Safety and protection installations

114
Safety and protection installations Insulation & cable bandages

Transcript of Safety and protection installations

Safety and protectioninstallations

Insulation & cable bandages

Our products for your projectTowards the future with OBO

Reliable, safe and of the highest quality: Product features such asinstallation speed, load capacity, functionality and availability areat the forefront of each of our innovations. Discover the wholerange of OBO products – in a new structure, allowing us to deal ina more targeted manner with the needs of you, our customers.

It is our aim to be the first port of call for the best and most innova-tive connections for electrical and data technology infrastructure.Thus, when looking towards the future, we have asked ourselveswhat we can do to be the best possible partner you could everimagine, also in the long term. Against this backdrop, we haveoptimised our structure once again, sharpened our profile anddefined our services more clearly. The result: Three new areas ofapplication, which replace our previous seven product units, inorder to provide you with a contemporary and user-orientatedvisual identity and structure, for both products and communica-tion. This helps you to find exactly the products you are looking forin an even faster and simpler manner.

In this catalogue, we will present to you the variety of the entireproduct range of the safety and protection installations applicationarea. Here, one thing – above all else – is in the spotlight: Safety.Besides our expert knowledge in this field, we place particularemphasis on innovations in product development and comprehen-sive quality testing, in order to offer you maximum protection at alltimes.

Our products for surge and lightning protection provide reliableprotection against the impacts of thunderstorms and remote swit-ching operations. These can cause not only significant damage toproperty, but also endanger human lives. The unique, wide pro-duct range in the field of fire protection makes OBO one of the fewproviders who cover all three protection aims and help you to pro-tect people and property as best as possible in case of fire.

OBO ‒ simply better.

2

  OBO Product Worlds

 

Safety and protection installationsSurge protectionExplosion protectionLightning protectionEarthingEquipotential bondingInsulationCable bandages – prevention of the spread of fireEscape route installations – false ceiling mountingFire protection ductsSystems for the maintenance of electrical functionality – cable-specific routing variantsSystems for the maintenance of electrical functionality – standard support structures and routing systemsSystems for the maintenance of electrical functionality – FireBox T series junction boxesAnchorings

You can find additional products in our newIndustrial installations and Building installati-ons catalogues

 Industrial installationsCable support systems and connection andfastening systems for industry and construction project infrastructureCable traysMesh cable traysCable laddersIndustrial ductsSupport structuresElectrical installation pipesWiring ductsPower supply unitsDistributorsJunction boxesConcealed and cavity wall installationsTerminalsCable glandsInstallation and fastening clipsAnchors and fastening systems

 Building installationsCable routing and underfloor systems foradministrative and functional buildings including architectural solutionsElectrical installation ducts and trunkingDevice installation ducts and trunkingSkirting trunkingService polesUnderfloor applications, in screedUnderfloor applications, in concreteUnderfloor applications, on-floorService outlets for underfloor applicationsFloor sockets and floor boxesInstallation housing and supportTabletop socketsSockets, switches, data and multimedia technology

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

3

Contents

4

6955640

Directories Page 104

Cable bandages – prevention of the spread offire

Page 94

Insulation – maintenance of the fire sections Page 10

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

 

Welcome world.Welcome to OBO.New solutions to improve functionality and the ease of instal-lation – OBO employees all around the world use their abili-ties and creativity to make this happen. Because we knowthat each individual market has its special characteristics andthat the requirements for our products change within eachmarket, we have paid particular attention to the compatibilityof products in their place of use. We always offer our custo-mers intelligent, well-thought-out solutions. Our brands alwayskeep this promise. The OBO global team wishes to make thework of electrical planners and operatives around the worldas easy as possible.

6

 

 

 

Production location

 

Subsidiary

 

Representative office

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

7

OBO Support& contact

 

 

You have aproblem?

We have thesolution!

OBO Bettermann is more than the sum of itsproducts. In any situation, we are the relia-ble partner right buy your side. You have aproblem? We have the solution!

It doesn’t matter in which area of industryour support is needed - from industrial andplant engineering to private, public andadministrative buildings, as well as in theareas of mobility and renewable energies -we have all that you need.

OBO can not only provide the entire electro-technical infrastructure with the best possi-ble products. We can also support you withsound expert knowledge and more than 100years of experience, right from the planningphase through to the realisation of your pro-jects. OBO - solutions you can rely on.

8

 

 

You can contact our Customer Service depart-ment on:

+49 2373 89 1700Monday–Thursday07.30–17.00

Friday07.30–15.00

[email protected]

 

Service Training Handling Certification

Service – OBO can helpEverywhere and in every projectphase:• Competent hotline• Product and system information,

digitally or printed• Selection and planning aids on the

web, as an app, as a CAD applica-tion or in printed form

• 2D and 3D product data for plan-ning

• Field service, branch offices andsubsidiaries in 60 countries

• Engineering services for major pro-jects

Training courses from OBO• Seminars and workshops• Local consultation and training

courses• Planner days

Handling – OBO delivers reliablyWith optimised delivery processes:• Reliable logistics• Practical transport systems and

packaging• Loading gear handling and dispo-

sal concepts

Certification and guaranteeOBO offers safety. Our products fulfilthe most important country-specificregulations:• Conformity (e.g. IEC, VDE, CE,

KEMA, KEUR, UL)• Certification (e.g. DIN EN, DGNB)• 5-year guarantee for surge protec-

tion products• Guarantee management

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

9

Insulation - maintenance of thefire sections

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

10

Insulation - maintenance of thefire sections

PYROPLUG® Mini small insulation 88

PYROCOMB® Intube pipe shell 80

PYROCOMB® pipe sleeve 68

PYROPLUG® foam series 44

PYROSIT® NG fire protection foam 36

PYROBAG® bag insulation 30

PYROPLATE® Fibre soft insulation 22

PYROMIX® mortar insulation 12

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

11

PYROMIX® - Mortar insulation System description

 

 

The PYROMIX® system from OBO is used to createcable and combination insulation made of a mine-ral fibre-free special mortar. Depending on theamount of water added, the finished compoundcan be applied to openings by hand, with pumpsor with presses. The high level of substrate adhe-

sion makes lining unnecessary for small insulationareas. The porous consistency of the mortarmeans that retroinstallation is easy. If there is a fire,the fire protection mortar reliably prevents thespread of fire and smoke.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

12

PYROMIX® - Mortar insulation Installation principle

Stir the mortar with water until thedesired consistency is reached. 

Apply mortar to the opening, uselining as necessary. 

Use approved section insulationfor metal pipes. 

Section insulation should also beapplied to steel electrical installa-tion pipes. 

Mount pipe sleeves for combusti-ble pipes on both sides of thewall. 

Apply labelling to combinationinsulation for various structures. 

Classification to DIN

    

     

Classification to EN

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

13

PYROMIX® - Mortar insulation Registration data

Combination insulation in walls/ceilingsFire resistance class EI 180, EI 240

Proof of application European Technical Assessment of DIBt, Berlin

Approval number ETA-17/0472

Testing standard EN 1366-3 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

15 cm(EI 60 / EI 90 / EI 120) ‒

15 cm(S30 / S60 / S90)

Min. insulation thickness 

15 cm(EI 60 / EI 90 / EI 120)24 cm (EI 120)

‒15 cm(EI 60 / EI 90 / EI 120)24 cm (EI 120)

Opening size 

 

≤ 120 cm (for EI 120)≤ 200 cm

 

 

120 cm (for EI 120)≤ 60 cm x ≤ 60 cm

 

120 cm (for EI 120)≤ 60 cm x ≤ 60 cm

 

‒ 

≤ 100 cmUnlimited

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

14

PYROMIX® - Mortar insulation Installations

Cable

Ø 80 mm 

 

Pipe bundle of electrical installation pipes

Only with PYROCOMB Intube 

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

Ø 16 mm,cable Ø 16 mm  

 

Individual lines for control purposes

 

 

Cable support systems

Steel profiles 

 

Electrical installation pipe made of plastic, rigid

Ø 16 mm,cable Ø 21 mm  

 

Metal pipes with path insulation

Steel, stainless steel andcast steel Ø 323.9 mm,copper Ø 108.0 mm

 

 

Electrical installation pipe made of plastic, flexible

Only with PYROCOMB Intube 

 

Plastic pipes

Ø 160 mm 

 

Special installations

Double solar pipes

Stainless steel with insulation+ accompanying cable Ø40 mm(Ceiling 30 min.)

 

 

Speed pipe

24 pipes Ø 7 mm x 1.5 m,7 pipes Ø 10 mm x 2.0 m,5 pipes Ø 12 mm x 2.0 mm,Ø 50 mm total

 

 

Klimasplit

Tubolit Duo SplitØ 6.0‒18.0 mm  

 

Hydraulic hoses

HANSA-FLEX HD 200-2 SNØ 55.9 mm (150 mm compo-nent)

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

15

Mortar insulation PYROMIX®

PYROMIX® dry mortar in paper sack  

 

 

 

20TypeMSX-S1

Contentskg

Weightkg/100 pc.2,000.000

Item no.7206104

PackPiece1

Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pres-sing and for manual installation. Adding approx. 6 litres of water to 20 kg of dry mortar produces about 20litres of workable compound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.

 

PYROMIX® dry mortar in bucket  

 

 

 

10TypeMSX-E1

Contentskg

Weightkg/100 pc.1,000.000

Item no.7206058

PackPiece1

Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pres-sing and for manual installation. Adding approx. 3 litres of water to 10 kg of dry mortar produces about 10litres of workable compound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.

 

Insulation layer creator in a cartridge  

 

 

Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for the closing of core drill holes when feeding through single cables and for closing the annular gap whenexiting cables from the PYROLINE® Con PLC fire protection duct. Material class DIN 4102 - B2, normally flam-mable. In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.

 

300TypeDSX-K

Contentsml

Weightkg/100 pc.50.000

Item no.7202300

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

16

Mortar insulation PYROMIX®

  Insulation layer creator in a bucket

Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for closing core drill holes for individual cable glands.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.

 

5TypeDSX-E

Contentskg

Weightkg/100 pc.500.000

Item no.7202302

PackPiece1

 

 

 

  Pipe sleeve with 2 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M6 threaded rods.

 

32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54

TypeTCX-032TCX-040TCX-050

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.6.5007.0008.000

Item no.720220072022017202203

PackPiece111

 

 

 

  Pipe sleeve with 4 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.

 

63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129

TypeTCX-063TCX-075TCX-090TCX-110TCX-125

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.15.50019.00037.00046.00070.000

Item no.72022047202205720220672022077202208

PackPiece11111

 

 

 

  Pipe sleeve with 6 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

140 - 142 40 200 144160 - 162 40 220 164

TypeTCX-140TCX-160

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.106.000107.000

Item no.72022097202210

PackPiece11

 

 

 

  Threaded rod

Threaded rod to DIN 976. 

M6 6 1000M8 8 1000

TypeTR M6 1M GTR M8 1M G

Thread

Dim.dmm

Dim.Lmm

Weightkg/100 pc.18.30030.000

Item no.31410473141128

PackPiece1010

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

17

Mortar insulation PYROMIX®

Hexagonal nut DIN 934  

 

 

Hexagonal nut to DIN 934 with metric thread. 

M6 10 5.2 6M8 13 6.8 8

TypeHN M6 GHN M8 G

ThreadSWmm

Dim. hmm

Dim.dmm

Weightkg/100 pc.0.2210.500

Item no.34000693400085

PackPiece100100

 

Washer ISO 7093  

 

 

Washer of large outer diameter for universal use. 

M6 6.5 28 2.5M8 8.5 28 2.5

TypeWS M6 D28 GWS M8 D28 G

Thread

Dim.dmm

Dim. Dmm

Dim. hmm

Weightkg/100 pc.1.1041.100

Item no.34022073402215

PackPiece100100

 

MMS-plus P round head tie, with panhead  

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With roundhead for universal fastenings. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

6 x 50 5 11.2 Torx 50TypeMMS+ P 6x50

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Dim.Lmm

Weightkg/100 pc.1.000

Item no.3498108

PackPiece100

 

MMS-plus MS mounting rail tie, with flat pan-head

 

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx

TypeMMS+ MS 7.5x50MMS+ MS 7.5x60

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Weightkg/100 pc.1.5001.800

Item no.34982613498262

PackPiece10050

 

Section insulation for metal pipes  

 

 

Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.

Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks

Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C 

6100 500 30TypeMIW-MA

Lengthmm

Widthmm

Thicknessmm

Weightkg/100 pc.1,010.000

Item no.7202308

PackPiece2

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

18

Mortar insulation PYROMIX® 

Aluminium adhesive tape for path insulation

Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.

 

100 100TypeMIW-AT

Lengthm

Widthmm

Weightkg/100 pc.136.900

Item no.7202305

PackPiece1

 

 

 

  Winding wire for path insulation

The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.

 

50TypeMIW-TD

Lengthm

Weightkg/100 pc.10.000

Item no.7202309

PackPiece1

 

 

 

 

Bandage for insulation

Coated fire protection coil with material that foams up in the event of fire for wrapping installations in thePYROMIX® mortar insulation and PYROPLATE® Fibre plate insulation.

The coil can be used as an addition, according to the appropriate proof of suitability. 

10 125TypeFSB-WB 1.5

Lengthm

Widthmm

Weightkg/100 pc.220.000

Item no.7203163

PackPiece1

 

 

 

  Mineral wool

Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.

 

25 LiterTypeMIW-S

Dimension Weightkg/100 pc.250.000

Item no.7202306

PackPiece1

 

 

 

  Calcium silicate plate

Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.

 

500 150 20500 250 301000 250 30

TypeKSI-P1KSI-P2KSI-P3

Dim.Lmm

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.42.000111.000222.000

Item no.720228372029047202912

PackPiece111

 

 

L

BD

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

19

Mortar insulation PYROMIX®

PYROCOMB® Intube pipe shell, Ø 120 mm  

 

 

Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.

 

150 116.4 107 125300 116.4 107 125

TypeCTS 12150CTS 12300

Dim.Lmm

Dim. Bmm

Dim. Dmm

ForopeningØ mm

Weightkg/100 pc.35.20070.000

Item no.72043007204304

PackPiece11

 

Identification plate  

 

100

70

25

Ø 7

85

 

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

Support construction for insulations, withbracket

 

 

 

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.

 

70 217 50TypeSKA 05 VZ

Dim.Hmm

Dim. Bmm

Dim.Amm

Weightkg/100 pc.190.740

Item no.7202436

PackPiece1

 

Support construction for insulations, with pen-dulum suspension

 

 

 

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.

 

1000TypeSKP 05 VZ

Dim.Lmm

Weightkg/100 pc.235.240

Item no.7202446

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

rese

ctio

ns

20

21

Soft insulation, PYROPLATE® Fibre System description

 

 

The PYROPLATE® Fibre system from OBO is usedto create cable and combination insulation. Thecore of the system is the mineral fibre plate coatedwith a moisture-resistant ablation coating. Whenthere is a fire, the fire protection coating creates aninsulating carbon foam and, in combination withthe mineral fibre plate, prevents the spread of fireand smoke. According to the European Technical

Assessment, in addition to the cables, pipes madeof steel, copper or various plastics may also be runthrough the same insulation. For pipelines, additio-nal fire protection measures, such as section insu-lation and pipe sleeves, are required. The mortar orsoft insulation made of PYROPLATE® Fibre is thuscombination insulation which is appropriate fordiverse structures.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

22

Soft insulation, PYROPLATE® Fibre Installation principle

The installation is possible in light-duty partition walls or in solidwalls. 

Moisten the component layer andapply the coating to the cutedges for adhesion. 

The plates can be inserted care-fully with a hammer and board. 

Use approved section insulationfor metal pipes. 

Apply the final coating to the sur-face and the installations. 

Secure soft insulation in ceilingsagainst footfall. 

Cut the plates for mounting. 

Finished installation in a light-dutypartition wall. 

Classification to DIN

    

     

Classification to EN

               

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

23

Soft insulation, PYROPLATE® Fibre Registration data

Combination insulation in walls and ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120, EI, 180, EI 240

Proof of application European Technical Assessment of DIBt, Berlin

Approval number ETA-17/0364

Testing standard DIN EN 1366 Part 3 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm (EI 15 / EI 30 / EI 60/ EI 90) 10 cm (EI 15 / EI 30/ EI 60 / EI 90/ EI 120)20 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 /EI240)

10 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)

12.5 cm (EI 15 / EI 30 / EI60 / EI 90)15 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)20 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 /EI240)

Min. insulation thickness 

6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)24 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 / EI240)

6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)

6 cm (EI 15 / EI 30 / EI 60 /EI 90)12 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120)24 cm (EI 15 / EI 30 / EI 60/ EI 90 / EI 120 / EI 180 / EI240)

Opening sizefor 6 cm insulation thick-ness

  

≤ 117.5 cm≤ 120 cm

 

≤ 117.5 cm≤ 120 cm

 

≤ 120 cm x ≤ 240 cm≤ 80 cm x ≤ unlimited

Opening sizefor 12 cm insulation thick-ness  

 

≤ 140 cm≤ 200 cm

 

≤ 140 cm≤ 200 cm

 

≤ 140 cm≤ 200 cm

Opening sizefor 24 cm insulation thick-ness

  

≤ 60 cm≤ 60 cm

 

‒ 

≤ 60 cm≤ Unlimited

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

24

Soft insulation, PYROPLATE® Fibre Installations

Cable

Cable Ø 80 mm 

 

Pipe bundle of electrical installation pipes

Ø 100 mm, IR Ø 32 mm,cable Ø 21 mm  

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

Steel profiles 

 

Electrical installation pipe made of plastic, rigid

Ø 16 mm 

 

Metal pipes with path insulation

Steel, stainless steel andcast steel Ø 332.9 mm,copper Ø 108.0 mm

 

 

Electrical installation pipe made of plastic, flexible

Ø 32 mm,cable Ø 21 mm  

 

Plastic pipes

Ø 160 mm 

 

Special installations

Speed pipe

24 pipes Ø 7 mm x 1.5 m,7 pipes Ø 10 mm x 2.0 m,5 pipes Ø 12 mm x 2.0 mm,Ø 50 mm total

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Double solar pipes

"NanoSUN" DN 16 to DN 40 

 

Klimasplit

"Tubolit DuoSplit", "TubolitSplit" or comparable6.0 mm–22.0 mm

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

25

Soft insulation, PYROPLATE® Fibre

Mineral fibre plate, pre-coated  

 

H

 

Mineral fibre plate, pre-coated with the ablation coating ASX, as the basis for the soft insulation. 50 mm plate forinsulation according to German approval, 60 mm plate for insulation according to European approval.

 

1000 600 50TypePSX-P

Lengthmm

Widthmm

Heightmm

Weightkg/100 pc.625.000

Item no.7202295

PackPiece4

 

Ablation coating PYROCOAT® in a cartridge  

 

 

 

310TypeASX-K

Contentsml

Weightkg/100 pc.50.000

Item no.7202310

PackPiece1

Combined, endothermic and weatherproof coating for internal and external areas. Universal protectioncoating for cable and cable support structures. Use as direct filler, and as paint when stirred.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.

 

Ablation coating PYROCOAT® in a bucket  

 

 

 

5TypeASX-E

Contentskg

Weightkg/100 pc.500.000

Item no.7202312

PackPiece1

Combined, endothermic and weatherproof coating for internal and external areas. Universal protectioncoating for cable and cable support structures. Use as direct filler, and as paint when stirred. Sufficient foran area of 4 m².Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

26

Soft insulation, PYROPLATE® Fibre

  Pipe sleeve with 2 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M6 threaded rods.

 

32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54

TypeTCX-032TCX-040TCX-050

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.6.5007.0008.000

Item no.720220072022017202203

PackPiece111

 

 

 

  Pipe sleeve with 4 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.

 

63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129

TypeTCX-063TCX-075TCX-090TCX-110TCX-125

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.15.50019.00037.00046.00070.000

Item no.72022047202205720220672022077202208

PackPiece11111

 

 

 

  Pipe sleeve with 6 fastening straps

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a very great pressure onto theburning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

140 - 142 40 200 144160 - 162 40 220 164

TypeTCX-140TCX-160

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.106.000107.000

Item no.72022097202210

PackPiece11

 

 

 

  Threaded rod

Threaded rod to DIN 976. 

M6 6 1000M8 8 1000

TypeTR M6 1M GTR M8 1M G

Thread

Dim.dmm

Dim.Lmm

Weightkg/100 pc.18.30030.000

Item no.31410473141128

PackPiece1010

 

 

 

  Hexagonal nut DIN 934

Hexagonal nut to DIN 934 with metric thread. 

M6 10 5.2 6M8 13 6.8 8

TypeHN M6 GHN M8 G

ThreadSWmm

Dim. hmm

Dim.dmm

Weightkg/100 pc.0.2210.500

Item no.34000693400085

PackPiece100100

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

27

Soft insulation, PYROPLATE® Fibre

Washer ISO 7093  

 

 

Washer of large outer diameter for universal use. 

M6 6.5 28 2.5M8 8.5 28 2.5

TypeWS M6 D28 GWS M8 D28 G

Thread

Dim.dmm

Dim. Dmm

Dim. hmm

Weightkg/100 pc.1.1041.100

Item no.34022073402215

PackPiece100100

 

Bandage for insulation 

 

 

Coated fire protection coil with material that foams up in the event of fire for wrapping installations in thePYROMIX® mortar insulation and PYROPLATE® Fibre plate insulation.

The coil can be used as an addition, according to the appropriate proof of suitability. 

10 125TypeFSB-WB 1.5

Lengthm

Widthmm

Weightkg/100 pc.220.000

Item no.7203163

PackPiece1

 

Section insulation for metal pipes  

 

 

Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.

Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks

Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C 

6100 500 30TypeMIW-MA

Lengthmm

Widthmm

Thicknessmm

Weightkg/100 pc.1,010.000

Item no.7202308

PackPiece2

 

Aluminium adhesive tape for path insulation 

 

 

Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.

 

100 100TypeMIW-AT

Lengthm

Widthmm

Weightkg/100 pc.136.900

Item no.7202305

PackPiece1

 

Winding wire for path insulation  

 

 

The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.

 

50TypeMIW-TD

Lengthm

Weightkg/100 pc.10.000

Item no.7202309

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

28

Soft insulation, PYROPLATE® Fibre

  Mineral wool

Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.

 

25 LiterTypeMIW-S

Dimension Weightkg/100 pc.250.000

Item no.7202306

PackPiece1

 

 

 

  Calcium silicate plate

Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.

 

500 150 20500 250 301000 250 30

TypeKSI-P1KSI-P2KSI-P3

Dim.Lmm

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.42.000111.000222.000

Item no.720228372029047202912

PackPiece111

 

 

L

BD

 

  PYROCOMB® Intube pipe shell, Ø 120 mm

Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.

 

150 116.4 107 125300 116.4 107 125

TypeCTS 12150CTS 12300

Dim.Lmm

Dim. Bmm

Dim. Dmm

ForopeningØ mm

Weightkg/100 pc.35.20070.000

Item no.72043007204304

PackPiece11

 

 

 

  Identification plate

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

 

100

70

25

Ø 7

85

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

29

PYROBAG® Bag insulation System description

 

 

The PYROBAG® system from OBO is used tocreate cable insulation from fire protection cus-hions. The fire protection cushions, which can beshaped in any way, are stacked simply and quicklyon top of each other, allowing absolutely tidy anddust-free mounting. The cushions can be used forpermanent or temporary insulation in walls and cei-lings, e.g. during renovations. The fire protectioncushions are an ideal solution for frequent retroin-

stallations. Additional cables can be installedquickly, neatly and economically at a later datebecause the cushions can be used several timesover. The cushions consist of a close-knit, denseand mechanically solid glass fabric with a specialfilling. The shell and the filling are free of mineralfibres and are also weatherproof and waterproof.Neither painting nor the use of filler are required.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

30

PYROBAG® Bag insulation Installation principle

Closing of the opening with cushi-ons – without filler or coating. 

Panels as mounting aid for thelast cushion layer. 

Lock against falling out duringceiling mounting. 

Lock against slippage above thefloor. 

Cushions arranged in the duct. 

Retaining profile to prevent slip-page in vertical arrangements. 

Discreet attachment of the identifi-cation plate. 

Classification to DIN

    

     

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

31

PYROBAG® Bag insulation Registration data

Insulation in walls/ceilingsFire resistance class S30, S60, S90

Proof of application General construction approval of DIBt, Berlin

Approval number Z- 19. 15-1115

Testing standard DIN 4102 Part 9 

Insulation in cable routing ductsFire resistance class S90

Proof of application General construction approval of DIBt, Berlin

Approval number Z-19.15-1119

Testing standard DIN 4102 Part 9 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm(S30/S60/S90)

10 cm(S30/S60/S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

35 cm(S30 / S60 / S90)

35 cm(S30 / S60 / S90)

35 cm(S30 / S60 / S90)

Opening size 

 

≤ 100 cm,≤ 150 cm

 

≤ 100 cm,≤ 100 cm

 

≤ 60 cm,unlimited

Insulation in cable ducts

Component Rigid walls Flexible walls Rigid floors

     

Min. insulation thickness10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Duct size35 cm(S30 / S60 / S90)

35 cm(S30 / S60 / S90)

35 cm(S30 / S60 / S90)

Plastic ducts 21 cm x 10 cm 21 cm x 10 cm 21 cm x 10 cm

Metal ducts 21 cm x 8 cm 21 cm x 8 cm 21 cm x 8 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

32

PYROBAG® Bag insulation Installations

Cable

All Ø 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

Ø 150 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

Profiles made of steel, alumi-nium or plastic  

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

 

 

Plastic pipes

 

 

Special installations

Plastic ducts

210 × 100 mm, wall thickness≤ 3.5 mm  

 

Insulation in the lining pipe

Ø 200 mm,wall thickness 3.5 mm, PVC  

 

Metal ducts

210 × 80 mm, wall thickness≤ 2.0 mm  

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

33

PYROBAG® bag insulation

PYROBAG® fire protection cushion  

 

 

Cable fire protection cushions made of dense, closely knit and mechanically solid glass mesh with a special filling.Free from mineral fibres, weatherproof and water-resistant.Can be stored for an unlimited period of time in dry, frost-free rooms.

 

120 10170 23170 40

TypeKBK-1KBK-2KBK-3

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.18.00033.00063.000

Item no.720270972027257202741

PackPiece555

 

Steel wire grid  

 

 

Steel wire grid as support and protection grid, wire diameter 4 mm. 

600 5001000 600

TypeSDG-1SDG-2

Dim.Lmm

Dim. Bmm

Weightkg/100 pc.135.000270.000

Item no.72029637202971

PackPiece11

 

MMS-plus MS mounting rail tie, with flat pan-head

 

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx

TypeMMS+ MS 7.5x50MMS+ MS 7.5x60

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Weightkg/100 pc.1.5001.800

Item no.34982613498262

PackPiece10050

 

Calcium silicate plate  

 

L

BD

 

Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.

 

500 150 20500 250 301000 250 30

TypeKSI-P1KSI-P2KSI-P3

Dim.Lmm

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.42.000111.000222.000

Item no.720228372029047202912

PackPiece111

 

Identification plate  

 

100

70

25

Ø 7

85

 

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

34

35

Fire protection foam PYROSIT® NG System description

 

 

The PYROPLATE® NG system from OBO is used tocreate cable and combination insulation made offire protection foam. The special recipe of the 2-component foam allows simple, "pinpointed" pro-cessing. The good substrate adhesion prevents thefoam from running out of the opening. Work caneasily be interrupted to carry out checks. The sys-tem can be installed without dust and fibres. Sur-face coating is not necessary. According to the

construction approval, in addition to the cables,pipes made of steel, copper or various plasticsmay also be run through the same insulation. ThePYROSIT® NG insulation is suitable as combinationinsulation for different units. Due to the soft consis-tency, the insulation made of PYROSIT® NG can bereassigned simply. The insulation system can becombined with the PYROPLUG® Block foam block.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

36

Fire protection foam PYROSIT® NG Installation principle

Clean the layer and attach thelining aids, e.g. adhesive tape. 

Apply the foam from the rear tothe front, and remove residues asnecessary. 

Use approved section insulationfor metal pipes. 

Electrical installation pipes up toM40, filled with cables or empty. 

Combustible pipes up to Ø50  mm can be run throughwithout additional measures. 

Combination insulation for variousstructures with labelling. 

Application of the fire protectionfoam directly under the wall. 

Labelled underfloor insulation withreserve empty pipe. 

Empty pipes with tension wirescan be foamed in for assignmentat a later date. 

Classification to EN

           

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

37

Fire protection foam PYROSIT® NG Registration data

Combination insulation in walls/ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120

Proof of application European Technical Assessment of OIB, Vienna

Approval number ETA-11/0527

Testing standard EN 1366-3 

Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-002/2012

Air permeation/pressure resistance ift Rosenheim, 11-003694-PR03

Noise insulation HfT Stuttgart, 122-007-04P-186a 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm(EI30 / EI60 / EI90 / EI120)

10 cm(EI30 / EI60 / EI90 / EI120)

15 cm(EI30 / EI60 / EI90 / EI120)

Min. insulation thickness 

14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)

14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)

14.4 cm(IET90 / IET150)20 cm (IET 90 / IET 150)

Opening size for 14.4 cminsulation thickness

  

≤ 45 cm≤ 50 cm

 

≤ 45 cm≤ 50 cm

 

≤ 45 cm≤ 45 cm

Opening size for 20cminsulation thickness

  

≤ 45 cm≤ 50 cm

 

≤ 45 cm≤ 50 cm

 

≤ 45 cm≤ 45 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

38

Fire protection foam PYROSIT® NG Installations

Cable

 Ø 80 mm  

 

Pipe bundle of electrical installation pipes

 Ø 80 mm  

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

Ø 16 mm 

 

Individual lines for control purposes

 

 

Cable support systems

Steel profiles 

 

Electrical installation pipe made of plastic, rigid

Ø 40 mm 

 

Metal pipes with path insulation

Steel, stainless steel andcast steel Ø 88.9 mm,copper Ø 88.9 mm

 

 

Electrical installation pipe made of plastic, flexible

Ø 40 mm 

 

Plastic pipes

Ø 50 mm 

 

Special installations

Cables

Ø 24 mm 

 

Open underfloor ducts

Width max. 60 cm,height max. 16 cm  

 

Screed-covered underfloor ducts

Width max. 35 cm,height max. 18 cm  

 

Klimasplit

"Tubolit DuoSplit" & "TubolitSplit" or comparable6.0 mm–22.0 mm

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

39

Fire protection foam PYROSIT® NG

2-component fire protection foam PYROSIT®NG

 

 

 

 

380TypeFBS-S

Contentsml

Weightkg/100 pc.64.600

Item no.7203800

PackPiece1

PYROSIT® NG 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5°C to +30 °C for up to 12 months.

 

PYROSIT® Foam 

 

 

 

380TypeFSU-F

Contentsml

Weightkg/100 pc.63.700

Item no.7203900

PackPiece1

PYROSIT® Foam 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5°C to +30 °C for up to 12 months.

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

40

Fire protection foam PYROSIT® NG 

Mixer pipe set

10 mixing tubes and 5 extension tubes in the set for PYROSIT® NG fire protection foam. 

TypeFBS-M

Weightkg/100 PUs10.000

Item no.7203803

PackPU1

 

 

 

 

Professional cartridge pistol

High-quality 2-component cartridge pistol for use with the PYROSIT® NG fire protection foam. The parallel move-ment of the outlet to the holding grip ensures easy working.

 

TypeFBS-PH

Weightkg/100 pc.120.000

Item no.7203806

PackPiece1

 

 

 

 

Battery-operated cartridge pistol

High-quality, motor-operated 2-component cartridge pistol for use with the PYROSIT® NG fire protection foam.The hard-shell case contains a FBS-PA pistol, a charging device and a rechargeable battery.

 

TypeFBS-PA2

Weightkg/100 pc.560.000

Item no.7203813

PackPiece1

 

 

 

 

Battery

Battery for motor-operated cartridge pistol FBS-PA2. 

3 14.4TypeEA 3-14

CapacityAh

Nom.voltageV

Weightkg/100 pc.56.000

Item no.7203816

PackPiece1

 

 

 

 

Fire protection case

The PYROSIT® NG fire protection case contains all the required products to create foam insulations. The completeset consists of: 3 x FBS-S, 1 x FBS-PH, 6 mixing and 5 extension pipes.

 

TypeFBS-K

Weightkg/100 pc.420.000

Item no.7203809

PackPiece1

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

41

Fire protection foam PYROSIT® NG

Tempering box  

 

 

When squeezing out cartridges, the right temperature is essential. In order to achieve this, a temperature controlbox is recommended.

 

TypeFBS-TB

Weightkg/100 pc.610.100

Item no.7203818

PackPiece1

 

PYROPLUG® Block foam block  

 

 

Soft, permanently elastic foam block for cable and combination insulation. Vertical and transverse installation toachieve different fire resistance classes. Can be combined with the two-component fire protection foam PYROSIT®NG. Can be used in solid ceilings and walls and in light-duty partitions and is approved for many installations. CE-labelled construction product according to ETA-15/0803 for applications with fire resistance periods of up to 120minutes.Details on the applications can be found in the approval documents.Protect the surface of the foam insulation against water in order to guarantee safe expansion in the case of fire.Coating with standard silicone is approved.

 

200x144x60TypeFBA-B200-14

Dimen-sionmm

Weightkg/100 pc.44.800

Item no.7202505

PackPiece4

 

Section insulation for metal pipes  

 

 

Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.

Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks

Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C 

6100 500 30TypeMIW-MA

Lengthmm

Widthmm

Thicknessmm

Weightkg/100 pc.1,010.000

Item no.7202308

PackPiece2

 

Winding wire for path insulation  

 

 

The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.

 

50TypeMIW-TD

Lengthm

Weightkg/100 pc.10.000

Item no.7202309

PackPiece1

 

Cable coil  

 

 

Self-adhesive, intumescent cable protector, 5 mm thick, for the use with large cable diameters and penetratedcable support systems, applicable in PYROPLUG® systems and PYROSIT® NG.

 

5 150TypeFBA-WI

Lengthm

Widthmm

Weightkg/100 pc.384.000

Item no.7202510

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

42

Fire protection foam PYROSIT® NG

  Adhesive tape

Fibre-reinforced, transparent adhesive tape as lining aid for applications with PYROSIT® NG fire protection foamand for universal fix. One roll contains 25 m².

 

25 50TypeSHT

Lengthm

Widthmm

Weightkg/100 pc.12.000

Item no.7202521

PackPiece5

 

 

 

  Calcium silicate plate

Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.

 

500 150 20500 250 301000 250 30

TypeKSI-P1KSI-P2KSI-P3

Dim.Lmm

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.42.000111.000222.000

Item no.720228372029047202912

PackPiece111

 

 

L

BD

 

  Identification plate

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

 

100

70

25

Ø 7

85

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

43

PYROPLUG® Block System description

 

 

The OBO PYROPLUG® Block combination insula-tion is created from foam blocks, which, if there isa fire, expand without any noticeable pressurecreation. In so doing, they form an insulating car-bon foam. This reliably prevents the penetration offire and smoke through the cable insulation. Com-bustible pipes can be run in this insulation without

an additional sleeve. Copper and steel pipes canbe insulated either with or without section insula-tion. All the PYROPLUG® Block insulation is com-pletely dust and fibre-free. This also applies to anyinstallations at a later date. This is an aspect whichis particularly important for installation in IT andlaboratory rooms.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

44

PYROPLUG® Block Installation principle

Mounting of the cut blocks. 

Vacuum blocks for simple resi-dual gap closing. 

Simple retroinstallation throughremoval of individual blocks. 

Running of combustible pipeswithout additional measures. 

Run-through, non-combustiblepipes with section insulation. 

Tight-fitting installation of theblocks in the ceiling penetration. 

Cut thin strips for the duct com-partments. 

Close the joints and spandrelsbetween the installed cables andthe blocks with a layer of theFBA-SP fire protection compoundof at least 2 cm deep.  

Close the residual joints betweencables and blocks with the FBA-SP filler. 

Classification to DIN

    

     

Classification to EN

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

45

PYROPLUG® Block Registration data

Combination insulation in walls/ceilingsFire resistance class EI 15, EI 30, EI 45, EI 60, EI 90, EI 120

Proof of application European Technical Assessment of OIB, Vienna

Approval number ETA-15/0803

Testing standard EN 1366-3 

Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-001/2012

Air permeation/pressure resistance ift Rosenheim, 11-003694-PR02

Noise insulation HfT Stuttgart, 122-007-04P-186a 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm (EI 30 / EI 60 / EI 90/ EI 120)

10 cm (EI 30 / EI 60 / EI 90/ EI 120)

15 cm (EI 30 / EI 60 / EI 90/ EI 120)

Min. insulation thickness 

14.4 cm  (EI 30 / EI 60)20 cm (EI 90 / EI 120)

14.4 cm  (EI 30 / EI 60)20 cm (EI 90 / EI 120)

14.4 cm  (EI 30 / EI 60)20 cm (EI 90 / EI 120)

Opening size for 14.4 cminsulation thickness

 

 

≤ 100 cm≤ 60 cm

 

≤ 100 cm≤ 60 cm

 

≤ 37.5 cmUnlimited

≤ 40 cm≤ 60 cm

 

≤ 60 cm≤ 100 cm

 

≤ 60 cm≤ 100 cm

 

≤ 100 cm≤ 60 cm

≤ 45 cm≤ 225 cm

Opening size for 20cminsulation thickness

 

 

≤ 100 cm≤ 60 cm

 

≤ 100 cm≤ 60 cm

 

≤ 37.5 cmUnlimited

≤ 40 cmUnlimited

 

≤ 60 cm≤ 100 cm

 

≤ 60 cm≤ 100 cm

 

≤ 60 cm≤ 130 cm

≤ 70 cm≤ 100 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

46

PYROPLUG® Block Installations

Cable

Ø 80 mm 

 

Pipe bundle of electrical installation pipes

Ø 80 mm cable,pipes max. Ø 40 mm  

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

Ø 16 mm 

 

Individual lines for control purposes

 

 

Cable support systems

Steel profiles 

 

Electrical installation pipe made of plastic, rigid

Ø 40 mm 

 

Metal pipes with path insulation

Steel, stainless steel andcast steel Ø 88.9 mm,copper Ø 88.9 mm

 

 

Electrical installation pipe made of plastic, flexible

Ø 40 mm 

 

Plastic pipes

Ø 50 mm 

 

Special installations

Cables

Ø 24 mm 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

47

PYROPLUG® Peg foam series System description

 

 

The PYROPLUG® Peg system from OBO is used tocreate cable insulation with fire protection foamplugs. The foam plugs are ideal for closing coredrill holes in solid walls and concrete ceilings. Thefoam plugs are made of permanently elastic, clo-sed-pore foam, which expands in the event of firewithout any significant pressure build-up, thus crea-ting an insulating plastic foam. This reliably pre-

vents the penetration of fire and smoke through thecable insulation. The PYROPLUG® Peg insulationsystem can be used without difficulty in areas ofdata processing and in laboratories, as mounting iscompletely clean and is free or dust and fibres.This also applies to any necessary cable installati-ons at a later date. Special tools are not requiredfor processing, a knife is sufficient.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

48

PYROPLUG® Peg foam series Installation principle

Ideal  for core drill holes of55 mm to 240 mm. 

Cutting of the plugs for cableassignment on the edge of thecore hole. 

Push cut plugs into the core hole. 

Due to the elastically material aquick mounting is possible. 

Cutting and mounting of the plugsin ceilings. 

Residual joints are closed off withthe filler FBA-SP. 

Small distance to next core drillhole possible. 

With retroinstallations, carefullycut or drill the plugs. 

Classification to DIN

    

     

Classification to EN

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

49

PYROPLUG® Peg foam series Registration data

Combination insulation in walls/ceilingsFire resistance class EI 30, EI 45, EI 60, EI 90, EI 120

Proof of application European Technical Assessment of OIB, Vienna

Approval number ETA-15/0701

Testing standard EN 1366-3 

Additive proofsHeat permeation Fraunhofer IBP Stuttgart, P1-001/2012

Air permeation/pressure resistance ift Rosenheim, 11-003694-PR01

Noise insulation HfT Stuttgart, 122-007-04P-186a 

Installation locationsInsulation in walls and ceilings

Component F30 Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)

10 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)

15 cm (EI 30 / EI 60 / EI 90)20 cm (EI 90 / EI 120)

Min. insulation thickness 

>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)

>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)

>17 cm‒<20 cm (EI 30 / EI60 / EI 90)20 cm (EI 90 / EI 120)

Opening size

 

Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm

Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm

Ø 55 mm, Ø 68 mm,Ø 97 mm, Ø 112 mm,Ø 124 mm, Ø 155 mm,Ø 190 mm, Ø 240 mm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

50

PYROPLUG® Peg foam series Installations

Cable

Ø 80 mm 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

Ø 16 mm 

 

Individual lines for control purposes

 

 

Cable support systems

Steel profiles 

 

Electrical installation pipe made of plastic, rigid

Ø 16 mm 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

Ø 16 mm 

 

Plastic pipes

 

 

Special installations

Cables

Ø 24 mm 

 

Insulation in the lining pipe

PE-HD pipe(ceiling)  

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

51

PYROPLUG® Box box insulationSystem description

 

 

The PYROPLUG® Box system from OBO is used tocreate cable insulation with boxes made of foam.The system is particularly suitable for simple moun-ting of cable insulation in light-duty partitions. Nolayering is required. Installation in solid walls andsolid ceilings is also possible and approved. Theinsulation system consists of a two-part frame andtwo matching internal pieces. The permanently ela-

stic, closed-pore foam material expands in theevent of fire without any significant pressure build-up, thus creating an insulating plastic foam. Thisreliably prevents the penetration of fire and smokethrough the cable insulation. The usable area of theboxes corresponds to the maximum approval cableassignment area of 60%. It is thus impossible toover assign it with cables.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

52

PYROPLUG® Box box insulationInstallation principle

Insertion of the split frame in light-duty partitions, without additionallayering.  

Mounting of the frame with pre-viously installed cables. 

Exact cutting of the internal pie-ces and then insertion in theframe. 

Closing joint component on fullassignment with FBA-SP filler. 

Grouped arrangement of theboxes. 

Classification to DIN

    

     

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

53

PYROPLUG® Box box insulationRegistration data

Insulation in wall/ceilingFire resistance class S30, S60, S90

Proof of application General construction approval of DIBt, Berlin

Approval number Z-19. 15-1557

Testing standard DIN 4102 Part 9 

Installation locationsInsulation in walls and ceilings

Component F30 Rigid walls Flexible walls Rigid floors

     

Min. component strength 

5 cm(S30 / S60 / S90)

7.5 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

20 cm(S30 / S60 / S90)

20 cm(S30 / S60 / S90)

20 cm(S30 / S60 / S90)

Opening size 

 

≤ 50 cm≤ 50 cm

 

≤ 50 cm≤ 50 cm

 

≤ 50 cm≤ 50 cm

Component F90 Screed-covered

Rigid walls

Flexible walls Rigid floors

     

Min. component strength 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

20 cm(S30 / S60 / S90)

20 cm(S30 / S60 / S90)

20 cm(S30 / S60 / S90)

Opening size 

 

≤ 50 cm≤ 50 cm

 

≤ 50 cm≤ 50 cm

 

≤ 50 cm≤ 50 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

54

PYROPLUG® Box box insulationInstallations

Cable

All Ø 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

Ø 100 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

Ø 15 mm 

 

Cable support systems

Profiles made of steel, alumi-nium or plastic  

 

Electrical installation pipe made of plastic, rigid

Ø 20 mm 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

Ø 20 mm 

 

Plastic pipes

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

55

PYROPLUG® Shell pipe shellsSystem description

 

 

The OBO PYROPLUG® Shell system is speciallydesigned for cable insulation in box drill holes inlight-duty partitions. The insulation system consistsof a pipe shell and two matching plugs. The mate-rial is made of permanently elastic, closed-porefoam, which expands in the event of fire withoutany significant pressure build-up, thus creating an

insulating plastic foam. This reliably prevents thepenetration of fire and smoke through the cableinsulation. The ratio of the external diameter to theinternal diameter of the pipe shell ensures that overassignment with cables is not possible, even at fullassignment.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

56

PYROPLUG® Shell pipe shellsInstallation principle

Drilling of a hole with a drillcrown. 

Grouped arrangement of the drillholes. 

Insertion of the pipe shell in thelight-duty partition. 

For previously installed cables,cutting of the pipe shell. 

Cutting and insertion of the plugsin the pipe shell. 

Full assignment of the pipe shell. 

Classification to DIN

    

     

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

57

PYROPLUG® Shell pipe shellsRegistration data

Insulation in wall / ceilingFire resistance class S30, S60, S90

Proof of application General construction approval of DIBt, Berlin

Approval number Z-19. 15-1559

Testing standard DIN 4102 Part 9 

Installation locationsInsulation in walls and ceilings

Component F30 Rigid walls Flexible walls Rigid floors

     

Min. component strength 

5 cm(S30 / S60 / S90)

7.5 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

Opening size 

≤ Ø 10 cm ≤ Ø 10 cm ≤ Ø 10 cm

Component F90 Screed-covered

Rigid walls

Flexible walls Rigid floors

     

Min. component strength

 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

Opening size 

≤ Ø 10 cm ≤ Ø 10 cm ≤ Ø 10 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

58

PYROPLUG® Shell pipe shellsInstallations

Cable

All Ø 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

 

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

Ø 15 mm 

 

Cable support systems

Profiles made of steel, alumi-nium or plastic  

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

 

 

Plastic pipes

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

59

PYROPLUG® Mini filler System description

 

 

The OBO PYROPLUG® Mini system is ideal forsmall, round cable insulations up to a diameter of8  cm. It only consists of the one-component fillerPYROPLUG® Screed. In light-duty partitions, the

empty mini pipe shell of the PYROPLUG® Shell sys-tem is used as layering. The interior of these pipeshells may be completely assigned. Only the resi-dual joints must be filled with the filler.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

60

PYROPLUG® Mini filler Installation principle

Closing of the opening with the fil-ler FBA-SP. 

In light-duty partitions, use of themini pipe shell FBA-DR. 

Complete assignment of the minipipe shell. 

Classification to DIN

    

     

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

61

PYROPLUG® Mini filler Registration data

Insulation in wall/ceilingFire resistance class S30, S60, S90

Proof of application General construction approval of DIBt, Berlin

Approval number Z-19. 15-1851

Testing standard DIN 4102 Part 9 

Installation locationsInsulation in walls and ceilings

Component F90 Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

10 cm(S30 / S60 / S90)

10 cm(S30 / S60 / S90)

15 cm(S30 / S60 / S90)

Opening size 

≤ Ø 8 cm ≤ Ø 8 cm ≤ Ø 8 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

62

PYROPLUG® Mini filler Installations

Cable

Ø 18 mm 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

 

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

 

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

 

 

Plastic pipes

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

63

PYROPLUG® foam series

PYROPLUG® Block foam block  

 

 

Soft, permanently elastic foam block for cable and combination insulation. Vertical and transverse installation toachieve different fire resistance classes. Can be combined with the two-component fire protection foam PYROSIT®NG. Can be used in solid ceilings and walls and in light-duty partitions and is approved for many installations. CE-labelled construction product according to ETA-15/0803 for applications with fire resistance periods of up to 120minutes.Details on the applications can be found in the approval documents.Protect the surface of the foam insulation against water in order to guarantee safe expansion in the case of fire.Coating with standard silicone is approved.

 

200x144x60TypeFBA-B200-14

Dimen-sionmm

Weightkg/100 pc.44.800

Item no.7202505

PackPiece4

 

PYROSIT® Blocks 

 

 

Foam block for cable and combination insulation in accordance with UL listings. Also approved in combination withthe fire protection foam PYROSIT® foam.The block contains a glass fabric for stabilisation in the event of fire, meaning that no additional measures are requi-red on the insulation surface, e.g. protective mesh.

 

200x130x60TypeFSU-B7.9

Dimen-sionmm

Weightkg/100 pc.55.000

Item no.7203903

PackPiece4

 

PYROPLUG® Block vacuum block  

 

 

Vacuum-packed version of the FBA-B200-14 foam block for the simple closure of the residual gap in thePYROPLUG® Block combination insulation. After mounting has been completed, the film is cut and the blockexpands to its original size again. The film can remain in the insulation.

 

200x144x25TypeFBA-BV200-14

Dimen-sionmm

Weightkg/100 pc.40.000

Item no.7202515

PackPiece1

 

2-component fire protection foam PYROSIT®NG

 

 

 

PYROSIT® NG 2-component fire protection foam in a cartridge, including 2 mixing tubes.To create cable and combination insulation; always process with the cartridge pistols FBS-PH or FBS-PA.In dry, frost-free rooms, the cartridge can be stored closed and standing upright at temperatures from +5 °C to +30°C for up to 12 months.

 

380TypeFBS-S

Contentsml

Weightkg/100 pc.64.600

Item no.7203800

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

64

PYROPLUG® foam series

  PYROPLUG® Peg plugs

Plug for cable insulationProtect the FBA plugs against water in order to guarantee safe foaming in case of fire.

 

55 - 65 75 6568 - 78 87 7897 - 107 117 107112 - 122 132 122124 - 134 144 134155 - 165 175 165190 - 200 210 200240 - 250 260 250

TypeFBA-SN65FBA-SN78FBA-SN107FBA-SN122FBA-SN134FBA-SN165FBA-SN200FBA-SN250

ForopeningØ mm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.8.20012.60021.60028.60032.90049.70074.400101.400

Item no.72025537202557720256172025657202569720257372025777202581

PackPiece44444222

 

 

 

 

PYROSIT® Plugs

Plug for cable insulationProtect the FBA plugs against water in order to guarantee safe foaming in case of fire.

 

63 6576 78101 107114 122127 134

TypeFSU-P2.5FSU-P3FSU-P4FSU-P4.5FSU-P5

ForopeningØ mm

Dim. Dmm

Weightkg/100 pc.14.50018.70033.00043.00049.500

Item no.72039097203912720391572039197203921

PackPiece44444

 

 

 

  PYROPLUG® Box box insulation

Box for cable insulation.Consisting of a two-part, hard frame and two soft internal pieces. Protect the frame and internal pieces againstwater in order to guarantee safe foaming in case of fire.

 

200x200x100TypeFBA-F

Dimen-sionmm

Weightkg/100 pc.122.000

Item no.7202660

PackPiece1

 

 

200200170

200

10040

 

  PYROPLUG® Shell drill crown insulation

Pipe shell for cable insulationConsisting of a one-part, hard pipe sleeve and two soft plugs of 50 mm diameter. Protect the pipe sleeves andplugs against water in order to guarantee safe foaming in case of fire.

 

100150

TypeFBA-D100FBA-D150

Dim.Lmm

Weightkg/100 pc.15.50019.200

Item no.72026247202628

PackPiece11

 

 

 

  Empty mini pipe shell

Empty pipe sleeve for use in FBA-SP small insulation in lightweight partitions.Protect the pipe sleeves against water in order to guarantee safe foaming in case of fire.

 

100150

TypeFBA-DR100FBA-DR150

Dim.Lmm

Weightkg/100 pc.6.50010.200

Item no.72026137202617

PackPiece11

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

65

PYROPLUG® foam series

PYROPLUG® screed filler  

 

 

Fire protection filler in a cartridge.Usable as small insulation and as joint closing compound in all insulation of the PYROPLUG® series.In dry, frost-free rooms, the fire protection filler can be stored for up to 12 months at a temperature of +5 °C to +30°C.

 

310TypeFBA-SP

Contentsml

Weightkg/100 pc.46.000

Item no.7202322

PackPiece1

 

PYROSIT® Sealant 

 

 

Fire protection filler in a cartridge.Fire protection filler in a cartridge as joint closing compound in accordance with UL listings.In dry, frost-free rooms, the fire protection filler can be stored for up to 12 months at a temperature of +5 °C to +30°C.

 

310TypeFSU-M

Contentsml

Weightkg/100 pc.50.000

Item no.7203906

PackPiece1

 

Steel wire grid  

 

 

Steel wire grid as support and protection grid, wire diameter 4 mm. 

600 5001000 600

TypeSDG-1SDG-2

Dim.Lmm

Dim. Bmm

Weightkg/100 pc.135.000270.000

Item no.72029637202971

PackPiece11

 

MMS-plus MS mounting rail tie, with flat pan-head

 

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx

TypeMMS+ MS 7.5x50MMS+ MS 7.5x60

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Weightkg/100 pc.1.5001.800

Item no.34982613498262

PackPiece10050

 

Section insulation for metal pipes  

 

 

Mineral wool mats with aluminium lamination for section insulation on copper and steel pipes. Fastening with win-ding wire, securing of joints with aluminium adhesive tape.

Applicable in the systems:PYROMIX® mortar insulationPYROSIT® NG fire insulation foamPYROPLATE® Fibre soft insulationPYROPLUG® Block blocks

Material class EN 13501 - A1 non-combustible; melting point ≥ 1,000 °C 

6100 500 30TypeMIW-MA

Lengthmm

Widthmm

Thicknessmm

Weightkg/100 pc.1,010.000

Item no.7202308

PackPiece2

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

66

PYROPLUG® foam series 

Aluminium adhesive tape for path insulation

Aluminium adhesive tape for applying the aluminium-laminated section insulation. The aluminium adhesive tape isself-adhesive and not classified as combustible according to DIN 4102-1.

 

100 100TypeMIW-AT

Lengthm

Widthmm

Weightkg/100 pc.136.900

Item no.7202305

PackPiece1

 

 

 

  Winding wire for path insulation

The steel wire is used to fix the section insulation. It is non-combustible and guarantees optimum retention of thesection insulation on non-combustible pipes and cables.

 

50TypeMIW-TD

Lengthm

Weightkg/100 pc.10.000

Item no.7202309

PackPiece1

 

 

 

  Cable coil

Self-adhesive, intumescent cable protector, 5 mm thick, for the use with large cable diameters and penetratedcable support systems, applicable in PYROPLUG® systems and PYROSIT® NG.

 

5 150TypeFBA-WI

Lengthm

Widthmm

Weightkg/100 pc.384.000

Item no.7202510

PackPiece1

 

 

 

  Calcium silicate plate

Calcium silicate plate, as support plate, for the construction of frames in the penetration and to double thin wallthicknesses.Materials class EN 13501 - A1 non-combustible.

 

500 150 20500 250 301000 250 30

TypeKSI-P1KSI-P2KSI-P3

Dim.Lmm

Dim. Bmm

Dim. Dmm

Weightkg/100 pc.42.000111.000222.000

Item no.720228372029047202912

PackPiece111

 

 

L

BD

 

  Identification plate

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanEnglishSwedishSpanishEnglishCroatian

TypeKS-S DEFSU-IPKS-S SEKS-S ESKS-S ENKS-S HR

Language Weightkg/100 pc.2.4002.0002.4002.4002.4002.400

Item no.720542572039247205426720542772054297205438

PackPiece1101111

 

 

100

70

25

Ø 7

85

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

67

PYROCOMB® pipe sleeveSystem description

 

 

The PYROCOMB® system can be used as indepen-dent pipe sealing for combustible pipes (e.g. sani-tary wastewater pipes). It is primarily made up ofthe pipe sleeves, type TCX. In the event of fire, thefire protection material inserted within the sealfoams up after a few minutes under high pressure,closing the soft plastic pipes. This safely prevents

the spread of fire and smoke, should a fire occur.With wall mounting, the pipe sleeves are mountedon both sides of the wall with metal anchors. Cei-ling penetrations only have a tube seal from theunderside. In light-duty partitions, the pipe sleevesare fastened on passed-through threaded rods andconnected together.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

68

PYROCOMB® pipe sleeveInstallation principle

Two-sided arrangement of thepipe sleeves for wall mounting. 

Mounting on the underside of theceiling with metal anchors. 

Sloping pipe penetration up to anangle of 39°. 

Pipe sleeves in the area of thepenetration. 

Eccentric arrangement with max.3 levels of larger pipe sleeves. 

Pipe post systems with 2 accom-panying cables. 

Classification to DIN

    

     

Classification to EN

               

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

69

PYROCOMB® pipe sleeveRegistration data

Pipe insulation in underfloor ductsFire resistance class El 15, El 30, El 45, El 60, El 90, El 120, El 180, El 240

Proof of application General construction approval of OIB, Vienna

Approval number ETA-12/0182

Testing standard EN 1366-3 

Installation locationsPipe insulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm (EI 30 / EI 60 / EI 90/ EI 120 / EI 240)

10 cm (EI 30 / EI 60 / EI 90/ EI 120)

15 cm (EI 30 / EI 60 / EI 90/ EI 120)30 cm (EI 180 / EI 240)

Min. insulation thickness 

10 cm (EI 30 / EI 60 / EI 90/ EI 120 / EI 240)

10 cm (EI 60 / EI 90 / EI120)

15 cm (EI 30 / EI 60 / EI 90/ EI 120)30 cm (EI 180 / EI 240)

Opening size 

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm,Ø 140 mm, Ø 160 mm,Ø 180 mm, Ø 200 mm,Ø 225 mm, Ø 250 mm,Ø 280 mm, Ø 300 mm,Ø 315 mm, Ø 355 mm,Ø 400 mm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

70

PYROCOMB® pipe sleeveInstallations

Cable

 

 

Pipe bundle of electrical installation pipes

 

 

Cable bundle

 

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

 

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

 

 

Plastic pipes

Ø 400 mm 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

71

PYROCOMB® Tubes pipe sleeve System description

 

 

The PYROCOMB® Tubes system is used to createcable insulation with pipe sleeves. The systemcomprises multiple sizes of the pipe sleeve, typeTCX. This allows simple insulation of bundles ofplastic electrical installation pipes, rigid or flexible,up to a size of M63. It is irrelevant whether the

pipes are filled with cables or are empty. In theevent of fire, the fire protection material insertedwithin the seal foams up after a few minutes underhigh pressure, closing the softened bundles at ahigh pressure. This safely prevents the spread offire and smoke, should a fire occur.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

72

PYROCOMB® Tubes pipe sleeve Installation principle

Two-sided arrangement of thepipe sleeves for wall mounting. 

Mounting on the underside of theceiling with metal anchors. 

Closing of the ring gap with theinsulation layer creator DSX. 

Combination of the sleeve halvesand fastening on the wall. 

Closing of the pipe ends with theinsulation layer creator DSX. 

Labelled insulation of installationpipe bundles. 

Classification to DIN

    

     

Classification to EN

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

73

PYROCOMB® Tubes pipe sleeve Registration data

Combination insulation in walls and ceilingsFire resistance class El 15, El 30, El 45, El 60, El 90, El 120

Proof of application General construction approval of OIB, Vienna

Approval number ETA-12/0207

Testing standard EN 1366-3 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm (EI 30 / EI 60 / EI 90/ EI 120)

10 cm (EI 30 / EI 60 / EI 90/ EI 120)

15 cm (EI 30 / EI 60 / EI 90/ EI 120)

Min. insulation thickness 

10 cm (EI 60 / EI 90 / EI120)

10 cm (EI 60 / EI 90 / EI120)

15 cm (EI 60 / EI 90 / EI120)

Opening size

 

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm

Ø 32 mm, Ø 40 mm,Ø 50 mm, Ø 63 mm,Ø 75 mm, Ø 90 mm,Ø 110 mm, Ø 125 mm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

74

PYROCOMB® Tubes pipe sleeve Installations

Cable

 

 

Pipe bundle of electrical installation pipes

Ø 125 mm 

 

Cable bundle

 

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

 

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

Ø 63 mm,cable Ø 21 mm  

 

Plastic pipes

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

75

PYROCOMB® pipe sleeve

Pipe sleeve with 2 fastening straps  

 

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M6 threaded rods.

 

32 - 34 26 50 3640 - 42 26 58 4450 - 52 26 68 54

TypeTCX-032TCX-040TCX-050

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.6.5007.0008.000

Item no.720220072022017202203

PackPiece111

 

Pipe sleeve with 4 fastening straps  

 

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors of M6 threaded rods up to size 75 mm, then M8.

 

63 - 65 26 94 6775 - 77 26 106 7990 - 92 26.6 132 94110 - 112 26.6 155 114125 - 127 40 172 129

TypeTCX-063TCX-075TCX-090TCX-110TCX-125

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.15.50019.00037.00046.00070.000

Item no.72022047202205720220672022077202208

PackPiece11111

 

Pipe sleeve with 6 fastening straps  

 

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

140 - 142 40 200 144160 - 162 40 220 164

TypeTCX-140TCX-160

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.106.000107.000

Item no.72022097202210

PackPiece11

 

Pipe sleeve with 8 fastening straps  

 

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

180 - 182 40 264 184200 - 202 40 284 204

TypeTCX-180TCX-200

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.175.000242.000

Item no.72022127202214

PackPiece11

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

76

PYROCOMB® pipe sleeve

  Pipe sleeve with 10 fastening straps

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

225 - 227 51.5 328 239250 - 252 51.5 353 264

TypeTCX-225TCX-250

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.306.000346.000

Item no.72022137202215

PackPiece11

 

  Pipe sleeve with 12 fastening straps

 

 

Pipe sleeve for combustible pipes.If there is a fire, fire protection inserts inside the sheet steel housing expand, exerting a verygreat pressure onto the burning thermoplastic pipes.Fastening with anchors or M8 threaded rods.

 

280 - 282 51.5 378 289300 - 302 51.5 403 314315 - 317 51.5 417 328355 - 357 51.5 459 370400 - 402 51.5 504 415

TypeTCX-280TCX-300TCX-315TCX-355TCX-400

PipeØmm

Dim. hmm

Dim. Dmm

Dim.dmm

Weightkg/100 pc.398.000405.000425.000460.000520.000

Item no.72022167202217720221872022197202220

PackPiece11111

 

  Insulation layer creator in a cartridge

Dispersion-based fire protection compound for interior areas, to fill residual joints and close openings. Approvedmaterial for the closing of core drill holes when feeding through single cables and for closing the annular gap whenexiting cables from the PYROLINE® Con PLC fire protection duct. Material class DIN 4102 - B2, normally flam-mable. In dry, frost-free rooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.

 

300TypeDSX-K

Contentsml

Weightkg/100 pc.50.000

Item no.7202300

PackPiece1

 

 

 

  Threaded rod

Threaded rod to DIN 976. 

M6 6 1000M8 8 1000

TypeTR M6 1M GTR M8 1M G

Thread

Dim.dmm

Dim.Lmm

Weightkg/100 pc.18.30030.000

Item no.31410473141128

PackPiece1010

 

 

 

  Hexagonal nut DIN 934

Hexagonal nut to DIN 934 with metric thread. 

M6 10 5.2 6M8 13 6.8 8

TypeHN M6 GHN M8 G

ThreadSWmm

Dim. hmm

Dim.dmm

Weightkg/100 pc.0.2210.500

Item no.34000693400085

PackPiece100100

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

77

PYROCOMB® pipe sleeve

Washer ISO 7093  

 

 

Washer of large outer diameter for universal use. 

M6 6.5 28 2.5M8 8.5 28 2.5

TypeWS M6 D28 GWS M8 D28 G

Thread

Dim.dmm

Dim. Dmm

Dim. hmm

Weightkg/100 pc.1.1041.100

Item no.34022073402215

PackPiece100100

 

MMS-plus P round head tie, with panhead  

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With roundhead for universal fastenings. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

6 x 50 5 11.2 Torx 50TypeMMS+ P 6x50

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Dim.Lmm

Weightkg/100 pc.1.000

Item no.3498108

PackPiece100

 

MMS-plus MS mounting rail tie, with flat pan-head

 

 

 

Bolt tie for direct mounting without additional anchors in cracked and uncracked concrete and masonry. With largeround head to fasten mounting and profile rails. Torx drive T30.Construction product tested according to EAD and CE mark, with European Technical Assessment (ETA) andproof of suitability. Load-bearing capacities under fire loads proven up to fire resistance class R120.

 

7,5 x 50 6 17 Torx7,5 x 60 6 17 Torx

TypeMMS+ MS 7.5x50MMS+ MS 7.5x60

Dimen-sionmm

DrillholeØmm

Head Ømm

Screw system

Weightkg/100 pc.1.5001.800

Item no.34982613498262

PackPiece10050

 

Nail anchor N with thread  

 

L

 

The nail anchor N can be used for multiple fastenings of non-load-bearing systems and in cracked and non-cracked concrete, thereby combining the benefits of a bolt tie with even easier mounting.The nail tie only needs to be hammered into the drill hole. It is not necessary to apply torque subsequently. Whenthe load occurs, the nail tie spreads itself and bolts itself in the drill hole.

 

M6 6 5 - 10 49TypeN 6-5-10/49

Thread

DrillholeØmm

Clampingrangemm

Dim.Lmm

Weightkg/100 pc.1.160

Item no.3498396

PackPiece100

 

Bolt tie BZ-U  

 

 

Bolt tie BZ for the anchoring of medium-duty to heavy-duty loads, both in cracked and non-cracked concrete. Itcombines high approved loads with small edge distances and axial spacings.

 

M8 75TypeBZ-U 8-10-21/75

Thread

Dim.Lmm

Weightkg/100 pc.3.460

Item no.3498320

PackPiece50

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

78

PYROCOMB® pipe sleeve

  Mineral wool

Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.

 

25 LiterTypeMIW-S

Dimension Weightkg/100 pc.250.000

Item no.7202306

PackPiece1

 

 

 

  Identification plate

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

 

100

70

25

Ø 7

85

 

  Support construction for insulations, withbracket

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.

 

70 217 50TypeSKA 05 VZ

Dim.Hmm

Dim. Bmm

Dim.Amm

Weightkg/100 pc.190.740

Item no.7202436

PackPiece1

 

 

 

  Support construction for insulations, with pen-dulum suspension

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.

 

1000TypeSKP 05 VZ

Dim.Lmm

Weightkg/100 pc.235.240

Item no.7202446

PackPiece1

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

79

PYROCOMB® Intube pipe shellSystem description

 

 

The PYROCOMB® Intube system is used to createcable insulation with pipe shells or half shells. Thepipe shell is particularly suitable for core drill holesand can very easily be installed in solid ceilings orwalls and also light-duty partitions. For this, two halfpipe sleeves are clicked together and bedded inmortar in the core hole. Then the pipe sleeves areclosed with seals and the surface is sealed withASX ablation coating. The cables don't require any

coating. The half shell can be used particularly wellin the underfloor area. It is sealed on one side withfire protection plugs and sealed with ASX ablationcoating. In case of a fire, the inner coating of thepipe shell or the half shell expands and, in sodoing, closes the opening cross-section comple-tely. The transfer of fire and smoke is thus safelyprevented. With the PYROCOMB® Intube system,100% assignment of the interior is possible.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

80

PYROCOMB® Intube pipe shellInstallation principle

Mounting of the pipe shell byclicking the half shells togetheraround the existing installation.  

Closing of the opening withPYROMIX® mortar.  

Adjust the foam plugs to installati-ons using a knife and createsmoke gas-tight sealing of thesealings using the ASX coatingcompound.  

With ceiling mounting, use a linedbody to prevent the pipe shellfrom falling out. 

In certain applications, securitywith metal tensioning straps inlight-duty partitions is necessary.  

Pipe shells with full assignmentwith cable bundles and electricalinstallation pipes.  

Mounting of the half shell. 

Adjusting the foam plug to thecables. 

Fully installed half shell inPYROPLATE® Fibre soft insula-tion.  

Classification to DIN

           

           

 

Erectors of combination insulation require training.Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

81

PYROCOMB® Intube pipe shellRegistration data

Insulation in wall/ceilingFire resistance class El 60, El 90, El 120

Proof of application General construction approval of OIB, Vienna

Approval number ETA - 13/0904

Testing standard EN 1366-3 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150

10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150

12.5 cm(EI 30 / EI 45 / EI 60)CTS-150

15 cm - 30 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

10 cm - 15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

Min. insulation thickness 

10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150

10 cm - 15 cm(EI 30 / EI 60 / EI 90)CTS-150

12.5 cm(EI 30 / EI 45 / EI 60)CTS-150

15 cm - 30 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

10 cm - 15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

15 cm(EI 30 / EI 60 / EI 90 /EI 120) CTS-300

Opening size 

Ø 125 mm Ø 125 mm Ø 125 mm

 

55 mm x 116 mm 55 mm x 116 mm 55 mm x 116 mm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

82

PYROCOMB® Intube pipe shellInstallations

Cable

Ø 80 mm 

 

Pipe bundle of electrical installation pipes

Ø 107 mm 

 

Cable bundle

Ø 107 mm,cable Ø 21 mm  

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

 

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

Ø 32 mm,cable Ø 21 mm  

 

Plastic pipes

2 × Ø 32 mm 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

83

Pipe shell PYROCOMB® Intube

PYROCOMB® Intube pipe shell, Ø 60 mm  

 

 

Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.

 

150 60 50.6 65TypeCTS 06150

Dim.Lmm

Dim. Bmm

Dim. Dmm

ForopeningØ mm

Weightkg/100 pc.17.500

Item no.7204290

PackPiece1

 

PYROCOMB® Intube pipe shell, Ø 90 mm  

 

 

Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.

 

150 90 80.6 100300 90 80.6 100

TypeCTS 09150CTS 09300

Dim.Lmm

Dim. Bmm

Dim. Dmm

ForopeningØ mm

Weightkg/100 pc.27.50054.000

Item no.72042927204296

PackPiece11

 

PYROCOMB® Intube pipe shell, Ø 120 mm  

 

 

Internally coated pipe shells with click lock. The inner space can be fitted with cables and electrical installation pipescompletely. CE-labelled, European approved construction product according to ETA-13/0904 and German generaltype approval. Fire resistance up to 120 minutes.Closing with 2 foam plugs included in the delivery. The surface seal is created with PYROCOAT® ASX coating.In some applications, the use of metallic tightening straps is prescribed to secure the pipe shells in light-duty parti-tions. Details can be found in the mounting instructions/approval.

 

150 116.4 107 125300 116.4 107 125

TypeCTS 12150CTS 12300

Dim.Lmm

Dim. Bmm

Dim. Dmm

ForopeningØ mm

Weightkg/100 pc.35.20070.000

Item no.72043007204304

PackPiece11

 

PYROCOMB® Intube half shell  

 

 

Internally coated half shell, the inner space of which can be fully assigned with cables and electrical installationpipes. CE-labelled, European approved construction product according to ETA-13/0904 and German general typeapproval. Fire resistance up to 120 minutes.Closing with foam plug included in the delivery. The surface seal is created with PYROCOAT® ASX coating. Thesystem is particularly suitable for underfloor areas.Details can be found in the mounting instructions/approval.

 

106 200 118TypeCTS-HP200

Dim. Dmm

Dim.Lmm

Dim. Bmm

Weightkg/100 pc.20.000

Item no.7204306

PackPiece1

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

84

Pipe shell PYROCOMB® Intube

  Ablation coating PYROCOAT® in a cartridge

Combined, endothermic and weatherproof coating for internal and external areas. Universal protection coating forcable and cable support structures. Use as direct filler, and as paint when stirred.Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.

 

310TypeASX-K

Contentsml

Weightkg/100 pc.50.000

Item no.7202310

PackPiece1

 

 

 

  Ablation coating PYROCOAT® in a bucket

Combined, endothermic and weatherproof coating for internal and external areas. Universal protection coating forcable and cable support structures. Use as direct filler, and as paint when stirred. Sufficient for an area of 4 m².Material class DIN 4102 - B2, normally flammable.In dry, frost-free rooms, the coating can be stored at temperatures from +5 °C to +25 °C for up to 18 months inclosed, upright original containers.

 

5TypeASX-E

Contentskg

Weightkg/100 pc.500.000

Item no.7202312

PackPiece1

 

 

 

  PYROMIX® dry mortar in bucket

Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pressing and formanual installation. Adding approx. 3 litres of water to 10 kg of dry mortar produces about 10 litres of workablecompound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.

 

10TypeMSX-E1

Contentskg

Weightkg/100 pc.1,000.000

Item no.7206058

PackPiece1

 

 

 

  PYROMIX® dry mortar in paper sack

Mortar to create cable and combination insulation in solid walls and ceilings. Suitable for pumping, pressing and formanual installation. Adding approx. 6 litres of water to 20 kg of dry mortar produces about 20 litres of workablecompound.In dry, frost-free rooms, the dry mortar can be stored for at least 12 months in closed original containers.

 

20TypeMSX-S1

Contentskg

Weightkg/100 pc.2,000.000

Item no.7206104

PackPiece1

 

 

 

  Metal strip clips, narrow

Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing. 

450 7TypeMBS 045

Lengthmm

Widthmm

Weightkg/100 pc.0.602

Item no.7203104

PackPiece50

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

85

Pipe shell PYROCOMB® Intube

Identification plate  

 

100

70

25

Ø 7

85

 

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

86

87

PYROMIX Screed® small insulation System description

 

 

Small insulation for cables is created using thePYROMIX® Screed system. It consists of OBO'sinsulation forming material, type DSX, and the MIWmineral wool. As the insulation basis, the openingis first filled using the non-combustible mineralwool (melting point ≥ 1,000 °C). Then, both sides

of the opening are sealed with the DSX insulationcreator. If there is a fire, the filler foams up, preven-ting penetration by fire and smoke. When the mate-rial foams up, heat is also drawn from the cables,thus considerably reducing the transfer of heat viathe copper cores.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

88

PYROMIX Screed® small insulation Installation principle

Mineral wool with melting point ≥1,000 °C to plug the opening. 

Closure of the surfaces on bothsides with the DSX insulationlayer creator.(Minimum thickness 1  cm oneach side.) 

Labelling of the small insulation. 

Classification to DIN

    

     

           

 

Erectors of combination insulation require training.

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

89

PYROMIX Screed® small insulation Registration data

Insulation in walls/ceilingsFire resistance class S30, S60, S90

Proof of application General type approval of the DIBt, Berlin

Approval number Z-19.53-2314

Testing standard DIN 4102 Part 9 

Installation locationsInsulation in walls and ceilings

Component Rigid walls Flexible walls Rigid floors

     

Min. component strength 

10 cm(S30/S60/S90)

10 cm(S30/S60/S90)

15 cm(S30 / S60 / S90)

Min. insulation thickness 

10/15 cm(S30/S60/S90)

10/15 cm(S30/S60/S90)

15 cm(S30 / S60 / S90)

Opening size 

 

≤ 35 cm≤ 15 cm

 

≤ Ø 15 cm  

≤ 35 cm≤ 15 cm

≤ Ø 15 cm  

≤ 15 cm≤ 15 cm

 

≤ Ø 15 cm

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

90

PYROMIX Screed® small insulation Installations

Cable

All Ø 

 

Pipe bundle of electrical installation pipes

≤ 100 mm ØElR ≤ 32 mm Ø  

 

Cable bundle

≤ 100 mm ØCable ≤ 21 mm Ø  

 

Electrical installation pipe made of steel

 

 

Individual lines for control purposes

 

 

Cable support systems

 

 

Electrical installation pipe made of plastic, rigid

 

 

Metal pipes with path insulation

 

 

Electrical installation pipe made of plastic, flexible

≤ 32 mm Ø 

 

Plastic pipes

 

 

 

Details on the version can be found in the proof of suitability or mounting instructions.All the stated dimensions are maximum values. 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

91

Small insulation, bandage and individual cables acc. to MLAR

Insulation layer creator in a cartridge  

 

 

 

Dispersion-based fire protection compound for interior areas, to fill residual joints and closeopenings. Approved material for the closing of core drill holes when feeding through singlecables and for closing the annular gap when exiting cables from the PYROLINE® Con PLCfire protection duct. Material class DIN 4102 - B2, normally flammable. In dry, frost-freerooms, the compound can be stored at temperatures from +5 °C to +25 °C for up to 18months in closed, upright original containers.

 

300TypeDSX-K

Contentsml

Weightkg/100 pc.50.000

Item no.7202300

PackPiece1

 

Mineral wool  

 

 

 

Universal filling wool for various fire protection applications, packed in compressed form.Material class EN 13 501 - A1, non-combustible; melting point ≥ 1,000 °C.

 

25 LiterTypeMIW-S

Dimension Weightkg/100 pc.250.000

Item no.7202306

PackPiece1

 

Bandage for insulation 

 

 

Fire protection bandage coated with a substance on one side that foams up in the event of fire. It can be used to wrapinstallations in PYROMIX® dry mortar or PYROPLATE® Fibre plate insulations. 

10 125TypeFSB-WB 1.5

Lengthm

Widthmm

Weightkg/100 pc.220.000

Item no.7203163

PackPiece1

 

Identification plate  

 

100

70

25

Ø 7

85

 

Identification plate to be written on with waterproof and light-resistant felt-tip pen for fire-safe cable glands, including2 push-fit anchors.

 

GermanSwedishSpanishEnglishCroatianEnglish

TypeKS-S DEKS-S SEKS-S ESKS-S ENKS-S HRFSU-IP

Language Weightkg/100 pc.2.4002.4002.4002.4002.4002.000

Item no.720542572054267205427720542972054387203924

PackPiece1111110

 

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

92

Small insulation, bandage and individual cables acc. to MLAR

  Support construction for insulations, withbracket

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the bracket on the wall, support of the installation using mounting rail.The maximum distance of the mounting rail to the wall of 200 mm fulfils the requirements of most insulation sys-tems.

 

70 217 50TypeSKA 05 VZ

Dim.Hmm

Dim. Bmm

Dim.Amm

Weightkg/100 pc.190.740

Item no.7202436

PackPiece1

 

 

 

  Support construction for insulations, with pen-dulum suspension

Suspension and fastening material, made of steel, to create the first support of pass-through installations in fireinsulation. Mounting of the pendulum with threaded rods under the ceiling. A maximum of two layers can be moun-ted with connection sleeves from two sets. The support constructions must be arranged on both sides of the wall atthe prescribed distance to the insulation system.

 

1000TypeSKP 05 VZ

Dim.Lmm

Weightkg/100 pc.235.240

Item no.7202446

PackPiece1

 

 

 

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Insu

latio

n –

mai

nten

ance

of t

he fi

re s

ectio

ns

93

Cable bandages – prevention ofthe spread of fire

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

94

Cable bandages – prevention ofthe spread of fire

Cable bandages 100

PYROLINE® Wet FSB-WB industry/exterior areas 98

PYROWRAP® Wet FSB-WLS wet rooms/interior areas 96

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

95

PYROWRAP® Wet FSB-WLSApplication in interior areas and wet roomsSystem description

 

 

The PYROWRAP® Wet FSB-WLS system can beused to wrap large cable bundles or cable supportsystems within the fire sections, in order to preventthe spread of a fire. The mesh possesses a fireprotection coating, which stops a fire in its tracks atan early stage, e.g. in the case of a short circuit. Ifthere is fire coming in from the outside, the mate-rial is not involved in the course of the fire, effec-tively preventing the spread of the fire, both in verti-cal and horizontal directions.

In the escape and rescue routes of small buildings,the mounting of a cable bandage is permitted, asonly low smoke development is to be expectedand only a small number of people must be eva-cuated. In larger buildings, the residual risk ofsmoke development is accepted, even if considera-bly more people must be evacuated. Here, the fireprotection bandage frequently presents the onlyeconomic solution compared to fire protection cei-lings or panelling with plate materials.

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

96

PYROWRAP® Wet FSB-WLSApplication in interior areas and wet roomsInstallation principle

Complete encasement of the sus-pended cable run. 

Complete encasement of thecables in a cable run as wallmounting. 

Bandage fastening with metallicrails in a single-clip installation. 

Bandage fastening with metallictightening straps in a rail installa-tion. 

Cable exit with bandaging. 

Bandaging of the cable bundleson support systems. 

Cable jacketing to prevent fire spread

Proof of application Application approval of DIBt BerlinMaterial approval of DIBt Berlin

Documents Z-56.217-3600Z-19.11-2183

Prevention of fire spread min. 90 minutes

Material properties Exterior grey glass fibre mesh, interior light greymaterials class C-s2, d0 according to EN 13501-1 – hardly flammable

Max. fastening spacing 0.5 m

Cable types and cross-sections No restriction 

Caution!Use in emergency and escape routes of building classes 4 and 5 may require the approval of the con-struction supervision, e.g. through a fire protection concept.

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

97

PYROWRAP® Wet FSB-WBApplication in industrial areas/outdoorsSystem description

 

 

The PYROWRAP® Wet FSB-WB system comprisesa fire protection bandage, which is used in areaswith special environmental conditions. The fire pro-tection bandage can be used to wrap large cablebundles or cable support systems, in order to pre-vent the spread of fire. The bandage is made of aweatherproof material, which is insensitive to

various chemicals and oils. It has constructionapproval from the DIBt as a highly flame-resistantmaterial according to DIN EN 13501-1. When thefire protection coating foams up in the event of fire,this safely prevents the spread of fire via thecables.

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

98

PYROWRAP® Wet FSB-WBApplication in industrial areas/outdoorsInstallation principle

Use of the bandage in aggressiveenvironments, e.g. offshore. 

Bandaged rising section in thetower of a wind power plant. 

Use on support systems in supplyrooms or production halls. 

Cable tunnel with bandages inpower stations. 

Bandaged cable support systemsin areas with many combustiblematerials. 

Use for photovoltaic cables runover a fire wall. 

Cable jacketing to prevent fire spread

Proof of application IEC test report of the iBMB MPA materials testing institute, BraunschweigNational and European material approval of DIBt Berlin

Document no.IEC-3630/081/10-ARZ-19.11-1971ETA-13/0158

Prevention of fire spread min. 120 minutes

Material propertiesExterior grey glass fibre mesh, interior redMaterials class EN 13501-1: B1, d0,s1 – hardly flammableWeather-resistant, resistant to various chemicals and oils

Max. fastening spacing 0.5 m

Cable types and cross-sections No restriction 

Caution!The use of photovoltaic cables over fire walls may require the approval of the local construction authori-ties. A positive special report is available.

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

99

Cable bandages

Cable bandage for dry areas  

 

 

 

10 1100TypeFSB-WLS

Lengthm

Widthmm

Weightkg/100 pc.1,000.000

Item no.7203170

PackPiece1

Fire protection jacketing made of flexible mesh with fire protection coating to prevent fire spreading viacables and cable support systems. If there is a fire, the bandage only creates very little smoke, and isthus approved by the MBO building regulations as a measure for improved behaviour in case of fire inbuilding classes 1 to 3. Hardly-flammable substance, according to EN 13501-1 - Class C-s2, d0). Exter-nal side grey, internal side light grey. Can be moist wiped, use in interiors and wet rooms. One roll con-tains 11 m², nominal thickness 0.7 mm.

 

Cable bandage for wet areas 

 

 

 

20 1100TypeFSB-WB

Lengthm

Widthmm

Weightkg/100 pc.2,200.000

Item no.7203160

PackPiece1

Waterproof fire protection jacketing made of flexible mesh with fire protection coating to prevent firespreading via cables and cable support systems. External side grey, internal side red. One roll contains22 m².

 

Complete set  

 

 

 

550 380550 880

TypeFSB-K32FSB-K82

Lengthmm

Widthmm

Weightkg/100 pc.96.000213.000

Item no.72031507203154

PackPiece11

Complete set for covering cable bundles or cable support systems without lid to prevent fire spreading.Application in outdoor areas. Each of the sets contains 4 sections of the weather-resistant cable bandageFSB-WB, 8 metal strip clips and an identification plate. Sufficient for approx. 2 m length.Dimension data: sections of the bandage FSB-WB

Scope of the surrounding cable support systems:FSB-K32 maximum 320 mmFSB-K82 maximum 820 mm(including min. 5 cm bandage overlap)

 

Always indicate the item number when ordering.

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

100

Metal strip clips

  Metal strip clips, wide

Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing. 

750 121000 121200 121500 12

TypeMBS 075MBS 100MBS 120MBS 150

Lengthmm

Widthmm

Weightkg/100 pc.2.3003.0003.6004.400

Item no.7203108720311072031127203114

PackPiece25252525

 

 

 

  Metal strip clips, narrow

Metal strip clip in ladder form with single lock. For high-temperature and weatherproof fixing. 

150 7300 7450 7610 7

TypeMBS 015MBS 030MBS 045MBS 061

Lengthmm

Widthmm

Weightkg/100 pc.0.2300.3990.6020.806

Item no.7203100720310272031047203106

PackPiece1001005050

 

 

 

Tightening straps

  Tightening strap for fastening of cable banda-ges

100 m roll of  lightweight, galvanised tightening strap, for universal fastening. 

15 100TypeFSB-SB 100

Widthmm

per rollm

Weightkg/100 pc.220.000

Item no.7203131

PackPiece1

 

 

B1

B

t1 t 

   

Tightening strap locks

  Tightening strap lock

Tightening strap lock with buckle, for simple fixing of the tightening straps FSB-SB. 

26 24TypeFSB-SV

Lengthmm

Widthmm

Weightkg/100 pc.0.340

Item no.7203132

PackPiece50

 

 

 

   

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

101

Fuse clip

Securing clip  

 

 

Stainless steel clip to secure the bend tightening strap. Provides prevention of removal from the lock. 

14 29TypeFSB-SC

Widthmm

Heightmm

Weightkg/100 pc.0.180

Item no.7203134

PackPiece50

 

Pliers

Pliers for metal strip clips  

 

 

High-quality spring chuck with cutting tool for metal strip clips, type MBS. 

TypeMBS-Z

Weightkg/100 pc.55.500

Item no.7203120

PackPiece1

 

   

Identification plates

Identification plate  

 

100

70

25

Ø 7

85

 

Universal identification plate to be written on with waterproof and light-resistant felt-tip pen for cable bandages,including two push-fit anchors.

 

GermanTypeKS-FSB DE

Language Weightkg/100 pc.2.400

Item no.7203140

PackPiece1

 

   

Always indicate the item number when ordering.

Cab

le b

anda

ges –

prev

entio

n of

the

spre

ad o

f fire

102

103

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

DirectoriesD

irect

orie

s

104

 

Directories

Numeric directory 112

Pictogram explanation 108

Test marks 106

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Dire

ctor

ies

105

D E S I G N

A S S E S S E D

American Bureau of Shipping, USA

AENOR, Producto Certificado, Spain

STOWARZYSZENIE ELEKTRYKÓWPOLSKICH, Poland

Lightning current-tested

Lightning current-tested, Class H (100 kA)

CEBEC, Belgium

Canadian Standards Association, Canada

DEMKO, Danmarks Elektriske Materielkontrol,Denmark

Deutsches Institut für Bautechnik Berlin,Germany

Det Norske Veritas

ENEC Austria

ATEX certificate for explosive areas

ELEKTROTECHNICKÝ ZKUŠEBNÌ ÚSTAV,Czech Republic

FIMKO, Finland

Forschungs- und Materialprüfungsanstalt,Germany

Russia, GOST The State Committee forStandards

Test marks for technical resources, VDE Prüf-und Zertifizierungsinstitut Offenbach,Germany

Halogen-free; without chlorine, fluorine andbromine

INMETRO, Brazil

KEMA-KEUR, Netherlands

MIndication of metric products

MAGYAR ELEKTROTECHNIKAI ELLENŐRZŐINTÉZET Budapest, Hungary

NEMKO, Norway

AFNOR Quality symbol of the Frenchstandardisation institute

Test marks

Underwriters Laboratories Inc., USA + CSA,Canada

Österreichischer Verband für Elektrotechnik,Austria

INSTITUTO ITALIANO DEL MARCHO DIQUALITÁ, Italy

RINA 1861, Ship Classification, Certificationand Services

Underwriters Laboratories Inc., USA

SEMKO An Inchcape Testing ServicesCompany, Sweden

Eidgenössisches Starkstrominspektorat,Switzerland

South African Bureau of Standards

Shock-tested, Bundesamt für Zivilschutz,Germany

Sähkötarkastuskeskus ElinspektionscentralenElectrical Inspectorate, Finland

Underwriters Laboratories Inc., USA

Underwriters Laboratories Inc., USA

Verband der Elektrotechnik, Elektronik,Informationstechnik e.V., Germany

German Association of Electricians, testedsafety

5-year warranty

Always indicate the item number when ordering.

Dire

ctor

ies

106

107

 

Surfaces

Strip galvanised

Strip galvanised/plastic-coated

Strip galvanised zinc/aluminium, double dip

Bright

Anodised

Hot-dip galvanised

Electrogalvanised

El Electrogalvanised/plastic-coated

Electrogalvanised, yellow-chromated

Electrogalvanised, yellow passivated

Electrogalvanised, transparently passivated

Primed

L Painted

Welding primed

Hot-dip galvanised

S OSOHot-dip galvanised 85 µm

Copper-plated

Nickel-plated

Galvanised, Deltatone 500

ZDM Galvanised, MAGNI 565

Zinc-aluminium coated, Galfan

Zinc scale

Conformity symbol

Communautés Européennes, EC declaration ofconformity according to EC directivesCommunautés Européennes, EC declaration ofconformity according to EC directives

RoHS-conformantRoHS-conformant

Quality marks

Halogen-free; without chlorine, fluorine and bromineHalogen-free; without chlorine, fluorine and bromine

Flame resistant 650 °CFlame resistant 650 °C

Flame resistant 750 °CFlame resistant 750 °C

Flame resistant 960 °CFlame resistant 960 °C

UV-resistantUV-resistant

Pictogram explanation 

Specific product symbols

Diameter 60 mmDiameter 60 mm

Diameter 68 mmDiameter 68 mm

Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11

Transition from LPZ 2 to LPZ 3Transition from LPZ 2 to LPZ 3

Acoustic signallingAcoustic signalling

Applications

Remote signallingRemote signalling

Acoustic signallingAcoustic signalling

Integrated Service Digital Network, ISDN applicationsIntegrated Service Digital Network, ISDN applications

Digital Subscriber Line, DSL applicationsDigital Subscriber Line, DSL applications

Analogue telecommunicationAnalogue telecommunication

Category 5 TwisterPairCategory 5 TwisterPair

Channel Performance to American EIA/TIA standardChannel Performance to American EIA/TIA standard

Measuring, controlling and regulating systemsMeasuring, controlling and regulating systems

TV applicationsTV applications

SAT-TV applicationsSAT-TV applications

MultiBase baseMultiBase base

LifeControlLifeControl

Intrinsically safe protection device for potentiallyexplosive areasIntrinsically safe protection device for potentiallyexplosive areas

Channel Performance to ISO / IEC 11801Channel Performance to ISO / IEC 11801

Power over EthernetPower over Ethernet

230/400 V system230/400 V system

Protection rating IP 54Protection rating IP 54

Protection rating IP 65Protection rating IP 65

Lightning protection classes

Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11

Combination protection device made of type 1and type 2Combination protection device made of type 1and type 2

Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11

Always indicate the item number when ordering.

Dire

ctor

ies

108

 

Lightning protection classes

Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11

Protection device to DIN EN 61643-11 or IEC 61643-11Protection device to DIN EN 61643-11 or IEC 61643-11

Lightning protection zone

Transition from LPZ 0 to LPZ 1Transition from LPZ 0 to LPZ 1

Transition from LPZ 0 to LPZ 2Transition from LPZ 0 to LPZ 2

Transition from LPZ 0 to LPZ 3Transition from LPZ 0 to LPZ 3

Transition from LPZ 1 to LPZ 2Transition from LPZ 1 to LPZ 2

Transition from LPZ 1 to LPZ 3Transition from LPZ 1 to LPZ 3

Transition from LPZ 2 to LPZ 3Transition from LPZ 2 to LPZ 3

BSS maintenance of electrical function installation

Fire-tested systemsFire-tested systems

Escape route ceiling mounting with pressure clipEscape route ceiling mounting with pressure clip

OBO Grip, wall routing typeOBO Grip, wall routing type

OBO Grip, ceiling routing typeOBO Grip, ceiling routing type

Pressure clip for maintenance of electrical function,ceiling mountingPressure clip for maintenance of electrical function,ceiling mounting

BSS anchor

Fire protection anchorFire protection anchor

Fire protection bolt tieFire protection bolt tie

BSS test marks/material class

Maintenance of electrical function class E30Maintenance of electrical function class E30

Maintenance of electrical function class E90Maintenance of electrical function class E90

Clamp clip base shapes

Clamp clip for C profile rail, slot width 11–12 mmClamp clip for C profile rail, slot width 11–12 mm

Clamp clip for C profile rail, slot width 16–17 mmClamp clip for C profile rail, slot width 16–17 mm

Clamp clip for C profile rail, slot width 18–22 mmClamp clip for C profile rail, slot width 18–22 mm

Diameter

Diameter 60 mmDiameter 60 mm

Diameter 68 mmDiameter 68 mm

Diameter 70 mmDiameter 70 mm

Diameter 74 mmDiameter 74 mm

 

Entries

4 cable entries4 cable entries

6 cable entries6 cable entries

7 cable entries7 cable entries

8 cable entries8 cable entries

9 cable entries9 cable entries

10 cable entries10 cable entries

12 cable entries12 cable entries

10 cable entries ECO10 cable entries ECO

12 cable entries ECO12 cable entries ECO

14 cable entries ECO14 cable entries ECO

16 cable entries16 cable entries

18 cable entries ECO18 cable entries ECO

24 cable entries24 cable entries

Gland thread

Thread metricThread metric

Thread PgThread Pg

Entry size

M20 entryM20 entry

M25 entryM25 entry

M32 entryM32 entry

M40 entryM40 entry

KTS side heights

Cable tray, side height 35 mmCable tray, side height 35 mm

Cable tray, side height 60 mmCable tray, side height 60 mm

Cable tray, side height 85 mmCable tray, side height 85 mm

Mesh cable tray, slant height 35 mmMesh cable tray, slant height 35 mm

Mesh cable tray, slant height 55 mmMesh cable tray, slant height 55 mm

Materials

Flat steelFlat steel

Angular steelAngular steel

U steelU steel

Round materialRound material

Pictogram explanation

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Dire

ctor

ies

109

 

Nominal cross-section

Nominal cross-section 1.5 mm²Nominal cross-section 1.5 mm²

Nominal cross-section 1.5–2.5 mm²Nominal cross-section 1.5–2.5 mm²

Nominal cross-section 2.5 mm²Nominal cross-section 2.5 mm²

Nominal cross-section 2.5–4 mm²Nominal cross-section 2.5–4 mm²

Nominal cross-section 4 mm²Nominal cross-section 4 mm²

Nominal cross-section 4–6 mm²Nominal cross-section 4–6 mm²

Nominal cross-section 6 mm²Nominal cross-section 6 mm²

Nominal cross-section 10 mm²Nominal cross-section 10 mm²

Nominal cross-section 16 mm²Nominal cross-section 16 mm²

Nominal voltage

Nominal voltage 400 VNominal voltage 400 V

Nominal voltage 500 VNominal voltage 500 V

Nominal voltage 660 VNominal voltage 660 V

Polarity

3-pole3-pole

5-pole5-pole

7-pole7-pole

8-pole8-pole

10-pole10-pole

12-pole12-pole

Slot widths

Slot width 7.5 mmSlot width 7.5 mm

Slot width 11 mmSlot width 11 mm

Slot width 11–12 mmSlot width 11–12 mm

Slot width 12 mmSlot width 12 mm

Slot width 15 mmSlot width 15 mm

Slot width 16 mmSlot width 16 mm

Slot width 16.5 mmSlot width 16.5 mm

Slot width 16–17 mmSlot width 16–17 mm

Slot width 17 mmSlot width 17 mm

Slot width 18 mmSlot width 18 mm

Slot width 22 mmSlot width 22 mm

Slot width 35 mmSlot width 35 mm

Pictogram explanation 

Screw heads

Philips screwPhilips screw

Torx screwTorx screw

Phillips screwPhillips screw

PozidrivePozidrive

Firing devices

Bolt-firing toolBolt-firing tool

Nail deviceNail device

Protection rating

Protection rating IP 20Protection rating IP 20

Protection rating IP 30Protection rating IP 30

Protection rating IP 31Protection rating IP 31

Protection rating IP 44Protection rating IP 44

Protection rating IP 54Protection rating IP 54

Protection rating IP 55Protection rating IP 55

Protection rating IP 65Protection rating IP 65

Protection rating IP 66Protection rating IP 66

Protection rating IP 67Protection rating IP 67

Protection rating IP 68Protection rating IP 68

Metals

Aluminium

Aluminium/steel

Stainless steel, rustproof

Stainless steel, rustproof

Stainless steel, rustproof

Copper

Brass

Steel

Malleable iron

Die-cast zinc

Plastics

Acrylonitrile butadiene styrene

Duroplast, Aminoplast, type 131.5

Duroplast, melamine resin, type 150

Ethylene vinyl acetate

Always indicate the item number when ordering.

Dire

ctor

ies

110

 

Plastics

Fibre-proof material DIN 28091

Fibre-glass-reinforced plastic

Rubber mixture

Nitrile rubber

Petrolatum

Polyamide

Polyamide, fibre-glass reinforced

Polybutylene terephthalate

Polycarbonate

Polyethylene

Polypropylene

Polypropylene, fibre-glass reinforced

Polystyrene

Polyvinylchloride

Cellular polyethylene

Schu

tzin

stal

latio

n Ab

scho

ttung

en u

nd K

abel

band

agen

/ en

/ 20

21/0

6/22

09:

35:2

9 09

:35:

29 (L

LExp

ort_

0292

8) /

2021

/06/

22 0

9:35

:54

Always indicate the item number when ordering.

Dire

ctor

ies

111

Numeric directory

 /100 pc.

3141047 1752532113141128 175253334

3400069 1852980903400085 185298151

3402207 1853003113402215 185300373

3498108 1865596573498261 1865596643498262 186842568/100 pc.

3498320 7864118183498396 786411948

/pc.7202200 1758565597202201 1758565667202203 1758565977202204 1758566037202205 1758566107202206 1758566277202207 1758566657202208 1758566727202209 1758566897202210 1758567197202212 7660869177202213 7760869247202214 7660536747202215 7760869317202216 7760869487202217 7760869797202218 7760869867202219 7760869937202220 7760870067202283 1958478547202295 2658501207202300 1658501377202302 1758501447202305 1964471387202306 1959189297202308 1864231257202309 1964471527202310 2658501827202312 2658501997202322 6654281907202436 2068395207202446 206839551

/pc.7202505 4264344597202510 4254282757202515 6464344667202521 4358479157202553 6564345037202557 6564345107202561 6564345277202565 6564345657202569 6564345727202573 6564345897202577 6564346267202581 6564346337202613 6554283367202617 6554283437202624 6561428117202628 6561429347202660 6561440137202709 3464609917202725 3464608787202741 3464607557202904 1958478617202912 1958478787202963 3458478857202971 345847892

/100 pc.7203100 10156933457203102 10156933527203104 8556933697203106 10156933767203108 10156933837203110 10156933907203112 1015693406

Item no. PageGTIN  /100 pc.

7203114 1015693413/pc.

7203120 10256934207203131 1015993056/100 pc.

7203132 10156934447203134 1025726425

/pc.7203140 10258116717203150 10059218517203154 10059218687203160 10057064347203163 1966087377203170 10064755137203800 405817499price/pac7203803 415817505

/pc.7203806 4158175367203809 4158175437203813 4166428927203816 416820900

/pc.7203818 4264363547203900 4066195047203903 6466195117203906 6666195287203909 6566195357203912 6566195427203915 6566195597203919 6566195667203921 6566195737203924 206619580

7204290 8468101617204292 8468101787204296 846810185

/pc.7204300 2061357527204304 2061357697204306 846448081

7205425 2054482597205426 2064619747205427 2057038087205429 2057256957205438 206446872

7206058 1658500837206104 165850076

Item no. PageGTIN

Always indicate the item number when ordering.

Dire

ctor

ies

112

113

OBO Bettermann Holding GmbH Co. KGP.O. Box 112058694 Menden, Germany

Customer ServiceTel.:+49 23 73 89 - 17 00Fax: +49 23 73 89 - 12 [email protected]

www.obo-bettermann.com

Building Connections

 

© O

BO

BETT

ER

MA

NN

Ord

er n

o. 9

196339 0

6/2

021 E

N