Salesian College Student Services & Admin Redevelopment · PDF fileSeptember 2017 1:1000 @ A1...

15
00 01 02 03 04 05 06 07 08 09 10 11 Cover Page Site Campus Plan Existing Site Plan Proposed Site Plan Existing & Demolition Plans Existing & Demolition Elevations Proposed Ground Floor Plan Proposed First Floor Plan Proposed Roof Plan Proposed Elevations Proposed Section and South Elevation Perspective Views Salesian College Student Services & Admin Redevelopment Town Planning September 2017 Architect - Williams Ross Architects Suite 1, 70 Kerr Street Fitzroy Vic 3065 Ph 03 9416 3044 Structure - Acor Kersulting Level 1, 173 Burke Road Glen Iris VIC 3146 Ph 03 9885 4335 Civil Engineers - Acor Kersulting Level 1, 173 Burke Road Glen Iris VIC 3146 Ph 03 9885 4335 Services Enginers - BRT 159 Victoria Parade Collingwood Vic 3003 Ph 03 9417 5851 Hydraulic Engineers - BRT 159 Victoria Parade Collingwood Vic 3003 Ph 03 9417 5851 Building Surveyor - Philip Chun & Associates Pty Ltd Level 2 120 Jolimont Rd Jolimont, Vic, 3002 PH 03 9662 2200 Landscape Architect - MDG Landscape Architects 2nd Floor 45 Victoria Avenue Albert Park, Vic 3206 Ph 03 9696 4957 Attachment 1: 10 Bosco Street, Chadstone

Transcript of Salesian College Student Services & Admin Redevelopment · PDF fileSeptember 2017 1:1000 @ A1...

TP TOWN PLANNING000102030405060708091011

Cover PageSite Campus PlanExisting Site PlanProposed Site PlanExisting & Demolition PlansExisting & Demolition ElevationsProposed Ground Floor PlanProposed First Floor PlanProposed Roof PlanProposed ElevationsProposed Section and South ElevationPerspective Views

Salesian College

Student Services & AdminRedeve lopment

Town PlanningSeptember 2017

Architect - Williams Ross ArchitectsSuite 1, 70 Kerr StreetFitzroy Vic 3065Ph 03 9416 3044

Structure - Acor KersultingLevel 1, 173 Burke RoadGlen IrisVIC 3146Ph 03 9885 4335

Civil Engineers - Acor KersultingLevel 1, 173 Burke RoadGlen IrisVIC 3146Ph 03 9885 4335

Services Enginers - BRT159 Victoria ParadeCollingwoodVic 3003Ph 03 9417 5851

Hydraulic Engineers - BRT159 Victoria ParadeCollingwoodVic 3003Ph 03 9417 5851

Building Surveyor - Philip Chun & Associates Pty LtdLevel 2120 Jolimont RdJolimont, Vic, 3002PH 03 9662 2200

Landscape Architect - MDG Landscape Architects2nd Floor45 Victoria AvenueAlbert Park, Vic 3206Ph 03 9696 4957

Attachment 1: 10 Bosco Street, Chadstone

01September 2017 1:1000 @ A1 1715

Site Campus Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

UPUP

UPUP

UPUP

UPUP

DN

DN

MONASH FREEWAY

BARA

DINE

ST.

WAVERLEY RD.

BOSC

O ST

.

SAVI

O ST

.

JACA

NA S

T.

ROSEMARY ST.

HISC

OCK

ST.

JACANA ST.

TIMMINGS ST.

EVANS ST.

BECKETT ST.

HISC

OCK

ST.

JACA

NA S

T.

ENTRYPARKING

EXIT

TENNIS

TENNIS

NETS

OVAL

BOSCO PLAZA CENTRAL COURTYARD

NEW BUILDINGEXTENSION

(SUBJECT SITE)

SALESIAN COLLEGEBOSCO CAMPUS

Location of proposed building works

Location of proposed carpark works

Campus Plan1:1000

Location MapNot to scale

Aerial photo of subject site

Location of New Building Extension

Location of Carparking and Landscape works

02September 20171:200, 1:8.96 @A1 1715

Existing Site Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

79.5

8 0

8 0 .5

Bo

sco

St

Sav

io S

t.

E X I S T I N G C O N C R E T E D R I V E W A Y

E X I S T I N G C O N C R E T E P A T HE X I S T I N G C O N C R E T E P A T H

E X I S T I N G C O N C R E T E D R I V E W A Y

E X I S T I N G C O L L E G E B U I L D I N G

S I T E B O U N D A R YS I T E B O U N D A R Y

Ex Tree24 exist ing grass paver car park

E X I S T I N G B O U N D A R Y P L A N T I N G T O R E M A I N

no park no park

Photo 1

2

1

3

Site Plan - Existing1:200

S U B J E C T S I T E

LEGEND

Existing buildings

Proposed works

Photo 2 Photo 3

2 Location of photos

Photo 4

4

03September 2017 1:200 @ A1 1715

Proposed Site Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

5,960 24,320

2,800 2,800 2,800 2,800

5,400

11,36

717

,700

79.5

8 0

8 0 .5

Bo

sco

St

Sav

io S

t.

B

E X I S T I N G C O N C R E T E D R I V E W A Y

E X I S T I N G C O N C R E T E D R I V E W A Y

E X I S T I N G C O L L E G E B U I L D I N G

to site boundary

S I T E B O U N D A R YS I T E B O U N D A R Y

N E W C O N C R E T E P A T H

BB

BB

B

Ex Tree

Ex TreeEx TreeEx Tree Ex Tree

New Admin Bui lding

New pavement to civi l &landscape design

24 car park with new asphlat surface & curbing(Including 2 accessible bays with shared bay)

E X I S T I N G B O U N D A R Y P L A N T I N G T O R E M A I N

24 car park with new asphlat surface & curbing(Including 2 accessible bays with shared bay)

Site Plan - Proposed1:200

LEGEND

Existing buildings

Proposed building works

Proposed paving and landscaping

04September 2017 1:200 @ A1 1715

Existing & Demolition Plans

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

+80.000

+79.850

+79.850

Remove existing concrete driveway surface forreplacement as part of new works.Extent and Levels to match existingCoordinate with Landscape Drawing

Remove existing concrete driveway surface forreplacement as part of new works.Extent and Levels to match existingCoordinate with Landscape Drawing

79.5

8 0

80.5

Proposed Building Footprint

Existing Verandah

Remove TreeRemove Tree

Remove existing colouredconcrete paving

Remove existing Grass Paver type car parksuface for replcement new works

Remove existing concrete pedestrian pathway

Remove existing Grass Paver type car parksuface for replcement new works

Remove existing pathincluding concrete kerb

Demolish entrysteps & porch over

Remove TreeRemove Tree

EXISTING CONCRETE DRIVEWAY (hatched) to remain

EXISTING CONCRETE DRIVEWAY (hatched) to remain

Existing Lawn (grassed area) to remain

Existing TreeProtect & retainExisting Tree

Protect & retain

Existing TreeProtect & retainExisting Tree

Protect & retain

Existing TreeProtect & retain

60,500

17,70

0

L1 Existing / Demolition Plan1:200

LEGEND

Existing buildings

Proposed building footprint

Elements to be demolished

05September 20171:100, 1:6.78 @A1 1715

Existing & Demolition Elevations

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

FFL 80.000 AHDFFL 80.000 AHDFFL 80.000 AHD

FFL 84.090 AHD

Windows to be removed to allow forconnection to proposed building in foreground.

Windows to be removed to allow forconnection to proposed building in foreground. Windows to be removed to allow for

connection to proposed building in foreground.

Tree to be removed

Tree to be removed

Demolish porch & smallbalcony.

FFL 84.090 AHD

FFL 80.000 AHD

Windows to be removed and openings bricked up.Doorways to be removed and openings bricked up.

North Elevation - Demolition1:100E1

South Elevation - Demolition1:100E4

Remove trees

Remove blacony

Remove window

06September 2017 1:1, 1:100 @ A1 1715

Proposed Ground Floor Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

E505

5,960 24,320

11,36

711

,367

17,70

0

+80.000

+79.850

+79.850

S207

E106

E206 E3 06

New window anddoor in exsiting wall

RET. WAL L

P A T H

B R I C KB R I C K

8 0

seat

1 i n 2 0 w a l k w a y

garden bed

Ex Tree

Ex Tree

r a m p

ram

p

ex st

airs

Ex Tree

gard

en be

d

p/c

E X I S T I N GC A R P A R K I N G

seat

B o l l a r d

Existing Verandah

to East college boundary60,500

up

up

up

low wall

New paving - waiting zone

Exsiting Driveway

Porch

BB

BB

B

New Path

New carpark surface and kerbing

New surface to Driveway entrance -refer to landscape drawings.

Extent and levels to match existing.

Existing Tree

Landscape planting Landscape planting

to No

rth co

llege

boun

dary

17,70

0

ExistingNo New Works

ExistingNo New Works

2 x N e w a c c e s s i b l e c a rs p a c e s

E X I S T I N GC A R P A R K I N G

E X I S T I N GG A T E S

REFURBISHEDAREA

NewLearningSpace

NewLearningSpace

Deputy15 m2A.P. Students

14 m2

R.E Office18 m2

A.P. Faith &Mission

P.A16 m2

Admin12 m2 Acc WC

6 m2

Reception13 m2

Accnts9 m2

Foyer33 m2

Corridor36 m2

Corridor58 m2

Air Lock6 m2

A.P.Organisation

Lobby

Acc WC

StudentReception

StudentServices

Lobby

A.P. Careers Youth

Council

Youth

NewLearningSpace

LS Office

LS Office

Interview

Meeting

L.S. Office14 m2

2,616

2,800 2,800 2,800

5400

ex seatex seat

EXISTING 1.8 HIGH TIMBER PALING FENCE

E X I S T I N G P L A N T I N G T O R E M A I N

E X I S T I N G S I N G L E S T O R E Y B R I C K V E N E E R R E S I D E N C E

INDICATIVE TITLE BOUNDARY

EXIST

ING BU

ILDING

Meeting17 m2

Debtor9 m2

PrincipalsOffice

21 m2

Interview Sick Bay Interview

LearningSupport

LEGEND

Existing buildings

Proposed building works

Proposed paving works

A

Proposed existing area to be refurbished

Rev A 16/11/2017 Context & information added

07September 2017 1:1, 1:100 @ A1 1715

Proposed First Floor Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

E505

S207

E106

E206 E3 06

14,30

017

,200

30,900

17,10

0

+83.015+84.090

+83.015 +84.090

Suspended College Crest

v oi d

v o i d

plant platform on roof over

College boundary

60,500to east college boundary

setba

ck fr

om bo

unda

ry

BOX GUTTER

3° F

ALL

W W W W W W W

W

WW

W

W

up

up

up

Existing LibraryNo New Works

DevelopOffice

22 m2

Head ofDevelop

11 m2

SchoolAccount

10 m2

B. Man Office16 m2

Copy10 m2 Male

17 m2

Acc WC6 m2

Female15 m2

Corridor22 m2

Lobby58 m2

Foyer37 m2

Comms5 m2

exis

ting

fir

e w

all

kitch

enett

e

Existing Staff RoomRefurbish

INDICATIVE TITLE BOUNDARY

Board Room43 m2

Meeting33 m2

LEGEND

A

Existing buildings

Proposed building works

Proposed paving works

Proposed existing area to be refurbished

Rev A 16/11/2017 Context & information added

08September 2017 1:100, 1:1 @ A1 1715

Proposed Roof Plan

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

E505

S207

E106

E206 E3 06

11,210 8,859

22,20

0

3° F

ALL

BOX GUTTER

Lift Overrun

Roof Plant

Roof Below

EXISTING ROOF BOX GUTTER

EXISTING ROOF BOX GUTTERRoof Below

EXISTING ROOF TO REMAINEXISTING ROOF TO REMAIN

EXISTING ROOF TO REMAINRoof Below

MR1

MR1

Plant Screen

Plan

t Scre

en

Plan

t Scre

en

7,140

4,971

Indicative location of plant equipment containedand concealed from view within roof top plantenclosure

EXISTING ROOF TO REMAIN

INDICATIVE TITLE BOUNDARY

MATERIAL PALETTE

MR1 Metal RoofingColour: Surfmist (White)

A

Rev A 16/11/2017 Context & information added

09September 2017 1:100, 1:1 @ A1 1715

Proposed Elevations

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

FFL 80.000 AHD

FFL 84.090 AHD

8,053

9,961

8,911

Steel plate reveals to windowperimeter to protrude 450 nom.

2m high double glazing (performance tomeet section J). Allow for colored glass to30%. nom.

Metal College artwork suspendedwithin facade opening.

Refer to landscape drawings for planting

BR1

LV

BR1

AR1

MF1

MF1GL GL

GL1 GL1

Plant screen beyond

FFL 80.000 AHD

FFL 84.090 AHD

9,048

10,84

8

Steel plate reveals to windowperimeter to protrude 450 nom.Perforated brickwork. Hit & miss pattern to

create opportunity for backlighting andviews from witin void & meeting roombehind.

BR1

MF1

BR1 MC1

LV

MF1

GL1

GL GL

Title

Boun

dry

Plant Screen

Steel plate reveals to windowperimeter to protrude 450 nom.

2m high double glazing (performance tomeet section J). Allow for colored glass to30%. nom.

AR1

LV

MF1

BR1

MC1 GLGL

GL1 GL1

MF1

Plant Screen

Title

Boun

dry

FFL 80.000 AHD

FFL 84.090 AHD9,890

8,090

L i b r a r y

MATERIAL PALETTE

Face Brickwork PressedColour: Earth White

BR1

MC1

AR1

MF1

TC1

Aluminium Composite Panel FRColour: Mid Grey

Applied Acrylic RenderColour: Charcoal Mid Grey

Steel Plate (welded)Colour: Black

Timber CladdingColour: Blackbutt (sealed)(location within Entry opening)

Glass - Viridian Low EColour: Neutral Grey

GL

Glass - Viridian Low EColour: Clear

GL1

Aluminium LouvresColour: Charcoal

LV

North Elevation - Proposed1:100E1

West Elevation - Proposed1:100E2

East Elevation - Proposed1:100E3

10September 2017 1:100, 1:1 @ A1 1715

Proposed Section and SouthElevation

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

3,000

3,000

1,090

1,800

4,300

4,000

8,500

10,30

0

FFL 80.000 AHD

FFL 84.090 AHD

E x i s t i n g B u i l d i n g N e w B u i l d i n g

lift overrrun

S c h o o l A c c o u n tF e m a l eE x i s t i n g L i b r a r y

Roof Plan Platform

R E O f f i c eI n t e r v i e wR e c e p t i o n C o r r i d o r

Title

Boun

dry

FFL 80.000 AHD

FFL 84.090 AHD

GL1

Openings bricked up.Bricks to match existing.

Openings bricked up.Bricks to match existing.

No change to upperexternal facade.

No change toexternal facade.

Plant Screen beyond

MATERIAL PALETTE

Face Brickwork PressedColour: Earth White

BR1

MC1

AR1

MF1

TC1

Aluminium Composite Panel FRColour: Mid Grey

Applied Acrylic RenderColour: Charcoal Mid Grey

Steel Plate (welded)Colour: Black

Timber CladdingColour: Blackbutt (sealed)(location within Entry opening)

Glass - Viridian Low EColour: Neutral Grey

GL

Glass - Viridian Low EColour: Clear

GL1

Aluminium LouvresColour: Charcoal

LV

Cross Section1:100S1

South Elevation - Proposed1:100E4

11September 2017 @ A1 1715

Perspective Views

Student Services & AdminRedevelopment

Salesian College

TOWN

PLAN

NING

S t u d e n t S e r v i c e s & A d m i n R e d e v e l o p m e n tE n t r y V i e w f r o m N o r t h E a s t

S t u d e n t S e r v i c e s & A d m i n R e d e v e l o p m e n tE x i t V i e w f r o m N o r t h W e s t

27/12/2017 2:28 pm

Attachment 2: 10 Bosco Street, Chadstone

Planning Overlays and Zones

Base data is supplied under Licence from Land Victoria. This map is for general use only and may not be used as proof ofownership, dimensions or any other status. The City of Monash endeavours to keep the information current, and welcomesnotification of omissions or inaccuracies.

1:7500

Address10 Bosco Street CHADSTONE VIC 3148

Attachment 3: 10 Bosco Street, Chadstone

Planning Overlays and Zones

Base data is supplied under Licence from Land Victoria. This map is for general use only and may not be used as proof ofownership, dimensions or any other status. The City of Monash endeavours to keep the information current, and welcomesnotification of omissions or inaccuracies.

7500

Address2B Swanson Crescent CHADSTONE VIC 3148