGPRS Class Class 12(1Tx+4Rx, 2Tx+3Rx, 3Tx+2Rx, 4Tx+1Rx)

TX Frequency Range GSM900:880-915MHz ; DCS1800:1710-1785MHz

RX Frequency Range GSM900:925-960MHz ; DCS1800:1805-1880MHz

Release Version R99

Type of modulation GMSK for GSM/GPRS; GMSK & 8-PSK for EGPRS

Antenna Gain GSM900: -2.31dBi; DCS1800: 0.18dBi

Max. Average Power (Max. Peak Power)

GSM900:31.42dBm (31.63dBm) DCS1800:28.38dBm (28.56dBm)

Bluetooth

Bluetooth Version V2.0 V2.1 V2.1+EDR V3.0 V3.0+HS V4.0

Operation Frequency 2402~2480MHz

Type of modulation GFSK ∏/4-DQPSK 8-DPSK

EIRP 0.53dBm

Antenna Gain -3.27dBi

Report No.: AGC00377160401EH01 Page 7 of 114

EUT Description( Continue)

WCDMA

Support Band UMTS FDD Band I UMTS FDD Band VIII UMTS FDD Band II UMTS FDD Band V

HS Type HSPA(HSUPA/HSDPA)

TX Frequency Range FDD Band I : 1920-1980MHz; FDD Band VIII : 880-915MHz

RX Frequency Range FDD Band I : 2110-2170MHz; FDD Band VIII : 925-960MHz

Release Version Rel-6

Type of modulation HSDPA:QPSK/16QAM; HSUPA:BPSK; WCDMA:QPSK

Antenna Gain Band I: -0.17dBi ; Band VIII: -2.31dBi

Max. Average Power (Max. Peak Power)

Band I:23.93dBm (24.25dBm) Band VIII:23.37dBm (23.56dBm)

WIFI

WIFI Specification 802.11a 802.11b 802.11g 802.11n(20) 802.11n(40)

Operation Frequency 2412~2472MHz

EIRP 11b:10.71dBm,11g:7.78dBm,11n(20):7.92dBm,11n(40):7.31dBm

Antenna Gain -3.27dBi

Li-ion Battery

Brand Name CUBOT

Model Name RAINBOW

Manufacturer Name Zhongshan Tianmao Battery Co., Ltd.

Manufacturer Address No. 208, Qianjin 1st Road, Xinqianjin Village, Tanzhou Town, Zhongshan City

Capacitance 2200mAh

Rated Voltage/ Charging Voltage DC3.8V/ DC4.35V

Note: The sample used for testing is end product.

Report No.: AGC00377160401EH01 Page 8 of 114

3. SAR MEASUREMENT SYSTEM

3.1. The DASY5 system used for performing compliance tests consists of following items

˙A standard high precision 6-axis robot with controller, teach pendant and software.

˙Data acquisition electronics (DAE) which attached to the robot arm extension. The DAE consist of a highly

sensitive electrometer-grade preamplifier with auto-zeroing, a channel and gain-switching multiplexer, a fast 16 bit AD-converter and a command decoder with a control logic unit. Transmission to the measurement server is accomplished through an optical downlink for data and status information, as well as an optical uplink for commands and the clock

˙A dosimetric probe equipped with an optical surface detector system.

˙The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital

Communication to the DAE. To use optical surface detection, a special version of the EOC is required. The EOC signal is transmitted to the measurement server.

˙A Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.

˙A computer running WinXP and the DASY5 software.

˙Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.

˙Phantoms, device holders and other accessories according to the targeted measurement.

Report No.: AGC00377160401EH01 Page 9 of 114

3.2. DASY5 E-Field Probe

The SAR measurement is conducted with the dosimetric probe manufactured by SPEAG. The probe is specially designed and calibrated for use in liquid with high permittivity. The dosimetric probe has special calibration in liquid at different frequency. SPEAG conducts the probe calibration in compliance with international and national standards (e.g. IEEE 1528, EN62209, IEC 62209, etc.)Under ISO17025.The calibration data are in Appendix D.

Isotropic E-Field Probe Specification

Model ES3DV3

Manufacture SPEAG

frequency 0.15GHz-3 GHz Linearity:±0.2dB(150MHz-3 GHz)

Dynamic Range 0.01W/Kg-100W/Kg Linearity:±0.2dB

Dimensions

Overall length:337mm Tip diameter:4mm Typical distance from probe tip to dipole centers:2mm

Application

High precision dosimetric measurements in any exposure scenario (e.g., very strong gradient fields). Only probe which enables compliance testing for frequencies up to 3 GHz with precision of better 30%.

3.3. Data Acquisition Electronics description

The data acquisition electronics (DAE) consist if a highly sensitive electrometer-grade preamplifier with auto-zeroing, a channel and gain-switching multiplexer, a fast 16 bit AD-converte and a command decoder with a control logic unit. Transmission to the measurement sever is accomplished through an optical downlink fir data and status information, as well as an optical uplink for commands and the clock.

The mechanical probe mounting device includes two different sensor systems for frontal and sideways probe contacts. They are used for mechanical surface detection and probe collision detection.

DAE4

Input Impedance 200MOhm

The Inputs Symmetrical and floating

Common mode rejection above 80 dB

Report No.: AGC00377160401EH01 Page 10 of 114

3.4. Robot The DASY system uses the high precision robots (DASY5:TX60) type from Stäubli SA (France). For the 6-axis controller system, the robot controller version from is used. The XL robot series have many features that are important for our application: � High precision (repeatability 0.02 mm) � High reliability (industrial design) � Jerk-free straight movements � Low ELF interference (the closed metallic construction shields

against motor control fields) � 6-axis controller

3.5. Light Beam Unit The light beam switch allows automatic “tooling” of the probe. During the process, the actual position of the probe tip with respect to the robot arm is measured, as well as the probe length and the horizontal probe offset. The software then corrects all movements, such that the robot coordinates are valid for the probe tip. The repeatability of this process is better than 0.1 mm. If a position has been taught with an aligned prob.1 mm, even if the other probe has different dimensions. During probe rotations, the probe tip will keep its actual position. e, the same position will be reached with another aligned probe within 0

Report No.: AGC00377160401EH01 Page 11 of 114

3.6. Device Holder The DASY device holder is designed to cope with different positions given in the standard. It has two scales for the device rotation (with respect to the body axis) and the device inclination (with respect to the line between the ear reference points). The rotation center for both scales is the ear reference point (EPR). Thus the device needs no repositioning when changing the angles. The DASY device holder has been made out of low-loss POM material having the following dielectric parameters: relative permittivity ε=3 and loss tangent δ = 0.02. The amount of dielectric material has been reduced in the closest vicinity of the device, since measurements have suggested that the influence of the clamp on the test results could thus be lowered.

3.7. Measurement Server The measurement server is based on a PC/104 CPU board with CPU (DASY5: 400 MHz, Intel Celeron), chip-disk (DASY5: 128MB), RAM (DASY5: 128MB). The necessary circuits for communication with the DAE electronic box, as well as the 16 bit AD converter system for optical detection and digital I/O interface are contained on the DAYS I/O board, which is directly connected to the PC/104 bus of the CPU board. The measurement server performs all the real-time data evaluation for field measurements and surface detection, controls robot movements and handles safety operations.

Report No.: AGC00377160401EH01 Page 12 of 114

3.8. PHANTOM SAM Twin Phantom The SAM twin phantom is a fiberglass shell phantom with 2mm shell thickness (except the ear region where shell thickness increases to 6mm). It has three measurement areas: � Left head � Right head � Flat phantom

The bottom plate contains three pair of bolts for locking the device holder. The device holder positions are adjusted to the standard measurement positions in the three sections. A white cover is provided to tap the phantom during off-periods to prevent water evaporation and changes in the liquid parameters. On the phantom top, three reference markers are provided to identify the phantom position with respect to the robot.

ELI4 Phantom � Flat phantom a fiberglass shell flat phantom with 2mm+/- 0.2 mm shell thickness. It has only one measurement area for Flat phantom

Report No.: AGC00377160401EH01 Page 13 of 114

4. SAR MEASUREMENT PROCEDURE

4.1. Specific Absorption Rate (SAR)

SAR is related to the rate at which energy is absorbed per unit mass in object exposed to a radio field. The SAR distribution in a biological body is complicated and is usually carried out by experimental techniques or numerical modeling. The standard recommends limits for two tiers of groups, occupational/controlled and occupational/uncontrolled, based on a person’s awareness and ability to exercise control over his or her exposure. In general, occupational/controlled exposure limits are higher than the limits for general population/uncontrolled.

The SAR definition is the time derivative (rate) of the incremental energy (dW) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dv) of given mass density (ρ). The equation description is as below:

SAR is expressed in units of Watts per kilogram (W/Kg) SAR can be obtained using either of the following equations:

Where SAR is the specific absorption rate in watts per kilogram;

E is the r.m.s. value of the electric field strength in the tissue in volts per meter; ζ is the conductivity of the tissue in siemens per metre;

ρ is the density of the tissue in kilograms per cubic metre; ch is the heat capacity of the tissue in joules per kilogram and Kelvin;

dT

dt│t = 0 is the initial time derivative of temperature in the tissue in kelvins per second

Report No.: AGC00377160401EH01 Page 14 of 114

4.2. SAR Measurement Procedure

Step 1: Power Reference Measurement

The Power Reference Measurement and Power Drift Measurement are for monitoring the power drift of the device under test in the batch process. The minimum distance of probe sensors to surface is 2.7mm This distance cannot be smaller than the distance os sensor calibration points to probe tip as `defined in the probe properties,

Step 2: Area Scan

The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it computes the field maximal found in the scanned area, within a range of the global maximum. The range (in db) is specified in the standards for compliance testing. For example, a 2db range is required in IEEE Standard 1528-2013, EN 50360 and IEC62209 standards, whereby 3db is a requirement when compliance is assessed in accordance with the ARIB standard (Japan) If one Zoom Scan follows the Area Scan, then only the absolute maximum will be taken as reference. For cases where multiple maximum are detected, the number of Zoom Scan has to be increased accordingly.

measure the SAR distribution within the phantom (area scan procedure). The SAR distribution is scanned along the inside surface of one side of the phantom head, at least for an area larger than the projection of the handset and antenna. The spatial grid step shall be less than 20 mm. The resolution accuracy can also be tested using the reference functions of 7.2.4. If surface scanning is used, then the distance between the geometrical centre of the probe dipoles and the inner surface of the phantom shall be 8,0 mm or less (±1,0 mm). At all measurement points, the angle of the probe with respect to the line normal to the surface is recommended but not required to be less than 30°.

Step 3: Zoom Scan

Zoom Scan are used to assess the peak spatial SAR value within a cubic average volume containing 1g and 10g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces are centered on the maxima found in a preceding area scan job within the same procedure. When the measurement is done, the Zoom Scan evaluates the averaged SAR for 1g and 10g and displays these values next to the job’s label.

measure SAR with a grid step of 8 mm or less in a volume with a minimum size of 30 mm by 30 mm and 30 mm in depth (zoom scan procedure). The grid step in the vertical direction shall be 5 mm or less (see C.3.3). Separate grids shall be centred on each of the local SAR maxima found in step c). Step 4: Power Drift Measurement

The Power Drift Measurement measures the field at the same location as the most recent power reference measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field difference in dB from the reading conducted within the same settings. This allows a user to monitor the power drift of the device under test within a batch process. The measurement procedure is the same as Step 1.

Report No.: AGC00377160401EH01 Page 15 of 114

5. TISSUE SIMULATING LIQUID

For SAR measurement of the field distribution inside the phantom, the phantom must be filled with homogeneous tissue simulating liquid to a depth of at least 15cm. For head SAR testing the liquid height from the ear reference point (ERP) of the phantom to the liquid top surface is larger than 15cm For body SAR testing, the liquid height from the center of the flat phantom to the liquid top surface is larger than 15cm.The nominal dielectric values of the tissue simulating liquids in the phantom and the tolerance of 5% are listed in 5.2.

5.1. The composition of the tissue simulating liquid Ingredient (% Weight)

Frequency (MHz)

Water Nacl Sugar HEC Bactericide DGBE 1,2-

Propanediol Triton X-100

900 34.4 0.79 0.0 0.0 0.0 0.0 64.81 0.0

1800 55.36 0.35 0.0 0.0 0.0 13.84 0.0 30.45

2000 50 0.0 0.0 0.0 0.0 50 0.0 0.0

2450 71.88 0.16 0.0 0.0 0.0 7.99 0.0 19.97

5.2. Tissue Dielectric Parameters for Head and Body Phantoms

The head tissue dielectric parameters recommended by the EN/IEC 62209-1 have been incorporated in the following table. The body tissue dielectric parameters recommended by the EN/IEC 62209-2 have been incorporated in the following table.

Target Frequency (MHz)

head body

εr σ (S/m) εr σ (S/m)

300 45.3 0.87 45.3 0.87

450 43.5 0.87 43.5 0.87

835 41.5 0.90 41.5 0.90

900 41.5 0.97 41.5 0.97

1450 40.5 1.20 40.5 1.20

1800 – 2000 40.0 1.40 40.0 1.40

2450 39.2 1.80 39.2 1.80

3000 38.5 2.40 38.5 2.40

(εr = relative permittivity, ζ = conductivity and ρ = 1000 kg/m3)

Report No.: AGC00377160401EH01 Page 16 of 114

5.3. Tissue Calibration Result

The dielectric parameters of the liquids were verified prior to the SAR evaluation using DASY5 Dielectric Probe Kit and R&S Network Analyzer ZVL6.

Frequency (MHz)

Target Value Measurement Value Tissue Temp [oC]

Test Date εr δ[s/m] εr δ[s/m]

900 41.50

39.425-43.575 0.97

0.9225-1.0185 41.63 0.96 21.4 Apr. 25,2016

1800 40.00

38.00-42.00 1.40

1.33-1.47 40.35 1.43 21.9 Apr. 23,2016

2000 40.00

38.00-42.00 1.40

1.33-1.47 41.05 1.39 21.3 Apr. 21,2016

2450 39.2

37.24-41.16 1.80

1.71-1.89 39.99 1.81 21.9 Apr. 22,2016

Report No.: AGC00377160401EH01 Page 17 of 114

6. SAR SYSTEM CHECK PROCEDURE

6.1. SAR System Check Procedures SAR system check is required to confirm measurement accuracy, according to the tissue dielectric media, probe calibration points and other system operating parameters required for measuring the SAR of a test device. The system verification must be performed for each frequency band and within the valid range of each probe calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations used with each specific SAR system for system verification must be used for device testing. When multiple probe calibration points are required to cover substantially large transmission bands, independent system verifications are required for each probe calibration point. A system verification must be performed before each series of SAR measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric parameters, typically every three to four days when the liquid parameters are remeasured or sooner when marginal liquid parameters are used at the beginning of a series of measurements.

Each DASY system is equipped with one or more system check kits. These units, together with the predefined measurement procedures within the DASY software, enable the user to conduct the system check and system validation. System kit includes a dipole, and dipole device holder.

The system check verifies that the system operates within its specifications. It’s performed daily or before every SAR measurement. The system check uses normal SAR measurement in the flat section of the phantom with a matched dipole at a specified distance. The system check setup is shown as below.

Report No.: AGC00377160401EH01 Page 18 of 114

6.2. SAR System Check 6.2.1. Dipoles

The dipoles used is based on the EN/IEC62209-1/2 standard, the table below provides details for the mechanical and electrical Specifications for the dipoles.

The dipoles used is based on the EN/IEC62209-1/2 standard, the table below provides details for the mechanical and electrical Specifications for the dipoles.

Frequency L (mm) h (mm) d (mm)

900 MHz 149.0 83.3 3.6

1800MHz 72 41.7 3.6

2000 MHz 64.5 37.5 3.6

2450MHz 51.5 30.4 3.6

Report No.: AGC00377160401EH01 Page 19 of 114

6.2.2. System Check Result

System Performance Check at 900 MHz &1800MHz&2000MHz& 2450MHz

Validation Kit: SN 46/11DIP 0G900-185 & SN 46/11DIP 1G800-186 & SN 46/11DIP 2G000-188& D2450V2-SN:968

Frequency [MHz]

Target Value(W/Kg)

Reference Result (± 10%)

Normalized to 1W(W/Kg)

Tissue Temp.

[°C] Test time

1g 10g 1g 10g 1g 10g

900 10.70 6.72 9.63-11.77 6.048-7.392 10.381 6.752 21.4 Apr. 25,2016

1800 38.17 19.98 34.353-41.987 17.982-21.978 37.879 21.079 21.9 Apr. 23,2016

2000 42.10 20.52 37.89-46.31 18.468-22.572 39.939 20.921 21.3 Apr. 21,2016

2450 53.8 25.4 48.42-59.18 22.86-27.94 49.607 23.932 21.9 Apr. 22,2016

Report No.: AGC00377160401EH01 Page 20 of 114

7. EUT TEST POSITION

This EUT was tested in Right Cheek, Right Tilted, Left Cheek, Left Tilted, Body back and Body front.

7.1. Define Two Imaginary Lines on the Handset

(1)The vertical centerline passes through two points on the front side of the handset the midpoint of the width wt of the handset at the level of the acoustic output, and the midpoint of the width wb of the handset.

(2)The horizontal line is perpendicular to the vertical centerline and passes through the center of the acoustic output. The horizontal line is also tangential to the face of the handset at point A.

(3)The two lines intersect at point A. Note that for many handsets, point A coincides with the center of the acoustic output; however, the acoustic output may be located elsewhere on the horizontal line. Also note that the vertical centerline is not necessarily to the front face of the handset, especially for clamshell handsets, handsets with flip covers, and other irregularly shaped handsets.

Report No.: AGC00377160401EH01 Page 21 of 114

7.2. Cheek Position

(1) To position the device with the vertical center line of the body of the device and the horizontal line crossing the center picec in a plane parallel to the sagittal plane of the phantom. While maintaining the device in this plane, align the vertical center line with the reference plane containing the ear and mouth reference point (M: Mouth, RE: Right Ear, and LE: Left Ear) and align the center of the ear piece with the line RE-LE.

(2) To move the device towards the phantom with the ear piece aligned with the the line LE-RE until the phone touched the ear. While maintaining the device in the reference plane and maintaining the phone contact with ear, move the bottom of the phone until any point on the front side is in contact with the cheek of the phantom or until contact with the ear is lost

7.3. Tilt Position

(1) To position the device in the “cheek” position described above.

(2) While maintaining the device in the reference plane described above and pivoting against the ear, moves it outward away from the mouth by an angle of 15 degrees or until with the ear is lost.

Report No.: AGC00377160401EH01 Page 22 of 114

7.4. Body Worn Position

(1) To position the EUT parallel to the phantom surface.

(2) To adjust the EUT parallel to the flat phantom.

(3) To adjust the distance between the EUT surface and the flat phantom to 5mm.

Report No.: AGC00377160401EH01 Page 23 of 114

8. SAR EXPOSURE LIMITS

SAR assessments have been made in line with the requirements of 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public electromagnetic fields (0 Hz-300GHz).

Limits for General Population/Uncontrolled Exposure (W/kg)

Type Exposure Uncontrolled Environment Limit (W/kg)

Spatial Peak SAR (10 g cube tissue for brain or body) 2.00

Spatial Average SAR (Whole body) 0.08

Spatial Peak SAR (Limbs) 4.00

Report No.: AGC00377160401EH01 Page 24 of 114

9. TEST EQUIPMENT LIST Equipment description

Manufacturer/ Model

Identification No. Current

calibration date Next calibration

date

Stäubli Robot Stäubli-TX60 F13/5Q2UD1/A/01 N/A N/A

Robot Controller Stäubli-CS8 139522 N/A N/A

TISSUE Probe SATIMO SN 45/11 OCPG45 12/02/2015 12/01/2016

E-Field Probe Speag- ES3DV3 SN:3337 10/01/2015 09/30/2016

SAM Twin Phantom Speag-SAM 1790 N/A N/A

Device Holder Speag-SD 000 H01

KA SD 000 H01 KA N/A N/A

DAE4 Speag-SD 000 D04

BM 1398 02/02/2016 02/01/2017

SAR Software Speag-DASY5 DASY52.8 N/A N/A

Liquid SATIMO - N/A N/A

Radio Communication

Tester R&S-CMU200 069Y7-158-13-712 03/04/2016 03/03/2017

Dipole SATIMO SID900 SN46/11 DIP 0G900-185

11/14/2013 11/13/2016

Dipole SATIMO SID1800 SN46/11 DIP 1G800-186

11/14/2013 11/13/2016

Dipole SATIMO SID2000 SN46/11 DIP 2G000-188

11/14/2013 11/13/2016

Dipole D2450V2 SN968 06/12/2015 06/11/2018

Signal Generator Agilent-E4438C MY44260051 03/04/2016 03/03/2017

Spectrum Analyzer E4440

Agilent US41421290 07/23/2015 07/22/2016

Network Analyzer Rhode & Schwarz

ZVL6 SN100132 03/04/2016 03/03/2017

Attenuator Warison

/WATT-6SR1211 N/A N/A N/A

Attenuator Mini-circuits /

VAT-10+ N/A N/A N/A

Amplifier EM30180 SN060552 03/04/2016 03/03/2017

Directional Couple

Werlatone/ C5571-10

SN99463 07/29/2015 07/28/2016

Directional Couple

Werlatone/ C6026-10

SN99482 07/29/2015 07/28/2016

Power Sensor NRP-Z21 1137.6000.02 10/20/2015 10/19/2016

Power Sensor NRP-Z23 US38261498 03/04/2016 03/03/2017

Power Viewer R&S V2.3.1.0 N/A N/A

Note: Per EN/IEC62209-1/2 Dipole SAR Validation, AGC Lab has adopted 3 years calibration intervals. On annual basis, every measurement dipole has been evaluated and is in compliance with the following criteria: 1. There is no physical damage on the dipole; 2. System validation with specific dipole is within 10% of calibrated value; 3. Return-loss is within 20% of calibrated measurement; 4. Impedance is within 5Ω of calibrated measurement.

Report No.: AGC00377160401EH01 Page 25 of 114

10. MEASUREMENT UNCERTAINTY The component of uncertainly may generally be categorized according to the methods used to evaluate them. The evaluation of uncertainly by the statistical analysis of a series of observations is termed a Type An evaluation of uncertainty. The evaluation of uncertainty by means other than the statistical analysis of a series of observation is termed a Type B evaluation of uncertainty. Each component of uncertainty, however evaluated, is represented by an estimated standard deviation, termed standard uncertainty, which is determined by the positive square root of the estimated variance. A Type A evaluation of standard uncertainty may be based on any valid statistical method for treating data. This includes calculating the standard deviation of the mean of a series of independent observations; using the method of least squares to fit a curve to the data in order to estimate the parameter of the curve and their standard deviations; or carrying out an analysis of variance in order to identify and quantify random effects in certain kinds of measurement.

A type B evaluation of standard uncertainty is typically based on scientific judgment using all of the relevant information available. These may include previous measurement data, experience, and knowledge of the behavior and properties of relevant materials and instruments, manufacture’s specification, data provided in calibration reports and uncertainties assigned to reference data taken from handbooks. Broadly speaking, the uncertainty is either obtained from an outdoor source or obtained from an assumed distribution, such as the normal distribution, rectangular or triangular distributions indicated in Table as follow.

Uncertainty Distributions

Normal Rectangular Triangular U-Shape

Multi-plying Factor(a)

1/k(b) 1/ 3 1/ 6 1/ 2

(a) Standard uncertainty is determined as the product of the multiplying factor and the estimated range of variations in the measured quantity

(b) κ is the coverage factor

Table 13.1 Standard Uncertainty for Assumed Distribution (above table)

The combined standard uncertainty of the measurement result represents the estimated standard deviation of the result. It is obtained by combining the individual standard uncertainties of both Type A and Type B evaluation using the usual “root-sum-squares” (RSS) methods of combining standard deviations by taking the positive square root of the estimated variances.

Expanded uncertainty is a measure of uncertainty that defines an interval about the measurement result within which the measured value is confidently believed to lie. It is obtained by multiplying the combined standard uncertainty by a coverage factor. Typically, the coverage factor ranges from 2 to 3. Using a coverage factor allows the true value of a measured quantity to be specified with a defined probability within the specified uncertainty range. For purpose of this document, a coverage factor two is used, which corresponds to confidence interval of about 95 %. The DASY uncertainty Budget is shown in the following tables.

Report No.: AGC00377160401EH01 Page 26 of 114

DAYS5 Measurement Uncertainty Measurement uncertainty for 150 MHz to 3GHz averaged over 1 gram / 10 gram.

Error Description Uncertainty value(±10%

)

Probability Distribution

Divisor (Ci) 1g

(Ci) 10g

Standard Uncertainty

(1g)

Standard Uncertainty

(10g)

Measurement System

Probe Calibration 6 Normal 1 1 1 6.00 6.00

Axial Isotropy 0.25 Rectangular 3 1 1 0.14 0.14

Hemispherical Isotropy 1.3 Rectangular 3 1 1 0.75 0.75

Linearity 0.3 Rectangular 3 1 1 0.17 0.17

Probe Modulation Response

1.65 Rectangular 3 1 1 0.95 0.95

System Detection Limits 0.9 Rectangular 3 1 1 0.52 0.52

Boundary Effects 0.9 Rectangular 3 1 1 0.52 0.52

Readout Electronics 0.2 Normal 1 1 1 0.20 0.20

Response Time 0 Rectangular 3 1 1 0.00 0.00

Integration Time 0 Rectangular 3 1 1 0.00 0.00

RF Ambient Noise 0.9 Rectangular 3 1 1 0.52 0.52

RF Ambient Reflection 0.9 Rectangular 3 1 1 0.52 0.52

Probe Positioner 0.7 Rectangular 3 1 1 0.40 0.40

Probe Positioning 6.5 Rectangular 3 1 1 3.75 3.75

Post-processing 3.8 Rectangular 3 1 1 2.19 2.19

Test Sample Related

Device Positioning 3.6 Normal 1 1 1 3.6 3.6

Device Holder 2.9 Normal 1 1 1 2.9 2.9

Measurement SAR Drift 5.0 Rectangular 3 1 1 2.89 2.89

Power Scaling 0.0 Rectangular 3 1 1 0 0

Phantom and Setup

Phantom Uncertainty (Shape and thickness tolerances)

0.05 Normal 3 1 1 0.03 0.03

Uncertainty in SAR correction for deviations in permittivity and conductivity

1.9 Rectangular 1 1 0.84 1.90 1.60

Liquid conductivity measurement

5 Normal 1 0.78 0.71 3.90 3.55

Liquid permittivity measurement

5 Rectangular 1 0.23 0.26 1.15 1.30

Liquid conductivity – temperature uncertainty

5 Rectangular 3 0.78 0.71 2.25 2.05

Liquid permittivity – temperature uncertainty

5 Rectangular 3 0.23 0.26 0.66 0.75

Combined Standard Uncertainty 10.17 9.89

Coverage Factor for 95% K=2

Expanded Uncertainty ±20.34% ±19.779%

Report No.: AGC00377160401EH01 Page 27 of 114

DAYS5 System Check Uncertainty for 150 MHz to 3GHz averaged range

Error Description Uncer. value

(±10%)

Prob. Dist.

Div. (Ci) 1g

(Ci) 10g

Std. Unc. (1g)

Std. Unc. (10g)

(vi) Veff

Measurement System

Probe Calibration 6 Normal 1 1 1 6.00 6.00 ∞

Axial Isotropy 0.25 Rectangular 3 1 1 0.14 0.14 ∞

Hemispherical Isotropy 1.3 Rectangular 3 1 1 0.75 0.75 ∞

Boundary Effects 0.3 Rectangular 3 1 1 0.17 0.17 ∞

Linearity 1.65 Rectangular 3 1 1 0.95 0.95 ∞

System Detection Limits 0.9 Rectangular 3 1 1 0.52 0.52 ∞

Modulation Response 0.9 Rectangular 3 1 1 0.52 0.52 ∞

Readout Electronics 0.2 Normal 1 1 1 0.20 0.20 ∞

Response Time 0 Rectangular 3 1 1 0.00 0.00 ∞

Integration Time 0 Rectangular 3 1 1 0.00 0.00 ∞

RF Ambient Noise 0.9 Rectangular 3 1 1 0.52 0.52 ∞

RF Ambient Reflection 0.9 Rectangular 3 1 1 0.52 0.52 ∞

Probe Positioner 0.7 Rectangular 3 1 1 0.40 0.40 ∞

Probe Positioning 6.5 Rectangular 3 1 1 3.75 3.75 ∞

Max. SAR Eval. 3.8 Rectangular 3 1 1 2.19 2.19 ∞

Dipole Related

Deviation of exp. dipole 5.3 Rectangular 3 1 1 3.06 3.06 ∞

Dipole Axis to Liquid Dist. 2.0 Rectangular 3 1 1 1.15 1.15 ∞

Input power & SAR drift 3.3 Rectangular 3 1 1 1.91 1.91 ∞

Phantom and Setup

Phantom Uncertainty (Shape and thickness tolerances)

0.05 Normal 3 1 1 0.03 0.03 ∞

Uncertainty in SAR correction for deviations in permittivity and conductivity

1.9 Rectangular 1 1 0.84 1.90 1.60 ∞

Liquid conductivity measurement

5 Normal 1 0.78 0.71 3.90 3.55 ∞

Liquid permittivity measurement

5 Rectangular 1 0.23 0.26 1.15 1.30 ∞

Liquid conductivity – temperature uncertainty

5 Rectangular 3 0.78 0.71 2.25 2.05 ∞

Liquid permittivity – temperature uncertainty

5 Rectangular 3 0.23 0.26 0.66 0.75 ∞

Combined Std. Uncertainty

9.38 9.080

Expanded STD Uncertainty

±18.77% ±18.16%

Report No.: AGC00377160401EH01 Page 28 of 114

11. CONDUCTED POWER MEASUREMENT GSM BAND

Mode Frequency(MHz) Avg. Burst

Power(dBm) Duty cycle

Factor(dBm) Frame

Power(dBm)

Maximum Power <1>

GSM 900

880.2 31.40 -9 22.40

897.4 31.42 -9 22.42

914.8 31.39 -9 22.39

GPRS 900

(1 Slot)

880.2 31.26 -9 22.26

897.4 31.33 -9 22.33

914.8 31.25 -9 22.25

GPRS 900

(2 Slot)

880.2 28.54 -6 22.54

897.4 28.57 -6 22.57

914.8 28.53 -6 22.53

GPRS 900

(3 Slot)

880.2 26.62 -4.26 22.36

897.4 26.66 -4.26 22.40

914.8 26.63 -4.26 22.37

GPRS 900

(4 Slot)

880.2 25.79 -3 22.79

897.4 25.83 -3 22.83

914.8 25.81 -3 22.81

EGPRS 900

(1 Slot)

880.2 26.44 -9 17.44

897.4 26.45 -9 17.45

914.8 26.42 -9 17.42

EGPRS 900

(2 Slot)

880.2 23.52 -6 17.52

897.4 23.56 -6 17.56

914.8 23.53 -6 17.53

EGPRS 900

(3 Slot)

880.2 22.67 -4.26 18.41

897.4 22.69 -4.26 18.43

914.8 22.62 -4.26 18.36

EGPRS 900

(4 Slot)

880.2 21.54 -3 18.54

897.4 21.58 -3 18.58

914.8 21.53 -3 18.53

Report No.: AGC00377160401EH01 Page 29 of 114

Mode Frequency(MHz) Avg. Burst

Power(dBm) Duty cycle

Factor(dBm) Frame

Power(dBm)

Maximum Power <2>

GSM 900

880.2 31.39 -9 22.39

897.4 31.41 -9 22.41

914.8 31.35 -9 22.35

GPRS 900

(1 Slot)

880.2 31.21 -9 22.21

897.4 31.29 -9 22.29

914.8 31.25 -9 22.25

GPRS 900

(2 Slot)

880.2 28.52 -6 22.52

897.4 28.55 -6 22.55

914.8 28.48 -6 22.48

GPRS 900

(3 Slot)

880.2 26.63 -4.26 22.37

897.4 26.65 -4.26 22.39

914.8 26.58 -4.26 22.32

GPRS 900

(4 Slot)

880.2 25.78 -3 22.78

897.4 25.81 -3 22.81

914.8 25.76 -3 22.76

Report No.: AGC00377160401EH01 Page 30 of 114

Mode Frequency(MHz) Avg. Burst

Power(dBm) Duty cycle

Factor(dBm) Frame

Power(dBm)

Maximum Power <1>

DCS1800

1710.2 28.35 -9 19.35

1747.4 28.38 -9 19.38

1784.8 28.32 -9 19.32

GPRS1800

(1 Slot)

1710.2 28.26 -9 19.26

1747.4 28.26 -9 19.26

1784.8 28.30 -9 19.30

GPRS1800

(2 Slot)

1710.2 25.45 -6 19.45

1747.4 25.52 -6 19.52

1784.8 25.48 -6 19.48

GPRS1800

(3 Slot)

1710.2 23.75 -4.26 19.49

1747.4 23.76 -4.26 19.50

1784.8 23.73 -4.26 19.47

GPRS1800

(4 Slot)

1710.2 22.84 -3 19.84

1747.4 22.87 -3 19.87

1784.8 22.83 -3 19.83

EGPRS1800

(1 Slot)

1710.2 25.42 -9 16.42

1747.4 25.43 -9 16.43

1784.8 25.38 -9 16.38

EGPRS1800

(2 Slot)

1710.2 23.55 -6 17.55

1747.4 23.59 -6 17.59

1784.8 23.54 -6 17.54

EGPRS1800

(3 Slot)

1710.2 23.64 -4.26 19.38

1747.4 23.63 -4.26 19.37

1784.8 23.58 -4.26 19.32

EGPRS1800

(4 Slot)

1710.2 20.76 -3 17.76

1747.4 20.83 -3 17.83

1784.8 20.79 -3 17.79

Report No.: AGC00377160401EH01 Page 31 of 114

Mode Frequency(MHz) Avg. Burst

Power(dBm) Duty cycle

Factor(dBm) Frame

Power(dBm)

Maximum Power <2>

DCS1800

1710.2 28.33 -9 19.33

1747.4 28.35 -9 19.35

1784.8 28.33 -9 19.33

GPRS1800

(1 Slot)

1710.2 28.21 -9 19.21

1747.4 28.25 -9 19.25

1784.8 28.20 -9 19.20

GPRS1800

(2 Slot)

1710.2 25.44 -6 19.44

1747.4 25.50 -6 19.50

1784.8 25.48 -6 19.48

GPRS1800

(3 Slot)

1710.2 23.72 -4.26 19.46

1747.4 23.75 -4.26 19.49

1784.8 23.68 -4.26 19.42

GPRS1800

(4 Slot)

1710.2 22.80 -3 19.80

1747.4 22.86 -3 19.86

1784.8 22.83 -3 19.83

Note 1: The Frame Power (Source-based time-averaged Power) is scaled the maximum burst average power based on time slots. The calculated methods are show as following: Frame Power = Max burst power (1 Up Slot) – 9 dB Frame Power = Max burst power (2 Up Slot) – 6 dB Frame Power = Max burst power (3 Up Slot) – 4.26 dB Frame Power = Max burst power (4 Up Slot) – 3 dB Note 2: SAR is not required for GPRS (1 Slot) Mode because its output power is less than of Voice Mode

Report No.: AGC00377160401EH01 Page 32 of 114

UMTS BAND I

Mode Frequency(MHz) Avg. Burst Power (dBm)

WCDMA 2100 RMC(12.2kbps)

1922.4 23.89

1950 23.93

1977.6 23.91

HSDPA

Subtest 1

1922.4 22.84

1950 22.89

1977.6 22.86

HSDPA

Subtest 2

1922.4 22.75

1950 22.82

1977.6 22.76

HSDPA

Subtest 3

1922.4 22.54

1950 22.62

1977.6 22.58

HSDPA

Subtest 4

1922.4 22.63

1950 22.54

1977.6 22.47

HSUPA

Subtest 1

1922.4 21.58

1950 21.62

1977.6 21.54

HSUPA

Subtest 2

1922.4 21.47

1950 21.52

1977.6 21.46

HSUPA

Subtest 3

1922.4 21.53

1950 21.21

1977.6 21.26

HSUPA

Subtest 4

1922.4 21.32

1950 21.34

1977.6 21.19

HSUPA

Subtest 5

1922.4 21.24

1950 21.26

1977.6 21.30

Report No.: AGC00377160401EH01 Page 33 of 114

UMTS BAND VIII

Mode Frequency (MHz) Avg. Burst Power (dBm)

WCDMA 900 RMC(12.2kbps)

882.4 23.35

897.6 23.37

912.6 23.32

HSDPA

Subtest 1

882.4 22.44

897.6 22.46

912.6 22.42

HSDPA

Subtest 2

882.4 22.35

897.6 22.35

912.6 22.32

HSDPA

Subtest 3

882.4 22.24

897.6 22.30

912.6 22.28

HSDPA

Subtest 4

882.4 22.21

897.6 22.26

912.6 22.30

HSUPA

Subtest 1

882.4 21.55

897.6 21.57

912.6 21.54

HSUPA

Subtest 2

882.4 21.43

897.6 21.48

912.6 21.42

HSUPA

Subtest 3

882.4 21.36

897.6 21.38

912.6 21.24

HSUPA

Subtest 4

882.4 21.31

897.6 21.26

912.6 21.30

HSUPA

Subtest 5

882.4 21.15

897.6 21.24

912.6 21.22

Report No.: AGC00377160401EH01 Page 34 of 114

According to 3GPP 25.101 sub-clause 6.2.2, the maximum output power is allowed to be reduced by following the table.

Table 6.1Aa: UE maximum output power with HS-DPCCH and E-DCH

UE Transmit Channel Configuration CM(db) MPR(db)

For all combinations of ,DPDCH,DPCCH HS-DPDCH,E-DPDCH and E-DPCCH

0≤ CM≤3.5 MAX(CM-1,0)

Note: CM=1 for c/ d=12/15, hs/ c=24/15.For all other combinations of DPDCH, DPCCH, HS-DPCCH,

E-DPDCH and E-DPCCH the MPR is based on the relative CM difference.

The device supports MPR to solve linearity issues (ACLR or SEM) due to the higher peak-to average ratios (PAR) of the HSUPA signal. This prevents saturating the full range of the TX DAC inside of device and provides a reduced power output to the RF transceiver chip according to the Cubic Metric (a function of the combinations of DPDCH, DPCCH, HS-DPCCH, E-DPDCH and E-DPCCH).

When E-DPDCH channels are present the beta gains on those channels are reduced firsts to try to get the power under the allowed limit. If the beta gains are lowered as far as possible, then a hard limiting is applied at the maximum allowed level.

The SW currently recalculates the cubic metric every time the beta gains on the E-DPDCH are reduced. The cubic metric will likely get lower each time this is done .However, there is no reported reduction of maximum output power in the HSUPA mode since the device also provides a compensation for the power back-off by increasing the gain of TX_AGC in the transceiver (PA) device.

The end effect is that the DUT output power is identical to the case where there is no MPR in the device.

Report No.: AGC00377160401EH01 Page 35 of 114

WIFI

Mode Data Rate (Mbps) Channel Frequency(MHz) EIRP (dBm)

802.11b 1

1 2412 10.71

7 2442 9.95

13 2472 9.79

802.11g 6

1 2412 6.59

7 2442 7.78

13 2472 7.09

802.11n(20) 6.5

1 2412 6.97

7 2442 7.92

13 2472 7.14

802.11n(40) 13.5

3 2422 4.53

7 2442 7.31

11 2462 6.74

Report No.: AGC00377160401EH01 Page 36 of 114

12. TEST RESULTS

12.1. SAR Test Results Summary 12.1.1. Test position and configuration

Head SAR was performed with the device configured in the positions according to IEC/EN62209-1, and Body SAR was performed with the device 5mm from the phantom according to IEC/EN62209-2.

12.1.2. Operation Mode 1 For GSM850, the power control is set to Maximum Power Class. For GSM900, the power control is set to

Maximum Power Class. For GPRS 900(GMSK, CS1), the power control level is set to Maximum Power Class. For E-GPRS 900(GMSK: MCS1, 8PSK:MCS5), the power control is set to Maximum Power Class. For DCS 1800, the power control is set to Maximum Power Class. For GPRS 1800(GMSK, CS1), the power control level is set to Maximum Power Class. For E-GPRS 1800 (GMSK: MCS1, 8PSK:MCS5), the power control level is set to Maximum Power Class.

This is a multi-slot class 12 device capable of 4 uplink timeslots. During the head SAR test, the device was transmitting with maximum 1 uplink timeslot; during the body SAR test, it was transmitting with maximum 4 uplink timeslots. Additionally, this device doesn’t support dual transfer mode (DTM)

Testing with the headset was performed at the position and channels that resulted in the highest body SAR. This testing was performed with GPRS transmitting with 2/3/4 uplink timeslots. In the Body SAR test result table, body-worn means display of device down, body-front means display of device up.

2 For WCDMA, head and body SAR is tested under RMC 12.2k mode with power control set all up bits SAR for

AMR is not required since its power is less than RMC. For HSDPA/HSUPA, SAR is test with its maximum power mode.

3 For WLAN SAR testing, the EUT has installed WLAN engineering testing software which can provide continuous transmitting RF signal.

4. Sensors have no any influence on RF power level or SAR result. 5. The portion of the device which area scan did not scan has been off the phantom.

Report No.: AGC00377160401EH01 Page 37 of 114

12.1.3. Antenna Location: ( back view )

EUT Top Edge

EUT Right Edge EUT Left Edge

EUT Bottom Edge

GSM&WCDMA Antenna

BT&WIFI Antenna

Report No.: AGC00377160401EH01 Page 38 of 114

12.1.4. SAR Test Results Summary SAR MEASUREMENT

Depth of Liquid (cm):>15 Relative Humidity (%): 65

Product: Smart Phone

Test Mode: GSM900 with GMSK modulation

Position Mode Ch. Fr.

(MHz)

Power Drift

(<±0.2)

SAR (10g)

(W/kg)

Max. Turn-up Power (dBm)

Meas. output Power (dBm)

Scaled SAR

(W/Kg)

Limit (W/Kg)

SIM 1 Card

Left Cheek voice 975 880.2 -0.03 0.374 32.00 31.40 0.429 2.0

Left Cheek voice 37 897.4 0.06 0.355 32.00 31.42 0.406 2.0

Left Cheek voice 124 914.8 0.00 0.204 32.00 31.39 0.235 2.0

Left Tilt voice 37 897.4 -0.04 0.209 32.00 31.42 0.239 2.0

Right Cheek voice 37 897.4 -0.05 0.300 32.00 31.42 0.343 2.0

Right Tilt voice 37 897.4 -0.17 0.196 32.00 31.42 0.224 2.0

Body back voice 37 897.4 0.06 0.421 32.00 31.42 0.481 2.0

Body back GPRS-2 slots 37 897.4 -0.00 0.575 29.00 28.57 0.635 2.0

Body back GPRS-3 slots 37 897.4 0.00 0.623 27.00 26.66 0.674 2.0

Body back GPRS-4 slots 37 897.4 -0.02 0.838 26.00 25.83 0.871 2.0

Body Front GPRS-4 slots 37 897.4 0.01 0.709 26.00 25.83 0.737 2.0

Body back GPRS-4 slots with Ear.

37 897.4 .05 0.865 26.00 25.83 0.900 2.0

SIM 2 Card

Left Cheek voice 975 880.2 0.07 0.333 32.00 31.39 0.383 2.0

Body back GPRS-4 slots with Ear.

37 897.4 -0.01 0.756 26.00 25.81 0.790 2.0

Note:

·When the 10-g SAR is ≤ 1.0W/kg, testing for low and high channel is optional.

·The test separation of all above table(body part) is 5mm.

Report No.: AGC00377160401EH01 Page 39 of 114

SAR MEASUREMENT

Depth of Liquid (cm):>15 Relative Humidity (%): 58.8

Product: Smart Phone

Test Mode: DCS1800 with GMSK modulation

Position Mode Ch. Fr.

(MHz)

Power Drift

(<±0.2)

SAR (10g)

(W/kg)

Max. Turn-up Power (dBm)

Meas. output Power (dBm)

Scaled SAR

(W/Kg)

Limit (W/Kg)

SIM 1 Card

Left Cheek voice 512 1710.2 0.18 0.127 29.00 28.35 0.148 2.0

Left Cheek voice 698 1747.4 0.07 0.127 29.00 28.38 0.146 2.0

Left Cheek voice 885 1784.8 -0.01 0.164 29.00 28.32 0.192 2.0

Left Tilt voice 698 1747.4 -0.08 0.057 29.00 28.38 0.066 2.0

Right Cheek voice 698 1747.4 0.13 0.118 29.00 28.38 0.136 2.0

Right Tilt voice 698 1747.4 0.10 0.058 29.00 28.38 0.067 2.0

Body back voice 698 1747.4 0.05 0.508 29.00 28.38 0.586 2.0

Body back GPRS-2 slots 698 1747.4 0.01 0.442 26.00 25.52 0.494 2.0

Body back GPRS-3 slots 698 1747.4 -0.01 0.803 24.00 23.76 0.849 2.0

Body back GPRS-4 slots 698 1747.4 -0.01 0.899 23.00 22.87 0.926 2.0

Body Front GPRS-4 slots 698 1747.4 -0.01 0.895 23.00 22.87 0.922 2.0

Body back GPRS-4 slots with Ear.

698 1747.4 0.05 0.808 23.00 22.87 0.833 2.0

SIM 2 Card

Left Cheek voice 885 1784.8 -0.03 0.131 29.00 28.33 0.153 2.0

Body back GPRS-4 slots 698 1747.4 -0.00 0.720 23.00 22.86 0.744 2.0

Note:

·When the 10-g SAR is ≤ 1.0W/kg, testing for low and high channel is optional.

·The test separation of all above table(body part) is 5mm.

Report No.: AGC00377160401EH01 Page 40 of 114

SAR MEASUREMENT

Depth of Liquid (cm):>15 Relative Humidity (%): 51.7

Product: Smart Phone

Test Mode: WCDMA Band I with QPSK modulation

Position Mode Ch. Fr.

(MHz)

Power Drift

(<±0.2)

SAR (10g)

(W/kg)

Max. Turn-up Power (dBm)

Meas. output Power (dBm)

Scaled SAR

(W/Kg)

Limit W/kg

SIM 1 Card

Left Cheek RMC12.2kbps 9612 1922.4 0.01 0.164 24.00 23.89 0.168 2.0

Left Cheek RMC12.2kbps 9750 1950 -0.17 0.174 24.00 23.93 0.177 2.0

Left Cheek RMC12.2kbps 9888 1977.6 0.05 0.134 24.00 23.91 0.137 2.0

Left Tilt RMC12.2kbps 9750 1950 0.17 0.050 24.00 23.93 0.051 2.0

Right Cheek RMC12.2kbps 9750 1950 0.02 0.116 24.00 23.93 0.118 2.0

Right Tilt RMC12.2kbps 9750 1950 -0.05 0.057 24.00 23.93 0.058 2.0

Body back RMC12.2kbps 9750 1950 0.04 0.327 24.00 23.93 0.332 2.0

Body front RMC12.2kbps 9612 1922.4 0.18 1.050 24.00 23.89 1.077 2.0

Body front RMC12.2kbps 9750 1950 0.00 1.270 24.00 23.93 1.291 2.0

Body front RMC12.2kbps 9888 1977.6 0.16 1.010 24.00 23.91 1.031 2.0

Body back HSPA 9750 1950 0.19 0.805 23.00 22.89 0.826 2.0

Body front RMC12.2kbps with Ear. 9612 1922.4 -0.03 1.180 24.00 23.89 1.210 2.0

Body front RMC12.2kbps with Ear. 9750 1950 -0.08 1.220 24.00 23.93 1.240 2.0

Body front RMC12.2kbps with Ear. 9888 1977.6 0.01 1.160 24.00 23.91 1.184 2.0

Note:

·When the 10-g SAR is ≤ 1.0W/kg, testing for low and high channel is optional.

·The test separation of all above table(body part) is 5mm.

Report No.: AGC00377160401EH01 Page 41 of 114

SAR MEASUREMENT

Depth of Liquid (cm):>15 Relative Humidity (%): 65

Product: Smart Phone

Test Mode: WCDMA Band VIII with QPSK modulation

Position Mode Ch. Fr.

(MHz)

Power Drift

(<±0.2)

SAR (10g)

(W/kg)

Max. Turn-up Power (dBm)

Meas. output Power (dBm)

Scaled SAR

(W/Kg)

Limit W/kg

SIM 1 Card

Left Cheek RMC12.2kbps 2712 882.4 -0.05 0.204 24.00 23.35 0.237 2.0

Left Cheek RMC12.2kbps 2788 897.6 -0.01 0.237 24.00 23.37 0.274 2.0

Left Cheek RMC12.2kbps 2863 912.6 0.10 0.159 24.00 23.32 0.186 2.0

Left Tilt RMC12.2kbps 2788 897.6 -0.08 0.131 24.00 23.37 0.151 2.0

Right Cheek RMC12.2kbps 2788 897.6 0.08 0.225 24.00 23.37 0.260 2.0

Right Tilt RMC12.2kbps 2788 897.6 0.02 0.097 24.00 23.37 0.112 2.0

Body back RMC12.2kbps 2788 897.6 0.04 0.327 24.00 23.37 0.378 2.0

Body front RMC12.2kbps 2788 897.6 0.05 0.287 24.00 23.37 0.332 2.0

Body back HSPA 2788 897.6 0.01 0.303 23.00 22.46 0.343 2.0

Body back RMC12.2kbps with Ear.

2788 897.6 0.02 0.300 24.00 23.37 0.347 2.0

Note: ·When the 10-g SAR is ≤ 1.0W/kg, testing for low and high channel is optional.

·The test separation of all above table(body part) is 5mm.

Report No.: AGC00377160401EH01 Page 42 of 114

SAR MEASUREMENT

Depth of Liquid (cm):>15 Relative Humidity (%): 58.0

Product: Smart Phone

Test Mode: 802.11b

Position Mode Ch. Fr.

(MHz)

Power Drift

(<±0.2)

SAR (10g)

(W/kg)

Max. Turn-up Power (dBm)

Meas. output Power (dBm)

Scaled SAR

(W/Kg)

Limit W/kg

Left Cheek DTS 7 2442 0.05 0.077 11 9.95 0.098 2.0

Left Tilt DTS 7 2442 0.09 0.077 11 9.95 0.098 2.0

Right Cheek DTS 1 2412 0.01 0.207 11 10.71 0.221 2.0

Right Cheek DTS 7 2442 -0.09 0.234 11 9.95 0.298 2.0

Right Cheek DTS 13 2472 0.09 0.164 11 9.79 0.217 2.0

Right Tilt DTS 7 2442 -0.01 0.144 11 9.95 0.183 2.0

Body back DTS 7 2442 0.04 0.157 11 9.95 0.200 2.0

Body front DTS 7 2442 0.10 0.131 11 9.95 0.167 2.0

Body back + Ear. DTS 7 2442 -0.02 0.131 11 9.95 0.167 2.0

Note:

·When the 10-g SAR is ≤ 1.0W/kg, testing for low and high channel is optional.

·The test separation of all above table(body part) is 5mm.

Report No.: AGC00377160401EH01 Page 43 of 114

Simultaneous Multi-band Transmission Evaluation: According to EN62209-2:2010 section 6.3.2, when the EUT has more than one transmission mode, there need to take Simultaneous Multi-band Transmission into consideration; (1) The EUT has WWAN antenna, BT/ WLAN antenna; (2) BT and WIFI share one antenna, and cannot transmit simultaneously; (3) GSM and GPRS/WCDMA can’t work at the same time; (4) For simultaneous transmission at head and body exposure position, 2 transmitters simultaneous

transmission was the worst state; (5) For each transmission mode, there must test separately, and then summation of peak spatial-averaged SAR

values; (6) For secondary transmitter (i.e. lower power transmitters), we use the following measurement to evaluate if

their power levels fall below a threshold level(Annex k):

Pavailable=Pth,m×(SARlim -SAR1)/ SARlim

Where Pth,m is the threshold exclusion power level;

Pavailable is the threshold value there need to be tested; SARlim is the SAR limit; SAR1 is the maximum SAR value of first transmitter mode result; Alternatively, Pth,m can be replaced by Pmax,m, which is an easier approach but leads to more restrictive power threshold;

Pavailable=Pth,m×(SARlim -SAR1)/ SARlim=20mW×(2W/Kg -1.291W/Kg)/ 2W/Kg

=7.09mW>1.13mW(0.53dBm) for BT

=7.09mW<11.78mW(10.71dBm) for WIFI

There is no need to test BT and no need to evaluate simultaneous transmission. There is need to test WIFI and need to evaluate simultaneous transmission.

Report No.: AGC00377160401EH01 Page 44 of 114

Simultaneous Multi-band Transmission SAR:

NO Simultaneous state Portable Handset

Head Body-worn

1 GSM(voice)+WLAN 2.4GHz (data) Yes Yes

2 GSM(Data)+WLAN 2.4GHz (data) Yes Yes

3 WCDMA(RMC12.2kbps)+WLAN 2.4GHz (data) Yes Yes

Frequence RF

Exposure Conditions

Test Position

Simultaneous Transmission Scenario

Σ10-g SAR (W/Kg)

Limit (W/Kg)

WWAN WLAN

GSM 900

Head (voice)

Left Touch 0.429 0.098 0.527 2.0

Left Tilt 0.239 0.098 0.337 2.0

Right Touch 0.343 0.298 0.641 2.0

Right Tilt 0.224 0.183 0.407 2.0

Body-worn

Body back 0.481 0.200 0.681 2.0

GPRS-2slots 0.635 0.200 0.835 2.0

GPRS-3slots 0.674 0.200 0.874 2.0

GPRS-4slots 0.871 0.200 1.071 2.0

Body Front 0.737 0.167 0.904 2.0

Earphone 0.900 0.167 1.067 2.0

DCS 1800

Head (voice)

Left Touch 0.192 0.098 0.290 2.0

Left Tilt 0.066 0.098 0.164 2.0

Right Touch 0.136 0.298 0.434 2.0

Right Tilt 0.067 0.183 0.250 2.0

Body-worn

Body back 0.586 0.200 0.786 2.0

GPRS-2slots 0.494 0.200 0.694 2.0

GPRS-3slots 0.849 0.200 1.049 2.0

GPRS-4slots 0.926 0.200 1.126 2.0

Body Front 0.922 0.167 1.089 2.0

Earphone 0.833 0.167 1.000 2.0

WCDMA Band I

Head

Left Touch 0.177 0.098 0.275 2.0

Left Tilt 0.051 0.098 0.149 2.0

Right Touch 0.118 0.298 0.416 2.0

Right Tilt 0.058 0.183 0.241 2.0

Body-worn

Body back 0.332 0.200 0.532 2.0

Body Front 1.291 0.167 1.458 2.0

Body back 0.826 0.200 1.026 2.0

Earphone 1.240 0.167 1.407 2.0

WCDMA Band VIII

Head

Left Touch 0.274 0.098 0.372 2.0

Left Tilt 0.151 0.098 0.249 2.0

Right Touch 0.260 0.298 0.558 2.0

Right Tilt 0.112 0.183 0.295 2.0

Body-worn

Body back 0.378 0.200 0.578 2.0

Body Front 0.332 0.167 0.499 2.0

Body back 0.343 0.200 0.543 2.0

Earphone 0.347 0.167 0.514 2.0

Report No.: AGC00377160401EH01 Page 45 of 114

APPENDIX A. SAR SYSTEM CHECK DATA Test Laboratory: AGC Lab Date: Apr. 25,2016 System Check Head 900 MHz DUT: Dipole 900 MHz Type: SID 900 Communication System: CW; Communication System Band: D900 (900.0 MHz); Duty Cycle: 1:1; Frequency: 900 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section; Input Power=18dBm Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) Configuration/System Check 900MHz Head /Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.818 W/kg Configuration/System Check 900MHz Head / Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 22.963 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.983 W/kg SAR(1 g) = 0.655 W/kg; SAR(10 g) = 0.426 W/kg Maximum value of SAR (measured) = 0.830 W/kg

Report No.: AGC00377160401EH01 Page 46 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 System Check Head 1800MHz DUT: Dipole 1800 MHz; Type: SID 1800 Communication System: CW; Communication System Band: D1800 (1800.0 MHz); Duty Cycle: 1:1; Frequency: 1800 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section; Input Power=18dBm Ambient temperature (℃):22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Configuration/System Check 1800MHz Head/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.05 W/kg Configuration/System Check 1800MHz Head/ Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 49.074 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 4.21 W/kg SAR(1 g) = 2.39 W/kg; SAR(10 g) = 1.33 W/kg Maximum value of SAR (measured) = 3.00 W/kg

Report No.: AGC00377160401EH01 Page 47 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 System Check Head 2000MHz DUT: Dipole 2000 MHz; Type: SID 2000 Communication System: CW; Communication System Band: D2000 (2000.0 MHz); Duty Cycle: 1:1; Frequency: 2000 MHz; Medium parameters used: f = 1900 MHz; ζ=1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section; Input Power=18dBm Ambient temperature (℃):21.9, Liquid temperature (℃): 21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) Configuration/System Check 2000MHz Head / Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.25 W/kg Configuration/System Check 2000MHz Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 50.755 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 4.63 W/kg SAR(1 g) = 2.52 W/kg; SAR(10 g) = 1.32 W/kg Maximum value of SAR (measured) = 3.21 W/kg

Report No.: AGC00377160401EH01 Page 48 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 System Check Head 2450 MHz DUT: Dipole 2450 MHz Type: D2450V2 Communication System: CW; Communication System Band: D2450 (2450.0 MHz); Duty Cycle: 1:1; Frequency: 2450 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Flat Section; Input Power=18dBm Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Configuration/System Check 2450MHz / Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.83 W/kg Configuration/System Check 2450MHz/ Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=7mm, dy=7mm, dz=5mm Reference Value = 49.442 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 6.52 W/kg SAR(1 g) = 3.13 W/kg; SAR(10 g) = 1.51 W/kg Maximum value of SAR (measured) = 4.63 W/kg

Report No.: AGC00377160401EH01 Page 49 of 114

APPENDIX B. SAR MEASUREMENT DATA Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Low-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 880.2 MHz; Medium parameters used: f = 900 MHz;ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.565 W/kg LEFT HEAD/L-C-L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.456 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 0.666 W/kg SAR(1 g) = 0.510 W/kg; SAR(10 g) = 0.374 W/kg Maximum value of SAR (measured) = 0.571 W/kg

Report No.: AGC00377160401EH01 Page 50 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.545 W/kg LEFT HEAD/L-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.933 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 0.715 W/kg SAR(1 g) = 0.503 W/kg; SAR(10 g) = 0.355 W/kg Maximum value of SAR (measured) = 0.569 W/kg

Report No.: AGC00377160401EH01 Page 51 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 High-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 914.8 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.309 W/kg LEFT HEAD/L-C-H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.021 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.375 W/kg SAR(1 g) = 0.283 W/kg; SAR(10 g) = 0.204 W/kg Maximum value of SAR (measured) = 0.317 W/kg

Report No.: AGC00377160401EH01 Page 52 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid- Tilt-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63 ; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.295 W/kg LEFT HEAD/L-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.380 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 0.335 W/kg SAR(1 g) = 0.272 W/kg; SAR(10 g) = 0.209 W/kg Maximum value of SAR (measured) = 0.297 W/kg

Report No.: AGC00377160401EH01 Page 53 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid -Touch-Right <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

RIGHT HEAD/R-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.465 W/kg RIGHT HEAD/R-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.321 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.546 W/kg SAR(1 g) = 0.416 W/kg; SAR(10 g) = 0.300 W/kg Maximum value of SAR (measured) = 0.466 W/kg

Report No.: AGC00377160401EH01 Page 54 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid-Tilt-Right <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63 ; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.286 W/kg RIGHT HEAD/R-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 6.820 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 0.320 W/kg SAR(1 g) = 0.260 W/kg; SAR(10 g) = 0.196 W/kg Maximum value of SAR (measured) = 0.284 W/kg

Report No.: AGC00377160401EH01 Page 55 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Low-Touch-Left <SIM 2> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 880.2 MHz; Medium parameters used: f = 900 MHz;ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-C-L 2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.507 W/kg LEFT HEAD/L-C-L 2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.553 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.608 W/kg SAR(1 g) = 0.458 W/kg; SAR(10 g) = 0.333 W/kg Maximum value of SAR (measured) = 0.515 W/kg

Report No.: AGC00377160401EH01 Page 56 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid- Body- Back (MS) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: GSM 900; Duty Cycle: 1:8.3; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/BACK/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.06 W/kg BODY/BACK/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 24.315 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 1.57 W/kg SAR(1 g) = 0.803 W/kg; SAR(10 g) = 0.421 W/kg Maximum value of SAR (measured) = 0.972 W/kg

Report No.: AGC00377160401EH01 Page 57 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GPRS 900 Mid- Body- Back (2up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -2 Slot; Communication System Band: GSM900; Duty Cycle: 1:4.2; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/2ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.44 W/kg BODY/2ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 28.508 V/m; Power Drift = -0.00 dB Peak SAR (extrapolated) = 2.16 W/kg SAR(1 g) = 1.1 W/kg; SAR(10 g) = 0.575 W/kg Maximum value of SAR (measured) = 1.33 W/kg

Report No.: AGC00377160401EH01 Page 58 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GPRS 900 Mid-Body-Back (3up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -3 Slot; Communication System Band: GSM 900; Duty Cycle: 1:2.8 ; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/3ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.58 W/kg BODY/3ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 28.999 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 2.33 W/kg SAR(1 g) = 1.19 W/kg; SAR(10 g) = 0.623 W/kg Maximum value of SAR (measured) = 1.44 W/kg

Report No.: AGC00377160401EH01 Page 59 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GPRS 900 Mid-Body-Back (4up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -4 Slot; Communication System Band: GSM 900; Duty Cycle: 1:2.1 ; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST 2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.25 W/kg BODY/4ST 2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 33.169 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 3.30 W/kg SAR(1 g) = 1.64 W/kg; SAR(10 g) = 0.838 W/kg Maximum value of SAR (measured) = 2.16 W/kg

Report No.: AGC00377160401EH01 Page 60 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid- Body- Front (4up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -4 Slot; Communication System Band: GSM 900; Duty Cycle: 1:2.1 ; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST-FRONT/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.28 W/kg BODY/4ST-FRONT/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 29.426 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 2.61 W/kg SAR(1 g) = 1.27 W/kg; SAR(10 g) = 0.709 W/kg Maximum value of SAR (measured) = 1.61 W/kg

Report No.: AGC00377160401EH01 Page 61 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid-Body- Back (4up) –with earphone <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -4 Slot; Communication System Band: GSM 900; Duty Cycle: 1:2.1 ; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST-EARPHONE/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.26 W/kg BODY/4ST-EARPHONE/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 33.289 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 3.37 W/kg SAR(1 g) = 1.68 W/kg; SAR(10 g) = 0.865 W/kg Maximum value of SAR (measured) = 2.20 W/kg

Report No.: AGC00377160401EH01 Page 62 of 114

Report No.: AGC00377160401EH01 Page 63 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 GSM 900 Mid- Body- Back (4up) –with earphone<SIM 2> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS -4 Slot; Communication System Band: GSM 900; Duty Cycle: 1:2.1 ; Frequency: 897.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.91 W/kg BODY/4ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 32.088 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 2.81 W/kg SAR(1 g) = 1.45 W/kg; SAR(10 g) = 0.756 W/kg Maximum value of SAR (measured) = 1.75 W/kg

Report No.: AGC00377160401EH01 Page 64 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Low-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1710.2 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.222 W/kg LEFT HEAD/L-C-L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.520 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 0.293 W/kg SAR(1 g) = 0.198 W/kg; SAR(10 g) = 0.127 W/kg Maximum value of SAR (measured) = 0.232 W/kg

Report No.: AGC00377160401EH01 Page 65 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.221 W/kg LEFT HEAD/L-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.266 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.295 W/kg SAR(1 g) = 0.199 W/kg; SAR(10 g) = 0.127 W/kg Maximum value of SAR (measured) = 0.233 W/kg

Report No.: AGC00377160401EH01 Page 66 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 High-Touch-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1784.8 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-C 2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.304 W/kg LEFT HEAD/L-C 2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.768 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.399 W/kg SAR(1 g) = 0.262 W/kg; SAR(10 g) = 0.164 W/kg Maximum value of SAR (measured) = 0.306 W/kg

Report No.: AGC00377160401EH01 Page 67 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Tilt-Left <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.0982 W/kg LEFT HEAD/L-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.435 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 0.193 W/kg SAR(1 g) = 0.093 W/kg; SAR(10 g) = 0.057 W/kg Maximum value of SAR (measured) = 0.113 W/kg

Report No.: AGC00377160401EH01 Page 68 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Touch-Right <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

RIGHT HEAD/R-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.196 W/kg RIGHT HEAD/R-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.137 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.277 W/kg SAR(1 g) = 0.183 W/kg; SAR(10 g) = 0.118 W/kg Maximum value of SAR (measured) = 0.211 W/kg

Report No.: AGC00377160401EH01 Page 69 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Tilt-Right <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

RIGHT HEAD/R-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.106 W/kg RIGHT HEAD/R-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.064 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.139 W/kg SAR(1 g) = 0.091 W/kg; SAR(10 g) = 0.058 W/kg

Report No.: AGC00377160401EH01 Page 70 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 High-Touch-Left <SIM 2> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1784.8 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.228 W/kg LEFT HEAD/L-C-H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.475 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 0.309 W/kg SAR(1 g) = 0.207 W/kg; SAR(10 g) = 0.131 W/kg Maximum value of SAR (measured) = 0.239 W/kg

Report No.: AGC00377160401EH01 Page 71 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Body- Back (MS) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: Generic GSM; Communication System Band: DCS 1800; Duty Cycle: 1:8.3; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/BACK/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.984 W/kg BODY/BACK/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 17.235 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.66 W/kg SAR(1 g) = 0.894 W/kg; SAR(10 g) = 0.508 W/kg Maximum value of SAR (measured) = 1.11 W/kg

Report No.: AGC00377160401EH01 Page 72 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 GPRS 1800 Mid-Body- Back (2up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-2 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:4.2; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/2ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.822 W/kg BODY/2ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.158 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.32 W/kg SAR(1 g) = 0.751 W/kg; SAR(10 g) = 0.442 W/kg Maximum value of SAR (measured) = 0.911 W/kg

Report No.: AGC00377160401EH01 Page 73 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 GPRS 1800 Mid-Body- Back (3up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-3 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:2.8; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/3ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.53 W/kg BODY/3ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 25.982 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 2.50 W/kg SAR(1 g) = 1.38 W/kg; SAR(10 g) = 0.803 W/kg Maximum value of SAR (measured) = 1.69 W/kg

Report No.: AGC00377160401EH01 Page 74 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 GPRS 1800 Mid-Body- Back (4up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-4 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:2.1; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.77 W/kg BODY/4ST/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 23.813 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 2.80 W/kg SAR(1 g) = 1.60 W/kg; SAR(10 g) = 0.899 W/kg Maximum value of SAR (measured) = 1.88 W/kg

Report No.: AGC00377160401EH01 Page 75 of 114

Report No.: AGC00377160401EH01 Page 76 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Body- Front (4up) <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-4 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:2.1; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/4ST -FRONT/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.58 W/kg BODY/4ST -FRONT/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 16.173 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 3.02 W/kg SAR(1 g) = 1.59 W/kg; SAR(10 g) = 0.895 W/kg Maximum value of SAR (measured) = 1.99 W/kg

Report No.: AGC00377160401EH01 Page 77 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Body- Back (4up) –with earphone <SIM 1> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-4 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:2.1; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST -ERAPHONE/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.51 W/kg BODY/4ST -ERAPHONE/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 25.409 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 2.47 W/kg SAR(1 g) = 1.38 W/kg; SAR(10 g) = 0.808 W/kg Maximum value of SAR (measured) = 1.68 W/kg

Report No.: AGC00377160401EH01 Page 78 of 114

Test Laboratory: AGC Lab Date: Apr. 23,2016 DCS 1800 Mid-Body- Back (4up) <SIM 2> DUT: Smart Phone; Type: RAINBOW Communication System: GPRS-4 Slot; Communication System Band: DCS 1800; Duty Cycle: 1:2.1; Frequency: 1747.4 MHz; Medium parameters used: f = 1800 MHz; ζ= 1.43 mho/m; εr =40.35; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 22.0, Liquid temperature (℃): 21.9 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.28, 5.28, 5.28); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

BODY/4ST 2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.33 W/kg BODY/4ST 2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 25.126 V/m; Power Drift = -0.00 dB Peak SAR (extrapolated) = 2.09 W/kg SAR(1 g) = 1.2 W/kg; SAR(10 g) = 0.720 W/kg Maximum value of SAR (measured) = 1.44 W/kg

Report No.: AGC00377160401EH01 Page 79 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Low-Touch-Left (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ; Duty Cycle: 1:1; ;

Frequency: 1922.4MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-C -L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.284 W/kg LEFT HEAD/L-C -L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.807 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.436 W/kg SAR(1 g) = 0.272 W/kg; SAR(10 g) = 0.164 W/kg Maximum value of SAR (measured) = 0.319 W/kg

Report No.: AGC00377160401EH01 Page 80 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid-Touch-Left (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ; Duty Cycle: 1:1; ;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.330 W/kg LEFT HEAD/L-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.975 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 0.457 W/kg SAR(1 g) = 0.285 W/kg; SAR(10 g) = 0.174 W/kg Maximum value of SAR (measured) = 0.340 W/kg

Report No.: AGC00377160401EH01 Page 81 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I High-Touch-Left (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ; Duty Cycle: 1:1; ;

Frequency: 1977.6MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

LEFT HEAD/L-C -H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.241 W/kg LEFT HEAD/L-C -H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.011 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 0.363 W/kg SAR(1 g) = 0.223 W/kg; SAR(10 g) = 0.134 W/kg Maximum value of SAR (measured) = 0.267 W/kg

Report No.: AGC00377160401EH01 Page 82 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid-Tilt-Left (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.0842 W/kg LEFT HEAD/L-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.381 V/m; Power Drift = 0.17 dB Peak SAR (extrapolated) = 0.144 W/kg SAR(1 g) = 0.077 W/kg; SAR(10 g) = 0.050 W/kg Maximum value of SAR (measured) = 0.0905 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 83 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid-Touch-Right (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.190 W/kg RIGHT HEAD/R-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.747 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.268 W/kg SAR(1 g) = 0.180 W/kg; SAR(10 g) = 0.116 W/kg Maximum value of SAR (measured) = 0.207 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 84 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid-Tilt-Right <RMC> DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.0952 W/kg RIGHT HEAD/R-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.465 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.149 W/kg SAR(1 g) = 0.090 W/kg; SAR(10 g) = 0.057 W/kg Maximum value of SAR (measured) = 0.105 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 85 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid-Body-Towards Grounds (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/1/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.750 W/kg BODY/1/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.988 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.29 W/kg SAR(1 g) = 0.634 W/kg; SAR(10 g) = 0.327 W/kg Maximum value of SAR (measured) = 0.730 W/kg

Report No.: AGC00377160401EH01 Page 86 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Low- Body- Towards Phantom (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1922.4MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/2-L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm. Maximum value of SAR (measured) = 2.21 W/kg BODY/2-L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.201 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 4.63 W/kg SAR(1 g) = 2.2 W/kg; SAR(10 g) = 1.05 W/kg Maximum value of SAR (measured) = 2.84 W/kg

Report No.: AGC00377160401EH01 Page 87 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid- Body- Towards Phantom (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.56 W/kg BODY/2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.001 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 5.52 W/kg SAR(1 g) = 2.7 W/kg; SAR(10 g) = 1.27 W/kg Maximum value of SAR (measured) = 3.35 W/kg

Report No.: AGC00377160401EH01 Page 88 of 114

Report No.: AGC00377160401EH01 Page 89 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I High- Body- Towards Phantom (RMC) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1977.6MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/2-H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.12 W/kg BODY/2-H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 17.580 V/m; Power Drift = 0.16 dB Peak SAR (extrapolated) = 4.62 W/kg SAR(1 g) = 2.15 W/kg; SAR(10 g) = 1.01 W/kg Maximum value of SAR (measured) = 2.78 W/kg

Report No.: AGC00377160401EH01 Page 90 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid- Body- Towards Grounds (HSPA) DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/3/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.86 W/kg BODY/3/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.663 V/m; Power Drift = 0.19 dB Peak SAR (extrapolated) = 2.85 W/kg SAR(1 g) = 1.5 W/kg; SAR(10 g) = 0.805 W/kg Maximum value of SAR (measured) = 1.93 W/kg

Report No.: AGC00377160401EH01 Page 91 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Low- Body- Towards Phantom (RMC) –with earphone DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1922.4MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/4 -L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.37 W/kg BODY/4 -L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.161 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 5.78 W/kg SAR(1 g) = 2.53 W/kg; SAR(10 g) = 1.18 W/kg Maximum value of SAR (measured) = 3.37 W/kg

Report No.: AGC00377160401EH01 Page 92 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I Mid- Body- Towards Phantom (RMC) –with earphone DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1950MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/4/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.37 W/kg BODY/4/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.161 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 5.78 W/kg SAR(1 g) = 2.59 W/kg; SAR(10 g) = 1.22 W/kg Maximum value of SAR (measured) = 3.39 W/kg

Report No.: AGC00377160401EH01 Page 93 of 114

Test Laboratory: AGC Lab Date: Apr. 21,2016 WCDMA Band I High- Body- Towards Phantom (RMC) –with earphone DUT: Smart Phone; Type: RAINBOW

Communication System: UMTS; Communication System Band: BandⅠUTRA/FDD ;Duty Cycle:1:1;

Frequency: 1977.6MHz; Medium parameters used: f = 1900 MHz; ζ= 1.39 mho/m; εr =41.05; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃):21.9, Liquid temperature (℃):21.3 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(5.23, 5.23, 5.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/4 -H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.37 W/kg BODY/4 -H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.161 V/m; Power Drift = 0.01dB Peak SAR (extrapolated) = 5.78 W/kg SAR(1 g) = 2.50 W/kg; SAR(10 g) = 1.16 W/kg Maximum value of SAR (measured) = 3.31 W/kg

Report No.: AGC00377160401EH01 Page 94 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Low-Touch-Left (RMC ) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 882.4 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.314 W/kg LEFT HEAD/L-C-L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.165 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.385 W/kg SAR(1 g) = 0.284 W/kg; SAR(10 g) = 0.204 W/kg Maximum value of SAR (measured) = 0.321 W/kg

Report No.: AGC00377160401EH01 Page 95 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Touch-Left (RMC ) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.377 W/kg LEFT HEAD/L-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.611 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.457 W/kg SAR(1 g) = 0.334 W/kg; SAR(10 g) = 0.237 W/kg

Report No.: AGC00377160401EH01 Page 96 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII High-Touch-Left (RMC ) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 912.6 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C-H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.246 W/kg LEFT HEAD/L-C-H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 6.314 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.306 W/kg SAR(1 g) = 0.223 W/kg; SAR(10 g) = 0.159 W/kg Maximum value of SAR (measured) = 0.253 W/kg

Report No.: AGC00377160401EH01 Page 97 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid- Tilt-Left (RMC) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Left Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.189 W/kg LEFT HEAD/L-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.173 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 0.214 W/kg SAR(1 g) = 0.172 W/kg; SAR(10 g) = 0.131 W/kg Maximum value of SAR (measured) = 0.188 W/kg

Report No.: AGC00377160401EH01 Page 98 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid- Touch-Right (RMC) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6MHz;; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.346 W/kg RIGHT HEAD/R-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.296 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 0.443 W/kg SAR(1 g) = 0.321 W/kg; SAR(10 g) = 0.225 W/kg Maximum value of SAR (measured) = 0.360 W/kg

Report No.: AGC00377160401EH01 Page 99 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Tilt-Right (RMC) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6 MHz; Medium parameters used: f = 900 MHz; ζ=0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Right Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.169 W/kg RIGHT HEAD/R-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.721 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.246 W/kg SAR(1 g) = 0.137 W/kg; SAR(10 g) = 0.097 W/kg Maximum value of SAR (measured) = 0.159 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 100 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Body-Towards Grounds (RMC) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6MHz; Medium parameters used: f = 900 MHz; ζ= 0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/1/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.750 W/kg BODY/1/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.988 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.29 W/kg SAR(1 g) = 0.634 W/kg; SAR(10 g) = 0.327 W/kg. Maximum value of SAR (measured) = 0.730 W/kg

Report No.: AGC00377160401EH01 Page 101 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Body-Towards Phantom (RMC) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6 MHz; Medium parameters used: f = 900 MHz; ζ= 0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/2/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.647 W/kg BODY/2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.819 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.12 W/kg SAR(1 g) = 0.527 W/kg; SAR(10 g) = 0.287 W/kg. Maximum value of SAR (measured) = 0.612 W/kg

Report No.: AGC00377160401EH01 Page 102 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Body-Towards Ground (HSPA) DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6MHz; Medium parameters used: f = 900 MHz; ζ= 0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/3/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.691 W/kg BODY/3/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.549 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.17 W/kg SAR(1 g) = 0.582 W/kg; SAR(10 g) = 0.303 W/kg Maximum value of SAR (measured) = 0.667 W/kg

Report No.: AGC00377160401EH01 Page 103 of 114

Test Laboratory: AGC Lab Date: Apr. 25,2016 WCDMA Band VIII Mid-Body-Towards Grounds (RMC) - with earphone DUT: Smart Phone; Type: RAINBOW Communication System: UMTS; Communication System Band: BAND VIII UTRA/FDD; Duty Cycle:1:1; Frequency: 897.6 MHz; Medium parameters used: f = 900 MHz; ζ= 0.96 mho/m; εr =41.63; ρ= 1000 kg/m³ ; Phantom section: Flat Section Ambient temperature (℃): 21.3, Liquid temperature (℃): 21.4 DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(6.23, 6.23, 6.23); Calibrated:10/01/2015; • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/4/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.636 W/kg BODY/4/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 20.492 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 1.08 W/kg SAR(1 g) = 0.559 W/kg; SAR(10 g) = 0.300 W/kg Maximum value of SAR (measured) = 0.661 W/kg

Report No.: AGC00377160401EH01 Page 104 of 114

WIFI MODE Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid-Touch-Left DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Left Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.161 W/kg LEFT HEAD/L-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.410 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 0.326 W/kg SAR(1 g) = 0.151 W/kg; SAR(10 g) = 0.077 W/kg Maximum value of SAR (measured) = 0.176 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 105 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid -Tilt-Left DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Left Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) LEFT HEAD/L-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.175 W/kg LEFT HEAD/L-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.680 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 0.430 W/kg SAR(1 g) = 0.165 W/kg; SAR(10 g) = 0.077 W/kg Maximum value of SAR (measured) = 0.204 W/kg

The second hotspot is within 2dB, but the first hotspot is outside the 2dB of the SAR compliance limit.

Report No.: AGC00377160401EH01 Page 106 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Low- Touch-Right DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2412 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Right Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-C-L/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.830 W/kg RIGHT HEAD/R-C-L/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.096 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.63 W/kg SAR(1 g) = 0.538 W/kg; SAR(10 g) = 0.207 W/kg Maximum value of SAR (measured) = 0.674 W/kg

Report No.: AGC00377160401EH01 Page 107 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid- Touch-Right DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Right Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-C/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.793 W/kg RIGHT HEAD/R-C/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.983 V/m; Power Drift = -0.09dB Peak SAR (extrapolated) = 1.80 W/kg SAR(1 g) = 0.594 W/kg; SAR(10 g) = 0.234 W/kg Maximum value of SAR (measured) = 0.818 W/kg

Report No.: AGC00377160401EH01 Page 108 of 114

Report No.: AGC00377160401EH01 Page 109 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b High- Touch-Right DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2472 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Right Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-C-H/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.635 W/kg RIGHT HEAD/R-C-H/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.844 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 1.22 W/kg SAR(1 g) = 0.416 W/kg; SAR(10 g) = 0.164 W/kg Maximum value of SAR (measured) = 0.511 W/kg

Report No.: AGC00377160401EH01 Page 110 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid-Tilt-Right DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Right Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) RIGHT HEAD/R-T/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.472 W/kg RIGHT HEAD/R-T/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 6.074 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.685 W/kg SAR(1 g) = 0.314 W/kg; SAR(10 g) = 0.144 W/kg Maximum value of SAR (measured) = 0.478 W/kg

Report No.: AGC00377160401EH01 Page 111 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid-Body-Worn- Back (MS) DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Flat Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/BACK/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.499 W/kg BODY/BACK/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.946 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.14 W/kg SAR(1 g) = 0.392 W/kg; SAR(10 g) = 0.157 W/kg Maximum value of SAR (measured) = 0.446 W/kg

Report No.: AGC00377160401EH01 Page 112 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid-Body- Worn- Front (MS) DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Flat Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/FRONT/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.296 W/kg BODY/FRONT/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 7.169 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.852 W/kg SAR(1 g) = 0.317 W/kg; SAR(10 g) = 0.131 W/kg Maximum value of SAR (measured) = 0.420 W/kg

Report No.: AGC00377160401EH01 Page 113 of 114

Test Laboratory: AGC Lab Date: Apr. 22,2016 802.11b Mid-Body- Worn- Back (MS) –with earphone DUT: Smart Phone; Type: RAINBOW Communication System: Wi-Fi; Communication System Band: 802.11b; Duty Cycle: 1:1; Frequency: 2442 MHz; Medium parameters used: f = 2450 MHz; ζ =1.81 mho/m; εr =39.99; ρ= 1000 kg/m³ ; Phantom section: Flat Section

Ambient temperature (℃):21.3, Liquid temperature (℃): 21.9

DASY Configuration: • Probe: ES3DV3 – SN3337; ConvF(4.66, 4.66, 4.66); Calibrated:10/01/2015 • Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0 • Electronics: DAE4 SN1398; Calibrated: 02/02/2016 • Phantom: SAM (20deg probe tilt) with CRP v5.0; Type: QD000P40CD; • DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164) BODY/EARPHONE/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.379 W/kg BODY/EARPHONE/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 2.939 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.24 W/kg SAR(1 g) = 0.327 W/kg; SAR(10 g) = 0.131 W/kg Maximum value of SAR (measured) = 0.365 W/kg

Report No.: AGC00377160401EH01 Page 114 of 114