Sagem - Link F-H Microwave Installation and Operation Manual(2008)

134
SAGEM-LINK F-H - Release 1 Microwave Radio Links 6 GHz – 38 GHz Installation and Operation Manual 253 129 101-01 September 2008 Issue

Transcript of Sagem - Link F-H Microwave Installation and Operation Manual(2008)

Page 1: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H - Release 1

Microwave Radio Links

6 GHz – 38 GHz

Installation and Operation Manual

253 129 101-01

September 2008 Issue

Page 2: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 2/134 Sagem Communications document. Reproduction and disclosure prohibited

HANDBOOK CHANGE LIST

(Each new edition supersedes the previous edition)

No. Date Change description Page

253 129 101-01

(3000318486-R11-000-01)

September 2008

Initial release in original issue All pages

Page 3: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

WARNING

SAGEM Communications carefully monitors all technical changes and strives continuously to improve its products for the benefit of its customers.

It therefore reserves the right to change its documentation without prior notice.

All trademarks are registered by their owners.

ENVIRONMENT

Preservation of the environment as part of a sustainable development logic is an essential concern of Sagem Communications. The desire of Sagem Communications is to operate systems observing the environment and consequently it has decided to integrate environmental performances in the life cycle of its products, from manufacturing to commissioning, use and elimination. PACKAGING:

The presence of the logo (green dot) means that a contribution is paid to an approved national organisation to improve packaging recovery and recycling infrastructures.

B

I

T

IE

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 3/134

To facilitate recycling, please respect the sorting rules set up locally for this kind of waste.

ATTERIES:

f your product contains batteries, they must be disposed of at appropriate collection points.

HE PRODUCT:

The crossed-out waste bin stuck on the product (or on its accessories) means that the product belongs to the family of electrical and electronic equipment.

In this respect, the European regulations ask you to dispose of it selectively: • At sales points in the event of the purchase of similar equipment. • At the collection points made available to you locally (drop-off centre, selective

collection, etc.).

n this way you can participate in the re-use and upgrading of WEE (Waste Electrical and Electronic quipment), which can have an effect on the environment and human health.

Page 4: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 4/134 Sagem Communications document. Reproduction and disclosure prohibited

TABLE OF CONTENTS

1. INSTALLATION...........................................................................................................................................................10 1.1 - INTRODUCTION ........................................................................................................................................................10 1.2 - UNPACKING THE EQUIPMENT...................................................................................................................................10 1.3 - IDU INSTALLATION..................................................................................................................................................11 1.4 - ANTENNA INSTALLATION.........................................................................................................................................11

1.4.1 - Antenna mount .................................................................................................................................12 1.4.2 - Antenna Installation ..........................................................................................................................12

1.5 - ODU INSTALLATION ................................................................................................................................................13 1.5.1 - 1+0 Configuration with integrated antenna.......................................................................................13 1.5.2 - 1+0 Configuration with pole mount and standard antenna...............................................................14 1.5.3 - "Hot standby" 1+1 configuration with coupler and integrated antenna ............................................14 1.5.4 - 1+1 hot standby configuration with remote mounted coupler and standard antenna ......................15 1.5.5 - 1+1 space diversity configuration with 2 antennas...........................................................................16 1.5.6 - 1+1 frequency diversity configuration with remote mounts and dual polarized antenna .................16

1.6 - INSTALLING THE IDU TO ODU COAXIAL CABLE .....................................................................................................16 1.7 - CONNECTING THE IDU TO EXTERNAL EQUIPMENT ...................................................................................................17

1.7.1 - Front panel access ...........................................................................................................................17 1.7.2 - Description of accesses and connectors..........................................................................................18

1.7.2.1 "POWER" access – 3-pin connector................................................................................................................................18 1.7.2.2 "Serial" (PC) access – 9-pin DB connector ....................................................................................................................19 1.7.2.3 "Alarms IN/OUT" access – High density 15-pin DB connector .......................................................................................19 1.7.2.4 "Mgmt" and "Wayside" Ethernet ports............................................................................................................................20 1.7.2.5 Gigabit Ethernet ports "GbE1" to "GbE4".......................................................................................................................21 1.7.2.6 G703 2 Mbit/s access - 44-pin DB connectors ................................................................................................................22

1.7.3 - Cable References for SAGEM-LINK F-H .........................................................................................25 1.7.4 - Module references for SAGEM-LINK F-H ........................................................................................27

1.8 - POWERING UP THE SYSTEM ......................................................................................................................................27 2. COMMISSIONING CONFIGURATION AND TESTS ............................................................................................29

2.1 - INTRODUCTION ........................................................................................................................................................29 2.2 - CONFIGURING EQUIPMENT IP ADDRESSES................................................................................................................29 2.3 - PILOT SOFTWARE AND IP CONNECTIVITY .................................................................................................................34

2.3.1 - Installing the Pilot software...............................................................................................................34 2.3.2 - IP connectivity...................................................................................................................................35 2.3.3 - Starting a Pilot session .....................................................................................................................36

2.4 - LINK PRELIMINARY CONFIGURATION .......................................................................................................................37 2.4.1 - Setting the parameters of each IDU .................................................................................................37 2.4.2 - Antenna alignment............................................................................................................................39

2.5 - TESTS AND MEASUREMENTS REQUIRED....................................................................................................................42 2.5.1 - Frequency Scan................................................................................................................................43 2.5.2 - Receive signal level..........................................................................................................................43 2.5.3 - Giga Ethernet transmission test .......................................................................................................44 2.5.4 - 2 Mbit/s tributary test (optional) ........................................................................................................47 2.5.5 - Wayside test (optional) .....................................................................................................................48 2.5.6 - Alarm relay test (optional).................................................................................................................49

2.5.6.1 Simulating an IDU Alarm ...............................................................................................................................................49 2.5.6.2 Simulating an ODU Alarm..............................................................................................................................................50 2.5.6.3 Simulating a Gigabit Ethernet Alarm ..............................................................................................................................50 2.5.6.4 Simulating a tributary alarm............................................................................................................................................50 2.5.6.5 Simulating an RSL alarm ................................................................................................................................................50 2.5.6.6 Testing an external alarm ................................................................................................................................................50 2.5.6.7 Testing the alarm outputs (relays) ...................................................................................................................................50

2.5.7 - Testing 1+1 configuration (optional) .................................................................................................51 2.5.8 - Quality measurement .......................................................................................................................52 2.5.9 - Recording configuration information.................................................................................................53

Page 5: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 5/134

3. FINAL LINK CONFIGURATION ..............................................................................................................................58 3.1 - ENTERING SITE NAMES .............................................................................................................................................58 3.2 - SETTING THE PILOT DATE AND TIME ........................................................................................................................59 3.3 - CONFIGURING THE GIGABIT ETHERNET ACCESSES...................................................................................................59

3.3.1 - "Configuration / Gigabit Ethernet / Ethernet port configuration / Local or Remote" menu ...............59 3.3.2 - "Configuration / Gigabit Ethernet / Radio channel configuration / Local or Remote" menu.............60 3.3.3 - "Configuration / Gigabit Ethernet / Advanced configuration / QoS configuration / Local or Remote" menu ............................................................................................................................................................61 3.3.4 - "Configuration / Gigabit Ethernet / Advanced configuration / Congestion configuration / Local or Remote" menu .............................................................................................................................................62 3.3.5 - "Configuration / Gigabit Ethernet / Advanced configuration / Security configuration / Mac filtering / Local or Remote" menu ...............................................................................................................................62

3.4 - CONFIGURING 2 MBIT/S ACCESSES...........................................................................................................................63 3.5 - CONFIGURING THE ALARM THRESHOLDS..................................................................................................................65

3.5.1 - BER alarm thresholds.......................................................................................................................65 3.5.2 - RSL alarm threshold.........................................................................................................................65

3.6 - CONFIGURING THE ALARMS .....................................................................................................................................66 3.6.1 - General parameters..........................................................................................................................66 3.6.2 - "IDU" tab ...........................................................................................................................................67 3.6.3 - "Modem" tab .....................................................................................................................................68 3.6.4 - "Radio" tab........................................................................................................................................68 3.6.5 - "Tributaries" tab ................................................................................................................................69 3.6.6 - "Gigabit Ethernet" tab .......................................................................................................................69 3.6.7 - "Fans" tab .........................................................................................................................................70 3.6.8 - Default configuration of the alarm relays..........................................................................................70

3.7 - CONFIGURING THE AUTOMATIC TRANSMIT POWER CONTROL (ATPC) ...................................................................70 3.8 - CONFIGURING THE INTERLEAVER.............................................................................................................................71 3.9 - SPECIFIC CONFIGURATIONS FOR 1+1 SYSTEMS ........................................................................................................72

4. OPERATION – PILOT.................................................................................................................................................73 4.1 - HELP MENU ..............................................................................................................................................................75 4.2 - FILE MENU ...............................................................................................................................................................76

4.2.1 - "File / System Report" menu ............................................................................................................76 4.2.2 - "File / IDU Configuration / Local or Remote / Save" menu...............................................................76 4.2.3 - "File / IDU Configuration / Local or Remote / Load" menu...............................................................76 4.2.4 - "File / Boot Firmware / Local or Remote" menu ...............................................................................77 4.2.5 - "File / IDU Firmware / Local or Remote" menu ................................................................................77 4.2.6 - "File / ODU Firmware / Local or Remote" menu...............................................................................78 4.2.7 - "File / Quit" menu..............................................................................................................................78

4.3 - SESSION MENU .........................................................................................................................................................78 4.4 - ALARMS MENU.........................................................................................................................................................79

4.4.1 - "Alarms / View / Local or Remote" menu..........................................................................................79 4.4.2 - "Alarms / Text Log / Local or Remote" menu ...................................................................................79 4.4.3 - "Alarms /Graphical Log / Local or Remote" menu............................................................................80

4.5 - CONFIGURATION / ALARMS MENU ...........................................................................................................................81 4.6 - CONFIGURATION / MANAGEMENT NETWORK / ETHERNET PORTS AND RADIO CHANNEL / LOCAL OR REMOTE MENU.........................................................................................................................................................................................81

4.6.1 - Description of the Management network..........................................................................................81 4.6.2 - Network configuration.......................................................................................................................84 4.6.3 - Wayside configuration ......................................................................................................................84

4.7 - CONFIGURATION / MANAGEMENT NETWORK /ROUTES / LOCAL OR REMOTE MENU ................................................85 4.8 - CONFIGURATION / GIGABIT ETHERNET MENU ..........................................................................................................86 4.9 - CONFIGURATION / PROTECTION / LOCAL OR REMOTE MENU....................................................................................86 4.10 - CONFIGURATION / ATPC / LOCAL OR REMOTE MENU............................................................................................87 4.11 - CONFIGURATION /E1 TRIBUTARIES / LOCAL OR REMOTE MENU ............................................................................87 4.12 - CONFIGURATION / HARDWARE INVENTORY / LOCAL OR REMOTE MENU ...............................................................87 4.13 - CONFIGURATION / PILOT MENU..............................................................................................................................88 4.14 - CONFIGURATION / RESET TO DEFAULT DATABASE / LOCAL OR REMOTE MENU .....................................................88 4.15 - PERFORMANCE / RSL / LOCAL OR REMOTE MENU .................................................................................................88 4.16 - PERFORMANCE / LINK STATISTICS / LOCAL OR REMOTE MENU .............................................................................89

Page 6: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 6/134 Sagem Communications document. Reproduction and disclosure prohibited

4.17 - PERFORMANCE / GIGABIT ETHERNET / GENERAL ETHERNET STATISTICS / LOCAL OR REMOTE MENU...................90 4.18 - PERFORMANCE / GIGABIT ETHERNET / METERING STATISTICS / LOCAL OR REMOTE MENU ..................................90 4.19 - PERFORMANCE / WAYSIDE / LOCAL OR REMOTE MENU .........................................................................................91 4.20 - PERFORMANCE / CLEAR BER STATS / LOCAL OR REMOTE MENU ..........................................................................91 4.21 - MAINTENANCE / TX/RX FORCING MENU................................................................................................................91 4.22 - MAINTENANCE / LOOPBACKS MENU ......................................................................................................................92 4.23 - MAINTENANCE / FREQUENCY SCAN / CHANNEL 1 OR CHANNEL 2 MENU...............................................................92 4.24 - MAINTENANCE / TRY TO UNMUTE REMOTE / LOCAL OR REMOTE MENU ................................................................93 4.25 - MAINTENANCE / RESTRICTION / LOCAL OR REMOTE MENU ...................................................................................93

5. TROUBLESHOOTING GUIDE ..................................................................................................................................94 5.1 - INTRODUCTION ........................................................................................................................................................94 5.2 - VISUAL INSPECTION .................................................................................................................................................94 5.3 - TROUBLESHOOTING PROCEDURE..............................................................................................................................95

5.3.1 - Describe the symptom......................................................................................................................95 5.3.2 - Isolate the problem ...........................................................................................................................95 5.3.3 - Fix the problem.................................................................................................................................95

5.4 - DESCRIPTION OF IDU FRONT PANEL LEDS ..............................................................................................................95 5.4.1 - Description of IDU LEDs...................................................................................................................96 5.4.2 - Description of the Modem front panel LEDs.....................................................................................96

5.5 - ALARMS MANAGED BY THE PILOT ...........................................................................................................................96 5.5.1 - Alarm summary screen.....................................................................................................................96 5.5.2 - Direct and indirect alarms...............................................................................................................103 5.5.3 - Event log.........................................................................................................................................103

5.6 - TYPICAL SAGEM-LINK F-H PILOT SCREENS IN CASE OF PROBLEM......................................................................103 5.6.1 - No IDU-Pilot software communication............................................................................................103 5.6.2 - No local equipment, no remote equipment.....................................................................................103 5.6.3 - No local radio..................................................................................................................................104 5.6.4 - No remote radio..............................................................................................................................104 5.6.5 - Low RSL .........................................................................................................................................105 5.6.6 - Low transmit power ........................................................................................................................105 5.6.7 - Link established correctly but with some alarms............................................................................106 5.6.8 - Normal link no alarms.....................................................................................................................106

5.7 - REPLACING AN ODU..............................................................................................................................................106 5.8 - REPLACING A MODEM ............................................................................................................................................107 5.9 - REPLACING AN IDU ...............................................................................................................................................107

6. SYSTEM DESCRIPTION ..........................................................................................................................................108 6.1 - INTRODUCTION ......................................................................................................................................................108 6.2 - DESCRIPTION..........................................................................................................................................................108

6.2.1 - System composition .......................................................................................................................108 6.2.2 - IDU version .....................................................................................................................................110 6.2.3 - Modem version ...............................................................................................................................110 6.2.4 - Fan version.....................................................................................................................................110 6.2.5 - ODU Versions.................................................................................................................................111

6.3 - SAGEM-LINK F-H FEATURES ..............................................................................................................................112 6.3.1 - SAGEM-LINK F-H block diagrams .................................................................................................112 6.3.2 - IDU features....................................................................................................................................113 6.3.3 - Modem features..............................................................................................................................113 6.3.4 - ODU features..................................................................................................................................114

6.4 - PROTECTED CONFIGURATIONS ...............................................................................................................................115 6.4.1 - 1+1 hot standby (HSB) ...................................................................................................................115 6.4.2 - 1+1 space diversity.........................................................................................................................115 6.4.3 - 1+1 frequency diversity...................................................................................................................116

Page 7: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 7/134

7. GIGABIT ETHERNET FUNCTION.........................................................................................................................117 7.1 - S_VLAN SERVICES................................................................................................................................................117 7.2 - PORTS ....................................................................................................................................................................117

7.2.1 - Definition.........................................................................................................................................117 7.2.2 - Radio port shaping .........................................................................................................................117 7.2.3 - Jumbo frames.................................................................................................................................117

7.3 - TOPOLOGY .............................................................................................................................................................118 7.4 - CONGESTION..........................................................................................................................................................118

7.4.1 - Eliminating congestion....................................................................................................................118 7.4.2 - Processing congestion ...................................................................................................................118

7.4.2.1 Description ....................................................................................................................................................................118 7.4.2.2 Traffic control ...............................................................................................................................................................118 7.4.2.3 Output queues................................................................................................................................................................118

7.5 - QUALITY OF SERVICE (QOS) ..................................................................................................................................119 APPENDIX 1- SAGEM-LINK F-H SPECIFICATIONS.............................................................................................120

GENERAL CHARACTERISTICS ..........................................................................................................................................120 TRANSMISSION CHARACTERISTICS..................................................................................................................................121 RECEPTION CHARACTERISTICS........................................................................................................................................122 GIGABIT ETHERNET / 2 MBIT/S ACCESS ..........................................................................................................................122 WAYSIDE AND NETWORK MANAGEMENT INTERFACES....................................................................................................122 MECHANICAL CHARACTERISTICS....................................................................................................................................123 POWER CONSUMPTION ....................................................................................................................................................123 ENVIRONMENTAL CHARACTERISTICS..............................................................................................................................123

APPENDIX 2 - GIGABIT ETHERNET ACCESS SPECIFICATIONS.....................................................................124 GIGABIT ETHERNET THROUGHPUT WITHOUT QOS..........................................................................................................124 GIGABIT ETHERNET THROUGHPUT WITH QOS ................................................................................................................125 LATENCY DEPENDING ON THE CONFIGURATION..............................................................................................................126

APPENDIX 3 - SAGEM-LINK F-H REFERENCES...................................................................................................127 LINK COMPOSITION.........................................................................................................................................................127 REFERENCES OF SAGEM-LINK F-H ODUS ..................................................................................................................128

Page 8: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 8/134 Sagem Communications document. Reproduction and disclosure prohibited

FIGURES Figure 1.1 - IDU installation ................................................................................................................................11 Figure 1.2 - ODU SAGEM-LINK F-H with integrated antenna............................................................................13 Figure 1.3 - Polarization setting in 1+0 configuration..........................................................................................13 Figure 1.4 - ODU SAGEM-LINK F-H mounted on pole ......................................................................................14 Figure 1.5 - SAGEM-LINK F-H 1+1 configuration with coupler and integrated antenna....................................15 Figure 1.6 - Polarization setting on 1+1 coupler .................................................................................................15 Figure 1.7 - Front panel of the SAGEM-LINK F-H IDU in 1+0 configuration ......................................................17 Figure 1.8 - Front panel of the SAGEM-LINK F-H IDU in 1+1 configuration ......................................................17 Figure 1.9 - "POWER" connector pinout.............................................................................................................18 Figure 1.10 - "Serial" connector pinout ...............................................................................................................19 Figure 1.11 - Relay output electrical interface ...................................................................................................19 Figure 1.12 - External alarm electrical interface ................................................................................................19 Figure 1.13 - "Alarm IN/OUT" connector pinout ....................................................................................................20 Figure 1.14 - Ethernet port pinout .......................................................................................................................21 Figure 1.15 - TRIB 1-8 connector pinout.............................................................................................................23 Figure 1.16 - TRIB 9-16 connector pinout...........................................................................................................24 Figure 1.17 - Cables for a terminal station..........................................................................................................25 Figure 1.18 - Cables for a relay station...............................................................................................................25 Figure 1.19 - SAGEM-LINK F-H 1+1 IDU ...........................................................................................................27 Figure 1.20 - IDU power supply connector ........................................................................................................28 Figure 2.1 - SAGEM-LINK F-H ODU RSL voltage..............................................................................................40 Figure 2.2 - Antenna alignment...........................................................................................................................40 Figure 2.3 - Main Pilot Screen for a 1+0 configuration .......................................................................................41 Figure 2.4 - Main Pilot Screen for a 1+1 configuration .......................................................................................42 Figure 2.5 - Main local transmitter and receiver active ......................................................................................51 Figure 2.6 - Main local transmitter and local receiver active..............................................................................52 Figure 2.7 - Local standby transmitter and receiver active .................................................................................52 Figure 4.1 - Pilot menu tree structure .................................................................................................................74 Figure 5.1 - IDU front panel LEDs......................................................................................................................95 Figure 5.2 - Alarm screen on the Pilot ...............................................................................................................97 Figure 6.1 - SAGEM-LINK F-H 1+0 terminal ...................................................................................................109 Figure 6.2 - SAGEM-LINK F-H 1+1 Terminal (HSB) .......................................................................................110 Figure 6.3 - Minimum and maximum channel frequencies ..............................................................................111 Figure 6.4 - SAGEM-LINK F-H block diagram (1+0 configuration)..................................................................112 Figure 6.5 - SAGEM-LINK F-H block diagram (1+1 configuration)..................................................................113 Figure 6.6 - 1+1 hot standby configuration ......................................................................................................115 Figure 6.7 - 1+1 space diversity configuration .................................................................................................115 Figure 6.8 - 1+1 frequency diversity configuration with 2 antennas per terminal ............................................116 Figure 6.9 - 1+1 frequency diversity configuration with dual polarized antenna.............................................116

Page 9: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 9/134

TABLES Table 1.1 - Characteristics of the Gigabit Ethernet optical interface ..................................................................21 Table 1.2 - Cable References for SAGEM-LINK F-H .........................................................................................26 Table 1.3 - SFP module references for SAGEM-LINK F-H ................................................................................27 Table 3.1 - Default configuration of the alarm relays ..........................................................................................70 Table 5.1 - Meaning of the Wayside alarm .........................................................................................................98 Table 5.2 - Meaning of radio alarms ...................................................................................................................98 Table 5.3 - Meaning of Fan and Temperature alarms ........................................................................................99 Table 5.4 - Meaning of Modem alarms .............................................................................................................100 Table 5.5 - Meaning of ODU alarms .................................................................................................................101 Table 5.6 - Meaning of Gigabit Ethernet alarms ...............................................................................................102 Table 5.7 - Meaning of E1 Tributary alarms......................................................................................................102 Table 5.8 - Meaning of External alarms............................................................................................................102

Page 10: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 10/134 Sagem Communications document. Reproduction and disclosure prohibited

1. INSTALLATION

1.1 - INTRODUCTION This paragraph explains how to install and set up SAGEM-LINK F-H radio links. The main topics covered are:

• Unpacking the Equipment

• IDU installation

• Antenna installation

• ODU installation

• IDU to ODU coaxial cable installation

• Connecting IDU to external equipment

• Powering up the system

1.2 - UNPACKING THE EQUIPMENT Verify that the items received are compliant with the packing list. If any part of the equipment is damaged, contact SAGEM Communications for repair or replacement instructions. The IDU and ODU are packaged in two separate boxes. In addition, the optional items are packaged in a separate container. The IDU box contains the IDU equipped with one or two modems (one for 1+0 systems, two for 1+1 systems), the power supply cable and a CD-ROM including the user manual and the Pilot software. The ODU box contains the ODU only. Whenever possible, save case and shipping material, in case the equipment has to be returned.

Page 11: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 11/134

1.3 - IDU INSTALLATION

To install the IDU in a 19-inch rack: • Attach the IDU in the 19-inch rack using 6x12 stainless steel hex screws. This attachment grounds

the IDU to the earth.

Figure 1.1 - IDU installation

• An additional grounding is possible by the use of a Faston plug (left side of the IDU). Use a 6 mm2 section yellow/green cable (minimum length required).

Note: When more than one IDU are to be mounted in the rack, it is recommended to keep a gap of 1 unit between two IDUs.

1.4 - ANTENNA INSTALLATION

Three types of antenna are available for SAGEM-LINK F-H radios: • Integrated antenna with SAGEM-LINK F-H mechanical interface (0.3 m, 0.6 m, 0.9 m, 1.2 m

or 1.8 m diameter). The ODU is directly attached on the antenna using latches. In 1+1 configuration, a coupler can be attached directly to the integrated antenna, the ODUs being attached in the same way on the coupler.

• External antenna with standard rectangular waveguide interface, which is connected to the SAGEM-LINK F-H ODU with a flex guide.

• External dual polarized antenna (frequency diversity configuration) connected by flex guides to two ODUs.

Antennas models depend on the frequency bands:

• 6 GHz (6L) → 5.9 - 6.4 GHz • 6 GHz (6H)→ 6.4 - 7.1 GHz • 7 GHz → 7.1 - 7.7 GHz • 8 GHz → 7.7 - 8.5 GHz • 11 GHz → 10.7 - 11.7 GHz • 13 GHz → 12.75 - 13.25 GHz • 15 GHz → 14.4 - 15.35 GHz • 18 GHz → 17.7 - 19.7 GHz • 23 GHz → 21.2 - 23.6 GHz • 26 GHz → 24.5 - 26.5 GHz • 32 GHz → 31.8 - 33.4 GHz • 38 GHz → 37 - 39.5 GHz

Faston socket

Page 12: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 12/134 Sagem Communications document. Reproduction and disclosure prohibited

Alternative antennas to those specified by Sagem Communications may be used, but they must meet the following requirements: • Minimum gain to achieve adequate link margin, • Radiation Pattern Envelope compliant to the network and country regulations • Mechanical characteristics to meet specific site requirements (wind and frost resistance)

Note: With some antennas, a pressurizing system is required. It is essential to observe the manufacturer's recommendations:

installation and connection of a pressurizing system if the antenna is connected to the ODU with a waveguide;

use pressurization windows and seals to protect waveguide connections.

1.4.1 - Antenna mount In most cases, the antenna mounts consist of tubular poles (diameter 88.9 to 114 mm).

If the antenna is installed on towers using another type of structure (e.g., square-section tower), special mounting kits must be used for this support. The following precautions must always be taken:

- Allow enough clearance (±10°) about the alignment axis. Leave also adequate space around the ODU to allow easy mounting/dismantling.

- Make sure that nothing obstructs the link between the two antennas, even partially,

- Install a lightning rod (Franklin) and earthing.

Note: If there is an existing lightning rod, make sure that the ODU installation site is covered by the lightning protection cone.

- Misalignment under extreme weather conditions must not exceed ± 20 min angle in elevation

and azimuth. The antenna mount may be secured in different ways depending on the antenna installation site type and environment:

- Mounting pole secured to the HEA section with back-plates or clips each side of the HRA section,

- Mounting pole secured to a concrete base plate with threaded rods embedded in the base.

- Wall-mounted staff (attached using dowels or back-plates with threaded rods),

- Antenna mount secured directly to a tower tube (diameter 88.9 or 114 mm).

1.4.2 - Antenna Installation

Refer to the antenna manufacturer's instructions.

Page 13: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 13/134

1.5 - ODU INSTALLATION

Depending on the configuration and on the antenna type, there are several ODU mounting possibilities:

1.5.1 - 1+0 Configuration with integrated antenna

The ODU is directly attached to the antenna with 4 latches. It is connected to the IDU by a single coaxial cable terminated with N connectors.

Figure 1.2 - ODU SAGEM-LINK F-H with integrated antenna Setting the polarization: For antennas with a circular waveguide interface (7 GHz, 8 GHz, 32 GHz or 38 GHz), polarization setting depends only on the ODU position. For vertical polarization, make sure that the arrow on the ODU cover is vertical, for horizontal polarization, turn the ODU 90 degrees.

Horizontal polarization Vertical polarization

Figure 1.3 - Polarization setting in 1+0 configuration

Page 14: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 14/134 Sagem Communications document. Reproduction and disclosure prohibited

If the integrated antenna has a rectangular waveguide interface (6 GHz, 11 GHz, 13 GHz, 15 GHz, 18 GHz, 23 GHz or 26 GHz), then the choice of polarization depends on the antenna source position. Note that in this case, the large side of the waveguides, antenna side, and the ODU must coincide. For vertical polarization, the large side of the waveguide must be in horizontal position. ODU side, the arrow at the back of the box must be in vertical position. For horizontal polarization, the large side of the waveguide must be in vertical position and the arrow on the ODU must be in horizontal position.

1.5.2 - 1+0 Configuration with pole mount and standard antenna

For standard antennas (i.e. large diameter), the ODU is mounted on a pole with a specific mounting kit and connected to the antenna with a standard rectangular flex guide. In this case, polarization depends on the antenna source position (vertical polarization is obtained when the large side of the antenna waveguide is horizontal).

Figure 1.4 - ODU SAGEM-LINK F-H mounted on pole

1.5.3 - "Hot standby" 1+1 configuration with coupler and integrated antenna

In this configuration, the coupler is attached on the integrated antenna with four latches. Two ODUs are mounted each side of the coupler with four latches. Depending on the type of coupler, the ODUs are mounted differently. Refer to the instructions marked on the coupler. Each ODU is connected to its modem by a coaxial cable. As in most cases the coupler is not symmetrical, it is important to identify which ODU is connected to the main position, and which ODU is connected to protection (standby) position. The main and standby ODU positions are indicated on the coupler.

Page 15: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 15/134

Whatever the polarization, the coupler is always mounted in the same position (the ODUs must be vertical). The IDU has two modems connected to ODUs operating at the same frequency. The standby transmitter is configured automatically by the software in "Mute" position.

Figure 1.5 - SAGEM-LINK F-H 1+1 configuration with coupler and integrated antenna

Vertical polarization Horizontal polarization

Figure 1.6 - Polarization setting on 1+1 coupler

1.5.4 - 1+1 hot standby configuration with remote mounted coupler and standard antenna

The coupler is attached on the remote mount and connected to the standard antenna by a rectangular flex waveguide. The two ODUs are mounted vertically each side of the coupler, in compliance with the instructions shown on the coupler. Each ODU is connected to its modem with a coaxial cable. Polarization setting is done antenna side.

Page 16: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 16/134 Sagem Communications document. Reproduction and disclosure prohibited

It is also necessary to identify ODU cables (Main or Standby) with labels. The IDU has two modems connected to ODUs operating at the same frequency. The standby transmitter is configured automatically by the software in "Mute" position.

1.5.5 - 1+1 space diversity configuration with 2 antennas

This configuration is similar to "hot standby" except that the ODUs are not coupled to the same antenna: they are located at different positions, each connected to its own antenna. This configuration is possible with integrated or standard antennas. The IDU has two modems connected to ODUs operating at the same frequency. The standby transmitter is configured automatically by the software in "Mute" position.

1.5.6 - 1+1 frequency diversity configuration with remote mounts and dual polarized antenna

In this configuration, each ODU is remote mounted on a pole and connected to an antenna access with a flex guide. It is important to identify the cables of the ODU mounted in vertical polarization (main) and that mounted in horizontal polarization (standby). The IDU has two modems connected to ODUs operating at the two different frequencies. The two transmitters transmit permanently.

1.6 - INSTALLING THE IDU TO ODU COAXIAL CABLE Two types of cable are recommended: RG8/X (1/4") for lengths less than or equal to 80 m, and RG8/U (3/8") for length less than or equal to 230 m. Andrew LDF4-50A cable can be used for lengths up to 600 m. Other cables may be used, but must be compatible as regards outdoor use (resistance to UV), losses, shielding (double or triple braid) and characteristics impedance (50 Ohm, N male straight connectors at each end). Only connectors recommended by the cable manufacturer should be used. These connectors must be assembled in compliance with the manufacturer's recommendations. Since the Modem ODU access is a TNC type connector, an optional RG223/U Type stub cable equipped with a 50 ohm angled male TNC connector at one end and a 50 ohm straight female N connector at the other must be inserted between the cable connecting the ODU and the modem; this cable can be ordered from SAGEM Communications (see Table 1.2 - Cable References for SAGEM-LINK F-H). Self-vulcanizing tape is wound around the connectors to make them water-tight. Note: Cables must be installed in compliance with the national and local regulations of the

installation site. Special precautions are necessary when installing cables to prevent possible damage by lightning (regular grounding).

In 1+1 configuration, it is important to distinguish between the cable connected to the main ODU and that connected to the standby ODU. If the cables are not labelled, it is necessary to perform a resistance check to identify each cable.

Page 17: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 17/134

Disconnect the cable IDU side and short circuit the connector main ODU side (the standby ODU connector being in open circuit). Measure the resistance of the two cables IDU side using a multimeter. The cable to be connected on the main ODU is that with the lower resistance (now identify the cables ODU and IDU side with a label, sticker, etc.). Before reconnecting the IDU cables, disconnect the short circuit ODU side. Clean the connectors if necessary and connect the cables on each ODU. Cable Grounding Good lightning protection is provided by grounding the antenna cable at several points. A cable grounding kit is available on option. The number of grounding points required mainly depends on the cable length. Good protection is achieved with:

• A grounding kit on the cable as close as possible to the ODU • A grounding kit on the cable at the building entrance • A grounding kit on the cable at the bottom of the pylon • A grounding kit every 50 meters

1.7 - CONNECTING THE IDU TO EXTERNAL EQUIPMENT

1.7.1 - Front panel access

All IDU accesses are located on the front panel:

Figure 1.7 - Front panel of the SAGEM-LINK F-H IDU in 1+0 configuration

Figure 1.8 - Front panel of the SAGEM-LINK F-H IDU in 1+1 configuration

Standby modem

Main modem

On/off switch

Green Power LED To ODU2

To ODU1

PC serial port

-48 V input

Ethernet management ports

2Mbit/s optional accesses Trib 1-8 Trib 9-16

Giga Ethernet access Wayside channel

Fans

Interface connector for 2Mbit/s extension

Alarms Inputs/Outputs

Page 18: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 18/134 Sagem Communications document. Reproduction and disclosure prohibited

• "POWER" access – 3-pin connector: -48 V power supply input (voltage between -39 VDC and -59 VDC),

• "Serial" (PC) access – 9-pin DB connector: serial management access for connection to a PC. This access is used to consult or change the IP address of the Ethernet Mgmt ports and the equipment virtual IP address.

• "Alarms IN/OUT" access – high density 15-pin DB connector: includes the 5 external alarm inputs and the 3 programmable relay outputs.

• Four Ethernet ports – RJ 45 connectors:

• 1 "Protect" port reserved for future external IDU protection.

• 1 "Wayside" 10/100BaseT port: auxiliary channel

• 2 x 10/100BaseT ports dedicated to network management "Mgmt1" and "Mgmt2"

• Four Gigabit Ethernet ports "GbE1", "GbE2", "GbE3", "GbE4»: these ports receive optical SFP (LC/PC connector) or electrical (RJ45 connector) modules. These modules can be 1000BaseSX (multimode optical), 1000BaseLX (single-mode optical) or 10/100/1000BaseT (electrical) Each Gigabit Ethernet port is configured independently: one port can be configured with an electrical module, another with an optical module. Note that the remote terminal ports are configured independently from those of the local terminal. Note: at release R1, only the two Gigabit Ethernet ports on the left will be used.

• 2Mbit/s optional ports "TRIB 1-8" and "TRIB 9-16" G703 – 44-pin DB connector: configurable by software either in 75Ω coaxial mode or in 120Ω balanced mode. Configuration can be carried out by connector.

• 1 or 2 "ODU" ports –TNC connector: connection with the ODU.

• One ground connection (male "Faston" connector).

1.7.2 - Description of accesses and connectors

1.7.2.1 "POWER" access – 3-pin connector Power connection is via a WAGO 3-pin male connector with the following pinout.

Pin Signal name Meaning 1 N48V -48 V DC 2 OB 0 Volt (also connected to GND) 3 GND Ground

Figure 1.9 - "POWER" connector pinout

-48 V 0 V Ground

3 2 1

Page 19: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 19/134

1.7.2.2 "Serial" (PC) access – 9-pin DB connector The connector pinout is as follows:

1 5

9 6

Output

2 3

Input

Ground

Figure 1.10 - "Serial" connector pinout

1.7.2.3 "Alarms IN/OUT" access – High density 15-pin DB connector This connector allows access to: • 3 configurable relay outputs: these alarms are managed by the Pilot software. The electrical

interface for each relay is given below:

Normally Open

Normally Closed

Common

Figure 1.11 - Relay output electrical interface

The 3 relay contacts are available. These contacts can be assigned either to internal alarms of the equipment, external alarms, or a combination of the two. The alarm state corresponds to the relay in standby position (normally closed).

• 5 external alarms (inputs)

EXT IN 10 k Ω

Photocoupler

-48V

GND

5 external inputs

SAGEM-LINK HC

Open: no alarm if configured in normal position (N) Closed: alarm if confifgured in normal position (N) Open: alarm if configured in invert position (I) Closed: No alarm if configured in invert position (I)

Figure 1.12 - External alarm electrical interface

Page 20: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 20/134 Sagem Communications document. Reproduction and disclosure prohibited

The alarm connector pinout is given below.

1

10 6

5

15 11

Pin Signal Description 1 EXT IN1 External alarm input #1

2 EXT IN2 External alarm input #2 3 EXT IN3 External alarm input #3 4 EXT IN4 External alarm input #4 5 EXT IN5 External alarm input #5 6 RELAY 3C Relay #3 Common 7 RELAY 3NO Relay #3 Normally Open 8 RELAY 2NC Relay #2 Normally Closed 9 GND Ground

10 RELAY 1NC Relay #1 Normally Closed 11 RELAY 3NC Relay #3 Normally Closed 12 RELAY 2C Relay #2 Common 13 RELAY 2NO Relay #2 Normally Open 14 RELAY 1C Relay #1 Common 15 RELAY 1NO Relay #1 Normally Open

Figure 1.13 - "Alarm IN/OUT" connector pinout

1.7.2.4 "Mgmt" and "Wayside" Ethernet ports

RJ 45 connectors are used for Ethernet type signals. The ports "Mgmt1" and "Mgmt2" are part of an internal hub, and can be connected to the Ethernet port of the PC, to another IDU or to an SNMP manager. The 3 connectors have the same pinout (Ethernet standard):

1 8

Page 21: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 21/134

Pin I/O Name Meaning 1 I RXETHP Receive Ethernet + wire

2 I RXETHN Receive Ethernet - wire

3 O TXETHP Transmit Ethernet + wire

4 - NC Not Connected

5 - NC Not Connected

6 O TXETHN Transmit Ethernet - wire

7 - NC Not Connected

8 - NC Not Connected

Figure 1.14 - Ethernet port pinout Each connector has two LEDs: - a green LED on the left: indicates Ethernet signal activity at the input. If this LED is not lit permanently, it means that the cable is not correctly connected to the port, or that the equipment connected to the SAGEM-LINK F-H does not work. - an orange LED on the right: indicates a 100BaseT transmission (10BaseT when the LED is off)

1.7.2.5 Gigabit Ethernet ports "GbE1" to "GbE4"

The IDU has four Gigabit Ethernet interfaces on the front panel; only the two ports on the left are used at release R1.

These ports can receive:

- SFP optical modules (Small Form Factor Pluggable Transceiver MultiSource Agreement 14 Sept 2000).

Interfaces SX LX

Interface Multimode Single-mode

Standard IEEE 802.3z

IEEE 802.3z

Wavelength 770 - 860 nm 1270 – 1355 nm

Speed 1250 Mbit/s ±100 ppm

1250 Mbit/s ±100 ppm

Transmitted power – 10 µm fibre – 50 µm fibre – 62.5 µm fibre

-

-9.5 dBm min -9.5 dBm min

-11 dBm min

-11.5 dBm min -11.5 dBm min

Sensitivity at 10-10 -17 dBm -19 dBm

Max. permitted power 0 dBm -3 dBm

Typical range – 10 µm fibre – 50 µm fibre – 62.5 µm fibre

-

500 m min 220 m min

5000 m min 550 m min 550 m min

Connector LC/PC LC/PC

Table 1.1 - Characteristics of the Gigabit Ethernet optical interface

Page 22: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 22/134 Sagem Communications document. Reproduction and disclosure prohibited

- SFP electrical modules with the following characteristics:

Speed 10, 100, or 1000 Mbit/s

Standard IEEE 802.3

Maximum cable attenuation 100 m UTP or STP Category 5 Gigabit Ethernet compatible

Connector RJ45

A "GbE Lnk/Act" LED corresponds to each port: • LED off: link down • Green LED lit permanently: link up • Green LED flashing: traffic indicator, flashes for each GE frame • Orange LED lit: collision

1.7.2.6 G703 2 Mbit/s access - 44-pin DB connectors The sixteen 2 Mbit/s accesses are available on the two 44-pin DB connectors. These interfaces are designed to operate in 120 ohm balanced or 75 ohm unbalanced. To operate in 75 ohm, the signals corresponding to the negative polarities (- wire) are connected to the ground by the connector of the cable. The pinout of the 44-pin DB connectors is given below (view of the IDU front panel)

1

30 16

15

313144

Page 23: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 23/134

Pin No. Channel Name Meaning 16 GND Ground 31 TRIB_IN_01N Tributary input No. 1 negative polarity 1 TRIB_IN_01P Tributary input No. 1 positive polarity 17 TRIB_OUT_01N Tributary output No. 1 negative polarity 32

1

TRIB_OUT_01P Tributary output No. 1 positive polarity 2 TRIB_IN_02N Tributary input No. 2 negative polarity 18 TRIB_IN_02P Tributary input No. 2 positive polarity 33 TRIB_OUT_02N Tributary output No. 2 negative polarity 3

2

TRIB_OUT_02P Tributary output No. 2 positive polarity 19 TRIB_IN_03N Tributary input No. 3 negative polarity 34 TRIB_IN_03P Tributary input No. 3 positive polarity 4 TRIB_OUT_03N Tributary output No. 3 negative polarity 20

3

TRIB_OUT_03P Tributary output No. 3 positive polarity 35 TRIB_IN_04N Tributary input No. 4 negative polarity 5 TRIB_IN_04P Tributary input No. 4 positive polarity 21 TRIB_OUT_04N Tributary output No. 4 negative polarity 36

4

TRIB_OUT_04P Tributary output No. 4 positive polarity 6 TRIB_IN_05N Tributary input No. 5 negative polarity 22 TRIB_IN_05P Tributary input No. 5 positive polarity 37 TRIB_OUT_05N Tributary output No. 5 negative polarity 7

5

TRIB_OUT_05P Tributary output No. 5 positive polarity 23 TRIB_IN_06N Tributary input No. 6 negative polarity 38 TRIB_IN_06P Tributary input No. 6 positive polarity 8 TRIB_OUT_06N Tributary output No. 6 negative polarity 24

6

TRIB_OUT_06P Tributary output No. 6 positive polarity 39 TRIB_IN_07N Tributary input No. 7 negative polarity 9 TRIB_IN_07P Tributary input No. 7 positive polarity 25 TRIB_OUT_07N Tributary output No. 7 negative polarity 40

7

TRIB_OUT_07P Tributary output No. 7 positive polarity 10 TRIB_IN_08N Tributary input No. 8 negative polarity 26 TRIB_IN_08P Tributary input No. 8 positive polarity 41 TRIB_OUT_08N Tributary output No. 8 negative polarity 11

8

TRIB_OUT_08P Tributary output No. 8 positive polarity 27 GND Ground 42 GND Ground 12 GND Ground 28

GND Ground 43 GND Ground 13 GND Ground 29 GND Ground 44 GND Ground 14 GND Ground 30 GND Ground 15 GND Ground

Figure 1.15 - TRIB 1-8 connector pinout

Page 24: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 24/134 Sagem Communications document. Reproduction and disclosure prohibited

Pin No. Channel Name Meaning 16 GND Ground 31 TRIB_IN_09N Tributary input No. 9 negative polarity 1 TRIB_IN_09P Tributary input No. 9 positive polarity 17 TRIB_OUT_09N Tributary output No. 9 negative polarity 32

9

TRIB_OUT_09P Tributary output No. 9 positive polarity 2 TRIB_IN_10N Tributary input No. 10 negative polarity 18 TRIB_IN_10P Tributary input No. 10 positive polarity 33 TRIB_OUT_10N Tributary output No. 10 negative polarity 3

10

TRIB_OUT_10P Tributary output No. 10 positive polarity 19 TRIB_IN_11N Tributary input No. 11 negative polarity 34 TRIB_IN_11P Tributary input No. 11 positive polarity 4 TRIB_OUT_11N Tributary output No. 11 negative polarity 20

11

TRIB_OUT_11P Tributary output No. 11 positive polarity 35 TRIB_IN_12N Tributary input No. 12 negative polarity 5 TRIB_IN_12P Tributary input No. 12 positive polarity 21 TRIB_OUT_12N Tributary output No. 12 negative polarity 36

12

TRIB_OUT_12P Tributary output No. 12 positive polarity 6 TRIB_IN_13N Tributary input No. 13 negative polarity 22 TRIB_IN_13P Tributary input No. 13 positive polarity 37 TRIB_OUT_13N Tributary output No. 13 negative polarity 7

13

TRIB_OUT_13P Tributary output No. 13 positive polarity 23 TRIB_IN_14N Tributary input No. 14 negative polarity 38 TRIB_IN_14P Tributary input No. 14 positive polarity 8 TRIB_OUT_14N Tributary output No. 14 negative polarity 24

14

TRIB_OUT_14P Tributary output No. 14 positive polarity 39 TRIB_IN_15N

Tributary input No. 15 negative polarity

9 TRIB_IN_15P Tributary input No. 15 positive polarity 25 TRIB_OUT_15N Tributary output No. 15 negative polarity 40

15

TRIB_OUT_15P Tributary output No. 15 positive polarity 10 TRIB_IN_16N Tributary input No. 16 negative polarity 26 TRIB_IN_16P Tributary input No. 16 positive polarity 41 TRIB_OUT_16N Tributary output No. 16 negative polarity 11

16

TRIB_OUT_16P Tributary output No. 16 positive polarity 27 GND Ground 42 GND Ground 12 GND Ground 28 GND Ground 43 GND Ground 13 GND Ground 29 GND Ground 44 GND Ground 14 GND Ground 30 GND Ground 15 GND Ground

Figure 1.16 - TRIB 9-16 connector pinout

Page 25: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 25/134

1.7.3 - Cable References for SAGEM-LINK F-H The cables which may be connected to the IDU front panel are listed below:

Straight or crossed RJ45 Ethernet cables (3 or 4)

Vers PC

To ODU

IDU – ODU cable (7)

2 Mbit/s cable (Balanced or unbalanced) (12 to 17)

To -48 V power supply

2

1

To management network or other equipment management access

To distribution panel

To distribution panel

6

Optical fiber (8 to 11) or Ethernet cable (5)

To customer Ethernet

To auxiliary Ethernet

Figure 1.17 - Cables for a terminal station

A relay station consists of two terminals connected "back to back". Typical wiring of this configuration is given below:

Ethernet crossed or straight cables

182 Mbit/s channel transfer

Optical fiber or Giga Ethernet cable

Figure 1.18 - Cables for a relay station

Page 26: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 26/134 Sagem Communications document. Reproduction and disclosure prohibited

Figure No. Drawing No. Designation Length Sagem P/N

2.5 m 252885333 1 3000277080 - Power cable 5 m 252829314 12 m 252885346 25 m 252885354

2 55050156EA - 9-pin sub-D serial cable (PC) 1.5 m 55670223 3 m 55670224

3 - Crossed ETHERNET cable 1.5 m 55671323 (NMI/NMI transfer or management) 3 m 55671324

4 - ETHERNET straight cable 1.5 m 55671321 (NMI/NMI transfer or management) 3 m 55671322 2.5 m

5 - GIGA ETHERNET straight cable 5 m Off-the-shelf (for electrical SFP module) 12 m cable 25 m 2.5 m 252867400

6 3000279379 - Alarm cable to distribution panel 5 m 252577720 (DB15HD) 12 m 252867413 25 m 252577738

7 3000281884 - IDU-ODU cable TNC angled male/N straight female 1 m 252890368 251559356EA 2.5 m 251559377

8 - Singe-mode optical jumper 5 m 251559504 LC-PC/LC-PC 10 m 251559517 20 m 251559567 251454275EA 2.5 m 251454262

9 - Singe-mode optical jumper 5 m 251454283 LC-PC/SC-PC 10 m 251454296 20 m 251454410 251615886EA 2.5 m 251616049

10 - Multimode optical jumper 5 m 251616060 LC-PC/LC-PC 10 m 251616078 20 m 251616099 252064893EA 2.5 m 252064934

11 - Multimode optical jumper 5 m 252064947 LC-PC/SC-PC 10 m 252064955 20 m 252064989 2.5 m 252867083

12 3000279375 -Half 2 Mbit/s tributary120 Ω In/Out cable 5 m 252867096 12 m 252867306 25 m 252867314 2.5 m 252867327

13 3000279376 - 2 Mbit/s tributary 75 Ω In/Out cable 5 m 252867335 DB44HD – BNC-F 12 m 252867348 25 m 252867356 2.5 m 252867369

14 3000279377 - 2 Mbit/s tributary 75 Ω In/Out cable 5 m 252867377 DB44HD – BNC-M 12 m 252867380 25 m 252867398 2.5 m 253051829

15 3000301874 - 2 Mbit/s tributary 75 Ω In/Out cable 5 m 253021238 DB44-1,6/5,6 6F-5M 12 m 253021832 25 m 253051840 2.5 m 253051853

16 3000301875 - 2 Mbit/s tributary 75 Ω In/Out cable 5 m 253021241 DB44-1,6/5,6 6M-5M 12 m 253021861 25 m 253051874 2.5 m 253051882

17 3000301877 - 2 Mbit/s tributary 75 Ω In/Out cable 5 m 253021262 DB44 LIBRE-5M 12 m 253021902 25 m 253051915

18 3000279382 - Crossed 2 Mbit/s transfer cable 2.5 m 252867877

Table 1.2 - Cable References for SAGEM-LINK F-H

Page 27: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 27/134

1.7.4 - Module references for SAGEM-LINK F-H

Designation Sagem P/N

SFP Module GE SX 253 108 813

SFP Module GE LX 253 108 826

GE Electrical SFP Module (10/100/1000BaseT) 253 108 834

Table 1.3 - SFP module references for SAGEM-LINK F-H

1.8 - POWERING UP THE SYSTEM

Before powering up the terminal, check that:

• the equipment has not been damaged during installation • the equipment has been assembled correctly • in 1+1 each modem is connected to the corresponding ODU • the antenna polarization is correct • the IDUs, ODUs and connecting cables have been grounded

Figure 1.19 - SAGEM-LINK F-H 1+1 IDU

• the power supply voltage is within the range: -39 V to -59 V (-48 V nominal). Measure the voltage (polarity and amplitude) on the cable plug before plugging it in the IDU. Only negative DC voltage must be used. The power supply connector pinout is given below.

Standby modem

Main modem

On/Off switch

Green Power LED To ODU2

To ODU1 DC Power ln Fans

Page 28: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 28/134 Sagem Communications document. Reproduction and disclosure prohibited

-48VDC

Ground (0 VDC)

Ground

POWER ALARMS IN/OUT PRO1

Serial Trib exte

Figure 1.20 - IDU power supply connector

After checking, plug the DC connector into the IDU. If the terminal is a 1+0 system, switch on the terminal by setting the switch on the modem to ON. If the terminal is a 1+1 system, set the switch on the second modem to ON as well.

The green "Power" LED(s) on the front panel(s) of the modem(s) should be lit.

Measure voltage at the input of each terminal and record the values on the Commissioning Form at the end of paragraph 2.

Page 29: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 29/134

2. COMMISSIONING CONFIGURATION AND TESTS

2.1 - INTRODUCTION

This paragraph describes a preliminary configuration of a SAGEM-LINK F-H, its commissioning and how to verify correct operation after installation. The equipment is commissioned and operated from a PC equipped with VT100 emulation and the Pilot Software.

Configuration required The minimum configuration proposed for the operating PC is as follows:

• OS: Windows XP or Windows Vista

• Pentium 4 or equivalent, frequency: 1 GHz minimum

• RAM: 256 Mbytes (2 Gbytes for Vista)

• 50 Mbytes available on hard disk

• CD-ROM drive

• 10/100BaseT Ethernet port

• Serial port (or USB port + external USB/series adapter)

• SVGA screen, minimum resolution 600 x 800 (minimum 16 colours)

• Windows hyperterminal

• Pilot software

2.2 - CONFIGURING EQUIPMENT IP ADDRESSES Connect the IDU serial port to a serial port on the PC with an RS-232 cable. Run Windows HyperTerminal: "Start/Programs/Accessories/Communications/HyperTerminal". Enter a name in the window which is displayed (e.g. SAGEM-LINK F-H), choose an icon for the connection then validate. In the next window choose the PC "COM" port which is connected to the equipment then validate. In the next window, set the following parameters:

• Bits per second: 19200 • Data bits: 8 • Parity: none • Stop bits: 1 • Flow control: none

Validate the settings and save the connection (Save command in the application File menu). The next you run Hyperterminal, simply choose the connection icon to connect to the equipment. Note: By default, the password is empty on first commissioning.

Page 30: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 30/134 Sagem Communications document. Reproduction and disclosure prohibited

Validate, the following window appears:

To select a command, type the command number in the text zone "Choice ?" and press "ENTER" to validate.

Choice "1": Configuration of the equipment IP address.

The default IP address is 192.168.001.002. Enter the required IP address, keeping in mind that it must be different from that of the other equipment addresses and must be defined in a subnet different from that of the Ethernet interface. The IP address of the remote equipment will belong to the same network. Example: if the IP address of the local equipment is 192.168.113.141, that of the remote equipment will be 192.168.113.xxx with xxx not equal to 141.

Page 31: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 31/134

You are prompted to reboot the equipment. You can reboot later, without affecting the traffic, after entering the settings. Error message "Equipment address is mandatory": you must enter the equipment address

Choice "2": default gateway configuration

The default Gateway IP address is 000.000.000.000. You are prompted to reboot the equipment. You can reboot later, without affecting the traffic, after entering the settings.

Choice "3": Ethernet interface configuration.

The Ethernet interface characteristics are displayed and can be modified: "Interface State": use of the interface: 0 (Interface off) or 1 (Interface on). "IP Address" "Subnet mask" "Route Protocol": 0 (None), 1 (RIP) or 2 (OSPF)

Page 32: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 32/134 Sagem Communications document. Reproduction and disclosure prohibited

The IP address of the Ethernet interface for the equipment connected to the management PC must belong to the same network and have the same subnet mask as the PC IP address. The IP address of the Ethernet interface for the remote equipment must belong to a different network. Example: management equipment address: 135.010.115.015 with a subnet mask of

255.255.255.0 The PC address must be 135.010.115.xxx with xxx not equal to 0, 255 or 015. The address of the remote equipment must belong to another network, e.g. 10.142.113.150.

These management Ethernet interfaces are available on the equipment accesses "Mgmt1" and "Mgmt2".

You are prompted to reboot the equipment. You can reboot later, without affecting the traffic, after entering the settings.

Choice "4": REBOOT the equipment. This command reboots the application immediately, restarting with the settings already stored in the equipment. Reboot takes place without affecting the traffic.

Choice "5": Logout Setting finished, this command closes the current session. The session is closed automatically after several minutes with no activity (delay configurable from the manager).

Choice "6": Ping.

"IP Address": choice of IP address of the equipment you want to reach. Return delay in ms. NOTE: The Ping command is used to check the accessibility and return path from the remote equipment, testing both the interface address and the equipment address. If the address of the port sending the Ping command is different from the equipment address, two commands are transmitted.

Page 33: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 33/134

Choice "7": Trace route.

"IP Address": choice of IP address of the equipment you want to reach. The screen displays the management routes already defined with their characteristics:

Hops: 1, 2, 3… Path to move from one machine to another.

IP address: IP address of the recipient (equipment or subnet).

Delay (ms): return time.

Unit. size: Maximum size of the IP packet that can reach the remote equipment.

Choice "8": Factory settings This command is used to restore the default factory settings. Note: this command is only available from release R1.2 These settings will also be applied on the remote equipment, making sure that: - the IP address of the remote equipment is in the same network as that of the local equipment (not mandatory but recommended) - the IP address of the Ethernet interface for the remote equipment does not belong to the same network as that of the local equipment.

321

Page 34: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 34/134 Sagem Communications document. Reproduction and disclosure prohibited

The principle of equipment IP addressing is described in paragraph 4.6.1 -. Depending on the software release, the routing tables may be static (R1.1) or dynamic (R1.2 and higher). In this case, the RIP and OSPF protocols can be implemented in order to simplify network management configuration.

2.3 - PILOT SOFTWARE AND IP CONNECTIVITY

2.3.1 - Installing the Pilot software The Pilot allows the user to:

• View local and remote terminal configurations

• Set and change parameters on local and remote terminals

• Monitor RSL, BER and alarms

• Download and activate a new software version

• Perform installation and maintenance operations

• Configure the network management interface Insert the Pilot software CD-ROM into the drive. The installation software runs automatically if the drive has been configured in "Autorun" mode. Otherwise, run Windows explorer and double click on "setup.exe".

Once the software is installed, double click on the Pilot icon The following window appears:

The Pilot software is specific to this version of SAGEM-LINK and is not compatible with the previous versions.

Page 35: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 35/134

2.3.2 - IP connectivity Connect an RJ45 Ethernet crossed cable between access "Mgmt1" or "Mgmt2" of the local IDU and the management network. Before starting a Pilot session, check the connectivity between the PC and the local IDU. Check that the IP address of the management PC belongs to the same network as that of the local IDU Ethernet interface, then check the connectivity with a ping of the IDU Ethernet address from the Windows DOS command prompt.

Declare the route to reach the local IDU equipment IP address, then check the connectivity by pinging this address.

Page 36: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 36/134 Sagem Communications document. Reproduction and disclosure prohibited

2.3.3 - Starting a Pilot session

After checking the connectivity, start a Pilot session from the Session/Open session menu The local IDU address is entered in the following window

Click on Add to enter the local IDU address

Click on OK

Page 37: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM- Sagem Communications document. Reprodu

Double click on the IDU address to start the Pilot session; by default, the main Pilot screen is displayed in "View Only" mode.

Click on the "Login" button to enter the default pas

2.4 - LINK PRELIMINARY CONFIGURATION

2.4.1 - Setting the parameters of each

The preliminary configuration of each IDU musthe link is established, virtually all the paramete The parameters of the local and remote terminIn order of priority, the first essential parameteIDU:

• Channel transmit frequency

• Modulation type, radio channel and capa

• Link ID code

• Transmission power; the Automatic Traat this stage ("OFF" position on the Pilot

Note: When powering up for the first time (factin order to avoid transmitting signals at a frequ

The transmitter should be kept in mute positioare properly configured.

When the link is not established, the Pilot screthe screen (see below).

Click here to log in

View Only: read only mode

LINK F-H Installation and Operation Manual – 253 129 101-01 ction and disclosure prohibited Page 37/134

sword: "2345" for a "Super User" level.

IDU

t be carried out separately at each end of the link. Once rs can be checked from the local terminal.

als must be compatible. rs to configure before establishing the link are for each

city

nsmit Power Control (ATPC) function must be inhibited screen)

ory output setting), the transmitter is in "MUTE" position, ency which could disturb neighbouring links.

n until the transmit frequency, modulation and capacity

en indicates "NO REMOTE RADIO" on the right side of

Page 38: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101Page 38/134 Sagem Communications document.

This screen will display the local terminal parameterparameters on the right when the link is established.

The radio channel, modulation, capacity, Ethernet bthe top of the screen. The confirm/cancel modificatioor "Cancel".

The IDU part of the screen is used to define the sdisplay the bit error rate (BER) for a given counting p

The Channel 1 part indicates the received signal lethe transmit frequency and transmit power values, A

The equipment LEDs and the 3 programmable raddition, the "Shelf view" button is used to display th

If you are logged on as a "Super User", you can chEach button provides access to a specific parameter

With the transmitter still in "Mute" and the ATPC "OF

• Channel transmit frequency Move the cursor along the Tx Freq rule validate by clicking on "Confirm" in the top tooUse the arrows to change the frequency in stechanges the frequency in steps of 7 MHz.

• Modulation, radio channel and capacity pa Double click on the top bar

displayed

s

IDU Equipment IP addres

-01 Reproduction and disclosure prohibited

s on the left of the screen and the remote terminal

andwidth and interleaver status are displayed at n request is also displayed in this bar: "Confirm"

ite name, configuration type, link ID code and to eriod (1 min, 15 min or 24 h).

vel and the reception BER; it is used to configure TPC activation and Mute function.

elays status are also displayed on the Pilot. In e front panel of the equipment managed.

ange the terminal configuration with the buttons. . Note that only one change at a time is allowed.

F", configure the following parameters:

, or click on the left or right button, then lbar. ps of 250 kHz. Moving the cursor in the middle

rameters

, the following screen is

Page 39: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 39/134

Choose the parameters according to the choices available for the link (following table) then validate with "Apply".

Modulation Radio channel E1 optional

128 QAM 28 MHz (rate150 Mbit/s)

56 MHz (rate 300 Mbit/s)

0, 2, 4, 8 or 16 E1

0, 4, 8 or 16 E1

16 QAM 28 MHz (rate 70 Mbit/s)

56 MHz (rate 150 Mbit/s)

0, 2, 4, 8 or 16 E1

0, 2, 4, 8 or 16 E1

QPSK 28 MHz (rate 35 Mbit/s)

56 MHz (rate 70 Mbit/s)

0, 2, 4, 8 or 16 E1

0, 2, 4, 8 or 16 E1

The "Interleaver" configuration is described in § 3.8 -.

• Link ID The link ID code is used to avoid demodulating data from another neighbouring link using the same frequency which could disturb the receiver. Link ID Codes of the local and remote terminals must be the same. This code consists of a number from 1 to 255 chosen by the customer.

• Transmit power The transmitter's "Mute" position is set to "OFF". Adjust the transmit power value as planned in the design calculation, keeping ATPC "OFF". Move the cursor along the Tx Power rule , or click on the left or right button, then validate. Use the arrows to change the power in steps of 0.5 dB. Moving the cursor in the middle changes the power in steps of 2.5 dB.

Important: To avoid saturating the transmitter, the Pilot software automatically prevents power values greater than the maximum allowed for the current modulation. Refer to the values in APPENDIX 1 § Transmission characteristics .

The local terminal is now correctly configured. Repeat the procedure for the remote terminal in order to establish the link.

2.4.2 - Antenna alignment

Antenna alignment is performed with both terminals operating, in normal weather conditions. The received signal level (RSL) can be checked using the voltage available on the ODU BNC connector. A typical curve of RSL voltage against RSL at ODU input is given below. The RSL voltage is directly proportional to the RSL expressed in dBm.

Page 40: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 40/134 Sagem Communications document. Reproduction and disclosure prohibited

-90 dBm

1 V

2 V

3 V

4 V

5 V

RSL voltage

RSL (ODU input)

-80 dBm -70 dBm -60 dBm -50 dBm -40 dBm -30 dBm -20 dBm

0.5 V

4.5 V

Figure 2.1 - SAGEM-LINK F-H ODU RSL voltage Note: RSL is measured at ODU antenna port. For 1+1 configurations involving a coupler, the coupler losses must be taken into account to determine the RSL at antenna access. Optimum alignment is achieved when main antenna lobe is aligned with the remote antenna. During alignment, it is important to distinguish between the main lobe and the side lobes by rotating the antenna around the maximum RSL value. Note that there is around 25 dB difference between side lobes and main lobes (i.e. about 1.5 V on the RSL voltage).

Good alignment

Bad alignment

Figure 2.2 - Antenna alignment

Page 41: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 41/134

The expected RSL was determined during the link budget calculation. This level depends on the power of the remote terminal, the frequency, the antennas gain and the hop length. Antenna alignment is carried out on each antenna using the following procedure: 1- Check that the remote terminal transmitter is on, with the planned parameters (frequency,

power, speed, modulation). Check that the ATCP is off and that the remote terminal power is such that the RSL does not exceed –20 dBm.

2- Remove the cap on the ODU BNC connector and connect a voltmeter.

3- Slowly rotate the antenna in the azimuth direction (horizontal) and find the maximum voltage. If the voltage is around 4.5 V, reduce the remote transmit power to avoid saturation.

4- Slowly rotate the antenna in the elevation direction (vertical) and find the maximum voltage. Record the measured voltage.

5- When the maximum voltage has been found, tighten all the bolts. Check that the voltage has not changed after tightening. Replace the protective cap on the BNC connector.

6- Compare the RSL obtained with the expected RSL. If the difference between the two values exceeds 5 dB, readjust antenna alignment and polarization setting and check that there are no obstacles on the radio path.

In principle, if the parameters have been entered correctly and if the antennas have been aligned correctly, the link should be established (no screen with "NO REMOTE RADIO" message) and the main Pilot screen should display the remote terminal parameters. In 1+0 and 1+1 configuration, the typical screens are as follows:

Receive signal levels should be similar on both ends of the link (same transmit power).

Figure 2.3 - Main Pilot Screen for a 1+0 configuration

Note: If the parameters of the two terminals are correct, and if the main Pilot screen displays "NO REMOTE RADIO", the antennas will probably have to be realigned.

Page 42: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 42/134 Sagem Communications document. Reproduction and disclosure prohibited

Figure 2.4 - Main Pilot Screen for a 1+1 configuration

Note: There may still be some alarms at this stage.

In case of "GE" or "tributary" alarm, check the access configuration and connections.

If there are other alarms, or if the link does not work, refer to the troubleshooting paragraph (§ 5 in this manual)

Note any discrepancies in the Commissioning Form at the end of paragraph 2.

2.5 - TESTS AND MEASUREMENTS REQUIRED After installing and setting the link, check correct operation by performing the following tests and measurements:

• Frequency Scan at ODU input • Received Signal Level • Gigabit Ethernet transmission test • 2 Mbit/s channel test (optional) • Wayside access test (optional) • Alarm In/Out test (optional) • 1+1 switching check (optional) • BER measurement

Measurement equipment required:

• Gigabit Ethernet tester • 2 Mbit/s bit error rate analyzer (optional) • Digital multimeter

A SAGEM-LINK F-H Commissioning Form is provided at the end of paragraph 2 in order to record the results of the tests carried out together with any remarks made during installation and commissioning.

Page 43: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 43/134

2.5.1 - Frequency Scan

The Pilot software can be used to take an automatic measurement of the spectrum around the receive frequency without the need for external instruments. The measurement must be taken locally, successively at each end of the link. Measurement is carried out with the local transmitter off (the Pilot software automatically sets the local transmitter to "mute", to avoid sending signals which could disturb other receivers. After acquisition, the spectrum is displayed graphically. This measurement reveals the presence of any interferers. A record of this measurement is stored in the IDU flash memory and can be consulted afterwards using the Pilot or via the network management. In order to check interferer level at the received frequency, the remote transmitter must be switched off during the test. The "Frequency scan" procedure is described in § 4.23 - Note in the commissioning form the presence of any interferers at the received frequency as well as on the adjacent channels (first adjacent and second adjacent). Important: do not run a frequency scan from a remote site

2.5.2 - Receive signal level Under normal weather conditions, the receive signal level depends on the following parameters:

• Remote Transmit Power (tolerance: ± 2 dB)

• Local and remote antenna gains (tolerance: ± 1 dB per antenna)

• Free space path attenuation depending on hop length and frequency

• Coupling and connection losses for a 1+1 system Compare the actual received signal level displayed on the main screen of the Pilot software, with the expected signal level: The following tolerances must be taken into account:

• ± 2 dB for the transmit power • ± 1 dB for the gain of each antenna • ± 3 dB for the received level measurement displayed on the Pilot • ± 0.5 dB for 1+1 coupler losses

We see that in the worst case, for a 1+0 type system, the maximum uncertainty is ±7 dB (±2 ±1 ±1 ±

3): In practice, the typical uncertainty to be considered is ±5 dB. So, if the difference between the receive level displayed by the Pilot and the receive level expected by

the link budget calculation is within the tolerance ± 5 dB, the installation is considered to be correct. A difference of more than ± 5 dB, however, indicates a problem such as incorrect antenna alignment,

a propagation problem or bad polarization on one of the two antennas. First check the antenna alignment and polarization. If the problem remains, refer to the troubleshooting guide in paragraph 5 and replace the defective element. Record the ODU RSL values of the link on the commissioning form.

Page 44: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 44/134 Sagem Communications document. Reproduction and disclosure prohibited

2.5.3 - Giga Ethernet transmission test

This test is carried out to check for correct transmission of Gigabit Ethernet signals. The test must be carried out on each port used. It is used to test Ethernet transmission over the entire link. A Gigabit Ethernet tester is required to take the measurement. The measurement block diagram is given below:

The Gigabit Ethernet tester is connected to a GE port of the local terminal. On the remote terminal, the corresponding GE output is looped back on the input (by a fibre in case of optical interface or an "RJ45 plug" in case of electrical interface). The "RJ45 plug" consists in connecting wires 1 and 3 together and wires 2 and 6 together. The test consists in measuring the throughput according to RFC 2544 for long enough to check the quality of the link. The test will be declared positive is no packets are lost and if the throughput measured is not less than the limit specified. This limit depends mainly on the configuration: modulation, radio band and number of associated optional E1s.

Choice of transmission configuration

• Define the configuration for each end of the link: modulation, radio channel, number of active E1 tributaries (optional).

Gigabit Ethernet tester

Tx / Rx loopback

Page 45: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 45/134

On the local IDU: The tester must be connected to the GE port to be tested. It is configured as follows:

• Number of Gigabit Ethernet ports to be considered: 1 ⇒ The Ethernet tester is connected to GE port #n of the IDU under test, where n = 1 or 2. ⇒ GE port #n of the IDU must be configured in "Enable" mode. ⇒ Configure the tester so that it takes into account the type of SFP module installed on the

IDU: electrical or optical. If the operator uses optical SFP modules, auto negotiation must be activated on the tester.

• Define a Unicast flow to be transmitted:

⇒ Define the size of this flow. Standard RFC2544 recommends the following sizes: 64, 128, 256, 512, 1024, 1280, 1518 bytes. SAGEM-LINK F-H also supports frame sizes of up to 1760 bytes. Choose one of these sizes.

• Define the test duration. • The throughput defined by standard RFC2544 characterizes the maximum data rate that

can be transmitted without losses. This parameter depends on the transmission configuration (see table in APPENDIX 2) and the associated Ethernet features (e.g. QoS).

• Define a throughput (generally called ILOAD on an Ethernet tester) less than or equal to

the throughput specified for the configuration defined. • The user can choose whether or not to activate radio shaping. When radio shaping is on,

the switch can manage the quality of service. The throughput, however, is less than that observed without shaping. (about 6 % less, irrespective of the configuration).

On the remote IDU:

• Make the physical loopback on GE port #n of the remote equipment. Choice of Ethernet configuration: Configure the equipment as follows:

• Configure each Ethernet port of the equipment as follows: ⇒ Topology: "Y shape" ⇒ Port mode: "Enable" for port #n being tested (local and remote equipment). ⇒ Jumbo mode: "Disable".

Page 46: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 46/134 Sagem Communications document. Reproduction and disclosure prohibited

• The user can choose whether or not to activate radio shaping

If the user configures "Traffic shaping mode" in "Enable" mode, the radio throughput allocated to the Ethernet transmissions is 94 % of the value displayed in the "Radio bandwidth" field. Refer to the table in APPENDIX 2. Set the "Traffic shaping bandwidth" field to 100 % if radio shaping is active.

• Check that there are no SFP alarms (GE LEDs green)

• Launch the tester script (frame loss test): check that no frames are lost.

Page 47: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 47/134

2.5.4 - 2 Mbit/s tributary test (optional) These tests must be carried out on both terminals of the link. A 2 Mbit/s transmission analyzer is required, which must be set with the following parameters:

• BER test • 2 Mbit/s • Internal clock • PRBS: 215-1. • 120 Ohm balanced, or 75 Ohm unbalanced interface depending on IDU configuration.

All channels designed to transport traffic must be tested one by one:

• Click on one of the "TRIB" connectors Shelf view or use the menu: "Configuration / E1 Tributaries / Local"

• Check that the channel under test is configured in normal mode (N), in service (blank button) and no loopback (blank button).

• All other tributaries should be unconnected and configured as inverted (I)

• There should be a "tributary" alarm, the "Trib" LED of the equipment and its image on the Pilot screen must be red.

• Connect the transmission analyzer to the 2 Mbit/s input, respecting the impedance selected

in the IDU. The tributary alarm should now be cleared.

• Click on the "Loopback" button corresponding to the tributary under test. Select a remote loopback. See procedure in § 3.4 -

• Check on the transmission analyzer that no errors occurred for one minute

• When the test is finished, disconnect the cable, change the alarm in invert mode (I) and remove the remote loopback.

• Repeat this test on each 2 Mbit/s channel used on the site.

• Record the results on the commissioning form

Page 48: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 48/134 Sagem Communications document. Reproduction and disclosure prohibited

2.5.5 - Wayside test (optional) The same procedure is used to test the Wayside access and the main Gigabit Ethernet accesses. A 10/100BaseT Ethernet tester is required to perform this test. As when testing the GE ports, make a physical loopback on the remote terminal RJ45 access by connecting pins 1 and 3 together and 2 and 6 together. The test consists in checking that the transmission has no losses on this access at the specified throughput. Note: The throughout is the same irrespective of the configuration (modulation / radio channel). Tester configuration:

• Number of Ethernet ports to be considered: 1 • Configure the tester in 10/100 Mbps auto negotiated mode. • Define a unicast flow of size n bytes. (64 ≤ n ≤ 1760). • Depending on the size of the Ethernet frame to be transmitted, define an ILOAD less than

or equal to the specified throughput in the following table, e.g.: ⇒ For a flow of 64 bytes, the maximum throughput is 1.25 Mb/s. ⇒ For a flow of 1518 bytes, the maximum throughput is 1 Mb/s

Frame size

64 128 256 512 1024 1280 1518 1760 Throughput (Mbps) 1.25 1.05 0.96 0.96 0.96 0.95 0.96 0.96

Configuration common to local and remote equipment: Check that the Wayside port is "on" (box checked) on both IDUs.

Page 49: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 49/134

• Check that there are no Wayside alarms on the equipment (Wayside LED green)

• Start the test (frame loss): check that no frames are lost.

2.5.6 - Alarm relay test (optional)

SAGEM-LINK F-H can manage 5 local external alarms and 5 remote external alarms (image of the 5 external alarms of the remote IDU). If some external alarms are to be managed, it is necessary first to configure them (see § 3.6 -). SAGEM-LINK F-H includes 3 fully programmable relay outputs. Internal or external alarms can be assigned to each relay. If alarm relays and/or external alarm inputs are used on the site, the tests described below must be carried out to check correct operation. These tests must be carried out on each terminal. Before starting the tests, check that no faults are displayed by the equipment. It is not possible to simulate all possible alarms without opening the equipment: for example, simulating a Tx frequency alarm would require opening the ODU and disturbing the transmission synthesizer phase loop. However some alarms can be simulated simply, without having to carry out any operations on the equipment.

2.5.6.1 Simulating an IDU Alarm An IDU alarm can be easily simulated by entering a wrong Link ID code in the local terminal. This wrong ID Code generates an IDU alarm, but does not affect the radio transmission. Apply the following procedure:

• Switch off the local terminal power supply and disconnect the coaxial cable to the ODU • Power up the IDU (ODU not connected) and change the Link ID Code of the local terminal • Switch off the power supply of the local terminal and connect the ODU to the IDU • Switch on the IDU Once the IDU is properly initialized an IDU alarm should be displayed:

front panel "idu" LED, and its representation on the Pilot screen must be red. Once the test is finished, do not forget to put back the correct Link ID code using the same procedure.

Page 50: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 50/134 Sagem Communications document. Reproduction and disclosure prohibited

2.5.6.2 Simulating an ODU Alarm

An ODU alarm can be generated by removing the cable to the ODU. Caution: switch off the power supply before disconnecting the cable. The equipment "ODU" LED and its image on the Pilot screen must be red.

2.5.6.3 Simulating a Gigabit Ethernet Alarm Two alarms can be easily obtained: Take the SFP module out of its housing: an "SFP Presence" alarm is triggered; the equipment "GbE Lnk/Act" LED goes out, the "GE" LED of the Pilot screen and the "SFP Presence" LED in the alarm detail becomes red. Put back the SFP module without the link cable: an "SFP LOS" alarm is triggered; the equipment "GbE Lnk/Act" LED stays lit green, the "GE" LED of the Pilot screen and the "SFP LOS" LED in the alarm detail becomes red.

2.5.6.4 Simulating a tributary alarm A tributary alarm is easily obtained by changing the configuration from normal (N) to invert (I), or vice versa. The equipment "trib" LED and its image on the Pilot screen must be red. When the test is finished, do not forget to restore the initial configuration.

2.5.6.5 Simulating an RSL alarm First check that the ATPC is OFF. An RSL alarm can be simulated by reducing the remote terminal power and choosing a suitable RSL alarm threshold, e.g. -60 dBm. Decrease the remote transmit power in order to have a receive level below -60 dBm. Take care not to drop below the link operating threshold, since the link cannot be restored from the local terminal. The equipment "RSL" LED and its image on the Pilot screen must be red. When the test is finished, do not forget to restore the initial settings.

2.5.6.6 Testing an external alarm To simulate a custom alarm, use the Pilot menu Configuration / Alarms / Local - IDU tab. Depending on the alarm convention, select "N" if a closed loop corresponds to the alarm state, or "I" if an open loop corresponds to the alarm state. In order to test a specific external alarm, first disable all other external alarms. Identify the pin of the 15-pin DB connector corresponding to the alarm input. Assuming that the alarm is in "N" configuration, connect this pin to ground and observe the changes on the front panel of the IDU and on the Pilot screens. The "ext" LED on the IDU front panel and its image on the Pilot screen must be red. Check that the alarm disappears when the pin is disconnected from the ground.

2.5.6.7 Testing the alarm outputs (relays) A multimeter is required for this test, to check continuity between the relay contacts. The 3 contacts of each relay are available on the 15-pin DB connector (see Figure 1.11 and Figure 1.12) When the IDU is not powered, NC is connected to the common point of the relay.

Page 51: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 51/134

When the IDU is powered and when there is no alarm:

• NO is connected to common • NC is in open circuit

When the IDU is powered up and there is an alarm on the relay under test

• NC is connected to Common • NO is in open circuit

Simulate various alarms and test the operation of the relays as explained above.

2.5.7 - Testing 1+1 configuration (optional)

1+1 systems require additional tests compared with unprotected systems. These tests are carried out to check that all parts are operational and that the switching system operates correctly. These tests must be carried out on both ends of the link and require the presence of personnel in each station. In hot standby mode, only one transmitter is active, the other is muted. In frequency diversity mode, the two transmitters operate permanently, transmitting at two different frequencies, and only the receivers are switched. In 1+1 hot standby configuration, since asymmetric couplers are used (6 dB), the default system configuration is revertive automatic switching. In this mode, the transmitter and receiver of the main channel are given priority, operation being switched over to the standby transmitter or receiver in case of fault. When the fault disappears, the system switches back to the main transmitter or receiver. In the figures below, the active transmitter and receiver are written in bold. When the link is in operation and there are no faults, the configuration is as follows: (note: L = local, R= remote).

Tx Main (L)

Rx Main (L)

Tx Standby (L)

Rx Standby (L)

Tx Main (R)

Rx Main (R)

Tx Standby (R)

Rx Standby (R)

Figure 2.5 - Main local transmitter and receiver active

From the local terminal, connect a BER analyzer on one of the 2 Mbit/s channels and make a remote loopback for this channel (see procedure in section 3.4 -). If there is no E1 installed, make a Gigabit Ethernet test as specified in section 2.5.3). Check that there are no errors (or no frame loss) for at least a minute (nominal RSL conditions, ATPC OFF). From the local terminal, in "Super User" mode, select menu "Maintenance/Tx/Rx Forcing" to access the manual switching command (refer to § 4.21 -). Select the standby receiver by clicking on the Rx2 box, and validate.

Page 52: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 52/134 Sagem Communications document. Reproduction and disclosure prohibited

Tx Main (L)

Rx Main (L)

Tx Standby (L)

Rx Standby (L)

Tx Main (R)

Rx Main (R)

Tx Standby (R)

Rx Standby (R)

Figure 2.6 - Main local transmitter and local receiver active

Switching between receivers should be error free. There should be no transmission errors for at least a minute. From the local terminal, in the same menu, select the standby transmitter by clicking on the "Tx2" box. A transmit switching causes errors (or frame losses). The number of errors counted by the BER analyzer should be less than 2 x 10-6.

Tx Main (L)

Rx Main (L)

Tx Standby (L)

Rx Standby (L)

Tx Main (R)

Rx Main (R)

Tx Standby (R)

Rx Standby (R)

Figure 2.7 - Local standby transmitter and receiver active Clear the counter and check that in this configuration, there is are no transmission errors. If revertive automatic switching is on, select automatic switching during transmission and reception by clicking on the "Tx Auto" and "Rx Auto" boxes. The system should return to the main ODU (transmitter and receiver). Errors are generated in case of a transmitter switch. If revertive automatic switching is off, switch on to the main channel manually then click on the "Tx Auto" and "Rx Auto" boxes. The system is now in automatic mode, the orange maintenance LED is off. Use the same procedure from the remote terminal.

2.5.8 - Quality measurement

The link quality can either be measured on a Gigabit Ethernet access or on one or more chained E1 accesses (if the option is installed). Since the bit error rates on the Gigabit Ethernet train and on the E1s are the same, it is simpler to carry out this test on an E1 tributary of the option is installed. The test is either carried out with the arrangement as described in paragraph 2.5.3 - or that described in paragraph 2.5.4 -.

Page 53: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 53/134

For a 1+1 link, only the quality on the main ODUs in automatic switching mode will be tested. The duration of the BER test depends on the type of network and the criticality of the links: Generally:

• 30 minutes for low capacity links (GSM, Wifi, etc.) • 24 hours for medium and high capacity links.

Other durations could be considered upon request, but this will require Sagem approval.

2.5.9 - Recording configuration information

The configuration information can be recorded by the Pilot into files. These files must be attached to the commissioning form Link configuration information Open the "File/System Report" menu, the following screen is displayed:

Page 54: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 54/134 Sagem Communications document. Reproduction and disclosure prohibited

Check all the boxes and click on "Save As". Save the file in the PC using a name indicating the local site and the remote site: "[local site name] – [remote site name].txt". This text file contains information used to configure the local and remote sites, as well as information regarding the hardware and software versions (serial numbers, manufacturing date, versions, etc.). To print the file, click on "Print". Saving local and remote terminal configurations The configurations can be saved in files on the PC. If the IDU or the ODU is replaced, these files can be used to reload the configuration quickly. To configurations are saved via the menu: "File/IDU Configuration/Local or Remote/Save". Chose a file name indicating the names of the sites on the two ends of the link, e.g.: "[local site name] – [remote site name].sav", for the local terminal "[remote site name] – [local site name].sav", for the remote terminal. Configurations are loaded via the menu: File/IDU Configuration/Local or Remote/Load.

Page 55: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 55/134

S SAGEM-LINK F-H

Commissioning Form

Page 1/3

Customer: Link name: Date:

Configuration 1+0 1+1 HSB 1+1 SD 1+1 FD

Modulation

Radio channel

Optional E1s active

QPSK 16QAM 128QAM

28 MHz 56 MHz

0 2 * 4 8 16

* Capacity not available with a 128QAM/56MHz configuration

Giga Ethernet interfaces GE1 SX optical LX optical Electrical

Auto 10 Mbps 100 Mbps 1000 Mbps Full Duplex Half Duplex

GE2 SX optical LX optical Electrical

Auto 10 Mbps 100 Mbps 1000 Mbps Full Duplex Half Duplex

Local site Remote site

Name: Name:

Antenna type: Antenna type:

IDU to ODU cable length: IDU to ODU cable length:

Transmit frequency: Transmit frequency:

Page 56: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 56/134 Sagem Communications document. Reproduction and disclosure prohibited

S SAGEM-LINK F-H

Commissioning Form

Page 2/3

TEST RESULTS

Local site Remote site

Input voltage: VDC Input voltage: VDC

RSL at ODU access (dBm) RSL at ODU access (dBm)

Measured Expected Difference Measured Expected Difference

Main Main

Standby Standby

Giga Ethernet tests: OK NOK Giga Ethernet tests: OK NOK

2Mbit/s tributary tests *: OK NOK 2Mbit/s tributary tests *: OK NOK

Alarms / loops *: OK NOK Alarms / loops *: OK NOK

Wayside *: OK NOK Wayside *: OK NOK

1+1 configuration *: OK NOK 1+1 configuration *: OK NOK

Giga Ethernet quality test

Duration:

Number of frame losses : OK NOK

2 Mbit/s tributary quality tests *

Duration:

Number of Errors: OK NOK

* Note: Optional

Page 57: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 57/134

S SAGEM-LINK F-H

Commissioning Form

Page 3/3

Attached electronic documents

Diskette CD-ROM Other

Reference(s):

File retrieved via the "File/System Report/Save As" menu

File retrieved via the "File/IDU Configuration/Local /Save" menu

File retrieved via the "File/IDU Configuration/Remote/Save" menu

BER measurement file

Other:

Notes

Page 58: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 58/134 Sagem Communications document. Reproduction and disclosure prohibited

3. FINAL LINK CONFIGURATION

Once the link is established, the configuration must be finalized via the Pilot, still in "Super User" mode. The following parameters must still be entered:

• Useful information stored in the IDU memory, e.g. site names and some information which it could be useful to consult or load later.

• Gigabit Ethernet access configuration

• 2 Mbit/s access configuration

• BER and RSL alarm thresholds

• Configuration of local or external alarms, their severity, relays

• Commissioning if necessary and configuration of Automatic Transmit Power Control (ATPC)

• Interleaver configuration

• 1+1 Switching configuration

3.1 - ENTERING SITE NAMES

Enter the site names of the two terminals in "Site Name" (e.g. the equipment IP addresses).

Page 59: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 59/134

3.2 - SETTING THE PILOT DATE AND TIME

Click at the bottom left of the Pilot main screen to display the following screen:

The date of local and remote equipment can be modified.

Click on "Synchronize" then "Apply" to transfer PC date and time to the equipments, independently for the local and remote terminals or for both at the same time.

3.3 - CONFIGURING THE GIGABIT ETHERNET ACCESSES

SAGEM-LINK F-H can be used to transmit Ethernet frames simultaneously or not with 2 Mbit/s tributaries.

The principle for transmission of these frames and the specific functions that can be associated with them are described in § 7-GIGABIT ETHERNET FUNCTION.

3.3.1 - "Configuration / Gigabit Ethernet / Ethernet port configuration / Local or Remote" menu

Open this menu or click on one of the connectors in Shelf view.

Page 60: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 60/134 Sagem Communications document. Reproduction and disclosure prohibited

Topology network mode:

- P2P: allows point to point connection between the GE1 ports of the local and remote equipment. This configuration must be carried out on local and remote equipment.

- Y shape: used to transmit traffic on several GE ports of an IDU to the remote terminal. This configuration must be carried out on local and remote equipment.

Jumbo frame mode: check "Enable" if Ethernet frames are longer than 1760 bytes. Jumbo frame mode is guaranteed for frames of up to 10 000 bytes in P2P and 8192 bytes in Y shape. Jumbo frames are not available with QoS features.

Port Id: select the port to be configured

Port mode: check "Enable" or "Disable"

Interface: Select optical (SX Fiber or LX Fiber) or electrical (Copper) interface

Auto negotiation / Speed / Duplex: for an electrical interface ("Copper" box checked) the transmission speed can be managed automatically (Auto negotiation checked "Enable") or configured manually (Auto negotiation checked "Disable"): 10 Mbps Half Duplex (transmission and reception frames processed separately) or Full Duplex (transmission and reception frames processed simultaneously), 100 Mbps Half or Full Duplex, 1000 Mbps.

3.3.2 - "Configuration / Gigabit Ethernet / Radio channel configuration / Local or Remote" menu

Radio bandwidth: indicates the radio bandwidth available for the designated channel

Traffic shaping mode: check "Enable" to manage QoS and limit the port throughput for radio transmission. Note that when this function is enabled, the maximum throughput available is reduced slightly (about 6 % compared with a configuration without shaping, if shaping bandwidth = 100 %).

Traffic shaping bandwidth: if Traffic Shaping Mode is on ("Enable" box checked), a percentage of the radio bandwidth available can be allocated. If this parameter is set to 100 %, there is no limitation.

Page 61: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 61/134

3.3.3 - "Configuration / Gigabit Ethernet / Advanced configuration / QoS configuration / Local or Remote" menu

Note: this menu can only be accessed if Traffic Shaping is enabled (see § 3.3.2 -) and if Jumbo frame is disabled (see § 3.3.1 -)

Priority mode: used to define the priority of within S-Vlan(s)

- Port priority: all frames entering a GE port have the priority defined in the "Priority" field of the selected port (Low, Normal, High or Very high).

- User priority: the priority assigned to the frames entering the GE port is based on the priority field contained in these frames (User priority). A configurable table gives the mapping between the User priority (UP) field and the priority used within the S-Vlan (service priority) For frames which do not contain this information, the priority defined by default in the "Default QoS" field (Low, Normal, High or Very high) is assigned.

Very high queue priority radio bandwidth: this parameter is used to define the throughput reserved for frames with "Very high" priority.

Page 62: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINPage 62/13

3.3.4 - "Configuration / Gigabit Ethernet / Advanced configuration / Congestion configuration / Local or Remote" menu

Flow control mode: this function is used to prevent frame congestion during the radio transmission whose bandwidth is limited with respect to the throughput at the Gigabit Ethernet access.

Client equipment connected to the GE ports must be configured to manage the pause frames (see § 7).

Metering mode: used to defined a guaranteed throughput per port; metering is guaranteed if the operator configures its quality of service as "Port priority" and if each port has the same priority (if all flows have the same priority; it is strongly recommended to use priorities "Very high" and "High").

Port Id: selects the port on which the CIR will be configured

CIR: configures the throughput guaranteed on each GE port, as a percentage of the radio bandwidth

3.3.5 - "Configuration / Gigabit Ethernet / Advanced configuration / Security configuration / Mac filtering / Local or Remote" menu

F

1o

K F-H Installation and Operation Manual – 253 129 101-01 4 Sagem Communications document. Reproduction and disclosure prohibited

rames with a particular MAC address can be prohibited from transiting in the S-Vlan.

6 MAC addresses can be prohibited; for each address, specific whether it is a source address (SA) r a destination address (DA).

Page 63: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 63/134

3.4 - CONFIGURING 2 MBIT/S ACCESSES

Click on one of the "TRIB" connectors in the Shelf view or open the "Configuration / E1 Tributaries / Local or Remote" menu to open the window used to configure the 2 Mbit/s accesses.

This screen may vary depending on the current capacity. A screen example for a capacity of 16 x 2 Mbit/s accesses is given below:

When this button is "ON", an AIS signal is transmitted when BER > BER Threshold Alarm

I: the access is not used N: The access is used (Normal)

Blank: active (normal) S: AIS transmission

Blank: No loopback L: Local loopback R: Remote loopback

BAL 75: The connector corresponding to this group of tributaries is inbalanced 75 Ohm configuration

Click on the corresponding button to change the settings.

• AIS insert on BER: when this button is ON, an AIS is transmitted when the BER is greater than 10-3.

• Monitoring:

• If the access is not connected, configure it as invert "I". In this case, no alarm is generated since there is no signal at the input. However, if the access is configured as invert, a tributary alarm is generated if a signal is present.

• If the access is used for traffic, it must be configured as normal "N". In this mode, an alarm is generated if there are no signals on the access.

• Service: In normal operation, select "blank" button (active). If "S" is selected, an AIS is returned locally on the reception access of the channel concerned. Note that, in this case, no AISs are transmitted to the remote terminal.

• Loopback: click on a button on the loopback line to display the screen providing access to the various loopbacks: The screen can also be displayed from the "Maintenance / Loopbacks" menu

Page 64: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 64/134 Sagem Communications document. Reproduction and disclosure prohibited

Check one or more boxes to activate local loopback

Click here to activate a multiplexer loopback

Check one or more boxes to activate remote loopback

Click here to apply

Set the loopback time required

From this screen it is possible to activate a local or a remote tributary loopback, or a local multiplexer loopback.

A loopback time can be defined for the link so that it returns to non-looped back mode automatically.

When a remote loopback is activated, a maintenance indication is displayed in the Pilot status bar, the orange "Maint" LED on the IDU front panel and its image on the Pilot are lit.

2 Mbit/s remote tributary loopback

The principle of remote loopback is explained in the following diagram:

2 Mbit/s Input

Local terminal

2 Mbit/s Output

Remote terminal

2 Mbit/s Input

2 Mbit/s Output

Local tributary loopback

Remote tributary loopback

2 Mbit/s Input 2 Mbit/s Output 2 Mbit/s Input

2 Mbit/s Output

Local loopback is used to check the wiring on the local terminal.

Remote loopback is used to check the radio transmission.

Multiplexer loopback (IDU Card)

Multiplexer remote loopbacks operate in the same way as tributary remote loopbacks, except that they are carried out on the resulting train. Remote loopback is used to test multiplexer operation.

Page 65: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 65/134

• Interface: Each 44-pin sub-D connector on the front panel includes the access for eight 2 Mbit/s inputs/outputs. The electrical interface of the accesses can be configured by the Pilot one connector at a time by clicking on the corresponding Balanced 120 / Unbalanced 75 buttons.

3.5 - CONFIGURING THE ALARM THRESHOLDS

BER and RSL alarms thresholds can be adjusted with the Pilot software. Open the "Configuration / Alarms / Local" menu or click on the "Alarms In/Out" connector in the Shelf view.

3.5.1 - BER alarm thresholds

Select the Modem tab.

Two BER thresholds can be configured: BER Alarm (default: 10-3) and BER Warning (default: 10-6)

These thresholds may be modified between 10-3 and 10-6. It is advised to keep the default values.

3.5.2 - RSL alarm threshold

Select the Radio tab.

The threshold can be adjusted between -40 dBm and -70 dBm (default: -60 dBm).

Page 66: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 1Page 66/134 Sagem Communications docu

3.6 - CONFIGURING THE ALARMS

Configuration is carried out via the "Configuration / Alarms / Local or Remote" menu, by clicking on one of the "Relay" LEDs on the Pilot front panel, or by clicking on the "Alarms In/Out" connector on the Shelf view. Six tabs are available to configure the site alarms, their severity, their assignment to a relay and their transmission to the manager.

Whenever a box is checked, an "Apply" window is displayed: click to validate the configuration.

A view of each of the six tabs is given for information or to indicate a special configuration. The meaning of the alarms is described in § 5.5.1 -.

3.6.1 - General parameters On all tabs, each alarm can:

• be assigned to one or more relays if the corresponding boxes are checked; the default assignment of the relays is given in § 3.6.8 -

3 relay outputs are available on the "Alarms IN/OUT" connector. These relays are fully programmable: Internal local alarms or external (local or remote) alarms can be assigned to each relay.

Relay operation can be enabled or disabled by checking or unchecking the "Enable relays" box in "General Parameters"; in the default configuration, the box is checked.

If an alarm is generated the names of the alarm and of the associated relay are written in red.

Click on a Relay box to check or uncheck all boxes in the alarm column in one go.

• Define a severity level: "None", "Warning", "Minor", "Major" or "Critical" by checking the corresponding box. The default alarm severities are indicated in the tables of § 5.5.1 -

• Check the corresponding box "Enable Trap", if you want to send the SNMP trap to network managers. The default configuration is "box checked" for all alarms except for "Link Status" and "Rx Frame".

The traps sent to the network manager can be filtered according to the severity: check the "Disable traps with severity" box corresponding to the severity level you do not want to send the trap to the manager, for all alarms configured at this level; the default configuration is "box unchecked".

The list of managers authorized to manage the equipment traps can be completed by clicking on "Trap Managers". The maximum number of authorized managers in a network is 10.

Add, modify or delete amanager

29 101-01 ment. Reproduction and disclosure prohibited

Enter the IP address of the authorized manager to be added

Page 67: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 67/134

3.6.2 - "IDU" tab

SAGEM-LINK F-H can manage up to 5 external alarm inputs available locally. These signals are connected to the "Alarms IN/OUT" connector. The pinout of this connector is given in § 1.7.2.3.

These five alarms can only be configured locally and named; they will be either:

• "D": the alarm is disabled

• "N": the alarm is configured as normal; there will be no alarms if the corresponding input on the connector is in open circuit, and an alarm will be generated if this input is shorted to the ground.

• "I": the alarm is configured as invert; the alarm state corresponds to open circuit.

SAGEM-LINK F-H can also display locally the 5 alarm inputs from the remote terminal by checking the corresponding box; the "ext" LED of the local IDU will be red. If the status of any activated external alarm changes, the "Ext" LED on the IDU front panel is lit red.

This tab can also be used to display or not an alarm regarding the Wayside channel by checking or unchecking the corresponding box.

Page 68: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 68/134 Sagem Communications document. Reproduction and disclosure prohibited

3.6.3 - "Modem" tab

This tab can also be used to set the BER alarm thresholds (see § 3.5.1 -).

3.6.4 - "Radio" tab

This tab can also be used to set the RSL alarm thresholds (see § 3.5.2 -).

Page 69: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 69/134

3.6.5 - "Tributaries" tab

3.6.6 - "Gigabit Ethernet" tab

Page 70: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 70/134 Sagem Communications document. Reproduction and disclosure prohibited

3.6.7 - "Fans" tab

3.6.8 - Default configuration of the alarm relays

Relays Alarms assigned by default Relay 1 Wayside

Modem alarms Fan alarms

Relay 2 Tributary alarms Giga Ethernet alarms

Relay 3 Radio alarms

Table 3.1 - Default configuration of the alarm relays

3.7 - CONFIGURING THE AUTOMATIC TRANSMIT POWER CONTROL (ATPC)

ATPC is used to increase the density of a network by allowing frequency reuse. This process consists in automatically reducing the transmit power of each transmitter, while keeping good transmission.

ATPC must not be active during antenna installation and commissioning.

ATPC settings depend on the structure of the network (frequency re-use, radio interferers, link margin). The operator must define 3 main parameters:

• Maximum ATPC transmit power

• Minimum ATPC transmit power

• ATPC reception threshold

The minimum and maximum powers must be within the transmitter power ranges, and the difference between maximum and minimum power must not exceed 20 dB.

The ATPC reception threshold must be within the range -50 dBm to -80 dBm.

Page 71: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 71/134

The ATPC process consists in reducing transmit power as low as possible within the specified range while ensuring that there are no transmission errors and that the received level on the remote terminal remains greater than or equal to the specified threshold.

To enable ATPC, click on the ATPC button and set it to "ON".

ATPC parameters are configured via the Configuration / ATPC / Local or Remote / Channel 1 or Channel 2 menu.

Enter the three values and validate with the Apply button.

Note: Use of ATPC with 1+1 Hot Standby Systems

When ATPC is used in a 1+1 system with coupler, the ATPC parameters are defined at antenna access. The power values entered in the above dialog box must take into account the coupler loss.

These values are defined only for the main ODU.

Example: If the ODU can deliver +25 dBm and the loss of a 6 dB coupler on the main path is 2 dBm, the maximum power at antenna access will be +23 dBm for the main ODU.

3.8 - CONFIGURING THE INTERLEAVER

In the default configuration, interleaver is disabled (OFF) in order to minimize data transfer time (latency).

However, when the network does not require a low latency, error correction is improved with the interleaver ons.

To configure the interleaver, double click on the parameter bar at the top of the screen

to open the following window.

Page 72: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 72/134 Sagem Communications document. Reproduction and disclosure prohibited

Click on the ON/OFF button to change the interleaver configuration and validate. The interleaver configuration must be the same on both terminals of the link. So, it is necessary to configure first the remote terminal, then the local terminal.

3.9 - SPECIFIC CONFIGURATIONS FOR 1+1 SYSTEMS Revertive Automatic Switching This option gives priority to the transmitter and receiver of the main channel in 1+1 operation. When this box is checked "ON", the transmitter and the receiver in traffic are those from the main ODU. If there is a fault on the main channel, traffic is switched over onto the standby channel. When the fault on the main channel disappears, the system switches the traffic back to the main channel. Click on the protection button of the Pilot screen or open the "Configuration / Protection / Local or Remote" menu to display the following screen:

When the revertive automatic switching option is not selected, transmit switch and receive switch positions are free. The system stays in the current position until a fault appears. Note that the transmit and receive switches are independent.

Page 73: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 73/134

4. OPERATION – PILOT

SAGEM-LINK F-H operation and maintenance are carried out: - directly on the equipment, via the LEDs on the front panel - from a PC equipped with the Pilot software, or - from a network manager by using SNMP protocol.

This paragraph describes the Pilot screens used to access all functions of SAGEM-LINK F-H equipment.

Click on in the screen to display the front panel of the equipment managed by the Pilot.

This view also provides direct access to several Pilot menus, by clicking on the various elements. For example, clicking on the "Alarms In/Out" connector opens the equipment alarm configuration window. The Pilot menus, available when logged on as "Super User" mode, are described in the following tree structure.

Page 74: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-Page 74/134

For each config Menus in bold

File Ses Alarms Configuration Performance Maintenance

System IDU Confi

Boot FirIDU FirmODU Firm

Qu

Help

LocalRemot

IDU Config

SaveLoad

H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction

ure 4.1 - P ot menu tree structure

uration, the tree structure items include al" or "rem

include submenus

Report guration mware wares wares

it

Open Session Close Session

View Text Log

Graphical Log

Help/Shortcuts Help/About FH HC Pilot

Alarms Management Network

Gigabit Ethernet Protection

ATPC E1 Tributaries

Hardware Inventory Pilot

set to default database

Ethernet Ports and Radio ChaRoutes

Ethernet port configuration Radio channel configuration Advanced configuration

QoS con uration ongestion nfiguration ecurity c figuration Mac filtering

RSL Link Statistics

Gigabit Ethernet Wayside

Clear BER stats

General Ethernet Statistics Metering Statistics

Tx/Rx Forcing Loopbacks

Frequency Scan Try to unmute remote

Restriction

Channel 1 Channel 2

Gigabi et

e

uration

Management Network

Advanced configuration

Security configuration

Gigabit Ethernet Frequency Scan

Channel 1 Channel 2

ATPC

il

fig coon

and disclosure prohibited

ote" submenu.

Fig

the "loc

CS

Re

nnel

sion

t Ethern

Page 75: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 75/134

4.1 - HELP MENU

"Help / Shortcuts" menu: gives the list of functions that can be accessed via keyboard shortcuts.

"Help / About FH HC Pilot" menu: indicates the Pilot software version

Page 76: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 76/134 Sagem Communications document. Reproduction and disclosure prohibited

4.2 - FILE MENU

4.2.1 - "File / System Report" menu This menu can be used to output as hardcopy or save on PC as text file various items of useful information, e.g. configuration data and the detailed composition (serial numbers, hardware and software versions, etc.) of the local and remote sites depending on the boxes checked (see § 2.5.9 -).

4.2.2 - "File / IDU Configuration / Local or Remote / Save" menu This menu can be used to save on PC the local or remote site configurations (cards, alarms, performance, connections, protection, etc.) If the IDU or the ODU is replaced, these files can be used to reload the configuration quickly. Note: Always use a .sav extension for these configuration files.

4.2.3 - "File / IDU Configuration / Local or Remote / Load" menu This menu can be used to quickly load a previously saved IDU configuration, either in the list proposed or in an external file retrieved by "Other file"; in this case, click on "Download".

Page 77: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 77/134

4.2.4 - "File / Boot Firmware / Local or Remote" menu This menu gives the current version of the boot firmware and can be used to load another firmware selected in the list proposed or in an external file retrieved by "Other file"; in this case, click on "Download".

4.2.5 - "File / IDU Firmware / Local or Remote" menu The menu indicates the current version of the IDU firmware and the version stored in reserve bank.

Page 78: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 78/134 Sagem Communications document. Reproduction and disclosure prohibited

Activate reserve firmware: activates the IDU firmware from the reserve bank. Download: downloads a firmware version selected in the list proposed or in an external file retrieved by "Other file"; in this case, click on "Download". After downloading, the Pilot proposes immediate or deferred activation of the new firmware.

4.2.6 - "File / ODU Firmware / Local or Remote" menu The menu indicates the current version of the ODU firmware and the version stored in reserve bank.

Activate reserve firmware: activates the ODU firmware from the reserve bank. Download: downloads a firmware version selected in the list proposed or in an external file retrieved by "Other file"; in this case, click on "Download". After downloading, the Pilot proposes immediate or deferred activation of the new firmware. In 1+1 configuration, the standby ODU is downloaded independently.

4.2.7 - "File / Quit" menu "File / Quit" menu: after confirmation, closes the Pilot software

4.3 - SESSION MENU The "Open Session" and "Close Session" menus are used to open or close a session concerning a link without exiting the Pilot.

Page 79: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 79/134

4.4 - ALARMS MENU

4.4.1 - "Alarms / View / Local or Remote" menu

This menu is used to display all alarms of the local or remote site.

This screen can also be accessed by clicking on one of the alarm LEDs on the Pilot front panel or on

the icon at the top left of the screen. Green LED: no alarm Red LED: alarm Grey LED: no corresponding physical elements or alarm indication not required The meaning of these alarms, their default severity and the corrective action required are indicated in § 5.5.1 -

4.4.2 - "Alarms / Text Log / Local or Remote" menu This menu is used to display two types of record:

- Alarms: date and time when they were triggered, location, severity, alarm type, appearance or disappearance information.

Page 80: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 80/134 Sagem Communications document. Reproduction and disclosure prohibited

- Event log: date and time when the events occurred, location, event type, additional information.

Click on "Save Log" to save the alarm log or the event log on the PC in a .log file which can be kept for consultation. Click on "Reset Log" to clear all records on the "Alarms" and "Events" tabs simultaneously and start a new record. Note: Event dating is based on the Pilot clock which has been preferably synchronized on the clock of

the PC connected.

4.4.3 - "Alarms /Graphical Log / Local or Remote" menu

Page 81: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 81/134

This display is the graphical representation of the alarms contained in the equipment log.

In the top part, check the element for which you want to display a graphical analysis; the alarm statuses are plotted in red. Zoom in with the mouse wheel if required. Click on "Reset Log" to clear all records simultaneously and start a new record. Note common to § 4.4.2 - and 4.4.3 -: the log information is stored in the IDU flash memory. The IDU flash memory is limited to 2048 alarm transitions or events. When the log is full, the oldest alarms or events are overwritten by the most recent. When the equipment is off, the log is kept in the flash memory.

4.5 - CONFIGURATION / ALARMS MENU This menu is described in § 3.6 -.

4.6 - CONFIGURATION / MANAGEMENT NETWORK / ETHERNET PORTS AND RADIO CHANNEL / LOCAL OR REMOTE MENU

4.6.1 - Description of the Management network SAGEM-LINK F-H equipment can be operated via an SNMP type management network, via the Pilot software, and an SNMP manager (IONOS NMS). The equipment can be managed via the integrated network management interface acting as an IP router:

Network management

interface Switch

L2

Ethernet

MGMT1

MGMT2

TSL/PPP (to remote IDU)

The router has two ports:

- The IDU management Ethernet port (MGMT1 or MGMT2), associated with a MAC address. This MAC address is unique and non modifiable. An IP address is associated with this MAC address.

- The radio port (TSL) communicating with the remote IDU via a PPP type protocol. To make the management system easier to implement, the IP addresses of these ports are managed internally and are transparent for the user.

Page 82: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 82/134 Sagem Communications document. Reproduction and disclosure prohibited

To make the terminals easier to identify, a virtual IP address is defined for each terminal (terminal = IDU+ODU). This address will be used by the Pilot software and the network manager to identify the terminal. This address is independent of the IDU Ethernet port address and must not belong to the same subnet. This address is called the Management IP Address. The IDU Ethernet port IP address does not operate with SNMP, since the equipment always answers with the management address. A SAGEM-LINK F-H equipment can be connected via the IDU Ethernet interface to another equipment, whether or not SAGEM-LINK F-H. To route the datagrams on the various network elements, the routes to reach these elements must be defined. A route is defined for an IP network; e.g. 135.11 if the network mask is 255.255.0.0. The network entities can exchange their routes using the RIP and OSPF protocols. On IDU PPP interfaces, the OSPF protocol is systematically implemented. On IDU Ethernet interfaces, the user have to define whether or not to involve RIP or OSPF protocols. Static routes and a default gateway can be also be defined for each IDU.

Network management interface configuration examples

- One hop link The manager is connected to the IDU of site A via the Ethernet access. The IDU of site B may be connected to a laptop for local maintenance.

Laptop

Site A Site B

Manager

Ethernet

Eth TSL Manager

Eth TSL Laptop

10.0.0.10

10.0.0.1

192.168.114.11

2.0.0.2

2.0.0.10

OSPF

192.168.114.12

Page 83: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 83/134

- Two hop link

Site A

Site B Manager

Ethernet

Site C

Laptop

Eth TSL Manager

Eth TSL

10.0.0.10 255.255.255.0

10.0.0.1 OSPF

192.168.114.11

Eth TSL Eth TSL 10.0.1.1

PC

Static route 192.168.114.x /255.255.255.0 => 10.0.0.1

2.0.0.2 255.255.255.0

2.0.0.3 255.255.255.0

10.0.1.10 255.255.255.0

OSPF

192.168.114.12

Static route 192.168.114.x /255.255.255.0 => 10.0.1.1

192.168.114.14 192.168.114.13

Page 84: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 84/134 Sagem Communications document. Reproduction and disclosure prohibited

4.6.2 - Network configuration

The meaning of the configuration parameters is described in the previous paragraph. On system initialization, the addresses are entered via the serial interface (VT100). These values can then be modified via the Pilot or the manager, but in this case, note that if an incorrect value is entered via a remote terminal, it will be impossible to reach the equipment and intervention on site will be required to put back the correct address. Port Id: used to display the statuses of the MGMT1, MGMT2 and Wayside ports

4.6.3 - Wayside configuration The Wayside is a point to point 10/100BaseT Ethernet channel between the local and remote equipment. This access can be physically disconnected by setting the "Wayside transmission" setting to "Off".

Page 85: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 85/134

4.7 - CONFIGURATION / MANAGEMENT NETWORK /ROUTES / LOCAL OR REMOTE MENU

This table lists the IP routes known by the equipment. Direct routes are known due to the configuration of the equipment interfaces. Indirect routes may result from the routing protocol (OSPF or RIP) or definition of a static route.

To add a static route, click on "Add"

The IP network to be reached is defined by the "Destination Address" and "Subnet Mask" fields

For example: 10.142.0.0 / 255.255.0.0

The "Gateway" field is the equipment address to which network frames will be sent.

If the Ethernet interface is to be used, the Gateway address must be in the Ethernet interface network; the MAC address of the Gateway will be used to reach it.

If the TSL (PPP) interface is to be used, the Gateway address must be the remote equipment management address.

Cost: defines the cost of using the route.

There is a maximum of 20 static routes.

Page 86: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 86/134 Sagem Communications document. Reproduction and disclosure prohibited

4.8 - CONFIGURATION / GIGABIT ETHERNET MENU

This menu is described in § 3.3 -.

4.9 - CONFIGURATION / PROTECTION / LOCAL OR REMOTE MENU

SAGEM-LINK F-H IDU is common to the 1+0 and 1+1 configurations. The hardware difference is that the 1+0 IDU uses only one modem while the 1+1 IDU contains two. There are two ways to establish a 1+1 link: - On first installation: with the two modems inserted in the IDU each modem being connected its ODU a cable. Switch on both modems to power up the terminal. - On a 1+0 link already established: there is no need to disconnect the link; install Modem2/ODU2 and switch on the second Modem. Then, to switch from one configuration to the other, use the Pilot software as described below.

• Click on the protection button of the Pilot screen or open the "Configuration / Protection / Local or Remote" menu to display the following screen:

• Select the box corresponding to the new configuration and validate.

• If the changeover is refused, there may be a hardware problem or the two ODUs may not be compatible with the required 1+1 mode (e.g. different ODUs in 1+1 HSB, etc.)

Perform these operations on the local and remote equipment. Note: It is important to have both terminals in the same configuration. Avoid having the two terminals in different configurations. The various system configurations are described in § 1.5 - Revertive automatic switching: see § 3.9 -

Page 87: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 87/134

RSL switching threshold: The RSL switching criterion is only active for space or frequency diversity configurations. In 1+1 hot standby configurations, this criterion is not taken into account. Enter the RSL switching threshold If the receive level of both receivers is greater than this threshold, the RSL switching criterion is not taken into account by the switching system. If the RSL of one receiver is below this threshold and if the two other criteria (alarm and BER) are the same on both channels, then the system selects the receiver with the best receive level. If the levels of both receivers are below the threshold and if the other criteria (alarm and BER) are the same on both channels, then the system permanently selects the receiver with the best receive level.

4.10 - CONFIGURATION / ATPC / LOCAL OR REMOTE MENU

This menu is described in § 3.7 -.

4.11 - CONFIGURATION /E1 TRIBUTARIES / LOCAL OR REMOTE MENU

This menu is described in § 3.4 -.

4.12 - CONFIGURATION / HARDWARE INVENTORY / LOCAL OR REMOTE MENU This screen gives the equipment hardware inventory (references, serial numbers, components manufacturing dates) and main ODU features.

Page 88: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 88/134 Sagem Communications document. Reproduction and disclosure prohibited

4.13 - CONFIGURATION / PILOT MENU

This menu can be used to display/hide tool tips when pointing the mouse on the various screen parameters.

4.14 - CONFIGURATION / RESET TO DEFAULT DATABASE / LOCAL OR REMOTE MENU This menu is used to restore the system factory settings.

4.15 - PERFORMANCE / RSL / LOCAL OR REMOTE MENU

This graph displays the ODU minimum and maximum RSLs over time and the number of seconds during which the high and lower configurable thresholds have been crossed.

Zoom in with the mouse wheel if required. Clear: clears the graph and starts a new record.

Page 89: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 89/134

4.16 - PERFORMANCE / LINK STATISTICS / LOCAL OR REMOTE MENU

This graph displays the link performance log for measurement periods of 1 min, 15 min or 24h, either in number of seconds or as a percentage of the period.

Quality processing is carried out by calculating and determining various states: ES (Errored Second), SES (Severely Errored Second) and UAS (UnAvailable Second).

Quality counters ES, SES and UAS:

The quality counters are as follows:

ES (Errored Seconds): number of seconds with at least one error detected within a period of 1 s or a fault,

SES (Severely Errored Seconds): number of severely errored seconds An SES is a second during which the number of errors exceeds the threshold defined or during which at least one fault is detected.

UAS (UnAvailable Second): number of unavailable seconds, Zoom in with the mouse wheel if required.

Clear: clears the graph and starts a new display

Page 90: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 90/134 Sagem Communications document. Reproduction and disclosure prohibited

4.17 - PERFORMANCE / GIGABIT ETHERNET / GENERAL ETHERNET STATISTICS / LOCAL OR REMOTE MENU

This menu displays the statistics counters of the Ethernet ports.

Reset counters: resets the counters and starts a new count.

4.18 - PERFORMANCE / GIGABIT ETHERNET / METERING STATISTICS / LOCAL OR REMOTE MENU

The IDU board supplies counters indicating the quantity of valid (green) and unvalid (red) traffic received on a port. Green Bytes: Number of received bytes while guaranteed rate (CIR) is not exceeded. Red Bytes: Number of received bytes while guaranteed rate (CIR) is exceeded.

Reset counters: resets the counters and starts a new count.

Page 91: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 91/134

4.19 - PERFORMANCE / WAYSIDE / LOCAL OR REMOTE MENU

This menu is used to display the number of bytes transmitted and received on the Wayside Ethernet port.

Reset counters: resets the counters and starts a new count.

4.20 - PERFORMANCE / CLEAR BER STATS / LOCAL OR REMOTE MENU

This menu resets the local or remote BER counters and starts new counts.

4.21 - MAINTENANCE / TX/RX FORCING MENU

Only active for 1+1 links, this menu can be used to perform manual transmit or receive switching. Clicking on the Equipment Forcing menu displays the following windows:

Transmit and Receive switches are independent. A system can work with main ODU (1) transmitting, and standby ODU (2) receiving. In normal position, switching is carried out automatically. In manual mode, the equipment is in maintenance mode (maintenance indication at the bottom of the Pilot screen and orange LED flashing on the IDU front panel). To perform manual switching commands (forcing), click on the box corresponding to the transmitter or receiver to be activated and validate with OK.

The main Pilot screen indicates the transmitter and the receiver in traffic.

Page 92: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 92/134 Sagem Communications document. Reproduction and disclosure prohibited

4.22 - MAINTENANCE / LOOPBACKS MENU

This menu is used to make loopbacks on the 2 Mbit/s channels or on the resulting signal. This menu is described in § 3.4 -.

4.23 - MAINTENANCE / FREQUENCY SCAN / CHANNEL 1 OR CHANNEL 2 MENU

This menu is used to carry out a frequency scan around the receive frequency, in order to identify possible radio interferers. The measurements results are displayed graphically and stored in memory for future consultation. The process is carried out separately on each terminal. The user defines the frequencies to scan. The local transmitter is muted, while the receiver measures the Receive Signal Levels for each frequency. Clicking on the "Frequency scan" menu displays the following window:

Click here to start a frequency scan Definition of the frequency range to be scanned

The active transmitters and receivers are shown in bold

Page 93: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 93/134

4.24 - MAINTENANCE / TRY TO UNMUTE REMOTE / LOCAL OR REMOTE MENU

This menu is not permanent; it is displayed when the radio link has been lost. The bar at the bottom of the Pilot screen is used to access this menu to try to unmute the link.

4.25 - MAINTENANCE / RESTRICTION / LOCAL OR REMOTE MENU

This menu is used to extend the SAGEM-LINK F-H capacity. The following options are available:

- 70 Mbps corresponding to a 16 QAM / 28 MHz configuration - 150 Mbps corresponding to a 128QAM / 28 MHz or 16 QAM / 56 MHz configuration - 300 Mbps corresponding to a 128 QAM / 56 MHz configuration

It is possible to upgrade to a higher capacity by purchasing a license. A software code supplied by SAGEM Communications is used to update the terminal. A code depending on the modem serial number must be entered modem by modem (2 codes for a 1+1 configuration) A window indicates the current maximum configuration for each modem (modulation / radio bandwidth). Please note that in 1+1 configuration, the lower modem configuration is taken into account.

Page 94: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 94/134 Sagem Communications document. Reproduction and disclosure prohibited

5. TROUBLESHOOTING GUIDE

5.1 - INTRODUCTION

This paragraph helps you solve problems using the information available (front panel LEDs and Pilot software) and describes the procedures for replacing defective units. Main points discussed:

• Visual inspection • Description of front panel alarm LED operation • Troubleshooting procedure • Alarms managed by the Pilot • Typical screens in case of problem • Replacing an ODU • Replacing a Modem • Replacing an IDU

Measurement equipment required

• Laptop with serial port • Pilot software • Gigabit Ethernet tester • 2 Mbit/s transmission analyzer (optional) • Ethernet tester • Digital multimeter

5.2 - VISUAL INSPECTION Before starting the operation, it is important to perform a visual inspection of the terminal and its installation.

Visual inspection Look for Actions

IDU / ODU coaxial cable Cuts, short circuits, moisture in connectors

Clean or repair

IDU and ODU Dust, humidity, lightning strike damage

Clean or replace Clean the fans regularly

Alarms (front panel and Pilot) No red LEDs lit If some alarms are red, use this troubleshooting guide (§ 5.4 - and 5.5 -)

Receive Signal Level (Pilot) Nominal value (installation data) Realign antenna, check remote terminal transmit power

Power supply voltage Within specified range Replace power supply

Antenna mounting Tight mount Mount antenna correctly

Page 95: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 95/134

5.3 - TROUBLESHOOTING PROCEDURE The goal is to make a precise diagnostic of the problem, in order to determine the faulty unit quickly and replace it.

5.3.1 - Describe the symptom

This is generally made by the field technician: common symptoms are "the link is broken", "there are excessive transmission errors", "there are alarms", etc. These symptoms may be permanent (failure) or intermittent. The alarm and event data and the graphic records available in the Pilot can generally be used to improve the diagnostic (§ 4.4 -).

5.3.2 - Isolate the problem

Once the symptom has been defined, the faulty unit can be isolated using information supplied by the LEDs on the IDU front panel and the information available on the Pilot. SAGEM-LINK F-H replacement units are the ODU, the IDU (without modem and without FAN), the modem and the FAN drawer. A 1+0 link is composed of several units. The goal of this step is to determine what the most probable unit to replace is. The difficulty is that, in some cases, the problem may be generated by the remote terminal, external equipments (power supplies, bad interface signal levels, etc.) or the external environment (path obstruction, radio interferers, severe climatic conditions, etc.).

5.3.3 - Fix the problem

Once the problem has been isolated, it is important to understand its cause and to apply corrective actions to avoid reoccurrence of the problem. Some typical problems are described in § 5.6 -.

5.4 - DESCRIPTION OF IDU FRONT PANEL LEDS

The LEDs on the IDU Front panel and the modem are shown below:

Maint idu trib ext

MODEM

ODU

RSL

POWER

GbE Lnk/Act 1 2 3 4 FAN

Figure 5.1 - IDU front panel LEDs

Page 96: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 96/134 Sagem Communications document. Reproduction and disclosure prohibited

5.4.1 - Description of IDU LEDs

• "maint" LED is orange during a maintenance operation (remote loopback, manual control of 1+1 switching). It is off in normal mode.

• "idu" LED is red when there is multiplexer or a demultiplexer failure, when receive data is not recovered (link broken), or if there is no fan drawer installed.

• "trib" LED is red if there is no input signal on a tributary configured as normal, or if there is an input signal on a tributary configured as inverted.

• "ext" LED is red if there is a status change on one of the external alarms which have been associated with this LED (see § 3.6 - for a description of this alarm).

• "GbE Lnk/Act" LEDs 1 to 4 are dedicated to the Gigabit Ethernet transmission

• LED off: link down • Green LED lit permanently: link up • Green LED flashing: traffic indicator, flashes for each GE frame • Orange LED lit: collision

• The "FAN" LED is red if the FAN module or one of the fans is faulty.

5.4.2 - Description of the Modem front panel LEDs

• The " MODEM" LED is red if there is a problem on the ODU cable, if the modulator, demodulator or power supply is faulty, or if the link is down (no received data).

• The "RSL" LED is red if the level received by the ODU is below the programmed threshold, or if there is a BER alarm (BER alarm, or BER warning). In most cases, this alarm corresponds to a propagation or radio interferer problem.

• The "ODU" LED is red if there is an ODU alarm or if an ODU is not connected (cable problem). The LED is also red if the ODU is muted on a 1+0 link or if the two ODU of a 1+1 link are muted.

• The "POWER" LED is green when the modem is powered up.

5.5 - ALARMS MANAGED BY THE PILOT

The Pilot software provides more details than the LEDs on the front panel of the equipment.

5.5.1 - Alarm summary screen Click on the "Alarms / View / Local or Remote" menu to access the alarm summary screen. The active alarms are red. This screen can also be accessed by clicking on one of the alarm LEDs on the main Pilot screen.

Click on the icon at the top left of the screen to access the local alarm display window.

Page 97: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 97/134

Figure 5.2 - Alarm screen on the Pilot

Green LED: no alarm Red LED: alarm Grey LED: no corresponding physical elements or alarm indication not required The meaning of these alarms, their default severity and the corrective action required are indicated in the following tables.

Page 98: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 98/134 Sagem Communications document. Reproduction and disclosure prohibited

IDU alarms Description LEDs on the

equipment Default alarm

severity Corrective actions

Wayside No input signal Wayside access LED

(§ 1.7.2.4)

None Check cable

Table 5.1 - Meaning of the Wayside alarm Radio link alarms

Description LEDs on the equipment

Default alarm severity

Corrective actions

Link ID This alarm is present if local and remote ID Codes do not match. The receive data is replaced by an AIS.

IDU

Minor

Check that the remote terminal has the same Link ID. If the Link IDs of the 2 terminals do not match, they are displayed in red on the main Pilot screen; if identical they are displayed in black. If the alarm remains, another link operating at the same frequency may be disturbing the link.

Link Status This alarm indicates that the dialog is interrupted between local and remote equipment

Depends on alarm origin

Major Examine the various alarms on the 2 terminals of the link to improve the diagnostic

Rx Frame Indicates that the INT demultiplexer is unlocked

Depends on alarm origin

Major Examine the various alarms on the 2 terminals of the link to improve the diagnostic

Table 5.2 - Meaning of radio alarms

Page 99: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 99/134

Fan / temperature alarms

Description LEDs on the equipment

Default alarm severity

Corrective actions

Fans This alarms is triggered if there a fan or FAN module fault or if there is no fan drawer

FAN idu (absence)

Major Replace faulty or missing unit.

IDU Temperature

This alarm is triggered when the IDU temperature is greater than the maximum permitted value

FAN

Major

Look for the possible alarm causes: IDU faulty or room too hot.

Modem 1 Temperature

This alarm is triggered when the temperature of the main modem is greater than the maximum permitted value

FAN

Major Look for the possible alarm causes: IDU or modem 1

faulty or room too hot.

Modem 2 Temperature

This alarm is triggered when the temperature of the standby modem (1+1 configuration) is greater than the maximum permitted value

FAN

Major Look for the possible alarm causes: IDU or modem 2

faulty or room too hot.

Table 5.3 - Meaning of Fan and Temperature alarms

Page 100: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 100/134 Sagem Communications document. Reproduction and disclosure prohibited

Modem alarms Description LEDs on the

equipment Default alarm

severity Corrective actions

Demodulation This alarm is generated if there is a demodulator fault or if received data is not recovered

MODEM

Major

Check all alarms on both terminals to find the cause of the problem, as well as possible propagation problems.

Modulation This alarm is generated if there is modulator fault. When a modulation alarm occurs, the transmitter is automatically muted.

MODEM

Major

Replace the modem

BER alarm This alarm is generated when BER is greater than the programmed threshold (default 10-3). A BER alarm can be generated by a poor receive level, a modem fault or radio interference

MODEM, RSL

Major

Check other parameters such as the RSL, remote terminal alarms and possible propagation problems.

BER warning This warning is generated when BER is greater than the programmed threshold (default 10-6).

MODEM, RSL Minor Check other parameters such as the RSL, remote terminal alarms and possible propagation problems.

Table 5.4 - Meaning of Modem alarms

Page 101: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 101/134

ODU alarms Description LEDs on the

equipment Default alarm

severity Corrective actions

RSL (Receive Signal Level)

This alarm is generated when the RSL is below the programmed threshold (default threshold: -60 dBm). It may also be generated in case of a power problem on a remote transmitter, a propagation problem, or a faulty receiver.

RSL

Minor

Use the indications on the remote terminal such as RSL and alarms to make a diagnostic.

Power supply Power supply alarm returned by the ODU. This alarm indicates an ODU power supply fault or input voltage too low

ODU

Minor

Check power supply voltage (-48 V) and cable losses. If the power supply voltage and the cable are OK, replace the ODU

Cable Cable alarm returned by the ODU. This alarm is generated if the transmit IF level at ODU input is outside the limits.

ODU

Minor

Check IDU / ODU cable losses. Replace the modem or the ODU.

Tx Frequency This alarm is generated in case of transmit synthesizer fault. This alarm automatically mutes the transmitter.

ODU

Major

Replace the ODU

Rx Frequency This alarm is generated in case of receive synthesizer fault.

ODU Minor Replace the ODU

Tx Power A transmit power alarm is generated in case of a transmitter AGC loop fault, or in case of a transmitter mute set by the operator (in 1+1 system when both transmitters of a terminal are in mute position).

ODU

Minor

If the transmitter was not muted deliberately and the fault remains, replace the ODU

Mute Tx Power alarm present User configuration

ODU Minor If the transmitter was not muted deliberately and the fault remains, replace the ODU

Table 5.5 - Meaning of ODU alarms

Page 102: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 102/134 Sagem Communications document. Reproduction and disclosure prohibited

Gigabit Ethernet alarms

Description LEDs on the equipment

Default alarm severity

Corrective actions

SFP Presence Module absent Gbe Lnk/Act off

Major Plug in the module correctly or replace it of faulty

SFP Type Mismatch

The SFP module inserted is not that expected Gbe Lnk/Act off Major Insert the correct module or change the configuration

SFP LOS Loss of input signal Gbe Lnk/Act green Major Check cable SFP Tx Default Ethernet link assembly fault (e.g. auto

nego FAIL, cannot transmit in Tx) Gbe Lnk/Act off

Major Make sure that the Ethernet link cable (fibre or RJ45) is not faulty. Also check the SFP module.

Table 5.6 - Meaning of Gigabit Ethernet alarms E1 tributary alarms

Description LEDs on the equipment

Default alarm severity

Corrective actions

Trib Alarm This alarm is generated when there is no input signal for a tributary configured as normal (N), or when there is an input signal for a tributary configured as inverted (I).

trib

Major

Check tributary alarm configuration, cable continuity and presence of signal at output of equipment connected to SAGEM-LINK F-H.

Table 5.7 - Meaning of E1 Tributary alarms External alarms

Description LEDs on the equipment

Default alarm severity

Corrective actions

Ext_Local_x (x=1 to 5)

External alarms (local terminal incoming loops), alarms concerning the 5 local external alarm inputs configured (see § 3.6.2 -)

ext

Major

Check generating event: e.g. door open, etc.

Ext_Distante_x (x=1 to 5)

External alarms (remote terminal incoming loops), alarms concerning the 5 remote external alarm inputs configured (see § 3.6.2 -)

ext

Major

Check generating event: e.g. door open, etc.

Table 5.8 - Meaning of External alarms

Page 103: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 103/134

5.5.2 - Direct and indirect alarms There are two types of alarm in a microwave radio link:

• Direct alarms which occur when there is a fault on a unit (e.g. transmit frequency alarm)

• Indirect alarms caused by a fault on another unit or by an external problem To determine the cause of an indirect alarm, analyze all possible causes of the alarm and select the most likely

5.5.3 - Event log

In some cases with transient faults, it may be worthwhile examining the graphic log available and the alarm or event data to determine the cause of the fault (§ 4.4 -)

5.6 - TYPICAL SAGEM-LINK F-H PILOT SCREENS IN CASE OF PROBLEM The following screens are representative of some typical problems.

5.6.1 - No IDU-Pilot software communication When connecting the IDU to the PC, the following screen may be displayed:

The Pilot cannot communicate with the IDU. Check the Ethernet cable between IDU and PC and check that the IP addresses and subnet masks of the PC and the IDU are compatible. From the PC, ping the IDU Ethernet address. If the ping result is negative, change the IP address of the PC or of the IDU Ethernet port (see § 2.2 -).

5.6.2 - No local equipment, no remote equipment

If the connection between PC and IDU breaks during a Pilot session, the Pilot displays the following screen:

Check that that the IDU is powered correctly and that the Ethernet cable between the PC and the IDU is correctly installed.

Page 104: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 104/134 Sagem Communications document. Reproduction and disclosure prohibited

5.6.3 - No local radio

The IDU is recognized by the Pilot, but the ODU does not operate: absent, faulty or not answering the IDU requests. In this case, the typical Pilot screen is as follows:

Check the cable between IDU and ODU. If the problem remains, replace the ODU or the modem.

5.6.4 - No remote radio The local terminal operates correctly but communication with the remote terminal is down. In this case, the typical Pilot screen is as follows:

Check the remote terminal configuration (frequency, capacity, modulation, transmit power), correct antenna alignment and possible presence of obstacles between the two antennas. In the bottom bar, the software suggests trying to "unmute" the remote equipment, which could be one of the reasons why it fails to operate. Go to the maintenance menu to access this command.

Page 105: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 105/134

5.6.5 - Low RSL

The link is established but the RSL is low. The typical Pilot screen is as follows:

Check antenna alignment, transmit power levels and make sure that the fault is not due to a temporary propagation problem.

5.6.6 - Low transmit power The RSL of one of the two terminals is too low with respect to the other terminal. In this case, the typical Pilot screen is as follows:

Increase the transmit power if possible. If the problem remains, replace the ODU on the site with the doubtful transmitter.

Page 106: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 106/134 Sagem Communications document. Reproduction and disclosure prohibited

5.6.7 - Link established correctly but with some alarms

Check the alarm configuration (§ 3.6 -).

5.6.8 - Normal link no alarms The link is established without alarms. All LEDs are green.

5.7 - REPLACING AN ODU Apply the following procedure: 1- Switch off the modem connected to the ODU (check that the green modem LED is off). 2- Disconnect the ODU cable (IDU side). 3- Before removing the ODU, note the position of the arrow on the ODU cover, disconnect cable 4- Replace the ODU with another one of the same type according to the installation procedure (§ 1.5 -),

respecting the polarization (arrow in the same position as before). Replace the gasket (antenna or coupler interface) if damaged.

Page 107: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 107/134

5- Connect the cable and protect N connector with isolation tape. 6- Connect the cable on the IDU side and switch on the modem.

Caution: Before connecting or disconnecting the cable between IDU and ODU, check that the modem is off (green LED off).

Note: For a 1+1 system, an ODU can be replaced with the second one operating. Before replacing an

ODU, select manual switching on the transmitter and the receiver, which continue to operate (see § 4.21 -). Once the change has been done, return to automatic switching.

5.8 - REPLACING A MODEM

Apply the following procedure: 1- Switch off the modem connected to the ODU (check that the green modem LED is off). 2- Disconnect the ODU cable (IDU side). 3- Remove the two screws 4- Remove the modem and replace by a new one 5- Attach the modem with the screws and connect the cable to the ODU 6- Power up the modem

Caution: Before connecting or disconnecting the cable between IDU and ODU, check that the modem is off (green LED off).

Note: For a 1+1 system, a modem can be replaced with the second one operating. Before replacing it,

select manual switching on the transmitter and the receiver, which continue to operate (see § 4.21 -). Once the change has been done, return to automatic switching.

5.9 - REPLACING AN IDU

Apply the following procedure: 1- Load the configuration file saved previously to avoid having to reconfigure everything (see § 4.2 -) 2- Switch off the modem(s) 3- Remove all cables from the IDU 4- Remove the IDU. 5- Remove the modem(s) from the IDU and install them in the new IDU. 6- Install the new IDU and reconnect all cables. 7- Switch on the IDU and load the configuration file.

Page 108: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 108/134 Sagem Communications document. Reproduction and disclosure prohibited

6. SYSTEM DESCRIPTION

6.1 - INTRODUCTION

The SAGEM-LINK F-H range of microwave radio links provides highly reliable point to point communication with low installation costs in different frequency bands. This high-capacity range of microwave frequencies is characterized by excellent flexibility in terms of transmission capacity and the frequency bands used. It allows simultaneous or independent transport of Giga Ethernet data and 2Mbit/s links by PDH/Ethernet multiplexing associated with a 150 or 300 Mbps bandwidth. SAGEM-LINK F-H equipment is available in unprotected 1+0 configuration or in protected 1+1 configuration (hot standby, space diversity, frequency diversity).

• Main telecommunication bands covered: 6, 7, 8, 11, 13, 15, 18, 23, 26, 32 and 38 GHz

• 2 Gigabit Ethernet Interfaces + 16 E1 accesses on option Data rates: 70, 150 and 300 Mbps

• Modulation: QPSK, 16QAM, 128QAM

• Radio channel: 28 MHz, 56 MHz

• Integrated BER and receive signal level measurement

• Wide transmit power range in steps of 0.5 dB

• Automatic Tx Power Control (ATPC algorithm)

• Synthesizer frequency step: 250 kHz

• Full software control

• Full compliance with ETSI standards Other features available:

• 1 Wayside 10/100BaseT Ethernet channel

• 5 external alarm inputs and 3 configurable relay outputs

• 1 management interface with two 10/100BaseT Ethernet ports connected by an integrated switch

• 1 VT100 configuration RS232 interface

6.2 - DESCRIPTION

6.2.1 - System composition

All SAGEM-LINK F-H configurations are built from standard units installed in a 19" 1U chassis.

• An IDU (Indoor Unit) composed of: • A Backplane connecting the various IDU units • An INT4 base board providing the various IDU accesses: Giga Ethernet, Wayside, external

alarm and relay outputs, serial management ports, PC access

• An optional TNM4 board (daughter board) inserted on the base board and providing 16 x 2 Mbit/s accesses

• A directly pluggable ½U MODEM providing the cable interface with the IDU; two modems are installed in the chassis for a 1+1 configuration, associated with two ODUs

• an extractible FAN module with three fans to cool the IDU, powered directly by the -48 V.

Page 109: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 109/134

• An ODU (Outdoor Unit) providing the cable interface with the IDU and supporting the frequency radio circuits (synthesizers, transmitter, receiver).

A 1+0 terminal using an integrated antenna is presented on Figure 6.1 and a 1+1 terminal using a coupler is presented on Figure 6.2.

IDU Modem

ODU

Integrated antenna

Fan

Figure 6.1 - SAGEM-LINK F-H 1+0 terminal

Page 110: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 110/134 Sagem Communications document. Reproduction and disclosure prohibited

Main ODU

IDU Main modem

Standby modem

Standby ODU 1+1 coupler

Integrated antenna

Fan

Figure 6.2 - SAGEM-LINK F-H 1+1 Terminal (HSB)

6.2.2 - IDU version

• UFX-SP: GE chassis (GE configurable up to 300 Mbps)

• UFE-16E1: Optional 16E1 extension board (TNM4)

6.2.3 - Modem version

• UFC-HW: QPSK, 16QAM or 128QAM controlled by software

6.2.4 - Fan version

• UFF: hot swap fan module.

Page 111: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 111/134

6.2.5 - ODU Versions

SAGEM-LINK F-H equipment is available in frequency bands 6 GHz, 7 GHz, 8 GHz, 11 GHz, 13 GHz, 15 GHz, 18 GHz, 23 GHz, 26 GHz, 32 GHz and 38 GHz.

Each frequency band is divided into several sub-bands. For each sub-band, there is one Low Band ODU and one high band ODU.

The complete list of ODUs is given in APPENDIX 3 § References of SAGEM-LINK F-H ODUs.

The ODU minimum and maximum frequencies indicated in this list correspond to the duplexer useful bandwidth.

The minimum and maximum channel frequencies depend on the channel occupied bandwidth and therefore on the capacity and the modulation used.

The following diagram summarizes the rules used to determine the minimum and maximum depending on the channel type used: see figure below.

ODU bandwidth

56 MHz radio channel

20 MHz

Fmin56 = FminODU+20

28 MHz radio channel

10 MHz

Fmin (ODU) Fmax (ODU)

20 MHz

10 MHz

Fmax28 = FmaxODU-10

Fmax56 = FmaxODU-20

Fmin28 = FminODU+10

Figure 6.3 - Minimum and maximum channel frequencies

• For a 56 MHz radio channel, the minimum frequency is: FminODU + 20 MHz and the maximum frequency is: FmaxODU -20 MHz

• For a 28 MHz radio channel, the minimum frequency is: FminODU + 10 MHz and the maximum frequency is: FmaxODU -10 MHz

Page 112: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 112/134 Sagem Communications document. Reproduction and disclosure prohibited

6.3 - SAGEM-LINK F-H FEATURES

6.3.1 - SAGEM-LINK F-H block diagrams

The IDU-ODU interface consists of a single coaxial cable in 1+0 system. This cable transports the following frequency multiplexed signals: Uplink:

• ODU remote power supply (-48 V DC). • The modulated transmit IF signal (350 MHz) • The uplink telemetry signal consisting of a 5.5 MHz carrier amplitude modulated by a 19200 bit/s

digital signal

Downlink: • The modulated receive IF signal (140 MHz) • The downlink telemetry signal consisting of a 10 MHz carrier amplitude modulated by a 19200 bit/s

digital signal

The block diagrams of the SAGEM-LINK F-H in 1+0 and 1+1 configurations are given below.

IDU

INT4 board

TNM4 board (option)

10/100 BaseT Ethernet

MGMT1 MGMT2 Relays

µP

- 48V

Serial

MODEM

QAM Mod350 MHz

ASK Mod 19600 bit/s

5.5 MHz ASK Dem 19600

- 48 V

10 MHz

QAM Demod140 MHz

3.3V ASIC Modem

Uplink Downlink

Alarms in/out

External alarms

3 FPGA : Mux, GE, Div

16 x E1

LIU

Backplane

GigabitEthernet

Antenna

ODU

x x

3.3V

Mgt interface

48 V filtering

10/100BaseT Ethernet

Wayside

SFP SFP SFP SFP

1 to 4 GbEth

Fans

Figure 6.4 - SAGEM-LINK F-H block diagram (1+0 configuration)

Page 113: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 113/134

IDU

MainODU

StandbyODU

COUPLER

Main modem board

Standby modem board

Tx Data

Receive switch

Rx Data

Tx D

Tx D

Rx M

Rx S

Principal

Secours

Mux Demux

Giga Ethernet

E1 GE

-48V 3.3V

3.3V

-48V

SNMP interface

Gestion

PC

PC

TNM4

2 Mbit/s

Figure 6.5 - SAGEM-LINK F-H block diagram (1+1 configuration)

6.3.2 - IDU features The IDU, which is frequency independent, consists of:

• A Microprocessor controlling the system and communicating with the ODU, the remote IDU, the SNMP agent and the Pilot software.

• A Gigabit Ethernet Switch proposing up to 4 Giga Ethernet interfaces equipped with optical or electrical SFP modules

• An interface with an optional TNM4 board to propose 16 x 2 Mbit/s G703 channels; the TNM4 board acts as 2 Mbit/s line interface and tributary multiplexer / demultiplexer

• A network management interface compliant with SNMP protocol. This management interface includes 2 Ethernet ports. It communicates with the remote network management interface via an internal service channel (TSL). Once the interface has been configured, it acts as router for the network management traffic.

• An interface with 5 external alarm inputs and 3 configurable relay outputs.

• A 10/100BaseT Ethernet Wayside channel

• An RS232 interface to configure the installation

6.3.3 - Modem features The Modem, which is frequency independent, performs the following functions:

• Cable interface with the ODU. Frequency multiplexing is used to carry the following 5 signals on a coaxial cable:

- ODU power supply (-48 V)

- Transmit IF which is a QPSK 16QAM or 128QAM modulated carrier at 350 MHz frequency

- Uplink telemetry (5.5 MHz) which carries the ODU control signals

- Receive IF at 140 MHz

- Downlink telemetry (10 MHz) which carries the information returned by the ODU (in particular alarms, receive signal level).

Page 114: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 114/134 Sagem Communications document. Reproduction and disclosure prohibited

• A 350 MHz QPSK / 16QAM / 128QAM modulator including:

- A Reed Solomon error-correcting code

- A scrambler and a digital filter

- A 350 MHz I/Q modulator

• A 140 MHz QPSK / 16QAM / 128QAM demodulator including:

- Zero IF down conversion

- Adaptive equalizer

- Carrier and Clock digital recovery

- Reed Solomon ECC decoder

- Descrambler

- BER measurement device

• A DC- DC power supply, providing the tertiary voltage for the rest of the IDU (+3.3 V). In 1+1 protected systems, the unprotected part of the IDU is powered in parallel by the two power supplies from the two cable interfaces. A hot swap feature allows the modem to be plugged in and out while powered up.

6.3.4 - ODU features The ODU, which is capacity independent, is an integrated unit consisting of:

• The IDU cable Interface which is the reverse of the modem interface:

- Power supply input (-48 V)

- 350 MHz transmit IF input

- Uplink telemetry (5.5 MHz)

- 140 MHz Receive IF output

- Downlink telemetry (10 MHz)

• The transmitter which includes two frequency conversions. The frequency synthesis step is 250 kHz

• The duplexer filter

• The receiver including two frequency conversions (140 MHz IF output)

• The ODU power supply

• The microcontroller which controls the ODU and communicates with the IDU

Page 115: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 115/134

6.4 - PROTECTED CONFIGURATIONS

Three protected configurations are available: 1+1 hot standby, 1+1 space diversity and 1+1 frequency diversity.

6.4.1 - 1+1 hot standby (HSB)

INT4

Main ODU

COUPLER

Standby ODU

Main

Modem

INT4

Standby Modem

Main ODU

Standby ODU

Main

Modem

Standby Modem

COUPLER

Figure 6.6 - 1+1 hot standby configuration The 1+1 HSB configuration involves the following principles:

• The main and standby ODU operate at the same frequency and are connected to a single antenna with a coupler (6 dB or 3 dB coupling),

• When one transmitter is in traffic, the other is in mute position,

• Both receivers are operational,

• Transmitter and receiver switch controls are independent.

• The transmitter and receiver switches are controlled by the local terminal information. In normal operation, the remote terminal does not control the local terminal switch.

• Manual switching (forcing) is available via the Pilot software

• The receiver switch has a hitless feature: error-free switching under some conditions.

6.4.2 - 1+1 space diversity

INT4

Main ODU

Standby ODU

Main

Modem

INT4

Standby Modem

Main ODU

Standby ODU

Main

Modem

Standby Modem

Figure 6.7 - 1+1 space diversity configuration

1+1 space diversity is hot standby configuration, without coupler and with two antennas per terminal.

Page 116: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 116/134 Sagem Communications document. Reproduction and disclosure prohibited

6.4.3 - 1+1 frequency diversity

INT4

ODU 1

l

2 ODU

Modem

1

INT4

Modem 2

ODU1

2

ODU

Modem

1

Modem

2

F1 / F1

F2 / F2

Figure 6.8 - 1+1 frequency diversity configuration with 2 antennas per terminal

OR

INT4

ODU 1

2

ODU

ODU1

2

ODU

Modem

1

INT4

Modem 2

Fa / F'a

Fb / F'b H

V

H

V

Modem

1

Modem

2

Figure 6.9 - 1+1 frequency diversity configuration with dual polarized antenna In frequency diversity mode, there is no switching at the transmit side. The two transmitters transmit permanently at two different frequencies. Switching is carried out only on the receive data.

Page 117: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 117/134

7. GIGABIT ETHERNET FUNCTION

7.1 - S_VLAN SERVICES SAGEM-LINK F-H is used to transmit an receive Gigabit Ethernet frames to / from remote equipment. A GE Switch is implemented in the IDU in order to carry one or more VLAN transport services (S_VLAN). Each S_VLAN service routes Ethernet frames via an Ethernet bridge. Frames leaving the radio port are tagged with an S_VLAN tag according to IEE 802.1ad specification. The Switch is transparent to C_VLAN IDs. It only processes the "User Priority" field.

7.2 - PORTS

7.2.1 - Definition

The "radio port" corresponds to radio transmission between the two terminals. Since the radio transmission bandwidth is limited, this is the main point of congestion for the Ethernet transmission. The available bandwidth depends on the radio configuration (modulation, radio channel bandwidth) and the number of optional E1 channels activated. GE ports are the Gigabit Ethernet transmission accesses; they can associated with either optical interfaces (SX or LX), or electrical interfaces (10/100/1000BaseT). Electrical SFP ports can handle throughputs of 10/100/1000 Mbit/s in Full or Half duplex, except for 1000 Mbit/s which must be in Full duplex. The throughput and mode can be negotiated automatically (Auto negotiation "enable") with the remote Ethernet port.

7.2.2 - Radio port shaping

The throughput of S_VLAN data leaving the radio port can be limited by a mechanism called "Port Shaping" which ensures that the throughout does not exceed the port physical capacity. By default, Port Shaping is set to 100 % of the physical capacity but can be reduced for specific requirements.

7.2.3 - Jumbo frames

If the Ethernet frames received on the GE ports are larger than 1760 bytes, jumbo frame mode must be configured.

Page 118: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 118/134 Sagem Communications document. Reproduction and disclosure prohibited

7.3 - TOPOLOGY

Communication between ports is limited to two topologies: - "Peer to Peer" (P2P), where the Gigabit Ethernet ports #1 of each terminal are connected via a S_VLAN bridge (Virtual LAN bridge). The Gigabit Ethernet #2 port is disabled. - "Y Shape", where the two GE ports are activated, and connected to the remote terminal by the radio using S_VLAN bridges.

Data from a GE port cannot be routed locally on another GE port (implementation of PVE: Private VLAN Edge).

7.4 - CONGESTION

If the data rate from the GE ports via the radio port is greater than the rate defined by the radio Port Shaping, congestion will occur at the output resulting in data loss.

7.4.1 - Eliminating congestion

To eliminate congestion, the data rate from the GE ports can be limited by implementing a flow control mechanism. If the radio port reaches the congestion limit, the switch sends a command (pause) to the GE ports to stop data transmission; when congestion has been cleared, the switch sends a command to the GE ports to resume data transmission; the GE ports must be configured to process the pause commands.

7.4.2 - Processing congestion

7.4.2.1 Description

Two additional mechanisms are implemented to process the congestion. - Processing of alarms entering the S_VLAN service which controls the traffic according to the rate - Processing of the output frames via queues.

7.4.2.2 Traffic control

To control the traffic, a contractual data rate must be defined for each flow from a GE port entering an S_VLAN service. Note: for release R1.2, the contractual rate is defined by port, not by flow. This contractual rate (CIR: Committed Information Rate) defines the rate below which all incoming frames are guaranteed to be routed on the radio port. A metering system determines the instantaneous rate of the incoming flows. When the instantaneous rate is greater than the CIR, all frames in this flow are said to be "out of profile" and are coloured red internally. When the instantaneous flow is less than or equal to the CIR, all frames of this flow are coloured green internally. In case of congestion at output, the red frames can be deleted. This mechanism allows occasional bursts.

7.4.2.3 Output queues

A queue mechanism is used to sort the frames according to priority criteria, absorb the temporary bursts and delete the red frames in case of saturation.

Page 119: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 119/134

7.5 - QUALITY OF SERVICE (QOS)

Routing of frames from one port to another takes a certain amount of time on the transport network (S_VLAN), called latency. Depending on the data routed, this time may have to be reduced (e.g. telephone data). To perform quality of service (QoS), each frame is tagged when entering a S_VLAN service. By configuration, this priority is either allocated by default to all frames from a GE port and entering an S_VLAN service, or based on the priority which was already allocated by the equipment of the uplink customer network (User Priority - UP, contained in the Ethernet frame (802.1d)); the Switch allocates a default service priority to any frame which does not contain a UP field. QoS is managed using a mechanism involving 4 output queues (Traffic Class - TC).

- TC 0: "very low" priority; - TC 1: "low" priority; - TC 2: "high" priority; - TC 3: "very high" priority;

Queues TC0, TC1, and TC2 are WRR (Weighted Round Robin) type; these queues are emptied in turn, queues with the highest priorities first; a maximum of n frames are extracted from a TC before moving to the next one; n is known as the weight. The weights are respectively 16, 8 and 4 for TCs 2, 1 and 0. Queue TC3 is SP (Strict Priority) type; it is emptied continuously in proportion to the bandwidth allocated (very high queue priority radio bandwidth). The frames are distributed in the various queues depending on the service priority allocated to them in input. If the priority is configured globally for the entire data flow from a port and entering an S_VLAN service (Port Priority), the Switch distributes all the frames of this flow to the TC configured (Priority). If the priority used is that of the frames received (User Priority), the allocation rule is as follows: UP 0 and 3 => TC0, UP 1 and 2 => TC1, UP 4 and 5 => TC2, UP 6 and 7 => TC3, Frames with no UP field will be directed to the TC configured (Default QoS). The Switch eliminates frames according to their source or destination MAC address (black list, maximum 16 addresses). The Switch can read the statistics counters for the data passing through the port; they are classified as transmission/reception and with/without errors and can be reset for all ports at the same time. The Switch can also read the metering statistics counters; the counters record the number of bytes in green frames (rate less than or equal to the CIR) and the number of bytes in red frames (rate greater than the CIR).

Page 120: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 120/134 Sagem Communications document. Reproduction and disclosure prohibited

APPENDIX 1- SAGEM-LINK F-H SPECIFICATIONS

General characteristics

Versions and configurations Frequency bands 6L, 6H, 7, 8, 11, 13, 15, 18, 23, 26, 32, 38 GHz

Bitrates Giga Ethernet 1000BaseSX, 1000BaseLX, 10/100/1000BaseT 10/100BaseT Ethernet 0, 2, 4 8 or 16 x 2 Mbit/s

Protection 1+0 Unprotected 1+1 Hot standby (HSB) 1+1 Space or frequency diversity

Applicable ETSI standards All bands EN 302 217

Frequency bands 6 GHz (6L) 6 GHz (6H) 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 32 GHz 38 GHz

5.9 GHz - 6.4 GHz 6.4 GHz - 7.1 GHz 7.1 GHz - 7.7GHz 7.7 GHz - 8.5 GHz 10.7 GHz - 11.7 GHz 12.75 GHz - 13.25 GHz 14.4 GHz - 15.35 GHz 17.7 GHz - 19.7 GHz 21.2 GHz - 23.6 GHz 24.5 GHz - 26.5 GHz 31.8 GHz - 33.4 GHz 37 GHz - 39.5 GHz

Duplex spacing 6 GHz (6L) 6 GHz (6H) 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 32 GHz 38 GHz

240, 252.04 MHz 340 MHz 154, 160, 161, 168, 196, 245 MHz, 119, 126, 151.614, 208, 266, 311.32 MHz 490, 500, 530 MHz 266 MHz 315, 420, 475, 490, 640, 644, 728 MHz 1010, 1560 MHz 1008, 1200, 1232 MHz 800, 1008 MHz 812 MHz 700, 1260 MHz

Modulation QPSK, 16QAM, 128QAM

Tx-Tx spacing 28 MHz, 56 MHz

Error-correcting code Reed Solomon With or without interleaver (software control)

Frequency agility see APPENDIX 3 and § 6.2.5 -

Page 121: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 121/134

Transmission characteristics

Output power

Measured at ODU Output Tolerance ± 2 dB (±1.5 dB at Pmax)

QPSK 16QAM 128QAM

6, 7, 8 GHz 30 dBm 28 dBm 24 dBm11 GHz 28 dBm 26 dBm 21 dBm13, 15 GHz 26 dBm 23 dBm 18 dBm18 GHz 25.5 dBm 22 dBm 17 dBm23, 26 GHz 25 dBm 22 dBm 17 dBm32 GHz 23 dBm 21 dBm 16 dBm38 GHz 23 dBm 20 dBm 16 dBm Minimum power 6, 7, 8 GHz 9 dBm 9 dBm 9 dBm11 GHz 6 dBm 6 dBm 6 dBm13, 15 GHz 3 dBm 3 dBm 3 dBm18, 23, 26 GHz 2 dBm 2 dBm 2 dBm32, 38 GHz 1 dBm 1 dBm 1 dBm Power step 0.5 dB 0.5 dB 0.5 dB Automatic Tx Power Control (ATPC algorithm)

Dynamic range 15 dB max* 15 dB max* 15 dB max* Output power with Transmit Mute

<-50 dBm <-50 dBm <-50 dBm

Frequency step 250 kHz 250 kHz 250 kHz

Frequency stability ± 10 ppm ± 10 ppm ± 10 ppm (*) Note: Within ODU transmit power range (Max Power – Min Power)

Page 122: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 122/134 Sagem Communications document. Reproduction and disclosure prohibited

Reception characteristics

Maximum non destructive level at ODU input -10 dBm Maximum level for BER < 10-6 -22 dBm Reception thresholds for BER < 10-6 1+0, 1+1 SD, 1+1 FD, ODU access

28 MHz radio channel 56 MHz radio channel

6, 7, 8, 11, 13, 15, 18, 23, 26 GHz

-69 dBm -66 dBm

32 GHz -68 dBm -65 dBm 38 GHz -67 dBm -64 dBm 1+1 coupler losses - 3 dB (channel 1/channel 2) 3.5 dB / 3.5 dB

1+1 coupler losses - 6 dB (channel 1/channel 2) 2 dB / 6.5 dB

Residual error rate < 10-12 when RSL is between 10 and 35 dB above the threshold at 10-6 (EN 302 217

2-1 - §6.5.1)

Analog RSSI voltage (ODU BNC connector) 4.5 V at –20 dBm; 0.1 V at –90 dBm, monotone curve Variation law: RSL (dBm) = 15.77 VBNC-91.58

RSSI voltage accuracy ± 3 dB RSL indication accuracy (from the Pilot) ± 3 dB

Gigabit Ethernet / 2 Mbit/s access Giga Ethernet 1 to 2 GE, 1000BaseSX optical SFP, 1000BaseLX, 10/100/1000BaseT electrical SFP 2 Mbit/s 0, 2, 4, 8 or 16x2 Mbit/s / 120 Ω or 75 Ω - IUT-R G. 703 2xDB44

Wayside and network management interfaces

Alarm relays (outputs) 3 DB15 HD External alarms (inputs) 5 “ Wayside 10/100BaseT Ethernet interface RJ45 VT100 interface PC access RS232 DB9

Network management interfaces 2 x 10/100BaseT Ethernet interfaces 2xRJ45 Integrated hub

Page 123: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 123/134

Mechanical characteristics

Dimensions Station chassis (IDU) 1U, 19-inch: 44(H) x 485 (L) x 300 (D) mm

Radio box (ODU) Diameter: 267 mm, depth: 89 mm

Weight Station chassis (IDU) 5 kg (1+0) 5.5 kg (1+1) Radio box (ODU) 5 kg Installation Station chassis (IDU) 19-inch rack Radio box (ODU) 50 to 115 mm diameter poles IDU-ODU interconnection 1+0 1 coaxial cable 1+1 2 coaxial cables Impedance 50 Ω Length Up to 600 m depending on cable type

Examples Type RG8/U (3/8") < 230 m

Type RG8/X (1/4") < 80 m

Andrew LDF4-50A < 600 m

Power consumption

Input voltage -39 V to -59 V

Power consumption 1+0 configuration 1+1 configuration

IDU ≤ 45 W (typical 40 W) ODU ≤ 52 W (typical 45 W) IDU ≤ 70 W (typical 65 W)

Environmental characteristics

Environmental conditions IDU

ODU EN 300 019-1-3 class 3.1 EN 300 019-1-4 class 4.1

Temperature range IDU -5°C to +45°C ODU -33 °C to +55°C

Storage conditions (equipment packed)

EN 300 019-1-1 class 1.1

Transport conditions (equipment packed)

EN 300 019-1-2 class 2.3

Electromagnetic compatibility EN 301 489-1/4

Page 124: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 124/134 Sagem Communications document. Reproduction and disclosure prohibited

APPENDIX 2 - GIGABIT ETHERNET ACCESS SPECIFICATIONS

Gigabit Ethernet throughput without QoS Frame size (bytes)

Throughput

64 128 256 512 1024 1280 1518 1760

128 QAM 56MHz 0E1 353Mbps 320Mbps 303Mbps 294Mbps 290Mbps 289Mbps 289Mbps 288Mbps 128 QAM 56MHz 4E1 341Mbps 310Mbps 294Mbps 285Mbps 281Mbps 280Mbps 280Mbps 279Mbps 128 QAM 56MHz 8E1 330Mbps 300Mbps 285Mbps 276Mbps 273Mbps 272Mbps 271Mbps 271Mbps 128 QAM 56MHz 16E1 308Mbps 280Mbps 266Mbps 259Mbps 255Mbps 254Mbps 253Mbps 253Mbps 128 QAM 28MHz 0E1 186Mbps 169Mbps 160Mbps 156Mbps 153Mbps 153Mbps 153Mbps 152Mbps 128 QAM 28MHz 2E1 181Mbps 164Mbps 155Mbps 151Mbps 147Mbps 148Mbps 148Mbps 148Mbps 128 QAM 28MHz 4E1 176Mbps 160Mbps 151Mbps 147Mbps 144Mbps 144Mbps 144Mbps 144Mbps 128 QAM 28MHz 8E1 165Mbps 150Mbps 142Mbps 138Mbps 136Mbps 135Mbps 135Mbps 135Mbps 128 QAM 28MHz 16E1 144Mbps 131Mbps 124Mbps 120Mbps 118Mbps 118Mbps 118Mbps 118Mbps 16 QAM 56MHz 0E1 203Mbps 185Mbps 175Mbps 170Mbps 167Mbps 167Mbps 167Mbps 166Mbps 16 QAM 56MHz 2E1 198Mbps 180Mbps 170Mbps 165Mbps 163Mbps 163Mbps 162Mbps 162Mbps 16 QAM 56MHz 4E1 193Mbps 175Mbps 166Mbps 161Mbps 159Mbps 158Mbps 158Mbps 158Mbps 16 QAM 56MHz 8E1 182Mbps 165Mbps 157Mbps 152Mbps 150Mbps 150Mbps 149Mbps 149Mbps 16 QAM 56MHz 16E1 161Mbps 146Mbps 139Mbps 135Mbps 132Mbps 132Mbps 132Mbps 132Mbps 16 QAM 28MHz 0E1 106Mbps 97Mbps 91Mbps 89Mbps 87Mbps 87Mbps 87Mbps 87Mbps 16 QAM 28MHz 2E1 101Mbps 91Mbps 87Mbps 85Mbps 83Mbps 83Mbps 82Mbps 82Mbps 16 QAM 28MHz 4E1 96Mbps 87Mbps 82Mbps 80Mbps 79Mbps 78Mbps 78Mbps 78Mbps 16 QAM 28MHz 8E1 85Mbps 78Mbps 73Mbps 71Mbps 70Mbps 70Mbps 70Mbps 70Mbps 16 QAM 28MHz 16E1 64Mbps 58Mbps 55Mbps 53Mbps 52Mbps 52Mbps 52Mbps 52Mbps QPSK 56MHz 0E1 100Mbps 91Mbps 86Mbps 84Mbps 83Mbps 82Mbps 82Mbps 82Mbps QPSK 56MHz 2E1 95Mbps 86Mbps 82Mbps 79Mbps 78Mbps 78Mbps 78Mbps 77Mbps QPSK 56MHz 4E1 90Mbps 81Mbps 77Mbps 75Mbps 74Mbps 73Mbps 73Mbps 73Mbps QPSK 56MHz 8E1 79Mbps 72Mbps 68Mbps 66Mbps 65Mbps 65Mbps 65Mbps 65Mbps QPSK 56MHz 16E1 57Mbps 51Mbps 47Mbps 45Mbps 45Mbps 45Mbps 44Mbps 43Mbps QPSK 28MHz 0E1 52Mbps 47Mbps 44Mbps 43Mbps 42Mbps 42Mbps 42Mbps 41Mbps QPSK 28MHz 2E1 46Mbps 41Mbps 38Mbps 36Mbps 36Mbps 36Mbps 35Mbps 35Mbps QPSK 28MHz 4E1 40Mbps 36Mbps 33Mbps 32Mbps 32Mbps 31Mbps 31Mbps 30Mbps QPSK 28MHz 8E1 30Mbps 27Mbps 25Mbps 24Mbps 23Mbps 23Mbps 23Mbps 23Mbps QPSK 28MHz 16E1 10Mbps 8Mbps 8Mbps 8Mbps 8Mbps 8Mbps 8Mbps 8Mbps

Page 125: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 125/134

Gigabit Ethernet throughput with QoS Frame size (bytes)

Throughput 64 128 256 512 1024 1280 1518 1760 128 QAM 56MHz 0E1 350Mbps 309Mbps 288Mbps 278Mbps 273Mbps 272Mbps 271Mbps 270Mbps 128 QAM 56MHz 4E1 338Mbps 299Mbps 279Mbps 270Mbps 264Mbps 264Mbps 264Mbps 263Mbps 128 QAM 56MHz 8E1 330Mbps 291Mbps 271Mbps 261Mbps 256Mbps 255Mbps 255Mbps 254Mbps 128 QAM 56MHz 16E1 308Mbps 271Mbps 254Mbps 244Mbps 239Mbps 238Mbps 238Mbps 238Mbps 128 QAM 28MHz 0E1 185Mbps 163Mbps 152Mbps 147Mbps 144Mbps 144Mbps 143Mbps 143Mbps 128 QAM 28MHz 2E1 180Mbps 159Mbps 148Mbps 143Mbps 140Mbps 139Mbps 139Mbps 139Mbps 128 QAM 28MHz 4E1 174Mbps 154Mbps 144Mbps 138Mbps 136Mbps 135Mbps 135Mbps 135Mbps 128 QAM 28MHz 8E1 164Mbps 145Mbps 135Mbps 130Mbps 128Mbps 127Mbps 127Mbps 127Mbps 128 QAM 28MHz 16E1 143Mbps 126Mbps 118Mbps 114Mbps 111Mbps 111Mbps 111Mbps 110Mbps 16 QAM 56MHz 0E1 202Mbps 178Mbps 166Mbps 160Mbps 157Mbps 157Mbps 156Mbps 156Mbps 16 QAM 56MHz 2E1 198Mbps 174Mbps 162Mbps 156Mbps 153Mbps 153Mbps 152Mbps 152Mbps 16 QAM 56MHz 4E1 192Mbps 169Mbps 158Mbps 152Mbps 149Mbps 149Mbps 148Mbps 148Mbps 16 QAM 56MHz 8E1 181Mbps 160Mbps 149Mbps 144Mbps 141Mbps 141Mbps 140Mbps 140Mbps 16 QAM 56MHz 16E1 160Mbps 141Mbps 132Mbps 127Mbps 125Mbps 124Mbps 124Mbps 124Mbps 16 QAM 28MHz 0E1 105Mbps 93Mbps 87Mbps 83Mbps 82Mbps 82Mbps 81Mbps 81Mbps 16 QAM 28MHz 2E1 100Mbps 88Mbps 82Mbps 80Mbps 78Mbps 77Mbps 77Mbps 77Mbps 16 QAM 28MHz 4E1 95Mbps 84Mbps 78Mbps 75Mbps 74Mbps 74Mbps 74Mbps 73Mbps 16 QAM 28MHz 8E1 84Mbps 75Mbps 69Mbps 67Mbps 66Mbps 66Mbps 66Mbps 65Mbps 16 QAM 28MHz 16E1 63Mbps 56Mbps 52Mbps 50Mbps 49Mbps 49Mbps 49Mbps 49Mbps QPSK 56MHz 0E1 99Mbps 88Mbps 82Mbps 79Mbps 77Mbps 77Mbps 77Mbps 76Mbps QPSK 56MHz 2E1 94Mbps 83Mbps 77Mbps 75Mbps 73Mbps 73Mbps 73Mbps 73Mbps QPSK 56MHz 4E1 89Mbps 79Mbps 73Mbps 71Mbps 69Mbps 69Mbps 69Mbps 69Mbps QPSK 56MHz 8E1 79Mbps 70Mbps 65Mbps 62Mbps 61Mbps 61Mbps 61Mbps 61Mbps QPSK 56MHz 16E1 57Mbps 51Mbps 47Mbps 45Mbps 45Mbps 45Mbps 44Mbps 43Mbps QPSK 28MHz 0E1 51Mbps 45Mbps 42Mbps 41Mbps 40Mbps 40Mbps 39Mbps 39Mbps QPSK 28MHz 2E1 46Mbps 41Mbps 38Mbps 36Mbps 36Mbps 36Mbps 35Mbps 35Mbps QPSK 28MHz 4E1 40Mbps 36Mbps 33Mbps 32Mbps 32Mbps 31Mbps 31Mbps 30Mbps QPSK 28MHz 8E1 30Mbps 27Mbps 25Mbps 24Mbps 23Mbps 23Mbps 23Mbps 23Mbps QPSK 28MHz 16E1 9Mbps 8Mbps 7Mbps 7Mbps 7Mbps 7Mbps 7Mbps 7Mbps

Page 126: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 126/134 Sagem Communications document. Reproduction and disclosure prohibited

Latency depending on the configuration Frame size (bytes)

Throughput 64 128 256 512 1024 1280 1518 1760 128 QAM 56MHz 0E1 83µs 86µs 93µs 106µs 132µs 145µs 158µs 171µs 128 QAM 56MHz 4E1 83µs 86µs 93µs 106µs 132µs 145µs 158µs 171µs 128 QAM 56MHz 8E1 83µs 86µs 93µs 106.5µs 134µs 147µs 161µs 174µs 128 QAM 56MHz 16E1 84µs 88µs 95µs 109µs 138µs 152µs 165µs 179µs 128 QAM 28MHz 0E1 148µs 153µs 163µs 182µs 222µs 242µs 260µs 278µs 128 QAM 28MHz 2E1 148µs 153µs 163µs 182µs 222µs 242µs 260µs 278µs 128 QAM 28MHz 4E1 148µs 153µs 163µs 183µs 224µs 244µs 264µs 284µs 128 QAM 28MHz 8E1 149µs 154µs 165µs 186µs 229µs 250µs 270µs 290µs 128 QAM 28MHz 16E1 150µs 155µs 167µs 190µs 238µs 262µs 285µs 305µs 16 QAM 56MHz 0E1 124µs 128µs 138µs 157µs 194µs 212µs 229µs 247µs 16 QAM 56MHz 2E1 124µs 129µs 139µs 158µs 195µs 214µs 231µs 248µs 16 QAM 56MHz 4E1 125µs 129µs 139µs 158µs 197µs 216µs 234µs 252µs 16 QAM 56MHz 8E1 125µs 131µs 140µs 160µs 199µs 219µs 238µs 256µs 16 QAM 56MHz 16E1 125µs 132µs 142µs 164µs 208µs 229µs 247µs 268µs 16 QAM 28MHz 0E1 227µs 234µs 249µs 278µs 338µs 367µs 395µs 424µs 16 QAM 28MHz 2E1 228µs 236µs 252µs 283µs 346µs 377µs 405µs 435µs 16 QAM 28MHz 4E1 229µs 239µs 254µs 286µs 352µs 383µs 414µs 445µs 16 QAM 28MHz 8E1 232µs 239µs 256µs 292µs 363µs 398µs 431µs 465µs 16 QAM 28MHz 16E1 237µs 247µs 270µs 316µs 406µs 450µs 492µs 543µs QPSK 56MHz 0E1 242µs 250µs 265µs 297µs 359µs 390µs 419µs 449µs QPSK 56MHz 2E1 242µs 250µs 267µs 299µs 365µs 397µs 427µs 458µs QPSK 56MHz 4E1 244µs 252µs 270µs 303µs 370µs 405µs 440µs 470µs QPSK 56MHz 8E1 246µs 256µs 274µs 312µs 388µs 426µs 461µs 497µs QPSK 56MHz 16E1 254µs 264µs 288µs 335µs 430µs 474µs 522µs 560µs QPSK 28MHz 0E1 439µs 452µs 480µs 534µs 643µs 698µs 748µs 800µs QPSK 28MHz 2E1 452µs 468µs 498µs 557µs 678µs 738µs 794µs 852µs QPSK 28MHz 4E1 437µs 456µs 487µs 555µs 689µs 755µs 816µs 881µs QPSK 28MHz 8E1 463µs 481µs 524µs 610µs 782µs 867µs 941µs 1023µs QPSK 28MHz 16E1 572µs 623µs 754µs 1017µs 1541µs 1804µs 2060µs 2289µs Note: These measurements were made with the data interleaver deactivated (default configuration). These values correspond to a one way link : if a loopback is used to perform the measurement, the corresponding latency should be the double of the above figures.

Page 127: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 127/134

APPENDIX 3 - SAGEM-LINK F-H REFERENCES

Link composition Depending on the configuration, a SAGEM-LINK F-H link is composed of the following items:

ODU IDU HB LB Modem GE E1 Fan

SAGEM-LINK F-H Reference

UH

Hxx

UH

Bxx

UFC

_HW

UFX

_SP

UFE

-16E

1

UFF

UFD

xxC

6 (C

oupl

er)

GE UFHL-bb-S0N-cccc-dd 2 2 2 2 2 1+0

GE + 16 E1 UFHL-bb-S1N-cccc-dd 2 2 2 2 2 2

GE UFHL-bb-S0H-cccc-dd 4 4 4 2 2 1+1 HSB with

coupler GE + 16 E1 UFHL-bb-S1H-cccc-dd 4 4 4 2 2

GE UFHL-bb-S0S-cccc-dd 4 4 4 2 1+1 SD (2 antennas) GE + 16 E1 UFHL-bb-S1S-cccc-dd 4 4 4 2

GE UFHL-bb-S0F-cccc-dd-ff 4 4 4 2 1+1 FD (2 antennas) GE + 16 E1 UFHL-bb-S1F-cccc-dd-ff 4 4 4 2 2

UFHL-bb-XYZ-cccc-dd-ff

bb Frequency Band (GHz) 06, 07, 08, 11,13, 15, 18, 23, 26, 32, 38X S : without XPIC, H: with XPIC Y O : without E1, 1: with 16 E1s

Z N : 1+0, H : 1+1 HSB, S : 1+1 SD, F : 1+1 FD

cccc Duplex spacing (MHz) dd Sub-band 01, 02,… ff Sub-band channel 2 (frequency diversity) 01, 02,…

Page 128: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 128/134 Sagem Communications document. Reproduction and disclosure prohibited

References of SAGEM-LINK F-H ODUs

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

6 GHz ODUs UHB06-A240-01-00 253086728 ODU SLH 06GHZ TR A240 LO B1 5 925,0 6 025,0 240 UHH06-A240-01-00 253086749 ODU SLH 06GHZ TR A240 HI B1 6 175,0 6 275,0 240 UHB06-A240-02-00 253086757 ODU SLH 06GHZ TR A240 LO B2 6 000,0 6 100,0 240 UHH06-A240-02-00 253086760 ODU SLH 06GHZ TR A240 HI B2 6 250,0 6 350,0 240 UHB06-A240-03-00 253086778 ODU SLH 06GHZ TR A240 LO B3 6 075,0 6 175,0 240 UHH06-A240-03-00 253086781 ODU SLH 06GHZ TR A240 HI B3 6 325,0 6 425,0 240 UHB06-A252-01-00 253086799 ODU SLH 06GHZ TR A252 LO B1 5 925,0 6 025,0 252 UHH06-A252-01-00 253086801 ODU SLH 06GHZ TR A252 HI B1 6 175,0 6 275,0 252 UHB06-A252-02-00 253086822 ODU SLH 06GHZ TR A252 LO B2 6 000,0 6 100,0 252 UHH06-A252-02-00 253086830 ODU SLH 06GHZ TR A252 HI B2 6 250,0 6 350,0 252 UHB06-A252-03-00 253086851 ODU SLH 06GHZ TR A252 LO B3 6 075,0 6 175,0 252 UHH06-A252-03-00 253086864 ODU SLH 06GHZ TR A252 HI B3 6 325,0 6 425,0 252 UHB06-A340-01-00 253086872 ODU SLH 06GHZ TR A340 LO B1 6 430,0 6 540,0 340 UHH06-A340-01-00 253086885 ODU SLH 06GHZ TR A340 HI B1 6 770,0 6 880,0 340 UHB06-A340-02-00 253086893 ODU SLH 06GHZ TR A340 LO B2 6 520,0 6 630,0 340 UHH06-A340-02-00 253086939 ODU SLH 06GHZ TR A340 HI B2 6 860,0 6 970,0 340 UHB06-A340-03-00 253086947 ODU SLH 06GHZ TR A340 LO B3 6 600,0 6 710,0 340 UHH06-A340-03-00 253086950 ODU SLH 06GHZ TR A340 HI B3 6 940,0 7 050,0 340 UHB06-A340-04-00 253086968 ODU SLH 06GHZ TR A340 LO B4 6 670,0 6 780,0 340 UHH06-A340-04-00 253086971 ODU SLH 06GHZ TR A340 HI B4 7 010,0 7 120,0 340

7 GHz ODUs UHB07-A154-01-00 252957519 ODU SLH 07GHZ TR A154 LO B1 7 428,0 7 484,0 154 UHH07-A154-01-00 252957527 ODU SLH 07GHZ TR A154 HI B1 7 582,0 7 638,0 154 UHB07-A154-02-00 252957530 ODU SLH 07GHZ TR A154 LO B2 7 470,0 7 526,0 154 UHH07-A154-02-00 252957548 ODU SLH 07GHZ TR A154 HI B2 7 624,0 7 680,0 154 UHB07-A154-03-00 252957551 ODU SLH 07GHZ TR A154 LO B3 7 512,0 7 568,0 154 UHH07-A154-03-00 252957569 ODU SLH 07GHZ TR A154 HI B3 7 666,0 7 722,0 154 UHB07-A160-01-00 252957572 ODU SLH 07GHZ TR A160 LO B1 7 433,5 7 496,5 160 UHH07-A160-01-00 252957580 ODU SLH 07GHZ TR A160 HI B1 7 593,5 7 656,5 160 UHB07-A160-02-00 252957593 ODU SLH 07GHZ TR A160 LO B2 7 478,5 7 541,5 160 UHH07-A160-02-00 252957605 ODU SLH 07GHZ TR A160 HI B2 7 638,5 7 701,5 160 UHB07-A160-03-00 252957613 ODU SLH 07GHZ TR A160 LO B3 7 526,0 7 589,0 160 UHH07-A160-03-00 252957626 ODU SLH 07GHZ TR A160 HI B3 7 686,0 7 749,0 160 UHB07-A161-01-00 252957634 ODU SLH 07GHZ TR A161 LO B1 7 117,0 7 180,0 161 UHH07-A161-01-00 252957647 ODU SLH 07GHZ TR A161 HI B1 7 278,0 7 341,0 161 UHB07-A161-02-00 252957655 ODU SLH 07GHZ TR A161 LO B2 7 159,0 7 222,0 161 UHH07-A161-02-00 252957668 ODU SLH 07GHZ TR A161 HI B2 7 320,0 7 383,0 161 UHB07-A161-03-00 252957676 ODU SLH 07GHZ TR A161 LO B3 7 198,0 7 261,0 161 UHH07-A161-03-00 252957689 ODU SLH 07GHZ TR A161 HI B3 7 359,0 7 422,0 161 UHB07-A161-04-00 252957697 ODU SLH 07GHZ TR A161 LO B4 7 213,0 7 276,0 161 UHH07-A161-04-00 252957709 ODU SLH 07GHZ TR A161 HI B4 7 374,0 7 437,0 161 UHB07-B161-01-00 252957717 ODU SLH 07GHZ TR B161 LO B1 7 417,0 7 480,0 161 UHH07-B161-01-00 252957720 ODU SLH 07GHZ TR B161 HI B1 7 578,0 7 641,0 161 UHB07-B161-02-00 252957738 ODU SLH 07GHZ TR B161 LO B2 7 459,0 7 522,0 161 UHH07-B161-02-00 252957741 ODU SLH 07GHZ TR B161 HI B2 7 620,0 7 683,0 161

Page 129: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 129/134

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

UHB07-B161-03-00 252957759 ODU SLH 07GHZ TR B161 LO B3 7 498,0 7 561,0 161 UHH07-B161-03-00 252957762 ODU SLH 07GHZ TR B161 HI B3 7 659,0 7 722,0 161 UHB07-B161-04-00 252957770 ODU SLH 07GHZ TR B161 LO B4 7 513,0 7 576,0 161 UHH07-B161-04-00 252957783 ODU SLH 07GHZ TR B161 HI B4 7 674,0 7 737,0 161 UHB07-C161-01-00 253086989 ODU SLH 07GHZ TR C161 LO B1 7 114,0 7 177,0 161 UHH07-C161-01-00 253086992 ODU SLH 07GHZ TR C161 HI B1 7 275,0 7 338,0 161 UHB07-C161-02-00 253087001 ODU SLH 07GHZ TR C161 LO B2 7 149,0 7 212,0 161 UHH07-C161-02-00 253087019 ODU SLH 07GHZ TR C161 HI B2 7 310,0 7 373,0 161 UHB07-C161-03-00 253087022 ODU SLH 07GHZ TR C161 LO B3 7 184,0 7 247,0 161 UHH07-C161-03-00 253087030 ODU SLH 07GHZ TR C161 HI B3 7 345,0 7 408,0 161 UHB07-C161-04-00 253087043 ODU SLH 07GHZ TR C161 LO B4 7 219,0 7 282,0 161 UHH07-C161-04-00 253087051 ODU SLH 07GHZ TR C161 HI B4 7 380,0 7 443,0 161 UHB07-D161-01-00 253087064 ODU SLH 07GHZ TR D161 LO B1 7 239,0 7 302,0 161 UHH07-D161-01-00 253087072 ODU SLH 07GHZ TR D161 HI B1 7 400,0 7 463,0 161 UHB07-D161-02-00 253087085 ODU SLH 07GHZ TR D161 LO B2 7 274,0 7 337,0 161 UHH07-D161-02-00 253087105 ODU SLH 07GHZ TR D161 HI B2 7 435,0 7 498,0 161 UHB07-D161-03-00 253087118 ODU SLH 07GHZ TR D161 LO B3 7 309,0 7 372,0 161 UHH07-D161-03-00 253087147 ODU SLH 07GHZ TR D161 HI B3 7 470,0 7 533,0 161 UHB07-D161-04-00 253087150 ODU SLH 07GHZ TR D161 LO B4 7 344,0 7 407,0 161 UHH07-D161-04-00 253087168 ODU SLH 07GHZ TR D161 HI B4 7 505,0 7 568,0 161 UHB07-E161-01-00 253087171 ODU SLH 07GHZ TR E161 LO B1 7 414,0 7 477,0 161 UHH07-E161-01-00 253087192 ODU SLH 07GHZ TR E161 HI B1 7 575,0 7 638,0 161 UHB07-E161-02-00 253087209 ODU SLH 07GHZ TR E161 LO B2 7 449,0 7 512,0 161 UHH07-E161-02-00 253087212 ODU SLH 07GHZ TR E161 HI B2 7 610,0 7 673,0 161 UHB07-E161-03-00 253087220 ODU SLH 07GHZ TR E161 LO B3 7 484,0 7 547,0 161 UHH07-E161-03-00 253087233 ODU SLH 07GHZ TR E161 HI B3 7 645,0 7 708,0 161 UHB07-E161-04-00 253087241 ODU SLH 07GHZ TR E161 LO B4 7 519,0 7 582,0 161 UHH07-E161-04-00 253087254 ODU SLH 07GHZ TR E161 HI B4 7 680,0 7 743,0 161 UHB07-F161-01-00 253087262 ODU SLH 07GHZ TR F161 LO B1 7 539,0 7 602,0 161 UHH07-F161-01-00 253087275 ODU SLH 07GHZ TR F161 HI B1 7 700,0 7 763,0 161 UHB07-F161-02-00 253087283 ODU SLH 07GHZ TR F161 LO B2 7 574,0 7 637,0 161 UHH07-F161-02-00 253087308 ODU SLH 07GHZ TR F161 HI B2 7 735,0 7 798,0 161 UHB07-F161-03-00 253087329 ODU SLH 07GHZ TR F161 LO B3 7 609,0 7 672,0 161 UHH07-F161-03-00 253087337 ODU SLH 07GHZ TR F161 HI B3 7 770,0 7 833,0 161 UHB07-F161-04-00 253087340 ODU SLH 07GHZ TR F161 LO B4 7 644,0 7 707,0 161 UHH07-F161-04-00 253087358 ODU SLH 07GHZ TR F161 HI B4 7 805,0 7 868,0 161 UHB07-A168-01-00 252957791 ODU SLH 07GHZ TR A168 LO B1 7 443,0 7 499,0 168 UHH07-A168-01-00 252957803 ODU SLH 07GHZ TR A168 HI B1 7 611,0 7 667,0 168 UHB07-A168-02-00 252957816 ODU SLH 07GHZ TR A168 LO B2 7 485,0 7 541,0 168 UHH07-A168-02-00 252957824 ODU SLH 07GHZ TR A168 HI B2 7 653,0 7 709,0 168 UHB07-A168-03-00 252957837 ODU SLH 07GHZ TR A168 LO B3 7 527,0 7 583,0 168 UHH07-A168-03-00 252957845 ODU SLH 07GHZ TR A168 HI B3 7 695,0 7 751,0 168 UHB07-A196-01-00 253087382 ODU SLH 07GHZ TR A196 LO B1 7 093,0 7 149,0 196 UHH07-A196-01-00 253087390 ODU SLH 07GHZ TR A196 HI B1 7 289,0 7 345,0 196 UHB07-A196-02-00 253087402 ODU SLH 07GHZ TR A196 LO B2 7 121,0 7 177,0 196 UHH07-A196-02-00 253087410 ODU SLH 07GHZ TR A196 HI B2 7 317,0 7 373,0 196 UHB07-A196-03-00 253087423 ODU SLH 07GHZ TR A196 LO B3 7 149,0 7 205,0 196 UHH07-A196-03-00 253087431 ODU SLH 07GHZ TR A196 HI B3 7 345,0 7 401,0 196 UHB07-A196-04-00 253087444 ODU SLH 07GHZ TR A196 LO B4 7 177,0 7 233,0 196 UHH07-A196-04-00 253087452 ODU SLH 07GHZ TR A196 HI B4 7 373,0 7 429,0 196 UHB07-A196-05-00 253087465 ODU SLH 07GHZ TR A196 LO B5 7 205,0 7 261,0 196 UHH07-A196-05-00 253087473 ODU SLH 07GHZ TR A196 HI B5 7 401,0 7 457,0 196 UHB07-A245-01-00 253087486 ODU SLH 07GHZ TR A245 LO B1 7 400,0 7 484,0 245

Page 130: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 130/134 Sagem Communications document. Reproduction and disclosure prohibited

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

UHH07-A245-01-00 253087506 ODU SLH 07GHZ TR A245 HI B1 7 645,0 7 729,0 245 UHB07-A245-02-00 253087527 ODU SLH 07GHZ TR A245 LO B2 7 484,0 7 568,0 245 UHH07-A245-02-00 253087548 ODU SLH 07GHZ TR A245 HI B2 7 729,0 7 813,0 245 UHB07-A245-03-00 253087569 ODU SLH 07GHZ TR A245 LO B3 7 568,0 7 652,0 245 UHH07-A245-03-00 253087572 ODU SLH 07GHZ TR A245 HI B3 7 813,0 7 897,0 245

8 GHz ODUs

UHB08-A126-01-00 252957879 ODU SLH 08GHZ TR A126 LO B1 8 279,0 8 307,0 119 & 126 UHH08-A126-01-00 252957887 ODU SLH 08GHZ TR A126 HI B1 8 398,0 8 426,0 119 & 126 UHB08-A126-02-00 252957890 ODU SLH 08GHZ TR A126 LO B2 8 293,0 8 321,0 119 & 126 UHH08-A126-02-00 252957907 ODU SLH 08GHZ TR A126 HI B2 8 412,0 8 440,0 119 & 126 UHB08-A126-03-00 252957910 ODU SLH 08GHZ TR A126 LO B3 8 307,0 8 335,0 119 & 126 UHH08-A126-03-00 252957928 ODU SLH 08GHZ TR A126 HI B3 8 426,0 8 454,0 119 & 126 UHB08-A126-04-00 252957931 ODU SLH 08GHZ TR A126 LO B4 8 321,0 8 349,0 119 & 126 UHH08-A126-04-00 252957949 ODU SLH 08GHZ TR A126 HI B4 8 440,0 8 468,0 119 & 126 UHB08-A126-05-00 252957952 ODU SLH 08GHZ TR A126 LO B5 8 335,0 8 363,0 119 & 126 UHH08-A126-05-00 252957960 ODU SLH 08GHZ TR A126 HI B5 8 454,0 8 482,0 119 & 126 UHB08-A126-06-00 252957973 ODU SLH 08GHZ TR A126 LO B6 8 349,0 8 377,0 119 & 126 UHH08-A126-06-00 252957981 ODU SLH 08GHZ TR A126 HI B6 8 468,0 8 496,0 119 & 126 UHB08-A151-01-00 252957994 ODU SLH 08GHZ TR A151 LO B1 8 203,0 8 271,0 151 UHH08-A151-01-00 252958003 ODU SLH 08GHZ TR A151 HI B1 8 355,0 8 423,0 151 UHB08-A151-02-00 252958016 ODU SLH 08GHZ TR A151 LO B2 8 240,0 8 308,0 151 UHH08-A151-02-00 252958024 ODU SLH 08GHZ TR A151 HI B2 8 392,0 8 460,0 151 UHB08-A151-03-00 252958037 ODU SLH 08GHZ TR A151 LO B3 8 277,0 8 345,0 151 UHH08-A151-03-00 252958045 ODU SLH 08GHZ TR A151 HI B3 8 429,0 8 497,0 151 UHB08-A208-01-00 252958058 ODU SLH 08GHZ TR A208 LO B1 8 043,0 8 113,0 208 UHH08-A208-01-00 252958066 ODU SLH 08GHZ TR A208 HI B1 8 251,0 8 321,0 208 UHB08-A208-02-00 252958079 ODU SLH 08GHZ TR A208 LO B2 8 099,0 8 169,0 208 UHH08-A208-02-00 252958087 ODU SLH 08GHZ TR A208 HI B2 8 307,0 8 377,0 208 UHB08-A208-03-00 252958090 ODU SLH 08GHZ TR A208 LO B3 8 155,0 8 225,0 208 UHH08-A208-03-00 252958107 ODU SLH 08GHZ TR A208 HI B3 8 363,0 8 433,0 208 UHB08-A208-04-00 252958110 ODU SLH 08GHZ TR A208 LO B4 8 211,0 8 281,0 208 UHH08-A208-04-00 252958128 ODU SLH 08GHZ TR A208 HI B4 8 419,0 8 489,0 208 UHB08-A266-01-00 252958131 ODU SLH 08GHZ TR A266 LO B1 7 905,0 8 024,0 266 UHH08-A266-01-00 252958149 ODU SLH 08GHZ TR A266 HI B1 8 171,0 8 290,0 266 UHB08-A266-02-00 252958152 ODU SLH 08GHZ TR A266 LO B2 8 017,0 8 136,0 266 UHH08-A266-02-00 252958160 ODU SLH 08GHZ TR A266 HI B2 8 283,0 8 402,0 266 UHB08-A311-01-00 252958173 ODU SLH 08GHZ TR A311 LO B1 7 731,0 7 867,0 311 UHH08-A311-01-00 252958181 ODU SLH 08GHZ TR A311 HI B1 8 042,0 8 178,0 311 UHB08-A311-02-00 252958194 ODU SLH 08GHZ TR A311 LO B2 7 835,0 7 971,0 311 UHH08-A311-02-00 252958206 ODU SLH 08GHZ TR A311 HI B2 8 146,0 8 282,0 311 UHB08-A311-03-00 253078990 ODU SLH 08GHZ TR A311 LO B3 7 717,0 7 867,0 311 UHH08-A311-03-00 253079009 ODU SLH 08GHZ TR A311 HI B3 8 028,0 8 178,0 311

11 GHz ODUs UHB11-A490-01-00 252958235 ODU SLH 11GHZ TR A490 LO B1 10 675,0 10 855,0 490 UHH11-A490-01-00 252958248 ODU SLH 11GHZ TR A490 HI B1 11 165,0 11 345,0 490 UHB11-A490-02-00 252958256 ODU SLH 11GHZ TR A490 LO B2 10 795,0 10 975,0 490 UHH11-A490-02-00 252958269 ODU SLH 11GHZ TR A490 HI B2 11 285,0 11 465,0 490 UHB11-A490-03-00 252958277 ODU SLH 11GHZ TR A490 LO B3 10 915,0 11 095,0 490 UHH11-A490-03-00 252958280 ODU SLH 11GHZ TR A490 HI B3 11 405,0 11 585,0 490

Page 131: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 131/134

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

UHB11-A490-04-00 252958298 ODU SLH 11GHZ TR A490 LO B4 11 035,0 11 215,0 490 UHH11-A490-04-00 252958300 ODU SLH 11GHZ TR A490 HI B4 11 525,0 11 705,0 490 UHB11-A490-05-00 253087580 ODU SLH 11GHZ TR A490 LO B5 10 700,0 10 890,0 490 & 500 UHH11-A490-05-00 253087593 ODU SLH 11GHZ TR A490 HI B5 11 200,0 11 390,0 490 & 500 UHB11-A490-06-00 253087600 ODU SLH 11GHZ TR A490 LO B6 10 855,0 11 045,0 490 & 500 UHH11-A490-06-00 253087613 ODU SLH 11GHZ TR A490 HI B6 11 355,0 11 545,0 490 & 500 UHB11-A490-07-00 253087642 ODU SLH 11GHZ TR A490 LO B7 11 010,0 11 200,0 490 & 500 UHH11-A490-07-00 253087655 ODU SLH 11GHZ TR A490 HI B7 11 510,0 11 700,0 490 & 500 UHB11-A530-01-00 252958318 ODU SLH 11GHZ TR A530 LO B1 10 675,0 10 855,0 530 UHH11-A530-01-00 252958321 ODU SLH 11GHZ TR A530 HI B1 11 205,0 11 385,0 530 UHB11-A530-02-00 252958339 ODU SLH 11GHZ TR A530 LO B2 10 795,0 10 975,0 530 UHH11-A530-02-00 252958342 ODU SLH 11GHZ TR A530 HI B2 11 325,0 11 505,0 530 UHB11-A530-03-00 252958350 ODU SLH 11GHZ TR A530 LO B3 10 915,0 11 135,0 530 UHH11-A530-03-00 252958363 ODU SLH 11GHZ TR A530 HI B3 11 445,0 11 665,0 530 UHB11-A530-04-00 252958371 ODU SLH 11GHZ TR A530 LO B4 11 035,0 11 215,0 530 UHH11-A530-04-00 252958384 ODU SLH 11GHZ TR A530 HI B4 11 565,0 11 745,0 530

13 GHz ODUs UHB13-A266-01-00 252958417 ODU SLH 13GHZ TR A266 LO B1 12 751,0 12 814,0 266 UHH13-A266-01-00 252958425 ODU SLH 13GHZ TR A266 HI B1 13 017,0 13 080,0 266 UHB13-A266-02-00 252958438 ODU SLH 13GHZ TR A266 LO B2 12 807,0 12 870,0 266 UHH13-A266-02-00 252958446 ODU SLH 13GHZ TR A266 HI B2 13 073,0 13 136,0 266 UHB13-A266-03-00 252958459 ODU SLH 13GHZ TR A266 LO B3 12 863,0 12 926,0 266 UHH13-A266-03-00 252958467 ODU SLH 13GHZ TR A266 HI B3 13 129,0 13 192,0 266 UHB13-A266-04-00 252958470 ODU SLH 13GHZ TR A266 LO B4 12 919,0 12 982,0 266 UHH13-A266-04-00 252958488 ODU SLH 13GHZ TR A266 HI B4 13 185,0 13 248,0 266

15 GHz ODUs UHB15-A315-01-00 252958511 ODU SLH 15GHZ TR A315 LO B1 14 627,0 14 732,0 315 UHH15-A315-01-00 252958529 ODU SLH 15GHZ TR A315 HI B1 14 942,0 15 047,0 315 UHB15-A315-02-00 252958532 ODU SLH 15GHZ TR A315 LO B2 14 725,0 14 844,0 315 UHH15-A315-02-00 252958540 ODU SLH 15GHZ TR A315 HI B2 15 040,0 15 159,0 315 UHB15-A315-03-00 252958553 ODU SLH 15GHZ TR A315 LO B3 14 823,0 14 928,0 315 UHH15-A315-03-00 252958561 ODU SLH 15GHZ TR A315 HI B3 15 138,0 15 243,0 315 UHB15-A420-01-00 252958574 ODU SLH 15GHZ TR A420 LO B1 14 501,0 14 613,0 420 UHH15-A420-01-00 252958582 ODU SLH 15GHZ TR A420 HI B1 14 921,0 15 033,0 420 UHB15-A420-02-00 252958595 ODU SLH 15GHZ TR A420 LO B2 14 606,0 14 725,0 420 UHH15-A420-02-00 252958607 ODU SLH 15GHZ TR A420 HI B2 15 026,0 15 145,0 420 UHB15-A420-03-00 252958615 ODU SLH 15GHZ TR A420 LO B3 14 718,0 14 837,0 420 UHH15-A420-03-00 252958628 ODU SLH 15GHZ TR A420 HI B3 15 138,0 15 257,0 420 UHB15-A420-04-00 252958636 ODU SLH 15GHZ TR A420 LO B4 14 816,0 14 928,0 420 UHH15-A420-04-00 252958649 ODU SLH 15GHZ TR A420 HI B4 15 236,0 15 348,0 420 UHB15-A475-01-00 253087663 ODU SLH 15GHZ TR A475 LO B1 14 500,0 14 668,0 475 UHH15-A475-01-00 253087676 ODU SLH 15GHZ TR A475 HI B1 14 975,0 15 143,0 475 UHB15-A475-02-00 253087684 ODU SLH 15GHZ TR A475 LO B2 14 660,0 14 828,0 475 UHH15-A475-02-00 253087697 ODU SLH 15GHZ TR A475 HI B2 15 135,0 15 303,0 475 UHB15-A475-03-00 253087759 ODU SLH 15GHZ TR A475 LO B3 14 783,0 14 883,0 475 UHH15-A475-03-00 253087762 ODU SLH 15GHZ TR A475 HI B3 15 258,0 15 358,0 475 UHB15-A490-01-00 252958657 ODU SLH 15GHZ TR A490 LO B1 14 403,0 14 522,0 490 UHH15-A490-01-00 252958660 ODU SLH 15GHZ TR A490 HI B1 14 893,0 15 012,0 490 UHB15-A490-02-00 252958678 ODU SLH 15GHZ TR A490 LO B2 14 515,0 14 634,0 490

Page 132: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Page 132/134 Sagem Communications document. Reproduction and disclosure prohibited

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

UHH15-A490-02-00 252958681 ODU SLH 15GHZ TR A490 HI B2 15 005,0 15 124,0 490 UHB15-A490-03-00 252958699 ODU SLH 15GHZ TR A490 LO B3 14 627,0 14 746,0 490 UHH15-A490-03-00 252958701 ODU SLH 15GHZ TR A490 HI B3 15 117,0 15 236,0 490 UHB15-A490-04-00 252958719 ODU SLH 15GHZ TR A490 LO B4 14 739,0 14 858,0 490 UHH15-A490-04-00 252958722 ODU SLH 15GHZ TR A490 HI B4 15 229,0 15 348,0 490 UHB15-A640-01-00 253087770 ODU SLH 15GHZ TR A640 LO B1 14 500,0 14 610,0 640 UHH15-A640-01-00 253087783 ODU SLH 15GHZ TR A640 HI B1 15 140,0 15 250,0 640 UHB15-A640-02-00 253087791 ODU SLH 15GHZ TR A640 LO B2 14 605,0 14 715,0 640 UHH15-A640-02-00 253087803 ODU SLH 15GHZ TR A640 HI B2 15 245,0 15 355,0 640 UHB15-A644-01-00 252958730 ODU SLH 15GHZ TR A644 LO B1 14 400,0 14 512,0 644 UHH15-A644-01-00 252958743 ODU SLH 15GHZ TR A644 HI B1 15 044,0 15 156,0 644 UHB15-A644-02-00 252958751 ODU SLH 15GHZ TR A644 LO B2 14 498,0 14 610,0 644 UHH15-A644-02-00 252958764 ODU SLH 15GHZ TR A644 HI B2 15 142,0 15 254,0 644 UHB15-A644-03-00 252958772 ODU SLH 15GHZ TR A644 LO B3 14 596,0 14 708,0 644 UHH15-A644-03-00 252958785 ODU SLH 15GHZ TR A644 HI B3 15 240,0 15 352,0 644 UHB15-A728-01-00 252958793 ODU SLH 15GHZ TR A728 LO B1 14 500,0 14 615,0 728 UHH15-A728-01-00 252958805 ODU SLH 15GHZ TR A728 HI B1 15 228,0 15 343,0 728

18 GHz ODUs UHB18-1010-01-00 252951038 ODU SLH 18GHZ TR 1010 LO B1 17 685,0 17 985,0 1010 UHH18-1010-01-00 252951046 ODU SLH 18GHZ TR 1010 HI B1 18 695,0 18 995,0 1010 UHB18-1010-02-00 252951111 ODU SLH 18GHZ TR 1010 LO B2 17 930,0 18 230,0 1010 UHH18-1010-02-00 252951132 ODU SLH 18GHZ TR 1010 HI B2 18 940,0 19 240,0 1010 UHB18-1010-03-00 252951145 ODU SLH 18GHZ TR 1010 LO B3 18 180,0 18 480,0 1010 UHH18-1010-03-00 252951153 ODU SLH 18GHZ TR 1010 HI B3 19 190,0 19 490,0 1010 UHB18-1010-04-00 252951166 ODU SLH 18GHZ TR 1010 LO B4 18 400,0 18 700,0 1010 UHH18-1010-04-00 252951174 ODU SLH 18GHZ TR 1010 HI B4 19 410,0 19 710,0 1010 UHB18-1560-01-00 252951187 ODU SLH 18GHZ TR 1560 LO B1 17 700,0 18 000,0 1560 UHH18-1560-01-00 252951195 ODU SLH 18GHZ TR 1560 HI B1 19 260,0 19 560,0 1560 UHB18-1560-02-00 252951314 ODU SLH 18GHZ TR 1560 LO B2 17 840,0 18 140,0 1560 UHH18-1560-02-00 252951088 ODU SLH 18GHZ TR 1560 HI B2 19 400,0 19 700,0 1560 UHB18-1560-03-00 252951091 ODU SLH 18GHZ TR 1560 LO B3 17 700,0 18 140,0 1560 UHH18-1560-03-00 252951405 ODU SLH 18GHZ TR 1560 HI B3 19 260,0 19 700,0 1560

23 GHz ODUs UHB23-1008-01-00 252958839 ODU SLH 23GHZ TR 1008 LO B1 21 994,0 22 330,0 1008 UHH23-1008-01-00 252958847 ODU SLH 23GHZ TR 1008 HI B1 23 002,0 23 338,0 1008 UHB23-1008-02-00 252958850 ODU SLH 23GHZ TR 1008 LO B2 22 274,0 22 610,0 1008 UHH23-1008-02-00 252958868 ODU SLH 23GHZ TR 1008 HI B2 23 282,0 23 618,0 1008 UHB23-1200-01-00 252958871 ODU SLH 23GHZ TR 1200 LO B1 21 200,0 21 530,0 1200 UHH23-1200-01-00 252958889 ODU SLH 23GHZ TR 1200 HI B1 22 400,0 22 730,0 1200 UHB23-1200-02-00 252958892 ODU SLH 23GHZ TR 1200 LO B2 21 490,0 21 820,0 1200 UHH23-1200-02-00 252958909 ODU SLH 23GHZ TR 1200 HI B2 22 690,0 23 020,0 1200 UHB23-1200-03-00 252958912 ODU SLH 23GHZ TR 1200 LO B3 21 780,0 22 110,0 1200 UHH23-1200-03-00 252958920 ODU SLH 23GHZ TR 1200 HI B3 22 980,0 23 310,0 1200 UHB23-1200-04-00 252958933 ODU SLH 23GHZ TR 1200 LO B4 22 070,0 22 400,0 1200 UHH23-1200-04-00 252958941 ODU SLH 23GHZ TR 1200 HI B4 23 270,0 23 600,0 1200 UHB23-1200-05-00 253087845 ODU SLH 23GHZ TR 1200 LO B5 21 200,0 21 600,0 1200 UHH23-1200-05-00 253087853 ODU SLH 23GHZ TR 1200 HI B5 22 400,0 22 800,0 1200

Page 133: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

SAGEM-LINK F-H Installation and Operation Manual – 253 129 101-01 Sagem Communications document. Reproduction and disclosure prohibited Page 133/134

Transmit frequencies (1) Duplex spacing Type Reference Description Min. Freq.

(MHz) Max. Freq.

(MHz) (MHz)

UHB23-1200-06-00 253087866 ODU SLH 23GHZ TR 1200 LO B6 21 600,0 22 000,0 1200 UHH23-1200-06-00 253087874 ODU SLH 23GHZ TR 1200 HI B6 22 800,0 23 200,0 1200 UHB23-1200-07-00 253087887 ODU SLH 23GHZ TR 1200 LO B7 22 000,0 22 400,0 1200 UHH23-1200-07-00 253087952 ODU SLH 23GHZ TR 1200 HI B7 23 200,0 23 600,0 1200 UHB23-1232-01-00 252958954 ODU SLH 23GHZ TR 1232 LO B1 21 200,0 21 500,0 1232 UHH23-1232-01-00 252958962 ODU SLH 23GHZ TR 1232 HI B1 22 432,0 22 732,0 1232 UHB23-1232-02-00 252958975 ODU SLH 23GHZ TR 1232 LO B2 21 472,0 21 786,0 1232 UHH23-1232-02-00 252958983 ODU SLH 23GHZ TR 1232 HI B2 22 704,0 23 018,0 1232 UHB23-1232-03-00 252958996 ODU SLH 23GHZ TR 1232 LO B3 21 779,0 22 093,0 1232 UHH23-1232-03-00 252959005 ODU SLH 23GHZ TR 1232 HI B3 23 011,0 23 325,0 1232 UHB23-1232-04-00 252959018 ODU SLH 23GHZ TR 1232 LO B4 22 086,0 22 386,0 1232 UHH23-1232-04-00 252959026 ODU SLH 23GHZ TR 1232 HI B4 23 318,0 23 618,0 1232

26 GHz ODUs UHB26-A800-01-00 252959050 ODU SLH 26GHZ TR A800 LO B1 24 250,0 24 450,0 800 UHH26-A800-01-00 252959068 ODU SLH 26GHZ TR A800 HI B1 25 050,0 25 250,0 800 UHB26-1008-01-00 252959071 ODU SLH 26GHZ TR 1008 LO B1 24 549,0 24 885,0 1008 UHH26-1008-01-00 252959089 ODU SLH 26GHZ TR 1008 HI B1 25 557,0 25 893,0 1008 UHB26-1008-02-00 252959092 ODU SLH 26GHZ TR 1008 LO B2 24 829,0 25 165,0 1008 UHH26-1008-02-00 252959104 ODU SLH 26GHZ TR 1008 HI B2 25 837,0 26 173,0 1008 UHB26-1008-03-00 252959112 ODU SLH 26GHZ TR 1008 LO B3 25 109,0 25 445,0 1008 UHH26-1008-03-00 252959125 ODU SLH 26GHZ TR 1008 HI B3 26 117,0 26 453,0 1008

32 GHz ODUs UHB32-A812-01-00 252959154 ODU SLH 32GHZ TR A812 LO B1 31 815,0 32 207,0 812 UHH32-A812-01-00 252959167 ODU SLH 32GHZ TR A812 HI B1 32 627,0 33 019,0 812 UHB32-A812-02-00 252959175 ODU SLH 32GHZ TR A812 LO B2 32 179,0 32 571,0 812 UHH32-A812-02-00 252959188 ODU SLH 32GHZ TR A812 HI B2 32 991,0 33 383,0 812

38 GHz ODUs UHB38-A700-01-00 253087960 ODU SLH 38GHZ TR A700 LO B1 38 595,0 38 805,0 700 UHH38-A700-01-00 253087981 ODU SLH 38GHZ TR A700 HI B1 39 295,0 39 505,0 700 UHB38-A700-02-00 253088003 ODU SLH 38GHZ TR A700 LO B2 38 795,0 39 005,0 700 UHH38-A700-02-00 253088024 ODU SLH 38GHZ TR A700 HI B2 39 495,0 39 705,0 700 UHB38-A700-03-00 253088037 ODU SLH 38GHZ TR A700 LO B3 38 995,0 39 205,0 700 UHH38-A700-03-00 253088045 ODU SLH 38GHZ TR A700 HI B3 39 695,0 39 905,0 700 UHB38-A700-04-00 253088058 ODU SLH 38GHZ TR A700 LO B4 39 195,0 39 405,0 700 UHH38-A700-04-00 253088066 ODU SLH 38GHZ TR A700 HI B4 39 895,0 40 105,0 700 UHB38-1260-01-00 252959216 ODU SLH 38GHZ TR 1260 LO B1 37 044,0 37 632,0 1260 UHH38-1260-01-00 252959229 ODU SLH 38GHZ TR 1260 HI B1 38 304,0 38 892,0 1260 UHB38-1260-02-00 252959237 ODU SLH 38GHZ TR 1260 LO B2 37 604,0 38 192,0 1260 UHH38-1260-02-00 252959240 ODU SLH 38GHZ TR 1260 HI B2 38 864,0 39 452,0 1260

Note 1: the minimum and maximum frequencies in these tables correspond to the ODU diplexer bandwidth transmission side, not channel frequencies. The channel frequencies available depend on the selected channel occupied bandwidth. The frequency of the first channel is equal to the minimum diplexer frequency + half the band corresponding to the transmitted spectrum. The frequency of the last channel is equal to the maximum diplexer frequency - half the band corresponding to the transmitted spectrum. The band corresponding to the transmitted spectrum is 40 MHz for a 56 MHz Tx/Tx spacing, 20 MHz for a 28 MHz Tx/Tx spacing (see also § 6.2.5 -).

Page 134: Sagem - Link F-H Microwave Installation and Operation Manual(2008)

Registered office: Le Ponant de Paris - 27, rue Leblanc - 75 015 PARIS - France Tel.: +33 (0)1 58 11 77 00 - Fax: +33 (0)1 58 11 77 77 http://www.sagem-communications.com SAS with the capital of 158 291 895 € - 440 294 510 RCS Paris