RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction...

8
C-3 RTD Selection Guide Series No. Probe Type Termination Style Element Features Typical Applications Options Available PRS-S-M12 PRS-H-M12 Sanitary M12 Connector Pt100, Class A 3-A Approved, Clean-In-Place Mounting Flange, Standard & Heavy Duty Probes Food, Dairy & BioPharm Processes Cables, Transmitters PRS-S-NB9W PRS-H-NB9W Sanitary NB9W or NB15 Connection Head Pt100, Class A 3-A Approved, Clean-In-Place Mounting Flange, Standard & Heavy Duty Probes Food, Dairy & BioPharm Processes Transmitters PRS-S-CB PRS-H-CB Sanitary Stripped Leads Pt100, Class A Clean-In- Place Mounting Flange, Standard & Heavy Duty Probes Food, Dairy & BioPharm Processes PRS-TW-NB9W Sanitary Connection Head Pt100, Class A Spring Loaded Sensor in 3-A Approved Thermowell Food & Dairy Transmitters PRS-TW-M12 Sanitary M12 Connector Pt100, Class A Spring Loaded Sensor in 3-A Approved Thermowell Food & Dairy Transmitters & Cables UWRTD Sanitary and General Purpose Wireless Pt100, Class A Fixed Length Probe with Connection Head Mounted Wireless Transmitter, can be used with 3-A Aproved Thermowells General Purpose, Food, Dairy, BioPharm Wireless Receivers & Thermowells PRS-S-TMM12 PRS-H-TMM12 Sanitary M12 Connector Pt100, Class A 3-A Approved, Clean-In-Place Mounting Flange, Standard & Heavy Duty Probes Food, Dairy & BioPharm Processes Cables TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector M12C Extension Cables Extension Cables Molded M12 or M8 Connectors One End None Straight or Angled M12 or M8 Connector One End, Stripped Leads on the Other Sanitary, Food , Dairy BioPharm, General Purpose Field Installable Connectors PR-21 Immersion Sensor M12 Connector Pt100, Class A Straight Probe with or Without Monting Thread (NPT or Metric) and M12 Connector Automation, General Purpose, Thrermowell Mountable Cables, Compression Fittings, Transmitters

Transcript of RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction...

Page 1: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-3

RTD Selection Guide

Series No. Probe Type Termination Style† Element Features

Typical Applications

Options Available

PRS-S-M12 PRS-H-M12

Sanitary

M12 Connector

Pt100, Class A

3-A Approved, Clean-In-Place

Mounting Flange,

Standard & Heavy Duty

Probes

Food, Dairy & BioPharm Processes

Cables, Transmitters

PRS-S-NB9WPRS-H-NB9W

Sanitary

NB9W or NB15

Connection Head

Pt100, Class A

3-A Approved, Clean-In-Place

Mounting Flange,

Standard & Heavy Duty

Probes

Food, Dairy & BioPharm Processes

Transmitters

PRS-S-CB PRS-H-CB

Sanitary

Stripped Leads

Pt100, Class A

Clean-In- Place

Mounting Flange,

Standard & Heavy Duty

Probes

Food, Dairy & BioPharm Processes

PRS-TW-NB9W Sanitary

Connection Head

Pt100, Class A

Spring Loaded Sensor in 3-A

Approved Thermowell

Food & Dairy

Transmitters

PRS-TW-M12Sanitary

M12 Connector

Pt100, Class A

Spring Loaded Sensor in 3-A

Approved Thermowell

Food & Dairy

Transmitters & Cables

UWRTDSanitary

and General Purpose

Wireless

Pt100, Class A

Fixed Length Probe with

Connection Head Mounted Wireless Transmitter, can

be used with 3-A Aproved Thermowells

General Purpose,

Food, Dairy, BioPharm

Wireless Receivers & Thermowells

PRS-S-TMM12 PRS-H-TMM12

Sanitary

M12 Connector

Pt100, Class A

3-A Approved, Clean-In-Place

Mounting Flange,

Standard & Heavy Duty

Probes

Food, Dairy & BioPharm Processes

Cables

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

M12C Extension

CablesExtension

Cables

Molded M12 or M8 Connectors

One End

None

Straight or Angled M12 or M8 Connector

One End, Stripped Leads

on the Other

Sanitary, Food , Dairy BioPharm,

General Purpose

Field Installable

Connectors

PR-21Immersion

Sensor

M12 Connector

Pt100, Class A

Straight Probe with or Without Monting Thread (NPT or Metric)

and M12 Connector

Automation, General Purpose,

Thrermowell Mountable

Cables, Compression

Fittings, Transmitters

Page 2: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-4

C

Series No. Probe Type Termination Style† Element Features

Typical Applications

Options Available

TX94A-SSHeavy-Duty Transmitter

M12 Connector

to M12 Connector

None

TX94A Transmitter with Splash-Proof and

Heavy Duty Stainless Steel Housing; M12 Connection

Outdoor, Sanitary

and Marine Applications

Cables, Wall Mounting Bracket

SPRTX-SSIn-Line M12 Transmitter

Striped Leads

None

Connect to RTD Sensor Via an M12 Connector,

Provides 4 to 20 Milliamp

Signal

Provide Transmitted Signal with

Minimal Additional Hardware

Power Suplies,

Calibration

PR-22Immersion

Sensor

Molded M12 Connector

Pt100, Class A

Straight Probe with or Without Monting

Thread (NPT or Metric) and M12

ConnectorAutomation,

General Purpose,

Thrermowell Mountable

Cables, Compression

Fittings, Transmitters

PR-23 Immersion

Sensor

Molded M8 Connector

Pt100, Class A

Straight Probe with or Without

Monting Thread (NPT or Metric) and M8 Connector

Automation, General Purpose,

Thrermowell Mountable

Cables, Compression

Fittings

DTG-RTD100Digital

Indicator With Sensor

Various

Pt100

Backlit Point Of Use

Display, 316 Stainless Steel

Enclosure, Multiple Sensor

Configurations

Sanitary, Washdown,

Marine, General Purpose

Transmitters, Sensors, Cables

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

RTD Selection Guide

UWRTD-S-2Wireless

RTD Transmitter

M12 Connector to

Wireless

None

Connect an RTD Sensor

Using an M12 Connection

and Transmit the Sensor’s

Output

Remote Mounted,

Connects Via M12 Cable

Receivers

PRTF-10,-11 Straight Sheath and Transitioned

Sheaths with PFA Insulated, Fiberglass Insulated, SB Braided

or BX Armored CableStripped Leads

IEC 60751, DIN Platinum, Class B

Straight Immersion Probe

Process Measurement, Bath Temperature

Probe and Cable Length,

Sheath Diameter

PRTF-17, -13Miniature and

Standard Quick Disconnect Probe

MTP or OTPConnector

with Mating Connector

IEC 60751, DIN Platinum, Class B

Low Cost, Simple

Immersion Probe with Quick

Disconnect

Process

Measurement, Bath

Temperature

Probe and Cable

Length, Sheath Diameter

Page 3: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-5

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Probe Type

Termination Style† Element Features

Typical Applications

Options Available

PRTF-16Utility Handled

Probe

Stripped Leads

IEC 60751, DIN Platinum, Class B

Immersion Probe

with Molded Handle and Coil Cord

Hand Held Measurements

Sheath Length,

Sheath Diameter

Cut To LengthCut To Length

Probe

Stripped Leads

IEC 60751, DIN Platinum, Class B

Probe is Cutable to

Needed Length

Used in non-Immersion

Applications

Probe and Cable Lengths

PRSIntegral Plastic Handle Probes

Stripped Leads

IEC 60751, DIN Platinum, Class B

Air, Penetration, Fast Response

and General Usage Probes with Integral

Handles

Hand Held Measurements

Probe Style (Air, Penetration, Fast

Response and General)

PRTFCUFast Response

Copper Tip

Stripped Lead Wires

IEC 60751, DIN Platinum, Class B

Copper Tip for Fast Response to Temperature

Changes

Bearing Temperature, Low Contact

Measurements, Thermowells

Probe Diameter and Length,

Cable Length

PRTF-12,14,18,19Fixed Length Probe

with Head

Connection Head and Terminal Board

IEC 60751, DIN Platinum, Class B

Fixed Length Probe with Threaded

Mounting, Connection Head

and Terminal Board

Pipe and Pressure Vessel Measurements

Head Style, Probe Length, Transmitters

PRTF-12,14,18,19-SLSpring Loaded

Probe with Head

Connection Head and

Terminal Board

IEC 60751, DIN Platinum, Class B

Spring Loaded Probe with Threaded Mounting,

Connection Head and Terminal Board

Use With Thermowells or Machined

Housings

Head Style, Probe Length, Transmitters

RTD Selection Guide

PRTF-RPReplacement

Probesfor PRTF Sensors

Stripped Leads

Pt100, Class B

Spring Loaded and Fixed Length

Replacement Probes for

PRTF-12 and Other Connection

Head Styles

General Purpose

Probe and Cable Lengths

Page 4: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-6

C

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Probe Type Termination Style† Element Features

Typical Applications

Options Available

General Purpose 800

Series Class BGeneral Purpose

Sensors in 3-Packs

MTP Connectors with Mating Connector

IEC 60751, DIN Platinum, Class BVersions

Designed for Easy Installation

and Use

Measuring Surface,

Product and Structure

Temperatures

Factory Calibration

RTD 870/880Air, Gas and

Liquid Sensor With Bracket

Stripped Lead Wires

IEC 60751, DIN Platinum, Class B

Probes with Mounting Brackets

Appliance, Lab and Industrial

Uses

Factory Calibration

PR-15Immersion Probe with Ceramic

Terminal BlockTerminals

IEC 60751, DIN Platinum, Class B

Large Ceramic Screw Terminal

Block

Pipes or Duct Measurements

Factory Calibration

EWS-RTDWall Mount

Sensor

Stripped Lead Wires

IEC 60751, DIN Platinum, Class B

Sensor in a Plastic Wall Mountable Enclosure

Room Air Temperature Measurement

Extension Wire or Transmitter

BTTFExtruder Sensor

With Bayonet Fitting

Spade Lugs or OTP

Connectors

IEC 60751, DIN Platinum, Class B

Spring Loaded Bayonet Locking

Cap

Plastic Extrusion and Molding Equipment

Bayonet Adapters

RTD-2-Element With

Leads

Stripped Lead Wires

IEC 60751, DIN Platinum,

Class BSimple Surface

Mount Assembly

Measuring Surface Temps, Assembly into

Machined Housing

Element Size, Cable Type and

Length, Number of Wires

CFTFExtruder

Sensors with Compression

FittingsSpade Lugs or

OTP Connectors

IEC 60751, DIN Platinum, Class B

Straight or Bent with

Compression Fitting

Plastic Process Machinery

Sheath Bend

Page 5: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-7

RTD Selection Guide

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Probe Type Termination Style† Element Features

Typical Applications

Options Available

RTD-NPTPipe Plug RTD

MTP Connector with Mating Connector

IEC 60751, DIN Platinum, Class B

1⁄4 or 1⁄8 NPT Mounting

Fitting, SST Braided Cable

Pressure Vessels or Other Sealed

Systems

Lead Wire Length, Mounting Threads,

Single or Dual Element

SA2C-RTDSilicone Molded Surface Sensor

Stripped Lead Wires

IEC 60751, DIN Platinum, Class B

Pipe Mount or Flat Mounting, Self

Adhesive

Pipe or Surface Measurement

Connectors, Lead Lengths

SA1-RTDSelf-Adhesive

Surface Sensor

Stripped Leads or MTP Connectors

IEC 60751, DIN Platinum, Class B

Self Adheres to Most Surfaces,

Easy Installation and Use

Pipe, Surface or Structure

Measurements

Connectors, Lead Lengths

SRTDCement-On

Surface Sensor

Stripped Leads

100 Ω, DIN Platinum

Low Thermal Mass Provides Fast Response

Attach to Equipment,

Structures or Test Articles

Connectors, Lead Lengths

Extension Cords & CableExtension Cords

Stripped Leads or Connectors

None

Straight and Coiled Configurations,

Multiple Connector Offerings

Extend RTD Wiring

Connectors, Lead Lengths

HSRTDHermetically Sealed Wire

Sensor Assembly

Stripped Leads

IEC 60751, DIN Platinum, Class B

Hermetically Sealed Tip, Corrosion Resistant

Plating Baths, Laboratories

Cable Length, Connector

PR-10, 11Straight Sheath and

Transitioned Sheaths with PFA Insulated and

Jacketed CableStripped Leads

IEC 60751, DIN Platinum, Class A

Straight Immersion Probe

Process Measurement, Bath Temperature

Probe and Cable Length, Sheath

Diameter

Page 6: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-8

C

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Probe Type Termination Style† Element Features

Typical Applications Options Available

P-M, P-LUltra-Precise for Immersion Applications

Stripped Lead Wires

100 Ω DIN Platinum

Class A, 1⁄3 DIN or 1⁄10 DIN

Straight Probes with or Without

Mounting Fittings

Test Labs, High Accuracy

Processes

Mounting Fittings, Probe Lengths and Diameters,

Resistance Tolerances

PR-11, 13, 16, 17 1.5 mm Fine

Diameter ProbesQuick Disconnect,

Handle or TJ

OTP / MTP Connectors, Handle or Stripped Leads

IEC 60751, DIN Platinum, Class A

Retractable Cable, Molded

Handle Grip

Handheld Meters

Factory Calibration

PRXRemovable

Handle and Probe

Handle Probe with Stripped

Leads Standard

IEC 60751, DIN Platinum, Class A

Removable Probe

Soft Solids & Fluids

Measurements

Factory Calibration

PR-16Utility Handle

Probe

Stripped Leads Standard

IEC 60751, DIN Platinum, Class A

Retractable Cable, Molded

Handle Grip

Handheld Meters

Factory Calibration

PR-PFAPFA Coated

Probes

Connectors, Heads, Stripped Leads

IEC 60751, DIN Platinum,

Class A and B

PFA Coating Provides Protection to Sheath in Corrosive

Environments

Plating Baths, Acid Baths, Corrosive

Environments

Factory Calibration

PR-17, -13Miniature and

Standard Quick Disconnect

Probe

MTP or OTPConnector

with Mating Connector

IEC 60751, DIN Platinum, Class A

Simple Immersion Probe with Quick

Disconnect

Process Measurement,

Bath Temperature

Probe and Cable Length, Sheath

Diameter

PR-12,14,18,19 Fixed Length

Fixed Length Probe with Head

Connection Head and Terminal Board

IEC 60751, DIN Platinum, Class A

Fixed Length Probe with Threaded Mounting,

Connection Head and Terminal Board

Pipe and Pressure Vessel Measurements

Head Style, Probe Length, Transmitters

Page 7: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-9

RTD Selection Guide

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Probe Type Termination Style† Element Features

Typical Applications

Options Available

PR-12,14,18,19 Spring LoadedSpring Loaded

Probe with Head

Connection Head and Terminal

Board

IEC 60751, DIN Platinum, Class A

Spring Loaded Probe with Threaded Mounting,

Connection Head and

Terminal Board

Pipe and Pressure Vessel Measurements in

Thermowells

Head Style, Probe Length, Transmitters

RTD-800 SeriesGeneral Purpose SensorsStripped Leads,

Connectors

IEC 60751, DIN Platinum,

Class A

Flexible Mounting Options

Surface, Air and Immersion Measurements

Factory Calibration, Hand Held

Meters

SA1-RTDSurface Sensor

Stripped Leads

IEC 60751, DIN Platinum,

Class ASelf-Adhesive Mounting or Cement In

Place

Surface Measurements on Structures,

in Processes or For Testing

Stainless Steel Braid, Connectors

RTD-2Element

With Leads

Stripped Lead Wires

IEC 60751, DIN Platinum,

Class A

Simple Surface Mount Assembly

Measuring Surface Temperatures, Assembly into

Machined Housing

Element Size,

Cable Type and Length, Number

of Wires

BT and CFBayonet Cap and Adjustable Fitting

Mountable

Spade Lugs or Connectors

IEC 60751, DIN Platinum, Class A

Straight or Bent with Compression

Fitting

Plastic Process Machinery

Sheath Bend

PRCUFast Response Copper Tipped

Stripped Leads

IEC 60751, DIN Platinum, Class A

Copper Tipped Sensors Provide Faster Response to Temperature

Changes

Thermowells, Surface

and Bearing Temperature

Measurements

Connectors, Heads & Fittings

PR-RPReplacement

Probes for PR Sensors

Stripped Leads

Pt100, Class A

Spring Loaded and Fixed Length

Replacement Probes for

PR-12 and Other Connection Head Styles

General Purpose

Probe and

Lead Lengths

-CL1/3 and -CL1/10

RTD Elements

Bare Leads

Pt100 Wire Wound

High Accuracy Wire Wound

RTD Elements with Class 1/3DIN and

1/10DIN Tolerances

High Accuracy

Measurements

Lead Wire Attachment

Page 8: RTD Selection Guide - OMEGA Engineering | … · C-7 RTD Selection Guide TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector †Stripped lead connection style

C-10

C

TJ = Transition junction to lead wires OTP = Standard Three-Prong Connector† Stripped lead connection style can be supplied with connectors on request MTP = Miniature Three-Prong Connector

Series No. Features Element with Bare Lead Wire

Termination Style

F (OEM)OEM

Applications Vibration Resistant

Single Thin Film Flat and

Cylindrical Ceramic

2 Leads

FFast

Response

Single Thin Film Flat

2 Leads for Welding

FRLong Term

Stability

Single or Dual Thin Film Cylindrical

2 or 4 Leads Welding

WResistance to

2000 Ω

Single Thin Film Cylindrical

2 Leads for Welding

KNClass A

Accuracy

Single or Dual Wire Wound

Ceramic

2 or 4 Leads for Welding

KN Class AClass A

Accuracy

Single or Dual Wire Wound

Ceramic

2 or 4 Leads for Welding

G, GX, GNVibration Resistant

Single Wire Wound Glass

2 Leads for Welding

F Class BLong Term

Stability 5-pack

Single or Dual Thin Film Cylindrical