RRU OUTDOORSCHEDULE

56
S.No DESCRIPTION Unit Sch Qty Rate Amount SCHEDULE-A 1 SET 66 29083.59 1919516.94 RITES 2 Nos 200 1269.7 253940 RDSO 3 SET 11 26475.63 291231.93 RITES 4 NO 1000 367.74 367740 RDSO 5 SET 5 449966.11 2249830.55 RDSO Name of work : Supply, Installation, Testing and Commissioning of Panel Interlocking work at 05 stations (DWI,SWC, - Manikpur section of JHS division. Insp. agency Supply of Relay Rack Assembly powder coated complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay, plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on the division. Typical part list as per Annexure and Rack Supply of Tag Blocks 200 way with cover as per IRS:S- 77/2006 (Rev.1) with Drg.NO.SA-24751,52,53 or latest. Supply of Main Cable Termination rack powder coated complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners (backelite strips) etc. Siemens type & as per extant practice on Supply of 8-Way Terminal strips, made of PBT, isolating barrier type as per RDSO SPN No IRS-S-79/92 Amdt.2 & Drg No 24811, 24812 (Alt.2) with latest amendement or of Supply of Data logger for monitoring status of important relays, complete with Processor Module to monitor 512 digital and 32 analog inputs as per spec. RDSO/SPN/99/06 with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module as per Annexure, shall be placed in Standard rack of suitable size to be supplied by the contractor.this includes supply of 2 nos of PCs Window-7 with colour monitor,UPS & printer each as per annexure. This also includes Installation, wiring, testing, and commissioning of data logger complete along with door closing magnet etc.of R/room and networking arrangement with Jhansi Test room on the channel provided by the

Transcript of RRU OUTDOORSCHEDULE

Page 1: RRU OUTDOORSCHEDULE

S.No DESCRIPTION Unit Sch Qty Rate Amount Insp. agency Rate Reference

SCHEDULE-A 1 SET 66 29083.59 1919516.94 RITES

2 Nos 200 1269.7 253940 RDSO

3 SET 11 26475.63 291231.93 RITES

4 NO 1000 367.74 367740 RDSO

5 SET 5 449966.11 2249830.55 RDSO

Name of work : Supply, Installation, Testing and Commissioning of Panel Interlocking work at 05 stations (DWI,SWC,BUS,CKTD & KHOH) in Banda - Manikpur section of JHS division.

Supply of Relay Rack Assembly powder coated complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay, plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on the division. Typical part list as per Annexure and Rack arrangement as per standard Drg.& sketch SK-727/A of N.C.Rly.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-1

Supply of Tag Blocks 200 way with cover as per IRS:S-77/2006 (Rev.1) with Drg.NO.SA-24751,52,53 or latest.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-2

Supply of Main Cable Termination rack powder coated complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners (backelite strips) etc. Siemens type & as per extant practice on the division. Typical part list as per Annexure and rack arrangement shall be as per standard Drg.& sketch SK-727/B of N.C.Rly.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-3

Supply of 8-Way Terminal strips, made of PBT, isolating barrier type as per RDSO SPN No IRS-S-79/92 Amdt.2 & Drg No 24811, 24812 (Alt.2) with latest amendement or of latest RDSO Specification .

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-4

Supply of Data logger for monitoring status of important relays, complete with Processor Module to monitor 512 digital and 32 analog inputs as per spec. RDSO/SPN/99/06 with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module as per Annexure, shall be placed in Standard rack of suitable size to be supplied by the contractor.this includes supply of 2 nos of PCs Window-7 with colour monitor,UPS & printer each as per annexure. This also includes Installation, wiring, testing, and commissioning of data logger complete along with door closing magnet etc.of R/room and networking arrangement with Jhansi Test room on the channel provided by the railways with all accessories and Contractors own material. This includes programming of data logger for fault diagnostic in suitable structured language in consultation with Rly.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-5

Page 2: RRU OUTDOORSCHEDULE

6 SET 1 162871.8 162871.8 RDSO

7 SET 10 271643.02 2716430.2 RITES

8 No 2 248176.26 496352.52 RITES

Supply & installation of remote terminal unit cum event logger for 64 Digital and 16 Analog input cards and power supply unit as per specification no. IRS S 99/2006 or latest with latest amendments from RDSO approved firm. This also includes supply of dual card leased line modem for connecting nearest datalogger. This also includes installation, testing & commissioing of RTU and modems.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-6

Supply of Single phase 10 KVA silent DG set of reputed firms like Mahindra, Kirloskar, Cummins make (as per CPCB norms) with sound proof enclosure (enclosure fabricated out of best quality steel sheet and insulated with highly sound absorbant material) complete with diesel tank of adequate capacity along with 88 AH, 12 V dry battery, battery charger upto 10Amp of ex-serviceman make or similar as per specn. No. IRS S-86-2000 suitable for charging the battery at site, control panel, remote operation system (complete) suitable to start & stop the DG set with push buttons from ASM's office, anti vibration cushion foot mounting along with all accessories as per specification no. IRS S 69-86 or latest with latest amendments.This also includes diesel for generator for testing purpose till commissioning of station & battery maintenance for a period of six months after N.I.period.

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-6

Supply of Single phase 5 KVA silent DG set of reputed firms like Mahindra, Kirloskar, Cummins make (as per CPCB norms) with sound proof enclosure (enclosure fabricated out of best quality steel sheet and insulated with highly sound absorbant material) complete with diesel tank of adequate capacity along with 88 AH, 12 V dry battery, battery charger upto 10Amp of ex-serviceman make or similar as per specn. No. IRS S-86-2000 suitable for charging the battery at site, control panel, remote operation system (complete) suitable to start & stop the DG set with push buttons from ASM's office, anti vibration cushion foot mounting along with all accessories as per specification no. IRS S 69-86 or latest with latest amendments.This also includes diesel for generator for testing purpose till commissioning of station & battery maintenance for a period of six months after N.I.period.

JHS/S&T/C/Tender/08dtd 27.02.08 Item no, A-11

Page 3: RRU OUTDOORSCHEDULE

9 SET 1 387000 387000 RITES

10 SET 1 225000 225000 RITES

11 NO 5 39564.00 197820 RITES

12 NO 1 28436.62 28436.62

13 NO 6 66011.5 396069 RDSO

Supply of prefabricated signaling and equipment housing having outer dimension of 6000x3000x3080 mm made of 80 mm thick polyurethane foam sandwich panel for equipment/Relay room complete with doors elestomeric waterproofing, ventilators, exhaust fans etc. sun/rain guard, PVC flooring, Twin tube lights, fans etc. as per technical specification mentioned in Annexure-2. Manufacturers test and guarantee certificate to be submitted by the contractor. This also includes excavation of trenches for foundation and construction of foundation as per technical specification, erection, fixing of pre-fabricated building with all accessories supplied in items above on the foundation erected. All materials, including cement & steel to be supplied by the contractor. Double locking arrangement to be provided in the door of relay room.

S&T/NCR/JHS/15 Dated 08.12.2008 Item No 2 At PAR as LAR

Supply of prefabricated signaling and equipment housing having outer dimension of 3000x3000x3080 mm made of 80 mm thick polyurethane foam sandwich panel for equipment/Relay room complete with doors elestomeric waterproofing, ventilators, exhaust fans etc. sun/rain guard, PVC flooring, Twin tube lights, fans etc. as per technical specification mentioned in Annexure-2. Manufacturers test and guarantee certificate to be submitted by the contractor. This also includes excavation of trenches for foundation and construction of foundation as per technical specification, erection, fixing of pre-fabricated building with all accessories supplied in items above on the foundation erected. All materials, including cement & steel to be supplied by the contractor. Double locking arrangement to be provided in the door of relay room.

S&T/NCR/JHS/15 Dated 08.12.2008 Item No 1 At PAR as LAR

Supply of automatic change over control panel for colour light signaling panel, three independent single phase 230V AC, 50 Hz supplies of 63A capacity as per RDSO Specn. No. TI/SPC/PSI/CLS/0023 with latest amendment (drawing no.ETI/PSI/43(10/90) for 3 line PI station with facility of indication to ASM.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-7

Supply of automatic change over control panel for colour light signaling panel, three independent single phase 240V AC, 50 Hz supplies of 32A capacity as per RDSO Specn. No. TI/SPC/PSI/CLS/0023 with latest amendment (drawing no.ETI/PSI/035-4) for LC gate with facility of indication to Gateman.

CONSIGNEE

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-8

Supply of Battery Charger self regulating floor mounting type with 230V AC single phase input and output 110V DC 40 A as per IRS:S-86/2000 with Amendment – 4 or latest.

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-8

Page 4: RRU OUTDOORSCHEDULE

14 SET 5 1108018 5540090 RDSO

Mounting structure with hardware and field junction box.15 SET 1 459513.88 459513.88 RDSO

Mounting structure with hardware and field junction box.16 SET 22 23392.21 514628.62

(a)

(b) Earth enhancement material supplied in sealed bags of minimum 10 kgs. 3nos

(c) Copper strip 150X25X6mm to terminate earth end -1nos.

17 SET 1 116791.26 116791.26 RDSO

Supply installation, testing & commissioning of Solar Photo voltaic sytem for P.I. systems for charging battery bank

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-11

Solar panel voltic Module of 12V,70W +/- 5% as per RDSO specification No. IRS-S-84/92(Amd.2) or latest (9 in series & 10 in parallel= 90 nos for one set.

Supply, installation, testing & commissioning of Solar Photo Voltaic System for LC Gate for charging battery bank of 110V/300AH as per RDSO Specification no. IRS-S- having nominal voltage 110V & consisting of following.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-9

Solar Photo Voltaic Module of 12V, 70W +/- 5% as per RDSO Specification no. IRS-S-84/92 (latest) ( 9 in series & 4 in parallel = 36nos.for one set)

Supply & installation of basic material to construct unit maintenance free earth consisting as per RDSO Spec. no. RDSO/SPN/197/2008 consisting of following items :-

RITES/ RDSO

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-55

Copper bonded steel electrodes of 3.0m long, 17.2mm dia with copper bonding thickness of min 250 micron and UL listed and marked.1 no

This includes digging the earth to the required depth, insertion of electrode, Filling of earth enhancing compound (30 Kg), provision of exothermic weld connection on copper tape of 25mm X 6mm X 150mm to the earth electrode, all the material tools & features required for the weld to be arranged by the contractor, Provision of exothermic weld connecting, one to connect 35sqmm multi strand single core PVC insulated copper cable welded to the copper tape welded to the earth electrode and another to the copper tape to be fixed inside the equipment.relay rack/apparatus room. (features for mounting the copper tape inside the relay room, weld materials, tools & features required for the weld to be arranged by the contractor, Electrodes termination in a concrete sink and routing the cadmium cable to bus bar in equipment room. (All other materials required for the work shall be borne by the contractor).

Supply of 4 wire V.F. cable Repeater equipment (4 way Amplifier) INDISCO make along with U-Link panel, rack and power supply including battery and Battery charger ( At stations where there is no Electricity this charger will be of solar type with adequate capacity to charge the Batteries). as per specification for equaliser ,amplifier, repeater equipement, each repeater will be equipped with 4 amplifier equalisers and U-link and isolation transformer sufficient for all 6 quad.

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-66

Page 5: RRU OUTDOORSCHEDULE

18 Nos 5 88780.68 443903.40 RDSO

19 Nos 300 2315.28 694584 RDSO

20 Nos 150 3967.97 595195.5 RDSO

21 Nos 150 5025.51 753826.5 RDSO

22 Nos 5 10183.77 50918.85 RDSO

23

(a) 5F-3B contact configuration or equivalent Nos 1000 5084.27 5084270 RDSO

(b) 4F-4B contact configuration or equivalent Nos 300 5084.27 1525281 RDSO

24 Nos 200 5084.27 1016854 RDSO

25 Nos 40 30132.43 1205297.2 RDSO

26 Nos 10 36608.27 366082.7 RDSO

27 Nos 25 36374.35 909358.75 RDSO

28 Nos 20 41798.08 835961.6 RDSO

Supply of ELD with 8 Channels for monitoring AC channel and DC channel 110 v AC and 4 channel cord for monitoring DC Voltage (24 V,60 V,110V) as per RDSO specification no. RDSO/SPN/256/2002 or latest .

JHS/N/21/11/Inter/18LC/A&D Rt dt. 06.01.2012 Item No A-39

Supply of Relay AC immunized, DC miniature plugin neutral line tractive armature, 24V DC 8F - 8B contacts, front and back contacts metal to carbon complete with plugboard, retaining clip & connectors PIN code AEDGH confirming to BRS : 931, IRS:S 23 & 34 as applicable with latest amendment. Type QNA1 with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-12

Supply of QSPA1, 24VDC,Slow to pick up,8F.4B along with plug board,retaining clip and connectors conforming to BRS: 930, 931A, 932A, 933A, 934A, 935A, 937A, 943, 960 & RDSO/SPN/84/88 or latest with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-13

Supply of QTA2,9 Ohm,2F.1B, relay along with plug board,retaining clip and connectors conforming to BRS:938A,939A, BRS:966,Appendix F2 IRS:S34 & IRS:S23 or latest with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-14

Supply of fail safe electronic flasher device workable on 24V DC as per specn no. RDSO/SPN/173/2002 with amdt. No.1 or latetst (with galvanic isolation)

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-10

Supply of Plug In type Relay Metal to Metal type neutral relay mini groups ( Non AC Immunised) Siemens make (No. RSSK 30/0011) or equivalent (Ref. IRS:S46) with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-25b

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-25c

Supply of Plug In type Relay interlocked Siemens make4F/4B (No. RSSK 30/0012) or equivalent (Ref. IRS:S46) with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-27b

Supply of Signal Group 2 Aspect with LED ECR Siemens Make or similar with base. Type A - RT - RG AO66

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-17

Supply of Signal Group, 3 Aspect with LED ECR Siemens Make or similar with base. Type A - RT - RG AO67

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-18

Supply of Shunt Signal Group with LED ECR Siemens Make or similar with base. Type A - RT - RG AO65

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-19

Supply of Route Group Siemens Make or similar ( No RSSK 31/0002) or latest & suitable for working with LED signals with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-20

Page 6: RRU OUTDOORSCHEDULE

29 Nos 35 50606.6 1771231 RDSO

30 Nos 10 24096.15 240961.5 RDSO

31 Nos 60 5914.42 354865.2 RITES

32 Nos 30 5962.29 178868.7 RITES

33 Nos 75 5309.01 398175.75 RDSO

34 Nos 10 5714.22 57142.2 CONSIGNEE

35 Nos 10 2337.04 23370.4 CONSIGNEE

36

Supply of Point Group RRI, Siemens make or similar (No RSSK 3515/19) with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-21

Supply of Point chain Group RRI, Siemens make or similar (No RSSK 3515/3) with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-22

Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052)or equivalent with base.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-23

Supply of Key Lock Relay with different ward combinations (one ward to be supplied with relay and Two nos wards to be supplied with same ward configuration with each relay.). Siemens Make working on 60V DC or equivalent. Note: 'A' ward not required.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-24

Universal plug in typr AC Lamp proving relay(Metal To Metal) for 110 V AC LED signal lamp as per SPN.No.STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 No. IRS:S:23 AS PER DRG A-RT-RG-A-064 (Siemens make) with base.

PO No. 55.11.5058.1.89557 Dt. 20.12.2012

Supply of Wooden block counter of size 900mm x 700mm X 700mm made of good quality wood frame and 3mm thick water proof ply with formica finish on top and all four sides having two compartment inside and two doors on opposite sides as per Drg No. JHS/S&T/Wks-II/103

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-28

Supply of Desk type Electronic Magneto Telephone push button type as per RDSO spec No IRS:TC 79/2000 with Amendment no.2 or latest.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-29

Supply of LED type, Indication cum Operating Panel with tag blocks, wires, angle iron etc.depicting the yard layout with signals, points, track circuits, operating/emergency push buttons, counters with sealing arrangements, digital ampere meter and SM's key housed in a steel metal/sunmica cabinet conforming to RDSO Drg No.S11610 made of exchangeable domino units each of size typically 54x34 mm. Panel shall be supplied completely wired & soldered alongwith panel tag block analysis. Control panel diagram shall also be supplied by the contractor. All fused LEDs shall be replaced by contractor during testing period. 10% (minimum one) of buttons, counter and LEDs of each colour shall be handed over as spare after commissioning of the installation by the contractor. Tag block shall conform to RDSO specn IRS:S-77/2006 (Rev.1) or latest with Drg.NO.SA-24751,52,53. LED should work on 24V. 2 magnets, 2 fully wired domino units, 1 buzzer & 4 bulb extractors shall also be handed over as spare.

Page 7: RRU OUTDOORSCHEDULE

(a) Panel size 40 domino X 15 domino Nos 5 159172.59 795862.95 RITES

37 Supply of Test Board for relay room as per Drg No JHS/S&T/Wks-II/102 Nos 6 3895.07 23370.42 CONSIGNEE

38 Nos 5 20910.94 104554.7 CONSIGNEE

39 Nos 10 10414.43 104144.3 CONSIGNEE

40 Supply of Chair Model PCH 7001 (Godrej)or similar. Nos 5 10026.42 50132.10 CONSIGNEE

41 Nos 10 2318.62 23186.2 CONSIGNEE

42 No 1 243203.21 243203.21 RITES

43

(a) 4.5 Mtr long post Nos 15 16125.39 241880.85 RITES

(b) 5.5 Mtr long post Nos 10 14911.17 149111.7 RITES

The panel should be covered with perspex sheet on the top to avoid damage to the panel while in service. (One row each of dummy dominos to be provided on top & Bottom of the panel. One sheet of perspex sheet 3mm thick size 1200x2400 mm to be supplied as spare.This also includes fabrication,screen /Flex printing of SWR board on white formica of requisite size and its fixing)

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-30

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-31

Supply of Office Almirah of size 900W x 1168.5H X 450D mm as per model no.KD minor with metal top of Godrej make or Similar.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-36

Supply of Table Model of size 1370W x 690D x 740H mm as per model no.T-9 of Godrej make or Similar.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-37

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-38

Supply of chair superior quality with arm and can seated of size 57D X 58W X 88H & Seat height of 45mm [Godrej Make & model no.Classic CH-7 or similar].

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-39

Supply of cable fault locator in the underground cable as per model no. TFL-5B of M/s APLAB stanlay TS-90 or similar branded make.

JHS/N/21/11/Inter/18LC/A&D Rt dt. 06.01.2012 Item No A-56

Supply of Main Signal Post 140 mm outer dia as per spec No IRS S 6/81 with latest amendments along with Cast Iron Main signal surface base 140mm as per spec No IRS S 10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal long as per RDSO Drg. No. SA-23156. & signal front staging complete assembly for CLS unit as per Drg.No RST/11413 & signal back staging as per extant practice on the division .

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-41a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-41b

Page 8: RRU OUTDOORSCHEDULE

44 Nos 10 1754.96 17549.6 RITES

45 Supply of offset bracket(a) for main signal (5.5" dia) Nos 10 1815.88 18158.8 RITES

(b) for shunt signal (3.5" dia) Nos 30 1024.9 30747 RITES

46 Nos 130 484.16 62940.8 CONSIGNEE

47 Supply of following CLS signal Unit :

(a) CLS Unit 2 Aspect as per RDSO No. SA25003/A/M Nos 10 19160.94 191609.4 RITES

(b) CLS Unit 3 Aspect as per RDSO No. SA25002/A/M Nos 20 26565.94 531318.8 RITES

(c) Position light shunt signal Unit.as per RDSO No. SA23840 (Adv) Nos 10 6739.13 67391.3 RITES

(d) Calling ON Unit as per RDSO Drg no 24351(Adv.)Alt1 Nos 10 5356.27 53562.7 RITES

48 Nos 10 21469.7 214697 RITES

49 Nos 20000 64.19 1283800 RDSO

50 Nos 200 121.85 24370 RDSO

51

Supply of Shunt Signal Post with Base (GI Pipe B class of 80 mm Dia as per spec. No.IS 1239 PT. 1/1990, 1 Mtr length).

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-42

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-43a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-43b

Supply & installation of Signal No.plates. as per Drg No RST-11393, C/P/G BOARDS plates as per Drg No RST-11394. and instt. as per drg no. JHS/S&T/Wks-II/107

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-44

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-47a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-47b

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-47c

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-47d

Supply of 2 Way Junction Route Indicator as per RDSO Drg.No. SA23401-6 (Adv) and IRS-S-66/84Amd.I

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-48b

Supply of ARA Terminal Block made of PBT as per IRS:S-75/2006 (Rev.2) & Drg.no. SA- 23756 (Alt-3) with latest amendments along with disconnecting links as per Drg no. RST/11336. .

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-51

Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23756 (Alt 3) & Spec No IRS 75/2006 (Rev.2) with latest amendment. Fuse block shall be suitable for round head type voltage fuses.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-52

Supply of Apparatus cases with miniature E Type Locks with keys as per spec. No IRS S 30/64 & RDSO Drg. No. SA 3376 with latest amendments (for E type lock).

Page 9: RRU OUTDOORSCHEDULE

(a) Single case as per Drg No WS-8842/A with latest ammendment. Nos 200 13045.23 2609046 RITES

(b) Half Case as per Drg No.WS-8842/A with latest ammendment. Nos 30 9921.56 297646.8 RITES

52 Nos 100 4693.67 469367 RITES

53 Nos 500 64.19 32095 CONSIGNEE

54 SET 10 280800 2808000 RDSO

55 Nos 350 1296.9 453915 RITES

56 Nos 500 1767.18 883590 RDSO

57 Nos 150 2738.64 410796 RDSO

58 Nos 150 907.40 136110 RDSO

59 Nos 150 1857.23 278584.5 RDSO

60 Nos 75 195.84 14688 CONSIGNEE

61 Nos 6 7461.57 44769.42 CONSIGNEE

62 SET 20 214.33 4286.6 CONSIGNEE

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-53a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-53b

Supply of Hylam sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1974.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-50

Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments. Capacity 6A/10Amps.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-40b

Supply of Diado Single Line Handle type Tokenless Block instrument as per RDSO specn.no.IRS:S-98/2001 (Amd.3) with latest amendments.

PO NO 55.10.5097.1.89532 Dt.11.07.2012

Supply of Track Lead Junction Boxes as per Drg. No. SA 20101/M made from fibre glass alongwith terminal blocks.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-56

Supply of low maintenance Lead Acid Secondary Cells 2V 80 Amp Hr. as per spec. RDSO IRS S 88/2004 with latest amendments.

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-54

Supply of B type choke as per IRS S 65/83 Amendment 1 with latest amendments if any

JHS/S&T/C/Tender/08dtd 27.02.08 Item no, A-61

Supply of adjustable Track Feed Resistance 30 ohms as per RDSO Drg. No. SA 20166/M (Adv) with latest amendments (with Phenolic moulded base).

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-57

Supply of Track feed battery chargers, 110V AC input & Output suitable for charging upto 4 cells and with charger failure alarm to Specn.No.IRS.89/93 Amendment 3 with latest amendments. Charger shall be suitable for charging 80 AH battery.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-58

Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-59

Supply of Crank Handle cum key lock relay box powder coated alongwith LEDs, TEKNIC make push buttons, 8-way terminal strips, string rod, etc. as per Drawing No.RST/C/111/A/B

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-61

Supply of william stretcher insulation set (complete set) to suit point layout as per RDSO Drg No SA 9151-52.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-62

Page 10: RRU OUTDOORSCHEDULE

63 SET 20 214.33 4286.6 CONSIGNEE

64 SET 20 6285.43 125708.6 RITES

65 MTR 1500 349.25 523875 RITES

66 MTR 800 629.30 503440 RITES

67 Job 5 3647.84 18239.2 CONSIGNEE

68 SET 7 276394.79 1934763.53 RDSO

69 Nos 6 6744.57 40467.42 CONSIGNEE

Supply Gauge Tie plate insulation as per RDSO drg No: T- 10372Alt2, T- 10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with latest amendements..

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-64

Supply of Ground connections, complete set suitable for IRS/Siemens Make point Machine for ordinary turnout with tongue attachment insulation as per RDSO Drg. S 3361-62-63 or latest suitable for IRS:24/2002 pt machines. However the ground connection shall be procured only after confirmation from Railway engineer as per latest site condition /type of machine available in depot.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-65

Supply of Double Walled Corrugated pipe made up of Polyethylene of Size 103.5 mm inner dia and 120mm outer dia in 6 M straight length as per British standard No BSEN 50086-1 and BSEN 50086-2-4 and BIS draft spec Doc No ETD 14 (5071) AND etd 14(5072) along with one coupler per every 6 meters.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-67

Supply of perforated GI pipe, 100 mm bore dia,B class perforated at interval of 300 mm with 10 mm dia hole with staggering 0.3 mtrs approx.

JHS/S&T/C/Tender/08dtd 27.02.08 Item no, A-74

Supply,fixing & commissioning of progress board made of 12mm ply with sunmica and LED with holder as per required sizeas per Drg. No. JHS/S&T/Wks-II/101

JHS/S&T/C/Tender/08dtd 27.02.08 Item no, B-9

Supply of electrically operated lifting barrier assembly each consisting of 2 Nos of electrically operated lifting barriers, 2 Pedestal, 8 band circuit controller with limit switch, hand cranks, 2 electric motors 110 volts AC 0.5 HP without centrifugal switch, 2 aluminium boom in 4 sections of 8 feet long each, with 2 stop boards, boom light boxes, CI counter weights and 2 no of boom support for resting boom and boom locking assembly along with gate control cum gate indication panel on sheet metal fabricated box with switches and buttons to operate the gate as per IRS S41/70 (Amd.2) or latest except (a) motor current is max. 5Amps. for 0.5 HP motor & motor confirms to IS-996. (b) Elmex terminal to be used instead of M-5 terminals.(c)Circuit controller should have CAM operated Siemens limit switches instead of wiping type contacts. Crank handle arrangement wll be as per Railway's requirement. The movement of the boom over 85 degrees to be restricted mechanically.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-68

Design, supply & installation of Level crosiing Signal control cum indication panel with LED bulb of 16 SWG powder coated MS sheet of size 39 cm x 24 cm x 10 cm approx. consisting of different colour LEDs with holder to work on 24 V DC. Description on front panel to be taken from Rly.As per Drg No.JHS/S&T/W/JHS-18

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd . 19.01.2012 Item No. A-69

Page 11: RRU OUTDOORSCHEDULE

70 Nos 1 6621.83 6621.83 CONSIGNEE

71 Nos 10 335754.51 3357545.1 RDSO

72 Nos 125 1943.48 242935 RITES

73 Supply of Tool box complete as per Annexure Set 2 72348.31 144696.62 CONSIGNEE

74Job 5 9904 49520 CONSIGNEE

75 Nos 20 1319.75 26395 CONSIGNEE

76 Nos 5 18259.56 91297.8 CONSIGNEE

TOTAL Of SCHEDULE A 52573689.421

SCHEDULE-B1 Nos 66 1369.8 90406.8

2 Nos 11 1105.41 12159.51

Design, fabrication and supply of Gate Indication cum 4 switch operating panel made of 16 SWG powder coated MS Sheet of size 39 cm x 24cm x 10 cm (approximately) consisting of different colour LEDs with holders suitable to work on 24 V DC to 28 V DC supply. Indications on the front face of the panel will be provided as per typical diagram given by Railways. There may be some changes in the typical diagram based on site condition which will be advised by the engineer incharge of the work which has to be confirmed before carrying out the work of screenprinting the indication of the panel. All description on the front panel are to be screeprinted.

JHS/N/W/21/11/Inter/18LC/A&D Rt dt. 06.01.12 Item no. 48

Supply,installation,testing commissioning of single section digital axle counter system as per RDSO specn. No. RDSO/SPN/177/2005 (Version-2) with amendment 1 (Phase reversal type)

PO NO 55.10.5021.1.89524 Dt.09.08.2010

Supply of heat Shrinkable Straight through Jointing kit TSF-3 for 6Quad Cable as per RDSO specifications IRS/TC/-77/2006 (Rev.1) Amdt.1 or latest of RAYCHEM/REPL MAKE.with Mfd. after July'13

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-64

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. A-35

Supply & installation of PPTC Fuses Fuzetec make PTC Resettable Fuse various types as per requirement & instruction of site incharge.

As per price offer of M/s Enerdyne devices Pvt Ltd Noida dated 20.02.13

Supply of Boards for drawing driver ahead to occupy calling on track circuit (Calling on instruction board)/Entering MACLS Teritory/Entering Tokenless Block Teritory as per requirement.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. A-46

Supply of VHF mobile synthesized transreceiver 25 watt complete . Motorolla make or similar.

JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 A-33

Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. This will also include the supply & fixing of indicative type of fuse with inserts of required capacity. The work shall be done as per approved plan, extant practice on the division & the instructions of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-1

Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminal, 96 way tag block & other necessary accessories etc. The work shall be done as per approved plan, extant practice on the division & the instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-2

Page 12: RRU OUTDOORSCHEDULE

3 Per KVA 110 600.58 66063.8

4 66 8741.07 576910.62

5 66 984.64 64986.24

6 Per Stn. 5 2597.07 12985.35

Installation of DG set. This includes casting of vibration free foundation, installation of panel outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of panel, laying of cables/wires should be carried out in HD PVC channel/conduit file. This includes cost of all materials required for charging of battery and installation except DG set panel. Wires/cables should be as per extant practice on the division and instruction of Railway engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-4

Fixing of metal to carbon relay base plate/ Metal to Metal relay mini group and major group base plates, laying, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. Wiring of circuits to be done as per the approved diagram based on relay interlocking system using metal to metal/metal to carbon type relays and soldering after testing. This also include fuse wiring, fuse blown off indication, function wiring (interconnection between relay rack & CT rack). Contractor to supply materials required like jumper wires, solder resin core, lacing/adhesive tapes, diodes, resistances, condensers, LEDs & lugs etc. at his own cost.All materials required to be supplied and used by the contractor should be got inspected by consignee before being put to use. The jumper wires like .6mm,1mm,16/.2 etc. should be procured from RDSO approved source whereever available. The purchase certificate to be presented to the consignee. The work shall be done as per approved plan, extant practice on the division & the instruction of Rly engineer at site.

PER RACK

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-5

Installation of metal to carbon relay, Metal to Metal relay/relay groups. Energisation of the system, making the panel through, functional test as per control table with contractor's own mock panel, break test if applicable in presence of Rly. Engineers. This will include wiring alterations requied if any at that stage, preparation and submission of wire count detail register etc. The work shall be done as per extant practice on the division& the instruction of Rly engineer at site.

PER RACK

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-6

Installation wiring and shifting of block instrument , control phones, gate phones, VHF repeater etc. The work of wiring right from Telecom DP to block Instrument, Control phones , shifting of existing equipments & circuits from old building to the new panel building will be done by contractor as per instructions of site engineer. Other telecom gears connection etc. (if required) and block instrument to Relay Room and connection with power supply will be done by the Contractor with Contractor's own material .

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-7

Page 13: RRU OUTDOORSCHEDULE

7 LOT 5 17855.33 89276.65

8 PER STN 5 3777.57 18887.85

9

Installation, wiring & Testing of Control cum Indication Panel, KLR boxes, Group phone, ELD, VHF & Test board, Auto change over panel etc. This includes laying & termination of cable, if any from Panel Room To Relay Room in GI/HDPE pipe. Note Important: All the S&T cables transists entries in PI, Equipment Room & Station Building, Control room, OFC hut/Shelters, Pota cabin, Cabinets (indoor & outdoor) shall be sealed with cement concrete mixture of 1:3:6 with contractors own material.Energisation of the system,making the panel through with contractors own mock panel in presence of Rly. Engineer. Soldering , lacing rosin core etc. required will be arranged by the contractor at his own cost. Panel should be covered with perplex sheet.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-11

Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material ("Asian" make enamel paints only to be used). This includes supply and fixing of Teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per extant practice on the division& instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-12a

Design and supply of Detailed Signalling Circuits including Panel diagram, Route section Plan, Selection Table along with SWR and correction slips for adjacent stations required for CRS sanction, Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any.

The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of circuits shall be placed in one polythene bag each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. He shall ensure that each sheet has a block for signature of Railway officials as well as a block for signature of the firm ,where signature shall be put by the circuit designer and authorised signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK Column. For small PI with Metal to Metal Relay.

Page 14: RRU OUTDOORSCHEDULE

(a) foryards of (40 domino x15 domino) panel size.LOT 5 81422.31 407111.55

(b) for LC GatePer LC 1 12136.25 12136.25

10

(a) For yards of (40 domino x15 domino) panel sizeLOT 5 28568.96 142844.8

(b) for LC GatePer LC 1 5842.28 5842.28

11

(a) Main signal foundation SK. No S&T/CONST/JHS/T/107 NO 80 9657.17 772573.6

(b) Shunt signal foundation SK. No S&T/CONST/JHS/T-109 NO 20 2017.17 40343.4

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-13a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-13b

Preparation of cable route plan, cable corage plan, location particulars, CT rack particulars, traction bonding diagram and any other drawing / particular required for PI in AutoCAD in A3 size. The contractor shall initially supply 2 sets of documents for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railways lterations/corrections/comments in the tracings & CD without any deviation and submit all tracings, Print in 4 sets & final CD complete in all respects to the Railways . He shall ensure that each sheet has a block for signature of Railway officials as well as a block for signature of the firm , duly signed by the authorised signatory of the firm. The name of the work as given by the Railways shall be written on every sheet under the WORK Column. (The contractor will design the coreage plan based upon the IP provided by Rlys. and present for approval)

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-17a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-17b

Excavation and casting of following signal foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-18a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-18b

Page 15: RRU OUTDOORSCHEDULE

12 Nos 80 3864.61 309168.8

13 Nos 20 553.79 11075.8

14 Nos 10 325.31 3253.1

15

(a) Single case as per Drg No S&T/CONST/JHS/T/112-A Nos 200 4324.83 864966

(b) Half case as per Drg No S&T/CONST/JHS/T/111-A Nos 30 3603.48 108104.4

16

(a) Single case Nos 200 1696.20 339240

(b) Half Case Nos 30 1356.74 40702.2

17 Nos 20000 11.96 239200

Erection of CLS Post with Surface base and signal unit on top or on Off set Bracket, fixing of front and back staging, ladder and guards including foundation of ladder, signal name plates/boards check nuts for signal base if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any on the same post. The work shall be done as per instructions of Rly engineer at site. This also includes supply & installation of 3 nos. hand cuff lock with their keys per signal. This includes Termination of tail cable on Main signal and auxillary units and wiring fixing of LED in units etc.with contractor own material, The work shall be done as per instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-19

Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No .plates. This includes termination of tail cable on Shunt signal units and wiring fixing of LED in units etc.with contractor own material.. This also includes supply & installation of 2 no. hand cuff lock with their keys per signal. The work shall be done as per instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-20

Fixing of Jn. Route Indication 1-Way/2-Way/3-Way on the top of the signal post.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-21

Excavation, casting and Erection of Apparatus case foundation and plastering with contractors own MS frame, cement, bricks and other materials. This includes filling of location foundations with river bed sand and plastering on top of the sand.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-25a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-25b

Fabrication and fixing of Hylam board in location box by providing all fixtures as per Railway practice including fixing of PVC coated 10mm string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-22a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-22b

Fixing of ARA Terminals and fuse blocks with provision of holes on hylem sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per the instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-23

Page 16: RRU OUTDOORSCHEDULE

18 25000 8.7 217500

19

(a) Single case Nos 150 1330.63 199594.50

(b) Half case Nos 10 975.94 9759.40

20 Nos 300 726.02 217806 JHS/S&T/C/Tender/10 dtd 27.02.08 Item no, B-48

21 750 123.82 92865 JHS/S&T/W-II/Tender/2010/03 Dt.29.07.11 B-22

22 Nos 350 544 190400

Termination of cable cores at both ends on ARA terminal/fuse blocks, 8 way terminals block in the apparatus cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

Per cable core

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-24

Installation of Eqpt. (Relays, resistance, chargers, bulb holders & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own wiring material suitable for 25KV RE area. This also includes supply & installation of Two pole switch & socket 5 A ( Anchor make ) Lamp Holders with lamp, two pin, Bakelite type with fixing arrangement at contractor own cost. The work shall be done as per instruction of Rly engineer at site and approval of wiring material ( from RDSO approved firms) being used and extant practice in the division.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-26 a

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-26 b

Fixing of earth electrodes, earthing of S & T appartus cases, signal post etc connected through GI wire 8 SWG supported on MS flat size 5mm x 40 mm to earth electrodes as per drg no,DRM/S&T/JHS/214 and practice on C. Rly. Suitable brick masonary enclosure to be provided around the earth. The earth value should be less than 10 ohms including the lead wire.. It should be measured and painted on it.

Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice on the division & the instruction of site engineer. The sulphuric acid & distilled water to be used for charging shall conform to specification IS 266-1961 & IS 1070-1960 respectively. (eah cell 80AH)

PER 100 VAH

Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material including angle of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for side connections. The work shall be done as per Drg. No. JHS/S&T/Wks-II/105 & instructions of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-27

Page 17: RRU OUTDOORSCHEDULE

23 Nos 1500 57.66 86490

24 PER T/O 35 3630.12 127054.2 JHS/S&T/C/Tender/08dtd 17.01.08 Item no, B-33

25 PER T/O 35 3630.12 127054.2 JHS/S&T/C/Tender/08dtd 17.01.08 Item no, B-34

26 Per T/o 25 10129.37 253234.25

Provision of bonding with GI wire/cable pieces for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site including supply of GI wire & channel Pins single groove, galvanized, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & 69/M with latest amendment. However cable pieces will be provided by Railways, if required.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-28

Removal of existing mechanical point fittings and FPL assembly from points,fixing of point machine,ground connection, adjustment and testing with crank handle for operation. Removal of ground connection,point machine after testing(duly numbered) and refixing of mechanical point fittings.This will include fabrication and fixing of bent pipes with welded frame for cable entry to the point machine and termination of the tail cable in point machine and wiring servicing of point machine & supply & filling of SAE 30 lubricating oil (500ml approx.) This also includes supply of all fixing material necessary fitting & adjustment to make the mechanically operated points functional again.(Ordinary layout/Derail switch/Double slip/Single slip) The work shall be done as per extant practice on NC Rly. & the instruction of Rly engineer at site.

Refixing of electrical point machine, ground connection during phase working (Non interlock working) after removing the mechanical fitting if any, adjustment if necessary, testing and commissioning of electricaly operated point, Fixing & connecting power supply & supply & filling of SAE 30 lubricating oil (500 ml approx).

Fixing of point machine on newly laid turnout on Wooden/MBC sleepers fixing of ground connections. Adjustment and testing with crank handle /electrical operations. This will include fabrication and fixing of bent pipes with welded frame for cable entry to the point machine and termination of tail cable in point machine and wiring servicing of point machine & supply & filling of SAE 30 lubricating oil (500 ml approx). This will also includes necessary adjustment and smithy work, drilling of Holes to tongue rails, fitting of insulation for tongue attachment, gauge plate & william stretcher. The work shall be done as per extant practice on NC. Rly & the instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-31

Page 18: RRU OUTDOORSCHEDULE

27 MTR 40000 38.08 1523200

28 MTR 2000 62.01 124020

29 MTR 800 2891.80 2313440

a.

b.30 MTR 700 100.09 70063

31 C/MTR 100 2632.38 263238 JHS/S&T/C/Tender/11 dt 18.06.2008 Item no.B-39

32 MTR 750 91.39 68542.5

Excavation of cable trench as per cable route plan,1 mt. deep and 300mm wide along side the track in all types of soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, placing of cable route marker, clearing of route, bushes etc. The work shall be done as per extant practice on the division & instruction of Rly engineer at site. In case depth of trench not achievable due to site conditions proportionate payment will be made.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-32

Excavation of cable trench as per cable route plan,1 mt. deep and 300mm wide along side the track in hard soil, Hard Morum, small stones & Bolders conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, placing of cable route marker, clearing of route, bushes etc. The work shall be done as per extant practice on the division & instruction of Rly engineer at site. In case depth of trench not achievable due to site conditions proportionate payment will be made .

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-33

Horizontal boring under Railway track / roads etc. for laying 120mm dia DWC (Double walled corrugated) pipes at the depth of 1.4 mtr to 2.1 mtrs from formation level (level of earth below ballast) as per drg. and directed by engineer incharge by trenchless technology excluding the cost of DWC pipes.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-36

The cost shall include horizontal boring through any intermediate obstruction, either natural or manmade or any boundary etc..

The rate is inclusive of all the materials, equipments and labour required for doing trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account other than the rates quoted above..

Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC pipes. The work shall be done as per extant practice on the division & instruction of Rly engineer at site

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-34

Cement concreting in 1:3:6 with contractor's own material including cement on specific instructions of site Engineer

Cutting of all types of road/platforms trenching & excavation to depth of 300 mm x 300mm wide approx. refilling after laying of RCC/GI/DWC pipes and reparing to restore to original condition.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-35

Page 19: RRU OUTDOORSCHEDULE

33 MTR 1000 87.12 87120 JHS/S&T/C/Tender/10 dtd 27.02.08 Item no, B-39

34 MTR 40000 15.23 609200

35 Nos 1250 11.45 14312.5

36 C/Mtr 100 179.02 17902

37 C/Mtr 30 8588.75 257662.5

38 KM 375 3437.02 1288882.5

39 SET 7 45227.48 316592.36

Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends. The GI Pipes has to be perforated at every 20 cms on four sides of pipe. All the necessary accessories required for fixing including clamp, nuts, bolts etc, at every 2M at girder bridge.The clamp will be of mild steel strips of 5 mm thick and 25 mm wide have to be provided by contractor at his own cost. All the fixing accessories to be hot deep galvanized before using. The work is required to be done as per the instruction of Rly engineer at site.Drg No. JHS/S&T/Wks-II/108

Supply and placing of well burnt second class bricks of size(225mm x 112mm x 75mm) inside the trench breadth wise after laying of cable in station area from home to home signal. Sample of bricks shall be got approved by engineer incharge before supply & laying. 9-10 bricks per meter shall be laid depending upon width of the bricks. In case the brick size is at variance with the size given in tender schedule then proportionate rates in Cubic Meter shall be given subject to the max rate of standard size.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-37

Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc.along the cable route.The work shall be done as per extant praciice on N.C.Rly. and as per drg.no. JHS/S&T/Wks-II/106 & instructions of Rly. Engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-44

Cross Trench for indentification of route of existing signalling and telecom cables in hard soil

CA No.S&T/NCR/JHS/13 dtd 12.08.2008 Item No. B-32

Cutting of rock & preparation of cable duct for laying of cable in rocky area and refilling the duct (after cable laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractor's own cement and other materials.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-48

Laying of signalling/Power/Telecom cable of various cores/sizes in trenches as per extant practice on the division & instruction of Rly engineer at site.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-38

Installation testing and commissioning of electrically operated lifting barrier, complete with casting of cement concrete foundation for pedestal and boom rest post as per standard drawing No DRM/S&T/JHS/38, cabling power supply connection & wiring with complete outdoor work including earthing of barriers.

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-39

Page 20: RRU OUTDOORSCHEDULE

40 1 2871.46 2871.46

41 5 15054.79 75273.95

42 Nos 30 367.36 11020.8

43 Nos 75 669.52 50214

44 1 5725.46 5725.46

45 5 22509.71 112548.55

46 50000 5.79 289500

47

Painting two coats of enamel paint over one coat of red coxide primer on all the new and existing signalling gears after scrapping and cleaning of the surface wherever necessary primer and paint both should be asian make to be supplied by contractor.The shall be done as per instraction of Railway engineer at site and extant practice on NC Rly .This also includes lettering /Numbering of signals,appratus cases and also termination particulars ,equipments name etc.

LOT / LC Gate

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-41

Painting two coats of enamel paint over one coat of Red Oxide primer on the location boxes, signal posts, base & unit, Glued & block joints, TLJB, point machine etc. following items after scrapping and cleaning of the surface wherever necessary. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases etc. Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. Primer and Paints both Asian paints make are to be supplied by Contractor. The work shall be done as per instructions of rly engineer at site and extant practice on the division.

LOT / STN

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-40

Fixing of Stop Board,BSLB,Goods warning board, Calling on board,MACLS board,Tokenless board etc. with contactors own material. The work shall be done as per DRg. No. JHS/S&T/Wks-II/104 and instructions of Rly Engineer at site.

JHS/S&T/C/Tender/08dtd 27.02.2008 Item no, B-22

Jointing of S&T cables with heat Shrinkable Straight through Jointing kit TSF-3 for S&T Cables.

JHS/S&T/W-II/Tender/ 2010/03 dated 29.07.2011 Item No. B-34

Releasing of , lever frame , old location boxes, signal posts, equipment inside the location boxes & lifting barrier including the breaking of foundation as per the instruction of Rly engineer at site & their transportation to SSE incharge at depot.(from Level crossing gates)

LOT / LC Gate

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-43

Releasing of signal posts, Ground frame, point rodding, wire run, pulley stakes, lifting barrier & other S&T gears including the breaking of foundation as per the instruction of Rly engineer at site & their transportation to SSE incharge at depot.

LOT / STN

JHS/N/W/16/ 11/4PI, 1MACL & 2LC/ BNDA-BZM dtd .19.01.2012 Item No. B-42

Carriage by truck of various railway materials including loading, unloading, and staking operations operation & Stalling at specific depots/locations from any station to any other station/Location to Jhansi and other stations of Jhansi Division with all contractors labour,tools,machinery etc. complete job as directed bt engineer in charge.(Av lead 120 Kms.)

Per MT Per Km

Tender No JHS/Engg/2011/02 C Dated 12.01.2011 Item no NS-3

Hiring of one four wheeler commercial multi-utility inspection vehicle minimum 1+6 seater design Tavera/Scorpio/Innova/ Xylo or similar in perfectly good condition for daily 12 hours availability at JHS/BNDA/MKP /CKTD stations or as specified by railway representative.

As per quotation of M/s VIP TOURS & TRAVELS Sipri Jhansi Dated 18.07.2013

Page 21: RRU OUTDOORSCHEDULE

(a) Cost of hiring of vehicle including fuel cost for running upto 200 Kms 300 2200 660000

(b) Beyond 200 Kms Per Km 8000 10 80000

TOTAL OF SCHEDULE B 13991326.13TOTAL OF SCHEDULE A 52573689.421TOTAL OF SCHEDULE A+B 66565015.55

Per day/per vehicle

Page 22: RRU OUTDOORSCHEDULE

LIST OF SCAFFOLDING MATERIALS FOR RELAY RACK.

SNO DESCRIPTION SIZE ** UNIT QTY1 Relay rack with fixtures and spacer. NOS 122 IDF piller with fixtures. NOS 123 Top frame angle for 2 Relay racks. 65x65x1140mm NOS 64 Bottom frame angle for 2 Relay racks. 65x65x1140mm NOS 65 Top frame angle for 2 Relay racks. 65x65x1780mm NOS 66 Bottom frame angle for 2 Relay racks. 65x65x1780mm NOS 67 IDF Bottom angle for 9 pillers. 65x65x1780mm NOS 18 IDF Top angle for 9 pillers. 65x65x1780mm NOS 19 IDF Bottom angle for 6 pillers. 65x65x1140mm NOS 1

10 IDF Top angle for 6 pillers. 65x65x1140mm NOS 111 Vertical support angle RH. Suitable size NOS 412 Vertical support angle LH. Suitable size NOS 413 Triangle Base assembly with ' J ' Bolts, nuts, Suitable size NOS 36

flat and spring washers.14 Insulaters with fixing studs, spring and flat stud - 12x25mm & NOS 72

washers (one stud each for one insulater). 12x20mm. NOS 4815 Cable support assembly i.e. ' L' Bracket with 8 x 25mm, NOS 24

4Nos. of bolts with nut, spring and plain 6 x 50mm NOS 24washers for each ' L' Bracket.

16 16-way fuse holders (1.6A/0.6A) mounting NOS 48stripes with studs, spring and plain washers.

17 Bracket for mounting 16-way/8-way fuse Suitable size SET 12stripes with nuts,bolts and washers, i.e.(top brackets) All angles & stripes shall be

6mm and 5mm thick respectively.18 Bracket for mounting 16-way fuse stripes Suitable size SET 4

(i.e.bottom bracket).19 Cable supporting stripes 5 x 20 x 210mm NOS 6020 Cable supporting stripes 5 x 20 x 150mm NOS 6021 String rod with PVC insulation (sleeve) Suitable size NOS 110

fixing bracket and stud with spring and plain washers.

22 11-way Bus bar with 16 sq.mm lugs with NOS 12PVC covers & fixing arrangement (Bracketfor fixing Bus bar cover) nut & bolts.

23 Square bar for fixing 8 nos. of mini group Suitable size NOS 120base plate.

24 PVC sleeve (Tube) for insulating wire run 16mm/20mm MTRS 80support on IDF pillars and at other places,U clamps etc.

25 Angle of various sizes for frame wall supportand cable run support (interspacing betweenracks) (All angles of 6mm thick).a) Angle 65 x 65 x 2000mm NOS 6b) Angle. 40 x 40 x 2000mm NOS 6c) Angle 40 x 40 x 1325mm NOS 6d) Angle. 40 x 40 x 1000mm NOS 15

Page 23: RRU OUTDOORSCHEDULE

e) Angle. 65 x 65 x 1000mm NOS 626 Angle pieces for fixing wall support angles

with 'J' bolts, Nuts, springs and plain washershaving 13mm holes and 8mm holes.(a) Angle piece with 23mm holes at both 65 x 65 x 50 NOS 6 65mm side(b) Angle piece with one hole 13mm and 40 x 40 x 35 NOS 20 other 9mm on 40mm side

27 Cable support 'U' bracket 540 x 100mm NOS 2428 C' Bracket for cable run support(5mm thick) 200 x 200mm NOS 32

20mm width MS flat to be used.29 C' Bracket for cable run support 5mm thick 200 x 150mm x20mm NOS 50

MS flat to be used width.30 Signal resistance mounting assembly Suitable size SET 9

complete with fixtures and fasteners.31 Guide rails with fixtures and fasteners for: a) Route group Suitable size NOS 6

b) Point group Suitable size NOS 6c) Main signal group Suitable size NOS 8d) Shunt signal group Suitable size NOS 6

32 MS Flat strip for mounting AG timers Suitable size SET 833 Resistance and condenser mounting assem- Suitable size

bly Qty. and size as per circuit requirements.34 Anodized nuts and bolts with plain and

spring washers.a) 'J' Bolts for fixing square bars. Suitable size NOS 150b) Studs for fixing relay base plate. 4 x 20mm NOS 2000c) Bolts with nuts. 6 x 20mm NOS 70d) Bolts with nuts. 6 x 25mm NOS 150e) Bolts with nuts. 6 x 40mm NOS 100f) Bolts with nuts. 6 x 50mm NOS 60

g) Bolts with nuts. 6 x 75mm NOS 50h) Bolts with nuts. 8 x 25mm NOS 50i) Bolts with nuts. 12 x 25mm NOS 30

35 Rack joining pieces. Suitable size NOS 1036 Ladder for cable run support and power

wiring with ladder joining pieces and boltswith nuts and washers.

a) 400 x 1500mm. 40 x 40 x 6mm NOS 20b) 200 x 1500mm. 25 x 25 x 5mm NOS 20b) 150 x 1500mm. 25 x 25 x 3mm NOS 25

37 Blue colour PVC sleeve. 2.5mm MTRS 80

38 Suitable size NOS 130

39 Suitable size NOS 15

40 Fuse Holder with inserts of different capacity 0.6/1.6/10A NOS 775NOTE:

C bracket for fixing relay nomenclature strips alongwith fixing nuts,bolts & screws.

Relay rack designation board, L shape complete with fixing clamps.

Page 24: RRU OUTDOORSCHEDULE

** Dimensions/ Supporting angles to be modified to suit the condition.Cotractor has to supply any other item/ items required for complete erection of relay rack other than listed above or variation in quantity (more/less) shall be supplied as per site requirement free of cost.Requirement of fuse holder and inserts will be as per circuit + spares.

Page 25: RRU OUTDOORSCHEDULE

LIST OF SCAFFOLDING MATERIALS FOR CABLE TERMINATION RACK

S.N. DESCRIPTION SIZE UNIT QTY1 Nos 1

2 65 X 65 X 1104mm Nos 1

3 65 X 65 X 1104mm Nos 1

4 Vertical support angle RH. 6mm thickx65x65 Nos 15 Vertical support angle LH. 6mm thickx65x65 Nos 16 Suitable size Nos 4

7 12mmx20mm Nos 8

8 12mm x 25mm Nos 8

9 Suitable size Nos 4

10 Cable support stripes ('U') i.e. 'U' Bracket. 540mmx5mmx6mm Nos 4

11 Cable supporting stripes with fasteners. 5mmx20mmx150mm Nos 16

12 Suitable size Nos 20

13 Suitable size Nos 16

14 Nos 4

15 500mm x 2000mm Nos 4

16 400mmx1500mm Nos 4

17 Formica sheets with white colour. 3x1200x2400mm Nos 1

18 Angle for wall support Nos 2

19

20 Tag block 96 way with cover Nos 12

C.T. rack complete with all fixtures, fasteners and spacers.Top frame angle for C.T. rack (2 way) 6mm thick. Bottom frame angle for relay rack (2 way) 6mm thick

Triangle base assembly with 'J' Bolts, Nuts,Spring & plain washer.Insulators with two studs each with flat and spring washers.Insulators with two studs each with flat and spring washers.L' Bracket i.e cable support assembly complete with fixtures and fasteners.

String rods with fixing bracket and fasteners complete with PVC insulations.Square bars for fixing 8-way terminal block, 4nos. on each bar, complete with studs for fixing 8-way terminal blocks,nuts, bolts, flat and spring washers for fixing square bars.

Angles for wall support complete with angle piece 'J' bolts, bolts with nuts, plain and spring washers.

40x40x1000mm 6mm thick

Ladder for outdoor cable support made of 40x40x6mm angle.Ladder for indoor cable run support made of 40x40x6mm angle.

40 x 40 x 2000mm (6mm thick)

Any other materials required for erection of C.T. Rack.

Page 26: RRU OUTDOORSCHEDULE
Page 27: RRU OUTDOORSCHEDULE

Annexure for DataloggerSN Description Unit Qty

1 Datalogger having 512 digital input & 32 Analog input Nos. 1

2 Leased line modem for networking Set 1

3 CMU as per following details with minimum specifications as per following

Nos. 1

(I) Intel core i7-860 2.8GHz,8 MB cache or latest Nos. 1

(II) 2 GB SDRAM or higher for latest OS and application software Nos. 1

(III) 500 GB HDD (7200 rpm) Nos. 1

(IV) 22" TFT colour monitor Nos. 1

(V) Onboard Sound card with speakers Nos. 1

(VI) Inbuilt 56 kbps modem Nos. 1

(VII) Multimedia keyboard(USB), mouse(USB Optical), 10/100 T LAN card. Nos. 1

(VIII) DVD writer,Dual Gigabit Ethernet ports & 2 serial ports. Nos. 1

4 The requisite peripherals with software should be as follows:(I) UPS APC / Emerson/Numeric make 1KVA with 30 minutes backup time Nos. 1

(II) Multi functional (print, scan, copy, fax) HP Printer or higher (HP make) Nos. 1

(III) Pen drive (USB drive) 8 GB or higher Nos. 2

(IV) Nos. 1

5 Nos. 1

6 Software for fault analyser Set 1

7 Software for network Set 1

It should be of HP/IBM/DELL make working on commercial supply of 230V AC, 50 Hz with minimum three years on site warranty as per minimum configuration detailed below :

Licensed software version of Windows XP or latest with latest version of Kaspersky Antivirus and Windows 7 Proffesional OS or better,valid for 03 years.

Operator chair Godrej PCH 7001, ComputerTable model T 102 Godrej make or similar of Godrej only

Note:- The quantity mentioned for computer items is for one PC

Page 28: RRU OUTDOORSCHEDULE

ANNEXURELIST OF ITEMS REQUIRED IN TOOL KIT

S.No. Description Make Size Unit Qty1 Insulated flat plier. Taparia / Jhalani 125mm Nos 22 Insulated side cutting Taparia / Jhalani 6" Nos 23 Insulated stripping plier Taparia / Jhalani 150mm Nos 24 Insulated noseplier Taparia / Jhalani 150mm Nos 25 Screw Driver (Insulated) set Taparia / Jhalani Set of 6 Set 16 Screw Driver (Insulated) Taparia / Jhalani 250 X 8mm Nos 17 Screw Driver (Insulated) Taparia / Jhalani 250 X 10mm Nos 18 Flat coarse file with handle Bosh or similar 150mm Nos 19 Round Fine file with handle Bosh or similar 150mm Nos 1

10 Hammer with handle Bosh or similar 500Gms Nos 211 Spanner Double ended. Taparia / Jhalani 6-32 mm Set 112 Ring Spanner Double ended Taparia / Jhalani 6-32 mm Set 113 Hack Saw frame with 6 blades Bosh or similar 6" Nos 114 Hack Saw frame with 6 blades Bosh or similar 12" Nos 115 Measuring tape Freeman Make 3 Mt. Nos 216 Measuring tape Freeman Make 30 Mt. Nos 217 Easy clean vacuum cleaner Eureka Forbes Make Nos 118 Adjustable screw wrench Taparia 12" Nos 219 Adjustable screw wrench Taparia / Jhalani / Gedore / Everest 15" Nos 220 Soldering iron230V Kleetrone / Soldron 100 w Nos 221 Soldering iron230V Kleetrone / Soldron 50 w Nos 222 Box spanner set Taparia / Jhalani / Gedore / Everest 5-10mm Set 123 Box spanner for OBA terminals Taparia / Jhalani / Gedore / Everest 12 mm Nos 2

24 DMM 4 1/2 digit Motwane DMM 104 model 4.5 Digit Nos 325 Megger - 500V Motwane make D20K model 500 v Nos 226 Megger - 100V Motwane make D2K-M model 100 v Nos 227 Toolbox Briefcase type with lock Nos 128 Crimping tool 3D make CAT no.3D-3 or equivalent Nos 129 Digital Clamp meter Motwane DCM 49 A (AC/DC) Nos 130 Vernier Caliper Bosh or similar 150mm Nos 131 Pen drive Sandisc make (Latest) 8 GB Nos 432 Standard wire guage Bosh or similar Nos 133 Drill bit (7.1mm dia) Miranda or better 7.1mm Nos 2034 Electric hand drill machine 230v AC Wolf make or similar 0 - 10 mm Nos 135 Electric saw machine (Portable) Wolf make or similar Nos 136 Brass Padlock Godrej make 50 mm Nos 437 L.E.D. Torch Eveready make or similar Large Nos 238 Citizen make CT 500 Nos 2

39 Electric Extension cord Anchor make or similar 10 Mt. Nos 240 Digital Earth Tester Motwane DET 20 model Nos 1

Digital Calculator (Check & correct) 12 digits with dual power

Page 29: RRU OUTDOORSCHEDULE

PROVISION OF PPTC FUSES FOR ONE STATION (BNDA-MKP SEC.)

Sr.No. Description of Fuse Quantity Rate Amount Remarks

1 FRU 250-30F 10 8.00 80 SSDAC,EJB

2 FRU 090-30F 200 5.92 1184

3 FRU 600-30F 200 14.3 2860 BUS BAR

4 FRX 065-60F 20 7.30 146 POINT

5 FRX 090-60F 20 7.70 154 KLCR

6 FRK 500-60F 100 20.90 2090 BUS BAR 60V

7 FHT 100-30F 100 13.00 1300 MISC

8 FRG 250-16F 50 8.70 435 TRACK FEED

8249

Approx Instt. Charges + Profit 1655

Total 9904

TPR,N/RWKR,XCKR,CHKR,HPR/DPR