S700 S710 E 1217513, Product data sheet - SICK · 2021. 1. 7. · S710 E 1217513 1217513 The...

10
Product data sheet S710 E 1217513 S700 EXTRACTIVE GAS ANALYZERS

Transcript of S700 S710 E 1217513, Product data sheet - SICK · 2021. 1. 7. · S710 E 1217513 1217513 The...

  • Pro

    du

    ct

    da

    ta s

    he

    et

    S710 E 1217513S700

    EXTRACTIVE GAS ANALYZERS

  • ABCDEF

    HIJKLMNOPQRST

    S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    Ordering information

    Type Part no.

    S710 E 1217513 1217513

    The product has been discontinued. Please contact your SICK sales representative for more information about a replacementproduct.

    Other models and accessories www.sick.com/S700

    Detailed technical data

    Technical specificationsDescription 19″ rack enclosure with 3 rack units, for integration in cabinets

    Measured values CO, NO, O2, SO2

    Maximum number of measurands 4

    Measurement principles NDIR spectroscopy, electrochemical cell

    Gas flow rate

    5 l/h ... 100 l/h

    Required operating range: 30 l/h ... 60 l/h

    Measuring ranges

    CO 0 ... 1,200 mg/m³ / 0 ... 6,000 mg/m³

    NO 0 ... 1,000 mg/m³ / 0 ... 8,000 mg/m³

    O2 0 ... 10 Vol.-% / 0 ... 25 Vol.-%

    SO2 0 ... 1,000 mg/m³ / 0 ... 7,000 mg/m³

    Response time (t90) MULTOR analyzer module: ≤ 25 sAt 60 l/h, depending on cuvette length, gas flow and number of measuring componentsOXOR-E analyzer module: 20 sTypical at 60 l/h, depending on gas flow

    Sensitivity drift

    MULTOR analyzer module ≤ 1 %: of measuring range full scale per week

    OXOR-E analyzer module ≤ 1 %: of measuring range full scale per week

    Zero point drift

    MULTOR analyzer module ≤ 1 %: of smallest measuring range per week

    OXOR-E analyzer module ≤ 2 %: of smallest measuring range per month

    Sample gas temperature

    Analyzer inlet: 0 °C ... +45 °C

    Process pressure

    Hosed gas lines: –200 hPa ... 300 hPa

    Process gas humidity

    Non-condensing

    Dust load

    Free of dust and aerosols

    2 GAS ANALYZERS | SICK Product data sheet | 2021-03-31 22:04:45

    Subject to change without notice

    http://www.sick.com/1217513http://www.sick.com/1217513https://www.sick.com/S700

  • S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    Ambient temperature

    +5 °C ... +45 °C

    Storage temperature

    –20 °C ... +70 °C

    Ambient pressure

    700 hPa ... 1,200 hPa

    Geographical altitude ≤ 2,000 m (above mean sea level)

    Ambient humidity

    ≤ 95 %Relative humidity; non-condensing

    Electrical safety CE

    Enclosure rating

    IP20

    Analog outputs 4 outputs:0/4 ... 20 mA, + 500 Ω

    Digital outputs 8 relay contacts:Three relay outputs preset for failure, service and maintenance8 Open collector outputs:Freely adjustable

    Digital inputs 8 optical coupler inputs:Electrically isolated; freely programmable

    Modbus ✔

    Type of fieldbus integration RTU RS-232

    Indication

    LC display

    Operation Menu-driven operation via LC-display and membrane keyboard

    Menu languages German, English, French, Italian, Dutch, Polish, Swedish, Spanish

    Dimensions (W x H x D)

    483 mm x 132.5 mm x 390 mm (for details see dimensional drawings)

    Weight

    10 kg ... 20 kgDepending on configuration

    Material in contact with media Viton B, PVDF, Calciumfluorid, gold, Aluminum

    Power supply

    Voltage 100 V AC / 115 V AC / 230 V AC

    Frequency 48 ... 62 Hz

    Power consumption ≤ 150 WDepending on system configuration

    Sample gas connections

    PVDF bulkhead fitting

    Corrective functions Automatic testing and adjustment with test gasesManual adjustment with test gases

    Integrated components MULTOR analyzer moduleOXOR-E analyzer modulePVDF bulkhead fitting

    2021-03-31 22:04:45 | Product data sheet

    Subject to change without notice

    GAS ANALYZERS | SICK 3

  • ABCDEF

    HIJKLMNOPQRST

    S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    ClassificationsECl@ss 5.0 27150302

    ECl@ss 5.1.4 27150302

    ECl@ss 6.0 27150302

    ECl@ss 6.2 27150302

    ECl@ss 7.0 27150302

    ECl@ss 8.0 27150302

    ECl@ss 8.1 27150302

    ECl@ss 9.0 27150302

    ECl@ss 10.0 27150302

    ECl@ss 11.0 27150302

    ETIM 5.0 EC001190

    ETIM 6.0 EC001190

    ETIM 7.0 EC001190

    UNSPSC 16.0901 41115406

    Dimensional drawing (Dimensions in mm (inch))S710 design

    7 8 9

    4 5 6

    1 2 3

    0

    Esc

    Help

    Enter

    Function

    Service

    Alarm

    483 (19.00)

    13

    2.5

    (5.2

    2)

    42

    (1

    .65

    )

    39

    0 (

    15

    .35

    )

    37

    5 (

    14

    .76

    )

    35

    0 (

    13

    .78

    )

    11

    2 (

    4.4

    1)

    82

    (3

    .23

    )

    52

    (2

    .05

    )

    22

    (0

    .87

    )

    11

    5

    (4.5

    3)

    0

    1 2 3 4

    ①  1. sample gas inlet②  Exhaust gas outlet③  2. sample gas inlet④  3. sample gas inlet

    4 GAS ANALYZERS | SICK Product data sheet | 2021-03-31 22:04:45

    Subject to change without notice

  • S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    S710 and S711 design

    7 8 9

    4 5 6

    1 2 3

    0

    Esc

    Help

    Enter

    Function

    Service

    Alarm

    S711S710

    483 (19.00)

    13

    2.5

    (5.2

    2)

    42

    (1

    .65

    )

    39

    0 (

    15

    .35

    )

    37

    5 (

    14

    .76

    )

    35

    0 (

    13

    .78

    )

    29

    0 (

    11

    .42

    )

    27

    5 (

    10

    .83

    )

    25

    0 (

    9.8

    4)

    11

    2 (

    4.4

    1)

    82

    (3

    .23

    )

    52

    (2

    .05

    )

    22

    (0

    .87

    )

    11

    5

    (4.5

    3)

    0

    1 2 3 4

    ①  1. sample gas inlet②  Exhaust gas outlet③  2. sample gas inlet④  3. sample gas inlet

    2021-03-31 22:04:45 | Product data sheet

    Subject to change without notice

    GAS ANALYZERS | SICK 5

  • ABCDEF

    HIJKLMNOPQRST

    S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    S715 design

    7 8 9

    4 5 6

    1 2 3

    0

    Esc

    Help

    Enter

    Function

    Service

    Alarm

    28

    0 (

    11

    .02

    )

    42

    (1.6

    5)

    10

    .5

    (.4

    1)260 (10.24)

    290 (11.42)

    320 (12.60)

    350 (13.78)

    554 (21.81)

    530 (20.87)

    500 (19.69)

    442 (17.40)20 (0.79)

    028 (1.10)

    60 (2.36)

    92 (3.62)

    124 (4.88)

    0

    35 (1.38)

    70 (2.76)

    205 (8.07)

    270 (10.63)

    385 (15.16)

    45 (1.77)

    46

    9 (

    18

    .46

    )

    42

    5 (

    16

    .73

    )

    41

    5 (

    16

    .34

    )

    35

    7 (

    14

    .06

    )

    1234

    57

    6

    8

    9

    5

    6

    ①  1. sample gas inlet②  Exhaust gas outlet③  2. sample gas inlet④  3. sample gas inlet⑤  Purge gas inlet⑥  Purge gas outlet

    6 GAS ANALYZERS | SICK Product data sheet | 2021-03-31 22:04:45

    Subject to change without notice

  • S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    S720 Ex design

    180 (7.09)

    140 (5.51)

    16

    8 (

    6.6

    1)

    19

    8 (

    7.8

    0)

    27

    6 (

    10

    .87

    )

    30

    0 (

    11

    .81

    )3

    0 (

    1.1

    8)

    73

    (2.87)178

    (7.01)

    Ø 360 (14.17)

    430 (16.93)

    480 (18.90)

    27

    0 (

    10

    .63

    )

    0 58

    (2

    .28

    )

    14

    8 (

    5.8

    3)

    19

    8 (

    7.8

    0)

    030 (1.18)40 (1.57)

    90 (3.54)

    18 x 24

    (.71 x .94)

    1 2

    3 4

    5

    6

    7

    8

    ①  1. sample gas inlet②  Exhaust gas outlet③  2. sample gas inlet④  3. sample gas inlet⑤  Purge gas inlet⑥  Purge gas outlet

    2021-03-31 22:04:45 | Product data sheet

    Subject to change without notice

    GAS ANALYZERS | SICK 7

  • ABCDEF

    HIJKLMNOPQRST

    S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    S721 Ex design

    260 (10.24)

    220 (8.66)

    30

    0 (

    11

    .81

    )

    18

    5 (

    7.2

    8)

    21

    5 (

    8.4

    6)

    40

    0 (

    15

    .75

    )3

    0 (

    1.1

    8)

    95

    (3.74)

    Ø 480 (18.90)

    546 (21.50)

    596 (23.46)

    18 x 24

    (.71 x .94)

    39

    6 (

    15

    .59

    )

    0 80

    (3

    .15

    )

    17

    0 (

    6.6

    9)

    22

    0 (

    8.6

    6)

    0

    40 (1.57)30 (1.18)

    90 (3.54)

    210

    (8.27)

    1 2

    3 4

    5

    6

    7

    8

    ①  1. sample gas inlet②  Exhaust gas outlet③  2. sample gas inlet④  3. sample gas inlet⑤  Purge gas inlet⑥  Purge gas outlet

    8 GAS ANALYZERS | SICK Product data sheet | 2021-03-31 22:04:45

    Subject to change without notice

  • S710 E 1217513 | S700EXTRACTIVE GAS ANALYZERS

    Display and keyboard for S720 Ex and S721 Ex design

    7 8 9

    4 5 6

    1 2 3

    0

    Esc

    Help

    Enter

    192 (7.56)

    305 (12.01)

    265 (10.43)

    23

    3 (

    9.1

    7)

    19

    7 (

    7.7

    6)

    Ø 13 (.51)

    10 (.39)

    12

    0

    (4.7

    2)

    110

    (4.33)

    L ≤ 2 m (6.56 ft)

    2021-03-31 22:04:45 | Product data sheet

    Subject to change without notice

    GAS ANALYZERS | SICK 9

  • Onlin

    e da

    ta s

    heet

    SICK AG | Waldkirch | Germany | www.sick.com

    SICK At A GlAnCeSICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment.

    We have extensive experience in a wide range of industries and understand their processes and require-ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.

    Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma-chine life cycle and ensure safety and productivity.

    For us, that is “Sensor Intelligence.”

    WOrldWIde preSenCe:Contacts and other locations – www.sick.com