Industry, medicine, supply engineering or
research, the fields of application and
quantities of industrial gases consumed vary
immensely.
Consequently, the most important factor for
a successful gas supplier is the location of
the production site, either as on-site gas
generation or a central plant with a pipeline
network. This flexibility and the strict techni-
cal regulations require constructions that
exceed the limits of standard produc ts. As
a result, the SAMSON product range in-
cludes cryogenic valves, pressure regulators
and level meters developed specifically for
these areas of application.
For example, temperatures as low as
–196 °C are typical in cold boxes used for
cryogenic air separation. Huge demands
are placed on valve material, sealing abil-
ity and the protection used to prevent the
valve from icing up.
Cryogenic plants: air separation
Designed to keep cool
Type 3246 and Type 3248 Cryogenic ValvesThe cryogenic valves provide the following advantages:
•Anymountingpositionpossible
•Globe-styleorangle-stylevalvebody
•Overallheightandendconnectionsaccordingto customer specifications
•DINorANSIversions
•Bellowssealtopreventheatconductioninthevalve space and the valve stem from freezing up
•Backupstuffingbox
•Valvebodymadeofcold-resistingstainlesssteel or aluminum
•Seat/plugtrimcanbereplacedwithout disassembling the valve
•Easy-to-useseattool
•Transportcapstoprotectthecoverflangeindisassembled condition
Type 3730 Positioner for use with cryogenic
valves
Seat/plug trim
Areas of application: research in a cryogenic wind tunnel
Oxygen for steel production
Designed to keep cool
Safety and quality are paramount for in-
dustrial gas suppliers. They rely on state-
of-the-art technology when transporting
industrial gas by road. The difficult operat-
ing conditions at pressures reaching 40 bar
and at temperatures as low as –196 °C
make the use of special control valves
necessary.
Transport: taking no risks
The self-operated Type 2357 Pressure
Regulators easily meet the requirements in
the distribution of cryogenic gases.
The reliable functioning of the regulator
24 hours a day – whether operated at full or
part capacity – is decisive for the competitive-
ness of a plant. Surfaces can be electropol-
ished to meet highest purity requirements.
Gas at the right time and place
Type 2357-2 Excess Pressure Valve•Usedaseconomizer
•Additionalnon-returnunit
•VersionforPN50TÜVtypetested
•Integratedstrainer
Type 2357-1 Pressure Build-up Regulator•Fail-safefunction
•Canalsobeusedaspressurereducingvalve
•Versionforultra-puregasservice (Type 2357-6 with wetted parts made of stainless steel)
•Integratedstrainer
Type 2357-3 Pressure Build-up Regulator•Fail-safefunction
•Unitesthefunctionsofexcesspressurevalveand pressure build-up regulator
•Additionalnon-returnunit
•KVS 3.2
•Integratedstrainer
Stainless steel body of the pressure build-up regulator
Soft-seated plug with bellows
Self-operated regulators maintain the right pressure
Always up-to-date
The first step to minimize transport costs is
to make distribution more efficient. A tank
management system helps save time and
money. Tank levels and pressures are
monitored remotely from a central control
station. This ensures supply-oriented and
on-time delivery as well as continuous
safety monitoring.
The Media 6 meter with its associated te-
lemetry system sends data polled at regular
intervals to the supply scheduling system.
Besidesthetanklevel,limitvaluesandfaults
are indicated.
The modular design of the Media series
allows the attachment of valve blocks, op-
erating pressure gauges and limit switches
as required.
Tank level: control and remote monitoring
Reliable tank data and expert logistics ensure
an optimal supply
Media 6 Differential Pressure Meter•Microprocessorcontrolled
•Digitaldisplaydownto–40°Cwith100%bargraph as well as alarm and warning markers
•Savesuptofourdifferentgastypesandtankshape
•Switchestoselectthegastype
•Measuringrangesupto3600mbar
•Adjustmentofmeasuringspan1:5
•Keysforzeropointandmeasuringspan adjustment
•Twosoftwarelimitswitches
Media 5 Differential Pressure Meter•160mmindicatordiameter
•Scalemarkingaccordingtocustomer specifications
•Measuringrangesupto3600mbar
•Adjustmentofmeasuringspan1:2
•Zeropointadjustmentatthefront
•Optionalthreelimitswitches
•Modulardesign
Media 05 Differential Pressure Meter•100mmindicatordiameter
•Scalesmarkingaccordingtocustomer specifications
•Measuringrangesupto3600mbar
•Adjustmentofmeasuringspan1:1.6
•Zeropointadjustmentatthefront
•Optionaltwolimitswitches
•Modulardesign
2009-03HD·WA76EN
SAMSONAG·MESS-UNDREGELTECHNIK·Weismüllerstraße3·60314FrankfurtamMain·GermanyPhone:+49694009-0·Fax:+49694009-1507·E-mail:[email protected]·Internet:www.samson.de