S7-200
-
Upload
van-thang-nguyen -
Category
Documents
-
view
78 -
download
0
Transcript of S7-200
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 1© Siemens AG 2004 - Subject to change without prior notice
www.siemens.com/s7-200/
SIMATIC S7-200
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 2© Siemens AG 2004 - Subject to change without prior notice
Positioning within the SIMATIC family
Small,compact systems
Easiest programming tools with Wizards
micro automation sets as solution from one supplier
Shared data management, configuring and communications
Highest performance
Programming with high-level languages
Micro Automation
S7-200
LOGO!
Totally IntegratedAutomation
S7-300
S7-400
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 3© Siemens AG 2004 - Subject to change without prior notice
S7-200 Second Generation Overview
CPU 221(10 I/O Points)
CPU 222(14 I/O Points)
CPU 226(40 I/O Points)
) CPU 224(24 I/O Points)
CPU 224XP(24 I/O Points)
Improved2004
New2004
Improved2004
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 4© Siemens AG 2004 - Subject to change without prior notice
Features:Integrated Inputs/OutputsMax. Expansion ModulesMax. # of Dig. I/O ChannelsAnalogue Points In/Out/MaxProgram/Data MemoryBoolean Execution TimeBit Relays/Counters/TimersHigh Speed CountersReal Time ClockPulse OutputsCommunication InterfaceAnalogue Potentiometers
CPU 2216DI/4DO
-10-
4KB/2KB0.37 µs
256/256/2564 x 30 kHzoptional
2 x 20 kHz1x RS-485
1
CPU 2228DI/6DO
278
8/4/104KB/2KB0.37 µs
256/256/2564 x 30 kHzoptional
2 x 20 kHz1x RS-485
1
Features: CPUs (1/2)RETURN
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 5© Siemens AG 2004 - Subject to change without prior notice
Features: CPUs (2/2)
CPU 22414 DI/10 DO
-7
16828/14/358/12 KB
8 KB0.22 µs
256/256/2566 x 30 kHz
Integrated2 x 20 kHz1 x RS-485
2
CPU 224XP14 DI/10 DO
2AI/1A07
16830/15/3812/16 KB
10 KB0.22 µs
256/256/2564 x 30 kHz2 x 200 kHzIntegrated
2 x 100 kHz2 x RS-485
2
CPU 22624 DI/16 DO
-7
24828/14/3516/24 KB
10 KB0.22 µs
256/256/2566 x 30 kHz
Integrated2 x 20 kHz2 x RS-485
2
Features:Integrated Inputs/OutputsIntegrated Analogue In/OutMax. Expansion ModulesMax. # of Dig. I/O ChannelsAnalogue Points In/Out/MaxProgram/Data MemoryBoolean Execution TimeBit Relays/Counters/TimersHigh Speed Counters
Real Time ClockPulse OutputsCommunication InterfaceAnalogue Potentiometers
RETURN
New & Improved2004
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 6© Siemens AG 2004 - Subject to change without prior notice
Standards Compliance:
European Underwriters Factory C-TickCommunity Laboratory Mutual for Australia &
Canada & Approved New Zealand United States
Maritime Approvals:
S7-200 Standards
Lloyds Register of Shipping (LRS)
American Bureauof Shipping (ABS)
GermanLloyd (GL)
Det NorskeVeritas (DNV)
Nippon KaijiKyokai (NK)
BureauVeritas (BV)
Polski RejestrStatkow
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 7© Siemens AG 2004 - Subject to change without prior notice
Built-in Features
Removable Terminal Blocks
(224(XP),226)
Communication Port(s)
24V Sensor Power Output
Mounting Holes for Panel Installation
Snap-On Clipfor DIN Rail Mounting
Cartridge Slot
CPU Status LEDs
Internal:- Power Supply- Super Capacitor- Clock (224(XP),226)
I/O Point Status LEDs
Improved2004
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 8© Siemens AG 2004 - Subject to change without prior notice
224XP Built-in Features
Removable Terminal Blocks (224,226)
Communication Ports
24V Sensor Power Output
Mounting Holes for
Panel Installation
Snap-On Clipfor DIN Rail Mounting
Cartridge Slot
Internal:- Power Supply- Super Capacitor- Clock (for 224,224XP,226)
I/O Point Status LEDs
Removable Analogue Terminals
New2004
CPU Status LEDs
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 9© Siemens AG 2004 - Subject to change without prior notice
SIMATIC S7-200 in detail ...
Flexible Memory Modules
Battery module
Clock and battery module
Real-time clock and calendar (for 221, 222 CPU)
Typically 200 days backup.
Backup of the internal data (data block)
Typically 200 days backup
For general program transfer and backup
Data Logging Files, Recipes Files, and General File Storage
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
New2004
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 10© Siemens AG 2004 - Subject to change without prior notice
Diagnostic LED on … on New & Improved CPUs
All the new and improved CPUs have a multi purpose Diagnostic LED.
The Diagnostic LED is combined with the System Fault LED.The combined LED is either RED or YELLOW depending on the fault.The Diagnostic LED is controlled by both the operating system and the user’s program by means of the Diagnostic instructionThe Diagnostic LED can be turned on when a value is FORCED or anI/O Error occurs or the USER’s program commands it on.
New Micro/Win InstructionDiagnostic LED
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
New2004
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 11© Siemens AG 2004 - Subject to change without prior notice
Expansion I/O Modules: General
Up to 2 Modules (EM) for 222 CPUs….up to 7 EMs for 224/226 CPUs
Removable Terminals on digital I/O ModulesModule Connection via I/O Expansion Ribbon Cable
CPU-Basic Device + Expansion Module
ConnectorConnection slot
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 12© Siemens AG 2004 - Subject to change without prior notice
Expansion I/O Modules …many options
Digital
Analogue
Tech
nolo
gy
8 In DC
8 In AC, 120/230 VAC
16 In DC
8 In / 8 Out DC-DC
8 Out DC - 0.75 A
4 Out DC – 5A
4 Out Relay - 10 A
8 Out Relay - 2 A
8 In / 8 Out DC-Relay
16 In / 16 Out DC-DC
4 In / 4 Out DC-Relay
4 In / 4 Out DC-DC
8 Out AC -120/230 VAC, 0.5 A
16 In / 16 Out DC-Relay
Tem
pera
tur e
Mea
s ure
me n
ts
Position2 In RTD
4 In T/C
4 In
4 In / 1 Out
2 Out IT Communication
AS-i Master
Ethernet
PROFIBUS DP Slave
Modem
Com
mun
ikat
ion
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 13© Siemens AG 2004 - Subject to change without prior notice
Positioning module (EM 253)
Provides High-Speed control, …from 12 to 200,000 PPS.Configurable backlash compensationContinuous operation
Supports:Jerk (S curve) or Linear acceleration and decelerationSupports absolute, relative and manual methods of position control
Simple programming and commissioning with the Wizard
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 14© Siemens AG 2004 - Subject to change without prior notice
Phone Network
+ HTML
+ FTP
S7-200 Networking possibilities: Overview
S7-22x CP243-2
EM 277
CP243-1
EM 241
CP243-1 IT
Ethernet Network
PROFIBUS Network
AS Interface Field Bus
PPI/MPI Network
ASCII Protocol (FreePort)
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 15© Siemens AG 2004 - Subject to change without prior notice
Modem module (EM 241)
Provides:International telephone line interfaceModem programmed with STEP7 Micro/WIN Password protectionSecurity callbackPlug&Play
Supports:The Modbus RTU protocolNumeric and text pagingSMS messaging (depending on provider)CPU-to-CPU or CPU-to-Modbus data transfers
Simple programming with the Micro/WIN Wizard
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 16© Siemens AG 2004 - Subject to change without prior notice
PROFIBUS DP Slave Module (EM 277)
Connects the S7-200 as a slave to a PROFIBUS DP network
Provides:9.6 KBit/s to 12 Mbit/s Transfer Rate (with Auto Detection) PPI-Advanced, MPI und PROFIBUS DP protocolFour LED Status IndicatorsStation Address Selectable by Rotary Switches (0..99)
Supports:Max. 99 Devices on the Bus (Addresses from 0 ... 99)Up to 1200 m Segment Length (at max. 93.75 KBit/s)
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 17© Siemens AG 2004 - Subject to change without prior notice
AS Interface Master Module (CP 243-2)
Provides:2 Pushbuttons on Module to ToggleDisplay & Operation ModeLEDs to Display Slave Status, Errors and Bus Status
Supports:62 AS-Interface Slaves can be ConnectedCycle Length 5 ms (31 slaves) or 10 ms (62 slaves) Cable Length 100 mClass M1e Master
Two Operation Modes:Standard Operation(accessing I/O Data Blocks of the Slaves)Extended Operation(also Write Parameter Data or Poll Diagnostic Data)
Simple Programming with the Wizard
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 18© Siemens AG 2004 - Subject to change without prior notice
Ethernet Module (CP 243-1)
Simple…Connections as an EMAllows processing dataSimple Network administrationEasy Exchanging of Modules (plug & play)
ProvidesEthernet access via an RJ45 jackA connection to PC-Access softwareRemote programming, configuration and diagnosticsSimultaneous communication with up to 8 S7 controllers
Facilitates a flexible and distributedautomation structure
Simple Programming with the Wizard
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 19© Siemens AG 2004 - Subject to change without prior notice
Ethernet Networking with CP 243-1
Communication via Industrial EthernetUses Standard Read & Write ServicesUp to 212 bytes of user data per command.Supports up to 8 communication channelsClient / Server operatingSimple Programming with the Wizard
EthernetCable
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 20© Siemens AG 2004 - Subject to change without prior notice
IT Communications Module (CP 243-1 IT)
Provides:The same network features like the CP 243-1Send up to 32 E-Mail’sTransfers up to 32 files via FTPIntegrated Web ServerBuilt-in user diagnostic HTML pagesBuilt-in system diagnostic HTML pages
Supports:Visualization with JAVA and HTMLData exchange of files by means of FTP
Simple Programming with the Wizard
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 21© Siemens AG 2004 - Subject to change without prior notice
Human-Machine Interface Units
Matched to the S7-200
TouchPanels:- TP 070- TP 170microText
DisplayTD 200
Textpanels
Graphicspanels PC-based
humanmachineinterface
Optimal Price / Performance ratioEasy Engineering with TD 200-Wizard, TP Designer and WINCC flexible micro
Text DisplayTD 200CWith User-CustomizedFaceplate
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 22© Siemens AG 2004 - Subject to change without prior notice
STEP7-Micro/WIN 32
Simple Installation and Configuration
EASY to Learn, EASY to Use
Comprehensive programming tool
Find & Correct quickly fixes errors
Tools to handle Running PLC Changes
Documentation for easy maintenance
Wizards simplify programming tasks
Software tools for easy commissioning
…. Setting THE Standard in Micro PLC Programming
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 23© Siemens AG 2004 - Subject to change without prior notice
Your Choice of Editors
Use the right tool for the jobLadder & FBD editors for graphiclanguages (IEC 1131-3)STL for text programmingSwitch between editors as necessaryEasy error identificationSave project in any case
STL FBD
LADDER
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 24© Siemens AG 2004 - Subject to change without prior notice
The Wizards: Overview
(a) High Speed Counters(b) NETR/NETW Networking(c) PID Control Instruction
(b) Position Module(a) PTO/PWM
TD 200 Text Display
(a) Modem Module
(b) External Modem
Ethernet Module
Internet Module
(a) Map AS-i Slaves
Position Control Panel
Wizards make the programming easier
RecipeWizard
Data Log Wizard
PID Auto Tune Control Panel
(b) Change AS-I Addresses
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 25© Siemens AG 2004 - Subject to change without prior notice
Application examples
Conveyor systems
Filling plants
Woodworking
Pump controls
Vacuum suction systems/elevators
...over 1,000,000 applications world wide
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 26© Siemens AG 2004 - Subject to change without prior notice
Easy to adjust to individual customer requestsRemote monitoring for cost-effective service
Digital monitoring of shaft using incremental encoders (exact position acquisition of the elevator)
Saves on magnetic switches
Elevators with optimal stopping accuracy
Cost savings
Quality enhancement
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 27© Siemens AG 2004 - Subject to change without prior notice
Suction extraction systems for woodworking
Reduction in wiring and startup costs using the AS-Interface Connection of shutoff valves in the suction systemEfficient service using modem technology
Calculation of the optimal suction power
Reduction in power consumption
Cost savings
Quality enhancement
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 28© Siemens AG 2004 - Subject to change without prior notice
Woodworking machinery
Flexible solution for easy expansionEasy implementation of customer requirements
Precise positioning for better control
Cost savings
Quality enhancement
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 29© Siemens AG 2004 - Subject to change without prior notice
Low-cost ball presses
Simple and fast changeover from relay technology to PLC electronicsLow space requirements for smaller control cabinet
Flexible solution for easy expansionIncreased operational information using non-volatile data backup
Quality enhancement
Cost savings
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 30© Siemens AG 2004 - Subject to change without prior notice
Maintenance and Support
Worldwide Support:Global Service and Repair NetworkQuick Spare Parts Delivery24/7 Support HotlineProgramming SupportProduct and Application InformationTraining Seminars
Internet Software Support:Extensive Product Information including ManualsSoftware and Documentation UpdatesTips & Tricks Application ExamplesDemo SoftwareOnline Training (Step 2000)
Overview
Approvals
Hardware CPU
Hardware EM
Communication EM‘s
HMI
MicroWin V4.0
Applications
Positioning
Automation and Drives
SIMATIC HMIThe Human Machine Interface
SIMATIC S7-200
for internal use only Automation and Drives
SIMATIC S7-200
A&D AS, 07/2004, Chart 31© Siemens AG 2004 - Subject to change without prior notice
SIS Co., Ltd.Đại lý phân phối thiết bị SIEMENS Tự động hóa53 Lê Thị Hồng Gấm, Quận 1, TP Hồ Chí MinhTel: 84-8-914 3632 / 914 3633Fax: 84-8-821 7184Email: [email protected]; [email protected]: sis-vn.com