Rumex International Co.rumex.com/download/IOLs_AquaFree_Hydrosense.pdf · 2014. 12. 26. · Rumex...

27
Rumex International Co. Rumex International LTD. IOLs Head office: RUMEX INTERNATIONAL COMPANY 13770 58th Street North, Suite 317 Clearwater, FL 33760, USA Manufactured: RUMEX INTERNATIONAL Limited 311 Shoreham street Sheefield, South Yorkshire, S2 4fa UK

Transcript of Rumex International Co.rumex.com/download/IOLs_AquaFree_Hydrosense.pdf · 2014. 12. 26. · Rumex...

PowerPointIOLs
Head office: RUMEX INTERNATIONAL COMPANY 13770 58th Street North, Suite 317
Clearwater, FL 33760, USA
South Yorkshire, S2 4fa UK
2 www.rumex.net
• Extreme double-square edge around entire
optic periphery
• Bi-Sign Aspheric
4 www.rumex.net
• Exceptional clarity – no glistenings
• Water content: 0.30%
• Not tacky – Lens does not stick to itself or instruments
5 www.rumex.net
6.0 13.0
Material Acrylmex Hydrophobic Acrylic.Clear
Acrylmex Hydrophobic Acrylic.Yellow chromophore
No glistenings. UV-filter and the filter of blue light.
Design of the optical edge Double square-edge Double square-edge 360° barrier helps to prevent PCO – causing cellular migration
Refractive Index 1.49 (same as PMMA) 1.49 (same as PMMA) Dysphotopsia phenomena are significantly reduced or non-existing
Angulation 5° 5° Eliminates wrinkles&reduces PCO
Diopter range (0.5 increments)
4.0 – 34.0D 4.0 – 34.0D
Foldable lens –Single piece – Hydrophobic
A-Constant: 117.8
periphery
The lenses are suitable for MICS procedure
Material Acrylmex Hydrophilic Acrylic.Clear Proven efficacy and safety
Design of the optical edge Double square-edge 360° barrier helps to prevent PCO – causing cellular migration
Angulation 5° Eliminates wrinkles&reduces PCO
Diopter range (0.5 increments) 4.0 – 34.0D Encompasses the entire range of refraction
Foldable lens –Single piece – Hydrophilic
A-Constant: 118.2
8 www.rumex.net
Bi-Sign Aspheric
flatter region within about 3 mm diameter and a steeper
region at the lens periphery as compared with spherical
surface of the same power
• Bi-Sign Aspheric produces aberrations of opposite signs
over the lens surface to balance out the aberrations within
the lens inself for large pupils
• Bi-Sign Aspheric maintance high image quality for full range
of corneal shapes from Q=0 (spherical cornea) to Q=-0.53
(fully aspheric cornea)
Spherical IOL of the power even with lens misalignment
• Bi-Sign aspheric is designed for predictable image contrast
9 www.rumex.net
Double square-edge
minimize capsular bag stretching, but to conform
the optic edge for maximum capsular adhesion.
10 www.rumex.net
Square-Edge Design
•Acrylmex material
•Extreme double-square edge around entire optic periphery
•Bi-Sign Aspheric
11 www.rumex.net
Double square-edge design encompasses entire optic periphery, forming a 360° barrier to help prevent PCO-
causing cellular migration.
PROPERTIES
At least 90% above 410 nm, less than 10% below 375 nm
20.0D AquaFree Lens
13 www.rumex.net
TRANSMISSION PROPERTIES
At least 85% above 510 nm, less than 10% below 395 nm
20.0D AquaFree Yellow Lens
14 www.rumex.net
TRANSMISSION COMPARISON GRAPH
Competitor #1
Competitor #2
– All 20.0D
– AquaFree has 5° haptic angle; AcrySof® and Tecnis® have 0°
Parameters Tested
– Decentration analysis
Mechanical Comparison
16 www.rumex.net
AquFree® Tecnis® AcrySof®
Clear optic (mm) 5.0 6.0 6.0
17 www.rumex.net
- Excellent centration
18 www.rumex.net
AquaFree
(Rumex)
Refractive Index 1.49 1.55 1.47
Ø overall 13.0 13.0 13.0
Ø optic 6.0 6.0 6.0
A-Constant 117.8 118.7 118.8
Aspheric posterior posterior anterior
Angulation 5° 0° 0°
#1 #2 #3
Hydro-Sense (Rumex)
Ø overall 12.5 13.0 12.5
Ø optic 6.0 6.0 6.0
A-Constant 118.2 118.6 118
Aspheric posterior posterior posterior
Angulation 5° 5° 0°
• Improved image quality and contrast sensitivity, specifically in low light conditions
• Lower refractive index of hydrophobic material (1.49)
• Designed to eliminate capsular bag stretching
• Bi-sign Aspheric
• Double square-edge
21 www.rumex.net
AquaFree Preloaded Yellow&Clear
Rumex IOLs are preloaded in an Accuject® injection system, suitable for incisions as small as 2.0 mm.
Preloaded system represents exceptional reliability for safe and effective lens injection. The compact design
and integrated cartridge of the fully single-use Accuject ® system enables simple, predictable IOL injection.
23 www.rumex.net
24 www.rumex.net
25 www.rumex.net
Benefits of Heparin Surface Modification
Rumex Hydrophobic IOLs with Heparin are preloaded in an Accuject™ injection system, suitable for a 2,0 or 2,2
mm incision
•Results in reduced foreign-body reactions
•Appears to be a valuable tool to decrease implant-associated bacterial endophthalmitis
•Anti-Adhesion effect of Haptics and Optics during implantation
•Reduces postoperative inflammotary responses in the early postoperative
26 www.rumex.net
Parameters AquaFree AcrySert C Nex-LOAD Isert Preloaded
Ø overall 13 mm 13 mm 12.5 mm 12.5 mm
Ø optic 6 mm 6 mm 6 mm 6 mm
Refractive Index 1.49 1.55 1.52 -
A-Constant 118,5 118.7 119.2 118.4
Aspheric Posterior (-0.14) Posterior (-0.2) Posterior Posterior (-0.18)
Angulation 5 0 7 0
Water content 0.3% 0.3% - -
+16,5 to 26,0D (0,5D increments)
+10.0 to +27 (0,5D increments)
+27,0 to +28,0
Min.incision 2,0 mm (WA) 2.6 mm 2.8 mm 2.2 mm
Heparin + - - -
RUMEX INTERNATIONAL COMPANY 13770 58th Street North, Suite 317
Clearwater, FL 33760, USA Tel: +1 (727) 568 0909
Toll Free: +1 (877) 77 RUMEX Fax: +1 (727) 568 0919
Email: [email protected] Webstore: www.rumex.net
South Yorkshire, S2 4fa UK Tel: +371 6616 3182
Thank you!